Addendum_1_Attachement_Pre-Renovation_Hazardous_Materials_Survey_Report 1 .pdf
PDF 7 MB Posted
- Attached to
- IDIQ MATOC CONTRACT FOR 109TH AIRLIFT WING
- Solicitation number
- W912PQ15R0006
About this file
Pre-Renovation Hazardous Survey Report
View the file
Other files
| File | Type | Posted |
|---|---|---|
| AMEND_2.pdf | ||
| Exhibit_B.docx | DOCX document | |
| 2015_05_20_-_Bldg_1_-_Addendum_2_final.pdf | ||
| Addendum_2_MATOC_Site_Visit_Attendance_List.pdf | ||
| ADDENDUM_1_-_MATOC.docx | DOCX document | |
| 2nd_site_visit.docx | DOCX document | |
| Pre-prosoal_confence_and_site_visit_attendance.pdf | ||
| MATOC_PRE-PROPOSAL_MTG.pptx | PPTX presentation | |
| Pre-Performance_Conference_ _Site_Visit_Minutes.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Pre-Renovation Hazardous Materials Survey Report
Building 1
Stratton National Guard Base Schenectady, New York
CHA Project Number: 23367.1000.31000
Prepared for:
Stratton Air National Guard
109 AW-NY Air National Guard Schenectady, New York 12302
Prepared by:
III Winners Circle Albany, New York 12205
Phone: (518) 453-4500
April 12, 2012
V:\Projects\ANY\K2\23367\Reports\Hazmat Report\Hazardous Material Survey Report.doc
Air National Guard Building 1 CHA Project No. 23367 Page i
QUALIFICATIONS AND CERTIFICATION STATEMENT
This Pre-Renovation Hazardous Materials Survey Report was compiled by a qualified environmental scientist who is also a NYS-certified asbestos inspector employed by CHA.
This report has been prepared expressly for the use of the Air National Guard. No other parties are entitled to rely upon this report unless our express written consent is first obtained. All conclusions drawn were based on CHA’s review of available historical data, field inspection and analytical results from sampling performed during the course of this project. Recommendations are submitted based on CHA's knowledge, experience, and professional judgment.
Inspection and Report Completed By:
James Morey Scientist III
Report Reviewed By:
Seth H. Fowler, CHMM
Associate
CHA Project No. 23367 Page ii
TABLE OF CONTENTS
1.0 INTRODUCTION
2.0 SCOPE OF WORK
2.1 Asbestos-Containing Materials Survey
2.2 Lead-Based Paint Survey
2.3 Mercury Containing Item Inventory
2.4 PCB Light Ballast/Fluorescent Light Tubes Inventory
2.5 Limitations
3.0 HAZARDOUS MATERIALS SURVEY
3.1 Record Review
3.2 ACM Survey
3.3 LBP Survey
3.4 Mercury Containing Items Inventory
3.5 PCB Light Ballast/Fluorescent Light Tube Inventory
4.0 RESULTS
5.0 CONCLUSIONS AND RECOMMENDATIONS
5.1 Conclusions
5.2 Recommendations
LIST OF TABLES
Table 4-1 Confirmed Asbestos-Containing Materials Summary
LIST OF FIGURES
Figure 1 First Floor Sample Location Plan Figure 2 Second Floor Sample Location Plan
LIST OF APPENDICES
Appendix A Asbestos-Containing Material and LBP Tables – Building 1 Appendix B Historical Asbestos Information Appendix C Current Bulk Asbestos Sample Analysis Appendix D Paint Chip Sample Analysis Appendix E Personnel and Laboratory Licenses
CHA Project No. 23367 Page 1
1.0 INTRODUCTION
CHA was retained by the Stratton Air National Guard to complete a pre-renovation hazardous materials survey of all accessible interior portions and limited exterior portions of Building 1 on the Stratton National Guard Base (NGB) located in Schenectady, New York. This survey was performed to support the renovations, currently in development, which will impact floors, walls, ceilings and mechanical systems throughout the subject building.
This survey report consists of five sections, including this Introduction. Section 2.0 presents the Scope of Work, which outlines the parameters by which this project was performed and the limitations that were encountered. Section 3.0 – Hazardous Materials Survey, details the findings of the pre-renovation asbestos building inspection, lead-based paint chip sampling, mercury-containing item inventory, and PCB-containing equipment inventory. Section 4.0 presents a brief overview of the inspection results while Section 5.0 presents CHA’s conclusions and recommendations regarding the status of the building that was inspected.
2.0 SCOPE OF WORK
2.1 ASBESTOS-CONTAINING MATERIALS SURVEY
The pre-renovation asbestos-containing material (ACM) survey was performed according to the scope of work provided below. All work has been completed in accordance with federal, state, and local regulations.
CHA provided a New York State Department of Labor-certified asbestos building inspector responsible for the identification and assessment of the condition, location and quantity of suspect asbestos-containing materials associated with the accessible areas within the subject building scheduled to be renovated. The inspector collected bulk samples of identified suspect asbestos-containing material following the protocols referenced in 40 CFR Part 763.86 Subpart E (AHERA).
All bulk samples were analyzed at an accredited laboratory licensed by the New York State Department of Health (NYSDOH) Environmental Laboratory Program (ELAP) as well as the National Voluntary Laboratory Accreditation Program (NVLAP) for the analysis of asbestos bulk samples.
2.2 LEAD-BASED PAINT SURVEY
The investigation was conducted to identify Lead-Based Paint (LBP) surfaces and/or sub layers
CHA Project No. 23367 Page 2 associated with Building 1. Paint chip samples were collected at random locations within subject areas and all samples were analyzed for percent lead content using Method 6010B for percent lead in paint.
It should be noted that the lead-based paint survey is intended to assess the need for the safe and proper management of painted surfaces during the renovations throughout the building. The survey and the resultant sample data are not meant to assess building occupant exposure or to represent a risk assessment.
2.3 MERCURY CONTAINING ITEM INVENTORY
A room by room survey was performed to determine the presence of items that may contain mercury. The survey was visual in nature and did not include testing of materials to determine mercury content. The visual survey included items such as thermostats and switches.
2.4 PCB LIGHT BALLAST/FLUORESCENT LIGHT TUBE INVENTORY
A visual survey was made to determine whether fluorescent light ballasts contain PCBs and for the presence of fluorescent light tubes within the project areas of the subject building. Determination of PCBs was made by visually checking a representative number of ballasts. If the ballasts were labeled as containing “No PCBs”, then they were considered to contain no PCBs, however, if they did not have a label stating “No PCBs” they are assumed to contain PCBs.
2.5 LIMITATIONS
The renovations planned throughout Building 1 are still in the schematic design phase thus CHA attempted to inspect all interior portions of the building. Based on conversations with the project team, the bathrooms and recruitment office suite have been recently renovated and were considered “out of scope” for this pre-renovation survey. Based on this, CHA recorded the suspect materials observed in these spaces however no bulk samples were collected. The roof systems were excluded from the scope of work as the renovations are not expected to impact roof levels. See Figures 1 and 2 for the inspected portions of the building and bulk sample locations.
CHA Project No. 23367 Page 3
3.0 HAZARDOUS MATERIALS SURVEY
CHA’s background research and field observations during the site inspection with regard to suspect hazardous building materials associated with the subject building at Stratton NGB are discussed below.
3.1 RECORD REVIEW
The Air National Guard Readiness Center (ANGRC) Civil Engineering Unit Technical Services Center’s Asbestos Management Team completed an Asbestos Management Report for the Stratton National Guard Base in February/March 1996. This management plan was provided to CHA prior to the survey fieldwork and was referenced during bulk sample collection.
Based on this historical documentation, CHA determined that the thermal system insulation on heating and plumbing lines is asbestos-containing and therefore collected no additional samples of pipe insulation. Four 12” x 12” floor tiles and their respective mastics were identified as suspect for asbestos during the asbestos management plan and single samples were collected for each material.
Since the completion of the management plan in 1996, the United States Environmental Protection Agency (EPA) and New York State Department of Health clarified their bulk sample collection criteria with regard to number of acceptable samples per material and analytical methodology used for laboratory analysis. Based on the updated interpretation of both the state and federal asbestos regulations, CHA collected additional samples of floor tiles and their respective mastics.
3.2 ACM SURVEY
CHA performed a pre-renovation asbestos-containing material survey of accessible interior and exterior portions of Building 1 that will be impacted by the upcoming renovations, with exception of those areas discussed in Section 2.5. The renovations consist of the reconfiguration of interior spaces, mechanical and electrical upgrades, and the creation of new office suites.
Building 1 is a two-story brick building which was built in 1951 and consists of first floor medical and dental suites, administrative offices, conference rooms, break rooms, and bathrooms. The exterior elevation of the building was observed to have a single vintage of windows and doors sealed with one type of suspect frame caulk. A vertical expansion joint was observed extending from grade level to roof level and had a caulk filler which is also suspect for asbestos. The window and expansion joint caulk were quantified and sampled for asbestos laboratory analysis.
CHA Project No. 23367 Page 4
The mechanical room and adjoining crawlspace (accessible from the exterior of the building) were inspected for suspect asbestos-containing materials. CHA observed non-suspect fiberglass insulation and PVC fittings throughout both spaces and no suspect asbestos insulation debris was observed on the dirt floor throughout the crawlspace. Steam tunnel access was located below the stairs on the first floor. Previously-confirmed asbestos-containing thermal system insulation and mudded fitting insulation was observed on piping running within this tunnel. It is assumed that this tunnel runs the length of the building and branches to connect with the boiler room and crawlspace entrance.
The first and second floors consist of medical and dental suites of examination rooms, offices, bathrooms, and storage rooms, staff offices, and utility rooms and are very uniform in building materials. The floors are a combination of suspect 9” x 9” and 12” x 12” floor tile (and mastic), 4” cove base (and mastic) and carpeting with limited areas of multiple layers of floor tile. The walls throughout the building are suspect sheetrock and joint compound with older suspect wall plaster behind the sheetrock. The ceilings are a combination of suspect 2’ x 2’ and 2’ x 4’ drop ceiling tiles.
The bathrooms have ceramic tiled floors and walls with drop ceilings throughout. The ceramic tiles and associated bedding and seam grout are suspect for asbestos. These suspect materials observed throughout the bathrooms were noted however not sampled for asbestos laboratory analysis as they are not expected to be impacted by the renovations throughout the remainder of the building.
3.3 LBP SURVEY
CHA collected three paint chip samples throughout Building 1. Samples were collected from substrates such as walls and ceilings that are assumed to be impacted by the renovations. The walls and ceilings throughout were painted white with limited areas of newer blue paint. All samples were analyzed for lead content by weight. Paint chip samples containing lead at concentrations greater than 0.5% are identified by the USEPA and the United States Department of Housing and Urban Development (HUD) as a lead based paint, whereas any measurable amount of lead in paint is enough to trigger the requirements of the OSHA Lead in Construction Standard.
3.4 MERCURY CONTAINING ITEMS INVENTORY
A room by room survey was performed to determine the presence of items that may contain mercury. The survey was visual in nature and did not include testing of materials to determine mercury content. CHA observed digital (non-mercury containing) thermostat controls and switches throughout the subject building, no suspect mercury containing items were observed.
CHA Project No. 23367 Page 5
3.5 PCB LIGHT BALLAST/FLUORESCENT LIGHT TUBE INVENTORY
A visual survey was made to determine whether fluorescent light ballasts contain PCBs and for the presence of fluorescent light tubes within the project areas of the subject building. A representative number of ballasts were inspected throughout the building and CHA observed labeling stating “No PCBs”. Based on of the observed labeling, the ballasts are considered to contain no PCBs.
The fluorescent light tubes are known to contain trace amounts of mercury in each tube. These light tubes were quantified by building area and summarized in Section 4.0 of this report.
4.0 RESULTS
CHA identified 53 suspect asbestos-containing materials during the pre-renovation asbestos survey within Building 1 and a total of 108 individual bulk samples were collected. Of the 53 suspect asbestos-containing materials, two were confirmed positive based on historical sample results and three were confirmed positive through the current sampling and laboratory analysis. These five confirmed asbestos-containing materials are summarized in the table below.
Table 4-1. Confirmed Asbestos-Containing Material Summary Material Locations(s) Estimated Quantity Friability
Thermal System Insulation (pipe insulation)
Steam Tunnel Beneath First Floor Concrete
Slab
750 lf Friable
Mudded Fitting Insulation 100 mudded fittings
9” x 9” Floor Tile Second Floor (multiple rooms)
3,764 sf Non-Friable
Red Floor Tile and Mastic First Floor Medical Administration Suite
1,961 sf Non-Friable sf – square feet lf – linear feet
All of the bulk samples that were collected are summarized in Table A-1. Table A-1 lists each bulk sample, the location from which it was collected, and also provides the analytical result for each sample. Table A-1 is not intended to outline all locations within the building where those materials exist. Table A-2, the Room by Room Inventory, summarizes all suspect materials that were observed. For each suspect material in each room, the asbestos content is provided.
Three paint chip samples were collected from walls and the first floor ceiling within the subject building and analyzed for % lead by weight. Paint chip sample locations and percentages can be
CHA Project No. 23367 Page 6 found in Table A-3. All three of the samples were found to have no lead above the reporting limit of 0.01% by weight for method SW846. These paints are not considered to be lead-based per EPA and HUD guidelines. The lead paint chip analytical report is provided as Appendix C.
5.0 CONCLUSIONS AND RECOMMENDATIONS
Based upon CHA’s review of the analytical results, historical data and observations made during the inspection, the following conclusions and recommendations have been developed.
5.1 CONCLUSIONS
The conclusions presented in this report are based on information gathered in accordance with the Scope of Work defined in this section of the report. The subject building is occupied, thus destructive investigations were not utilized during this inspection. As such, pipe chases and wall cavities may exist which conceal additional suspect asbestos-containing materials not identified as part of this survey.
Five confirmed asbestos-containing materials were identified in Building 1 though laboratory analysis of bulk samples collected during this survey and the review of historical asbestos information.
The three paint chip samples collected from Building 1 were found to have no detectable lead concentrations and therefore pose no management requirements as lead-based paints by USEPA and HUD standards nor does the disturbance of these painted surfaces require and worker protection requirements under OSHA.
CHA observed approximately 405 light tubes on the first floor and 195 light tubes on the second floor.
5.2 RECOMMENDATIONS
Based on the site inspection and analysis of samples, CHA has developed the following recommendations:
Suspect asbestos materials were observed in bathrooms and the recruitment office within Building 1 however these spaces are not currently scheduled to receive renovations. If it is determined that these spaces will be impacted by the renovations, the suspect materials
CHA Project No. 23367 Page 7 observed during this survey should be sampled and analyzed for asbestos prior to completion and submission of bid documents.
Asbestos-insulated pipes were observed within a steam tunnel located beneath the first floor concrete slab. The steam tunnel is entered from beneath the first floor stairwell. It is assumed that enclosed pipe chases and wall cavities exist which conceal asbestos-insulated pipes.
CHA recommends performing destructive investigations to access a representative number of chases to inspect for suspect pipe insulation prior to construction if it is determined that the renovations will impact these chases or that the chases will be utilized for mechanical/electrical/data system routing.
A brick and grout chimney was observed within the mechanical room in Building 1. It was unclear at the time of this survey whether the chimney will be impacted by the renovations therefore the suspect brick, grout, or suspected firebrick were not sampled as part of this survey report. If it determined that this chimney will be impacted by the renovations, these suspect materials should be sampled for asbestos laboratory analysis.
The following rooms or spaces were inaccessible during the survey site work due to security issues: BioMed Office 338, 1st Sargeants Office (340), Comm. Manager’s Office, Telecomm Room (283), first and second Floor SIPRNET Rooms, and the second floor SARC Office. In addition to the inaccessible rooms listed above, it was determined prior to the completion of this survey that the recruitment office suite and all bathrooms were excluded from the planned renovations. All above-mentioned rooms should be inspected if it is determined during the design phase that they will be impacted during renovations.
Any light tubes removed from fixtures should be disposed of as universal waste during the renovation activities.
This inspection report shall not solely serve as an asbestos abatement design document for obtaining bids from abatement contractors. It is recommended that specific abatement design documents be prepared in order to specify procedures and protocols that must be observed in order to ensure that abatement activities are completed in a manner consistent with local, state and federal regulations and requirements.
FIGURES
UP
DN
UP
DN
192 SF
COMMANDER
163 SF
ADMINISTRATOR
157 SF
0FFICE
123 SF
CHIEF NURSE
104 SF
INTERVIEW RM
103 SF
INTERVIEW RM
77 SF
JANITOR
314 SF
PUBLIC HEALTH
OFFICER
116 SF
BIO MED OFFICE
106 SF
1ST SERGEANT
186 SF
SUPPLY ROOM /
OFFICE
93 SF
VEST
430 SF
IMMUNIZATION
AREA
101 SF
IMMUNIZATION RM
57 SF
PROVIDER
57 SF
EXAM
61 SF
EXAM
61 SF
PROVIDER
62 SF
PROVIDER
66 SF
EXAM
65 SF
EXAM
128 SF
FLIGHT MEDICINE
59 SF
DRAWING AREA
68 SF
DRAWING
313 82 SF
DRUG TESTING
312 22 SF
MEN
49 SF
MENS LOCKER
32 SF
WOMEN
81 SF
WOMENS LOCK.
119 SF
LAB
87 SF
EYE EXAM
91 SF
OPTOMETRY/ADMIN
78 SF
ELECTRO -
CARDIOGRAM
75 SF
ELECTRO -
CARDIOGRAM
117 SF
XRAY
30060 SF
DENTAL
61 SF
DENTAL
69 SF
DARK ROOM
166 SF
DENTAL / ADMIN
178 SF
HEARING
297 221 SF
OFFICE
194 SF
OFFICE
140 SF
OFFICE
130 SF
OFFICE
130 SF
OFFICE
123 SF
SIPERNET
121 SF
OFFICE
121 SF
OFFICE
61 SF
JANITOR
119 SF
TELECOM
423 SF
MISSION SUPPORT
RECEPTION
103 SF
DEPUTY
COMMANDER
247 103 SF
CONFERENCE
238 SF
MISSION SUPPORT
COMMANDER
179 SF
INSPECTOR
GENERAL
191 SF
COMMAND CHEIF
153 SF
HUMAN
RESOURCE
21 SF
CL.
12 SF
CL.
241 SF
EXECUTIVE
OFFICER
21 SF
CL.
258 SF
WING RECEPTION
30 SF
CL.
24 SF
CL.
317 SF
WING COMMANDER
237 SF
VICE COMMANDER
189 SF
COMMUNITY
MANAGER
265 242 SF
PUBLIC AFFAIRS
203 SF
PUBLIC AFFAIRS
892 SF
CONFERENCE
ROOM
351 SF
WOMENS
RESTROOM
333 SF
CIVILIAN PAY &
ACCOUNTING
280 SF
MILITARY PAY &
TRAVEL
105 SF
OFFICE
72 SF
STORAGE
335 SF
ACCOUNTING
417 SF
FINANCE
96 SF
BUDGET OFFICER
54 SF
KITCHEN
402 SF
BOILER ROOM
143 SF
COMPTROLLER
WAITING
ROOM
KITCHEN
MEDICAL
SUITE
MEDICAL
ADMINISTRATION
SUITE
FIRST FLOOR CORRIDOR
LOGISTICS SUITE
PAYROLL SUITE
PA
YR
OL
L
VE
ST
IB
UL
E
MEDICAL
RECEPTION MEDICAL SUITE
HALLWAY
MEN'S
BATHROOM
82 SF
OFFICE
308 SF
OFFICE
263 SF
WELLNESS CENTER
107 SF
OFFICE
109 SF
OFFICE
2032 SF
FLIGHT
PERSONNEL
OFFICES
312 SF
SIPERNET
91 SF
STORAGE
177 SF
CHIEF OF
PERSONNEL
132 SF
CIVILIAN
PERSONNEL
140 SF
OFFICE
120 SF
OFFICE
129 SF
OFFICE
388 SF
RECRUITING
OFFICE
23 SF
STORAGE
131 SF
OFFICE
142 SF
RETENTION OFFICE
449 SF
COMPUTERS /
TESTING
786 SF
CORRODOR
Redundant Room
CORRIDOR
80 SF
STAIR
ELEV
39 SF
ELEVATOR
MACHINE ROOM
25 SF
ELECTRICAL ROOM
215 SF
BREAK ROOM /
STORAGE
Redundant Room
STAIR
41 SF
STAIR
825 SF
WING SAFETY
121 SF
OFFICE
136 SF
OFFICE
93 SF
OFFICE
141 SF
LEGAL OFFICE SUITE
178 SF
SARC OFFICE
131 SF
OFFICE
29 SF
CL.
116 SF
WOMENS
65 SF
TOILET ROOM
32 SF
MENS
60 SF
TOILET ROOM
Room
165 SF
EQUAL OPPORTUNITY
75 SF
OFFICE
128 SF
OFFICE
84 SF
OFFICE
APPENDIX A
Asbestos-Containing Material and LBP Tables – Building 1
TABLE A-1
ASBESTOS BULK SAMPLE SUMMARY
Building 1 Stratton National Guard Base
Schenectady, NY
Sample No. Homogenous Material Sample Location % Asbestos
Thermal System Insulation 50% Mudded Fitting Insulation 30%
01A 2' x 4' Ceiling Tile Waiting Room ND 01B 2' x 4' Ceiling Tile Waiting Room ND 02A 2' x 2' Ceiling Tile Waiting Room ND 02B 2' x 2' Ceiling Tile Waiting Room ND 03A 2' x 2' Ceiling Tile (box pattern) First Floor Corridor ND 03B 2' x 2' Ceiling Tile (box pattern) First Floor Corridor ND 04A 4" Black Cove Base Mastic ND 04B 4" Black Cove Base Mastic ND 05A 4" Black Cove Base ND 05B 4" Black Cove Base ND 06A 4" Dark Tan Cove Base Mastic ND 06B 4" Dark Tan Cove Base Mastic ND 07A 4" Dark Tan Cove Base ND 07B 4" Dark Tan Cove Base ND 08A 4" Light Blue Cove Base Mastic ND 08B 4" Light Blue Cove Base Mastic ND 09A 4" Light Blue Cove Base ND 09B 4" Light Blue Cove Base ND 10A 4" Brown Cove Base Mastic ND 10B 4" Brown Cove Base Mastic ND 11A 4" Brown Cove Base ND 11B 4" Brown Cove Base ND 12A 4" Gray Cove Base Mastic ND 12B 4" Gray Cove Base Mastic ND 13A 4" Gray Cove Base ND 13B 4" Gray Cove Base ND 14A 4" Tan Cove Base Mastic ND 14B 4" Tan Cove Base Mastic ND 15A 4" Tan Cove Base ND 15B 4" Tan Cove Base ND 16A 4" Light Gray Cove Base Mastic ND 16B 4" Light Gray Cove Base Mastic ND 17A 4" Light Gray Cove Base ND 17B 4" Light Gray Cove Base ND 18A Blue Carpet Mastic ND 18B Blue Carpet Mastic ND 19A Purple Carpet Mastic ND 19B Purple Carpet Mastic ND 20A Tan Carpet Mastic ND 20B Tan Carpet Mastic ND 21A Brown Carpet Mastic / Leveling Compound ND 21B Brown Carpet Mastic / Leveling Compound ND 22A 12" x 12" Floor Tile - white with black ND 22B 12" x 12" Floor Tile - white with black ND 23A Mastic to 12" x 12" Floor Tile ND 23B Mastic to 12" x 12" Floor Tile ND 24A 12" x 12" Floor Tile - white ND 24B 12" x 12" Floor Tile - white ND 25 Mastic to 12" x 12" Floor Tile - white ND
26A 12" x 12" Floor Tile - tan with brown ND 26B 12" x 12" Floor Tile - tan with brown ND 27A Mastic to 12" x 12" Floor Tile - tan with brown ND 27B Mastic to 12" x 12" Floor Tile - tan with brown ND 28A 12" x 12" Floor Tile - mottled tan ND 28B 12" x 12" Floor Tile - mottled tan ND 29 Mastic to 12" x 12" Floor Tile - mottled tan ND
30A Floor Tile Beneath Mottled Tan 12" x 12" Floor Tile ND 30B Floor Tile Beneath Mottled Tan 12" x 12" Floor Tile ND
31 Mastic to Floor Tile Beneath Mottled Tan 12" x 12" Floor Tile ND
Medical Suite
E.O. Office (Room 242)
Janitor's Room (346)
Logistics Offices
Wellness Center Office (Rm 204)
Legal Office 232
Logistics Office Suite
First Floor Supply Room
Medical Administration Office
Logistics Office Suite
Payroll Office Suite
Historical Asbestos Information - Civil Engineering Technical Services Center (of the Air National Guard) No Sample Numbers
Provided Tunnel at "West Vestibule"
CHA Consulting Inc. (March 16, 2012)
Office 296
Human Resources Office Suite
Flight Personnel Office
Public Affairs Office
CHA Consulting, Inc. ACM Survey
TABLE A-1
ASBESTOS BULK SAMPLE SUMMARY
Building 1 Stratton National Guard Base
Schenectady, NY
Sample No. Homogenous Material Sample Location % Asbestos
32A 9" x 9" Floor Tile Mastic - brown ND 32B 9" x 9" Floor Tile Mastic - brown ND 33A 9" x 9" Floor Tile - brown 5% 33B 9" x 9" Floor Tile - brown NA/PS 34A Red Floor Tile 1.9% 34B Red Floor Tile 1.9% 35 Red Floor Tile Mastic 2.7%
36A Tan Floor Tile <1% 36B Tan Floor Tile <1% 37A Seam Grout to Ceramic Floor Tile ND 37B Seam Grout to Ceramic Floor Tile ND 38A Bedding Grout to Ceramic Floor Tile ND 38B Bedding Grout to Ceramic Floor Tile ND 39A Pink Ceramic Floor Tile ND 39B Pink Ceramic Floor Tile ND 40A Seam Grout to Gray Ceramic Floor Tile ND 40B Seam Grout to Gray Ceramic Floor Tile ND 41A Bedding Grout to Gray Ceramic Floor Tile ND 41B Bedding Grout to Gray Ceramic Floor Tile ND 42A Gray Ceramic Floor Tile ND 42B Gray Ceramic Floor Tile ND 43A Mastic Beneath Gray Ceramic Floor Tile ND 43B Mastic Beneath Gray Ceramic Floor Tile ND 44A Wall Plaster - Skimcoat ND 44B Wall Plaster - Skimcoat ND 44C Wall Plaster - Skimcoat ND 44D Wall Plaster - Skimcoat ND 44E Wall Plaster - Skimcoat ND 45A Wall Plaster - Subcoat ND 45B Wall Plaster - Subcoat ND 45C Wall Plaster - Subcoat ND 45D Wall Plaster - Subcoat ND 45E Wall Plaster - Subcoat ND 46A Sheetrock Waiting Room ND 46B Sheetrock Waiting Room ND 47A Sheetrock Second Floor Office ND 47B Sheetrock Second Floor Office ND 48A Sheetrock First Floor Stairwell ND 48B Sheetrock First Floor Stairwell ND 49A Joint Compound Waiting Room ND 49B Joint Compound Waiting Room ND 50A Joint Compound Second Floor Office ND 50B Joint Compound Second Floor Office ND 51A Joint Compound First Floor Stairwell ND 51B Joint Compound First Floor Stairwell ND 52A Expansion Joint Caulk - gray ND 52B Expansion Joint Caulk - gray ND 53A Exterior Window Caulk - brown ND 53B Exterior Window Caulk - brown ND
ND = No Asbestos Detected
Second Floor Kitchen / Break Room (Rm 226)
Second Floor Kitchen / Break Room (Rm 226)
NA/PS = Not Analyzed / Positive Stop
Exterior of Building
First Floor Corridor
Waiting Room
Second Floor Kitchen / Break Room (Rm 226)
Second Floor Kitchen / Break Room (Rm 226)
Second Floor Kitchen / Break Room (Rm 226)
CHA Consulting, Inc. ACM Survey
TABLE A-2
ROOM BY ROOM INVENTORY
Building 1 Stratton National Guard Base
Schenectady, NY
ROOM NAME SUSPECT MATERIALS
ASBESTOS
CONTENT
FLOORING
(SF) WALLS (SF) CEILINGS (SF)
THERMAL
SYSTEM
INSULATION
MISCELLANEOUS
MATERIAL
(SF/LF)
Exterior Window Frame Caulk ND Exterior Expansion Joint Caulk ND
Boiler Room No Suspect ACM observed Crawlspace Adjacent to
Mechanical Room No Suspect ACM observed
Thermal System Insulation 30% 750 linear feet Mudded Fitting Insulation 50% 100 fittings
Gray Ceramic Floor Tile ND Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND
Ceramic Floor Tile Mastic ND Sheetrock ND
Joint Compound ND 2' x 2' Ceiling Tiles ND
Gray Ceramic Floor Tile ND Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND
Ceramic Floor Tile Mastic ND Sheetrock ND
Joint Compound ND 2' x 4' Ceiling Tiles ND 2' x 2' Ceiling Tiles ND
Gray Cove Base ND Cove Base Mastic ND
12" x 12" Floor Tile - White ND Floor Tile Mastic ND
2' x 2' Ceiling Tiles ND Gray Cove Base ND
Cove Base Mastic ND Sheetrock ND
Joint Compound ND Gray Ceramic Floor Tile ND
Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND
Ceramic Floor Tile Mastic ND Sheetrock ND
Joint Compound ND 2' x 4' Ceiling Tiles ND 2' x 2' Ceiling Tiles ND
Gray Cove Base ND Cove Base Mastic ND
Steam Tunnel Beneath the First Floor Slab
Exterior of the Building
Vestibule (333)
Waiting Area (Adjacent to Vestibule)
Roof Levels Are "Not In Scope"
Medical Suite Hallways
Medical Reception Area
Interior of the Building - First Floor
Building 1 Stratton National Guard Base
Schenectady, NY
ROOM NAME SUSPECT MATERIALS
ASBESTOS
CONTENT
FLOORING
(SF) WALLS (SF) CEILINGS (SF)
THERMAL
SYSTEM
INSULATION
MISCELLANEOUS
MATERIAL
(SF/LF)
12" x 12" Floor Tile - White ND
Floor Tile Mastic ND 2' x 2' Ceiling Tiles ND
Gray Cove Base ND Cove Base Mastic ND
Sheetrock ND Joint Compound ND
2' x 4' Ceiling Tiles ND Blue Carpet Mastic ND 2' x 2' Ceiling Tiles ND
Gray Cove Base ND Cove Base Mastic ND
Sheetrock ND Joint Compound ND
2' x 4' Ceiling Tiles ND Light Gray 2" Ceramic Floor Tile ND
Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND
Ceramic Floor Tile Mastic ND 2' x 2' Ceiling Tiles ND
Sheetrock ND Joint Compound ND
4" Light Pink Ceramic Wall Tile ND Ceramic Wall Tile Grout ND Gray Ceramic Floor Tile ND
Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND
Ceramic Floor Tile Mastic ND Pink Ceramic Floor Tile ND
Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND
Ceramic Floor Tile Mastic ND 2' x 2' Ceiling Tiles ND
Sheetrock ND Joint Compound ND
2' x 4' Ceiling Tiles ND 4" Tan Wall Tile ND Wall Tile Grout ND
4" Gray Cove Base ND Cove Base Mastic ND
Medical Suite of Exam Rooms and Offices
Office 296
Women's Locker Room in Medical Suite
Men's Locker Room in Medical Suite
Building 1 Stratton National Guard Base
Schenectady, NY
ROOM NAME SUSPECT MATERIALS
ASBESTOS
CONTENT
FLOORING
(SF) WALLS (SF) CEILINGS (SF)
THERMAL
SYSTEM
INSULATION
MISCELLANEOUS
MATERIAL
(SF/LF)
Gray Ceramic Floor Tile ND
Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND
Ceramic Floor Tile Mastic ND Tan Mottled 12" x 12" Floor Tile ND
Floor Tile Mastic ND 2' x 2' Ceiling Tiles ND 2' x 4' Ceiling Tiles ND
Sheetrock ND Joint Compound ND
4" Gray Cove Base ND Cove Base Mastic ND
Gray Ceramic Floor Tile ND Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND
Ceramic Floor Tile Mastic ND 2' x 2' Ceiling Tiles ND
Sheetrock ND Joint Compound ND
12" x 12" Floor Tile - White ND Floor Tile Mastic ND
12" x 12" Floor Tile - White and Black ND Underlying Beige Floor Tile ND
Sheetrock ND Joint Compound ND
2' x 2' Ceiling Tiles ND 2' x 4' Ceiling Tiles ND 4" Gray Cove Base ND Cove Base Mastic ND
Blue Carpet Mastic ND 12" x 12" Floor Tile - White and Black ND
Underlying Red Floor Tile 1.9% Red Floor Tile Mastic 2.7%
Underlying Tan Floor Tile <1% Sheetrock ND
Joint Compound ND 2' x 2' Ceiling Tiles ND 2' x 4' Ceiling Tiles ND 4" Tan Cove Base ND Cove Base Mastic ND
4" Dark Gray Cove Base ND Cove Base Mastic ND
Biomed Office (338)
1st Sargeants Office (340)
Medical Administrative Offices 342, 343, 347, 349, 350, 351
Supply Room / Office (324)
Inaccessible
Kitchen
Public Health Officer (341)
Building 1 Stratton National Guard Base
Schenectady, NY
ROOM NAME SUSPECT MATERIALS
ASBESTOS
CONTENT
FLOORING
(SF) WALLS (SF) CEILINGS (SF)
THERMAL
SYSTEM
INSULATION
MISCELLANEOUS
MATERIAL
(SF/LF)
12" x 12" Floor Tile - White and Black ND
Underlying Red Floor Tile 1.9% Red Floor Tile Mastic 2.7%
Underlying Tan Floor Tile <1% Sheetrock ND
Joint Compound ND 2' x 2' Ceiling Tiles ND 2' x 4' Ceiling Tiles ND 4" Gray Cove Base ND Cove Base Mastic ND
Pink and Green Ceramic Floor Tile ND Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND
Ceramic Floor Tile Mastic ND 2' x 2' Ceiling Tiles ND 2' x 4' Ceiling Tiles ND
Sheetrock ND Joint Compound ND
Dark Gray Ceramic Floor Tile ND Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND
Ceramic Floor Tile Mastic ND 2' x 4' Ceiling Tiles ND
Sheetrock ND Joint Compound ND
4" Gray Ceramic Wall Tiles ND Ceramic Tile Grout ND Blue Carpet Mastic ND
Sheetrock ND Joint Compound ND
2' x 2' Ceiling Tiles ND 4" Dark Gray Cove Base ND
Cove Base Mastic ND Blue Carpet Mastic ND
Sheetrock ND Joint Compound ND
2' x 2' Ceiling Tiles ND 4" Dark Gray Cove Base ND
Cove Base Mastic ND Blue Carpet Mastic ND
Sheetrock ND Joint Compound ND
2' x 2' Ceiling Tiles ND 4" Tan Cove Base ND Cove Base Mastic ND
Command Chief Suite
Janitor's Closet (346)
First Floor Corridor
Men's Bathroom
Mission Support Offices
Commander's Office in Mission Support
Building 1 Stratton National Guard Base
Schenectady, NY
ROOM NAME SUSPECT MATERIALS
ASBESTOS
CONTENT
FLOORING
(SF) WALLS (SF) CEILINGS (SF)
THERMAL
SYSTEM
INSULATION
MISCELLANEOUS
MATERIAL
(SF/LF)
Blue Carpet Mastic ND
Sheetrock ND Joint Compound ND
2' x 2' Ceiling Tiles ND 4" Tan Cove Base ND Cove Base Mastic ND Blue Carpet Mastic ND
Sheetrock ND Joint Compound ND
2' x 2' Ceiling Tiles ND
Comm. Manager's Office
Blue Carpet Mastic ND Sheetrock ND
Joint Compound ND 2' x 2' Ceiling Tiles ND 4" Tan Cove Base ND Cove Base Mastic ND Blue Carpet Mastic ND
Sheetrock ND Joint Compound ND
2' x 2' Ceiling Tiles ND 4" Tan Cove Base ND Cove Base Mastic ND
Telecomm Room (283) Inaccessible ND Tan Mottled 12" x 12" Floor Tile ND
Floor Tile Mastic ND 2' x 2' Ceiling Tiles ND
Sheetrock ND Joint Compound ND
4" Tan Ceramic Wall Tile ND Ceramic Wall Tile Grout ND 4" Dark Gray Cove Base ND
Cove Base Mastic ND 12" x 12" Floor Tile - White with Black ND
Floor Tile Mastic ND 4" Light Blue Cove Base ND
Cove Base Mastic ND 2' x 2' Ceiling Tiles ND
Sheetrock ND Joint Compound ND
Logistics Suite
Human Resources Suite (257)
Wing Reception Office
Public Affairs
Wing Conference Room (269)
Janitor's Closet (284)
Inaccessible
Building 1 Stratton National Guard Base
Schenectady, NY
ROOM NAME SUSPECT MATERIALS
ASBESTOS
CONTENT
FLOORING
(SF) WALLS (SF) CEILINGS (SF)
THERMAL
SYSTEM
INSULATION
MISCELLANEOUS
MATERIAL
(SF/LF)
4" Light Blue Cove Base ND
Cove Base Mastic ND 2' x 2' Ceiling Tiles ND
Sheetrock ND Joint Compound ND
Purple Carpet Mastic ND SIPRNET ROOM Inaccessible ND
Brown Carpet Mastic ND 4" Brown Cove Base ND Cove Base Mastic ND 2' x 4' Ceiling Tiles ND
Sheetrock ND Joint Compound ND
Gray Ceramic Floor Tile ND Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND
Ceramic Floor Tile Mastic ND 2' x 4' Ceiling Tiles ND
Sheetrock ND Joint Compound ND
4" Brown Cove Base ND Cove Base Mastic ND
Gray Ceramic Floor Tile ND Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND
Ceramic Floor Tile Mastic ND 2' x 4' Ceiling Tiles ND
Sheetrock ND Joint Compound ND
4" Brown Cove Base ND Cove Base Mastic ND 4" Tan Cove Base ND Cove Base Mastic ND
Pink and Green Ceramic Floor Tile ND Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND
Ceramic Floor Tile Mastic ND 2' x 4' Ceiling Tiles ND
Sheetrock ND Joint Compound ND
Payroll Suite Storage (280)
Main Payroll Vestibule
Logistics Suite Offices
Payroll Suite
Payroll Suite Kitchen (282)
Building 1 Stratton National Guard Base
Schenectady, NY
ROOM NAME SUSPECT MATERIALS
ASBESTOS
CONTENT
FLOORING
(SF) WALLS (SF) CEILINGS (SF)
THERMAL
SYSTEM
INSULATION
MISCELLANEOUS
MATERIAL
(SF/LF)
Light Gray 2" Ceramic Floor Tile ND
Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND
Ceramic Floor Tile Mastic ND 2' x 2' Ceiling Tiles ND
Sheetrock ND Joint Compound ND
4" Light Pink Ceramic Wall Tile ND Ceramic Wall Tile Grout ND
Pink and Green Ceramic Floor Tile ND Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND
Ceramic Floor Tile Mastic ND Brown 9" x 9" Floor Tile 5% 500 9" x 9" Floor Tile Mastic ND
2' x 4' Ceiling Tiles ND 2' x 2' Ceiling Tiles ND
Sheetrock ND Joint Compound ND
4" Brown Cove Base ND Cove Base Mastic ND Tan Carpet Mastic ND
Tan Floor Tile Beneath Carpet ND 2' x 2' Ceiling Tiles ND
Sheetrock ND Joint Compound ND
Tan Floor Tile Beneath Carpet ND 2' x 2' Ceiling Tiles ND
Sheetrock ND Joint Compound ND
Blue Carpet Mastic ND 4" Brown Cove Base ND Cove Base Mastic ND
Tan Mottled 12" x 12" Floor Tile ND Floor Tile Mastic ND
Tan Floor Tile Beneath Mottled 12" x 12" Floor Tile ND
4" Tan Cove Base ND Cove Base Mastic ND
Sheetrock ND Joint Compound ND
2' x 2' Ceiling Tiles ND
Interior of the Building - Second Floor
Corridor 220
Wellness Center Reception
Wellness Center Offices
Legal Office Suite
Women's Restroom (272)
Building 1 Stratton National Guard Base
Schenectady, NY
ROOM NAME SUSPECT MATERIALS
ASBESTOS
CONTENT
FLOORING
(SF) WALLS (SF) CEILINGS (SF)
THERMAL
SYSTEM
INSULATION
MISCELLANEOUS
MATERIAL
(SF/LF)
Brown Carpet Mastic ND
Tan Floor Tile Beneath Carpet ND
4" Tan Cove Base ND Cove Base Mastic ND
Sheetrock ND Joint Compound ND
2' x 2' Ceiling Tiles ND Purple Carpet Mastic ND
Sheetrock ND Joint Compound ND
2' x 2' Ceiling Tiles ND SARC Office Inaccessible ND
4" Tan Cove Base ND Cove Base Mastic ND
Tan 12" x 12" Floor Tile with Brown ND Floor Tile Mastic ND
2' x 2' Ceiling Tiles ND Sheetrock ND
Joint Compound ND Gray Ceramic Floor Tile ND
Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND
Ceramic Floor Tile Mastic ND Sheetrock ND
Joint Compound ND 4" Blue Ceramic Wall Tile ND Ceramic Wall Tile Grout ND
2' x 2' Ceiling Tiles ND Blue Carpet Mastic ND Ceramic Floor Tile ND
Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND
Ceramic Floor Tile Mastic ND Sheetrock ND
Joint Compound ND 2' x 2' Ceiling Tiles ND
4" Brown Cove Base ND Cove Base Mastic ND 4" Tan Cove Base ND Cove Base Mastic ND
Men's Bathroom (239, 240)
Women's Bathroom (237, 238)
Legal Offices
Wing Safety Offices (229)
Equal Opportunity Offices
Building 1 Stratton National Guard Base
Schenectady, NY
ROOM NAME SUSPECT MATERIALS
ASBESTOS
CONTENT
FLOORING
(SF) WALLS (SF) CEILINGS (SF)
THERMAL
SYSTEM
INSULATION
MISCELLANEOUS
MATERIAL
(SF/LF)
Gray Ceramic Floor Tile ND
Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND
Ceramic Floor Tile Mastic ND Sheetrock ND
Joint Compound ND 2' x 2' Ceiling Tiles ND Gray Carpet Mastic ND
Brown 9" x 9" Floor Tile 5% 2,822 9" x 9" Floor Tile Mastic ND
Brown 9" x 9" Floor Tile 5% 215 9" x 9" Floor Tile Mastic ND
Wall Plaster ND Sheetrock ND
Joint Compound ND Blue Carpet Mastic ND
Sheetrock ND Joint Compound ND
2' x 2' Ceiling Tiles ND 4" Light Blue Cove Base ND
Cove Base Mastic ND Sheetrock ND
Joint Compound ND 2' x 2' Ceiling Tiles ND
4" Light Blue Cove Base ND Cove Base Mastic ND
12" x 12" Floor Tile - White with Black ND Floor Tile Mastic ND
4" Tan Cove Base ND Cove Base Mastic ND
4" Brown Cove Base ND Cove Base Mastic ND
Brown 9" x 9" Floor Tile 5% 227 9" x 9" Floor Tile Mastic ND
Sheetrock ND Joint Compound ND
2' x 2' Ceiling Tiles ND 2' x 4' Ceiling Tiles ND
Roof Access Stairwell
(228) No Suspect ACM observed ND
Recruiting Office Suite (215)
Stairwell (222)
Flight Personnel Office (207)
Flight Personnel Break Room (226)
Main Stairwell (227)
TABLE A-3
PAINT CHIP SAMPLE SUMMARY
Building 1 Stratton National Guard Base
Schenectady, NY
Sample No. Paint Chip Description Sample Location % Lead (By Weight)
LBP-01 White Ceiling Paint <0.01% LBP-02 White Wall Paint <0.01% LBP-03 Blue Wall Paint Second Floor Flight Personnel Office <0.01%
0.5% = Lead-Based Paint (EPA and HUD)
First Floor Corridor
CHA Consulting, Inc. LBP Survey
APPENDIX B
Historical Asbestos Information
APPENDIX C
Current Bulk Asbestos Sample Analysis
EMSL Analytical, Inc.
307 West 38th Street, New York, NY 10018 Phone/Fax: (212) 290-0051 / (212) 290-0058 http://www.emsl.com manhattanlab@emsl.com
031208775 CustomerID: CLOU50 CustomerPO:
ProjectID:
EMSL Order:
Attn: Jim Morey
CHA
3 Winners Circle Albany, NY 12205 Received: 03/23/2012 9:31 AM
STRATTON NGB
Fax: (518) 453-4773 Phone: (518) 453-8702 Project:
3/27/2012Analysis Date:
Collected: 3/20/2012
Analyzed Date Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor
Non Asbestos
Test Report:Asbestos Analysis of Bulk Material
01A 031208775-0001
2'X4' CEILING TILE
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Gray
Gray
Glass14.5%
01B 031208775-0002
2'X4' CEILING TILE
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Gray
Gray
Glass16.2%
02A 031208775-0003
2'X2' CEILING TILE
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Gray
Gray
Glass1.9%
02B 031208775-0004
2'X2' CEILING TILE
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Gray
Gray
Glass13.5%
03A 031208775-0005
2'X2' CEILING TILE BOX PATTERN
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Gray
Gray
Glass11.7%
03B 031208775-0006
2'X2' CEILING TILE BOX PATTERN
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Gray
Gray
Glass9.1%
04A 031208775-0007
4" BLACK COVE BASE MASTIC
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Yellow
Yellow
Page 1Test Report NY198w/A-7.21.0 Printed: 3/30/2012 8:44:21 AM
Initial Report From 03/30/2012 08:44:21 http://www.emsl.com mailto:manhattanlab@emsl.com
Phone/Fax: (212) 290-0051 / (212) 290-0058 http://www.emsl.com manhattanlab@emsl.com
031208775 CustomerID: CLOU50 CustomerPO:
ProjectID:
EMSL Order:
Attn: Jim Morey
CHA
3 Winners Circle Albany, NY 12205 Received: 03/23/2012 9:31 AM
STRATTON NGB
Fax: (518) 453-4773 Phone: (518) 453-8702 Project:
3/27/2012Analysis Date:
Collected: 3/20/2012
Analyzed Date Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor
Non Asbestos
Test Report:Asbestos Analysis of Bulk Material
04B 031208775-0008
4" BLACK COVE BASE MASTIC
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Yellow
Yellow
05A 031208775-0009
4" BLACK COVE BASE
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Black
Black
05B 031208775-0010
4" BLACK COVE BASE
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Black
Black
06A 031208775-0011
4" DARK TAN COVE BASE MASTIC
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Yellow
Yellow
06B 031208775-0012
4" DARK TAN COVE BASE MASTIC
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Yellow
Yellow
07A 031208775-0013
4" DARK TAN COVE BASE
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Brown
Brown
07B 031208775-0014
4" DARK TAN COVE BASE
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Brown
Brown
Page 2Test Report NY198w/A-7.21.0 Printed: 3/30/2012 8:44:21 AM
Initial Report From 03/30/2012 08:44:21
Phone/Fax: (212) 290-0051 / (212) 290-0058 http://www.emsl.com manhattanlab@emsl.com
031208775 CustomerID: CLOU50 CustomerPO:
ProjectID:
EMSL Order:
Attn: Jim Morey
CHA
3 Winners Circle Albany, NY 12205 Received: 03/23/2012 9:31 AM
STRATTON NGB
Fax: (518) 453-4773 Phone: (518) 453-8702 Project:
3/27/2012Analysis Date:
Collected: 3/20/2012
Analyzed Date Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor
Non Asbestos
Test Report:Asbestos Analysis of Bulk Material
08A 031208775-0015
4" LIGHT BLUE COVE BASE MASTIC
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Yellow
Yellow
08B 031208775-0016
4" LIGHT BLUE COVE BASE MASTIC
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Yellow
Yellow
09A 031208775-0017
4" LIGHT BLUE COVE BASE
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Blue
Blue
09B 031208775-0018
4" LIGHT BLUE COVE BASE
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Blue
Blue
10A 031208775-0019
4" BROWN COVE BASE MASTIC
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Yellow
Yellow
10B 031208775-0020
4" BROWN COVE BASE MASTIC
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Yellow
Yellow
11A 031208775-0021
4" BROWN COVE BASE
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Brown
Brown
Page 3Test Report NY198w/A-7.21.0 Printed: 3/30/2012 8:44:21 AM
Initial Report From 03/30/2012 08:44:21
Phone/Fax: (212) 290-0051 / (212) 290-0058 http://www.emsl.com manhattanlab@emsl.com
031208775 CustomerID: CLOU50 CustomerPO:
ProjectID:
EMSL Order:
Attn: Jim Morey
CHA
3 Winners Circle Albany, NY 12205 Received: 03/23/2012 9:31 AM
STRATTON NGB
Fax: (518) 453-4773 Phone: (518) 453-8702 Project:
3/27/2012Analysis Date:
Collected: 3/20/2012
Analyzed Date Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor
Non Asbestos
Test Report:Asbestos Analysis of Bulk Material
11B 031208775-0022
4" BROWN COVE BASE
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Brown
Brown
12A 031208775-0023
4" GRAY COVE BASE MASTIC
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Yellow
Yellow
12A 031208775-0024
4" GRAY COVE BASE MASTIC
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Yellow
Yellow
13A 031208775-0025
4" GRAY COVE BASE
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Gray
Gray
13B 031208775-0026
4" GRAY COVE BASE
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Gray
Gray
14A 031208775-0027
4" TAN COVE BASE MASTIC
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Yellow
Yellow
14B 031208775-0028
4" TAN COVE BASE MASTIC
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Yellow
Yellow
Page 4Test Report NY198w/A-7.21.0 Printed: 3/30/2012 8:44:21 AM
Initial Report From 03/30/2012 08:44:21
Phone/Fax: (212) 290-0051 / (212) 290-0058 http://www.emsl.com manhattanlab@emsl.com
031208775 CustomerID: CLOU50 CustomerPO:
ProjectID:
EMSL Order:
Attn: Jim Morey
CHA
3 Winners Circle Albany, NY 12205 Received: 03/23/2012 9:31 AM
STRATTON NGB
Fax: (518) 453-4773 Phone: (518) 453-8702 Project:
3/27/2012Analysis Date:
Collected: 3/20/2012
Analyzed Date Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor
Non Asbestos
Test Report:Asbestos Analysis of Bulk Material
15A 031208775-0029
4" TAN COVE BASE
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Tan
Tan
15B 031208775-0030
4" TAN COVE BASE
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Tan
Tan
16A 031208775-0031
4" LIGHT GRAY COVE BASE MASTIC
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Yellow
Yellow
16B 031208775-0032
4" LIGHT GRAY COVE BASE MASTIC
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Yellow
Yellow
17A 031208775-0033
4" LIGHT GRAY COVE BASE
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Gray
Gray
17B 031208775-0034
4" LIGHT GRAY COVE BASE
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Gray
Gray
18A 031208775-0035
BLUE CARPET MASTIC
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Yellow
Yellow
Page 5Test Report NY198w/A-7.21.0 Printed: 3/30/2012 8:44:21 AM
Initial Report From 03/30/2012 08:44:21
Phone/Fax: (212) 290-0051 / (212) 290-0058 http://www.emsl.com manhattanlab@emsl.com
031208775 CustomerID: CLOU50 CustomerPO:
ProjectID:
EMSL Order:
Attn: Jim Morey
CHA
3 Winners Circle Albany, NY 12205 Received: 03/23/2012 9:31 AM
STRATTON NGB
Fax: (518) 453-4773 Phone: (518) 453-8702 Project:
3/27/2012Analysis Date:
Collected: 3/20/2012
Analyzed Date Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor
Non Asbestos
Test Report:Asbestos Analysis of Bulk Material
18B 031208775-0036
BLUE CARPET MASTIC
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Yellow
Yellow
19A 031208775-0037
PURPLE CARPET MASTIC
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Yellow
Yellow
19B 031208775-0038
PURPLE CARPET MASTIC
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Yellow
Yellow
20A 031208775-0039
TAN CARPET MASTIC
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Yellow
Yellow
20B 031208775-0040
TAN CARPET MASTIC
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Yellow
Yellow
21A 031208775-0041
BROWN CARPET MASTIC/LEVELING
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Yellow
Yellow Fibrous (other)<1%
21B 031208775-0042
BROWN CARPET MASTIC/LEVELING
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
Yellow
Yellow
Page 6Test Report NY198w/A-7.21.0 Printed: 3/30/2012 8:44:21 AM
Initial Report From 03/30/2012 08:44:21
Phone/Fax: (212) 290-0051 / (212) 290-0058 http://www.emsl.com manhattanlab@emsl.com
031208775 CustomerID: CLOU50 CustomerPO:
ProjectID:
EMSL Order:
Attn: Jim Morey
CHA
3 Winners Circle Albany, NY 12205 Received: 03/23/2012 9:31 AM
STRATTON NGB
Fax: (518) 453-4773 Phone: (518) 453-8702 Project:
3/27/2012Analysis Date:
Collected: 3/20/2012
Analyzed Date Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor
Non Asbestos
Test Report:Asbestos Analysis of Bulk Material
22A 031208775-0043
12"X12" FLOOR TILE (WHITE W./ BLACK)
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
White
White
22B 031208775-0044
12"X12" FLOOR TILE (WHITE W./ BLACK)
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconclusive: None Detected
None Detected
White
White
23A 031208775-0045
MASTIC TO 12"X12" FLOOR TILE
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
3/25/2012
3/27/2012
Not Analyzed
N/A
N/A
Inconcl…
This is the start of the file's text. The full file is on GovTribe.