W912QR20R0004_Plans_Vol_III_(1of3)-0000.pdf

PDF 21 MB Posted

Attached to
Joint Operations Mission and Planning Center (JOMPC), Scott AFB
Solicitation number
W912QR20R0004
Issued by

About this file

This document provides details on a federal solicitation for the Joint Operations Mission and Planning Center (JOMPC) at Scott Air Force Base. The solicitation number is W912QR20R0004 and is being issued by the Department of the Army Corps of Engineers Engineering District Louisville. Interested parties should review the attached solicitation document and previously posted pre-solicitation notice for requirements regarding the JOMPC project. The solicitation seeks to procure planning and construction services for the JOMPC and includes relevant details on response dates, award timing, and the federal agency overseeing the opportunity.

View the file

Other files

File Type Posted
W912QR20R0004_Plans-0005.pdf PDF
W912QR20R0004_Specs-0005.pdf PDF
JA - SCO (Basis of Design) - JOMPC (Clean).pdf PDF
W912QR20R0004_SID-0004.pdf PDF
JA - District (Monaco - Brand Name)- JOMPC (Clean).pdf PDF
W912QR20R0004_SiteVisitRoster-0004.pdf PDF
JA - District (Water and Sewer Utilities) - JOMPC (Clean).pdf PDF
JA - SCO (HVAC Chillers - Brand Name) - JOMPC (Clean).pdf PDF
W912QR20R0004_Specs-0004.pdf PDF
JA - SCO (HVAC DDC - Brand Name) - JOMPC (Clean).pdf PDF
JA - District (Security Cameras - Brand Name) - JOMPC (Clean).pdf PDF
JA - District (Vindicator - Brand Name) - JOMPC (Clean).pdf PDF
W912QR20R0004_Plans-0004.pdf PDF
W912QR20R0004_Plans-0003.pdf PDF
W912QR20R0004_Specs_FFE-0003.pdf PDF
W912QR20R0004_Plans-0002.pdf PDF
W912QR20R0004_FFE-0002.pdf PDF
W912QR20R0004_Specs-0002.pdf PDF
W912QR20R0004_FFE-0001.pdf PDF
W912QR20R0004_Plans_Vol_II_(1of3)-0000.pdf PDF
W912QR20R0004_Plans_Vol_I_(3of3)-0000.pdf PDF
W912QR20R0004_SPECS_VOL_I-0000.pdf PDF
W912QR20R0004_Plans_Vol_II_(2of3)-0000.pdf PDF
W912QR20R0004_SID-0000.pdf PDF
W912QR20R0004_Plans_Vol_I_(2of3)-0000.pdf PDF
W912QR20R0004_Plans_Vol_IV-0000.pdf PDF
W912QR20R0004_Plans_Vol_III_(3of3)-0000.pdf PDF
W912QR20R0004_SPECS_VOL_IV-0000.pdf PDF
W912QR20R0004_FFE-0000.pdf PDF
W912QR20R0004_Plans_Vol_V_(1of2)-0000.pdf PDF
W912QR20R0004_Plans_Vol_I_(1of3)-0000.pdf PDF
W912QR20R0004_SPECS_VOL_III-0000.pdf PDF
W912QR20R0004_Plans_Vol_V_(2of2)-0000.pdf PDF
W912QR20R0004_Plans_Vol_II_(3of3)-0000.pdf PDF
W912QR20R0004_SPECS_VOL_II-0000.pdf PDF
W912QR20R0004_Plans_Vol_III_(2of3)-0000.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O J E

C T

N O

K

R S

M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

J O

IN

T

O P

E R

A T

IO

N

S

M

IS

S

IO

N P

L A

N N

IN

G

C E

N T

(J

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

/1

/2

V D

Y D

G-005-1

C L O

U D

O N

J B

R

IC

E

M A

R C

H

P ro je c t N u m b e rG

-0 -1

.D W

G C

O V

E R

V O

L U

M E

I

II

O

F

M A

R K

D E

S C

R

IP

T

IO

N D

A T

EUS Army Corps of Engineers ®

9400 WARD PARKWAY

KANSAS CITY, MO 64114

P2 NUMBER: 476084

JOINT OPERATIONS & MISSION PLANNING CENTER (JOMPC)

LOUISVILLE DISTRICT

SCOTT AIR FORCE BASE, ILLINOIS

PROJECT NUMBER: VDYD1055428

VOLUME III (1 OF 3)

ISSUED DATE: MARCH, 2021

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

08 March 2021

W912QR20R0004

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(1 of 3)

-0

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O J E

C T

N O

K

R S

M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

J O

IN

T

O P

E R

A T

IO

N

S

M

IS

S

IO

N P

L A

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

/1

/2

V D

Y D

G-006

C L O

U D

O N

J .B

R

IC

E

/1

/2

P ro je c t N u m b e rG

-0 .D

W G

S H

E E

T I

N D

E X

V

O L U

M E

I

II

FIRE PROTECTION SHEET LIST VOL III (1 OF 3)

FA001 FIRE ALARM NOTES, LEGEND AND ABBREVIATIONS

FA101 FIRST FLOOR FIRE ALARM PLAN - AREA A

FA102 FIRST FLOOR FIRE ALARM PLAN - AREA B

FA103 FIRST FLOOR FIRE ALARM PLAN - AREA C

FA104 FIRST FLOOR FIRE ALARM PLAN - AREA D

FA105 FIRST FLOOR FIRE ALARM PLAN - AREA E

FA106 FIRST FLOOR FIRE ALARM PLAN - AREA F

FA201 SECOND FLOOR FIRE ALARM PLAN - AREA A

FA202 SECOND FLOOR FIRE ALARM PLAN - AREA B

FA203 SECOND FLOOR FIRE ALARM PLAN - AREA C

FA204 SECOND FLOOR FIRE ALARM PLAN - AREA D

FA205 SECOND FLOOR FIRE ALARM PLAN - AREA E

FA206 SECOND FLOOR FIRE ALARM PLAN - AREA F

FA501 FIRE ALARM DETAILS

FA601 FIRE ALARM ONE-LINE DIAGRAM

FA602 FIRE ALARM MATRIX

FX001 FIRE SUPPRESSION NOTES, LEGEND AND ABBREVIATIONS

FX100 OVERALL FIRE SUPPRESSION FIRST FLOOR PLAN

FX101 FIRST FLOOR FIRE SUPPRESSION PLAN - AREA A

FX102 FIRST FLOOR FIRE SUPPRESSION PLAN - AREA B

FX103 FIRST FLOOR FIRE SUPPRESSION PLAN - AREA C

FX104 FIRST FLOOR FIRE SUPPRESSION PLAN - AREA D

FX105 FIRST FLOOR FIRE SUPPRESSION PLAN - AREA E

FX106 FIRST FLOOR FIRE SUPPRESSION PLAN - AREA F

FX200 OVERALL FIRE SUPPRESSION SECOND FLOOR PLAN

FX201 SECOND FLOOR FIRE SUPPRESSION PLAN - AREA A

FX202 SECOND FLOOR FIRE SUPPRESSION PLAN - AREA B

FX203 SECOND FLOOR FIRE SUPPRESSION PLAN - AREA C

FX204 SECOND FLOOR FIRE SUPPRESSION PLAN - AREA D

FX205 SECOND FLOOR FIRE SUPPRESSION PLAN - AREA E

FX206 SECOND FLOOR FIRE SUPPRESSION PLAN - AREA F

FX501 FIRE SUPPRESSION DETAILS AND RISER DIAGRAM

Grand total: 32

VOLUME III

GENERAL SHEET INDEX - VOUME III

SHEET NUMBER SHEET TITLE

G-005 COVER - VOLUME III

G-006 SHEET INDEX - VOLUME III

PLUMBING SHEET LIST VOL III (3 OF 3)

P-001 PLUMBING NOTES, LEGEND, SYMBOLS & ABBREVIATIONS

P-002 PLUMBING ROOM SCHEDULE

P-010 UNDER SLAB - OVERALL PLUMBING PLAN

P-011 UNDER SLAB PLUMBING PLAN - AREA A

P-012 UNDER SLAB PLUMBING PLAN - AREA B

P-013 UNDER SLAB PLUMBING PLAN - AREA C

P-014 UNDER SLAB PLUMBING PLAN - AREA D

P-015 UNDER SLAB PLUMBING PLAN - AREA E

P-016 UNDER SLAB PLUMBING PLAN - AREA F

P-017 UNDER SLAB PLUMBING PLAN - AREA H

P-100 FIRST FLOOR - OVERALL DOMESTIC WATER PLAN

P-101 FIRST FLOOR - DOMESTIC PLAN - AREA A

P-102 FIRST FLOOR - DOMESTIC PLAN - AREA B

P-103 FIRST FLOOR - DOMESTIC PLAN - AREA C

P-104 FIRST FLOOR - DOMESTIC PLAN - AREA D

P-105 FIRST FLOOR - DOMESTIC PLAN - AREA E

P-106 FIRST FLOOR - DOMESTIC PLAN - AREA F

P-107 FIRST FLOOR - DOMESTIC PLAN - AREA H

P-110 FIRST FLOOR - OVERALL WASTE & VENT PLAN

P-111 FIRST FLOOR - WASTE & VENT PLAN - AREA A

P-112 FIRST FLOOR - WASTE & VENT PLAN - AREA B

P-113 FIRST FLOOR - WASTE & VENT PLAN - AREA C

P-114 FIRST FLOOR - WASTE & VENT PLAN - AREA D

P-115 FIRST FLOOR - WASTE & VENT PLAN - AREA E

P-116 FIRST FLOOR - WASTE & VENT PLAN - AREA F

P-120 SECOND FLOOR - OVERALL DOMESTIC WATER PLAN

P-121 SECOND FLOOR - DOMESTIC PLAN - AREA A

P-122 SECOND FLOOR - DOMESTIC PLAN - AREA B

P-123 SECOND FLOOR - DOMESTIC PLAN - AREA C

P-124 SECOND FLOOR - DOMESTIC PLAN - AREA D

P-125 SECOND FLOOR - DOMESTIC PLAN - AREA E

P-126 SECOND FLOOR - DOMESTIC PLAN - AREA F

P-130 SECOND FLOOR - OVERALL WASTE & VENT PLAN

P-131 SECOND FLOOR - WASTE & VENT PLAN - AREA A

P-132 SECOND FLOOR - WASTE & VENT PLAN - AREA B

P-133 SECOND FLOOR - WASTE & VENT PLAN - AREA C

P-134 SECOND FLOOR - WASTE & VENT PLAN - AREA D

P-135 SECOND FLOOR - WASTE & VENT PLAN - AREA E

P-136 SECOND FLOOR - WASTE & VENT PLAN - AREA F

P-401 PLUMBING ENLARGED PLANS - UNDER SLAB

P-402 PLUMBING ENLARGED PLANS - UNDER SLAB

P-403 PLUMBING ENLARGED PLANS - FIRST FLOOR

P-404 PLUMBING ENLARGED PLANS - FIRST FLOOR

P-405 PLUMBING ENLARGED PLANS - FIRST FLOOR

P-406 PLUMBING ENLARGED PLANS - SECOND FLOOR

P-407 PLUMBING ENLARGED PLANS - SECOND FLOOR

P-501 PLUMBING DETAILS

P-502 PLUMBING DETAILS

P-503 PLUMBING DETAILS

P-504 PLUMBING DETAILS

P-505 PLUMBING DETAILS

P-601 PLUMBING SCHEDULES

P-602 PLUMBING SCHEDULES

P-901 PLUMBING WASTE AND VENT RISER

P-902 PLUMBING WASTE AND VENT RISER

P-903 PLUMBING WASTE AND VENT RISER

P-904 PLUMBING WASTE AND VENT RISER

P-905 PLUMBING DOMESTIC WATER RISER

P-906 PLUMBING DOMESTIC WATER RISER

P-907 PLUMBING DOMESTIC WATER RISER

P-908 PLUMBING DOMESTIC WATER RISER

P-909 PLUMBING RISER - STORM

Grand total: 62

CONTRACTORS ARE FREE TO USE ANY PRODUCT WHICH MEETS THE

GOVERNMENT'S MINIMUM REQUIREMENTS AND NOT IN CONFLICT WITH OTHER

CONTRACT PROVISIONS. UNLESS INDICATED OTHERWISE ON THE PLANS OR

SPECIFICATIONS (E.G. SOLE-SOURCE), ALL LISTED MANUFACTURERS ARE THE

BASIS OF DESIGN. FOR THESE BASIS OF DESIGN PRODUCTS, OTHER

MANUFACTURERS MAY BE SUBSTITUTED AS LONG AS THE STANDARD OF QUALITY

AND CHARACTERISTICS OF THE SUBSTITUTED MANUFACTURER MEET OR EXCEED

THE STANDARD OF QUALITY AND CHARACTERISTICS OF THE BASIS OF DESIGN.

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C

E R

T

IF

IE

D

F

IN

A L

I S

S U

E D

F O

R B

ID

D

E C

MECHANICAL SHEET LIST VOL III (1 OF 3)

M-001 MECHANICAL NOTES, LEGEND, SYMBOLS & ABBREVIATIONS

M-002 MECHANICAL NOTES

M-003 MECHANICAL ROOM SCHEDULE

M-100 FIRST FLOOR - OVERALL HVAC PLAN

M-101 FIRST FLOOR HVAC PLAN - AREA A

M-102 FIRST FLOOR HVAC PLAN - AREA B

M-103 FIRST FLOOR HVAC PLAN - AREA C

M-104 FIRST FLOOR HVAC PLAN - AREA D

M-105 FIRST FLOOR HVAC PLAN - AREA E

M-106 FIRST FLOOR HVAC PLAN - AREA F

M-107 FIRST FLOOR HVAC PLAN - AREA H

M-120 SECOND FLOOR - OVERALL HVAC PLAN

M-121 SECOND FLOOR HVAC PLAN - AREA A

M-122 SECOND FLOOR HVAC PLAN - AREA B

M-123 SECOND FLOOR HVAC PLAN - AREA C

M-124 SECOND FLOOR HVAC PLAN - AREA D

M-125 SECOND FLOOR HVAC PLAN - AREA E

M-126 SECOND FLOOR HVAC PLAN - AREA F

M-140 FIRST FLOOR - OVERALL MECHANICAL PIPING PLAN

M-141 FIRST FLOOR MECHANICAL PIPING PLAN - AREA A

M-142 FIRST FLOOR MECHANICAL PIPING PLAN - AREA B

M-143 FIRST FLOOR MECHANICAL PIPING PLAN - AREA C

M-144 FIRST FLOOR MECHANICAL PIPING PLAN - AREA D

M-145 FIRST FLOOR MECHANICAL PIPING PLAN - AREA E

M-146 FIRST FLOOR MECHANICAL PIPING PLAN - AREA F

M-147 FIRST FLOOR MECHANICAL PIPING PLAN - AREA H

M-160 SECOND FLOOR - OVERALL MECHANICAL PIPING PLAN

M-161 SECOND FLOOR MECHANICAL PIPING PLAN - AREA A

M-162 SECOND FLOOR MECHANICAL PIPING PLAN - AREA B

M-163 SECOND FLOOR MECHANICAL PIPING PLAN - AREA C

M-164 SECOND FLOOR MECHANICAL PIPING PLAN - AREA D

M-165 SECOND FLOOR MECHANICAL PIPING PLAN - AREA E

M-166 SECOND FLOOR MECHANICAL PIPING PLAN - AREA F

M-181 ROOF LEVEL - MECHANICAL PLAN - AREA A

M-182 ROOF LEVEL - MECHANICAL PLAN - AREA B

M-183 ROOF LEVEL - MECHANICAL PLAN - AREA D

M-184 ROOF LEVEL - MECHANICAL PLAN - AREA F

M-201 HEATING HOT WATER FLOW DIAGRAM

M-202 HEATING HOT WATER FLOW DIAGRAM

M-203 HEATING HOT WATER FLOW DIARGAM

M-204 HEATING HOT WATER FLOW DIAGRAM

M-205 HEATING HOT WATER FLOW DIAGRAM

M-206 HEATING HOT WATER FLOW DIAGRAM

M-207 HEATING HOT WATER FLOW DIAGRAM

M-211 CHILLED WATER FLOW DIAGRAM

M-212 CHILLED WATER FLOW DIAGRAM

Grand total: 46

MECHANICAL SHEET LIST VOL III (2 OF 3)

M-213 CONDENSER WATER FLOW DIAGRAM

M-220 AIRFLOW DIAGRAMS - AHU-101

M-221 AIRFLOW DIAGRAMS - AHU-101

M-222 AIRFLOW DIAGRAMS - AHU-102

M-223 AIRFLOW DIAGRAMS - AHU-102

M-224 AIRFLOW DIAGRAMS - AHU-103

M-225 AIRFLOW DIAGRAMS - AHU-103

M-226 AIRFLOW DIAGRAMS - AHU-104

M-227 AIRFLOW DIAGRAMS - AHU-105

M-228 AIRFLOW DIAGRAMS - AHU-105

M-229 AIRFLOW DIAGRAMS - AHU-105

M-230 AIRFLOW DIAGRAMS - AHU-201

M-231 AIRFLOW DIAGRAMS - AHU-201

M-232 AIRFLOW DIAGRAMS - AHU-201

M-233 AIRFLOW DIAGRAMS - AHU-202

M-234 AIRFLOW DIAGRAMS - AHU-202

M-235 AIRFLOW DIAGRAMS - AHU-202

M-301 MECHANICAL SECTIONS

M-302 MECHANICAL SECTIONS

M-303 MECHANICAL SECTIONS

M-304 MECHANICAL SECTIONS

M-401 HVAC ENLARGED PLAN - MECH ROOMS

M-402 HVAC ENLARGED PLAN - MECH ROOMS

M-403 HVAC ENLARGED PLAN - AREA C

M-404 HVAC ENLARGED PLAN - AREA C - 18' AFF

M-405 HVAC ENLARGED PLAN - MECH ROOMS

M-501 MECHANICAL DETAILS

M-502 MECHANICAL DETAILS

M-503 MECHANICAL DETAILS

M-504 MECHANICAL DETAILS

M-505 MECHANICAL DETAILS

M-506 MECHANICAL DETAILS

M-507 MECHANICAL DETAILS

M-508 MECHANICAL DETAILS

M-509 MECHANICAL DETAILS

M-510 MECHANICAL DETAILS

M-511 MECHANICAL DETAILS

M-512 MECHANICAL DETAILS

M-513 MECHANICAL DETAILS

M-601 MECHANICAL SCHEDULES

M-602 MECHANICAL SCHEDULES

M-603 MECHANICAL SCHEDULES

M-604 MECHANICAL SCHEDULES

M-605 MECHANICAL SCHEDULES

M-606 MECHANICAL SCHEDULES

M-607 MECHANICAL SCHEDULES

M-608 MECHANICAL SCHEDULES

M-609 MECHANICAL SCHEDULES

M-610 MECHANICAL SCHEDULES

M-611 MECHANICAL SCHEDULES

M-701 MECHANICAL CONTROLS - LEGEND

M-702 MECHANICAL CONTROLS - ARCHITECTURE & MISCELLANEOUS

M-703 MECHANICAL CONTROLS - CHILLED WATER PLANT

M-704 MECHANICAL CONTROLS - CHILLED WATER PLANT

M-705 MECHANICAL CONTROLS - CHILLED WATER PLANT

M-706 MECHANICAL CONTROLS - CHILLED WATER PLANT

M-707 MECHANICAL CONTROLS - CHILLED WATER PLANT

M-708 MECHANICAL CONTROLS - CHILLER ROOM EXHAUST FAN

M-709 MECHANICAL CONTROLS - HEATING HOT WATER

M-710 MECHANICAL CONTROLS - HEATING HOT WATER

M-711 MECHANICAL CONTROLS - VAV AHU

M-712 MECHANICAL CONTROLS - VAV AHU

M-713 MECHANICAL CONTROLS - VAV AHU

M-714 MECHANICAL CONTROLS - VAV TERMINAL UNIT

M-715 MECHANICAL CONTROLS - FAN POWERED VAV TERMINAL UNIT

M-716 MECHANICAL CONTROLS - COMPUTER ROOM AIR CONDITIONER - DOWNFLOW OR INROW

Grand total: 66

MECHANICAL SHEET LIST VOL III (3 OF 3)

M-717 MECHANICAL CONTROLS - COMPUTER ROOM AIR CONDITIONER - SUSPENDED

M-718 MECHANICAL CONTROLS - FAN COIL UNIT & UNIT HEATERS

M-719 MECHANICAL CONTROLS - EXHAUST FANS

M-720 MECHANICAL CONTROLS - LOADING DOCK HVAC

Grand total: 4

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(1 of 3)

-0

FIRE ALARM / MNS SYSTEM LEGEND GENERAL NOTES:AUDIBLE DESIGN CRITERIA:ABBREVIATIONS:

AFF ABOVE FINISHED FLOOR

ASD AIR SAMPLING DETECTOR

AWG AMERICAN WIRE GAGE

CD CANDELA

CIS COMMON INTELLIGIBILITY SCALE

CO CARBON MONOXIDE

DB DECIBEL

DBA DECIBEL A-WEIGHTED

DDC DIRECT DIGITAL CONTROL

EMCS ENERGY MONITORING AND CONTROL SYSTEM

FA FIRE ALARM

FDC FIRE DEPARTMENT CONNECTION

FM FM GLOBAL

FT FEET

IDC INITIATING DEVICE CIRCUIT

MNS MASS NOTIFICATION SYSTEM

NAC NOTIFICATION APPLIANCE CIRCUIT

NEC NATIONAL ELECTRICAL CODE

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION

RF RADIO FREQUENCY

SLC SIGNALING LINE CIRCUIT

SQ FT SQUARE FOOT

UL UNDERWRITERS LABORATORY

WP WEATHERPROOF (NEMA 250, TYPE 3R)

SECTION CUT SYMBOL

SECTION

LETTER

PLATE NUMBER

WHERE SECTION IS

DRAWN

VIEW

SECTION

P = PHOTOELECTRIC

S = SUPPLY

S P

SMOKE DETECTOR

S S

DUCT PHOTOELECTRIC SMOKE DETECTOR

WF WATER FLOW DETECTOR / SWITCH (PROVIDED BY DIVISION 21)

F MANUAL FIRE ALARM PULL STATION

LOC LOCAL OPERATING CONSOLE

FPC FIRE PUMP CONTROLLER (PROVIDED BY DIVISION 21)

VS VALVE SUPERVISORY SWITCH (PROVIDED BY DIVISION 21)

SS

SURGE SUPPRESSOR

(TRANSIENT VOLTAGE SURGE SUPPRESSOR)

AMP AMPLIFIER

ASD AIR SAMPLING DETECTOR

HORN / STROBE COMBINATION

S SPEAKER

STROBE

WALL MOUNT STROBE

AOM ADDRESSABLE OUTPUT CONTROL MODULE

AIM ADDRESSABLE INPUT MONITOR MODULE

ANTENNA

RL NON-ADDRESSABLE OUTPUT RELAY

REL ADDRESSABLE RELEASING MODULE

IM ISOLATION MODULE

BATT SECONDARY POWER SUPPLY (BATTERY)

GROUND

VISIBLE DESIGN CRITERIA:

ET EMERGENCY TEXTUAL VISIBLE DISPLAY

FACU/ACU

COMBINATION FIRE ALARM CONTROL UNIT

AND AUTONOMOUS CONTROL UNIT

ST SHUNT TRIP BREAKER (BY DIVISION 26)

ESR ELEVATOR SYSTEM RECALL PANEL (BY DIVISION 14)

NAC

NOTIFICATION CIRCUIT POWER BOOSTER,

EXTENDER PANEL

FAC FIRE ALARM COMMUNICATOR

1. PROVIDE AUDIBLE NOTIFICATION APPLIANCES AS INDICATED TO

ACCOMPLISH THE FOLLOWING DESIGN CRITERIA WITH ALL DOORS, FIRE

SHUTTERS, AND WINDOWS CLOSED. WHERE THIS DESIGN CRITERIA IS

NOT ACCOMPLISHED DURING ACCEPTANCE TESTING, PROVIDE ADDITIONAL

DEVICES TO MEET THE MINIMUM DESIGN CRITERIA WITHOUT EXCEEDING

THE LIMITATIONS OF THE FACU/ACU, NAC, OR AMP. (INCLUSIVE OF

PRESCRIBED SAFETY FACTORS).

2. PROVIDE A QUANTITY OF SPEAKERS IN EACH ROOM/AREA TO ACHIEVE THE

REQUIRED SOUND POWER AND INTELLIGIBILITY OUTLINED IN THESE

CONTRACT DOCUMENTS. NOTE: DEPENDING ON THE QUALITY OF SPEAKER

USED, SEVERAL SPEAKERS TAPPED AT A LOWER SETTING MAY BE

REQUIRED TO ACHIEVE THE PRESCRIPTIVE CIS SCORE.

3. PROVIDE A MINIMUM SOUND POWER OF 70 DBA AND 15 DBA OVER THE

AVERAGE AMBIENT SOUND LEVEL OR 5 DBA ABOVE THE MAXIMUM SOUND

LEVEL HAVING A DURATION OF AT LEAST 60 SECONDS, WHICHEVER IS

GREATER, AT THE MOST REMOTE LOCATION WITHIN THE ROOM/AREA

MEASURED AT 5 FT AFF. MEASURE THE SOUND POWER OFF THE

TEMPORAL THREE TONE PATTERN.

A. REDUCE THE SOUND POWER BY 6 DB EACH TIME THE DISTANCE

BETWEEN THE APPLIANCE AND THE LISTENER IS DOUBLED.

STARTING DISTANCE IS PER MANUFACTURER'S DATASHEET,

TYPICALLY 10 FT.

B. REDUCE THE SOUND POWER IN ACCORDANCE WITH THE

MANUFACTURER'S DATASHEET FOR SOUND POWER DISTRIBUTION

NOT PERPENDICULAR TO THE FACE OF THE APPLIANCE. REFER TO

MANUFACTURER'S TYPICAL SOUND OUTPUT DISTRIBUTION DIAGRAM.

C. IN LIEU OF THE MANUFACTURER'S PUBLISHED DB LOSS, ASSUME A

MINIMUM 15 DB LOSS THROUGH A STANDARD CLOSED DOOR.

4. MEET THE FOLLOWING INTELLIGIBILITY CRITERIA:

A. ACHIEVE A MINIMUM 0.80 CIS AT 5 FT AFF IN EACH ROOM OF THE

BUILDING, UNLESS OTHERWISE NOTED.

B. ROUNDING OF A CIS READING IS PERMITTED (E.G. 0.75 OR HIGHER

WOULD ROUND TO 0.8).

C. WHERE ROOMS HAVE EXCESSIVE SOUND REFLECTION FROM HARD

WALLS AND CEILINGS (SUCH AS METAL, TILE, CONCRETE), THE

OCCUPANT IS PERMITTED TO WALK UP TO 33 FT WITHIN THE SAME

ROOM TO REACH A LOCATION WHERE THE MINIMUM 0.80 CIS CAN BE

ACHIEVED. THIS AREA MUST BE READILY ACCESSIBLE, WITHOUT

REQUIRING THE OCCUPANT TO WALK THROUGH A SECURED

DOOR/AREA OR EXIT THE BUILDING.

D. IN NORMALLY UNOCCUPIED ROOMS SUCH AS MECHANICAL ROOMS,

ELECTRICAL ROOMS, COMMUNICATION ROOMS, STAIRWELLS, AND

STORAGE ROOMS THE OCCUPANT IS PERMITTED TO WALK UP TO 50

FT WITHIN THE SAME ROOM TO REACH A LOCATION WHERE THE

MINIMUM 0.80 CIS CAN BE ACHIEVED. THIS AREA MUST BE READILY

ACCESSIBLE, WITHOUT REQUIRING THE OCCUPANT TO WALK

THROUGH A SECURED DOOR/AREA OR EXIT THE BUILDING.

5. AVOID LOCATING SPEAKERS NEAR LOCS TO PREVENT SPEAKER FEEDBACK

AT THE LOC.

1. PROVIDE AN ADDRESSABLE COMBINED FIRE ALARM / MASS NOTIFICATION

SYSTEM.

2. COORDINATE ALL REQUIRED SYSTEMS TO THE SATISFACTION OF THE ENGINEER

AND AUTHORITY HAVING JURISDICTION. CORRECT ANY DEFICIENCIES,

INCONSISTENCIES, OR POORLY COORDINATED INSTALLATIONS AT NO ADDITIONAL

COST.

3. THE FIRE ALARM DRAWINGS ARE SCHEMATIC IN NATURE AND DO NOT SHOW A

FINAL QUANTITY OF DEVICES. DETERMINE THE FINAL QUANTITY AND LOCATION OF

ALL DEVICES IN ACCORDANCE WITH THE SPECIFICATIONS, CONTRACT DRAWINGS,

AND MANUFACTURER'S WRITTEN RECOMMENDATIONS TO BE COMPLIANT WITH

ALL APPLICABLE CODES AND STANDARDS. PROVIDE ADDITIONAL DEVICES WHEN

REQUIRED FOR A FULLY FUNCTIONING FIRE ALARM SYSTEM AS REQUIRED BY

NFPA 72, UFC 3-600-01, ICD/ICS 705, ETL 01-18 AND UFC 4-021-01.

4. ALL WIRING SHALL BE IN CONDUIT. CONCEAL ALL CONDUITS IN WALLS OR ABOVE

CEILINGS UNLESS OTHERWISE INDICATED. EXCEPTION: CONDUIT IS ALLOWED TO

BE SURFACE MOUNTED ON WALLS AND CEILINGS IN UNFINISHED AREAS (SUCH AS

MECHANICAL ROOM, ELECTRICAL ROOM, FIRE PROTECTION ROOM). CONDUIT

SHALL BE SURFACE MOUNTED INSIDE SECURE SPACES. WHERE A CONDUIT

SUPPLIES A DEVICE NOT MOUNTED DIRECTLY ON THE WALL OR CEILING, ROUTE

THE CONDUIT AS A SINGLE PENDENT DROP TO EACH DEVICE FROM THE CEILING

SURFACE ABOVE. DO NOT TRAPEZE CONDUIT ACROSS AN OPEN SPACE.

5. ALL FIRE ALARM JUNCTION BOXES, COVERS, COUPLINGS, AND CONDUITS IN

UNFINISHED AREAS ARE TO BE PROVIDED PRE-FINISHED RED FROM THE

FACTORY. PAINT EXPOSED CONDUIT AND JUNCTION BOXES IN FINISHED AREAS

TO MATCH ADJACENT SURFACES. JUNCTION BOXES' INSIDE COVERS SHALL BE

LABELED, "FIRE ALARM" AND THE CONDUIT SHALL HAVE PAINTED RED BANDS 3/4-

INCH WIDE AT 20 FT INTERVALS AND ON BOTH SIDES OF ALL FLOOR, WALL, AND

CEILING PENETRATIONS.

6. PROVIDE CONDUIT IN ACCORDANCE WITH THE REQUIREMENTS OF THE

ELECTRICAL SPECIFICATIONS, UNLESS OTHERWISE NOTED. SUPPORT CONDUIT IN

ACCORDANCE WITH THE NEC SUCH AS MAXIMUM 10 FT SUPPORT INTERVALS AND

3 FT FROM A TERMINATION. TENSION ONLY HANGERS (SUCH AS BATWINGS) ARE

NOT PERMITTED. FLEXIBLE CONDUIT IS ONLY PERMITTED WHEN CONNECTING TO

THE FOLLOWING DEVICES AND APPLIANCES: DEVICES LOCATED ON FIRE

SUPPRESSION EQUIPMENT SUCH AS FLOW SWITCHES AND TAMPER SWITCHES,

DEVICES AND APPLIANCES LOCATED IN REMOVABLE CEILING TILES, OR WHERE

SPECIFICALLY NOTED.

7. PROVIDE CONDUCTOR SIZING NOT LESS THAN 18 AWG FOR SLC. PROVIDE

CONDUCTOR SIZING NOT LESS THAN 16 AWG FOR NAC, SPEAKER CIRCUITS, AND

IDC, PER UFC 3-600-01. CONSISTENTLY COLOR COORDINATE ALL CONDUCTORS

THROUGH THE SYSTEM IN RELATION TO DEVICES THEY FEED SUCH AS SLC -

BLACK/RED, STROBE - YELLOW/BLUE. PROVIDE ADDRESSABLE SLC CIRCUITS

WITH SHIELDED CONDUCTORS, WHERE THE SHIELDING IS GROUNDED AT ONE

END. PROVIDE ALL CIRCUITS WITH LABELING AT THE POINT OF TERMINATION

SUCH AS SLC 1, NAC 8, IDC 4.

8. RUN CONDUCTORS FROM DEVICE TO DEVICE WITHOUT SPLICES. WIRE NUTS AND

CRIMP TYPE CONNECTORS ARE PROHIBITED. UTILIZE TERMINAL STRIPS WHERE

CONDUCTORS CANNOT BE DIRECTLY TERMINATED AT THE DEVICE SUCH AS

PIGTAILS OFF A HEAT DETECTOR.

9. DO NOT USE FIRE ALARM EQUIPMENT PANELS AS RACEWAY FOR ROUTING

POWER WIRING OR LOW VOLTAGE WIRING. ONLY ROUTE WIRING TERMINATING

WITHIN THE PANEL INTO THE PANEL. PROVIDE 1/4 INCH SEPARATION BETWEEN

POWER-LIMITED FIRE ALARM CIRCUITS AND POWER CIRCUITS.

10. MOUNTING DEVICES IN THE FACU/ACU, INCLUDING ANY SUBPANELS SUCH AS AMP,

NAC, AND FAC WHICH ARE NOT UL LISTED OR FM APPROVED AS PART OF THE

UNIT IS PROHIBITED.

11. PROVIDE SURGE SUPPRESSORS TO PROTECT ALL POWER SUPPLY CIRCUITS TO

THE FACU/ACU, INCLUDING ANY SUBPANELS SUCH AS AMP, NAC, FAC, AND ALL

FIRE ALARM CIRCUITS LEAVING OR ENTERING THE BUILDING. DEVICES AND

APPLIANCES MOUNTED DIRECTLY ON THE EXTERIOR OF THE BUILDING SUCH AS

WALL MOUNTED EXTERIOR SPEAKERS DO NOT REQUIRE SUPPRESSORS. MOUNT

SURGE SUPPRESSORS IN A SEPARATE ENCLOSURE, UNLESS IT IS UL LISTED OR

FM APPROVED AND INSTALLED IN THE CONTROL UNIT BY THE FACTORY.

12. INSTALL FIRE ALARM BATTERIES IN THE ENCLOSURE OF THE DEVICE/UNIT IT

SUPPORTS SUCH AS FACU/ACU ENCLOSURE OR IN AN INDEPENDENT DEDICATED

ENCLOSURE.

13. PROVIDE GAIN CONTROL ON ALL MICROPHONES.

14. ALL FIRE ALARM WORK IN RELATION TO THE SECURE SPACES SHALL BE IN

ACCORDANCE WITH ICD/ICS 705 V 1.5. REFERENCE SHEETS TY002 AND TY003 FOR

ADDITIONAL BOUNDARIES AND REQUIREMENTS FOR SECURE SPACES AND OPEN

STORAGE SPACES. GROUNDING OF PENETRATIONS SHALL BE IN ACCORDANCE

WITH DETAILS D1 AND D6/EG502.

15. IN-DUCT SMOKE DETECTORS ARE TO BE PROVIDED AT THE SPECIFIED

MECHANICAL EQUIPMENT AS LISTED ON SHEET FA601. REFERENCE MECHANICAL

DRAWING SCHEDULES AND PLANS FOR LOCATION AND QUANTITY OF

EQUIPMENT.

REMOTE ALARM INDICATOR

SECTION, DETAIL OR ELEVATION

IDENTIFICATION MARK

PLAN, SECTION, OR DETAIL TITLE

PLAN/SECTION/DETAIL TITLE

MNS PRIORITIZATION:

1. PROVIDE VISIBLE NOTIFICATION APPLIANCES AS REQUIRED TO ACHIEVE

THE COVERAGE INDICATED.

2. SPACE STROBES IN ACCORDANCE WITH THE CRITERIA OUTLINED IN NFPA

72, UNLESS OTHERWISE NOTED.

3. WHERE SPEAKERS AND STROBES ARE LOCATED IN THE SAME AREA, THEY

MAY BE COMBINED INTO ONE DEVICE.

1. MNS INPUTS TAKE PRIORITY OVER ALL OTHER INPUTS.

2. LOC INPUTS TAKE PRIORITY OVER BASE GENERATED INPUTS.

FAA FIRE ALARM ANNUNCIATOR

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O J E

C T

N O

K

R S

M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

J O

IN

T

O P

E R

A T

IO

N

S

M

IS

S

IO

N P

L A

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

/1

/2

V D

Y D

FA001

C K

N O

F F

A M

O O

R E

M D

A

IL

E Y

/1

/2

J O

M C

F A

.D

W G

F

IR

E A

L A

R M

N O

T E

S

L E

G E

N D

A N

D A

B B

R E

V

IA

T

IO

N S

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C

E R

T

IF

IE

D

F

IN

A L S

U B

M

IT

T A

L D

E C

12/11/2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(1 of 3)

-0

PROVIDE CEILING MOUNTED

SPEAKERS AND CLEAR STROBES AS

REQUIRED TO ACHIEVE DESIGN

CRITERIA.

PROVIDE CEILING MOUNTED

SPEAKERS AS REQUIRED TO

ACHIEVE DESIGN CRITERIA.

NOTIFICATION APPLIANCES ARE

NOT REQUIRED.

PROVIDE WEATHERPROOF WALL

MOUNTED SPEAKERS, AS REQUIRED

TO ACHIEVE DESIGN CRITERIA.

FIRE ALARM HATCH LEGEND

NO HATCH

F

E

D

C

B

A

7 8 9 10 11 12 13

BREAK

COPY

IMA OFF.

DA6O OFF.

A6O OFF.

VEST.

RESTRM. (W)

A2X / A2F

TELECOMM MAIN

ENTRANCE

FACILITY

FIRE PUMP RM

HALL

ENTRY

ELEC. RM.

CONF.

SECURITY

A3O OPEN OFF.

CONF.

A3O OFF.

IMA OFF.

DA3O OFF.

CORRIDOR

STAIR 01

HALL

MULTIPURPOSE

RM.

MAIN ELECT. RM.

UPS

SIPR VTC CONF.

RM.

RESTRM. (M)

MAIN

MECHANICAL RM.

CORRIDOR

LOBBY

ELEC. RM.

ETF F

F

F

A6O OPEN OFF.

FACU/ACU

LOC

CO

FPC JPC

WF

VS

F

NAC

AMP

S P

WP4

S P

F

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O J E

C T

N O

K

R S

M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

J O

IN

T

O P

E R

A T

IO

N

S

M

IS

S

IO

N P

L A

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

/1

/2

V D

Y D

FA101

C K

N O

F F

A M

O O

R E

M D

A

IL

E Y

/1

/2

J O

M C

F A

.D

W G

F

IR

S T

F L O

O R

F

IR

E A

L A

R M

P L A

N

A R

E A

A

NOTES:

1. REFER TO FA001 FOR GENERAL NOTES,

DESIGN CRITERIA, ABBREVIATIONS AND

SYMBOLS.

2. WALL MOUNTED NOTIFICATION APPLIANCES

ARE PERMITTED IN UNFINISHED AREAS WITH

CONGESTED CEILINGS SUCH AS A PUMP

ROOM, STAIRWELL, OR MECHANICAL ROOM.

KEYED NOTES:

RECESS MOUNT CONTROL UNIT IN WALL.

QUANTITY AND LOCATION OF PANELS BY

CONTRACTOR'S DESIGN TO MEET DESIGN

CRITERIA.

REFER TO FIRE SUPPRESSION DRAWINGS FOR

QUANTITY AND/OR LOCATIONS OF DEVICE(S).

WP HORN/STROBE OVER FDC.

MONITOR FLOW SWITCH AND TAMPER SWITCH

FOR UPS ROOM. ACTUATION OF FLOW SWITCH

SHALL REMOVE POWER TO THE BATTERY

CHARGERS.

SCALE: 1/8" = 1'-0"A1

FIRST FLOOR FIRE ALARM PLAN - AREA A

SCALE IN FEET

0 4' 8' 16'

MATCHLINE - SEE SHEET FA103

M A

T C

H L

IN

E

S E

E S

H E

E T

F A

KEYPLAN (N.T.S.) N

AB

CD

EF

H

G

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C

E R

T

IF

IE

D

F

IN

A L S

U B

M

IT

T A

L D

E C

12/11/2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(1 of 3)

-0

F

D

C

B

A

1 2 3 4 5 6 7

SUP. OFF.

A/V

BREAK OUT RM.

VEST.

ELEV.

E02

ELEV.

E01

PROCESSING

BREAK OUT VTC

RM.

RESTRM. (M)

CORRIDOR

ELEV. EQUIP. RM.

MOTHER'S RM.

CONF. RM.

OPT 3

A3X OPEN OFF.

ELEV. LOBBY

BRIEFING RM.

RESTRM. (W)

CORRIDOR

AUDITORIUM

VEST.

FFCC LOBBY

ETF F

WF VS

S P

S P

JAN.

CORRIDOR

HALL

VEST.

BREAK RM.

FAA

ADMIN.

PROVIDE CEILING MOUNTED

SPEAKERS AND CLEAR STROBES AS

REQUIRED TO ACHIEVE DESIGN

CRITERIA.

PROVIDE CEILING MOUNTED

SPEAKERS AS REQUIRED TO

ACHIEVE DESIGN CRITERIA.

NOTIFICATION APPLIANCES ARE

NOT REQUIRED.

PROVIDE WEATHERPROOF WALL

MOUNTED SPEAKERS, AS REQUIRED

TO ACHIEVE DESIGN CRITERIA.

FIRE ALARM HATCH LEGEND

NO HATCH

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O J E

C T

N O

K

R S

M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

J O

IN

T

O P

E R

A T

IO

N

S

M

IS

S

IO

N P

L A

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

/1

/2

V D

Y D

FA102

C K

N O

F F

A M

O O

R E

M D

A

IL

E Y

/1

/2

J O

M C

F A

.D

W G

F

IR

S T

F L O

O R

F

IR

E A

L A

R M

P L A

N

A R

E A

B

SCALE: 1/8" = 1'-0"A1

FIRST FLOOR FIRE ALARM PLAN - AREA B

NOTES:

1. REFER TO FA001 FOR GENERAL NOTES,

DESIGN CRITERIA, ABBREVIATIONS AND

SYMBOLS.

2. WALL MOUNTED NOTIFICATION APPLIANCES

ARE PERMITTED IN UNFINISHED AREAS WITH

CONGESTED CEILINGS SUCH AS A PUMP

ROOM, STAIRWELL, OR MECHANICAL ROOM.

KEYED NOTES:

MONITOR FLOW SWITCH AND TAMPER SWITCH

FOR ELEVATOR EQUIPMENT ROOM. ACTUATION

OF FLOW SWITCH SHALL REMOVE POWER TO

ELEVATOR BY SHUNT TRIP BREAKER OPERATION

WITH ZERO TIME DELAY. REFER TO FIRE

SUPPRESSION DRAWINGS FOR QUANTITY

AND/OR LOCATIONS OF DEVICE(S).

SCALE IN FEET

0 4' 8' 16'

MATCHLINE - SEE SHEET FA104

M A

T C

H L

IN

E

S E

E S

H E

E T

F A

LOC

KEYPLAN (N.T.S.) N

AB

CD

EF

H

G

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C

E R

T

IF

IE

D

F

IN

A L S

U B

M

IT

T A

L D

E C

12/11/2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(1 of 3)

-0

K

J

H

G

7 8 9 10 11 12 13

STAIR 02

ELEV. EQUIP. RM.

ELEV.

E03

SECURE

TELECOMM

ROOM

RESTRM. (M)

RESTRM.

CORRIDOR

MECH. RM.

1064RESTRM. (M)

JAN.

A6O OPEN OFF.

MOTHER'S RM.

RESTRM. (W)

RECEIVING

STORAGE

MAIL

JWICS VTC CONF.

RM.

RESTRM. (W)

COLLATERAL

TELECOMM

ROOM

ELECT. CLST.

COMMANDER'S

BATTLE STAFF

SEC. VEST.

SECURITY

SECURE SERVER

RM.

CORRIDOR

SECURITY

EQUIPMENT RM.

CORRIDOR

CORRIDOR

CORRIDOR

F

ET

F

FACILITY OFFICE

A2X

A2F DS OFF.

A2F DDC OFF.

A2F DC OFF.

A2X DC OFF.

A2X DDC OFF.

MAIN

MECHANICAL RM.

SECURE SPACE BOUNDARY

LOC

ASD

WF VS

S P

S P

F

BREAK

F

ET

CUSTODIANS

OFFICE

FACILITY

STORAGE

CATV ROOM

PROVIDE CEILING MOUNTED

SPEAKERS AND CLEAR STROBES AS

REQUIRED TO ACHIEVE DESIGN

CRITERIA.

PROVIDE CEILING MOUNTED

SPEAKERS AS REQUIRED TO

ACHIEVE DESIGN CRITERIA.

NOTIFICATION APPLIANCES ARE

NOT REQUIRED.

PROVIDE WEATHERPROOF WALL

MOUNTED SPEAKERS, AS REQUIRED

TO ACHIEVE DESIGN CRITERIA.

FIRE ALARM HATCH LEGEND

NO HATCH

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O J E

C T

N O

K

R S

M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

J O

IN

T

O P

E R

A T

IO

N

S

M

IS

S

IO

N P

L A

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

/1

/2

V D

Y D

FA103

C K

N O

F F

A M

O O

R E

M D

A

IL

E Y

/1

/2

J O

M C

F A

.D

W G

F

IR

S T

F L O

O R

F

IR

E A

L A

R M

P L A

N

A R

E A

C

SCALE: 1/8" = 1'-0"A1

FIRST FLOOR FIRE ALARM PLAN - AREA C

NOTES:

1. REFER TO FA001 FOR GENERAL NOTES,

DESIGN CRITERIA, ABBREVIATIONS AND

SYMBOLS.

2. WALL MOUNTED NOTIFICATION APPLIANCES

ARE PERMITTED IN UNFINISHED AREAS WITH

CONGESTED CEILINGS SUCH AS A PUMP

ROOM, STAIRWELL, OR MECHANICAL ROOM.

3. THE QUANTITY OF FA/MNS PENETRATIONS

INTO THE SECURE SPACE SHALL BE

MINIMIZED AND COORDINATED WITH THE

ELECTRICAL AND MECHANICAL

CONTRACTORS.

KEYED NOTES:

MONITOR FLOW SWITCH AND TAMPER SWITCH

FOR ELEVATOR EQUIPMENT ROOM. ACTUATION OF

FLOW SWITCH SHALL REMOVE POWER TO

ELEVATOR BY SHUNT TRIP BREAKER OPERATION

WITH ZERO TIME DELAY. REFER TO FIRE

SUPPRESSION DRAWINGS FOR QUANTITY AND/OR

LOCATIONS OF DEVICE(S).

PROVIDE EARLY WARNING AIR-SAMPLING SMOKE

DETECTORS AND DISPLAY PANELS AND AIR-

SAMPLING DETECTOR PIPING WITHIN ROOM. TWO

SEPARATE DETECTION ZONES SHALL BE

PROVIDED, ONE AT THE CEILING LEVEL AND ONE

BELOW THE RAISED FLOOR . EACH ZONE SHALL

HAVE ITS OWN PIPING NETWORK AND SAMPLING

PORTS. IF NECESSARY, TWO DETECTION AND

DISPLAY PANELS MAY BE PROVIDED TO MEET

DESIGN CRITERIA.

DO NOT PROVIDE ANY PENETRATIONS THROUGH

THE WEST WALL OF THE MECHANICAL ROOM.

SCALE IN FEET

0 4' 8' 16'

MATCHLINE - SEE SHEET FA105

MATCHLINE - SEE SHEET FA101

M A

T C

H L

IN

E

S

E E

S H

E E

T F

A

KEYPLAN (N.T.S.) N

AB

CD

EF

H

G

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C

E R

T

IF

IE

D

F

IN

A L S

U B

M

IT

T A

L D

E C

12/11/2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(1 of 3)

-0

J

H

G

1 2 3 4 5 6 7

ELECT. CLST.

DA3X OFF.

FFCC SECURED

TELECOMM

ROOM

FFCC STORAGE

MECH. RM.

ADMIN.

DV OFF.

BREAK OUT (L)

IMA OFF.

A3X OFF.

OPT 1

COLLATERAL

TELECOMM

ROOM

DV OFFICE

ELECT. RM.

STAIR 03

1132 VEST

BREAK OUT (S)

ELECT. RM.

EXECUTIVE

CONF.

AIS CC OFF.

JWICS A/V RM.

BREAK OUT (S)

BREAK OUT (S)

NIPR CAFE /

BREAK ROOM

TELECOMM

SECONDARY

ENTRANCE

FACILITY

BREAK OUT (S)

CORRIDOR

BREAK OUT (L)

A3X OPEN OFF.

OPT 2

SECURE SPACE BOUNDARY

D.O. OFF.

AIS FRONT

OFFICE

HALL

F

F

F

F

F

NAC

AMP

S

P

E T

ET

LOC

DV OFFICE

FFCC COLLATERAL TELECOMM RM.

BREAK OUT (S)

BREAK OUT (S)

BREAK OUT (S)

CORRIDOR

E T

PROVIDE CEILING MOUNTED

SPEAKERS AND CLEAR STROBES AS

REQUIRED TO ACHIEVE DESIGN

CRITERIA.

PROVIDE CEILING MOUNTED

SPEAKERS AS REQUIRED TO

ACHIEVE DESIGN CRITERIA.

NOTIFICATION APPLIANCES ARE

NOT REQUIRED.

PROVIDE WEATHERPROOF WALL

MOUNTED SPEAKERS, AS REQUIRED

TO ACHIEVE DESIGN CRITERIA.

FIRE ALARM HATCH LEGEND

NO HATCH

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O J E

C T

N O

K

R S

M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

J O

IN

T

O P

E R

A T

IO

N

S

M

IS

S

IO

N P

L A

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

/1

/2

V D

Y D

FA104

C K

N O

F F

A M

O O

R E

M D

A

IL

E Y

/1

/2

J O

M C

F A

.D

W G

F

IR

S T

F L O

O R

F

IR

E A

L A

R M

P L A

N

A R

E A

D

SCALE: 1/8" = 1'-0"A1

FIRST FLOOR FIRE ALARM PLAN - AREA D

NOTES:

1. REFER TO FA001 FOR GENERAL NOTES,

DESIGN CRITERIA, ABBREVIATIONS AND

SYMBOLS.

2. WALL MOUNTED NOTIFICATION

APPLIANCES ARE PERMITTED IN

UNFINISHED AREAS WITH CONGESTED

CEILINGS SUCH AS A PUMP ROOM,

STAIRWELL, OR MECHANICAL ROOM.

3. THE QUANTITY OF FA/MNS PENETRATIONS

INTO THE SECURE SPACE SHALL BE

MINIMIZED AND COORDINATED WITH THE

ELECTRICAL AND MECHANICAL

CONTRACTORS.

KEYED NOTES:

QUANTITY AND LOCATION OF PANELS BY

CONTRACTOR'S DESIGN TO MEET DESIGN

CRITERIA.

SCALE IN FEET

0 4' 8' 16'

MATCHLINE - SEE SHEET FA106

MATCHLINE - SEE SHEET FA102

M A

T C

H L

IN

E

S E

E S

H E

E T

F A

KEYPLAN (N.T.S.) N

AB

CD

EF

H

G

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C

E R

T

IF

IE

D

F

IN

A L S

U B

M

IT

T A

L D

E C

12/11/2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(1 of 3)

-0

Q

P

N

M

8 9 10 11 12 13

NOC ZONE B

NOC ZONE A

ELECT. RM.

HALL

SECURE RM.

JWICS CAFE

ELECT. RM.

MDT

SECURITY

WORK AREA

OFFICE

A2X

HALL

BREAK RM.

CORRIDOR

HALL

STAIR 05

STAIR 04

OFFICE

A2O

SECURE CONF.

RM.

CONF. RM.

BATTLEWATCH

SS MECHANICAL

RM.

F

MATCHLINE - SEE SHEET FA103

M A

T C

H L

IN

E

S E

E S

H E

E T

F A

F

NAC

AMP S

P

JWICS CONF. RM.

JAN.

VEST.

STORAGE

OFFICE

NOC STOR.

NOC STORAGE

TRAIN.

RESTRM.

BREAK RM.

COS / AMC COM. CTR.

GRAPHICS WORK SPACE

STORAGE

OFFICE

HALL

HALL

A2A

OFFICE

COPY

OFFICE

OFFICE

NAC

AMP S

P

F

ET

ET

PROVIDE CEILING MOUNTED

SPEAKERS AND CLEAR STROBES AS

REQUIRED TO ACHIEVE DESIGN

CRITERIA.

PROVIDE CEILING MOUNTED

SPEAKERS AS REQUIRED TO

ACHIEVE DESIGN CRITERIA.

NOTIFICATION APPLIANCES ARE

NOT REQUIRED.

PROVIDE WEATHERPROOF WALL

MOUNTED SPEAKERS, AS REQUIRED

TO ACHIEVE DESIGN CRITERIA.

FIRE ALARM HATCH LEGEND

NO HATCH

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O J E

C T

N O

K

R S

M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

J O

IN

T

O P

E R

A T

IO

N

S

M

IS

S

IO

N P

L A

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

/1

/2

V D

Y D

FA105

C K

N O

F F

A M

O O

R E

M D

A

IL

E Y

/1

/2

J O

M C

F A

.D

W G

F

IR

S T

F L O

O R

F

IR

E A

L A

R M

P L A

N

A R

E A

E

SCALE: 1/8" = 1'-0"A1

FIRST FLOOR FIRE ALARM PLAN - AREA E

NOTES:

1. REFER TO FA001 FOR GENERAL NOTES, DESIGN

CRITERIA, ABBREVIATIONS AND SYMBOLS.

2. WALL MOUNTED NOTIFICATION APPLIANCES

ARE PERMITTED IN UNFINISHED AREAS WITH

CONGESTED CEILINGS SUCH AS A PUMP ROOM,

STAIRWELL, OR MECHANICAL ROOM.

3. THE QUANTITY OF FA/MNS PENETRATIONS INTO

THE SECURE SPACE SHALL BE MINIMIZED AND

COORDINATED WITH THE ELECTRICAL AND

MECHANICAL CONTRACTORS.

KEYED NOTES:

QUANTITY AND LOCATION OF PANELS BY

CONTRACTOR'S DESIGN TO MEET DESIGN

CRITERIA. PANELS SHALL ONLY SUPPLY DEVICES

IN THE SECURE SPACE.

SCALE IN FEET

0 4' 8' 16'

SECURE SPACE BOUNDARY

KEYPLAN (N.T.S.) N

AB

CD

EF

H

G

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C

E R

T

IF

IE

D

F

IN

A L S

U B

M

IT

T A

L D

E C

12/11/2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(1 of 3)

-0

P

N

M

4 5 6 7

BREAK OUT (L)

BREAK OUT (L)

VEST.

EXECUTIVE

CONF.

BREAK OUT (S)

BREAK OUT (S)

BREAK OUT (L)

HALL

SEA OFF.

CORRIDOR

WORK ROOM

F

F

E T

E T

SECURE SPACE BOUNDARY

AIS FRONT

OFFICE

MAIL / COPY

STORAGE

BREAK OUT (L)

WORK ROOM

WORK ROOM

CONF. RM.

CONF. RM.

VEST.

PROVIDE CEILING MOUNTED

SPEAKERS AND CLEAR STROBES AS

REQUIRED TO ACHIEVE DESIGN

CRITERIA.

PROVIDE CEILING MOUNTED

SPEAKERS AS REQUIRED TO

ACHIEVE DESIGN CRITERIA.

NOTIFICATION APPLIANCES ARE

NOT REQUIRED.

PROVIDE WEATHERPROOF WALL

MOUNTED SPEAKERS, AS REQUIRED

TO ACHIEVE DESIGN CRITERIA.

FIRE ALARM HATCH LEGEND

NO HATCH

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O J E

C T

N O

K

R S

M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

J O

IN

T

O P

E R

A T

IO

N

S

M

IS

S

IO

N P

L A

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

/1

/2

V D

Y D

FA106

C K

N O

F F

A M

O O

R E

M D

A

IL

E Y

/1

/2

J O

M C

F A

.D

W G

F

IR

S T

F L O

O R

F

IR

E A

L A

R M

P L A

N

A R

E A

F

SCALE: 1/8" = 1'-0"A1

FIRST FLOOR FIRE ALARM PLAN - AREA F

NOTES:

1. REFER TO FA001 FOR GENERAL NOTES, DESIGN

CRITERIA, ABBREVIATIONS AND SYMBOLS.

2. WALL MOUNTED NOTIFICATION APPLIANCES

ARE PERMITTED IN UNFINISHED AREAS WITH

CONGESTED CEILINGS SUCH AS A PUMP ROOM,

STAIRWELLS, OR MECHANICAL ROOM.

3. THE QUANTITY OF FA/MNS PENETRATIONS INTO

THE SECURE SPACE SHALL BE MINIMIZED AND

COORDINATED WITH THE ELECTRICAL AND

MECHANICAL CONTRACTORS.

SCALE IN FEET

0 4' 8' 16'

MATCHLINE - SEE SHEET FA104

M A

T C

H L

IN

E

S

E E

S H

E E

T F

A

KEYPLAN (N.T.S.) N

AB

CD

EF

H

G

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C

E R

T

IF

IE

D

F

IN

A L S

U B

M

IT

T A

L D

E C

12/11/2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(1 of 3)

-0

D

C

B

7 8 9 10 11 12 13

HALL

DEPUTY A3

CONF. RM.

ELECT. RM.

CM SGT OFF.

IMA O-6

CONF. RM.

R.A.OFF.

G.A. OFF.

ELECT. RM.

HALL

SRD DD OFF.

COPY

COPY

1ST SGT OFF.

CCQ/CCEA CMDR

HALL

WAITING

CORRIDOR

JA

AOC COMMAND

SUITE

CHIEF OF STAFF

SAFETY REP.

BRIEFING RM.

M. ASSIST. OFF.

CONF. RM.

VICE

COMMANDER

COMMANDER

2025 RESTRM.

SRD DIR. OFF.

RESTRM. (M)

AMC-DA3

COMMAND SUITE

IMA OFF.

AOC OPEN

OFFICE -

SOUTHWEST

RESTRM. (W)

HALL

CORRIDOR

CORRIDOR

NAC

AMP S

P

L O

C

RESTRM.

VEST.

COFFEE

COPY

OPEN TO BELOW

STAIR 01

E T

PROVIDE CEILING MOUNTED

SPEAKERS AND CLEAR STROBES AS

REQUIRED TO ACHIEVE DESIGN

CRITERIA.

PROVIDE CEILING MOUNTED

SPEAKERS AS REQUIRED TO

ACHIEVE DESIGN CRITERIA.

NOTIFICATION APPLIANCES ARE

NOT REQUIRED.

FIRE ALARM HATCH LEGEND

NO HATCH

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O J E

C T

N O

K

R S

M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

J O

IN

T

O P

E R

A T

IO

N

S

M

IS

S

IO

N P

L A

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

/1

/2

V D

Y D

FA201

C K

N O

F F

A M

O O

R E

M D

A

IL

E Y

/1

/2

J O

M C

F A

.D

W G

S E

C O

N D

F L O

O R

F

IR

E A

L A

R M

P L A

N

A R

E A

A

SCALE: 1/8" = 1'-0"A1

SECOND FLOOR FIRE ALARM PLAN - AREA A

NOTES:

1. REFER TO FA001 FOR GENERAL NOTES, DESIGN

CRITERIA, ABBREVIATIONS AND SYMBOLS.

2. WALL MOUNTED NOTIFICATION APPLIANCES

ARE PERMITTED IN UNFINISHED AREAS WITH

CONGESTED CEILINGS SUCH AS A PUMP ROOM,

STAIRWELLS, OR MECHANICAL ROOM.

KEYED NOTES:

QUANTITY AND LOCATION OF PANELS

CONTRACTOR'S DESIGN TO MEET DESIGN

CRITERIA.

SCALE IN FEET

0 4' 8' 16'

MATCHLINE - SEE SHEET FA203

M A

T C

H L

IN

E

S E

E S

H E

E T

F A

KEYPLAN (N.T.S.) N

AB

CD

EF

H

G

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C

E R

T

IF

IE

D

F

IN

A L S

U B

M

IT

T A

L D

E C

12/11/2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(1 of 3)

-0

D

C

4 5 6 7

ARD FRONT OFF.

ALD DD OFF.

ALD EXEC. OFF.

HALL

ARD DD OFF.

ARD DIR. OFF.

HALL

ARD EXEC. OFF.

ARD EXEC. OFF.

ELEV.

E02

ELEV. LOBBY

S P

PROVIDE CEILING MOUNTED

SPEAKERS AND CLEAR STROBES AS

REQUIRED TO ACHIEVE DESIGN

CRITERIA.

PROVIDE CEILING MOUNTED

SPEAKERS AS REQUIRED TO

ACHIEVE DESIGN CRITERIA.

NOTIFICATION APPLIANCES ARE

NOT REQUIRED.

FIRE ALARM HATCH LEGEND

NO HATCH

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O J E

C T

N O

K

R S

M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

J O

IN

T

O P

E R

A T

IO

N

S

M

IS

S

IO

N P

L A

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

/1

/2

V D

Y D

FA202

C K

N O

F F

A M

O O

R E

M D

A

IL

E Y

/1

/2

J O

M C

F A

.D

W G

S E

C O

N D

F L O

O R

F

IR

E A

L A

R M

P L A

N

A R

E A

B

NOTES:

1. REFER TO FA001 FOR GENERAL NOTES, DESIGN

CRITERIA, ABBREVIATIONS AND SYMBOLS.

2. WALL MOUNTED NOTIFICATION APPLIANCES ARE

PERMITTED IN UNFINISHED AREAS WITH

CONGESTED CEILINGS SUCH AS A PUMP ROOM,

STAIRWELL, OR MECHANICAL ROOM.

SCALE: 1/8" = 1'-0"A1

SECOND FLOOR FIRE ALARM PLAN - AREA B

SCALE IN FEET

0 4' 8' 16'

MATCHLINE - SEE SHEET FA204

M A

T C

H L

IN

E

S E

E S

H E

E T

F A

KEYPLAN (N.T.S.) N

AB

CD

EF

H

G

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C

E R

T

IF

IE

D

F

IN

A L S

U B

M

IT

T A

L D

E C

12/11/2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(1 of 3)

-0

J

H

G

7 8 9 10 11 12 13

HALL

CORRIDOR

CORRIDOR

AOC OPEN

OFFICE -

SOUTHEAST

CCQ SERVICE

DESKS

SHARED

CONFERENCE

ROOM

ACOMS DD OFF.

HALL

ACOMS EXEC.

OFF.

2069ACOMS DIR. OFF.

COLLATERAL

TELECOMM

ROOM

ELECT. RM.

CS FRONT OFF.

MAIN CONF. RM.

MECH. RM.

RESTRM. (M)

CORRIDOR

ITAMS STORAGE

CONTING. RC

2082 HELP DESK

HALL

MAINT. LAB

ELECT. RM.

ELEV.

E03 STAIR 02

CCQ/CCEA OFF.

UDM OFF.

RESTRM. (W)

MOTHER'S RM.

RESTRM.

JAN.

NAC

AMP

S P

S P

LOC

ELECT. RM.

A/V RACK RM.

CS DIR. OFF.

CS SUP. OFF.

COPY / COFFEE

CS DD OFF.

A/V OPERATORS

WXD DD OFF.

WXD DIR. OFF.

ET

PROVIDE CEILING MOUNTED

SPEAKERS AND CLEAR STROBES AS

REQUIRED TO ACHIEVE DESIGN

CRITERIA.

PROVIDE CEILING MOUNTED

SPEAKERS AS REQUIRED TO

ACHIEVE DESIGN CRITERIA.

NOTIFICATION APPLIANCES ARE

NOT REQUIRED.

FIRE ALARM HATCH LEGEND

NO HATCH

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O J E

C T

N O

K

R S

M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

J O

IN

T

O P

E R

A T

IO

N

S

M

IS

S

IO

N P

L A

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

/1

/2

V D

Y D

FA203

C K

N O

F F

A M

O O

R E

M D

A

IL

E Y

/1

/2

J O

M C

F A

.D

W G

S E

C O

N D

F L O

O R

F

IR

E A

L A

R M

P L A

N

A R

E A

C

NOTES:

1. REFER TO FA001 FOR GENERAL NOTES, DESIGN

CRITERIA, ABBREVIATIONS AND SYMBOLS.

2. WALL MOUNTED NOTIFICATION APPLIANCES ARE

PERMITTED IN UNFINISHED AREAS WITH

CONGESTED CEILINGS SUCH AS A PUMP ROOM,

STAIRWELL, OR MECHANICAL ROOM.

KEYED NOTES:

QUANTITY AND LOCATION OF PANELS BY

CONTRACTOR'S DESIGN TO MEET DESIGN

CRITERIA.

DO NOT PROVIDE ANY PENETRATIONS THROUGH

THE WEST WALL OF THE MECHANICAL ROOM.

SCALE: 1/8" = 1'-0"A1

SECOND FLOOR FIRE ALARM PLAN - AREA C

SCALE IN FEET

0 4' 8' 16'

MATCHLINE - SEE SHEET FA201

MATCHLINE - SEE SHEET FA205

M A

T C

H L

IN

E

S E

E S

H E

E T

F A

KEYPLAN (N.T.S.) N

AB

CD

EF

H

G

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C

E R

T

IF

IE

D

F

IN

A L S

U B

M

IT

T A

L D

E C

12/11/2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(1 of 3)

-0

J

H

G

4 5 6 7

O-5/GS-14 OFF.

O-5/GS-14 OFF.

COLLATERAL

TELECOMM

ROOM

CORRIDOR

AOC OPEN

OFFICE -

NORTHEAST

ELECT. RM.

O-5/GS-14 OFF.

O-5/GS-14 OFF.

2108O-5/GS-14 OFF.

O-6/GS-15 OFF.

ALD DIR. OFF.

LOC

ET

PROVIDE CEILING MOUNTED

SPEAKERS AND CLEAR STROBES AS

REQUIRED TO ACHIEVE DESIGN

CRITERIA.

PROVIDE CEILING MOUNTED

SPEAKERS AS REQUIRED TO

ACHIEVE DESIGN CRITERIA.

NOTIFICATION APPLIANCES ARE

NOT REQUIRED.

FIRE ALARM HATCH LEGEND

NO HATCH

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O J E

C T

N O

K

R S

M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

J O

IN

T

O P

E R

A T

IO

N

S

M

IS

S

IO

N P

L A

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

/1

/2

V D

Y D

FA204

C K

N O

F F

A M

O O

R E

M D

A

IL

E Y

/1

/2

J O

M C

F A

.D

W G

S E

C O

N D

F L O

O R

F

IR

E A

L A

R M

P L A

N

A R

E A

D

SCALE: 1/8" = 1'-0"A1

SECOND FLOOR FIRE ALARM PLAN - AREA D

NOTES:

1. REFER TO FA001 FOR GENERAL NOTES, DESIGN

CRITERIA, ABBREVIATIONS AND SYMBOLS.

2. WALL MOUNTED NOTIFICATION APPLIANCES ARE

PERMITTED IN UNFINISHED AREAS WITH

CONGESTED CEILINGS SUCH AS A PUMP ROOM,

STAIRWELL, OR MECHANICAL ROOM.

SCALE IN FEET

0 4' 8' 16'

MATCHLINE - SEE SHEET FA206

M A

T C

H L

IN

E

S E

E S

H E

E T

F A

MATCHLINE - SEE SHEET FA202

KEYPLAN (N.T.S.) N

AB

CD

EF

H

G

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C

E R

T

IF

IE

D

F

IN

A L S

U B

M

IT

T A

L D

E C

12/11/2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(1 of 3)

-0

P

N

M

L

7 8 9 10 11 12 13

AOC OPS FLOOR

MOD DIV. CHF.

MOD DIV. CHF.

HALL

MOD DD OFF.

MOD DIV. CHF.

RADIO ROOM

COPY

ELECT. RM.

HALL

STAIR 04

STAIR 05

SECURE

TELECOMM

ROOM

JWICS CONF. RM

COLLATERAL

SERVER ROOM

HALL

ALDS

ISRD / SRDI / A3DI

/ SRDP

JWICS CAFE

CONF. RM.

ISRD DD OFF.

ISRD DIR. OFF.

NAC

AMP S

P

L O

C

ASD

ASD

SECURE SPACE BOUNDARY

F A

C

ALDL

CONF. RM.

VEST.

VEST.

COFFEE

HALL

HALL

MOD SECT. OFF.

MOD DIR. OFF.

ET

PROVIDE CEILING MOUNTED

SPEAKERS AND CLEAR STROBES AS

REQUIRED TO ACHIEVE DESIGN

CRITERIA.

PROVIDE CEILING MOUNTED

SPEAKERS AS REQUIRED TO

ACHIEVE DESIGN CRITERIA.

NOTIFICATION APPLIANCES ARE

NOT REQUIRED.

FIRE ALARM HATCH LEGEND

NO HATCH

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O J E

C T

N O

K

R S

M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

J O

IN

T

O P

E R

A T

IO

N

S

M

IS

S

IO

N P

L A

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

/1

/2

V D

Y D

FA205

C K

N O

F F

A M

O O

R E

M D

A

IL

E Y

/1

/2

J O

M C

F A

.D

W G

S E

C O

N D

F L O

O R

F

IR

E A

L A

R M

P L A

N

A R

E A

E

NOTES:

1. REFER TO FA001 FOR GENERAL NOTES, DESIGN

CRITERIA, ABBREVIATIONS AND SYMBOLS.

2. WALL MOUNTED NOTIFICATION APPLIANCES ARE

PERMITTED IN UNFINISHED AREAS WITH

CONGESTED CEILINGS SUCH AS A PUMP ROOM,

STAIRWELL, OR MECHANICAL ROOM.

3. THE QUANTITY OF FA/MNS PENETRATIONS INTO

THE SECURE SPACE SHALL BE MINIMIZED AND

COORDINATED WITH THE ELECTRICAL AND

MECHANICAL CONTRACTORS.

KEYED NOTES:

QUANTITY AND LOCATION OF PANELS BY

CONTRACTOR'S DESIGN TO MEET DESIGN

CRITERIA.

PROVIDE EARLY WARNING AIR-SAMPLING SMOKE

DETECTORS AND DISPLAY PANELS AND AIR-

SAMPLING DETECTOR PIPING WITHIN ROOM. TWO

SEPARATE DETECTION ZONES SHALL BE

PROVIDED, ONE AT THE CEILING LEVEL AND ONE

BELOW THE RAISED FLOOR . EACH ZONE SHALL

HAVE ITS OWN PIPING NETWORK AND SAMPLING

PORTS. IF NECESSARY, TWO DETECTION AND

DISPLAY PANELS MAY BE PROVIDED TO MEET

DESIGN CRITERIA.

MOUNT ANTENNA TWO FEET ABOVE ROOF. SEE

DETAIL B1/FA501.

SCALE: 1/8" = 1'-0"A1

SECOND FLOOR FIRE ALARM PLAN - AREA E

SCALE IN FEET

0 4' 8' 16'

M A

T C

H L

IN

E

S E

E S

H E

E T

F A

MATCHLINE - SEE SHEET FA203

KEYPLAN (N.T.S.) N

AB

CD

EF

H

G

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C

E R

T

IF

IE

D

F

IN

A L S

U B

M

IT

T A

L D

E C

12/11/2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(1 of 3)

-0

P

N

M

L

K

4 5 6 7

OPEN OFFICE

HALL

AOC BRK. RM.

ALDPA DIV. CHF

ALDPA OFF.

MOD DIV. CHF.

MOD O-6

HALL

MOD GS-15

GAD DIR. OFF.

HALL

GAD EXEC. OFF.

GAD DD OFF.

AAD EXEC. OFF.

AAD DIR. OFF.

AAD DD OFF.

MOD DIV. CHF.

MOD DIV. CHF.

HALL

AOC OPS BRK. RM.

HALL

WXD OFF.

WXD OFF.

STAIR 03

PROVIDE CEILING MOUNTED

SPEAKERS AND CLEAR STROBES AS

REQUIRED TO ACHIEVE DESIGN

CRITERIA.

PROVIDE CEILING MOUNTED

SPEAKERS AS REQUIRED TO

ACHIEVE DESIGN CRITERIA.

NOTIFICATION APPLIANCES ARE

NOT REQUIRED.

FIRE ALARM HATCH LEGEND

NO HATCH

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O J E

C T

N O

K

R S

M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

J O

IN

T

O P

E R

A T

IO

N

S

M

IS

S

IO

N P

L A

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

/1

/2

V D

Y D

FA206

C K

N O

F F

A M

O O

R E

M D

A

IL

E Y

/1

/2

J O

M C

F A

.D

W G

S E

C O

N D

F L O

O R

F

IR

E A

L A

R M

P L A

N

A R

E A

F

NOTES:

1. REFER TO FA001 FOR GENERAL NOTES, DESIGN

CRITERIA, ABBREVIATIONS AND SYMBOLS.

2. WALL MOUNTED NOTIFICATION APPLIANCES ARE

PERMITTED IN UNFINISHED AREAS WITH

CONGESTED CEILINGS SUCH AS A PUMP ROOM,

STAIRWELL, OR MECHANICAL ROOM.

SCALE: 1/8" = 1'-0"A1

SECOND FLOOR FIRE ALARM PLAN - AREA F

SCALE IN FEET

0 4' 8' 16'

MATCHLINE - SEE SHEET FA204

M A

T C

H L

IN

E

S E

E S

H E

E T

F A

KEYPLAN (N.T.S.) N

AB

CD

EF

H

G

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C

E R

T

IF

IE

D

F

IN

A L S

U B

M

IT

T A

L D

E C

12/11/2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(1 of 3)

-0

3 FT (MIN)

FOR CEILING HEIGHTS LESS

THAN 96 INCHES THE VISIBLE

LENS MOUNTING HEIGHT

SHALL BE WITHIN 6 INCHES

OF THE CEILING

TO EXIT DOOR

5 FT (MAX)

SYNCHRONIZE TWO

OR MORE

APPLIANCES IN ANY

FIELD OF VIEW

I

N C

H E

S

WALL MOUNTED SMOKE

DETECTOR

CEILING MOUNTED

SMOKE DETECTOR

SUPPLY OR

RETURN

DIFFUSER

CEILING

FINISHED FLOOR

WALL

MOUNTED

VISIBLE

APPLIANCE

MINIMUM 12 INCHES

FROM LIGHT SWITCH

PULL STATIONS SHALL NOT BE

LOCATED BEHIND DOOR SWINGS.

BATT BATT

NAC

NAC

AMP

AMP

BATT

FACU/

ACU

ROUTE CONDUIT TO ACHIEVE SEPARATION OF POWER-

LIMITED FIRE ALARM CIRCUITS AND POWER CIRCUITS

IN

S

T A

L L N

O G

R E

A T

T

H A

N

I

N C

H E

S A

F F

F

LOC

SS SS

CEILING MOUNTED

VISIBLE APPLIANCE

AUDIBLE

ONLY

WALL

MOUNTED

APPLIANCE

M O

U N

T A

S I

N D

IC

A

T

P

R J

O B

S P

E C

IF

IC

A T

IO

N

4 INCHES

(MIN)

ET

3 FT (MIN)

CARBON MONOXIDE

DETECTOR

INCHES

MAX

ASD

BATT

FAC

SS

INCHES

MAX

FAA

12 INCHES

(MAX)

LOCATE ANTENNA TO

MAXIMIZE RADIO SIGNAL

TRANSMISSION/ RECEPTION

AND TO OPTIMIZE

MAINTAINABILITY

FIRE ALARM ANTENNA

BUILDING ROOF

TO FAC

STRAP CONDUIT WITHIN 36

INCHES OF FITTINGS AND 120

INCHES O.C. WITH STAINLESS

STEEL FASTENERS INTO WALL

MOUNT ANTENNA TO

WITHSTAND 100 MPH

WIND VELOCITY

BUILDING EXTERIOR WALL

LIGHTNING

ARRESTER WITH

ENCLOSURE PIPE

PENETRATION

TO GROUNDING WIRE

. 2

IN

C

H E

S

FACU/ACU

FIRE ALARM

DEVICES

FLOOR 1

FLOOR 2

IM IM

FIRE ALARM

DEVICES

CEILING

FINISHED FLOOR

60" MAX

48" MIN

PROVIDE ASD TEST PORT IN

AN ACCESSIBLE LOCATION.

SAMPLE

PORTS

(TYP)

SAMPLING PIPE

LABELED IAW

NFPA 72

60" MAX

SUPPORT FROM RAISED FLOOR

LEG NEAR TOP SPACE (TYP).

ASD

CRAC

UNIT

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

SHEET ID

P R

O J E

C T

N O

K

R S

M

S C

O T

T A

IR

F

O R

C E

B A

S E

IL

L

IN

O

IS

J O

IN

T

O P

E R

A T

IO

N

S

M

IS

S

IO

N P

L A

N N

IN

G

C E

N T

M

P C

A S

S H

O W

N

C E

R T

IF

IE

D F

IN

A

L

IS

S

U E

D F

O R

B

ID

1 753 92 864 10

A

B

C

D

E

F

G

/1

/2

V D

Y D

FA501

C K

N O

F F

A M

O O

R E

M D

A

IL

E Y

/1

/2

J O

M C

F A

.D

W G

F

IR

E A

L A

R M

D E

T A

IL

S

NTSSCALE:E1

TYPICAL MOUNTING DETAIL

NTSSCALE:B1

MONACO ANTENNA MOUNTING DETAIL

NTSSCALE:B2

CLASS B ISOLATION MODULE MOUNTING

NTSSCALE:B3

TYPICAL ASD MOUNTING DETAIL

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C

E R

T

IF

IE

D

F

IN

A L S

U B

M

IT

T A

L D

E C

12/11/2020

CONTROLLED UNCLASSIFIED INFORMATION

CONTROLLED UNCLASSIFIED INFORMATION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns _V ol _I

II_

(1 of 3)

-0

NOTES: KEYED NOTES:

24 VDC POWER CIRCUIT

VISIBLE NOTIFICATION APPLIANCE CIRCUIT (CLASS B)

AUDIBLE NOTIFICATION APPLIANCE CIRCUIT (CLASS B)

SIGNALING LINE CIRCUIT (CLASS B)

CIRCUIT LEGEND:

INITIATING DEVICE CIRCUITS

1. REFER TO FA001 FOR GENERAL NOTES, DESIGN

CRITERIA, ABBREVIATIONS, AND SYMBOLS.

2. THE FIRE ALARM RISER SHOWS THE INTENT OF

THE FIRE ALARM INFRASTRUCTURE. NOT ALL

DEVICES ARE SHOWN. PROVIDE THE QUANTITY

OF DEVICES AS REQUIRED TO COMPLY WITH

NFPA 72, UFC 3-600-01, UFC 4-021-01, ICD/ICS 705,

UFC 4-010-05, ETL 01-18 AND CONTRACT

DOCUMENTS.

3. PROVIDE A SEPARATE ADDRESS FOR EACH

SPRINKLER WATERFLOW SWITCH. NO MORE

THAN 5 ADJACENT TAMPER SWITCHES WITHIN

THE SAME ROOM ARE PERMITTED TO BE

MONITORED BY THE SAME ADDRESSABLE DEVICE

OR SUPERVISORY CIRCUIT.

MOUNT RADIO TRANSCEIVER ANTENNA PER

MANUFACTURERS RECOMMENDATION. PROVIDE #6

BARE COPPER TO 3/4" X 10'-0" COPPER CLAD

GROUND ROD AND TO BUILDING COUNTERPOISE,

AND LIGHTNING ARRESTOR KIT.

RED, LOCKABLE BREAKER LABELED "FIRE ALARM"

PROVIDED BY DIVISION 26. SEE ELECTRICAL PLANS

FOR ADDITIONAL INFORMATION.

QUANTITY AND LOCATION BY CONTRACTOR'S

DESIGN TO MEET DESIGN CRITERIA.

REFER TO FIRE SUPPRESSION DRAWINGS FOR

QUANTITY AND / OR LOCATIONS OF DEVICE(S).

REFER TO FIRE ALARM PLANS FOR QUANTITY AND /

OR LOCATIONS OF DEVICE(S).

PROVIDE ADDRESSABLE INPUT AND/OR OUTPUT

MODULE(S) AS REQUIRED TO ACHIEVE THE

FUNCTIONALITY INDICATED IN THE FIRE ALARM

MATRIX.

PROVIDE ADDITIONAL BOOSTER PANELS AS

REQUIRED PER CONTRACTOR'S DESIGN. WHERE

ADDITIONAL BOOSTER PANELS ARE REQUIRED

LOCATED AS INDICATED ON PLAN.

PROVIDE ADDITIONAL AMPLIFIERS AS REQUIRED PER

CONTRACTOR'S DESIGN. WHERE ADDITIONAL

AMPLIFIERS ARE REQUIRED LOCATED AS INDICATED

ON PLAN.

PROVIDE SUPPLY DUCT SMOKE…