W912QR25R0027_CID-0002.pdf
PDF 2 MB Posted
- Solicitation number
- W912QR25R0027
About this file
This document is a Certified Final Submittal for Furniture Fixtures and Equipment (FF&E) and Flooring Design for the Wright-Patterson Air Force Base Research Facility Renovation project, issued by the US Army Corps of Engineers Louisville District. The submittal details interior design specifications for workstations and flooring, focusing on two primary areas:
Workstation Design: The document specifies 4-person workstations (2 units in Room 369) featuring 72"x72" and 78"x66" configurations with tackable fabric panels, laminate surfaces with PVC edge bands, painted metal storage, and accessories. Flooring specifications include multiple carpet tile types from J&J Flooring's Non Fiction II line, with various colors (Glossary, Dialogue, Lexicon) in 24"x24" tiles, some installed on raised access flooring with modular carpet connectors. Additionally, the design includes sealed concrete flooring (SC-1) in certain areas. The project is associated with contract number USACE Louisville District P2 Number 496691 and is dated 16 JUN 2025, indicating a planned renovation of a research facility for Modeling, Simulation, and Analysis (MS&A).
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LAMINATE
TOP
PAINT
FINISH
PANEL
FABRIC
FINISH SELECTION IS BASIS OF DESIGN,
CAN CHOOSE FROM MANUFACTURER'S
FULL LINE OF FINISHES.
THESE DRAWINGS ARE PROPERTY OF CEMS ENGINEERING, INC. AND MAY NOT BE REPRODUCED IN ANY MANNER WITHOUT WRITTEN CONSENT.
PROJECT:
CONTRACT:
SUBMITTAL:
DATE:
US Army Corps of Engineers ®
BASIS OF DESIGN AND FINISHES
WRIGHT-PATTERSON AIR FORCE BASE
RENOVATE RESEARCH FACILITY FOR MS&A-F20145
USACE LOUISVILLE DISTRICT P2 NUMBER 496691
CERTIFIED FINAL SUBMITTAL
16 JUN 2025
FURNITURE FIXTURES AND EQUIPMENT: WS-11
ROOM LOCATIONS AND ROOM QUANTITIES
DESCRIPTION FINISH COMMENTS QTY.
4 PERSON WORKSTATION , (3) 72"x72" (1) 78"x66", TACKABLE FABRIC PANELS, LAMINATE SURFACE WITH
PVC EDGE BAND, PAINTED METAL STORAGE AND
ACCESSORIES
FABRIC PANELS,
LAMINATE SURFACE,
PVC EDGEBAND,
METAL TRIM AND
STORAGE
ROOM QTY
369 2
W912QR25R0027_CID-0002
FINISH TYPE:
MANUFACTURER:
MATERIAL:
COLOR:
SIZE:
COMMENTS:
STYLE:
J&J FLOORING
FLOORING
CARPET TILE
7026/3001 GLOSSARY
CPT-1
24" X 24"
QUARTER TURN
NON FICTION II
FINISH TYPE:
MANUFACTURER:
MATERIAL:
COLOR:
SIZE:
COMMENTS:
STYLE:
J&J FLOORING
FLOORING
CARPET TILE
7025/1785 DIALOGUE
CPT-2
24" X 24"
QUARTER TURN
NON FICTION II
FINISH TYPE:
MANUFACTURER:
MATERIAL:
COLOR:
SIZE:
COMMENTS:
STYLE:
FLOORING
SEALED CONCRETE
SC-1
CLEANED, PREPARED, SEALED
THESE DRAWINGS ARE PROPERTY OF CEMS ENGINEERING, INC. AND MAY NOT BE REPRODUCED IN ANY MANNER WITHOUT WRITTEN CONSENT.
PROJECT:
CONTRACT:
SUBMITTAL:
DATE:
US Army Corps of Engineers ®
WRIGHT-PATTERSON AIR FORCE BASE
RENOVATE RESEARCH FACILITY FOR MS&A-F20145
USACE LOUISVILLE DISTRICT P2 NUMBER 496691
CERTIFIED FINAL SUBMITTAL
16 JUN 2025
STRUCTURAL INTERIOR DESIGN: FLOORING W912QR25R0027_CID-0002
FINISH TYPE:
MANUFACTURER:
MATERIAL:
COLOR:
SIZE:
COMMENTS:
STYLE:
J&J FLOORING
FLOORING
CARPET TILE
7025/3346 LEXICON
CPT-6
24" X 24"
INSTALLED ON RAISED ACCESS
FLOORING, TILE TABS MODULAR CARPET
CONNECTORS, QUARTER TURN
NON FICTION II
FINISH TYPE:
MANUFACTURER:
MATERIAL:
COLOR:
SIZE:
COMMENTS:
STYLE:
J&J FLOORING
FLOORING
CARPET TILE
7025/1785 DIALOGUE
CPT-5
24" X 24"
INSTALLED ON RAISED ACCESS
FLOORING, TILE TABS MODULAR CARPET
CONNECTORS, QUARTER TURN
NON FICTION II
FINISH TYPE:
MANUFACTURER:
MATERIAL:
COLOR:
SIZE:
COMMENTS:
STYLE:
J&J FLOORING
FLOORING
CARPET TILE
7026/3001 GLOSSARY
CPT-4
24" X 24"
INSTALLED ON RAISED ACCESS
FLOORING, TILE TABS MODULAR CARPET
CONNECTORS, QUARTER TURN
NON FICTION II
FINISH TYPE:
MANUFACTURER:
MATERIAL:
COLOR:
SIZE:
COMMENTS:
STYLE:
J&J FLOORING
FLOORING
CARPET TILE
7025/3346 LEXICON
CPT-3
24" X 24"
QUARTER TURN
NON FICTION II
THESE DRAWINGS ARE PROPERTY OF CEMS ENGINEERING, INC. AND MAY NOT BE REPRODUCED IN ANY MANNER WITHOUT WRITTEN CONSENT.
PROJECT:
CONTRACT:
SUBMITTAL:
DATE:
US Army Corps of Engineers ®
WRIGHT-PATTERSON AIR FORCE BASE
RENOVATE RESEARCH FACILITY FOR MS&A-F20145
USACE LOUISVILLE DISTRICT P2 NUMBER 496691
CERTIFIED FINAL SUBMITTAL
16 JUN 2025
STRUCTURAL INTERIOR DESIGN: FLOORING W912QR25R0027_CID-0002
| Sheets |
| FF&E - 5.43A - WS-11 |
| SID - 4.1 - FLOORING |
| SID - 4.2 - FLOORING |
File details come from the government source that posted it. Updated .