Addendum_1_Attachement_Pre-Renovation_Hazardous_Materials_Survey_Report 1 .pdf

PDF 7 MB Posted

Attached to
IDIQ MATOC CONTRACT FOR 109TH AIRLIFT WING
Solicitation number
W912PQ15R0006
Issued by

About this file

Pre-Renovation Hazardous Survey Report

View the file

Other files

File Type Posted
AMEND_2.pdf PDF
Exhibit_B.docx DOCX document
2015_05_20_-_Bldg_1_-_Addendum_2_final.pdf PDF
Addendum_2_MATOC_Site_Visit_Attendance_List.pdf PDF
ADDENDUM_1_-_MATOC.docx DOCX document
2nd_site_visit.docx DOCX document
Pre-prosoal_confence_and_site_visit_attendance.pdf PDF
MATOC_PRE-PROPOSAL_MTG.pptx PPTX presentation
Pre-Performance_Conference_ _Site_Visit_Minutes.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pre-Renovation Hazardous Materials Survey Report

Building 1

Stratton National Guard Base Schenectady, New York

CHA Project Number: 23367.1000.31000

Prepared for:

Stratton Air National Guard

109 AW-NY Air National Guard Schenectady, New York 12302

Prepared by:

III Winners Circle Albany, New York 12205

Phone: (518) 453-4500

April 12, 2012

V:\Projects\ANY\K2\23367\Reports\Hazmat Report\Hazardous Material Survey Report.doc

Air National Guard Building 1 CHA Project No. 23367 Page i

QUALIFICATIONS AND CERTIFICATION STATEMENT

This Pre-Renovation Hazardous Materials Survey Report was compiled by a qualified environmental scientist who is also a NYS-certified asbestos inspector employed by CHA.

This report has been prepared expressly for the use of the Air National Guard. No other parties are entitled to rely upon this report unless our express written consent is first obtained. All conclusions drawn were based on CHA’s review of available historical data, field inspection and analytical results from sampling performed during the course of this project. Recommendations are submitted based on CHA's knowledge, experience, and professional judgment.

Inspection and Report Completed By:

James Morey Scientist III

Report Reviewed By:

Seth H. Fowler, CHMM

Associate

CHA Project No. 23367 Page ii

TABLE OF CONTENTS

1.0 INTRODUCTION

2.0 SCOPE OF WORK

2.1 Asbestos-Containing Materials Survey

2.2 Lead-Based Paint Survey

2.3 Mercury Containing Item Inventory

2.4 PCB Light Ballast/Fluorescent Light Tubes Inventory

2.5 Limitations

3.0 HAZARDOUS MATERIALS SURVEY

3.1 Record Review

3.2 ACM Survey

3.3 LBP Survey

3.4 Mercury Containing Items Inventory

3.5 PCB Light Ballast/Fluorescent Light Tube Inventory

4.0 RESULTS

5.0 CONCLUSIONS AND RECOMMENDATIONS

5.1 Conclusions

5.2 Recommendations

LIST OF TABLES

Table 4-1 Confirmed Asbestos-Containing Materials Summary

LIST OF FIGURES

Figure 1 First Floor Sample Location Plan Figure 2 Second Floor Sample Location Plan

LIST OF APPENDICES

Appendix A Asbestos-Containing Material and LBP Tables – Building 1 Appendix B Historical Asbestos Information Appendix C Current Bulk Asbestos Sample Analysis Appendix D Paint Chip Sample Analysis Appendix E Personnel and Laboratory Licenses

CHA Project No. 23367 Page 1

1.0 INTRODUCTION

CHA was retained by the Stratton Air National Guard to complete a pre-renovation hazardous materials survey of all accessible interior portions and limited exterior portions of Building 1 on the Stratton National Guard Base (NGB) located in Schenectady, New York. This survey was performed to support the renovations, currently in development, which will impact floors, walls, ceilings and mechanical systems throughout the subject building.

This survey report consists of five sections, including this Introduction. Section 2.0 presents the Scope of Work, which outlines the parameters by which this project was performed and the limitations that were encountered. Section 3.0 – Hazardous Materials Survey, details the findings of the pre-renovation asbestos building inspection, lead-based paint chip sampling, mercury-containing item inventory, and PCB-containing equipment inventory. Section 4.0 presents a brief overview of the inspection results while Section 5.0 presents CHA’s conclusions and recommendations regarding the status of the building that was inspected.

2.0 SCOPE OF WORK

2.1 ASBESTOS-CONTAINING MATERIALS SURVEY

The pre-renovation asbestos-containing material (ACM) survey was performed according to the scope of work provided below. All work has been completed in accordance with federal, state, and local regulations.

CHA provided a New York State Department of Labor-certified asbestos building inspector responsible for the identification and assessment of the condition, location and quantity of suspect asbestos-containing materials associated with the accessible areas within the subject building scheduled to be renovated. The inspector collected bulk samples of identified suspect asbestos-containing material following the protocols referenced in 40 CFR Part 763.86 Subpart E (AHERA).

All bulk samples were analyzed at an accredited laboratory licensed by the New York State Department of Health (NYSDOH) Environmental Laboratory Program (ELAP) as well as the National Voluntary Laboratory Accreditation Program (NVLAP) for the analysis of asbestos bulk samples.

2.2 LEAD-BASED PAINT SURVEY

The investigation was conducted to identify Lead-Based Paint (LBP) surfaces and/or sub layers

CHA Project No. 23367 Page 2 associated with Building 1. Paint chip samples were collected at random locations within subject areas and all samples were analyzed for percent lead content using Method 6010B for percent lead in paint.

It should be noted that the lead-based paint survey is intended to assess the need for the safe and proper management of painted surfaces during the renovations throughout the building. The survey and the resultant sample data are not meant to assess building occupant exposure or to represent a risk assessment.

2.3 MERCURY CONTAINING ITEM INVENTORY

A room by room survey was performed to determine the presence of items that may contain mercury. The survey was visual in nature and did not include testing of materials to determine mercury content. The visual survey included items such as thermostats and switches.

2.4 PCB LIGHT BALLAST/FLUORESCENT LIGHT TUBE INVENTORY

A visual survey was made to determine whether fluorescent light ballasts contain PCBs and for the presence of fluorescent light tubes within the project areas of the subject building. Determination of PCBs was made by visually checking a representative number of ballasts. If the ballasts were labeled as containing “No PCBs”, then they were considered to contain no PCBs, however, if they did not have a label stating “No PCBs” they are assumed to contain PCBs.

2.5 LIMITATIONS

The renovations planned throughout Building 1 are still in the schematic design phase thus CHA attempted to inspect all interior portions of the building. Based on conversations with the project team, the bathrooms and recruitment office suite have been recently renovated and were considered “out of scope” for this pre-renovation survey. Based on this, CHA recorded the suspect materials observed in these spaces however no bulk samples were collected. The roof systems were excluded from the scope of work as the renovations are not expected to impact roof levels. See Figures 1 and 2 for the inspected portions of the building and bulk sample locations.

CHA Project No. 23367 Page 3

3.0 HAZARDOUS MATERIALS SURVEY

CHA’s background research and field observations during the site inspection with regard to suspect hazardous building materials associated with the subject building at Stratton NGB are discussed below.

3.1 RECORD REVIEW

The Air National Guard Readiness Center (ANGRC) Civil Engineering Unit Technical Services Center’s Asbestos Management Team completed an Asbestos Management Report for the Stratton National Guard Base in February/March 1996. This management plan was provided to CHA prior to the survey fieldwork and was referenced during bulk sample collection.

Based on this historical documentation, CHA determined that the thermal system insulation on heating and plumbing lines is asbestos-containing and therefore collected no additional samples of pipe insulation. Four 12” x 12” floor tiles and their respective mastics were identified as suspect for asbestos during the asbestos management plan and single samples were collected for each material.

Since the completion of the management plan in 1996, the United States Environmental Protection Agency (EPA) and New York State Department of Health clarified their bulk sample collection criteria with regard to number of acceptable samples per material and analytical methodology used for laboratory analysis. Based on the updated interpretation of both the state and federal asbestos regulations, CHA collected additional samples of floor tiles and their respective mastics.

3.2 ACM SURVEY

CHA performed a pre-renovation asbestos-containing material survey of accessible interior and exterior portions of Building 1 that will be impacted by the upcoming renovations, with exception of those areas discussed in Section 2.5. The renovations consist of the reconfiguration of interior spaces, mechanical and electrical upgrades, and the creation of new office suites.

Building 1 is a two-story brick building which was built in 1951 and consists of first floor medical and dental suites, administrative offices, conference rooms, break rooms, and bathrooms. The exterior elevation of the building was observed to have a single vintage of windows and doors sealed with one type of suspect frame caulk. A vertical expansion joint was observed extending from grade level to roof level and had a caulk filler which is also suspect for asbestos. The window and expansion joint caulk were quantified and sampled for asbestos laboratory analysis.

CHA Project No. 23367 Page 4

The mechanical room and adjoining crawlspace (accessible from the exterior of the building) were inspected for suspect asbestos-containing materials. CHA observed non-suspect fiberglass insulation and PVC fittings throughout both spaces and no suspect asbestos insulation debris was observed on the dirt floor throughout the crawlspace. Steam tunnel access was located below the stairs on the first floor. Previously-confirmed asbestos-containing thermal system insulation and mudded fitting insulation was observed on piping running within this tunnel. It is assumed that this tunnel runs the length of the building and branches to connect with the boiler room and crawlspace entrance.

The first and second floors consist of medical and dental suites of examination rooms, offices, bathrooms, and storage rooms, staff offices, and utility rooms and are very uniform in building materials. The floors are a combination of suspect 9” x 9” and 12” x 12” floor tile (and mastic), 4” cove base (and mastic) and carpeting with limited areas of multiple layers of floor tile. The walls throughout the building are suspect sheetrock and joint compound with older suspect wall plaster behind the sheetrock. The ceilings are a combination of suspect 2’ x 2’ and 2’ x 4’ drop ceiling tiles.

The bathrooms have ceramic tiled floors and walls with drop ceilings throughout. The ceramic tiles and associated bedding and seam grout are suspect for asbestos. These suspect materials observed throughout the bathrooms were noted however not sampled for asbestos laboratory analysis as they are not expected to be impacted by the renovations throughout the remainder of the building.

3.3 LBP SURVEY

CHA collected three paint chip samples throughout Building 1. Samples were collected from substrates such as walls and ceilings that are assumed to be impacted by the renovations. The walls and ceilings throughout were painted white with limited areas of newer blue paint. All samples were analyzed for lead content by weight. Paint chip samples containing lead at concentrations greater than 0.5% are identified by the USEPA and the United States Department of Housing and Urban Development (HUD) as a lead based paint, whereas any measurable amount of lead in paint is enough to trigger the requirements of the OSHA Lead in Construction Standard.

3.4 MERCURY CONTAINING ITEMS INVENTORY

A room by room survey was performed to determine the presence of items that may contain mercury. The survey was visual in nature and did not include testing of materials to determine mercury content. CHA observed digital (non-mercury containing) thermostat controls and switches throughout the subject building, no suspect mercury containing items were observed.

CHA Project No. 23367 Page 5

3.5 PCB LIGHT BALLAST/FLUORESCENT LIGHT TUBE INVENTORY

A visual survey was made to determine whether fluorescent light ballasts contain PCBs and for the presence of fluorescent light tubes within the project areas of the subject building. A representative number of ballasts were inspected throughout the building and CHA observed labeling stating “No PCBs”. Based on of the observed labeling, the ballasts are considered to contain no PCBs.

The fluorescent light tubes are known to contain trace amounts of mercury in each tube. These light tubes were quantified by building area and summarized in Section 4.0 of this report.

4.0 RESULTS

CHA identified 53 suspect asbestos-containing materials during the pre-renovation asbestos survey within Building 1 and a total of 108 individual bulk samples were collected. Of the 53 suspect asbestos-containing materials, two were confirmed positive based on historical sample results and three were confirmed positive through the current sampling and laboratory analysis. These five confirmed asbestos-containing materials are summarized in the table below.

Table 4-1. Confirmed Asbestos-Containing Material Summary Material Locations(s) Estimated Quantity Friability

Thermal System Insulation (pipe insulation)

Steam Tunnel Beneath First Floor Concrete

Slab

750 lf Friable

Mudded Fitting Insulation 100 mudded fittings

9” x 9” Floor Tile Second Floor (multiple rooms)

3,764 sf Non-Friable

Red Floor Tile and Mastic First Floor Medical Administration Suite

1,961 sf Non-Friable sf – square feet lf – linear feet

All of the bulk samples that were collected are summarized in Table A-1. Table A-1 lists each bulk sample, the location from which it was collected, and also provides the analytical result for each sample. Table A-1 is not intended to outline all locations within the building where those materials exist. Table A-2, the Room by Room Inventory, summarizes all suspect materials that were observed. For each suspect material in each room, the asbestos content is provided.

Three paint chip samples were collected from walls and the first floor ceiling within the subject building and analyzed for % lead by weight. Paint chip sample locations and percentages can be

CHA Project No. 23367 Page 6 found in Table A-3. All three of the samples were found to have no lead above the reporting limit of 0.01% by weight for method SW846. These paints are not considered to be lead-based per EPA and HUD guidelines. The lead paint chip analytical report is provided as Appendix C.

5.0 CONCLUSIONS AND RECOMMENDATIONS

Based upon CHA’s review of the analytical results, historical data and observations made during the inspection, the following conclusions and recommendations have been developed.

5.1 CONCLUSIONS

The conclusions presented in this report are based on information gathered in accordance with the Scope of Work defined in this section of the report. The subject building is occupied, thus destructive investigations were not utilized during this inspection. As such, pipe chases and wall cavities may exist which conceal additional suspect asbestos-containing materials not identified as part of this survey.

Five confirmed asbestos-containing materials were identified in Building 1 though laboratory analysis of bulk samples collected during this survey and the review of historical asbestos information.

The three paint chip samples collected from Building 1 were found to have no detectable lead concentrations and therefore pose no management requirements as lead-based paints by USEPA and HUD standards nor does the disturbance of these painted surfaces require and worker protection requirements under OSHA.

CHA observed approximately 405 light tubes on the first floor and 195 light tubes on the second floor.

5.2 RECOMMENDATIONS

Based on the site inspection and analysis of samples, CHA has developed the following recommendations:

Suspect asbestos materials were observed in bathrooms and the recruitment office within Building 1 however these spaces are not currently scheduled to receive renovations. If it is determined that these spaces will be impacted by the renovations, the suspect materials

CHA Project No. 23367 Page 7 observed during this survey should be sampled and analyzed for asbestos prior to completion and submission of bid documents.

Asbestos-insulated pipes were observed within a steam tunnel located beneath the first floor concrete slab. The steam tunnel is entered from beneath the first floor stairwell. It is assumed that enclosed pipe chases and wall cavities exist which conceal asbestos-insulated pipes.

CHA recommends performing destructive investigations to access a representative number of chases to inspect for suspect pipe insulation prior to construction if it is determined that the renovations will impact these chases or that the chases will be utilized for mechanical/electrical/data system routing.

A brick and grout chimney was observed within the mechanical room in Building 1. It was unclear at the time of this survey whether the chimney will be impacted by the renovations therefore the suspect brick, grout, or suspected firebrick were not sampled as part of this survey report. If it determined that this chimney will be impacted by the renovations, these suspect materials should be sampled for asbestos laboratory analysis.

The following rooms or spaces were inaccessible during the survey site work due to security issues: BioMed Office 338, 1st Sargeants Office (340), Comm. Manager’s Office, Telecomm Room (283), first and second Floor SIPRNET Rooms, and the second floor SARC Office. In addition to the inaccessible rooms listed above, it was determined prior to the completion of this survey that the recruitment office suite and all bathrooms were excluded from the planned renovations. All above-mentioned rooms should be inspected if it is determined during the design phase that they will be impacted during renovations.

Any light tubes removed from fixtures should be disposed of as universal waste during the renovation activities.

This inspection report shall not solely serve as an asbestos abatement design document for obtaining bids from abatement contractors. It is recommended that specific abatement design documents be prepared in order to specify procedures and protocols that must be observed in order to ensure that abatement activities are completed in a manner consistent with local, state and federal regulations and requirements.

FIGURES

UP

DN

UP

DN

192 SF

COMMANDER

163 SF

ADMINISTRATOR

157 SF

0FFICE

123 SF

CHIEF NURSE

104 SF

INTERVIEW RM

103 SF

INTERVIEW RM

77 SF

JANITOR

314 SF

PUBLIC HEALTH

OFFICER

116 SF

BIO MED OFFICE

106 SF

1ST SERGEANT

186 SF

SUPPLY ROOM /

OFFICE

93 SF

VEST

430 SF

IMMUNIZATION

AREA

101 SF

IMMUNIZATION RM

57 SF

PROVIDER

57 SF

EXAM

61 SF

EXAM

61 SF

PROVIDER

62 SF

PROVIDER

66 SF

EXAM

65 SF

EXAM

128 SF

FLIGHT MEDICINE

59 SF

DRAWING AREA

68 SF

DRAWING

313 82 SF

DRUG TESTING

312 22 SF

MEN

49 SF

MENS LOCKER

32 SF

WOMEN

81 SF

WOMENS LOCK.

119 SF

LAB

87 SF

EYE EXAM

91 SF

OPTOMETRY/ADMIN

78 SF

ELECTRO -

CARDIOGRAM

75 SF

ELECTRO -

CARDIOGRAM

117 SF

XRAY

30060 SF

DENTAL

61 SF

DENTAL

69 SF

DARK ROOM

166 SF

DENTAL / ADMIN

178 SF

HEARING

297 221 SF

OFFICE

194 SF

OFFICE

140 SF

OFFICE

130 SF

OFFICE

130 SF

OFFICE

123 SF

SIPERNET

121 SF

OFFICE

121 SF

OFFICE

61 SF

JANITOR

119 SF

TELECOM

423 SF

MISSION SUPPORT

RECEPTION

103 SF

DEPUTY

COMMANDER

247 103 SF

CONFERENCE

238 SF

MISSION SUPPORT

COMMANDER

179 SF

INSPECTOR

GENERAL

191 SF

COMMAND CHEIF

153 SF

HUMAN

RESOURCE

21 SF

CL.

12 SF

CL.

241 SF

EXECUTIVE

OFFICER

21 SF

CL.

258 SF

WING RECEPTION

30 SF

CL.

24 SF

CL.

317 SF

WING COMMANDER

237 SF

VICE COMMANDER

189 SF

COMMUNITY

MANAGER

265 242 SF

PUBLIC AFFAIRS

203 SF

PUBLIC AFFAIRS

892 SF

CONFERENCE

ROOM

351 SF

WOMENS

RESTROOM

333 SF

CIVILIAN PAY &

ACCOUNTING

280 SF

MILITARY PAY &

TRAVEL

105 SF

OFFICE

72 SF

STORAGE

335 SF

ACCOUNTING

417 SF

FINANCE

96 SF

BUDGET OFFICER

54 SF

KITCHEN

402 SF

BOILER ROOM

143 SF

COMPTROLLER

WAITING

ROOM

KITCHEN

MEDICAL

SUITE

MEDICAL

ADMINISTRATION

SUITE

FIRST FLOOR CORRIDOR

LOGISTICS SUITE

PAYROLL SUITE

PA

YR

OL

L

VE

ST

IB

UL

E

MEDICAL

RECEPTION MEDICAL SUITE

HALLWAY

MEN'S

BATHROOM

82 SF

OFFICE

308 SF

OFFICE

263 SF

WELLNESS CENTER

107 SF

OFFICE

109 SF

OFFICE

2032 SF

FLIGHT

PERSONNEL

OFFICES

312 SF

SIPERNET

91 SF

STORAGE

177 SF

CHIEF OF

PERSONNEL

132 SF

CIVILIAN

PERSONNEL

140 SF

OFFICE

120 SF

OFFICE

129 SF

OFFICE

388 SF

RECRUITING

OFFICE

23 SF

STORAGE

131 SF

OFFICE

142 SF

RETENTION OFFICE

449 SF

COMPUTERS /

TESTING

786 SF

CORRODOR

Redundant Room

CORRIDOR

80 SF

STAIR

ELEV

39 SF

ELEVATOR

MACHINE ROOM

25 SF

ELECTRICAL ROOM

215 SF

BREAK ROOM /

STORAGE

Redundant Room

STAIR

41 SF

STAIR

825 SF

WING SAFETY

121 SF

OFFICE

136 SF

OFFICE

93 SF

OFFICE

141 SF

LEGAL OFFICE SUITE

178 SF

SARC OFFICE

131 SF

OFFICE

29 SF

CL.

116 SF

WOMENS

65 SF

TOILET ROOM

32 SF

MENS

60 SF

TOILET ROOM

Room

165 SF

EQUAL OPPORTUNITY

75 SF

OFFICE

128 SF

OFFICE

84 SF

OFFICE

APPENDIX A

Asbestos-Containing Material and LBP Tables – Building 1

TABLE A-1

ASBESTOS BULK SAMPLE SUMMARY

Building 1 Stratton National Guard Base

Schenectady, NY

Sample No. Homogenous Material Sample Location % Asbestos

Thermal System Insulation 50% Mudded Fitting Insulation 30%

01A 2' x 4' Ceiling Tile Waiting Room ND 01B 2' x 4' Ceiling Tile Waiting Room ND 02A 2' x 2' Ceiling Tile Waiting Room ND 02B 2' x 2' Ceiling Tile Waiting Room ND 03A 2' x 2' Ceiling Tile (box pattern) First Floor Corridor ND 03B 2' x 2' Ceiling Tile (box pattern) First Floor Corridor ND 04A 4" Black Cove Base Mastic ND 04B 4" Black Cove Base Mastic ND 05A 4" Black Cove Base ND 05B 4" Black Cove Base ND 06A 4" Dark Tan Cove Base Mastic ND 06B 4" Dark Tan Cove Base Mastic ND 07A 4" Dark Tan Cove Base ND 07B 4" Dark Tan Cove Base ND 08A 4" Light Blue Cove Base Mastic ND 08B 4" Light Blue Cove Base Mastic ND 09A 4" Light Blue Cove Base ND 09B 4" Light Blue Cove Base ND 10A 4" Brown Cove Base Mastic ND 10B 4" Brown Cove Base Mastic ND 11A 4" Brown Cove Base ND 11B 4" Brown Cove Base ND 12A 4" Gray Cove Base Mastic ND 12B 4" Gray Cove Base Mastic ND 13A 4" Gray Cove Base ND 13B 4" Gray Cove Base ND 14A 4" Tan Cove Base Mastic ND 14B 4" Tan Cove Base Mastic ND 15A 4" Tan Cove Base ND 15B 4" Tan Cove Base ND 16A 4" Light Gray Cove Base Mastic ND 16B 4" Light Gray Cove Base Mastic ND 17A 4" Light Gray Cove Base ND 17B 4" Light Gray Cove Base ND 18A Blue Carpet Mastic ND 18B Blue Carpet Mastic ND 19A Purple Carpet Mastic ND 19B Purple Carpet Mastic ND 20A Tan Carpet Mastic ND 20B Tan Carpet Mastic ND 21A Brown Carpet Mastic / Leveling Compound ND 21B Brown Carpet Mastic / Leveling Compound ND 22A 12" x 12" Floor Tile - white with black ND 22B 12" x 12" Floor Tile - white with black ND 23A Mastic to 12" x 12" Floor Tile ND 23B Mastic to 12" x 12" Floor Tile ND 24A 12" x 12" Floor Tile - white ND 24B 12" x 12" Floor Tile - white ND 25 Mastic to 12" x 12" Floor Tile - white ND

26A 12" x 12" Floor Tile - tan with brown ND 26B 12" x 12" Floor Tile - tan with brown ND 27A Mastic to 12" x 12" Floor Tile - tan with brown ND 27B Mastic to 12" x 12" Floor Tile - tan with brown ND 28A 12" x 12" Floor Tile - mottled tan ND 28B 12" x 12" Floor Tile - mottled tan ND 29 Mastic to 12" x 12" Floor Tile - mottled tan ND

30A Floor Tile Beneath Mottled Tan 12" x 12" Floor Tile ND 30B Floor Tile Beneath Mottled Tan 12" x 12" Floor Tile ND

31 Mastic to Floor Tile Beneath Mottled Tan 12" x 12" Floor Tile ND

Medical Suite

E.O. Office (Room 242)

Janitor's Room (346)

Logistics Offices

Wellness Center Office (Rm 204)

Legal Office 232

Logistics Office Suite

First Floor Supply Room

Medical Administration Office

Logistics Office Suite

Payroll Office Suite

Historical Asbestos Information - Civil Engineering Technical Services Center (of the Air National Guard) No Sample Numbers

Provided Tunnel at "West Vestibule"

CHA Consulting Inc. (March 16, 2012)

Office 296

Human Resources Office Suite

Flight Personnel Office

Public Affairs Office

CHA Consulting, Inc. ACM Survey

TABLE A-1

ASBESTOS BULK SAMPLE SUMMARY

Building 1 Stratton National Guard Base

Schenectady, NY

Sample No. Homogenous Material Sample Location % Asbestos

32A 9" x 9" Floor Tile Mastic - brown ND 32B 9" x 9" Floor Tile Mastic - brown ND 33A 9" x 9" Floor Tile - brown 5% 33B 9" x 9" Floor Tile - brown NA/PS 34A Red Floor Tile 1.9% 34B Red Floor Tile 1.9% 35 Red Floor Tile Mastic 2.7%

36A Tan Floor Tile <1% 36B Tan Floor Tile <1% 37A Seam Grout to Ceramic Floor Tile ND 37B Seam Grout to Ceramic Floor Tile ND 38A Bedding Grout to Ceramic Floor Tile ND 38B Bedding Grout to Ceramic Floor Tile ND 39A Pink Ceramic Floor Tile ND 39B Pink Ceramic Floor Tile ND 40A Seam Grout to Gray Ceramic Floor Tile ND 40B Seam Grout to Gray Ceramic Floor Tile ND 41A Bedding Grout to Gray Ceramic Floor Tile ND 41B Bedding Grout to Gray Ceramic Floor Tile ND 42A Gray Ceramic Floor Tile ND 42B Gray Ceramic Floor Tile ND 43A Mastic Beneath Gray Ceramic Floor Tile ND 43B Mastic Beneath Gray Ceramic Floor Tile ND 44A Wall Plaster - Skimcoat ND 44B Wall Plaster - Skimcoat ND 44C Wall Plaster - Skimcoat ND 44D Wall Plaster - Skimcoat ND 44E Wall Plaster - Skimcoat ND 45A Wall Plaster - Subcoat ND 45B Wall Plaster - Subcoat ND 45C Wall Plaster - Subcoat ND 45D Wall Plaster - Subcoat ND 45E Wall Plaster - Subcoat ND 46A Sheetrock Waiting Room ND 46B Sheetrock Waiting Room ND 47A Sheetrock Second Floor Office ND 47B Sheetrock Second Floor Office ND 48A Sheetrock First Floor Stairwell ND 48B Sheetrock First Floor Stairwell ND 49A Joint Compound Waiting Room ND 49B Joint Compound Waiting Room ND 50A Joint Compound Second Floor Office ND 50B Joint Compound Second Floor Office ND 51A Joint Compound First Floor Stairwell ND 51B Joint Compound First Floor Stairwell ND 52A Expansion Joint Caulk - gray ND 52B Expansion Joint Caulk - gray ND 53A Exterior Window Caulk - brown ND 53B Exterior Window Caulk - brown ND

ND = No Asbestos Detected

Second Floor Kitchen / Break Room (Rm 226)

Second Floor Kitchen / Break Room (Rm 226)

NA/PS = Not Analyzed / Positive Stop

Exterior of Building

First Floor Corridor

Waiting Room

Second Floor Kitchen / Break Room (Rm 226)

Second Floor Kitchen / Break Room (Rm 226)

Second Floor Kitchen / Break Room (Rm 226)

CHA Consulting, Inc. ACM Survey

TABLE A-2

ROOM BY ROOM INVENTORY

Building 1 Stratton National Guard Base

Schenectady, NY

ROOM NAME SUSPECT MATERIALS

ASBESTOS

CONTENT

FLOORING

(SF) WALLS (SF) CEILINGS (SF)

THERMAL

SYSTEM

INSULATION

MISCELLANEOUS

MATERIAL

(SF/LF)

Exterior Window Frame Caulk ND Exterior Expansion Joint Caulk ND

Boiler Room No Suspect ACM observed Crawlspace Adjacent to

Mechanical Room No Suspect ACM observed

Thermal System Insulation 30% 750 linear feet Mudded Fitting Insulation 50% 100 fittings

Gray Ceramic Floor Tile ND Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND

Ceramic Floor Tile Mastic ND Sheetrock ND

Joint Compound ND 2' x 2' Ceiling Tiles ND

Gray Ceramic Floor Tile ND Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND

Ceramic Floor Tile Mastic ND Sheetrock ND

Joint Compound ND 2' x 4' Ceiling Tiles ND 2' x 2' Ceiling Tiles ND

Gray Cove Base ND Cove Base Mastic ND

12" x 12" Floor Tile - White ND Floor Tile Mastic ND

2' x 2' Ceiling Tiles ND Gray Cove Base ND

Cove Base Mastic ND Sheetrock ND

Joint Compound ND Gray Ceramic Floor Tile ND

Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND

Ceramic Floor Tile Mastic ND Sheetrock ND

Joint Compound ND 2' x 4' Ceiling Tiles ND 2' x 2' Ceiling Tiles ND

Gray Cove Base ND Cove Base Mastic ND

Steam Tunnel Beneath the First Floor Slab

Exterior of the Building

Vestibule (333)

Waiting Area (Adjacent to Vestibule)

Roof Levels Are "Not In Scope"

Medical Suite Hallways

Medical Reception Area

Interior of the Building - First Floor

Building 1 Stratton National Guard Base

Schenectady, NY

ROOM NAME SUSPECT MATERIALS

ASBESTOS

CONTENT

FLOORING

(SF) WALLS (SF) CEILINGS (SF)

THERMAL

SYSTEM

INSULATION

MISCELLANEOUS

MATERIAL

(SF/LF)

12" x 12" Floor Tile - White ND

Floor Tile Mastic ND 2' x 2' Ceiling Tiles ND

Gray Cove Base ND Cove Base Mastic ND

Sheetrock ND Joint Compound ND

2' x 4' Ceiling Tiles ND Blue Carpet Mastic ND 2' x 2' Ceiling Tiles ND

Gray Cove Base ND Cove Base Mastic ND

Sheetrock ND Joint Compound ND

2' x 4' Ceiling Tiles ND Light Gray 2" Ceramic Floor Tile ND

Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND

Ceramic Floor Tile Mastic ND 2' x 2' Ceiling Tiles ND

Sheetrock ND Joint Compound ND

4" Light Pink Ceramic Wall Tile ND Ceramic Wall Tile Grout ND Gray Ceramic Floor Tile ND

Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND

Ceramic Floor Tile Mastic ND Pink Ceramic Floor Tile ND

Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND

Ceramic Floor Tile Mastic ND 2' x 2' Ceiling Tiles ND

Sheetrock ND Joint Compound ND

2' x 4' Ceiling Tiles ND 4" Tan Wall Tile ND Wall Tile Grout ND

4" Gray Cove Base ND Cove Base Mastic ND

Medical Suite of Exam Rooms and Offices

Office 296

Women's Locker Room in Medical Suite

Men's Locker Room in Medical Suite

Building 1 Stratton National Guard Base

Schenectady, NY

ROOM NAME SUSPECT MATERIALS

ASBESTOS

CONTENT

FLOORING

(SF) WALLS (SF) CEILINGS (SF)

THERMAL

SYSTEM

INSULATION

MISCELLANEOUS

MATERIAL

(SF/LF)

Gray Ceramic Floor Tile ND

Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND

Ceramic Floor Tile Mastic ND Tan Mottled 12" x 12" Floor Tile ND

Floor Tile Mastic ND 2' x 2' Ceiling Tiles ND 2' x 4' Ceiling Tiles ND

Sheetrock ND Joint Compound ND

4" Gray Cove Base ND Cove Base Mastic ND

Gray Ceramic Floor Tile ND Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND

Ceramic Floor Tile Mastic ND 2' x 2' Ceiling Tiles ND

Sheetrock ND Joint Compound ND

12" x 12" Floor Tile - White ND Floor Tile Mastic ND

12" x 12" Floor Tile - White and Black ND Underlying Beige Floor Tile ND

Sheetrock ND Joint Compound ND

2' x 2' Ceiling Tiles ND 2' x 4' Ceiling Tiles ND 4" Gray Cove Base ND Cove Base Mastic ND

Blue Carpet Mastic ND 12" x 12" Floor Tile - White and Black ND

Underlying Red Floor Tile 1.9% Red Floor Tile Mastic 2.7%

Underlying Tan Floor Tile <1% Sheetrock ND

Joint Compound ND 2' x 2' Ceiling Tiles ND 2' x 4' Ceiling Tiles ND 4" Tan Cove Base ND Cove Base Mastic ND

4" Dark Gray Cove Base ND Cove Base Mastic ND

Biomed Office (338)

1st Sargeants Office (340)

Medical Administrative Offices 342, 343, 347, 349, 350, 351

Supply Room / Office (324)

Inaccessible

Kitchen

Public Health Officer (341)

Building 1 Stratton National Guard Base

Schenectady, NY

ROOM NAME SUSPECT MATERIALS

ASBESTOS

CONTENT

FLOORING

(SF) WALLS (SF) CEILINGS (SF)

THERMAL

SYSTEM

INSULATION

MISCELLANEOUS

MATERIAL

(SF/LF)

12" x 12" Floor Tile - White and Black ND

Underlying Red Floor Tile 1.9% Red Floor Tile Mastic 2.7%

Underlying Tan Floor Tile <1% Sheetrock ND

Joint Compound ND 2' x 2' Ceiling Tiles ND 2' x 4' Ceiling Tiles ND 4" Gray Cove Base ND Cove Base Mastic ND

Pink and Green Ceramic Floor Tile ND Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND

Ceramic Floor Tile Mastic ND 2' x 2' Ceiling Tiles ND 2' x 4' Ceiling Tiles ND

Sheetrock ND Joint Compound ND

Dark Gray Ceramic Floor Tile ND Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND

Ceramic Floor Tile Mastic ND 2' x 4' Ceiling Tiles ND

Sheetrock ND Joint Compound ND

4" Gray Ceramic Wall Tiles ND Ceramic Tile Grout ND Blue Carpet Mastic ND

Sheetrock ND Joint Compound ND

2' x 2' Ceiling Tiles ND 4" Dark Gray Cove Base ND

Cove Base Mastic ND Blue Carpet Mastic ND

Sheetrock ND Joint Compound ND

2' x 2' Ceiling Tiles ND 4" Dark Gray Cove Base ND

Cove Base Mastic ND Blue Carpet Mastic ND

Sheetrock ND Joint Compound ND

2' x 2' Ceiling Tiles ND 4" Tan Cove Base ND Cove Base Mastic ND

Command Chief Suite

Janitor's Closet (346)

First Floor Corridor

Men's Bathroom

Mission Support Offices

Commander's Office in Mission Support

Building 1 Stratton National Guard Base

Schenectady, NY

ROOM NAME SUSPECT MATERIALS

ASBESTOS

CONTENT

FLOORING

(SF) WALLS (SF) CEILINGS (SF)

THERMAL

SYSTEM

INSULATION

MISCELLANEOUS

MATERIAL

(SF/LF)

Blue Carpet Mastic ND

Sheetrock ND Joint Compound ND

2' x 2' Ceiling Tiles ND 4" Tan Cove Base ND Cove Base Mastic ND Blue Carpet Mastic ND

Sheetrock ND Joint Compound ND

2' x 2' Ceiling Tiles ND

Comm. Manager's Office

Blue Carpet Mastic ND Sheetrock ND

Joint Compound ND 2' x 2' Ceiling Tiles ND 4" Tan Cove Base ND Cove Base Mastic ND Blue Carpet Mastic ND

Sheetrock ND Joint Compound ND

2' x 2' Ceiling Tiles ND 4" Tan Cove Base ND Cove Base Mastic ND

Telecomm Room (283) Inaccessible ND Tan Mottled 12" x 12" Floor Tile ND

Floor Tile Mastic ND 2' x 2' Ceiling Tiles ND

Sheetrock ND Joint Compound ND

4" Tan Ceramic Wall Tile ND Ceramic Wall Tile Grout ND 4" Dark Gray Cove Base ND

Cove Base Mastic ND 12" x 12" Floor Tile - White with Black ND

Floor Tile Mastic ND 4" Light Blue Cove Base ND

Cove Base Mastic ND 2' x 2' Ceiling Tiles ND

Sheetrock ND Joint Compound ND

Logistics Suite

Human Resources Suite (257)

Wing Reception Office

Public Affairs

Wing Conference Room (269)

Janitor's Closet (284)

Inaccessible

Building 1 Stratton National Guard Base

Schenectady, NY

ROOM NAME SUSPECT MATERIALS

ASBESTOS

CONTENT

FLOORING

(SF) WALLS (SF) CEILINGS (SF)

THERMAL

SYSTEM

INSULATION

MISCELLANEOUS

MATERIAL

(SF/LF)

4" Light Blue Cove Base ND

Cove Base Mastic ND 2' x 2' Ceiling Tiles ND

Sheetrock ND Joint Compound ND

Purple Carpet Mastic ND SIPRNET ROOM Inaccessible ND

Brown Carpet Mastic ND 4" Brown Cove Base ND Cove Base Mastic ND 2' x 4' Ceiling Tiles ND

Sheetrock ND Joint Compound ND

Gray Ceramic Floor Tile ND Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND

Ceramic Floor Tile Mastic ND 2' x 4' Ceiling Tiles ND

Sheetrock ND Joint Compound ND

4" Brown Cove Base ND Cove Base Mastic ND

Gray Ceramic Floor Tile ND Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND

Ceramic Floor Tile Mastic ND 2' x 4' Ceiling Tiles ND

Sheetrock ND Joint Compound ND

4" Brown Cove Base ND Cove Base Mastic ND 4" Tan Cove Base ND Cove Base Mastic ND

Pink and Green Ceramic Floor Tile ND Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND

Ceramic Floor Tile Mastic ND 2' x 4' Ceiling Tiles ND

Sheetrock ND Joint Compound ND

Payroll Suite Storage (280)

Main Payroll Vestibule

Logistics Suite Offices

Payroll Suite

Payroll Suite Kitchen (282)

Building 1 Stratton National Guard Base

Schenectady, NY

ROOM NAME SUSPECT MATERIALS

ASBESTOS

CONTENT

FLOORING

(SF) WALLS (SF) CEILINGS (SF)

THERMAL

SYSTEM

INSULATION

MISCELLANEOUS

MATERIAL

(SF/LF)

Light Gray 2" Ceramic Floor Tile ND

Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND

Ceramic Floor Tile Mastic ND 2' x 2' Ceiling Tiles ND

Sheetrock ND Joint Compound ND

4" Light Pink Ceramic Wall Tile ND Ceramic Wall Tile Grout ND

Pink and Green Ceramic Floor Tile ND Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND

Ceramic Floor Tile Mastic ND Brown 9" x 9" Floor Tile 5% 500 9" x 9" Floor Tile Mastic ND

2' x 4' Ceiling Tiles ND 2' x 2' Ceiling Tiles ND

Sheetrock ND Joint Compound ND

4" Brown Cove Base ND Cove Base Mastic ND Tan Carpet Mastic ND

Tan Floor Tile Beneath Carpet ND 2' x 2' Ceiling Tiles ND

Sheetrock ND Joint Compound ND

Tan Floor Tile Beneath Carpet ND 2' x 2' Ceiling Tiles ND

Sheetrock ND Joint Compound ND

Blue Carpet Mastic ND 4" Brown Cove Base ND Cove Base Mastic ND

Tan Mottled 12" x 12" Floor Tile ND Floor Tile Mastic ND

Tan Floor Tile Beneath Mottled 12" x 12" Floor Tile ND

4" Tan Cove Base ND Cove Base Mastic ND

Sheetrock ND Joint Compound ND

2' x 2' Ceiling Tiles ND

Interior of the Building - Second Floor

Corridor 220

Wellness Center Reception

Wellness Center Offices

Legal Office Suite

Women's Restroom (272)

Building 1 Stratton National Guard Base

Schenectady, NY

ROOM NAME SUSPECT MATERIALS

ASBESTOS

CONTENT

FLOORING

(SF) WALLS (SF) CEILINGS (SF)

THERMAL

SYSTEM

INSULATION

MISCELLANEOUS

MATERIAL

(SF/LF)

Brown Carpet Mastic ND

Tan Floor Tile Beneath Carpet ND

4" Tan Cove Base ND Cove Base Mastic ND

Sheetrock ND Joint Compound ND

2' x 2' Ceiling Tiles ND Purple Carpet Mastic ND

Sheetrock ND Joint Compound ND

2' x 2' Ceiling Tiles ND SARC Office Inaccessible ND

4" Tan Cove Base ND Cove Base Mastic ND

Tan 12" x 12" Floor Tile with Brown ND Floor Tile Mastic ND

2' x 2' Ceiling Tiles ND Sheetrock ND

Joint Compound ND Gray Ceramic Floor Tile ND

Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND

Ceramic Floor Tile Mastic ND Sheetrock ND

Joint Compound ND 4" Blue Ceramic Wall Tile ND Ceramic Wall Tile Grout ND

2' x 2' Ceiling Tiles ND Blue Carpet Mastic ND Ceramic Floor Tile ND

Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND

Ceramic Floor Tile Mastic ND Sheetrock ND

Joint Compound ND 2' x 2' Ceiling Tiles ND

4" Brown Cove Base ND Cove Base Mastic ND 4" Tan Cove Base ND Cove Base Mastic ND

Men's Bathroom (239, 240)

Women's Bathroom (237, 238)

Legal Offices

Wing Safety Offices (229)

Equal Opportunity Offices

Building 1 Stratton National Guard Base

Schenectady, NY

ROOM NAME SUSPECT MATERIALS

ASBESTOS

CONTENT

FLOORING

(SF) WALLS (SF) CEILINGS (SF)

THERMAL

SYSTEM

INSULATION

MISCELLANEOUS

MATERIAL

(SF/LF)

Gray Ceramic Floor Tile ND

Ceramic Floor Tile Bedding Grout ND Ceramic Floor Tile Seam Grout ND

Ceramic Floor Tile Mastic ND Sheetrock ND

Joint Compound ND 2' x 2' Ceiling Tiles ND Gray Carpet Mastic ND

Brown 9" x 9" Floor Tile 5% 2,822 9" x 9" Floor Tile Mastic ND

Brown 9" x 9" Floor Tile 5% 215 9" x 9" Floor Tile Mastic ND

Wall Plaster ND Sheetrock ND

Joint Compound ND Blue Carpet Mastic ND

Sheetrock ND Joint Compound ND

2' x 2' Ceiling Tiles ND 4" Light Blue Cove Base ND

Cove Base Mastic ND Sheetrock ND

Joint Compound ND 2' x 2' Ceiling Tiles ND

4" Light Blue Cove Base ND Cove Base Mastic ND

12" x 12" Floor Tile - White with Black ND Floor Tile Mastic ND

4" Tan Cove Base ND Cove Base Mastic ND

4" Brown Cove Base ND Cove Base Mastic ND

Brown 9" x 9" Floor Tile 5% 227 9" x 9" Floor Tile Mastic ND

Sheetrock ND Joint Compound ND

2' x 2' Ceiling Tiles ND 2' x 4' Ceiling Tiles ND

Roof Access Stairwell

(228) No Suspect ACM observed ND

Recruiting Office Suite (215)

Stairwell (222)

Flight Personnel Office (207)

Flight Personnel Break Room (226)

Main Stairwell (227)

TABLE A-3

PAINT CHIP SAMPLE SUMMARY

Building 1 Stratton National Guard Base

Schenectady, NY

Sample No. Paint Chip Description Sample Location % Lead (By Weight)

LBP-01 White Ceiling Paint <0.01% LBP-02 White Wall Paint <0.01% LBP-03 Blue Wall Paint Second Floor Flight Personnel Office <0.01%

0.5% = Lead-Based Paint (EPA and HUD)

First Floor Corridor

CHA Consulting, Inc. LBP Survey

APPENDIX B

Historical Asbestos Information

APPENDIX C

Current Bulk Asbestos Sample Analysis

EMSL Analytical, Inc.

307 West 38th Street, New York, NY 10018 Phone/Fax: (212) 290-0051 / (212) 290-0058 http://www.emsl.com manhattanlab@emsl.com

031208775 CustomerID: CLOU50 CustomerPO:

ProjectID:

EMSL Order:

Attn: Jim Morey

CHA

3 Winners Circle Albany, NY 12205 Received: 03/23/2012 9:31 AM

STRATTON NGB

Fax: (518) 453-4773 Phone: (518) 453-8702 Project:

3/27/2012Analysis Date:

Collected: 3/20/2012

Analyzed Date Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor

Non Asbestos

Test Report:Asbestos Analysis of Bulk Material

01A 031208775-0001

2'X4' CEILING TILE

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Gray

Gray

Glass14.5%

01B 031208775-0002

2'X4' CEILING TILE

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Gray

Gray

Glass16.2%

02A 031208775-0003

2'X2' CEILING TILE

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Gray

Gray

Glass1.9%

02B 031208775-0004

2'X2' CEILING TILE

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Gray

Gray

Glass13.5%

03A 031208775-0005

2'X2' CEILING TILE BOX PATTERN

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Gray

Gray

Glass11.7%

03B 031208775-0006

2'X2' CEILING TILE BOX PATTERN

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Gray

Gray

Glass9.1%

04A 031208775-0007

4" BLACK COVE BASE MASTIC

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Yellow

Yellow

Page 1Test Report NY198w/A-7.21.0 Printed: 3/30/2012 8:44:21 AM

Initial Report From 03/30/2012 08:44:21 http://www.emsl.com mailto:manhattanlab@emsl.com

Phone/Fax: (212) 290-0051 / (212) 290-0058 http://www.emsl.com manhattanlab@emsl.com

031208775 CustomerID: CLOU50 CustomerPO:

ProjectID:

EMSL Order:

Attn: Jim Morey

CHA

3 Winners Circle Albany, NY 12205 Received: 03/23/2012 9:31 AM

STRATTON NGB

Fax: (518) 453-4773 Phone: (518) 453-8702 Project:

3/27/2012Analysis Date:

Collected: 3/20/2012

Analyzed Date Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor

Non Asbestos

Test Report:Asbestos Analysis of Bulk Material

04B 031208775-0008

4" BLACK COVE BASE MASTIC

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Yellow

Yellow

05A 031208775-0009

4" BLACK COVE BASE

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

05B 031208775-0010

4" BLACK COVE BASE

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Black

Black

06A 031208775-0011

4" DARK TAN COVE BASE MASTIC

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Yellow

Yellow

06B 031208775-0012

4" DARK TAN COVE BASE MASTIC

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Yellow

Yellow

07A 031208775-0013

4" DARK TAN COVE BASE

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Brown

Brown

07B 031208775-0014

4" DARK TAN COVE BASE

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Brown

Brown

Page 2Test Report NY198w/A-7.21.0 Printed: 3/30/2012 8:44:21 AM

Initial Report From 03/30/2012 08:44:21

Phone/Fax: (212) 290-0051 / (212) 290-0058 http://www.emsl.com manhattanlab@emsl.com

031208775 CustomerID: CLOU50 CustomerPO:

ProjectID:

EMSL Order:

Attn: Jim Morey

CHA

3 Winners Circle Albany, NY 12205 Received: 03/23/2012 9:31 AM

STRATTON NGB

Fax: (518) 453-4773 Phone: (518) 453-8702 Project:

3/27/2012Analysis Date:

Collected: 3/20/2012

Analyzed Date Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor

Non Asbestos

Test Report:Asbestos Analysis of Bulk Material

08A 031208775-0015

4" LIGHT BLUE COVE BASE MASTIC

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Yellow

Yellow

08B 031208775-0016

4" LIGHT BLUE COVE BASE MASTIC

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Yellow

Yellow

09A 031208775-0017

4" LIGHT BLUE COVE BASE

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Blue

Blue

09B 031208775-0018

4" LIGHT BLUE COVE BASE

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Blue

Blue

10A 031208775-0019

4" BROWN COVE BASE MASTIC

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Yellow

Yellow

10B 031208775-0020

4" BROWN COVE BASE MASTIC

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Yellow

Yellow

11A 031208775-0021

4" BROWN COVE BASE

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Brown

Brown

Page 3Test Report NY198w/A-7.21.0 Printed: 3/30/2012 8:44:21 AM

Initial Report From 03/30/2012 08:44:21

Phone/Fax: (212) 290-0051 / (212) 290-0058 http://www.emsl.com manhattanlab@emsl.com

031208775 CustomerID: CLOU50 CustomerPO:

ProjectID:

EMSL Order:

Attn: Jim Morey

CHA

3 Winners Circle Albany, NY 12205 Received: 03/23/2012 9:31 AM

STRATTON NGB

Fax: (518) 453-4773 Phone: (518) 453-8702 Project:

3/27/2012Analysis Date:

Collected: 3/20/2012

Analyzed Date Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor

Non Asbestos

Test Report:Asbestos Analysis of Bulk Material

11B 031208775-0022

4" BROWN COVE BASE

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Brown

Brown

12A 031208775-0023

4" GRAY COVE BASE MASTIC

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Yellow

Yellow

12A 031208775-0024

4" GRAY COVE BASE MASTIC

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Yellow

Yellow

13A 031208775-0025

4" GRAY COVE BASE

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Gray

Gray

13B 031208775-0026

4" GRAY COVE BASE

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Gray

Gray

14A 031208775-0027

4" TAN COVE BASE MASTIC

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Yellow

Yellow

14B 031208775-0028

4" TAN COVE BASE MASTIC

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Yellow

Yellow

Page 4Test Report NY198w/A-7.21.0 Printed: 3/30/2012 8:44:21 AM

Initial Report From 03/30/2012 08:44:21

Phone/Fax: (212) 290-0051 / (212) 290-0058 http://www.emsl.com manhattanlab@emsl.com

031208775 CustomerID: CLOU50 CustomerPO:

ProjectID:

EMSL Order:

Attn: Jim Morey

CHA

3 Winners Circle Albany, NY 12205 Received: 03/23/2012 9:31 AM

STRATTON NGB

Fax: (518) 453-4773 Phone: (518) 453-8702 Project:

3/27/2012Analysis Date:

Collected: 3/20/2012

Analyzed Date Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor

Non Asbestos

Test Report:Asbestos Analysis of Bulk Material

15A 031208775-0029

4" TAN COVE BASE

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Tan

Tan

15B 031208775-0030

4" TAN COVE BASE

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Tan

Tan

16A 031208775-0031

4" LIGHT GRAY COVE BASE MASTIC

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Yellow

Yellow

16B 031208775-0032

4" LIGHT GRAY COVE BASE MASTIC

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Yellow

Yellow

17A 031208775-0033

4" LIGHT GRAY COVE BASE

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Gray

Gray

17B 031208775-0034

4" LIGHT GRAY COVE BASE

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Gray

Gray

18A 031208775-0035

BLUE CARPET MASTIC

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Yellow

Yellow

Page 5Test Report NY198w/A-7.21.0 Printed: 3/30/2012 8:44:21 AM

Initial Report From 03/30/2012 08:44:21

Phone/Fax: (212) 290-0051 / (212) 290-0058 http://www.emsl.com manhattanlab@emsl.com

031208775 CustomerID: CLOU50 CustomerPO:

ProjectID:

EMSL Order:

Attn: Jim Morey

CHA

3 Winners Circle Albany, NY 12205 Received: 03/23/2012 9:31 AM

STRATTON NGB

Fax: (518) 453-4773 Phone: (518) 453-8702 Project:

3/27/2012Analysis Date:

Collected: 3/20/2012

Analyzed Date Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor

Non Asbestos

Test Report:Asbestos Analysis of Bulk Material

18B 031208775-0036

BLUE CARPET MASTIC

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Yellow

Yellow

19A 031208775-0037

PURPLE CARPET MASTIC

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Yellow

Yellow

19B 031208775-0038

PURPLE CARPET MASTIC

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Yellow

Yellow

20A 031208775-0039

TAN CARPET MASTIC

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Yellow

Yellow

20B 031208775-0040

TAN CARPET MASTIC

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Yellow

Yellow

21A 031208775-0041

BROWN CARPET MASTIC/LEVELING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Yellow

Yellow Fibrous (other)<1%

21B 031208775-0042

BROWN CARPET MASTIC/LEVELING

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

Yellow

Yellow

Page 6Test Report NY198w/A-7.21.0 Printed: 3/30/2012 8:44:21 AM

Initial Report From 03/30/2012 08:44:21

Phone/Fax: (212) 290-0051 / (212) 290-0058 http://www.emsl.com manhattanlab@emsl.com

031208775 CustomerID: CLOU50 CustomerPO:

ProjectID:

EMSL Order:

Attn: Jim Morey

CHA

3 Winners Circle Albany, NY 12205 Received: 03/23/2012 9:31 AM

STRATTON NGB

Fax: (518) 453-4773 Phone: (518) 453-8702 Project:

3/27/2012Analysis Date:

Collected: 3/20/2012

Analyzed Date Sample Description Asbestos Fibrous Non-FibrousTest CommentsColor

Non Asbestos

Test Report:Asbestos Analysis of Bulk Material

22A 031208775-0043

12"X12" FLOOR TILE (WHITE W./ BLACK)

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

White

White

22B 031208775-0044

12"X12" FLOOR TILE (WHITE W./ BLACK)

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconclusive: None Detected

None Detected

White

White

23A 031208775-0045

MASTIC TO 12"X12" FLOOR TILE

PLM NYS 198.1 Friable

PLM NYS 198.6 NOB

TEM NYS 198.4 NOB

3/25/2012

3/27/2012

Not Analyzed

N/A

N/A

Inconcl…

This is the start of the file's text. The full file is on GovTribe.