W912QR20R0004_Plans_Vol_IV-0000.pdf
PDF 34 MB Posted
- Solicitation number
- W912QR20R0004
About this file
This document provides details on a federal solicitation for the Joint Operations Mission and Planning Center (JOMPC) at Scott Air Force Base. The solicitation number is W912QR20R0004 and was issued by the Department of the Army Corps of Engineers Engineering District Louisville. Interested parties should review the attached solicitation document and previously posted pre-solicitation notice for requirements regarding the JOMPC project. The solicitation seeks proposals for construction of the JOMPC and includes relevant details such as response dates, award timing, and the federal agency overseeing the opportunity.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
P
L O
T D
A T
E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C
O N
T R
A C
T N
O
A F
D R
A W
IN
G
C O
D E
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
SHEET ID
P R
O J E
C T
N O
K
R S
M
S C
O T
T A
IR
F
O R
C E
B A
S E
IL
L
IN
O
IS
J O
IN
T
O P
E R
A T
IO
N
S
M
IS
S
IO
N P
L A
N N
IN
G
C E
N T
(J
M
P C
A S
S H
O W
N
C E
R T
IF
IE
D F
IN
A
L
IS
S
U E
D F
O R
B
ID
1 753 92 864 10
A
B
C
D
E
F
G
/1
/2
V D
Y D
G-007
C L O
U D
O N
J .B
R
IC
E
/1
/2
P ro je c t N u m b e rG
-0 .D
W G
C O
V E
R V
O L U
M E
I V
US Army Corps of Engineers ®
9400 WARD PARKWAY
KANSAS CITY, MO 64114
P2 NUMBER: 476084
JOINT OPERATIONS & MISSION PLANNING CENTER (JOMPC)
LOUISVILLE DISTRICT
SCOTT AIR FORCE BASE, ILLINOIS
PROJECT NUMBER: VDYD1055428
VOLUME IV
ISSUED DATE: DECEMBER 11, 2020
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
C
E R
T
IF
IE
D
F
IN
A L
I S
S U
E D
F O
R B
ID
D
E C
11 DEC 2020
CONTROLLED UNCLASSIFIED INFORMATION
CONTROLLED UNCLASSIFIED INFORMATION
08 March 2021
W912QR20R0004
ARIMS: 200A Disposition: Maintain for 15 yrs after construction
W
2Q R
R
_P la ns _V ol _I
V-
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
P
L O
T D
A T
E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C
O N
T R
A C
T N
O
A F
D R
A W
IN
G
C O
D E
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
SHEET ID
P R
O J E
C T
N O
K
R S
M
S C
O T
T A
IR
F
O R
C E
B A
S E
IL
L
IN
O
IS
J O
IN
T
O P
E R
A T
IO
N
S
M
IS
S
IO
N P
L A
N N
IN
G
C E
N T
M
P C
A S
S H
O W
N
C E
R T
IF
IE
D F
IN
A
L
IS
S
U E
D F
O R
B
ID
1 753 92 864 10
A
B
C
D
E
F
G
/1
/2
V D
Y D
G-008
C L O
U D
O N
J .B
R
IC
E
/1
/2
P ro je c t N u m b e rG
-0 .D
W G
S H
E E
T I
N D
E X
V
O L U
M E
I V
ELECTRICAL SHEET LIST
EP602 ONE LINE DIAGRAMS
EP603 ONE LINE DIAGRAMS
EP604 ONE LINE DIAGRAMS
EP605 ONE-LINE CONDUCTOR TABLES
EP700 PANELBOARD SCHEDULE
EP701 PANELBOARD SCHEDULE
EP702 PANELBOARD SCHEDULE
EP703 PANELBOARD SCHEDULE
EP704 PANELBOARD SCHEDULE
EP705 PANELBOARD SCHEDULE
EP706 PANELBOARD SCHEDULE
EP707 PANELBOARD SCHEDULE
EP708 PANELBOARD SCHEDULE
EP709 PANELBOARD SCHEDULE
EP710 PANELBOARD SCHEDULE
EP711 PANELBOARD SCHEDULE
EP712 PANELBOARD SCHEDULE
EP713 PANELBOARD SCHEDULE
EP714 PANELBOARD SCHEDULE
EP715 PANELBOARD SCHEDULE
EP716 PANELBOARD SCHEDULE
EP717 PANELBOARD SCHEDULE
EP718 PANELBOARD SCHEDULE
EP719 PANELBOARD SCHEDULE
EP720 PANELBOARD SCHEDULE
EP721 PANELBOARD SCHEDULE
EP722 PANELBOARD SCHEDULE
EP723 PANELBOARD SCHEDULE
EP724 PANELBOARD SCHEDULE
EP725 PANELBOARD SCHEDULE
EP726 PANELBOARD SCHEDULE
EP727 PANELBOARD SCHEDULE
EP728 PANELBOARD SCHEDULE
EP729 PANELBOARD SCHEDULE
EP730 MECHANICAL EQUIPMENT CONNECTION SCHEDULE
EG101 FIRST FLOOR OVERALL GROUNDING PLAN
EG102 SECOND FLOOR OVERALL GROUNDING PLAN
EG103 LIGHTNING PROTECTION SYSTEM ROOF PLAN
EG501 GROUNDING DETAILS
EG502 GROUNDING DETAILS
EG503 TELECOMMUNICATIONS GROUNDING DETAILS
EG504 TELECOMMUNICATIONS GROUNDING DETAILS
EG601 GROUNDING RISER DIAGRAM
EG602 GROUNDING RISER DIAGRAM
EG603 TELECOMMUNICATIONS GROUNDING RISER DIAGRAM
Grand total: 153
ELECTRICAL SHEET LIST
E-001 ELECTRICAL LEGEND 1 OF 2
E-002 ELECTRICAL LEGEND 2 OF 2
ES100 OVERALL ELECTRICAL SITE PLAN
ES102 ELECTRICAL SITE PLAN 2
ES102A ELECTRICAL SITE PLAN 2 - OPTION
ES103 ELECTRICAL SITE PLAN 3
ES103A ELECTRICAL SITE PLAN 3 - OPTION
ES104 ELECTRICAL SITE PLAN 4
ES105 ELECTRICAL SITE PLAN 5
ES106 ELECTRICAL SITE PLAN 6
ES107 ELECTRICAL SITE PLAN 7
ES108 ELECTRICAL SITE PLAN 8
ES109 ELECTRICAL SITE PLAN 9
ES110 ELECTRICAL SITE PLAN 10
ES114 ELECTRICAL SITE PLAN 14
ES501 ELECTRICAL SITE DETAILS
ES502 ELECTRICAL SITE DETAILS
ES503 ELECTRICAL SITE DETAILS
ES504 ELECTRICAL SITE DETAILS
EL101 LIGHTING PLAN LEVEL 1 - AREA A
EL102 LIGHTING PLAN LEVEL 1 - AREA B
EL103 LIGHTING PLAN LEVEL 1 - AREA C
EL104 LIGHTING PLAN LEVEL 1 - AREA D
EL105 LIGHTING PLAN LEVEL 1 - AREA E
EL106 LIGHTING PLAN LEVEL 1 - AREA F
EL107 LIGHTING PLAN LEVEL 1 - AREA G
EL108 LIGHTING PLAN LEVEL 1 - AREA H
EL109 LIGHTING PLAN LEVEL 2 - AREA A
EL110 LIGHTING PLAN LEVEL 2 - AREA B
EL111 LIGHTING PLAN LEVEL 2 - AREA C
EL112 LIGHTING PLAN LEVEL 2 - AREA D
EL113 LIGHTING PLAN LEVEL 2 - AREA E
EL114 LIGHTING PLAN LEVEL 2 - AREA F
EL121 BLUE LIGHTING COVERAGE PLAN LEVEL 1 - AREA A
EL122 BLUE LIGHTING COVERAGE PLAN LEVEL 1 - AREA B
EL123 BLUE LIGHTING COVERAGE PLAN LEVEL 1 - AREA C
EL124 BLUE LIGHTING COVERAGE PLAN LEVEL 1 - AREA D
EL125 BLUE LIGHTING COVERAGE PLAN LEVEL 1 - AREA E
EL126 BLUE LIGHTING COVERAGE PLAN LEVEL 1 - AREA F
EL127 BLUE LIGHTING COVERAGE PLAN LEVEL 2 - AREA A
EL128 BLUE LIGHTING COVERAGE PLAN LEVEL 2 - AREA B
EL129 BLUE LIGHTING COVERAGE PLAN LEVEL 2 - AREA C
EL130 BLUE LIGHTING COVERAGE PLAN LEVEL 2 - AREA D
EL131 BLUE LIGHTING COVERAGE PLAN LEVEL 2 - AREA E
EL132 BLUE LIGHTING COVERAGE PLAN LEVEL 2 - AREA F
EL201 LIGHTING ELEVATION
EL202 LIGHTING ELEVATION
EL203 LIGHTING ELEVATION
EL204 LIGHTING ELEVATION
EL205 LIGHTING ELEVATION
EL401 LIGHTING ENLARGED PLAN
EL402 LIGHTING ENLARGED PLAN
EL501 LIGHTING DETAILS
EL502 LIGHTING DETAILS
EL503 LIGHTING DETAILS
EL504 LIGHTING DETAILS
EL505 LIGHTING DETAILS
EL506 LIGHTING DETAILS
EL507 LIGHTING DETAILS
EL601 LIGHTING SCHEDULES
EL602 LIGHTING CONTROL MATRIX
EP101 POWER PLAN LEVEL 1 - AREA A
EP102 POWER PLAN LEVEL 1 - AREA B
EP103 POWER PLAN LEVEL 1 - AREA C
EP104 POWER PLAN LEVEL 1 - AREA D
EP105 POWER PLAN LEVEL 1 - AREA E
EP106 POWER PLAN LEVEL 1 - AREA F
EP107 POWER PLAN LEVEL 1 - AREA G
EP108 POWER PLAN LEVEL 1 - AREA H
EP109 POWER PLAN LEVEL 2 - AREA A
EP110 POWER PLAN LEVEL 2 - AREA B
EP111 POWER PLAN LEVEL 2 - AREA C
EP112 POWER PLAN LEVEL 2 - AREA D
EP113 POWER PLAN LEVEL 2 - AREA E
EP114 POWER PLAN LEVEL 2 - AREA F
EP121 HVAC POWER PLAN LEVEL 1 - AREA A
EP122 HVAC POWER PLAN LEVEL 1 - AREA B
EP123 HVAC POWER PLAN LEVEL 1 - AREA C
EP124 HVAC POWER PLAN LEVEL 1 - AREA D
EP125 HVAC POWER PLAN LEVEL 1 - AREA E
EP126 HVAC POWER PLAN LEVEL 1 - AREA F
EP127 HVAC POWER PLAN LEVEL 1 - AREA G
EP128 HVAC POWER PLAN LEVEL 1 - AREA H
EP129 HVAC POWER PLAN LEVEL 2 - AREA A
EP130 HVAC POWER PLAN LEVEL 2 - AREA B
EP131 HVAC POWER PLAN LEVEL 2 - AREA C
EP132 HVAC POWER PLAN LEVEL 2 - AREA D
EP133 HVAC POWER PLAN LEVEL 2 - AREA E
EP134 HVAC POWER PLAN LEVEL 2 - AREA F
EP201 POWER ELEVATIONS
EP202 POWER ELEVATIONS
EP203 POWER ELEVATIONS
EP204 POWER ELEVATIONS
EP205 POWER ELEVATIONS
EP401 POWER ENLARGED PLAN
EP402 POWER ENLARGED PLAN
EP403 POWER ENLARGED PLANS
EP404 POWER ENLARGED PLANS
EP405 POWER ENLARGED PLAN
EP406 POWER ENLARGED PLANS
EP407 POWER ENLARGED PLANS
EP408 POWER ENLARGED PLAN
EP409 POWER ENLARGED PLAN
EP410 POWER ENLARGED PLAN
EP501 ELECTRICAL DETAILS
EP502 ELECTRICAL DETAILS
EP503 ELECTRICAL DETAILS
EP601 ONE LINE DIAGRAMS
VOLUME IV
GENERAL SHEET INDEX - VOUME IV
SHEET NUMBER SHEET TITLE
G-007 COVER VOLUME IV
G-008 SHEET INDEX - VOLUME IV
CONTRACTORS ARE FREE TO USE ANY PRODUCT WHICH MEETS THE
GOVERNMENT'S MINIMUM REQUIREMENTS AND NOT IN CONFLICT WITH OTHER
CONTRACT PROVISIONS. UNLESS INDICATED OTHERWISE ON THE PLANS OR
SPECIFICATIONS (E.G. SOLE-SOURCE), ALL LISTED MANUFACTURERS ARE THE
BASIS OF DESIGN. FOR THESE BASIS OF DESIGN PRODUCTS, OTHER
MANUFACTURERS MAY BE SUBSTITUTED AS LONG AS THE STANDARD OF QUALITY
AND CHARACTERISTICS OF THE SUBSTITUTED MANUFACTURER MEET OR EXCEED
THE STANDARD OF QUALITY AND CHARACTERISTICS OF THE BASIS OF DESIGN.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
C
E R
T
IF
IE
D
F
IN
A L
I S
S U
E D
F O
R B
ID
D
E C
CONTROLLED UNCLASSIFIED INFORMATION
CONTROLLED UNCLASSIFIED INFORMATION
ARIMS: 200A Disposition: Maintain for 15 yrs after construction
W
2Q R
R
_P la ns _V ol _I
V-
SYMBOLS - LIGHTINGSYMBOLS - POWER
CONNECTION
CONTINUATION
SEPARABLE CONNECTOR OR CONNECTION
FOR DRAWOUT ASSEMBLIES
FUSED DISCONNECT SWITCH
TRANSFORMER
GROUND
DELTA - WYE TRANSFORMER CONNECTION
DIGITAL METER
SURGE PROTECTIVE DEVICE
VARIABLE FREQUENCY DRIVE
SHUNT TRIP
KILOWATT HOUR METER
VOLTMETER SELECTOR SWITCH
AMMETER SELECTOR SWITCH
VOLTMETER
AMMETER
CIRCUIT BREAKER
SWITCH
DISCONNECT SWITCH
SPECIAL RECEPTACLE
PANELBOARD (PANELBOARD NAMED 'M')
LIGHTNING ARRESTOR
AUTOMATIC OR MANUAL TRANSFER SWITCH
MULTI-FUNCTION DIGITAL UTILITY METER
NEUTRAL CONNECTION TO GROUND
DIESEL ENGINE GENERATOR
KEY INTERLOCK
RELAY
CONTACTOR
PHOTOCELL
ELECTRICAL MOTOR
20 - MOTOR HORSEPOWER
Y
M
KWH
V
RECEPTACLES
RECESSED SIMPLEX
RECESSED DUPLEX
RECESSED QUAD
CEILING RECESSED DUPLEX
FLOORBOX RECESSED DUPLEX
FLOORBOX RECESSED QUAD
SPECIAL RECEPTACLE
(REFER TO DRAWINGS OR PANEL SCHEDULE FOR
NEMA CONFIGURATION)
JUNCTION BOXES
RECESSED IN WALL, UON
RECESSED IN FLOOR, UON
SURFACE MOUNTED, UON
SWITCHES
DISCONNECT SWITCH ("SP" MODIFIER = SINGLE
POINT / DISCONNECT PART OF EQUIPMENT)
MOTOR-RATED SWITCH
COMBINATION STARTER/DISCONNECT SWITCH
M
POWER DEVICES GENERAL INFORMATION
LP-X
GFI
ANY RECEPTACLE LISTED ABOVE
2'X4' FIXTURE, UON
EMERGENCY FIXTURE WITH BATTERY BACKUP, UON
(NOTE: ALL FIXTURES NOTED ON PLAN WITH HALF-
SHADE INDICATE EMERGENCY BATTERY BACKUP)
1'X4' FIXTURE, UON
2'X2' FIXTURE, UON
DOWNLIGHT OR SPOTLIGHT, UON
EXIT SIGNS, CEILING: ARROW INDICATES EGRESS
DIRECTION
EXIT SIGNS, WALL: ARROW INDICATES EGRESS
DIRECTION
PHOTOCELL
WALL MOUNTED FIXTURE
EMERGENCY WALL MOUNTED FIXTURE
FLASHING BLUE LIGHT FIXTURE, CEILING MOUNTED
FLASHING BLUE LIGHT FIXTURE, WALL MOUNTED AT
MIN. 10'-0" AFF, UON
FLASHING RED LIGHT FIXTURE, CEILING MOUNTED
FIXTURE TYPE
F1E
LP-1
10' - 0" a
'E' DENOTES EMERGENCY FIXTURE
SWITCH 'LEG'
• THE SWITCH WITH SAME LETTER
OPERATES THIS FIXTURE
3a , 3b
SWITCH 'LEG'
DESIGNATION
DEMARCATION
D: DIMMER
TM: TIMER
OC: OCCUPANCY SENSOR
3: 3-WAY
4: 4-WAY
EP: EXPLOSION PROOF
BL: FLASHING BLUE LIGHT
NOTES:
1. NO DEMARCATION OR SWITCH 'LEG'
INDICATES THAT THE SWITCH CONTROLS
ALL OF THE FIXTURES WITHIN THE SAME
ROOM
2. ADDITIONAL DEMARCATIONS SEPARATED
BY A COMMA "," INDICATE ADDITIONAL
SWITCHES WITHIN A COMMON OUTLET
BACKBOX.
LIGHTING FIXTURES
FIXTURE GENERAL INFORMATION
CONTROL DEVICES GENERAL INFORMATION
TOGGLE SWITCH
VFD
ST
VS
AS
A
• REFER TO FIXTURE SCHEDULE FOR FIXTURE
TYPE INFORMATION
SURFACE SIMPLEX
SURFACE DUPLEX
SURFACE QUAD
CLASSROOM
CTRL: OC
ROOM / SPACE TAG
LIGHTING CONTROLS REQUIRED FOR A
PARTICULAR SPACE. SEE SHEET EL103
FOR LIGHTING CONTROL ABBREVIATIONS
FOR EACH SPACE
EF-X
LP-X
GFI
J
EQUIPMENT IDENTIFICATION
ANY JUNCTION BOX LISTED ABOVE
SYMBOL MODIFIER(S)
SYMBOL MODIFIER(S)
PANELBOARD - CIRCUIT NUMBER
PANELBOARD - CIRCUIT
FIXTURE MOUNTING HEIGHT
(IF APPLICABLE)
• 120V, NEMA 5-20R, UON
LIGHTING CONTROL GENERAL INFORMATION
SYMBOLS - ONE-LINE DIAGRAM
DM
J
M
J
EF-X
HL-X
GFI
M
EQUIPMENT IDENTIFICATION
MECHANICAL EQUIPMENT CONNECTION
• SEE MECHANICAL EQUIPMENT
SCHEDULE FOR CONNECTION
INFORMATION
SYMBOL MODIFIER(S)
PANELBOARD - CIRCUIT
REMOTE DISCONNECT SWITCH:
• SEE MECHANICAL EQUIPMENT
SCHEDULE FOR ADDITIONAL
INFORMATION
EQUIPMENT CONNECTIONS
MECHANICAL EQUIPMENT CONNECTION. PROVIDE
DISCONNECT / STARTER / VFD AS INDICATED ON
MECHANICAL EQUIPMENT PLAN AND SCHEDULES
ELECTRICAL SINGLE POINT CONNECTION
RECEPTACLES WITH COMM OUTLETS
RECESSED FLOOR BOX W. QUAD 5-20R POWER,
COMPARTMENTED GANG FOR COMM AND AV
COMPARTMENT.
RECESSED FLOOR BOX W. QUAD 5-20R POWER,
COMPARTMENTED GANG FOR COMM.
RECESSED POWER/COMM FLOOR BOX PROVIDED
FOR FINAL CONNECTION TO SYSTEMS FURNITURE.
• SEE COMMUNICATIONS OUTLET DETAILS FOR
POWER AND COMMUNICATIONS REQUIREMENTS
N
G
G
WIRING RACEWAY TYPES
LADDER TYPE CABLE TRAY
EXPOSED CONDUIT - SINGLE LINE
CONCEALED CONDUIT - SINGLE LINE
UNDERGROUND DUCTBANK
CONDUIT ROUTED VERTICALLY
K
PC
SYMBOLS - GROUNDING / LIGHTNING
PROTECTION
AIR TERMINAL
GROUND ROD
GROUND TEST WELL
STATIC GROUND
GROUNDING COUNTERPOISE/CONDUCTOR
• BURIED, BARE CABLE (EXTERIOR)
• COPPER, #4/0 AWG MINIMUM, UON
GROUND BAR
MGB = MAIN GROUND BUSBAR
PBB, SBB = TELECOMM BONDING BUSBARS
MPG = LAB MULTIPOINT GROUND (AND STATIC)
BOLTED GROUND CONNECTION
EXOTHERMIC WELDED CONNECTION
DOWN CONDUCTOR
SYMBOL MODIFIERS
AC
C
CB
CO
DW
EP OR EXP
F
GD
GFI
IG
MW
PR
PROJ
REF
SB
SH
SP
SW: XX
TV
VM
WC
WF
WP
WPIU
XX" AFF
XX" AFP
ABOVE COUNTER MOUNTING
RECESSED IN CEILING
COFFEE BREWER
COPIER
DISHWASHER
EXPLOSION PROOF
RECESSED IN FLOOR
GARBAGE DISPOSAL
GROUND FAULT CIRCUIT INTERRUPTER
ISOLATED GROUND
MICROWAVE
PRINTER
PROJECTOR
REFRIGERATOR
SMART BOARD
SHREDDER
SINGLE POINT CONNECTION
CONTROLLED BY SWITCH LABELED "XX"
TELEVISION OR DISPLAY MONITOR
VENDING MACHINE
WALL-MOUNTED CLOCK
WATER COOLER
WEATHERPROOF, WITH GFI
WEATHERPROOF IN USE, WITH GFI
MOUNT XX" AFF
MOUNT XX" AFP
SYMBOLS - POWER
EQUIPMENT
LP11
• ELECTRICAL EQUIPMENT INCLUDING, BUT NOT
LIMITED TO, TRANSFORMERS, SWITCHBOARDS AND
PANELBOARDS ARE DRAWN TO SCALE IN THE
PLANS AND ARE CALLED OUT WITH A UNIQUE
IDENTIFIER.
EQUIPMENT IDENTIFIER
• COORDINATE JUNCTION BOX INSTALLATION
WITH NEARBY EQUIPMENT.
R
C
SEE NOTE 2
SYMBOLS - SITE
FBAV#
SF#
SPD
E
J
SYMBOLS - DEMOUNTABLE PARTITION
AND WORKSTATIONS
SF#
POWER/COMMUNICATION JUNCTION BOX
CONNECTION. REFER TO DETAIL B1 ON
SHEET EP502 AND A1 ON SHEET EP503.
MFM
NUMBER OF WORKSTATION ON CIRCUIT
BL
BL
FB#
LEGEND NOTES
SYMBOL ORIENTATION DOES NOT IMPLY DEVICE OR
EQUIPMENT ORIENTATION UNLESS NOTED AS SUCH.
SYMBOL SIZE DOES NOT IMPLY EQUIPMENT SIZE, UON.
MOUNTING HEIGHT INDICATED IN LEGEND AND ON THE
DRAWINGS SHALL BE THE DISTANCE MEASURED FROM
THE CENTER OF THE DEVICE TO THE FINISHED FLOOR.
NOT ALL SYMBOLS ON THIS SHEET ARE USED AS PART
OF THIS PROJECT.
1.
2.
3.
4.
UNDERGROUND ELECTRICAL
EXISTING ELECTRICAL DUCTBANK
MANHOLE
HANDHOLE
TRANSFORMER
POLE MOUNTED LIGHT FIXTURE
BOLLARD LIGHT FIXTURE, UON
MH
UE
HH
E
SINGLE POINT CONNECTION
SP
RL
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
P
L O
T D
A T
E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C
O N
T R
A C
T N
O
A F
D R
A W
IN
G
C O
D E
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
SHEET ID
P R
O J E
C T
N O
K
R S
M
S C
O T
T A
IR
F
O R
C E
B A
S E
IL
L
IN
O
IS
J O
IN
T
O P
E R
A T
IO
N
S
M
IS
S
IO
N P
L A
N N
IN
G
C E
N T
M
P C
A S
S H
O W
N
C E
R T
IF
IE
D F
IN
A
L
IS
S
U E
D F
O R
B
ID
1 753 92 864 10
A
B
C
D
E
F
G
/1
/2
V D
Y D
E-001
D R
ID
L E
Y
P O
'G O
R M
A N
Z M
A T
H E
W S
M A
R C
H
E
-0 .D
W G
E L E
C T
R
IC
A L L
E G
E N
D
O F
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
C
E R
T
IF
IE
D
F
IN
A L
I S
S U
E D
F O
R B
ID
D
E C
11 DEC 2020
CONTROLLED UNCLASSIFIED INFORMATION
CONTROLLED UNCLASSIFIED INFORMATION
ARIMS: 200A Disposition: Maintain for 15 yrs after construction
W
2Q R
R
_P la ns _V ol _I
V-
EXIT
NOTE 4
NOTE 1
NOTE 2
SINK OR
BASIN
CEILING
FINISHED
FLOOR
1.
2.
3.
4.
5.
6.
7.
COORDINATE ABOVE COUNTER DEVICES AND RECEPTACLES WITH
CASEWORK OR COUNTERS SUCH THAT THE DEVICES AND
RECEPTACLES ARE LOCATED AT +42" AFF OR 6" ABOVE THE
COUNTERTOP OR BACKSPLASH, WHICHEVER IS HIGHER.
ALL RECEPTACLES INSTALLED WITHIN 6'-0" OF ANY SINK OF BASIN
SHALL HAVE GFI PROTECTION. DO NOT INSTALL RECEPTACLES
WITHIN 12" OF THE EDGE OF A SINK OR BASIN.
COORDINATE WITH THE COMMUNICATIONS DRAWINGS TO ENSURE
THAT A DUPLEX RECEPTACLE IS INSTALLED WITHIN 18" HORIZONTAL
TO ALL SIGNAL AND DATA DEVICE LOCATIONS, UON.
SWITCHES AND OTHER FLUSH WALL-MOUNTED DEVICES SHALL BE
MOUNTED WITHIN 16" OF DOORFRAME. COORDINATE WITH
ARCHITECTURAL DRAWINGS FOR DOORS WITH ADJACENT
SIDELIGHTS. WHERE DEVICES ARE SHOWN ADJACENT TO THE DOOR
ON THE HINGE-SIDE OF THE DOOR, AND THE DOOR SWINGS IN A
MANNER THAT SHALL BLOCK THE DEVICE, MOUNT THE DEVICE 12"
BEYOND THE DOOR SWING. COORDINATE ROUGH-IN LOCATIONS
WITH DIV. 27 AND 28 DEVICES AS WELL. COORDINATE MOUNTING
LOCATION WITH OTHER TRADES TO ENSURE A UNIFORM MOUNTING
AND AESTHETICALLY-PLEASING APPEARANCE.
MOUNTING HEIGHT INDICATED IN LEGEND AND ON THE DRAWINGS
SHALL BE THE DISTANCE MEASURED FROM THE CENTER OF THE
DEVICE TO THE FINISHED FLOOR, UON.
COORDINATE FINAL RECEPTACLE HEIGHT AND LOCATION FOR ALL
DEVICE RECEPTACLES WITH ARCHITECTURAL/INTERIORS AND AV
PLANS.
COORDINATE INSTALLATION OF DEVICES IN DEMOUNTABLE
PARTITIONS WITH DEMOUNTABLE PARTITION CONTRACTOR AND
DETAIL A1, SHEET EP503.
NOTE 3
S
TYPICAL DEVICE MOUNTING DETAIL AND NOTES
NOTE 5
ALL CONDUCTORS SHALL BE RUN IN CONDUIT, AND ALL CONDUIT
SHALL BE ROUTED CONCEALED UNLESS OTHERWISE NOTED ON THE
DRAWINGS.
ALL NEW EQUIPMENT SHALL BE FIELD MARKED TO WARN QUALIFIED
PERSONS OF POTENTIAL ELECTRIC ARC FLASH HAZARD IN
ACCORDANCE WITH NFPA 70 AND 70E.
COORDINATE WITH MECHANICAL TRADE REGARDING ELECTRICAL
REQUIREMENTS OF ACTUAL EQUIPMENT PROVIDED.
MOUNTING HEIGHT FOR LIGHT FIXTURES SHALL BE FROM THE BOTTOM
OF FIXTURES TO THE FINISHED FLOOR OR GRADE.
ALL ELECTRICAL WORK SHALL COMPLY WITH NEC (NFPA 70), NFPA 72,
NFPA 101, AND DoD UNIFORM FACILITY CRITERIA, OR AIR FORCE
TECHNICAL LETTERS, IN ADDITION TO LOCAL CODES AND
ORDINANCES.
ALL GROUNDING SHALL COMPLY WITH NFPA 70, ARTICLE 250 FOR
ELECTRICAL SYSTEMS AND NEC ARTICLE 800 AND TIA-607-D FOR
TELECOMMUNICATIONS SYSTEMS.
PROVIDE A GREEN CONTINUOUS INSULATED EQUIPMENT GROUNDING
CONDUCTOR TO ALL ELECTRICAL, TELECOMMUNICATIONS AND
SECURITY EQUIPMENT SIZED PER NEC ARTICLE 250 AND TIA 607.
ALL CONDUCTORS SHALL BE COPPER.
ALL ELECTRICAL EQUIPMENT AND OUTLET INSTALLATION LOCATIONS
SHALL BE COORDINATED WITH FURNITURE INSTALLATION.
COORDINATE PENETRATIONS IN FIRE RATED WALLS WITH DETAILS
SHOWN ON ARCHITECTURAL DRAWINGS.
ALL NEW FLOOR MOUNTED ELECTRICAL EQUIPMENT INCLUDING BUT
NOT LIMITED TO SWITCHBOARDS, TRANSFORMERS, MOTOR CONTROL
CENTERS, AND POWER CONDITIONERS SHALL BE MOUNTED ON A
CONCRETE EQUIPMENT PAD IN ACCORDANCE WITH STRUCTURAL
DETAILS
AIC RATING LISTED ON ELECTRICAL EQUIPMENT IS A MINIMUM RATING.
UNLESS OTHERWISE NOTED, ALL CIRCUIT BREAKERS RATED AT 400A
AND LARGER SHALL BE 100 PERCENT RATED ASSEMBLIES.
PER UFC 3-560-01, NORMAL MAINTENANCE IS NOT AUTHORIZED TO BE
PERFORMED 'HOT' ON DISCONNECTS, STARTERS AND VFDS.
REASONABLE ACCESS HAS BEEN TAKEN INTO ACCOUNT.
ALL AREAS DISTURBED BY TRENCHING / DIGGING FOR DUCT AND
MAINTENANCE HOLE INSTALLATION SHALL BE RETURNED TO THE
ORIGINAL CONDITION PRIOR TO BEGINNING OF PROJECT.
COORDINATE ALL PRIMARY POWER WORK WITH BASE CIVIL
ENGINEERING AND COR. POC FOR BASE CIVIL ENGINEERING IS ERIC
DIEHL 618-256-4890
TYPICAL DEVICE MOUNTING HEIGHTS (UON):
REF
ICE
CO
GD
FPD
TV
SB
TZC
WF
COF
MIC
AC
CRD
REFRIGERATOR, 48" AFF
ICE MACHINE, 48" AFF
COPIER OR PLOTTER, 18" AFF
GARBAGE DISPOSAL, 18" AFF (NOTE 6)
FLAT PANEL DISPLAY (NOTE 6)
TELEVISION (NOTE 6)
SMART BOARD (NOTE 6)
TIME ZONE CLOCK (NOTE 6)
WATER COOLER (NOTE 6)
COFFEE MAKER (NOTE 1, NOTE 6)
MICROWAVE (NOTE 1, NOTE 6)
ABOVE COUNTER, SEE "DEVICE MOUNTING NOTES", (NOTE 1)
CREDENZA, 18" AFF
J
GENERAL NOTES:
APPLICABLE TO ALL ELECTRICAL SHEETS
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
ABBREVIATIONS ARC FLASH LABEL FOR EQUIPMENT
A AMPERES
AC ALTERNATING CURRENT
AFF ABOVE FINISHED FLOOR
AIC AMPERES INTERRUPTING CAPACITY
AV AUDIO/VIDEO
AWG AMERICAN WIRE GAUGE
BAS BUILDING AUTOMATION SYSTEM
BBC BONDING BACKBONE CONDUCTOR
BICSI BUILDING INDUSTRY CONSULTING SERVICE
INTERNATIONAL
C CONDUIT
CAT CATEGORY
CATV CABLE TELEVISION
CBP COPPER BACKBONE PATCH PANEL
CCTV CLOSED CIRCUIT TELEVISION
CH CHILLED WATER
CL CENTERLINE
COMM COMMUNICATIONS
COR CONTRACTING OFFICER REPRESENTATIVE
CPP COPPER HORIZONTAL PATCH PANEL
CT CABLE TRAY
CU COPPER
DBL. N. DOUBLE NEUTRAL
EC EMPTY CONDUIT
EF EXHAUST FAN
EGC EQUIPMENT GROUNDING CONDUCTOR
EIA ELECTRONICS INDUSTRIES ASSOCIATIONS
EM/NL EMERGENCY / NIGHT LIGHT
EMT ELECTRICAL METALLIC TUBING
EPO EMERGENCY POWER OFF
ETR EXISTING TO REMAIN
EX OR EXP EXPLOSION PROOF
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FBO FURNISHED BY OTHERS
FO FIBER OPTIC
FPD FLAT PANEL DISPLAY
FPP FIBER OPTIC PATCH PANEL
FT FEET OR FOOT
GFCI GOVERNMENT FURNISHED, CONTRACTOR
INSTALLED
GFGI GOVERNMENT FURNISHED AND INSTALLED
GFI GROUND FAULT INTERRUPTER
G OR GND GROUND
GFE GOVERNMENT FURNISHED EQUIPMENT
GFR GROUND FAULT RELAY
GFP GROUND FAULT PROTECTION
GRS GALVANIZED RIGID STEEL CONDUIT
HID HIGH INTENSITY DISCHARGE
HZ HERTZ
IDS INTRUSION DETECTION SYSTEM
IG ISOLATED GROUND
IPDS INTERGRATED POWER DISTRIBUTION SYSTEM
K KILO
KCMIL THOUSAND CIRCULAR MILS
KVA KILOVOLT AMPERES
KWH KILOWATT HOURS
LC LIGHTING CONTACTOR
LP LIGHTNING PROTECTION
LPS LIGHTNING PROTECTION SYSTEM
LSI LONG TIME, SHORT TIME, INSTANTANEOUS
LW LOCKABLE WIREWAY
MAX MAXIMUM
MCB MAIN CIRCUIT BREAKER
MDP MAIN DISTRIBUTION PANEL
MH MAINTENANCE HOLE
MLO MAIN LUGS ONLY
MM MULTIMODE
MN/PA MASS NOTIFICATION/PUBLIC ADDRESS
MTD MOUNTED
N NEUTRAL CONDUCTOR
N.C. NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL MANUFACTURER'S
ASSOCIATION
NIC NOT IN CONTRACT
NIPR NON-CLASSIFIED INTERNET PROTOCOL ROUTING
NL NIGHT LIGHT
N.O. NORMALLY OPEN
NTS NOT TO SCALE
OC ON CENTER
PBB PRIMARY BONDING BUSBAR
PDU POWER DISTRIBUTION UNIT
PIV POST INDICATOR VALVE
PR PAIR
PVC POLYVINYL CHLORIDE
RBB RACK BONDING BUSBAR
RECEPT RECEPTACLE
RGS RIGID GALVANIZED STEEL CONDUIT
RM ROOM
RMC RIGID METAL CONDUIT
SBB SECONDARY BONDING BUSBAR
SBC SECONDARY BONDING CONDUCTOR
SCCR SHORT CIRCUIT CURRENT RATING
STP SHIELDED TWISTED PAIR
SIPR SECRET INTERNET PROTOCOL ROUTING
SM SINGLE MODE
SPD SURGE PROTECTION DEVICE
SPECS CONTRACT SPECIFICATIONS
SPDT SINGLE POLE DOUBLE THROW
SPST SINGLE POLE SINGLE THROW
SRG STATIC REFERENCE GRID
STR STRAND
T TRANSFORMER
TB TELEPHONE BACKBOARD
TBB TELECOMMUNICATIONS BONDING BACKBONE
TDMM TELECOMMUNICATIONS DISTRIBUTION METHODS
MANUAL
TEBC TELECOMMUNICATIONS EQUIPMENT BONDING
CONDUCTOR
TECH TECHNICIAN
TR TELECOMMUNICATIONS ROOM
TVSS TRANSIENT VOLTAGE SURGE SUPPRESSION
TYP TYPICAL
TZC TIME ZONE CLOCK
UL UNDERWRITERS' LABORATORIES
UON UNLESS OTHERWISE NOTED
UTP UNSHIELDED TWISTED PAIR
V VOLTS
VA VOLT AMPERES
VFD VARIABLE FREQUENCY DRIVE
W WIRE OR WATT
WP WEATHERPROOF
WPIU WEATHERPROOF WHILE IN USE
XFMR TRANSFORMER
Z IMPEDANCE
1. PROVIDE SELF-ADHESIVE VINYL LABEL TO AFFIX TO ELECTRICAL EQUIPMENT TO
WARN OF ARC FLASH HAZARDS.
2. THE LABEL FORMAT AND TEXT SHALL BE IN ACCORDANCE WITH THE FIGURE BELOW.
3. THE LABEL SHALL BE LOCATED ON THE EQUIPMENT TO BE CLEARLY VISIBLE
TO QUALIFIED PERSONS BEFORE EXAMINATION, ADJUSTMENT, SERVICING, OR
MAINTENANCE OF THE EQUIPMENT.
4. THE SIZE OF THE LABEL SHALL BE:
EQUIPMENT TYPEHEIGHT WIDTH
INDOOR 50mm 75mm OUTDOOR 100mm 150mm
5. A DOWNLOADABLE WINDOWS METAFILE IS AVAILABLE ON THE WHOLE BUILDING
DESIGN GUIDE WEBSITE (WWW.WDBG.ORG) FOR USE IN A LABEL MAKING MACHINE.
A. THE FILE IS LOCATED ON THE "NAVFAC CADD DETAILS" PAGE. TO NAVIGATE
TO THIS LOCATION, FOLLOW: HOME > DOCUMENTS & REFERENCES > CCB >
CADD LIBRARY > NAVFAC CADD RESOURCES > NAVFAC CADD DETAILS.
6. PROVIDE ARC FLASH WARNING LABELS ON ELECTRICAL EQUIPMENT LIKELY TO REQUIRE
EXAMINATION, SERVICING, OR MAINTENANCE WHILE ENERGIZED. EQUIPMENT SHALL
INCLUDE BUT NOT LIMITED TO INCLUDE PAD-MOUNTED TRANSFORMERS, SWITCHGEAR,
SWITCHBOARDS, PANELBOARDS, DISCONNECT SWITCHES, INDUSTRIAL CONTROL
PANELS, AND METER SOCKET ENCLOSURES.
7. PROVIDE A COPY OF THE ARC FLASH STUDY REQUIRED BY SECTION 26 28 01.00 10 POSTED IN THE
ELECTRICAL ROOM.
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
P
L O
T D
A T
E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C
O N
T R
A C
T N
O
A F
D R
A W
IN
G
C O
D E
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
SHEET ID
P R
O J E
C T
N O
K
R S
M
S C
O T
T A
IR
F
O R
C E
B A
S E
IL
L
IN
O
IS
J O
IN
T
O P
E R
A T
IO
N
S
M
IS
S
IO
N P
L A
N N
IN
G
C E
N T
M
P C
A S
S H
O W
N
C E
R T
IF
IE
D F
IN
A
L
IS
S
U E
D F
O R
B
ID
1 753 92 864 10
A
B
C
D
E
F
G
/1
/2
V D
Y D
E-002
D R
ID
L E
Y
P O
'G O
R M
A N
Z M
A T
H E
W S
M A
R C
H
E
-0 .D
W G
E L
E C
T R
IC
A
L L
E G
E N
D
O F
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
C
E R
T
IF
IE
D
F
IN
A L
I S
S U
E D
F O
R B
ID
D
E C
11 DEC 2020
CONTROLLED UNCLASSIFIED INFORMATION
CONTROLLED UNCLASSIFIED INFORMATION
ARIMS: 200A Disposition: Maintain for 15 yrs after construction
W
2Q R
R
_P la ns _V ol _I
V-
C B
C B
E
E
E
EEE
C O
M M
C O
M M
G
G
G
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
CP#1
STORM MANHOLE
RIM ELEV.: 447.12'
F.L. IN(W):445.62'
F.L. IN(S): 445.63'
F.L. OUT(N):445.71'
STORM MANHOLE
RIM ELEV.: 447.16'
F.L. OUT(E): 445.76'
STORM MANHOLE
RIM ELEV.: 447.41'
F.L. OUT (N): 445.91'
F.L. IN (W): 445.86'
STORM MANHOLE
RIM ELEV.: 447.52'
F.L. OUT(E): 445.92'
SANITARY MANHOLE
RIM ELEV.: 445.91'
F.L. IN(W): 438.36'
FL. OUT(S): 438.21'
SANITARY MANHOLE
RIM ELEV.: 443.80'
F.L. IN (N): 437.81'
F.L. OUT (S): 437.79'
"SILTED"
C B
SAN SAN
SAN
SAN
SAN
C B
C B
C B
CP#3
CP#2
CP#4
CP#5
CP#6
C O
M
M
C O
M M
LP
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH MH
MH
MH
MH
MH
Y4
L1-13
Y4
L1-13
D E
S I G
N E
D
B
Y
M A
R K
D E
S C
R I P
T I O
N D
A T
E
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
F I
N
A M
E
S I Z
E
P L O
T
S
C A
L E
P
L O
T
D
A T
E
I S
S U
E
D
A T
E
P R
O J E
T
C O
N T
R A
F
A
W I N
G
C
O D
E
X
S O
L I C
I T
A T
I O
N
N
O
U S
A
R M
Y
C
O R
P
E
N G
I N
E E
R S
L O
U I S
V I L
I S
T R
I C
T
L O
U I S
V I L L E
K
E N
T U
C K
Y
W
A R
D
P
A R
K W
A Y
K
A N
S A
S
C
I T
Y
M
O
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
SHEET ID
P R
O J E
K
R S
M
S C
O T
T
A
R
S
E
I L L I N
O I S
J O
I N
T
O
P E
R A
T I O
M
S
S I O
N
P
L A
N N
I N
G
C
E N
T E
R
J O
M P
C
H O
W N
C E
R T
I F
I E
D
F
I N
S
S U
D
1 753 92 864 10
A
B
C
D
E
F
G
C
E R
T I F
I E
D
F
I N
A L
I S
S U
D
D E
C
V D
Y D
ES100
M
H
A R
A L S
O N
P
O
G
O R
M A
N
Z
M
A T
H E
W
E
S
D
W G
O V
E R
A L L
E
L E
C T
R I C
A L
S
I T
E
P
L A
N
N
KEY PLAN
NOT TO SCALE
C O
C O
C O
C O
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
F H
F H
F H
F H
F H
F H
F H
E
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
M
A
P
L
E
10 14
A1
OVERALL ELECTRICAL SITE PLAN
SCALE: 1" = 150'-0"
N
100' 200'0
ES103/ES103A
ES105
ES102/ES102A
ES104
ES107
ES106 ES110
ES108
ES114
ES109
11 DEC 2020
CONTROLLED UNCLASSIFIED INFORMATION
CONTROLLED UNCLASSIFIED INFORMATION
ARIMS: 200A Disposition: Maintain for 15 yrs after construction
W
2Q R
R
_P la ns _V ol _I
V-
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
G
G
G
G
G
G
G
E
E
S A
N S
A N
S A
N S
A N
S A
N S
A N
S A
N S
A N
S A
N
S
A
N
E M
E
LP
U
E
UE
U
E
U E
UE UE UE UE UE UE UE
U
E
U
E
U E
U E
U E
U E
UE UE UE UE UE UE
D E
S I G
N E
D
B
Y
M A
R K
D E
S C
R I P
T I O
N D
A T
E
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
F I
M
E
S I Z
E
P L O
T
S
C A
L E
P
L O
T
D
A T
E
I S
S U
E
D
A T
E
P R
O J E
C O
N T
R A
A
W I N
G
C
O D
E
X
S O
L I C
I T
A T
I O
N
N
O
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
L O
U I S
V I L
S
T R
I C
T
L O
U I S
V I L L E
K
E N
T U
C K
Y
W
A R
D
P
A R
K W
A Y
K
A N
S A
S
C
I T
Y
M
O
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
SHEET ID
P R
O J E
K
R S
M
S C
O T
T
A
R
S
E
I L L I N
O I S
J O
I N
T
O
P E
R A
T I O
S
S I O
N
P
L A
N N
I N
G
C
E N
T E
R
J O
M P
C
O
W N
C E
R T
I F
I E
D
F
I N
S
S U
D
1 753 92 864 10
A
B
C
D
E
F
G
C
E R
T I F
I E
D
F
I N
A L
I S
S U
D
D E
C
V D
Y D
ES102
M
H
A R
A L S
O N
P
O
G
O R
M A
N
Z
M
A T
H E
E
S
D
W G
E L E
C T
R I C
A L
S
I T
E
P
L A
N
N
KEY PLAN
NOT TO SCALE
C O
C O
C O
C O
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
F H
F H
F H
F H
F H
F H
F H
E
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
M
A
P
L
E
10 14
A1
ELECTRICAL SITE PLAN 2
SCALE: 1" = 20'-0"
N
20' 40'0
M A
T C
H L I N
E
S
E
N
T I N
U A
T I O
N
MATCHLINE SEE SHEET ES103 FOR CONTINUATION
NOTES:
1. ROUTING SHOWN IS DIAGRAMMATIC. CONTRACTOR
SHALL ROUTE CONDUITS TO AVOID BUILDING
STRUCTURES AND ALL UTILITIES BELOW AND/OR ABOVE
GRADE. CONTRACTOR SHALL COORDINATE FINAL
LOCATION OF ALL ELECTRICAL AND
TELECOMMUNICATIONS EQUIPMENT WITH OTHER
DISCIPLINES.
2. FOR GENERAL NOTES, LEGEND, AND ABBREVIATIONS
SEE DRAWINGS E-001 AND E-002.
3. SEE LIGHT FIXTURE SCHEDULE ON SHEET EL601.
4. SEE ELECTRICAL ONE-LINE DIAGRAMS ON EP600 SERIES
SHEETS.
5. SEE ELECTRICAL SITE DETAILS ON ES500 SERIES
SHEETS.
6. SEE ELECTRICAL PANELBOARD SCHEDULES ON EP700
SERIES SHEETS.
7. SEE EXTERIOR LIGHTING CONTACTOR SCHEMATICS ON
SHEET EL502.
KEYED NOTES:
JOMPC BUILDING
B U
C H
E R
SEE DETAIL A4 ON SHEET ES503 FOR LIGHT POLE BASE
DETAIL.
SEE DETAIL E7 ON SHEET ES503 FOR TYPICAL BOLLARD
INSTALLATION DETAIL.
LIGHT FIXTURE TYPE Y3
L1-13 (TYP OF 16)
LIGHT FIXTURE TYPE P2
L1-13
LIGHT FIXTURE TYPE P2
L1-13
TO PANEL L1
IN ELECTRICAL
ROOM 1021
(TYP)
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
11 DEC 2020
CONTROLLED UNCLASSIFIED INFORMATION
CONTROLLED UNCLASSIFIED INFORMATION
ARIMS: 200A Disposition: Maintain for 15 yrs after construction
W
2Q R
R
_P la ns _V ol _I
V-
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
G
G
G
G
G
G
G
E
E
S A
N S
A N
S A
N S
A N
S A
N S
A N
S A
N S
A N
S A
N
S
A
N
E M
E
LP
U
E
UE
U
E
U E
UE UE UE UE UE UE UE
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
UE
UE
UE
UE
UE
UE UE UE UE UE UE UE UE UE UE UE UE
U
E
U
E
U E
U E
U E
U E
UE UE UE UE UE UE
UE UE UE
D E
S I G
N E
D
B
Y
M A
R K
D E
S C
R I P
T I O
N D
A T
E
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
F I
M
E
S I Z
E
P L O
T
S
C A
L E
P
L O
T
D
A T
E
I S
S U
E
D
A T
E
P R
O J E
C O
N T
R A
A
W I N
G
C
O D
E
X
S O
L I C
I T
A T
I O
N
N
O
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
L O
U I S
V I L
S
T R
I C
T
L O
U I S
V I L L E
K
E N
T U
C K
Y
W
A R
D
P
A R
K W
A Y
K
A N
S A
S
C
I T
Y
M
O
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
SHEET ID
P R
O J E
K
R S
M
S C
O T
T
A
R
S
E
I L L I N
O I S
J O
I N
T
O
P E
R A
T I O
S
S I O
N
P
L A
N N
I N
G
C
E N
T E
R
J O
M P
C
O
W N
C E
R T
I F
I E
D
F
I N
S
S U
D
1 753 92 864 10
A
B
C
D
E
F
G
C
E R
T I F
I E
D
F
I N
A L
I S
S U
D
D E
C
V D
Y D
ES102A
M
H
A R
A L S
O N
P
O
G
O R
M A
N
Z
M
A T
H E
E
S A
D
W G
E L E
C T
R I C
A L
S
I T
E
P
L A
N
O
P T
I O
N
N
KEY PLAN
NOT TO SCALE
C O
C O
C O
C O
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
F H
F H
F H
F H
F H
F H
F H
E
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
M
A
P
L
E
10 14
A1
ELECTRICAL SITE PLAN 2 - OPTION
SCALE: 1" = 20'-0"
N
20' 40'0
M A
T C
H L I N
E
S
E
N
T I N
U A
T I O
N
MATCHLINE SEE SHEET ES103A FOR CONTINUATION
NOTES:
1. ROUTING SHOWN IS DIAGRAMMATIC. CONTRACTOR
SHALL ROUTE CONDUITS TO AVOID BUILDING
STRUCTURES AND ALL UTILITIES BELOW AND/OR ABOVE
GRADE. CONTRACTOR SHALL COORDINATE FINAL
LOCATION OF ALL ELECTRICAL AND
TELECOMMUNICATIONS EQUIPMENT WITH OTHER
DISCIPLINES.
2. FOR GENERAL NOTES, LEGEND, AND ABBREVIATIONS
SEE DRAWINGS E-001 AND E-002.
3. SEE LIGHT FIXTURE SCHEDULE ON SHEET EL601.
4. SEE ELECTRICAL ONE-LINE DIAGRAMS ON EP600 SERIES
SHEETS.
5. SEE ELECTRICAL SITE DETAILS ON ES500 SERIES
SHEETS.
6. SEE ELECTRICAL PANELBOARD SCHEDULES ON EP700
SERIES SHEETS.
7. SEE EXTERIOR LIGHTING CONTACTOR SCHEMATICS ON
SHEET EL502.
KEYED NOTES:
JOMPC BUILDING
B U
C H
E R
SEE DETAIL A4 ON SHEET ES503 FOR LIGHT POLE BASE
DETAIL.
CUT AND PATCH ROADWAY PER CIVIL SPECIFICATIONS
TO MATCH EXISTING.
SEE DETAIL E7 ON SHEET ES503 FOR TYPICAL BOLLARD
INSTALLATION DETAIL.
LIGHT FIXTURE TYPE P2
L3-11
LIGHT FIXTURE TYPE Y3
L1-13 (TYP OF 16)
LIGHT FIXTURE TYPE P1
L3-11
LIGHT FIXTURE
TYPE P1
L3-11
LIGHT FIXTURE
TYPE P1
L3-11
(TYP)
LIGHT FIXTURE
TYPE P1
L3-11
LIGHT FIXTURE TYPE P2
L1-13
LIGHT FIXTURE TYPE P2
L1-13
TO PANEL L1
IN ELECTRICAL
ROOM 1021
TO PANEL L3
IN ELECTRICAL
ROOM 1105
HH
HH
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
11 DEC 2020
CONTROLLED UNCLASSIFIED INFORMATION
CONTROLLED UNCLASSIFIED INFORMATION
ARIMS: 200A Disposition: Maintain for 15 yrs after construction
W
2Q R
R
_P la ns _V ol _I
V-
M M
C O
M M
C
O
M
M
C
O
M
M
C
O
M
M
E
F H
F H
E M
E M
CP#3
C O
M
M
C O
M
M
C O
M
M
C O
M
M
C O
M
M
C O
M
M
C O
M
M
C O
M
M
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
D E
S I G
N E
D
B
Y
M A
R K
D E
S C
R I P
T I O
N D
A T
E
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
F I
M
E
S I Z
E
P L O
T
S
C A
L E
P
L O
T
D
A T
E
I S
S U
E
D
A T
E
P R
O J E
C O
N T
R A
A
W I N
G
C
O D
E
X
S O
L I C
I T
A T
I O
N
N
O
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
L O
U I S
V I L
S
T R
I C
T
L O
U I S
V I L L E
K
E N
T U
C K
Y
W
A R
D
P
A R
K W
A Y
K
A N
S A
S
C
I T
Y
M
O
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
SHEET ID
P R
O J E
K
R S
M
S C
O T
T
A
R
S
E
I L L I N
O I S
J O
I N
T
O
P E
R A
T I O
S
S I O
N
P
L A
N N
I N
G
C
E N
T E
R
J O
M P
C
O
W N
C E
R T
I F
I E
D
F
I N
S
S U
D
1 753 92 864 10
A
B
C
D
E
F
G
C
E R
T I F
I E
D
F
I N
A L
I S
S U
D
D E
C
V D
Y D
ES103
M
H
A R
A L S
O N
P
O
G
O R
M A
N
Z
M
A T
H E
E
S
D
W G
E L E
C T
R I C
A L
S
I T
E
P
L A
N
A1
ELECTRICAL SITE PLAN 3
SCALE: 1" = 20'-0"
N
20' 40'0
N
KEY PLAN
NOT TO SCALE
C O
C O
C O
C O
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
F H
F H
F H
F H
F H
F H
F H
E
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
M
A
P
L
E
10 14
M A
T C
H L I N
E
S
E
N
T I N
U A
T I O
N
MATCHLINE SEE SHEET ES102 FOR CONTINUATION
MATCHLINE SEE SHEET ES104 FOR CONTINUATION
LIGHT FIXTURE TYPE P1
L1-13
LIGHT FIXTURE
TYPE P1
L1-13
LIGHT FIXTURE TYPE P1
L1-13
LIGHT FIXTURE TYPE P2
L1-13
LIGHT FIXTURE TYPE P2
L1-13
LIGHT FIXTURE TYPE P2
L1-13
NOTES:
1. ROUTING SHOWN IS DIAGRAMMATIC. CONTRACTOR
SHALL ROUTE CONDUITS TO AVOID BUILDING
STRUCTURES AND ALL UTILITIES BELOW AND/OR ABOVE
GRADE. CONTRACTOR SHALL COORDINATE FINAL
LOCATION OF ALL ELECTRICAL AND
TELECOMMUNICATIONS EQUIPMENT WITH OTHER
DISCIPLINES.
2. FOR GENERAL NOTES, LEGEND, AND ABBREVIATIONS
SEE DRAWINGS E-001 AND E-002.
3. SEE LIGHT FIXTURE SCHEDULE ON SHEET EL601.
4. SEE ELECTRICAL ONE-LINE DIAGRAMS ON EP600 SERIES
SHEETS.
5. SEE ELECTRICAL SITE DETAILS ON ES500 SERIES
SHEETS.
6. SEE ELECTRICAL PANELBOARD SCHEDULES ON EP700
SERIES SHEETS.
7. SEE EXTERIOR LIGHTING CONTACTOR SCHEMATICS ON
SHEET EL502.
KEYED NOTES:
SEE DETAIL A4 ON SHEET ES503 FOR LIGHT POLE BASE
DETAIL.
1(TYP)
11 DEC 2020
CONTROLLED UNCLASSIFIED INFORMATION
CONTROLLED UNCLASSIFIED INFORMATION
ARIMS: 200A Disposition: Maintain for 15 yrs after construction
W
2Q R
R
_P la ns _V ol _I
V-
M M
C O
M M
C
O
M
M
C
O
M
M
C
O
M
M
E
F H
F H
E M
E M
CP#3
C O
M
M
C O
M
M
C O
M
M
C O
M
M
C O
M
M
C O
M
M
C O
M
M
C O
M
M
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
D E
S I G
N E
D
B
Y
M A
R K
D E
S C
R I P
T I O
N D
A T
E
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
F I
M
E
S I Z
E
P L O
T
S
C A
L E
P
L O
T
D
A T
E
I S
S U
E
D
A T
E
P R
O J E
C O
N T
R A
A
W I N
G
C
O D
E
X
S O
L I C
I T
A T
I O
N
N
O
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
L O
U I S
V I L
S
T R
I C
T
L O
U I S
V I L L E
K
E N
T U
C K
Y
W
A R
D
P
A R
K W
A Y
K
A N
S A
S
C
I T
Y
M
O
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
SHEET ID
P R
O J E
K
R S
M
S C
O T
T
A
R
S
E
I L L I N
O I S
J O
I N
T
O
P E
R A
T I O
S
S I O
N
P
L A
N N
I N
G
C
E N
T E
R
J O
M P
C
O
W N
C E
R T
I F
I E
D
F
I N
S
S U
D
1 753 92 864 10
A
B
C
D
E
F
G
C
E R
T I F
I E
D
F
I N
A L
I S
S U
D
D E
C
V D
Y D
ES103A
M
H
A R
A L S
O N
P
O
G
O R
M A
N
Z
M
A T
H E
E
S A
D
W G
E L E
C T
R I C
A L
S
I T
E
P
L A
N
O
P T
I O
N
A1
ELECTRICAL SITE PLAN 3 - OPTION
SCALE: 1" = 20'-0"
N
20' 40'0
N
KEY PLAN
NOT TO SCALE
C O
C O
C O
C O
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
F H
F H
F H
F H
F H
F H
F H
E
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
M
A
P
L
E
10 14
M A
T C
H L I N
E
S
E
N
T I N
U A
T I O
N
MATCHLINE SEE SHEET ES102A FOR CONTINUATION
MATCHLINE SEE SHEET ES104 FOR CONTINUATION
LIGHT FIXTURE TYPE P2
L3-11
(TYP)
LIGHT FIXTURE TYPE P1
L1-13
LIGHT FIXTURE
TYPE P1
L1-13
LIGHT FIXTURE TYPE P1
L1-13
LIGHT FIXTURE TYPE P2
L1-13
LIGHT FIXTURE TYPE P2
L1-13
LIGHT FIXTURE TYPE P2
L1-13
NOTES:
1. ROUTING SHOWN IS DIAGRAMMATIC. CONTRACTOR
SHALL ROUTE CONDUITS TO AVOID BUILDING
STRUCTURES AND ALL UTILITIES BELOW AND/OR ABOVE
GRADE. CONTRACTOR SHALL COORDINATE FINAL
LOCATION OF ALL ELECTRICAL AND
TELECOMMUNICATIONS EQUIPMENT WITH OTHER
DISCIPLINES.
2. FOR GENERAL NOTES, LEGEND, AND ABBREVIATIONS
SEE DRAWINGS E-001 AND E-002.
3. SEE LIGHT FIXTURE SCHEDULE ON SHEET EL601.
4. SEE ELECTRICAL ONE-LINE DIAGRAMS ON EP600 SERIES
SHEETS.
5. SEE ELECTRICAL SITE DETAILS ON ES500 SERIES
SHEETS.
6. SEE ELECTRICAL PANELBOARD SCHEDULES ON EP700
SERIES SHEETS.
7. SEE EXTERIOR LIGHTING CONTACTOR SCHEMATICS ON
SHEET EL502.
KEYED NOTES:
SEE DETAIL A4 ON SHEET ES503 FOR LIGHT POLE BASE
DETAIL.
11 DEC 2020
CONTROLLED UNCLASSIFIED INFORMATION
CONTROLLED UNCLASSIFIED INFORMATION
ARIMS: 200A Disposition: Maintain for 15 yrs after construction
W
2Q R
R
_P la ns _V ol _I
V-
E
E
E
E
E
E
S D
S D
S D
C B
E
E
S T
S T
E M
E M
S D
S D
S D
S D
E M
CP#2
S
D
S
D
S
D
S
D
S
D
S
D
U E
U E
U E
U E
U E
U E
U E
U E
D E
S I G
N E
D
B
Y
M A
R K
D E
S C
R I P
T I O
N D
A T
E
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
F I
M
E
S I Z
E
P L O
T
S
C A
L E
P
L O
T
D
A T
E
I S
S U
E
D
A T
E
P R
O J E
C O
N T
R A
A
W I N
G
C
O D
E
X
S O
L I C
I T
A T
I O
N
N
O
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
L O
U I S
V I L
S
T R
I C
T
L O
U I S
V I L L E
K
E N
T U
C K
Y
W
A R
D
P
A R
K W
A Y
K
A N
S A
S
C
I T
Y
M
O
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
SHEET ID
P R
O J E
K
R S
M
S C
O T
T
A
R
S
E
I L L I N
O I S
J O
I N
T
O
P E
R A
T I O
S
S I O
N
P
L A
N N
I N
G
C
E N
T E
R
J O
M P
C
O
W N
C E
R T
I F
I E
D
F
I N
S
S U
D
1 753 92 864 10
A
B
C
D
E
F
G
C
E R
T I F
I E
D
F
I N
A L
I S
S U
D
D E
C
V D
Y D
ES104
M
H
A R
A L S
O N
P
O
G
O R
M A
N
Z
M
A T
H E
E
S
D
W G
E L E
C T
R I C
A L
S
I T
E
P
L A
N
N
KEY PLAN
NOT TO SCALE
C O
C O
C O
C O
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
F H
F H
F H
F H
F H
F H
F H
E
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
M
A
P
L
E
10 14
A1
ELECTRICAL SITE PLAN 4
SCALE: 1" = 20'-0"
N
20' 40'0
M A
T C
H L I N
E
S
E
F
N
T I N
U A
T I O
N
MATCHLINE SEE SHEET ES103 FOR CONTINUATION
LIGHT FIXTURE TYPE P3
L1-13
(TYP)
LIGHT FIXTURE TYPE P2
L1-13
NOTES:
1. ROUTING SHOWN IS DIAGRAMMATIC. CONTRACTOR
SHALL ROUTE CONDUITS TO AVOID BUILDING
STRUCTURES AND ALL UTILITIES BELOW AND/OR ABOVE
GRADE. CONTRACTOR SHALL COORDINATE FINAL
LOCATION OF ALL ELECTRICAL AND
TELECOMMUNICATIONS EQUIPMENT WITH OTHER
DISCIPLINES.
2. FOR GENERAL NOTES, LEGEND, AND ABBREVIATIONS
SEE DRAWINGS E-001 AND E-002.
3. SEE LIGHT FIXTURE SCHEDULE ON SHEET EL601.
4. SEE ELECTRICAL ONE-LINE DIAGRAMS ON EP600 SERIES
SHEETS.
5. SEE ELECTRICAL SITE DETAILS ON ES500 SERIES
SHEETS.
6. SEE ELECTRICAL PANELBOARD SCHEDULES ON EP700
SERIES SHEETS.
7. SEE EXTERIOR LIGHTING CONTACTOR SCHEMATICS ON
SHEET EL502.
KEYED NOTES:
SEE DETAIL A4 ON SHEET ES503 FOR LIGHT POLE BASE
DETAIL.
11 DEC 2020
CONTROLLED UNCLASSIFIED INFORMATION
CONTROLLED UNCLASSIFIED INFORMATION
ARIMS: 200A Disposition: Maintain for 15 yrs after construction
W
2Q R
R
_P la ns _V ol _I
V-
C B
C B
C B
C B
C B
C B
S T
S T
S T
E
E
LP
C B
CP#5
MH
D E
S I G
N E
D
B
Y
M A
R K
D E
S C
R I P
T I O
N D
A T
E
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
F I
M
E
S I Z
E
P L O
T
S
C A
L E
P
L O
T
D
A T
E
I S
S U
E
D
A T
E
P R
O J E
C O
N T
R A
A
W I N
G
C
O D
E
X
S O
L I C
I T
A T
I O
N
N
O
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
L O
U I S
V I L
S
T R
I C
T
L O
U I S
V I L L E
K
E N
T U
C K
Y
W
A R
D
P
A R
K W
A Y
K
A N
S A
S
C
I T
Y
M
O
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
SHEET ID
P R
O J E
K
R S
M
S C
O T
T
A
R
S
E
I L L I N
O I S
J O
I N
T
O
P E
R A
T I O
S
S I O
N
P
L A
N N
I N
G
C
E N
T E
R
J O
M P
C
O
W N
C E
R T
I F
I E
D
F
I N
S
S U
D
1 753 92 864 10
A
B
C
D
E
F
G
C
E R
T I F
I E
D
F
I N
A L
I S
S U
D
D E
C
V D
Y D
ES105
M
H
A R
A L S
O N
P
O
G
O R
M A
N
Z
M
A T
H E
E
S
D
W G
E L E
C T
R I C
A L
S
I T
E
P
L A
N
N
KEY PLAN
NOT TO SCALE
C O
C O
C O
C O
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
F H
F H
F H
F H
F H
F H
F H
E
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
M
A
P
L
E
10 14
A1
ELECTRICAL SITE PLAN 5
SCALE: 1" = 20'-0"
N
20' 40'0
MATCHLINE SEE SHEET ES106 FOR CONTINUATION
NOTES:
1. ROUTING SHOWN IS DIAGRAMMATIC. CONTRACTOR
SHALL ROUTE CONDUITS TO AVOID BUILDING
STRUCTURES AND ALL UTILITIES BELOW AND/OR ABOVE
GRADE. CONTRACTOR SHALL COORDINATE FINAL
LOCATION OF ALL ELECTRICAL AND
TELECOMMUNICATIONS EQUIPMENT WITH OTHER
DISCIPLINES.
2. SEE LIGHT FIXTURE SCHEDULE ON SHEET EL601.
3. SEE ELECTRICAL ONE-LINE DIAGRAMS ON EP600 SERIES
SHEETS.
4. SEE ELECTRICAL SITE DETAILS ON ES500 SERIES
SHEETS.
JOMPC BUILDING
SCOTT DRIVE
W
C
L A
Y
S
T R
E E
T
M A
T C
H L I N
E
S
E
N
T I N
U A
T I O
N
EXISTING LIGHT POLE
TO BE RELOCATED
SEE NEW LIGHT POLE LOCATION ON SHEET ES109.
KEYED NOTES:
C1
EL402
TO PANEL L3 IN
ELECTRICAL ROOM 1105
11 DEC 2020
CONTROLLED UNCLASSIFIED INFORMATION
CONTROLLED UNCLASSIFIED INFORMATION
ARIMS: 200A Disposition: Maintain for 15 yrs after construction
W
2Q R
R
_P la ns _V ol _I
V-
C B
U
E
U
E
U
E
U
E
MH
U E
U E
U E
U E
UE UE UE UE UE UE UE
U E
U E
U E
U E
UE
UE
UE
UE
UE
UE
UE
UE
U
E
UE
U E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
Y4
L1-13
Y4
L1-13
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
UE
D E
S I G
N E
D
B
Y
M A
R K
D E
S C
R I P
T I O
N D
A T
E
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
F I
M
E
S I Z
E
P L O
T
S
C A
L E
P
L O
T
D
A T
E
I S
S U
E
D
A T
E
P R
O J E
C O
N T
R A
A
W I N
G
C
O D
E
X
S O
L I C
I T
A T
I O
N
N
O
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
L O
U I S
V I L
S
T R
I C
T
L O
U I S
V I L L E
K
E N
T U
C K
Y
W
A R
D
P
A R
K W
A Y
K
A N
S A
S
C
I T
Y
M
O
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
SHEET ID
P R
O J E
K
R S
M
S C
O T
T
A
R
S
E
I L L I N
O I S
J O
I N
T
O
P E
R A
T I O
S
S I O
N
P
L A
N N
I N
G
C
E N
T E
R
J O
M P
C
O
W N
C E
R T
I F
I E
D
F
I N
S
S U
D
1 753 92 864 10
A
B
C
D
E
F
G
C
E R
T I F
I E
D
F
I N
A L
I S
S U
D
D E
C
V D
Y D
ES106
M
H
A R
A L S
O N
P
O
G
O R
M A
N
Z
M
A T
H E
E
S
D
W G
E L E
C T
R I C
A L
S
I T
E
P
L A
N
N
KEY PLAN
NOT TO SCALE
C O
C O
C O
C O
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
F H
F H
F H
F H
F H
F H
F H
E
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
M
A
P
L
E
10 14
A1
ELECTRICAL SITE PLAN 6
SCALE: 1" = 20'-0"
N
20' 40'0
M A
T C
H L I N
E
S
E
N
T I N
U A
T I O
N
MATCHLINE SEE SHEET ES107 FOR CONTINUATION
M A
T C
H L I N
E
S
E
N
T I N
U A
T I O
N
2-WAY CONCRETE ENCASED DUCTBANK. 3-500 KCMIL,
MV-105, 35KV, CONCENTRIC NEUTRAL W/ 100% INSULATION
IN 6" SCHEDULE 80 PVC CONDUIT. ONE SPARE 6"
SCHEDULE 80 PVC CONDUIT.
CUT AND PATCH ROADWAY PER CIVIL SPECIFICATIONS TO
MATCH EXISTING.
SEE DETAIL A4 ON SHEET ES503 FOR LIGHT POLE BASE
DETAIL.
SEE SHEETS EL107 AND EL108 FOR ADDITIONAL LIGHTING
FOR THIS AREA. SEE SHEETS EP107 AND EP108 FOR
ADDITIONAL POWER INFORMATION FOR THIS AREA.
SEE DETAIL E7 ON SHEET ES503 FOR TYPICAL BOLLARD
INSTALLATION DETAIL.
SEE SHEET EP108 FOR CONTINUATION.
2-WAY CONCRETE ENCASED DUCTBANK. TWO SPARE 6"
SCHEDULE 80 PVC CONDUITS.
NOTES:
1. ROUTING SHOWN IS DIAGRAMMATIC. CONTRACTOR
SHALL ROUTE CONDUITS TO AVOID BUILDING
STRUCTURES AND ALL UTILITIES BELOW AND/OR ABOVE
GRADE. CONTRACTOR SHALL COORDINATE FINAL
LOCATION OF ALL ELECTRICAL AND
TELECOMMUNICATIONS EQUIPMENT WITH OTHER
DISCIPLINES.
2. SEE LIGHT FIXTURE SCHEDULE ON SHEET EL601.
3. SEE ELECTRICAL ONE-LINE DIAGRAMS ON EP600 SERIES
SHEETS.
4. SEE ELECTRICAL SITE DETAILS ON ES500 SERIES
SHEETS.
5. SEE ELECTRICAL PANELBOARD SCHEDULES ON EP700
SERIES SHEETS.
6. SEE EXTERIOR LIGHTING CONTACTOR SCHEMATICS ON
SHEET EL502.
KEYED NOTES:
MATCHLINE SEE SHEET ES105 FOR CONTINUATION
JOMPC BUILDING
W
C
L A
Y
S
T R
E E
T
NEW 35KV
SWITCHGEAR
LIGHT FIXTURE TYPE P2
L1-15
LIGHT FIXTURE
TYPE Y3
L1-13
(TYP OF 16)
LIGHT FIXTURE TYPE P2
L1-13
LIGHT FIXTURE TYPE P2
L1-15
(TYP)
LIGHT FIXTURE TYPE P2
L1-15
A1
EL402
E1
EL402
TO PANEL L1
IN ELECTRICAL
ROOM 1021
TO PANEL L1
IN ELECTRICAL
ROOM 1021
ES501
A4
A4
ES501
A4
ES501
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
U
E
11 DEC 2020
CONTROLLED UNCLASSIFIED INFORMATION
CONTROLLED UNCLASSIFIED INFORMATION
ARIMS: 200A Disposition: Maintain for 15 yrs after construction
W
2Q R
R
_P la ns _V ol _I
V-
E
E
E
E
E
E
EEEEEEEEEEEEE
C B
C B
C B
C B
C B
C B
C B
C B
CP#4
MH
D E
S I G
N E
D
B
Y
M A
R K
D E
S C
R I P
T I O
N D
A T
E
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
F I
M
E
S I Z
E
P L O
T
S
C A
L E
P
L O
T
D
A T
E
I S
S U
E
D
A T
E
P R
O J E
C O
N T
R A
A
W I N
G
C
O D
E
X
S O
L I C
I T
A T
I O
N
N
O
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
L O
U I S
V I L
S
T R
I C
T
L O
U I S
V I L L E
K
E N
T U
C K
Y
W
A R
D
P
A R
K W
A Y
K
A N
S A
S
C
I T
Y
M
O
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
SHEET ID
P R
O J E
K
R S
M
S C
O T
T
A
R
S
E
I L L I N
O I S
J O
I N
T
O
P E
R A
T I O
S
S I O
N
P
L A
N N
I N
G
C
E N
T E
R
J O
M P
C
O
W N
C E
R T
I F
I E
D
F
I N
S
S U
D
1 753 92 864 10
A
B
C
D
E
F
G
C
E R
T I F
I E
D
F
I N
A L
I S
S U
D
D E
C
V D
Y D
ES107
M
H
A R
A L S
O N
P
O
G
O R
M A
N
Z
M
A T
H E
E
S
D
W G
E L E
C T
R I C
A L
S
I T
E
P
L A
N
N
KEY PLAN
NOT TO SCALE
C O
C O
C O
C O
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
F H
F H
F H
F H
F H
F H
F H
E
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
M
A
P
L
E
10 14
A1
ELECTRICAL SITE PLAN 7
SCALE: 1" = 20'-0"
N
20' 40'0
MATCHLINE SEE SHEET ES108 FOR CONTINUATION
MATCHLINE SEE SHEET ES106 FOR CONTINUATION
M A
T C
H L I N
E
S
E
F
N
T I N
U A
T I O
N
NOTES:
1. ROUTING SHOWN IS DIAGRAMMATIC. CONTRACTOR
SHALL ROUTE CONDUITS TO AVOID BUILDING
STRUCTURES AND ALL UTILITIES BELOW AND/OR ABOVE
GRADE. CONTRACTOR SHALL COORDINATE FINAL
LOCATION OF ALL ELECTRICAL AND
TELECOMMUNICATIONS EQUIPMENT WITH OTHER
DISCIPLINES.
2. SEE LIGHT FIXTURE SCHEDULE ON SHEET EL601.
3. SEE ELECTRICAL ONE-LINE DIAGRAMS ON EP600 SERIES
SHEETS.
4. SEE ELECTRICAL SITE DETAILS ON ES500 SERIES
SHEETS.
5. SEE ELECTRICAL PANELBOARD SCHEDULES ON EP700
SERIES SHEETS.
6. SEE EXTERIOR LIGHTING CONTACTOR SCHEMATICS ON
SHEET EL502.
KEYED NOTES:
SEE DETAIL A4 ON SHEET ES503 FOR LIGHT POLE BASE
DETAIL.
LIGHT FIXTURE TYPE P2
L1-13
LIGHT FIXTURE TYPE P1
L1-13
LIGHT FIXTURE TYPE P2
L1-15
LIGHT FIXTURE TYPE P2
L1-15
LIGHT FIXTURE TYPE P2
L1-15
LIGHT FIXTURE TYPE P2
L1-15
(TYP)
LIGHT FIXTURE TYPE P2
L1-15
LIGHT FIXTURE TYPE P2
L1-15
11 DEC 2020
CONTROLLED UNCLASSIFIED INFORMATION
CONTROLLED UNCLASSIFIED INFORMATION
ARIMS: 200A Disposition: Maintain for 15 yrs after construction
W
2Q R
R
_P la ns _V ol _I
V-
S I G
N E
D
B
Y
M A
R K
D E
S C
R I P
T I O
N D
A T
E
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
F I
M
E
S I Z
E
P L O
T
S
C A
L E
P
L O
T
D
A T
E
I S
S U
E
D
A T
E
P R
O J E
C O
N T
R A
A
W I N
G
C
O D
E
X
S O
L I C
I T
A T
I O
N
N
O
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
L O
U I S
V I L
S
T R
I C
T
L O
U I S
V I L L E
K
E N
T U
C K
Y
W
A R
D
P
A R
K W
A Y
K
A N
S A
S
C
I T
Y
M
O
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
SHEET ID
P R
O J E
K
R S
M
S C
O T
T
A
R
S
E
I L L I N
O I S
J O
I N
T
O
P E
R A
T I O
S
S I O
N
P
L A
N N
I N
G
C
E N
T E
R
J O
M P
C
O
W N
C E
R T
I F
I E
D
F
I N
S
S U
D
1 753 92 864 10
A
B
C
D
E
F
G
C
E R
T I F
I E
D
F
I N
A L
I S
S U
D
D E
C
V D
Y D
ES108
M
H
A R
A L S
O N
P
O
G
O R
M A
N
Z
M
A T
H E
E
S
D
W G
E L E
C T
R I C
A L
S
I T
E
P
L A
N
N
KEY PLAN
NOT TO SCALE
C O
C O
C O
C O
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
F H
F H
F H
F H
F H
F H
F H
E
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
M
A
P
L
E
10 14
A1
ELECTRICAL SITE PLAN 8
SCALE: 1" = 20'-0"
N
20' 40'0
M A
T C
H L I N
E
S
E
F
N
T I N
U A
T I O
N
MATCHLINE SEE SHEET ES107 FOR CONTINUATION
KEYED NOTES:
1. ROUTING SHOWN IS DIAGRAMMATIC. CONTRACTOR
SHALL ROUTE CONDUITS TO AVOID BUILDING
STRUCTURES AND ALL UTILITIES BELOW AND/OR ABOVE
GRADE. CONTRACTOR SHALL COORDINATE FINAL
LOCATION OF ALL ELECTRICAL AND
TELECOMMUNICATIONS EQUIPMENT WITH OTHER
DISCIPLINES.
2. SEE LIGHT FIXTURE SCHEDULE ON SHEET EL601.
3. SEE ELECTRICAL ONE-LINE DIAGRAMS ON EP600 SERIES
SHEETS.
4. SEE ELECTRICAL SITE DETAILS ON ES500 SERIES
SHEETS.
5. SEE ELECTRICAL PANELBOARD SCHEDULES ON EP700
SERIES SHEETS.
6. SEE EXTERIOR LIGHTING CONTACTOR SCHEMATICS ON
SHEET EL502.
LIGHT FIXTURE TYPE P3
L1-13
SEE DETAIL A4 ON SHEET ES503 FOR LIGHT POLE BASE
DETAIL.
NOTES:
11 DEC 2020
CONTROLLED UNCLASSIFIED INFORMATION
CONTROLLED UNCLASSIFIED INFORMATION
ARIMS: 200A Disposition: Maintain for 15 yrs after construction
W
2Q R
R
_P la ns _V ol _I
V-
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
C B
C B
C B
24" PVC
MH
MH
D E
S I G
N E
D
B
Y
M A
R K
D E
S C
R I P
T I O
N D
A T
E
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
F I
M
E
S I Z
E
P L O
T
S
C A
L E
P
L O
T
D
A T
E
I S
S U
E
D
A T
E
P R
O J E
C O
N T
R A
A
W I N
G
C
O D
E
X
S O
L I C
I T
A T
I O
N
N
O
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
L O
U I S
V I L
S
T R
I C
T
L O
U I S
V I L L E
K
E N
T U
C K
Y
W
A R
D
P
A R
K W
A Y
K
A N
S A
S
C
I T
Y
M
O
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
SHEET ID
P R
O J E
K
R S
M
S C
O T
T
A
R
S
E
I L L I N
O I S
J O
I N
T
O
P E
R A
T I O
S
S I O
N
P
L A
N N
I N
G
C
E N
T E
R
J O
M P
C
O
W N
C E
R T
I F
I E
D
F
I N
S
S U
D
1 753 92 864 10
A
B
C
D
E
F
G
C
E R
T I F
I E
D
F
I N
A L
I S
S U
D
D E
C
V D
Y D
ES109
M
H
A R
A L S
O N
P
O
G
O R
M A
N
Z
M
A T
H E
E
S
D
W G
E L E
C T
R I C
A L
S
I T
E
P
L A
N
N
KEY PLAN
NOT TO SCALE
C O
C O
C O
C O
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
F H
F H
F H
F H
F H
F H
F H
E
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
M
A
P
L
E
10 14
A1
ELECTRICAL SITE PLAN 9
SCALE: 1" = 20'-0"
N
20' 40'0
NOTES:
1. ROUTING SHOWN IS DIAGRAMMATIC. CONTRACTOR
SHALL ROUTE CONDUITS TO AVOID BUILDING
STRUCTURES AND ALL UTILITIES BELOW AND/OR ABOVE
GRADE. CONTRACTOR SHALL COORDINATE FINAL
LOCATION OF ALL ELECTRICAL AND
TELECOMMUNICATIONS EQUIPMENT WITH OTHER
DISCIPLINES.
2. SEE LIGHT FIXTURE SCHEDULE ON SHEET EL601.
3. SEE ELECTRICAL ONE-LINE DIAGRAMS ON EP600 SERIES
SHEETS.
4. SEE ELECTRICAL SITE DETAILS ON ES500 SERIES
SHEETS.
M A
T C
H L I N
E
S
E
N
T I N
U A
T I O
N
RELOCATED LIGHT POLE SHALL REMAIN ON EXISTING
CIRCUIT. EXISTING LIGHT POLES ON THE SAME CIRCUIT
SHALL REMAIN OPERATIONAL. SEE EXISTING LIGHT POLE
LOCATION ON SHEET ES105. PROVIDE NEW FOUNDATION
PER DETAIL A4 ON SHEET ES503 WITH ANCHOR BOLT TYPE,
DIAMETER, PLAN LAYOUT, EMBEDMENT LENGTH AND
PROJECTION TO MATCH EXISTING.
KEYED NOTES:
MATCHLINE SEE SHEET ES110 FOR CONTINUATION
RELOCATED LIGHT
POLE
11 DEC 2020
CONTROLLED UNCLASSIFIED INFORMATION
CONTROLLED UNCLASSIFIED INFORMATION
ARIMS: 200A Disposition: Maintain for 15 yrs after construction
W
2Q R
R
_P la ns _V ol _I
V-
C B
C B
MH
MH
UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE
U E
U E
U E
U E
U E
U E
UE UE UE UE UE UE
MH MH
MH
MH
UE
UE
UE
U
E
U
E
D E
S I G
N E
D
B
Y
M A
R K
D E
S C
R I P
T I O
N D
A T
E
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
F I
M
E
S I Z
E
P L O
T
S
C A
L E
P
L O
T
D
A T
E
I S
S U
E
D
A T
E
P R
O J E
C O
N T
R A
A
W I N
G
C
O D
E
X
S O
L I C
I T
A T
I O
N
N
O
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
L O
U I S
V I L
S
T R
I C
T
L O
U I S
V I L L E
K
E N
T U
C K
Y
W
A R
D
P
A R
K W
A Y
K
A N
S A
S
C
I T
Y
M
O
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
SHEET ID
P R
O J E
K
R S
M
S C
O T
T
A
R
S
E
I L L I N
O I S
J O
I N
T
O
P E
R A
T I O
S
S I O
N
P
L A
N N
I N
G
C
E N
T E
R
J O
M P
C
O
W N
C E
R T
I F
I E
D
F
I N
S
S U
D
1 753 92 864 10
A
B
C
D
E
F
G
C
E R
T I F
I E
D
F
I N
A L
I S
S U
D
D E
C
V D
Y D
ES110
M
H
A R
A L S
O N
P
O
G
O R
M A
N
Z
M
A T
H E
E
S
D
W G
E L E
C T
R I C
A L
S
I T
E
P
L A
N
N
KEY PLAN
NOT TO SCALE
C O
C O
C O
C O
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
F H
F H
F H
F H
F H
F H
F H
E
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
M
A
P
L
E
10 14
A1
ELECTRICAL SITE PLAN 10
SCALE: 1" = 20'-0"
N
20' 40'0
NOTES:
1. ROUTING SHOWN IS DIAGRAMMATIC. CONTRACTOR
SHALL ROUTE CONDUITS TO AVOID BUILDING
STRUCTURES AND ALL UTILITIES BELOW AND/OR ABOVE
GRADE. CONTRACTOR SHALL COORDINATE FINAL
LOCATION OF ALL ELECTRICAL AND
TELECOMMUNICATIONS EQUIPMENT WITH OTHER
DISCIPLINES.
2. SEE LIGHT FIXTURE SCHEDULE ON SHEET EL601.
3. SEE ELECTRICAL ONE-LINE DIAGRAMS ON EP600 SERIES
SHEETS.
4. SEE ELECTRICAL SITE DETAILS ON ES500 SERIES
SHEETS.
M A
T C
H L I N
E
S
E
N
T I N
U A
T I O
N
M A
T C
H L I N
E
S
E
N
T I N
U A
T I O
N
2-WAY CONCRETE ENCASED DUCTBANK. 3-500 KCMIL,
MV-105, 35KV, CONCENTRIC NEUTRAL W/ 100% INSULATION
IN 6" SCHEDULE 80 PVC CONDUIT. ONE SPARE 6"
SCHEDULE 80 PVC CONDUIT.
CUT AND PATCH SIDEWALK OR ROADWAY PER CIVIL
SPECIFICATIONS TO MATCH EXISTING.
DEMOLISH AND REMOVE SECTION OF EXISTING
ABANDONED STEAM TUNNEL. CAP ENDS OF REMAINING
SECTIONS. REFER TO SPECIFICATION 02 14 00 AND 02 82 00
AND GENERAL NOTES ON SHEET GC006 FOR ADDITIONAL
INFORMATION.
KEYED NOTES:
1 3
1 2
MATCHLINE SEE SHEET ES109 FOR CONTINUATION
ES501
A4
(TYP, UON)
11 DEC 2020
CONTROLLED UNCLASSIFIED INFORMATION
CONTROLLED UNCLASSIFIED INFORMATION
ARIMS: 200A Disposition: Maintain for 15 yrs after construction
W
2Q R
R
_P la ns _V ol _I
V-
C B
MH
MH
U E
MH
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
U
E
U
E
D E
S I G
N E
D
B
Y
M A
R K
D E
S C
R I P
T I O
N D
A T
E
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
F I
M
E
S I Z
E
P L O
T
S
C A
L E
P
L O
T
D
A T
E
I S
S U
E
D
A T
E
P R
O J E
C O
N T
R A
A
W I N
G
C
O D
E
X
S O
L I C
I T
A T
I O
N
N
O
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
L O
U I S
V I L
S
T R
I C
T
L O
U I S
V I L L E
K
E N
T U
C K
Y
W
A R
D
P
A R
K W
A Y
K
A N
S A
S
C
I T
Y
M
O
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
SHEET ID
P R
O J E
K
R S
M
S C
O T
T
A
R
S
E
I L L I N
O I S
J O
I N
T
O
P E
R A
T I O
S
S I O
N
P
L A
N N
I N
G
C
E N
T E
R
J O
M P
C
O
W N
C E
R T
I F
I E
D
F
I N
S
S U
D
1 753 92 864 10
A
B
C
D
E
F
G
C
E R
T I F
I E
D
F
I N
A L
I S
S U
D
D E
C
V D
Y D
ES114
M
H
A R
A L S
O N
P
O
G
O R
M A
N
Z
M
A T
H E
E
S
D
W G
E L E
C T
R I C
A L
S
I T
E
P
L A
N
N
KEY PLAN
NOT TO SCALE
C O
C O
C O
C O
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
F H
F H
F H
F H
F H
F H
F H
E
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
E M
M
A
P
L
E
10 14
A1
ELECTRICAL SITE PLAN 14
SCALE: 1" = 20'-0"
N
20' 40'0
NOTES:
1. ROUTING SHOWN IS DIAGRAMMATIC. CONTRACTOR
SHALL ROUTE CONDUITS TO AVOID BUILDING
STRUCTURES AND ALL UTILITIES BELOW AND/OR ABOVE
GRADE. CONTRACTOR SHALL COORDINATE FINAL
LOCATION OF ALL ELECTRICAL AND
TELECOMMUNICATIONS EQUIPMENT WITH OTHER
DISCIPLINES.
2. SEE ELECTRICAL ONE-LINE DIAGRAMS ON EP600 SERIES
SHEETS.
3. SEE ELECTRICAL SITE DETAILS ON ES500 SERIES
SHEETS.
M A
T C
H L I N
E
S
E
N
T I N
U A
T I O
N
2-WAY CONCRETE ENCASED DUCTBANK. 3-500 KCMIL,
MV-105, 35KV, CONCENTRIC NEUTRAL W/ 100% INSULATION
IN 6" SCHEDULE 80 PVC CONDUIT. ONE SPARE 6" SCHEDULE
80 PVC CONDUIT.
CUT AND PATCH SIDEWALK PER CIVIL SPECIFICATIONS TO
MATCH EXISTING.
CONNECT TO BUSBARS AND HEATER CIRCUIT OF EXISTING
SWITCHGEAR. COORDINATE SWITCHGEAR SHUTDOWN
WITH COR A MINIMUM OF 90 DAYS PRIOR TO PLANNED
WORK. WORK TO ADD NEW CUBICLE SHALL BE COMPLETED
IN ONE WEEKEND TO MINIMIZE OUTAGE. EXTEND
HOUSEKEEPING PAD TO ACCOMODATE NEW CUBICLE.
REFER TO STRUCTURAL DRAWING SET FOR TYPICAL
EQUIPMENT PAD DETAIL.
BLDG 1575 EXPANSION PROJECT (NOTED FOR REFERENCE
ONLY).
KEYED NOTES:
EXISTING 35KV
SWITCHGEAR
NEW CUBICLE
AND SWITCH
ES501
A4
(TYP, UON)
BLDG 1700
BLDG 1575
11 DEC 2020
CONTROLLED UNCLASSIFIED INFORMATION
CONTROLLED UNCLASSIFIED INFORMATION
ARIMS: 200A Disposition: Maintain for 15 yrs after construction
W
2Q R
R
_P la ns _V ol _I
V-
3000 PSI CONCRETE
3'-0" RADIUS, 5" PVC
SCHEDULE 40 CONCRETE
ENCASED DUCTS.
PROVIDE PULL STRINGS
THE FULL LENGTH OF
EACH SPARE PRIMARY
DUCT.
#4 REINFORCING ROD 6"
O.C. TOP & BOTTOM
(TYP)
SECONDARY
PRIMARY
FINISHED
GRADE
3'-0" RADIUS, 4" PVC SCHEDULE 40
CONCRETE ENCASED DUCTS. (TYP
OF 8)
THREADED GROUNDING BUSHING (TYP)
1" CHAMFER
(TYP ALL 4
SIDES)
10"
4"
3" (TYP)
3"
SIDE LIFTING
INSERTS (4)
5" PRIMARY CONDUIT
WITH END BELL (LOOP
FEED OPTION DASHED)
GROUND
ROD
1 1 1
2 2 2 2
3 3 3 3
4 4 4 4
1 1 1 1
2 2 2 2
3 3 3 3
4 4 4 4
ROW 1
ROW 2
ROW 3
ROW 4
SECONDARY BARRIER
IN TRANSFORMER
TYPICAL SECONDARY CONDUIT DETAIL
COORDINATE ACTUAL CONDUIT CONFIGURATION WITH
ONE-LINE DIAGRAM
6" 5'-0" 6"
6'-0"
A1
COORDINATE CONDUIT
WINDOW LOCATION AND
SIZE WITH TRANSFORMER
BEING PROCURED
NOTES:
1. COORDINATE FINAL PAD SIZE WITH TRANSFORMER BEING FURNISHED.
M
IN
3"
PVC CONDUIT.
SIZE INDICATED
ON SITE PLANS
(TYP)
SELECT BACKFILL
3000 PSI CONCRETE
TOP OF PAVEMENT SUBGRADE OR GRADE
1. USE PLASTIC CONDUIT SPACERS AT 5'-0" OC.
3"
CONDUCTORS PER ONE-LINE
DIAGRAMS
WARNING TAPE, 6" BELOW
GRADE
NOTES:
#4/0AWG BARE
COPPER GROUNDING
CONDUCTOR
SPARE CONDUIT FOR FUTURE.
PROVIDE PULL WIRE.
M
IN
3"
PVC CONDUIT.
SIZE INDICATED
ON SITE PLANS
(TYP)
SPARE CONDUIT FOR FUTURE.
PROVIDE PULL WIRE. (TYP OF 2)
SELECT BACKFILL
3000 PSI CONCRETE
TOP OF PAVEMENT SUBGRADE OR GRADE
1. USE PLASTIC CONDUIT SPACERS
AT 5'-0" OC.
3" 3"
CONDUCTORS PER ONE-LINE
DIAGRAMS
WARNING TAPE, 6" BELOW
GRADE (TYP OF 2 LOCATIONS)
NOTES:
3" 3"
#4/0AWG BARE
COPPER GROUNDING
CONDUCTOR
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
P
L O
T D
A T
E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C
O N
T R
A C
T N
O
A F
D R
A W
IN
G
C O
D E
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
SHEET ID
P R
O J…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .