W912QR20R0004_Plans_Vol_III_(2of3)-0000.pdf

PDF 15 MB Posted

Attached to
Joint Operations Mission and Planning Center (JOMPC), Scott AFB
Solicitation number
W912QR20R0004
Issued by

About this file

This document provides details on a federal solicitation for the Joint Operations Mission and Planning Center (JOMPC) at Scott Air Force Base. The solicitation number is W912QR20R0004 and is being issued by the Department of the Army Corps of Engineers Engineering District Louisville. Interested parties should review the attached solicitation document and previously posted pre-solicitation notice for requirements regarding the JOMPC project. The solicitation seeks to award a contract for construction of the new JOMPC facility at Scott AFB to support mission planning and operations. Responses are due by the date specified in the solicitation document.

View the file

Other files

File Type Posted
W912QR20R0004_Plans-0005.pdf PDF
W912QR20R0004_Specs-0005.pdf PDF
JA - SCO (Basis of Design) - JOMPC (Clean).pdf PDF
W912QR20R0004_SID-0004.pdf PDF
JA - District (Monaco - Brand Name)- JOMPC (Clean).pdf PDF
W912QR20R0004_SiteVisitRoster-0004.pdf PDF
JA - District (Water and Sewer Utilities) - JOMPC (Clean).pdf PDF
JA - SCO (HVAC Chillers - Brand Name) - JOMPC (Clean).pdf PDF
W912QR20R0004_Specs-0004.pdf PDF
JA - SCO (HVAC DDC - Brand Name) - JOMPC (Clean).pdf PDF
JA - District (Security Cameras - Brand Name) - JOMPC (Clean).pdf PDF
JA - District (Vindicator - Brand Name) - JOMPC (Clean).pdf PDF
W912QR20R0004_Plans-0004.pdf PDF
W912QR20R0004_Plans-0003.pdf PDF
W912QR20R0004_Specs_FFE-0003.pdf PDF
W912QR20R0004_Plans-0002.pdf PDF
W912QR20R0004_FFE-0002.pdf PDF
W912QR20R0004_Specs-0002.pdf PDF
W912QR20R0004_FFE-0001.pdf PDF
W912QR20R0004_Plans_Vol_II_(1of3)-0000.pdf PDF
W912QR20R0004_Plans_Vol_I_(3of3)-0000.pdf PDF
W912QR20R0004_SPECS_VOL_I-0000.pdf PDF
W912QR20R0004_Plans_Vol_II_(2of3)-0000.pdf PDF
W912QR20R0004_SID-0000.pdf PDF
W912QR20R0004_Plans_Vol_I_(2of3)-0000.pdf PDF
W912QR20R0004_Plans_Vol_IV-0000.pdf PDF
W912QR20R0004_Plans_Vol_III_(3of3)-0000.pdf PDF
W912QR20R0004_SPECS_VOL_IV-0000.pdf PDF
W912QR20R0004_FFE-0000.pdf PDF
W912QR20R0004_Plans_Vol_V_(1of2)-0000.pdf PDF
W912QR20R0004_Plans_Vol_I_(1of3)-0000.pdf PDF
W912QR20R0004_SPECS_VOL_III-0000.pdf PDF
W912QR20R0004_Plans_Vol_V_(2of2)-0000.pdf PDF
W912QR20R0004_Plans_Vol_II_(3of3)-0000.pdf PDF
W912QR20R0004_Plans_Vol_III_(1of3)-0000.pdf PDF
W912QR20R0004_SPECS_VOL_II-0000.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O J E

C T

N O

K

R S

M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

J O

IN

T

O P

E R

A T

IO

N

S

M

IS

S

IO

N P

L A

N N

IN

G

C E

N T

(J

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

/1

/2

V D

Y D

G-005-2

C L O

U D

O N

J B

R

IC

E

M A

R C

H

P ro je c t N u m b e rG

-0 -2

.D W

G C

O V

E R

V O

L U

M E

I

II

O

F

M A

R K

D E

S C

R

IP

T

IO

N D

A T

EUS Army Corps of Engineers ®

9400 WARD PARKWAY

KANSAS CITY, MO 64114

P2 NUMBER: 476084

JOINT OPERATIONS & MISSION PLANNING CENTER (JOMPC)

LOUISVILLE DISTRICT

SCOTT AIR FORCE BASE, ILLINOIS

PROJECT NUMBER: VDYD1055428

VOLUME III (2 OF 3)

ISSUED DATE: MARCH, 2021

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

08 March 2021

W912QR20R0004

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

8"

CT-102

8"

8"

INHIBITOR

TANK

1/2" 304 SS

OR SCH 80 PVC

CHEMICAL FEED

LINES

8" EQUALIZER

LINE

CT-101

8"

8"M

CV-049

BIOCIDE

TANK

8"

8"

8"

8"

UNDERGROUND

PIPING

DRAIN

OVERFLOW

STANDPIPE

DRAIN

OVERFLOW

STANDPIPE

2" BLOW DOWN

CWP-102

CWP-101

8"

CW

FILTRATION

ASSEMBLY

MIN. 3'

3" 3" 8"

CH-101

8"

CWP-103

M

C V

-0

CH-102

M

C V

-0

PFX-101

M

C V

-0

6" 6"

6" 6" 6" 6"

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

2. PIPING VIEW IS NOT AFFILIATED WITH

BUILDING KEY PLAN.

AV

CHEMICAL

INJECTION QUILLS

AND PORTS

2" MWBFP

SRC

SOLENOID

VALVE

2" MW

FM

8"M

CV-047

M

CV-048

8"M

CV-046

SRC

FM

DRAIN

M W

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A T

E

IS

S

U E

D A

T E

P R

O

JE

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

LI

C

IT

A

T

IO

N N

O

U .S

. A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

LE

K

E N

T U

C K

Y

W A

R D

P A

R K

W A

Y

K A

N S

A S

C

IT

Y

M O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O

JE

C T

N O

. K R

S M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

JO

IN

T O

P E

R A

T

IO

N S

M

IS

S

IO

N

P

LA

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

2/

/2

V D

Y D

M-213

C . D

A Z

E

G . F

A U

S T

N . N

IE

M

A N

N

O C

T O

B E

R

M

-2

.D W

G C

O N

D E

N S

E R

W A

T E

R F

L O

W D

IA

G

R A

M

NTSSCALE:B1 CONDENSER WATER FLOW DIAGRAM

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

D E

C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

1050 CFM

BREAK OUT (L)

4200 - 2200 CFM OA (DCV)

L-07

AHU-101

TO D1

M-221

FROM D1

M-221

VAV-113

20 CFM

70 CFM

CORRIDOR

50 CFM

10 CFM

920 CFM

930 CFM

EXECUTIVE CONF.

VAV-114

1050 CFM

1050 CFM

BREAK OUT (L)

VAV-107

70 CFM

70 CFM

CORRIDOR (1/3)

40 CFM

3080 CFM

3120 CFM

AUDITORIUM

VAV-104

TO A1

M-220

FROM A1

M-220

FROM A1

M-220

TO D1

M-221

EF-107

EAV-101

TO A1

M-220

TO A1

M-220

SA

RA

RA

SA

14,750 CFM

MAX SA

10550 CFM

MAX RA

2720 - 720 CFM

EA (DCV)

CD-01

(430 CFM PRESSURIZATION)

A

B

C

D E

RA

F

TA

TA

RA

CD-30

CD-24

VAV-105

VAV-106

50 CFM

50 CFM

DV OFFICE

VAV-116

600 CFM

600 CFM

BREAK OUT (S)

VAV-110

50 CFM

50 CFM

DV OFFICE

VAV-112

620 CFM

620 CFM

BREAK OUT (S)

VAV-109

90 CFM

90 CFM

FFCC STORAGE

VAV-111

50 CFM

50 CFM

FFCC COLLATERAL

TELECOMM RM.

10 CFM

630 CFM

640 CFM

BREAK OUT (S)

VAV-108

480 CFM

540 CFM

60 CFM

CORRIDOR

FPVAV-103

50 CFM

50 CFM

TELECOMM SEC.

ENTRANCE FAC.

20 CFM

50 CFM

860 CFM

NIPR CAFE / BREAK

ROOM

790 CFM

590 CFM

590 CFM

ELECT. RM.

TO E1

M-220

TO E1

M-220

FROM E1

M-220

RA

SA

FROM D1

M-221

FROM E1

M-220

70 CFM

TA

50 CFM

TA

RA

FROM E1

M-220

360 CFM

TA

B

E

D

RA

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A T

E

IS

S

U E

D A

T E

P R

O

JE

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

LI

C

IT

A

T

IO

N N

O

U .S

. A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

LE

K

E N

T U

C K

Y

W A

R D

P A

R K

W A

Y

K A

N S

A S

C

IT

Y

M O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O

JE

C T

N O

. K R

S M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

JO

IN

T O

P E

R A

T

IO

N S

M

IS

S

IO

N

P

LA

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

2/

/2

V D

Y D

M-220

C . D

A Z

E

G . F

A U

S T

N . N

IE

M

A N

N

O C

T O

B E

R

M

-2

.D W

G A

IR

F

L O

W D

IA

G

R A

M S

A

H U

-1

NTSSCALE:E1 AIRFLOW DIAGRAM - AHU-101 (1/4)

NTSSCALE:A1 AIRFLOW DIAGRAM - AHU-101 (2/4)

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

2. AHU AIRFLOWS SHOWN ARE COOLING

BLOCK LOAD. ROOM AIRFLOWS SHOWN ARE

COOLING PEAK LOAD.

3. FPVAV AIRFLOWS ARE COOLING PEAK

AIRFLOWS.

4. UNCONNECTED ROOM AIRFLOWS ARE

PRESSURIZATION AIR.

SUPPLY AIR (SA)

RETURN AIR (RA)

EXHAUST / TRANSFER AIR (EA / TA)

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

D E

C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

BREAK OUT RM.

TO E1

M-220

VAV-103

70 CFM

CORRIDOR (2/3)

70 CFM

1050 CFM

1050 CFM

BREAK OUT VTC

RM.

VAV-102

70 CFM

CORRIDOR (3/3)

70 CFM

40 CFM

1490 CFM

900 CFM

450 CFM

CORRIDOR

1000 CFM

FPVAV-104

50 CFM

MOTHER'S RM

50 CFM

200 CFM

420 CFM

PROCESSING

220 CFM

VAV-101

55 CFM

55 CFM

SUP. OFF.

25 CFM

25 CFM

VEST.

FROM D1

M-220

TO A1

M-220

190 CFM

1490 CFM

1680 CFM

FFCC LOBBY

140 CFM

140 CFM

A/V

VAV-115

FROM E1

M-220

SA

TO A1

M-221

TA TO

RM 1053

TA FROM

RM 1054

RA

TO A1

M-221

360 CFM TA

A

F

RA

TA

C

TA

G

H

150 CFM

150 CFM

ADMIN.

FPVAV-101

FPVAV-102

500 CFM

500 CFM

RESTRM. (M)

500 CFM

500 CFM

RESTRM. (W)

50 CFM

50 CFM

JAN.

EF-108

FROM D1

M-221

1050 CFM EA

TA

G

CD-25

FROM D1

M-221

TA

H

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A T

E

IS

S

U E

D A

T E

P R

O

JE

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

LI

C

IT

A

T

IO

N N

O

U .S

. A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

LE

K

E N

T U

C K

Y

W A

R D

P A

R K

W A

Y

K A

N S

A S

C

IT

Y

M O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O

JE

C T

N O

. K R

S M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

JO

IN

T O

P E

R A

T

IO

N S

M

IS

S

IO

N

P

LA

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

2/

/2

V D

Y D

M-221

C . D

A Z

E

G . F

A U

S T

A . A

LD

A

N A

O C

T O

B E

R

M

-2

.D W

G A

IR

F

L O

W D

IA

G

R A

M S

A

H U

-1

SCALE:NTSD1 AIRFLOW DIAGRAM - AHU-101 (3/4)

SCALE:NTSA1 AIRFLOW DIAGRAM - AHU-101 (4/4)

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

2. AHU AIRFLOWS SHOWN ARE COOLING

BLOCK LOAD. ROOM AIRFLOWS SHOWN ARE

COOLING PEAK LOAD.

3. FPVAV AIRFLOWS ARE COOLING PEAK

AIRFLOWS.

4. UNCONNECTED ROOM AIRFLOWS ARE

PRESSURIZATION AIR.

SUPPLY AIR (SA)

RETURN AIR (RA)

EXHAUST / TRANSFER AIR (EA / TA)

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

D E

C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

AHU-102

TO D2

M-223

FROM A1

M-222

50 CFM

50 CFM

A3X OFF.

VAV-213

50 CFM

50 CFM

IMA OFF.

50 CFM

50 CFM

DA3X OFF.

TO A1

M-222

475 CFM

185 CFM

1035 CFM

A3X OPEN OFF.

375 CFM

450 CFM

450 CFM

OPT 1

VAV-214

50 CFM

50 CFM

COLLATERAL

TELECOMM ROOM

450 CFM

450 CFM

OPT 2

VAV-210

1395 CFM

50 CFM

50 CFM 50 CFM

300 CFM

CORRIDOR

70 CFM

480 CFM

OPT 3

480 CFM

VAV-203

FROM D2

M-223

50 CFM

SA

TO D2

M-223

TO A1

M-222

2600 CFM OA

L-09 7750 CFM

MAX SA

CD-02

SA

5150 CFM

MAX RA

FROM A1

M-222

TO A2

M-223

(50 CFM PRESSURIZATION)

A

TA

TA

TA

SA

B

C

D

RA

E

G

CD-31

VAV-211

VAV-212

1615 CFM

300 CFM

300 CFM

ELEC. RM.

VAV-215

205 CFM

475 CFM

400 CFM

130 CFM

CORRIDOR (1/2)

FROM D1

M-222

600 CFM

1360 CFM

A6O OPEN OFF.

760 CFM

VAV-208

250 CFM

250 CFM

CONF.

VAV-204

50 CFM

50 CFM

A6O OFF.

VAV-205

50 CFM

50 CFM

DA6O OFF.

50 CFM

50 CFM

IMA OFF.

50 CFM

50 CFM

IMA OFF.

VAV-206

50 CFM

50 CFM

DA3O OFF.

50 CFM

50 CFM

A3O OFF.

TO D1

M-222

135 CFM

135 CFM

BREAK

VAV-207

90 CFM

90 CFM

COPY

225 CFM

895 CFM

1720 CFM

1050 CFM

A3O OPEN OFF.

FROM D1

M-222

FROM D2

M-223

FROM D1

M-222

355 CFM

TA TO A1

M-225

SA

RA

TO D1

M-224

A

TA

TA

C

D

K

RA

RA

E

H

F

VAV-209

VAV-216

VAV-217

TO D1

M-222

TA

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A T

E

IS

S

U E

D A

T E

P R

O

JE

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

LI

C

IT

A

T

IO

N N

O

U .S

. A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

LE

K

E N

T U

C K

Y

W A

R D

P A

R K

W A

Y

K A

N S

A S

C

IT

Y

M O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O

JE

C T

N O

. K R

S M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

JO

IN

T O

P E

R A

T

IO

N S

M

IS

S

IO

N

P

LA

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

2/

/2

V D

Y D

M-222

C . D

A Z

E

G . F

A U

S T

A . A

LD

A

N A

O C

T O

B E

R

M

-2

.D W

G A

IR

F

L O

W D

IA

G

R A

M S

A

H U

-1

SCALE:NTSD1 AIRFLOW DIAGRAM - AHU-102 (1/4)

SCALE:NTSA1 AIRFLOW DIAGRAM - AHU-102 (2/4)

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

2. AHU AIRFLOWS SHOWN ARE COOLING

BLOCK LOAD. ROOM AIRFLOWS SHOWN ARE

COOLING PEAK LOAD.

3. FPVAV AIRFLOWS ARE COOLING PEAK

AIRFLOWS.

4. UNCONNECTED ROOM AIRFLOWS ARE

PRESSURIZATION AIR.

SUPPLY AIR (SA)

RETURN AIR (RA)

EXHAUST / TRANSFER AIR (EA / TA)

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

D E

C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

FROM D1

M-222

800 CFM

BRIEFING RM.

800 CFM

VAV-201

130 CFM

BREAK RM.

130 CFM

VAV-202

215 CFM

215 CFM

CONF. RM.

315 CFM

370 CFM

55 CFM

HALL

TO A1

M-222

TO D1

M-222

50 CFM

SA

FROM D1

M-222

SA

B

K

RA

TA

C

FROM D1

M-222

330 CFM

330 CFM

ELECT. CLST.

TO A1

M-225

475 CFM

475 CFM

RESTRM. (M)

600 CFM

600 CFM

MECH. RM.

EA

TA

G

L

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A T

E

IS

S

U E

D A

T E

P R

O

JE

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

LI

C

IT

A

T

IO

N N

O

U .S

. A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

LE

K

E N

T U

C K

Y

W A

R D

P A

R K

W A

Y

K A

N S

A S

C

IT

Y

M O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O

JE

C T

N O

. K R

S M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

JO

IN

T O

P E

R A

T

IO

N S

M

IS

S

IO

N

P

LA

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

2/

/2

V D

Y D

M-223

C . D

A Z

E

G . F

A U

S T

A . A

LD

A

N A

O C

T O

B E

R

M

-2

.D W

G A

IR

F

L O

W D

IA

G

R A

M S

A

H U

-1

NTSSCALE:D2 AIRFLOW DIAGRAM - AHU-102 (3/4)

NTSSCALE:A2 AIRFLOW DIAGRAM - AHU-102 (4/4)

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

2. AHU AIRFLOWS SHOWN ARE COOLING

BLOCK LOAD. ROOM AIRFLOWS SHOWN ARE

COOLING PEAK LOAD.

3. FPVAV AIRFLOWS ARE COOLING PEAK

AIRFLOWS.

4. UNCONNECTED ROOM AIRFLOWS ARE

PRESSURIZATION AIR.

SUPPLY AIR (SA)

RETURN AIR (RA)

EXHAUST / TRANSFER AIR (EA / TA)

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

D E

C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

AHU-103

TO D1

M-225

FROM A1

M-224

70 CFM

205 CFM

320 CFM

185 CFM

CORRIDOR (2/2)

125 CFM

125 CFM

FACILITY OFFICE

VAV-312

860 CFM

1280 CFM

COMMANDER'S

BATTLE STAFF

230 CFM

VAV-30950 CFM

MOTHER'S RM.

500 CFM

500 CFM

SIPR VTC CONF.

RM.

VAV-307

50 CFM

50 CFM

COLLATERAL

TELECOMM ROOM

55 CFM

55 CFM

A2X DC OFF.

55 CFM

55 CFM

A2X DDC OFF.

55 CFM

55 CFM

A2F DS OFF.

55 CFM

55 CFM

A2F DDC OFF.

55 CFM

55 CFM

A2F DC OFF.

TO A1

M-224

330 CFM

140 CFM

BREAK

FROM A1

M-225

FROM D1

M-225

2100 CFM OA

L-09 9000 CFM

MAX SA

CD-03

FROM A1

M-222 TO A6

M-224

TO A1

M-224

TO A1

M-225

(420 CFM PRESSURIZATION)

SA

SA

RA

RA

RA

M

N

P

R

S

H T

6900 CFM

MAX RA

CD-32

75 CFM

SA

100 CFM

CUSTODIANS

OFFICE

VAV-310 VAV-308

TA

TA

75 CFM

75 CFM

CATV ROOM

TO A6

M-224

TA

TO A1

M-224

TA

200 CFM

545 CFM

75 CFM

260 CFM

CORRIDOR

1180 CFM

VAV-304

-15 CFM

150 CFM

135 CFM

UPS

VAV-311

780 CFM

1325 CFM

A2X / A2F

545 CFM

TO E1

M-225

TO D1

M-224

EF-204

150 CFM EA

TO A1

M-225

FROM D1

M-224

N

VAV-305

VAV-306

PFROM D1

M-225

390 CFM

SA

TA

SA

TA RA

FROM D1

M-224

TA

230 CFM

TO A6

M-224

TA

-150 CFM

880 CFM

200 CFM

RECEIVING

FROM D1

M-224

EF-110

TA

930 CFM EA

L-09

CD-02

260 CFM

270 CFM

FACILITY STORAGE

FROM D1

M-224

200 CFM

TA

T

50 CFM

50 CFM

MAIL

FROM A1

M-224

260 CFM

TA

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A T

E

IS

S

U E

D A

T E

P R

O

JE

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

LI

C

IT

A

T

IO

N N

O

U .S

. A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

LE

K

E N

T U

C K

Y

W A

R D

P A

R K

W A

Y

K A

N S

A S

C

IT

Y

M O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O

JE

C T

N O

. K R

S M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

JO

IN

T O

P E

R A

T

IO

N S

M

IS

S

IO

N

P

LA

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

2/

/2

V D

Y D

M-224

C . D

A Z

E

G . F

A U

S T

A . A

LD

A

N A

O C

T O

B E

R

M

-2

.D W

G A

IR

F

L O

W D

IA

G

R A

M S

A

H U

-1

SCALE:NTSD1 AIRFLOW DIAGRAM - AHU-103 (1/5)

SCALE:NTSA1 AIRFLOW DIAGRAM - AHU-103 (2/5)

SCALE:NTSA6 AIRFLOW DIAGRAM - AHU-103 (3/5)

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

2. AHU AIRFLOWS SHOWN ARE COOLING

BLOCK LOAD. ROOM AIRFLOWS SHOWN ARE

COOLING PEAK LOAD.

3. FPVAV AIRFLOWS ARE COOLING PEAK

AIRFLOWS.

4. UNCONNECTED ROOM AIRFLOWS ARE

PRESSURIZATION AIR.

SUPPLY AIR (SA)

RETURN AIR (RA)

EXHAUST / TRANSFER AIR (EA / TA)

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

D E

C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

M-224

TO D1

M-224

70 CFM

70 CFM

HALL

VAV-303

30 CFM

450 CFM

800 CFM

320 CFM

MULTIPURPOSE

RM.

310 CFM

310 CFM

SECURITY

VAV-302 FPVAV-303

190 CFM

2610 CFM

2800 CFM

LOBBY

220 CFM

220 CFM

CONF.

VAV-301

30 CFM

420 CFM

390 CFM

ELEV. LOBBY

310 CFM

310 CFM

ELEC. RM.

M

S

SA

RA

TO A1

M-224

TA

FPVAV-301

FPVAV-302

50 CFM

50 CFM

TELECOMM MAIN

ENTRANCE FAC.

FROM A2

M-223

330 CFM

330 CFM

ELECT. CLST.

FROM D1

M-224

60 CFM

60 CFM

JAN.

120 CFM

120 CFM

RESTRM.

400 CFM

500 CFM

100 CFM

RESTRM. (W)

FROM A1

M-224

EF-102

3315 CFM EA

450 CFM

450 CFM

RESTRM. (M)

450 CFM

450 CFM

RESTRM. (W)

330 CFM

TA

1180 CFM

TA

L

CD-12

L-05

EA

FROM A1

M-222F

TA

TA

TA

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A T

E

IS

S

U E

D A

T E

P R

O

JE

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

LI

C

IT

A

T

IO

N N

O

U .S

. A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

LE

K

E N

T U

C K

Y

W A

R D

P A

R K

W A

Y

K A

N S

A S

C

IT

Y

M O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O

JE

C T

N O

. K R

S M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

JO

IN

T O

P E

R A

T

IO

N S

M

IS

S

IO

N

P

LA

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

2/

/2

V D

Y D

M-225

C . D

A Z

E

G . F

A U

S T

A . A

LD

A

N A

O C

T O

B E

R

M

-2

.D W

G A

IR

F

L O

W D

IA

G

R A

M S

A

H U

-1

SCALE:NTSD1 AIRFLOW DIAGRAM - AHU-103 (4/5)

SCALE:NTSA1 AIRFLOW DIAGRAM - AHU-103 (5/5)

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

2. AHU AIRFLOWS SHOWN ARE COOLING

BLOCK LOAD. ROOM AIRFLOWS SHOWN ARE

COOLING PEAK LOAD.

3. FPVAV AIRFLOWS ARE COOLING PEAK

AIRFLOWS.

4. UNCONNECTED ROOM AIRFLOWS ARE

PRESSURIZATION AIR.

SUPPLY AIR (SA)

RETURN AIR (RA)

EXHAUST / TRANSFER AIR (EA / TA)

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

D E

C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

165 CFM

165 CFM

HALL

VAV-403

50 CFM

50 CFM

FFCC SECURED

TELECOMM ROOM

VAV-402

300 CFM

300 CFM

ELECT. RM.

280 CFM

280 CFM

BREAK OUT (S)

VAV-401

30 CFM

30 CFM

VEST

50 CFM

50 CFM

DV OFF.

VAV-413

165 CFM

250 CFM

85 CFM

ADMIN.

290 CFM

290 CFM

BREAK OUT (S)

VAV-405

TO D1

M-226

FROM D1

M-226

SA

A

C

1190 CFM

800 CFM 720 CFM

300 CFM

EXECUTIVE CONF.

30 CFM

290 CFM

290 CFM

BREAK OUT (S)

VAV-404

2200 CFM OA

L-08

AHU-104

10 CFM

470 CFM

480 CFM

WORK ROOM

VAV-408

20 CFM

760 CFM

780 CFM

BREAK OUT (L)

VAV-411

10 CFM

670 CFM

680 CFM

BREAK OUT (L)

VAV-412

10 CFM

690 CFM

700 CFM

BREAK OUT (L)

VAV-410

640 CFM

640 CFM

BREAK OUT (L)

VAV-409

900 CFM

900 CFM

WORK ROOM

VAV-407 60 CFM

VEST.

60 CFM

VAV-406

200 CFM

CONF. RM.

200 CFM

200 CFM

CONF. RM.

200 CFM

FROM A1

M-226

TO A1

M-226

7250 CFM

MAX SA

5050 CFM

MAX RA

(130 CFM

PRESSURIZATION)

A

B

C

RA

RA

SA

TO A1

M-229

CD-04

CD-33

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A T

E

IS

S

U E

D A

T E

P R

O

JE

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

LI

C

IT

A

T

IO

N N

O

U .S

. A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

LE

K

E N

T U

C K

Y

W A

R D

P A

R K

W A

Y

K A

N S

A S

C

IT

Y

M O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O

JE

C T

N O

. K R

S M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

JO

IN

T O

P E

R A

T

IO

N S

M

IS

S

IO

N

P

LA

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

2/

/2

V D

Y D

M-226

C . D

A Z

E

G . F

A U

S T

A . A

LD

A

N A

O C

T O

B E

R

M

-2

.D W

G A

IR

F

L O

W D

IA

G

R A

M S

A

H U

-1

SCALE:NTSA1 AIRFLOW DIAGRAM - AHU-104 (2/2)

SCALE:NTSD1 AIRFLOW DIAGRAM - AHU-104 (1/2)

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

2. AHU AIRFLOWS SHOWN ARE COOLING

BLOCK LOAD. ROOM AIRFLOWS SHOWN ARE

COOLING PEAK LOAD.

3. FPVAV AIRFLOWS ARE COOLING PEAK

AIRFLOWS.

4. UNCONNECTED ROOM AIRFLOWS ARE

PRESSURIZATION AIR.

SUPPLY AIR (SA)

RETURN AIR (RA)

EXHAUST / TRANSFER AIR (EA / TA)

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

D E

C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

3600 CFM OA

L-08

AHU-105

TO D1

M-228

450 CFM

450 CFM

A20

VAV-519

FROM D1

M-228

TO A1

M-227

TO A1

M-228

150 CFM

150 CFM

JWICS CONF. RM

VAV-507

50 CFM

50 CFM

SECURITY

EQUIPMENT RM.

VAV-506

35 CFM

35 CFM

SEC. VEST.

70 CFM

70 CFM

SECURITY

870 CFM

870 CFM

JWICS VTC CONF.

RM.

VAV-505

FROM A1

M-227

FROM A1

M-228

FROM D1

M-229

TO A1

M-227

11,000 CFM

MAX SA

SA

240 CFM

240 CFM

MDT

VAV-508

CD-05

(230 CFM PRESSURIZATION)

7400 CFM

MAX RA

SA

D E

F

G H J

SA

RA RA RA

K

RA

RA

L

CD-34

TO A1

M-227

SA

45 CFM

FROM D1

M-227

TO D1

M-227

40 CFM

370 CFM

CFM

890 CFM

CORRIDOR

VAV-525

50 CFM

50 CFM

OFFICE

50 CFM

50 CFM

OFFICE

50 CFM

50 CFM

OFFICE

TO D1

M-229

VAV-517

10 CFM

30 CFM

400 CFM

380 CFM

NOC ZONE A

VAV-516

10 CFM

1200 CFM

1300 CFM

COS / AMC COM.

CTR.

90 CFM

10 CFM

50 CFM

60 CFM

OFFICE

10 CFM

20 CFM

NOC STOR.

10 CFM

20 CFM

NOC STORAGE

20 CFM

VAV-515

70 CFM

70 CFM

TRAIN.

50 CFM

HALL

50 CFM

60 CFM

60 CFM

HALL

FROM D1

M-227

SA

VAV-518

700 CFM

700 CFM

NOC ZONE B

D

SA

M

L

TO A1

M-229N

200 CFM

TA

370 CFM

370 CFM

ELECT. RM.

S

FROM D1

M-228 R

FROM D1

M-229 P

RA

TO A1

M-229

TA

G

FROM D1

M-227

SA

45 CFM

TA

TA

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A T

E

IS

S

U E

D A

T E

P R

O

JE

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

LI

C

IT

A

T

IO

N N

O

U .S

. A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

LE

K

E N

T U

C K

Y

W A

R D

P A

R K

W A

Y

K A

N S

A S

C

IT

Y

M O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O

JE

C T

N O

. K R

S M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

JO

IN

T O

P E

R A

T

IO

N S

M

IS

S

IO

N

P

LA

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

2/

/2

V D

Y D

M-227

C . D

A Z

E

G . F

A U

S T

A . A

LD

A

N A

O C

T O

B E

R

M

-2

.D W

G A

IR

F

L O

W D

IA

G

R A

M S

A

H U

-1

SCALE:NTSD1 AIRFLOW DIAGRAM - AHU-105 (1/6)

SCALE:NTSA1 AIRFLOW DIAGRAM - AHU-105 (2/6)

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

2. AHU AIRFLOWS SHOWN ARE COOLING

BLOCK LOAD. ROOM AIRFLOWS SHOWN ARE

COOLING PEAK LOAD.

3. FPVAV AIRFLOWS ARE COOLING PEAK

AIRFLOWS.

4. UNCONNECTED ROOM AIRFLOWS ARE

PRESSURIZATION AIR.

SUPPLY AIR (SA)

RETURN AIR (RA)

EXHAUST / TRANSFER AIR (EA / TA)

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

D E

C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

M-227

TO D1

M-227

495 CFM

495 CFM

SECURE RM.

VAV-524

135 CFM

135 CFM

SECURITY

VAV-521

160 CFM

160 CFM

JWICS CAFE

VAV-520

10 CFM

515 CFM

525 CFM

CONF. RM.

VAV-526

630 CFM

630 CFM

BATTLEWATCH

VAV-523

680 CFM

680 CFM

SECURE CONF. RM.

VAV-522

150 CFM

150 CFM

WORK AREA

SA

E

RA

H

FROM D1

M-227

50 CFM

50 CFM

SEA OFF.

VAV-501

50 CFM

50 CFM

D.O. OFF.

100 CFM

100 CFM

CORRIDOR

VAV-504

80 CFM

80 CFM

JWICS A/V RM.

VAV-502

70 CFM

MAIL / COPY

VAV-503

TO D1

M-227

50 CFM

50 CFM

S. COM. OFF.

170 CFM

AIS FRONT OFFICE

240 CFM

SA

RA

F

K

TO A1

M-227

TA

R

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A T

E

IS

S

U E

D A

T E

P R

O

JE

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

LI

C

IT

A

T

IO

N N

O

U .S

. A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

LE

K

E N

T U

C K

Y

W A

R D

P A

R K

W A

Y

K A

N S

A S

C

IT

Y

M O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O

JE

C T

N O

. K R

S M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

JO

IN

T O

P E

R A

T

IO

N S

M

IS

S

IO

N

P

LA

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

2/

/2

V D

Y D

M-228

C . D

A Z

E

G . F

A U

S T

A . A

LD

A

N A

O C

T O

B E

R

M

-2

.D W

G A

IR

F

L O

W D

IA

G

R A

M S

A

H U

-1

SCALE:NTSA1 AIRFLOW DIAGRAM - AHU-105 (4/6)

SCALE:NTSD1 AIRFLOW DIAGRAM - AHU-105 (3/6)

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

2. AHU AIRFLOWS SHOWN ARE COOLING

BLOCK LOAD. ROOM AIRFLOWS SHOWN ARE

COOLING PEAK LOAD.

3. FPVAV AIRFLOWS ARE COOLING PEAK

AIRFLOWS.

4. UNCONNECTED ROOM AIRFLOWS ARE

PRESSURIZATION AIR.

SUPPLY AIR (SA)

RETURN AIR (RA)

EXHAUST / TRANSFER AIR (EA / TA)

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

D E

C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

EAV-401

EAV-501

5440 CFM EA

EAV-502

EAV-503

EAV-504

100 CFM

100 CFM

RESTRM.

100 CFM

100 CFM

BREAK RM.

FROM A1

M-227

TA

N

200 CFM

200 CFM

ELECT. RM.

50 CFM

50 CFM

JAN.

FROM A1

M-227

TA

S

FROM D1

M-226

RA

B

FROM D1

M-229

RA

T

320 CFM

320 CFM

RESTRM. (M)

320 CFM

320 CFM

RESTRM. (W)

EF-101

L-04

CD-13

FROM A1

M-227

315 CFM

650 CFM

BREAK RM.

335 CFM

VAV-509

50 CFM

50 CFM

OFFICE

VAV-514

10 CFM

70 CFM

355 CFM

1130 CFM

835 CFM

A2A

VAV-512

10 CFM

80 CFM

GRAPHICS WORK

SPACE

70 CFM

FPVAV-501

50 CFM

50 CFM

OFFICE

10 CFM

990 CFM

645 CFM

20 CFM

A2X

355 CFM

VAV-510

50 CFM

50 CFM

OFFICE

VAV-527

20 CFM

20 CFM

HALL

50 CFM

COPY

50 CFM

SA

50 CFM

50 CFM

SECURE SERVER

RM.

TO D1

M-227

TO A1

M-227

M

RA

TA

P

J

TO A1

M-229

RA

T

VAV-513 VAV-511

50 CFM

50 CFM

SECURE

TELECOMM ROOM

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A T

E

IS

S

U E

D A

T E

P R

O

JE

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

LI

C

IT

A

T

IO

N N

O

U .S

. A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

LE

K

E N

T U

C K

Y

W A

R D

P A

R K

W A

Y

K A

N S

A S

C

IT

Y

M O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O

JE

C T

N O

. K R

S M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

JO

IN

T O

P E

R A

T

IO

N S

M

IS

S

IO

N

P

LA

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

2/

/2

V D

Y D

M-229

C . D

A Z

E

G . F

A U

S T

A . A

LD

A

N A

O C

T O

B E

R

M

-2

.D W

G A

IR

F

L O

W D

IA

G

R A

M S

A

H U

-1

SCALE:NTSA1 AIRFLOW DIAGRAM - AHU-105 (6/6)

SCALE:NTSD1 AIRFLOW DIAGRAM - AHU-105 (5/6)

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

2. AHU AIRFLOWS SHOWN ARE COOLING

BLOCK LOAD. ROOM AIRFLOWS SHOWN ARE

COOLING PEAK LOAD.

3. FPVAV AIRFLOWS ARE COOLING PEAK

AIRFLOWS.

4. UNCONNECTED ROOM AIRFLOWS ARE

PRESSURIZATION AIR.

SUPPLY AIR (SA)

RETURN AIR (RA)

EXHAUST / TRANSFER AIR (EA / TA)

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

D E

C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

5800 CFM OA

L-09

AHU-201

TO E1

M-231

TO E1

M-232

TO A1

M-231

TO B1

M-232

145 CFM

195 CFM

50 CFM

COMMANDER

VAV-608

510 CFM

510 CFM

AOC COMMAND

SUITE

FPVAV-601

165 CFM

165 CFM

CONF. RM.

VAV-605

60 CFM

60 CFM

SAFETY REP.

VAV-604

60 CFM

60 CFM

CHIEF OF STAFF

60 CFM

60 CFM

CM SGT OFF.

VAV-603

195 CFM

195 CFM

COPY

VAV-606

175 CFM

175 CFM

CONF. RM.

VAV-607

60 CFM

60 CFM

IMA O-6

60 CFM

240 CFM

300 CFM

CORRIDOR

VAV-641

1200 CFM

1200 CFM

LOBBY

VAV-601

70 CFM

70 CFM

JA

50 CFM

195 CFM

145 CFM

VICE COMMANDER

VAV-609

60 CFM

60 CFM

M. ASSIST. OFF.

VAV-610

22,000 CFM

MAX SA

16,200 CFM

MAX RA

SA

TO A1

M-232

(1070 CFM PRESSURIZATION)

A

B C

D

E

SA

SA SA

SA

CD-06

FPVAV-602

FROM E1

M-231

RA

F FROM E1

M-232

RA

G

100 CFM

100 CFM

RESTRM.

TO A1

M-232

EA

H

TO A1

M-231

CD-35

60 CFM

60 CFM

R.A. OFFICE

VAV-602

60 CFM

60 CFM

G.A. OFFICE

TO A1

M-230

TA

N

350 CFM

350 CFM

ELECT. RM.

550 CFM

550 CFM

RESTRM. (M)

350 CFM

350 CFM

MECH. RM.

550 CFM

550 CFM

RESTRM. (W)

60 CFM

60 CFM

JAN.

350 CFM

350 CFM

ELECT. RM.

125 CFM

125 CFM

RESTRM.

115 CFM

115 CFM

MOTHER'S RM.

350 CFM

350 CFM

ELECT. RM.

20 CFM

2370 CFM

450 CFM

2800 CFM

CORRIDOR

FROM E1

M-231

J

FROM E1

M-231

K

SA

SA

FROM E1

M-231

L

FROM A1

M-231

M

TA

TA

EF-202

2800 CFM EACD-27

FROM C1

M-231

N

TA

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A T

E

IS

S

U E

D A

T E

P R

O

JE

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

LI

C

IT

A

T

IO

N N

O

U .S

. A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

LE

K

E N

T U

C K

Y

W A

R D

P A

R K

W A

Y

K A

N S

A S

C

IT

Y

M O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O

JE

C T

N O

. K R

S M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

JO

IN

T O

P E

R A

T

IO

N S

M

IS

S

IO

N

P

LA

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

2/

/2

V D

Y D

M-230

C . D

A Z

E

G . F

A U

S T

A . A

LD

A

N A

O C

T O

B E

R

M

-2

.D W

G A

IR

F

L O

W D

IA

G

R A

M S

A

H U

-2

SCALE:NTSC1 AIRFLOW DIAGRAM - AHU-201 (1/7)

SCALE:NTSA1 AIRFLOW DIAGRAM - AHU-201 (2/7)

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

2. AHU AIRFLOWS SHOWN ARE COOLING

BLOCK LOAD. ROOM AIRFLOWS SHOWN ARE

COOLING PEAK LOAD.

3. FPVAV AIRFLOWS ARE COOLING PEAK

AIRFLOWS.

4. UNCONNECTED ROOM AIRFLOWS ARE

PRESSURIZATION AIR.

SUPPLY AIR (SA)

RETURN AIR (RA)

EXHAUST / TRANSFER AIR (EA / TA)

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

D E

C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

FROM C1

M-230

1200 CFM

1200 CFM

BRIEFING RM.

VAV-626

1200 CFM

1200 CFM

MAIN CONF. RM.

VAV-627

60 CFM

60 CFM

ALD DIR. OFF.

VAV-632

60 CFM

60 CFM

ARD DIR. OFF.

VAV-633

60 CFM

60 CFM

ARD DD OFF.

60 CFM

60 CFM

ALD DD OFF.

60 CFM

60 CFM

ALD EXEC. OFF.

210 CFM

1165 CFM

3775 CFM

2400 CFM

AOC OPEN OFFICE

- NORTHWEST

C

SA

FPVAV-607

FPVAV-608

VAV-635

VAV-636

VAV-637

60 CFM

60 CFM

ARD EXEC. OFF.

VAV-634

60 CFM

60 CFM

ARD EXEC. OFF.

TO A1

M-230

TA

M

TO E1

M-231

RA

R

FROM C1

M-230

170 CFM

170 CFM

A/V OPERATORS

VAV-625

80 CFM

80 CFM

HALL

VAV-628

60 CFM

60 CFM

O-5/GS-14 OFF.

VAV-631

60 CFM

60 CFM

O-6/GS-15 OFF.

150 CFM

965 CFM

2875 CFM

1760 CFM

AOC OPEN OFFICE

- NORTHEAST

20 CFM

40 CFM

60 CFM

O-5/GS-14 OFF.

VAV-630

20 CFM

40 CFM

60 CFM

O-5/GS-14 OFF.

20 CFM

40 CFM

60 CFM

O-5/GS-14 OFF.

20 CFM

40 CFM

60 CFM

O-5/GS-14 OFF.

50 CFM

50 CFM

COLLATERAL

TELECOMM ROOM

FPVAV-611

TO A1

M-230

SA

B

VAV-638

VAV-639

VAV-640

TO A1

M-230

TA

L

TO C1

M-230

RA

F FROM A1

M-231

RA

R

SA

K

TO A1

M-230

SA

J

FPVAV-609

VAV-629

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A T

E

IS

S

U E

D A

T E

P R

O

JE

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

LI

C

IT

A

T

IO

N N

O

U .S

. A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

LE

K

E N

T U

C K

Y

W A

R D

P A

R K

W A

Y

K A

N S

A S

C

IT

Y

M O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O

JE

C T

N O

. K R

S M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

JO

IN

T O

P E

R A

T

IO

N S

M

IS

S

IO

N

P

LA

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

2/

/2

V D

Y D

M-231

C . D

A Z

E

G . F

A U

S T

A . A

LD

A

N A

O C

T O

B E

R

M

-2

.D W

G A

IR

F

L O

W D

IA

G

R A

M S

A

H U

-2

SCALE:NTSA1 AIRFLOW DIAGRAM - AHU-201 (4/7)

SCALE:NTSE1 AIRFLOW DIAGRAM - AHU-201 (3/7)

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

2. AHU AIRFLOWS SHOWN ARE COOLING

BLOCK LOAD. ROOM AIRFLOWS SHOWN ARE

COOLING PEAK LOAD.

3. FPVAV AIRFLOWS ARE COOLING PEAK

AIRFLOWS.

4. UNCONNECTED ROOM AIRFLOWS ARE

PRESSURIZATION AIR.

SUPPLY AIR (SA)

RETURN AIR (RA)

EXHAUST / TRANSFER AIR (EA / TA)

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

D E

C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

VAV-611

FROM C1

M-230

SA

D

80 CFM

80 CFM

1ST SGT OFF.

VAV-616

VAV-617

150 CFM

955 CFM

2410 CFM

1305 CFM

AOC OPEN OFFICE

- SOUTHWEST

TO A1

M-232

TA

W

FPVAV-610 TO A1

M-232

SA

X

VAV-615

60 CFM

60 CFM

SRD DIR. OFF.

60 CFM

60 CFM

SRD DD OFF.

VAV-614

80 CFM

80 CFM

IMA OFF.

VAV-612

40 CFM

440 CFM

340 CFM

CS DIR. OFF.

FPVAV-603

140 CFM

COPY

100 CFM

RESTRM.

FPVAV-604

30 CFM

180 CFM

310 CFM

DEPUTY A3

TO A1

M-232

EA

Y

T0 E1 M-232

RA

V

FPVAV-605

FROM C1

M-230

500 CFM

390 CFM

CS FRONT OFF.

VAV-624 110 CFM

COPY / COFFEE

60 CFM

60 CFM

CS DD OFF.

VAV-623

215 CFM

215 CFM

SHARED

CONFERENCE RM.

VAV-622

60 CFM

60 CFM

CCQ/CCEA CMDR

VAV-621

60 CFM

60 CFM

CS DIR. OFF.

60 CFM

60 CFM

CS SUP. OFF.

60 CFM

60 CFM

UDM OFF.

60 CFM

60 CFM

CCQ/CCEA OFF.

60 CFM

60 CFM

ACOMS DD OFF.

VAV-620

60 CFM

60 CFM

ACOMS DIR. OFF.

150 CFM

1375 CFM

2830 CFM

1305 CFM

AOC OPEN OFFICE

- SOUTHEAST

50 CFM

50 CFM

COLLATERAL

TELECOMM RM.

60 CFM

60 CFM

ACOMS EXEC. OFF.

900 CFM

ELECT. RM.

900 CFM

TO C1

M-230

SA

FPVAV-606

VAV-618

VAV-619

TO A1

M-232

TA

FROM B1

M-232

RA RA

A

G

S

T

V

EF-201

1930 CFM EA

350 CFM

350 CFM

ELECT. RM.

515 CFM

515 CFM

RESTRM. (W)

515 CFM

515 CFM

RESTRM. (M)

FROM C1

M-230

H

FROM B1

M-232

Y

100 CFM EA

100 CFM EA

100 CFM

1430 CFM

400 CFM

1730 CFM

CORRIDOR

FROM C1

M-230

E

FROM B1

M-232

X

SA

SA

FROM E1

M-232

T

FROM B1

M-232

W

TA

TA

350 CFM

350 CFM

ELECT. RM.

CD-26

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A T

E

IS

S

U E

D A

T E

P R

O

JE

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

LI

C

IT

A

T

IO

N N

O

U .S

. A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

LE

K

E N

T U

C K

Y

W A

R D

P A

R K

W A

Y

K A

N S

A S

C

IT

Y

M O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O

JE

C T

N O

. K R

S M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

JO

IN

T O

P E

R A

T

IO

N S

M

IS

S

IO

N

P

LA

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

2/

/2

V D

Y D

M-232

C . D

A Z

E

G . F

A U

S T

A . A

LD

A

N A

O C

T O

B E

R

M

-2

.D W

G A

IR

F

L O

W D

IA

G

R A

M S

A

H U

-2

SCALE:NTSB1 AIRFLOW DIAGRAM - AHU-201 (6/7)

SCALE:NTSE1 AIRFLOW DIAGRAM - AHU-201 (5/7)

SCALE:NTSA1 AIRFLOW DIAGRAM - AHU-201 (7/7)

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

2. AHU AIRFLOWS SHOWN ARE COOLING

BLOCK LOAD. ROOM AIRFLOWS SHOWN ARE

COOLING PEAK LOAD.

3. FPVAV AIRFLOWS ARE COOLING PEAK

AIRFLOWS.

4. UNCONNECTED ROOM AIRFLOWS ARE

PRESSURIZATION AIR.

SUPPLY AIR (SA)

RETURN AIR (RA)

EXHAUST / TRANSFER AIR (EA / TA)

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

D E

C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

AHU-202

20,000 CFM

MAX SA

7470 CFM SA

TO A1

M-233

TO D1

M-235

SA

VAV-702

35 CFM

2160 CFM

6920 CFM 315 CFM

AOC OPS FLOOR

5040 CFM

200 CFM

ELECT. RM.

200 CFM

115 CFM

COPY

115 CFM

50 CFM

50 CFM

RADIO ROOM

4500 CFM OA

L-9 CD-07

5040 CFM RA

15,500 CFM

MAX RA

FROM A1

M-233

EF-203

FROM C1

M-234

EA

3900 CFM EA

(600 CFM PRESSURIZATION)

A

B

C

E

VAV-724

VAV-725

SA

RA

CD-19

CD-28

VAV-726

VAV-727

FROM D1

M-235

D

RA

FROM E1

M-233

950 CFM

950 CFM

CONTING. RC

VAV-713 VAV-711

115 CFM

115 CFM

ITAMS STORAGE

VAV-712

210 CFM

210 CFM

AOC OPS BRK. RM.

VAV-709

30 CFM

HALL

30 CFM

370 CFM

370 CFM

AOC BRK. RM.

VAV-710 VAV-708

TO C1

M-234

FROM C1

M-234

TO E1

M-233

RA

60 CFM

60 CFM

WXD OFF.

VAV-728

60 CFM

80 CFM

WXD OFF.

20 CFM

TO C1

M-234

TA

60 CFM

60 CFM

ALDPA DIV. CHF

200 CFM

200 CFM

ALDPA OFF.

60 CFM

60 CFM

WXD DD OFF.

60 CFM

60 CFM

WXD DIR. OFF.

B

C

F

G

H

SA SA

RA

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O J E

C T

N O

K

R S

M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

J O

IN

T

O P

E R

A T

IO

N

S

M

IS

S

IO

N P

L A

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

/1

/2

V D

Y D

M-233

C D

A Z

E

G F

A U

S T

A A

L D

A N

A

O C

T O

B E

R

M

-2 .D

W G

A

IR

F L O

W D

IA

G

R A

M S

A

H U

-2

SCALE:NTSE1

AIRFLOW DIAGRAM - AHU-202 (1/5)

SCALE:NTSA1

AIRFLOW DIAGRAM - AHU-202 (2/5)

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

2. AHU AIRFLOWS SHOWN ARE COOLING

BLOCK LOAD. ROOM AIRFLOWS SHOWN ARE

COOLING PEAK LOAD.

3. FPVAV AIRFLOWS ARE COOLING PEAK

AIRFLOWS.

4. UNCONNECTED ROOM AIRFLOWS ARE

PRESSURIZATION AIR.

SUPPLY AIR (SA)

RETURN AIR (RA)

EXHAUST / TRANSFER AIR (EA / TA)

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C

E R

T

IF

IE

D

F

IN

A L

I S

S U

E D

F O

R B

ID

D

E C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

FROM A1

M-233

SA

VAV-707 VAV-722

VAV-706

40 CFM

60 CFM

20 CFM

MOD GS-15

VAV-705

TO A1

M-233

RA

40 CFM

60 CFM

20 CFM

MOD DIV. CHF.

VAV-704

40 CFM

60 CFM

20 CFM

GAD DIR. OFF.

40 CFM

60 CFM

20 CFM

MOD O-6

VAV-703

20 CFM

40 CFM

60 CFM

MOD DIV. CHF.

FPVAV-702

10 CFM

40 CFM

70 CFM

MOD DD OFF.

20 CFM

10 CFM

40 CFM

70 CFM

MOD DIV. CHF.

20 CFM

15 CFM

425 CFM

460 CFM

MOD DIR. OFF.

20 CFM

20 CFM

40 CFM

60 CFM

MOD DIV. CHF.

20 CFM

100 CFM

120 CFM

MOD SECT. OFF.

40 CFM

60 CFM

20 CFM

GAD DD OFF.

40 CFM

60 CFM

20 CFM

GAD EXEC. OFF.

40 CFM

60 CFM

20 CFM

AAD EXEC. OFF.

40 CFM

60 CFM

20 CFM

AAD DD OFF.

40 CFM

60 CFM

20 CFM

MOD. DIV. CHF.

40 CFM

60 CFM

20 CFM

MOD. DIV. CHF.

50 CFM

70 CFM

20 CFM

AAD DIR. OFF.

280 CFM

HALL

280 CFM

F

VAV-723

FPVAV-704

VAV-721

FPVAV-705

FPVAV-706

310 CFM

2400 CFM

3750 CFM

1430 CFM

OPEN OFFICE

200 CFM

TO D1

M-233

H

E

FROM A1

M-233

TA

G

EA

TO VAV-722

TO FPVAV-705 & FPVAV-706 TO VAV-723 TO FPVAV-704

L

Q N P

L

N

P

Q

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A T

E

IS

S

U E

D A

T E

P R

O

JE

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

LI

C

IT

A

T

IO

N N

O

U .S

. A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

LE

K

E N

T U

C K

Y

W A

R D

P A

R K

W A

Y

K A

N S

A S

C

IT

Y

M O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O

JE

C T

N O

. K R

S M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

JO

IN

T O

P E

R A

T

IO

N S

M

IS

S

IO

N

P

LA

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

2/

/2

V D

Y D

M-234

C . D

A Z

E

G . F

A U

S T

A . A

LD

A

N A

O C

T O

B E

R

M

-2

.D W

G A

IR

F

L O

W D

IA

G

R A

M S

A

H U

-2

SCALE:NTSC1 AIRFLOW DIAGRAM - AHU-202 (3/5)

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

2. AHU AIRFLOWS SHOWN ARE COOLING

BLOCK LOAD. ROOM AIRFLOWS SHOWN ARE

COOLING PEAK LOAD.

3. FPVAV AIRFLOWS ARE COOLING PEAK

AIRFLOWS.

4. UNCONNECTED ROOM AIRFLOWS ARE

PRESSURIZATION AIR.

SUPPLY AIR (SA)

RETURN AIR (RA)

EXHAUST / TRANSFER AIR (EA / TA)

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

D E

C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

M-233

100 CFM

100 CFM

COLLATERAL

SERVER ROOM

VAV-714 VAV-715

20 CFM

1960 CFM

1980 CFM

ALDS

30 CFM

VEST.

VAV-717

10 CFM

260 CFM

270 CFM

CONF. RM.

VAV-718

TO A1

M-235

SA

FROM A1

M-235

RA

TO D1

M-233

RA

100 CFM

100 CFM

MAINT. LAB

45 CFM

35 CFM

HALL

570 CFM

570 CFM

HELP DESK

290 CFM

260 CFM

ALDL

40 CFM

1800 CFM

1840 CFM

ISRD / SRDI/

A3DI / SRDP

35 CFM

35 CFM

HALL

SA

J

K

A

D

FPVAV-707

VAV-716

VAV-731

FPVAV-703

VAV-719

VAV-720

FROM D1

M-235

VAV-701

10 CFM

160 CFM

170 CFM

ISRD DIR. OFF.

FPVAV-701

10 CFM

370 CFM

380 CFM

CONF. RM.

VAV-729

TO D1

M-235

RA

10 CFM

115 CFM

125 CFM

ISRD DD OFF.

40 CFM

40 CFM

HALL

10 CFM

220 CFM

230 CFM

JWICS CAFE

VAV-730

70 CFM

COFFEE

70 CFM

50 CFM

50 CFM

SECURE

TELECOMM ROOM

70 CFM

140 CFM

70 CFM

HALL

200 CFM

JWICS CONF. RM

200 CFM

30 CFM

30 CFM

VEST.

J

K

SA

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A T

E

IS

S

U E

D A

T E

P R

O

JE

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

LI

C

IT

A

T

IO

N N

O

U .S

. A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

LE

K

E N

T U

C K

Y

W A

R D

P A

R K

W A

Y

K A

N S

A S

C

IT

Y

M O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O

JE

C T

N O

. K R

S M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

JO

IN

T O

P E

R A

T

IO

N S

M

IS

S

IO

N

P

LA

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

2/

/2

V D

Y D

M-235

C . D

A Z

E

G . F

A U

S T

A . A

LD

A

N A

O C

T O

B E

R

M

-2

.D W

G A

IR

F

L O

W D

IA

G

R A

M S

A

H U

-2

SCALE:NTSD1 AIRFLOW DIAGRAM - AHU-202 (4/5)

SCALE:NTSA1 AIRFLOW DIAGRAM - AHU-202 (5/5)

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

2. AHU AIRFLOWS SHOWN ARE COOLING

BLOCK LOAD. ROOM AIRFLOWS SHOWN ARE

COOLING PEAK LOAD.

3. FPVAV AIRFLOWS ARE COOLING PEAK

AIRFLOWS.

4. UNCONNECTED ROOM AIRFLOWS ARE

PRESSURIZATION AIR.

SUPPLY AIR (SA)

RETURN AIR (RA)

EXHAUST / TRANSFER AIR (EA / TA)

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

D E

C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

GROUND FLOOR

100' - 0"

GROUND FLOOR CEILING

118' - 0"

SECOND FLOOR CEILING

136' - 0"

DEF

260-12"ø

SA-Q

260-12"ø

SA-Q

10"ø SA

12"ø SA 14"ø SA

VAV-105

3/4" HWR

3/4" HWS

12"ø SA

12"ø SA

385-12"x12"

RA-K

8"x12" RA

14"ø SA

16"x16" EA

EF-108

12"ø SA

3/4" HWR

3/4" HWS

16"x16" RA

14"x16" SA

5"ø SA

1 1/4" HWS

1 1/4" HWR

DS-105

FPVAV-101

8"ø SA

GROUND FLOOR

100' - 0"

GROUND FLOOR CEILING

118' - 0"

AHU-101

24"x70" OA

28"x70" RA

34"x32" RA

30"ø SA

32"x34" RA

3" CHWS

3" CHWR

UH-105

3/4" HWR

3/4" HWS

3/4" HWS

3/4" HWR

20"x20" EA

EQUIPMENT

PAD

3/4" HWR

3/4" HWS 1" HWR

1" HWS

M

24"x24" OA

1 1

DS-102

3/4" COND

1 1/2" HWR

32"x34" RA

3/4" COND

30"ø SA

CD-30

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A T

E

IS

S

U E

D A

T E

P R

O

JE

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

LI

C

IT

A

T

IO

N N

O

U .S

. A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

LE

K

E N

T U

C K

Y

W A

R D

P A

R K

W A

Y

K A

N S

A S

C

IT

Y

M O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O

JE

C T

N O

. K R

S M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

JO

IN

T O

P E

R A

T

IO

N S

M

IS

S

IO

N

P

LA

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

2/

/2

V D

Y D

M-301

C . D

A Z

E

G . F

A U

S T

N . N

IE

M

A N

N

O C

T O

B E

R

M

-3

.D W

G M

E C

H A

N

IC

A L S

E C

T

IO

N S

SCALE: 1/4" = 1'-0"C1 MECHANICAL SECTION - ROOM 1061 & 1056

SCALE: 1/4" = 1'-0"A1 MECHANICAL SECTION - AHU-01 - ROOM 1109

0 2' 4' 8'

0 2' 4' 8'

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

KEYED NOTES:

SEE DETAIL A1 ON SHEET M-510.1

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

D E

C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

GROUND FLOOR CEILING

118' - 0"

QR

AHU-105

28"x28" SA

32"x44" RA

32"x44" RA

EF-109

1" HWS

1" HWR

3/4" HWR

3/4" HWS

28"x60" OA

L-08

1" HWR

1" HWS

36"x12" EA

3" CHWS

EQUIPMENT

PAD

2 1/2" CHWR

1" COND TO

FD-A

2 1/2" CHWS

2 1/2" CHWR

3" CHWR

3" CHWS

M

M

CD-05

CD-34

GROUND FLOOR CEILING

118' - 0"

Q R

AHU-104

2" CHWS

2" CHWR

15"x23" OA

M

1" HWR

1" HWS

3/4" HWR

3/4" HWS

UH-104

22"x82" OA

18"x56" OA

20"x32" RA

L-08

M

EQUIPMENT

PAD

1" COND

1" COND TO FD-A

28"x20" SA

MCD-33

CD-04

CD-22

1" HWS

1" HWR

GROUND FLOOR

100' - 0"

GROUND FLOOR CEILING

118' - 0"

12 13

CH-102

EF-101

6" CHWR

6" CHWR

6" CWR

UH-101

EF-103 30"x24" EA 33"x33" EA

24"x24" EA

16"x36" EA L-05

AS-01

6" CHWR

6" CHWS

3" RS

8"ø FLUE 4"ø FLUE

3/4" HWS

3/4" HWR

3" RS

EQUIPMENT

PAD

6" CHWS/R 8

M CD-12

EF-102

20"x22" EA

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A T

E

IS

S

U E

D A

T E

P R

O

JE

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

LI

C

IT

A

T

IO

N N

O

U .S

. A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

LE

K

E N

T U

C K

Y

W A

R D

P A

R K

W A

Y

K A

N S

A S

C

IT

Y

M O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O

JE

C T

N O

. K R

S M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

JO

IN

T O

P E

R A

T

IO

N S

M

IS

S

IO

N

P

LA

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

2/

/2

V D

Y D

M-302

C . D

A Z

E

G . F

A U

S T

N . N

IE

M

A N

N

O C

T O

B E

R

M

-3

.D W

G M

E C

H A

N

IC

A L S

E C

T

IO

N S

SCALE: 1/4" = 1'-0"E5 MECHANICAL SECTION - AHU-105 - ROOM 1174

SCALE: 1/4" = 1'-0"E1 MECHANICAL SECTION - AHU-104 - ROOM 1174

0 2' 4' 8'0 2' 4' 8'

SCALE: 1/4" = 1'-0"A1 MECHANICAL SECTION - CH-102 - ROOM 1011

0 2' 4' 8'

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

KEYED NOTES:

FILTER BOX FB-104 TO BE INSTALLED

UPSTREAM OF AIRFLOW MEASUREMENT

STATION. REFER TO FILTER BOX SCHEDULE

ON SHEET M-611.

FILTER BOX FB-105 TO BE INSTALLED

UPSTREAM OF AIRFLOW MEASUREMENT

STATION. REFER TO FILTER BOX SCHEDULE

ON SHEET M-611.

AIR FLOW MEASUREMENT STATION.

SECURE PERIMETER PENETRATION. SEE

DETAIL A1 ON SHEET M-510.

SEE DETAIL A1 ON SHEET M-510.

48"x12" EA DOWN. TERMINATE DUCT WITHIN

12" OF FINISHED FLOOR. PROVIDE 1/2" BIRD

SCREEN COVER.

TERMPORARY CHILLER CONNECTION.

PROVIDE SEALED BLIND FLANGE. PRIME AND

PAINT ALL EXPOSED PIPE. COVER WITH

REMOVEABLE WEATHER PROOF INSULATION

BLANKET. LABEL SUPPLY AND RETURN

CONNECTIONS ON INSIDE OF BUILDING.

TEMPORARY CHILLER CONNECTION PIPES.

INSULATE FULLY AND SLOPE TOWARDS

OUTLET.

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

D E

C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

SECOND FLOOR CEILING

136' - 0"

7 8 9

46"x46" RA

14"x18" EA

1" CHWS

1" CHWR

2" HWR

2" HWS

30"x30" OA

20"x20" RA 26"x26" OA

30"x30" OA

12"x12"

TA-D

2" HWR

2" HWS

3/4" HWR

3/4" HWS

4" CHWS

1" CHWS

4" CHWR

2" HWS

2" HWR

3/4" HWS

3/4" HWR

3/4" HWR

3/4" HWS

34"x34" RA

36"x36" RA

34"x34" RA

1 1/2" HWR

1" CHWR

1 1/2" HWS

24"x24" RA

4" CHWR

3/4" HWR

3/4" HWS

38"ø SA

GROUND FLOOR CEILING

118' - 0"

SECOND FLOOR CEILING

136' - 0"

J H

AHU-202

46"x46" RA

46"x46" RA

2 1/2" CHWS

34"x34" RA

6" CHWS

6" CHWR

(2)175-12"x6"

EA-K

38"ø SA12"x12" TA

(2)12"x12"

TA-E

2" HWS

2" HWR

20"x24" OA

28"x108" OA

M

M

4" CHWR

4" CHWS

3" CHWR

EQUIPMENT

PAD

3" CHWS

2 1/2" CHWR

26"x26" OA3

18"x14" EA

1 1/4" COND

1" CHWR

1" CHWS

CD-07

CD-19

GROUND FLOOR CEILING

118' - 0"

SECOND FLOOR CEILING

136' - 0"

9 10

1 1/2" HWR

1 1/2" HWS

8"ø SA

16"x22" SAVAV-725

14"ø SA18"ø SA

865-24"x12"

SA-L

22"x16" SA

1 1/2" HWS

1 1/2" HWR

3/4" HWS

3/4" HWR

4" CHWS

4" CHWR3/4" HWR

3/4" HWS

1" CHWS

2" CHWS

2" CHWR

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A T

E

IS

S

U E

D A

T E

P R

O

JE

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

LI

C

IT

A

T

IO

N N

O

U .S

. A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

LE

K

E N

T U

C K

Y

W A

R D

P A

R K

W A

Y

K A

N S

A S

C

IT

Y

M O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O

JE

C T

N O

. K R

S M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

JO

IN

T O

P E

R A

T

IO

N S

M

IS

S

IO

N

P

LA

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

2/

/2

V D

Y D

M-303

C . D

A Z

E

G . F

A U

S T

N . N

IE

M

A N

N

O C

T O

B E

R

M

-3

.D W

G M

E C

H A

N

IC

A L S

E C

T

IO

N S

SCALE: 1/4" = 1'-0"D1 MECHANICAL SECTION - LOOKING EAST

SCALE: 1/4" = 1'-0"B6 MECHANICAL SECTION - AHU-202 - ROOM 2092

0 2' 4' 8'

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

0 2' 4' 8'

KEYED NOTES:

FILTER BOX FB-202 TO BE INSTALLED

UPSTREAM OF AIRFLOW MEASUREMENT

STATION. REFER TO FILTER BOX SCHEDULE

ON SHEET M-611.

AIRFLOW MEASUREMENT STATION.

PROVIDE A MINIMUM OF 10 FEET OF

ACOUSTICAL DUCT LINING PRIOR TO AHU

CONNECTION.

SCALE: 1/4" = 1'-0"A1 MECHANICAL SECTION - ROOM 2159

0 2' 4' 8'

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

D E

C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

SECOND FLOOR CEILING

136' - 0"

JH

AHU-201

40"ø SA

40"ø SA

26"x26" OA

34"x108" RA

3" HWS

3" HWR

3" CHWS

175-12"x6"

EA-K

M

34"x108" OA

2" HWS

2" HWR

30"x30" OA 20"x20" OA

2" HWS

2" HWR

3" CHWR

2" HWR

2" HWS

3/4" HWS

24"x24" OA

18"x14" EA

3/4" HWR

36"x36" RA

3/4" COND

34"x34" RA

34"x36" RA

3/4" COND

EQUIPMENT PAD

2" HWS

2" HWR

30"x30" OA

M

CD-06

CD-35

GROUND FLOOR CEILING

118' - 0"

8 9

32"x20" RA 18"x20" OA

AHU-104 AHU-105

18"x20" OA

44"x32" RA

3/4" HWS

3/4" HWR

3/4" HWS

3/4" HWR

40"x22" OA

152"x22"

OA

M M

32"x20" RA

M

24"x14" OA M

12"x16" EA

EQUIPMENT

PAD (TYP)

M

CD-04

CD-33

CD-22

CD-05

CD-34

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A T

E

IS

S

U E

D A

T E

P R

O

JE

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

LI

C

IT

A

T

IO

N N

O

U .S

. A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

LE

K

E N

T U

C K

Y

W A

R D

P A

R K

W A

Y

K A

N S

A S

C

IT

Y

M O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O

JE

C T

N O

. K R

S M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

JO

IN

T O

P E

R A

T

IO

N S

M

IS

S

IO

N

P

LA

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

2/

/2

V D

Y D

M-304

C . D

A Z

E

G . F

A U

S T

N . N

IE

M

A N

N

O C

T O

B E

R

M

-3

.D W

G M

E C

H A

N

IC

A L S

E C

T

IO

N S

SCALE: 1/4" = 1'-0"D1 MECHANICAL SECTION - AHU-201 - ROOM 2092

0 2' 4' 8'

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

SCALE: 1/4" = 1'-0"D5 MECHANICAL SECTION - AHU-104 & 105

0 2' 4' 8'

KEYED NOTES:

FILTER BOX FB-201 TO BE INSTALLED

UPSTREAM OF AIRFLOW MEASUREMENT

STATION. REFER TO FILTER BOX SCHEDULE

ON SHEET M-611.

AIRFLOW MEASUREMENT STATION.

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

D E

C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

8 9

J

H

22"ø SA 24"ø SA

AHU-102

AHU-103

20"x24" OA20"x22" OA 24"x20" OA UP23"x15" OA UP

3" HWR UP 3" HWS UP

18"x18"

TA-J

2 1/2" CHWS

24"x24" RA

600-14"x14"

EA-K

M

M

7 6

1" HWS

1" HWR

2 1/2" CHWR

18"x18"

TA-D

1 1/2" HWR

1 1/2" HWS

2" CHWS

2" CHWR

6" CHWS

6" CHWR

6" CHWS 6" CHWR

1" HWR

1" HWS

3/4" COND

4" CHWS

4" CHWR

1" COND

30"x30" RA

1" COND

6" CHWR UP

6" CHWS UP

EQUIPMENT

PAD

CD-31

CD-32

CD-02

CD-03

M M

3/4" COND

J

A1

M-301

AHU-101

34"x32" RA

34"x32" RA

1L-07

M M

12"x24" OA

EF-106

24"x24" OA

UH-105

34"x32" RA

28"x28" OA DN

106"x24" OA

M

20"ø EA

L-07

DS-002

EQUIPMENT

PAD

CD-01

CD-30

CD-21CD-20

M

J

A1

M-301

AHU-101

EF-106

UH-105

1" HWR

1" HWS 3/4" HWS

3/4" HWR

3/4" HWS

3/4" HWR

3" CHWS DN

3" CHWR DN

EQUIPMENT PAD

3" CHWS

3" CHWR

3/4" COND

3/4" COND DN

3/4" COND

1 1/2" HWS

1 1/2" HWR

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O J E

C T

N O

K

R S

M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

J O

IN

T

O P

E R

A T

IO

N

S

M

IS

S

IO

N P

L A

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

/1

/2

V D

Y D

M-401

C D

A Z

E

G F

A U

S T

N N

IE

M

A N

N

O C

T O

B E

R

M

-4 .D

W G

H V

A C

E N

L A

R G

E D

P L A

N

M E

C H

R O

O M

S

SCALE: 1/4" = 1'-0"D3

MECHANICAL ENLARGED PLAN - MECH ROOM 1064

SCALE: 1/4" = 1'-0"A1

HVAC ENLARGED PLAN - MECH ROOM 1109

N

0 2' 4' 8'

N

0 2' 4' 8'

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

KEYED NOTES:

CONTRACTOR TO PROVIDE SHEETMETAL

DIVIDERS TO DIVIDE LOUVER PLENUM INTO

SECTIONS. SEE DETAIL.

AIRFLOW MEASUREMENT STATION.

FILTER BOX FB-101 TO BE INSTALLED

UPSTREAM OF THE AIR FLOW

MEASUREMENT STATION ON VERTICAL

DOWNWARD DUCT. REFER TO FILTER BOX

SCHEDULE ON SHEET M-611.

FILTER BOX FB-102 TO BE INSTALLED

UPSTREAM OF AIR FLOW MEASUREMENT

STATION ON VERTICAL DOWNWARD DUCT,

DOWNSTREAM OF THE CONTROL DAMPER.

REFER TO FILTER BOX SCHEDULE ON SHEET

M-611.

FILTER BOX FB-103 TO BE INSTALLED

UPSTREAM OF AIR FLOW MEASUREMENT

DEVICE, DOWNSTREAM OF CONTROL

DAMPER. REFER TO FILTER BOX SCHEDULE

ON SHEET M-611.

PROVIDE A MINIMUM OF 5 FEET OF

ACOUSTICAL DUCT LINING PRIOR TO AHU

CONNECTION.

PROVIDE A MINIMUM OF 10 FEET OF

ACOUSTICAL DUCT LINING PRIOR TO AHU

CONNECTION.

SEE DETAIL A1 ON SHEET M-510.

PROVIDE 1/2" BIRD SCREEN COVER.

SCALE: 1/4" = 1'-0"A6

MECHANICAL PIPING ENLARGED PLAN - MECH ROOM 1109 N

0 2' 4' 8'

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C

E R

T

IF

IE

D

F

IN

A L

I S

S U

E D

F O

R B

ID

D

E C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

8 9

Q

R

AHU-104 AHU-105

M

M

M

L-08 1

240"x22" OA

EF-109

28"x20" SA

E5

M-302

E1

M-302

UH-104

44"x32" RA

82"x22" OA

12"x16" EA

D5

M-304

M

L-08

12"x36" EA

5 EQUIPMENT

PAD (TYP)

28"x28" SA

CD-22

CD-05

CD-04

CD-34

CD-33

CD-23

MM

32"x20" RA

8 9

Q

R

E5

M-302

E1

M-302

1" HWS

1" HWR

3/4" HWS

3/4" HWRUH-104

AHU-104

AHU-105

EF-109

3/4" HWR

3/4" HWS

1" HWR

1" HWS

2 1/2" CHWR

2 1/2" CHWS

D5

M-304

3" CHWR DN

3" CHWS DN

1 1/2" HWR DN

1 1/2" HWS DN

1" COND

1" COND

3/4" COND DN

8 9

J

H

D1

M-303

B6

M-303

D1

M-304

2092AHU-201 AHU-202

2" HWR

2" HWS

3" CHWS

3" CHWR

3" CHWS

2" HWR

2" HWS

2" HWR

2" HWS

3" CHWR

6" CHWR DN

6" CHWS DN

1" CHWS

1" CHWR

1 1/2" COND

TO FD-A 1 1/4" COND TO FD-A

3/4" COND

2" HWR DN

2" HWS DN

EQUIPMENT

PAD (TYP)

4" CHWS DN

4" CHWR DN

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O J E

C T

N O

K

R S

M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

J O

IN

T

O P

E R

A T

IO

N

S

M

IS

S

IO

N P

L A

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

/1

/2

V D

Y D

M-402

C D

A Z

E

G F

A U

S T

N N

IE

M

A N

N

O C

T O

B E

R

M

-4 .D

W G

H V

A C

E N

L A

R G

E D

P L A

N

M E

C H

R O

O M

S

SCALE: 1/4" = 1'-0"D1

HVAC ENLARGED PLAN - MECH ROOM 1174

N

0 2' 4' 8'

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

KEYED NOTES:

CONTRACTOR TO PROVIDE SHEETMETAL

DIVIDERS TO DIVIDE LOUVER PLENUM INTO

SECTIONS. SEE DETAIL.

FILTER BOX AND AIRFLOW MEASUREMENT

STATION ON VERTICAL DUCT. SEE SECTION

E5 ON SHEET M-302

PROVIDE A MINIMUM OF 5 FEET OF

ACOUSTICAL DUCT LINING PRIOR TO AHU

CONNECTION.

SECURE PERIMETER PENETRATION. SEE

DETAIL A1 ON SHEET M-510.

PROVIDE 1/2" BIRD SCREEN COVER.

SCALE: 1/4" = 1'-0"D5

MECHANICAL PIPING ENLARGED PLAN - ROOM 1174

N

0 2' 4' 8'

SCALE: 1/4" = 1'-0"A3

MECHANICAL PIPING ENLARGED PLAN - ROOM 2092

N

0 2' 4' 8'

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C

E R

T

IF

IE

D

F

IN

A L

I S

S U

E D

F O

R B

ID

D

E C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

7 8 9

L

H

D1

M-303

AHU-202AHU-201 36"x36" RA

23"x27" OA UP35"x27" OA UP

M

M

M

B6

M-303 D1

M-304

12"x12" TA

12"x12"

TA-D

34"x34" RA 34"x34" RA

14"x14" SA

VAV-713

26"x26" RA

22"x22" RA

24"ø SA

12"x8" SA 5"ø SA8"ø SA VAV-711

60-8"ø

SA-B

60-8"ø

SA-B

310-8"ø

SA-A

115-8"x8"

RA-F

VAV-712

115-6"ø

SA-A

5"ø SA

370-12"x12"

RA-D

18"x14" EA

18"x14" EA

12"x12" EA

550-16"x16"

EA-D

10"ø SA

8"ø SA

14"x12" SA

26"x26" RA30"x30" RA

16"x16" RA

950-22"x22"

RA-D

350-12"x12"

EA-D

16"x16"

TA-D

10"x10" EA

125-6"x6"

EA-F

60-6"x6" EA-F550-16"x16"

EA-D

12"x12" EA

14"x14" EA

18"x18"

TA-D

8"ø SA

350-10"x10"

EA-D

150-8"ø

SA-A

6"x6" EA

VAV-71410"ø SA

60-6"x6"

RA-F

60-6"x6"

RA-F

1 1

1 1

1 1 1

18"x18" TA

18"x18"

TA-E

12"x12"

TA-G

12"x12"

TA-F

8"x8" TA

22"x10" TA

22"x10"

TA-H

10"x10" EA UP 1

18"x18"

TA-D

18"x18"

TA-E

20"x20" RA UP

24"x24" RA

24"ø SA UP

10"ø SA UP

5"ø SA UP 1

5"ø SA UP 1

26"x26" RA UP 30"x30" RA UP

10"ø SA UP

18"x18" RA UP

10"x10" EA UP

18"x14" EA UP

20"x20" OA DN/UP 20"x24" OA DN 20"x24" OA UP 1

46"x46" RA UP

38"ø SA UP40"ø SA UP

18"x14" EA UP

6"x6" EA

10"x10" EA

10"x10" EA

CD-35

CD-19

CD-07CD-06

M

M

190-8"ø

SA-A

320-8"ø

SA-A

320-8"ø

SA-A

14"x14"

RA-K

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P

LO

T S

C A

LE

P

LO

T D

A T

E

IS

S

U E

D A

T E

P R

O

JE

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

LI

C

IT

A

T

IO

N N

O

U .S

. A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

LE

K

E N

T U

C K

Y

W A

R D

P A

R K

W A

Y

K A

N S

A S

C

IT

Y

M O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O

JE

C T

N O

. K R

S M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

JO

IN

T O

P E

R A

T

IO

N S

M

IS

S

IO

N

P

LA

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

2/

/2

V D

Y D

M-403

C . D

A Z

E

G . F

A U

S T

N . N

IE

M

A N

N

O C

T O

B E

R

M

-4

.D W

G H

V A

C E

N L A

R G

E D

P L A

N

A R

E A

C

SCALE: 1/4" = 1'-0"A1 SECOND FLOOR ENLARGED HVAC PLAN

GENERAL NOTES:

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND, SYMBOLS & ABBREVIATIONS.

2. SEE SHEET M-003 FOR ROOM NAMES.

3. RETURN AIR FROM AHU'S WILL BE DUCTED

TO ALL SPACES SERVED BY AHU.

4. SEE HVAC PIPING PLANS FOR THERMOSTAT

AND SWITCH LOCATIONS.

KEYED NOTES:

SEE ENLARGED PLAN A1 ON SHEET M-404

FOR CONTINUATION.

PROVIDE A MINIMUM OF 5 FEET OF

ACOUSTICAL DUCT LINING PRIOR TO AHU

CONNECTION.

PROVIDE A MINIMUM OF 10 FEET OF

ACOUSTICAL DUCT LINING PRIOR TO AHU

CONNECTION.

N 0 2' 4' 8'

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

D E

C

12 / 11 / 2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(2 of 3)

-0

7 8 9

L

H

D1

M-303

B6

M-303 D1

M-304

26"x26" OA

30"x30" OA

40"ø SA

23' - 9" BOD EL

18"x14" EA

18' - 3" BOD EL

20"x20" OA

26"x26" OA

26"x26" RA DN

20"x20" RA

20' - 9" BOD EL

30"x30" OA

20"x20" OA DN26"x26" OA DN

30"x30" OA

(2)175-12"x6"

EA-K

46"x46" RA

24' - 4" BOD EL

DS-022

38"ø SA

22"x22" OA DN

24"ø SA 24"ø SA

22"ø SA32"x32" RA

18"x18" RA

20' - 6" BOD EL

26"x26" OA

19' - 10" BOD EL

30"x30" RA DN

18"x14" EA DN 18"x14" EA DN

38"Ø SA DN

TO AHU-202

40"Ø SA DN

TO AHU-201

46"x46" RA DN

TO AHU-202

20"x20" RA DN

5"ø SA DN

5"ø SA DN

10"ø SA DN

24"ø SA

18"x18" RA DN

1 1

L-09

L-09

DS-021

20"x24" OA…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .