STRATTON
AIR
NATIONAL
GUARD
BASE
Building 27 Renovations
STRATTON AIR NATIONAL GUARD BASE
26-Jan-12
BASE BID
Sequence # Item Unit Qty Cost/Unit Total Cost Division 1 - General Requirements 01043 Job Site Superintendent Monthly 01200 Project Meetings
LS
01300 Submittals
LS
01340 Shop Drawings
LS
01700 Contract Closeout
LS
01710 Final Cleaning & Dumpsters
LS
01740 Bonds & Insurances
LS
Division 2 - Site Construction Excavation for Generator Pad
LS
Division 3 - Concrete Generator Pad
YD
Division 4 - Masonry Comprehensive Unit Masonry Cavity Wall w/ 2" Rigid Insulation & 4" Split Face Veneer
LS
Masonry Opening between Orderly & Copy Rm
LS
Division 5 - Steel 05500 RTU Support Framing
LS
Division 6 - Wood & Plastics 06402 Solid Surface Countertop at Customer Service includes Support Framing
EA
06402 Plastic Laminate Countertop at Mail Room includes Support Framing
EA
06402 Conference Room Cabinets
EA
06402 Cherry Veneer Paneling
SF
Division 7 - Thermal & Moisture Protection N/A Division 8 - Doors & Windows 08110 Steel Door Frames
EA
08110 Steel Borrowed Light Frames (Interior Windows)
SF
08141 Solid Core Wood Door & Hardware
EA
08311 Access Doors & Frames
EA
08331 Remove & Install Overhead Coiling Door
EA
08505 Removal of Existing Window in the Switch Room
EA
08580 Sliding Service Window
EA
08800 Glazing
SF
Division 9 - Finishes 09290 Selective Demolition - Gypsum Board Partitions
SF
09291 Gypsum Board Partitions
SF
09301 Quarry Tile Flooring
SF
09510 Selective Demolition - Ceilings
SF
09511 Acoustical Panel Ceiling
SF
09651 Vinyl Composition Tile
SF
09653 Conductive Vinyl Flooring
SF
09680 Selective Demolition -Sheet Carpet
SY
09681 32 oz. Sheet Carpet
SY
09912 Painting
SF
13175
8/2/2011
STRATTON AIR NATIONAL GUARD BASE
Building 27 Renovations
STRATTON AIR NATIONAL GUARD BASE
26-Jan-12
BASE BID
| Sequence # |
| Item |
| Unit |
| Qty |
| Cost/Unit |
| Total Cost |
Division 10 - Specialties
| 10270 |
| Access Flooring |
| SF |
| 240 |
10550 Install Owner Provided Horizontal Mail Boxes EA 3 $
Division 11 - Equipment
| 11132 |
| Project Screen |
| EA |
| 1 |
Division 12 - Furnishings
N/A
Division 13 - Special Construction
N/A
Division 14 - Conveying Systems
N/A
Division 15 - Mechanical, Plumbing & Fire Protection
| 15010 |
| Fire Protection Demolition |
| SF |
| 500 |
| 15010 |
| Remove Air Handlers |
| EA |
| 3 |
| 15010 |
| Remove Controls System |
| LS |
| 1 |
| 15010 |
| Remove Hydronic Piping |
| FT |
| 260 |
| 15010 |
| Remove Ductwork |
| Pounds |
| 800 |
| 15010 |
| Remove VAV Boxes |
| EA |
| 10 |
| 15010 |
| Remove Difusers/Grilles |
| EA |
| 60 |
| 15010 |
| Remove Duct Coils |
| EA |
| 3 |
| 15010 |
| Remove Finned Tube |
| EA |
| 2 |
| 15010 |
| Crane for a Day |
| Day |
| 2 |
| 15010 |
| Miscellaneous Removals |
| LS |
| 1 |
| 15050 |
| Storm Drain Relocation |
| LS |
| 1 |
| 15050 |
| Roof Top Unit Modifications |
| LS |
| 1 |
| 15050 |
| Comissioning |
| LS |
| 1 |
| 15250 |
| Hot Water Piping Insulation |
| FT |
| 480 |
| 15250 |
| Duct Insulation |
| SF |
| 2200 |
| 15366 |
| Clean agent system |
| EA |
| 3 |
| 15510 |
| 3/4" Hot Water Piping |
| FT |
| 400 |
| 15510 |
| 1-1/2" Hot Water Piping |
| FT |
| 80 |
| 15530 |
| Refrigerant Piping |
| LS |
| 1 |
| 15738 |
| Ductless Split System (2 Ton) |
| EA |
| 2 |
| 15738 |
| Ductless Split System (3 Ton) |
| EA |
| 2 |
| 15782 |
| Rooftop Unit (10 Ton) |
| EA |
| 2 |
| 15855 |
| Diffusers/Grilles |
| EA |
| 60 |
| 15891 |
| Galvanized Steel Ductwork |
| Pounds |
| 3200 |
| 15891 |
| Duct Cleaning |
| LS |
| 1 |
| 15891 |
| Duct Liner |
| SF |
| 600 |
| 15933 |
| VAV Box |
| EA |
| 15 |
| 15975 |
| Controls |
| LS |
| 1 |
| 15990 |
| Balancing |
| LS |
| 1 |
Division 16 - Electrical Systems
Removal
| 16060 |
| 2 x 4 Recessed Lights |
| EA |
| 57 |
| 16060 |
| 1 x 4 Recessed Lights w/lamps |
| EA |
| 8 |
| 16060 |
| Downlight Fixture |
| EA |
| 24 |
| 16060 |
| Switches |
| EA |
| 24 |
| 16060 |
| Homeruns |
| EA |
| 20 |
| 16060 |
| Receptacles |
| EA |
| 51 |
| 16060 |
| Emergency Battery Packs |
| EA |
| 3 |
8/2/2011
STRATTON AIR NATIONAL GUARD BASE
Building 27 Renovations
STRATTON AIR NATIONAL GUARD BASE
26-Jan-12
BASE BID
| Sequence # |
| Item |
| Unit |
| Qty |
| Cost/Unit |
| Total Cost |
| 16060 |
| Data Outlets |
| EA |
| 26 |
| 16060 |
| Telephone Outlets |
| EA |
| 1 |
| 16060 |
| Speakers |
| EA |
| 18 |
| 16060 |
| Heat Detectors |
| EA |
| 15 |
| 16060 |
| Exit Signs |
| EA |
| 7 |
| 16060 |
| TV Connection |
| EA |
| 2 |
| 16060 |
| Smoke Detectors |
| EA |
| 4 |
| 16060 |
| TV Coax |
| CLF |
| 1 |
| 16060 |
| Fire Alarm Horn and Strobe |
| EA |
| 1 |
| 16060 |
| Junction Boxes |
| EA |
| 10 |
| 16130 |
| Disconnects |
| EA |
| 1 |
| 16915 |
| Motion Sensors |
| EA |
| 3 |
| 16915 |
| Occupancy Senors |
| EA |
| 20 |
New
| 16120 |
| Power Wiring |
| CLF |
| 20 |
| 16140 |
| Receptacles - IG |
| EA |
| 41 |
| 16140 |
| Receptacles - Duplex |
| EA |
| 29 |
| 16140 |
| Receptacles - Covers |
| EA |
| 70 |
| 16510 |
| Downlight Fixture |
| EA |
| 23 |
| 16510 |
| 2 x 4 Recessed Lights w/lamps |
| EA |
| 73 |
| 16510 |
| Exit Sign - Single Face |
| EA |
| 8 |
| 16510 |
| Exit Sign - Double Face |
| EA |
| 2 |
| 16510 |
| Emergency Battery Packs |
| EA |
| 10 |
| 16720 |
| Duct Detectors |
| EA |
| 3 |
| 16720 |
| Smoke Detectors(UNDER FLOOR) |
| EA |
| 2 |
| 16720 |
| Smoke/Heat Combo detector |
| EA |
| 7 |
| 16720 |
| Smoke Detectors |
| EA |
| 4 |
| 16720 |
| Heat Detector |
| EA |
| 10 |
| 16720 |
| Fire Alarm Strobe |
| EA |
| 5 |
| 16720 |
| Fire Alarm Strobe and Horn |
| EA |
| 2 |
| 16720 |
| Pull Station |
| EA |
| 1 |
| 16740 |
| Data/Tele Outlets |
| EA |
| 54 |
| 16740 |
| Data/Tele Outlets Covers |
| EA |
| 54 |
| 16740 |
| Data wiring - Cat5 |
| CLF |
| 25 |
| 16740 |
| Telephone Wiring |
| CLF |
| 1 |
| 16770 |
| Speakers |
| EA |
| 15 |
| 16770 |
| Speaker Wire |
| LF |
| 700 |
| 16120 |
| TV Coax |
| CLF |
| 2 |
| 16140 |
| TV Connection |
| EA |
| 2 |
| 16140 |
| Dimmer Switch |
| EA |
| 2 |
| 16140 |
| Dimmer Switch Cover |
| EA |
| 2 |
| 16140 |
| Light Switch |
| EA |
| 40 |
| 16140 |
| Light Switch Cover |
| EA |
| 36 |
| 16470 |
| 20A/1P breakers |
| EA |
| 25 |
| 16470 |
| 40A/2P breakers |
| EA |
| 1 |
| 16470 |
| 60A/3P breakers |
| EA |
| 2 |
| 16470 |
| 15A/2P breakers |
| EA |
| 3 |
| 16470 |
| 25A/2P breakers |
| EA |
| 2 |
| 16470 |
| 200A/3P Circuit breaker |
| EA |
| 2 |
| 16470 |
| 30A/3P Circuit breaker |
| EA |
| 1 |
| 16470 |
| Panelboard 120/208V w/42 ckts |
| EA |
| 2 |
8/2/2011
STRATTON AIR NATIONAL GUARD BASE
Building 27 Renovations
STRATTON AIR NATIONAL GUARD BASE
26-Jan-12
BASE BID
| Sequence # |
| Item |
| Unit |
| Qty |
| Cost/Unit |
| Total Cost |
| 16915 |
| Occupancy Sensor |
| EA |
| 20 |
| 16915 |
| motion sensors |
| EA |
| 4 |
| 16120 |
| Lighting Wire |
| LF |
| 3100 |
| 16120 |
| Fire Alarm Wiring |
| LF |
| 500 |
| 16120 |
| Conduit supports |
| EA |
| 100 |
| 16130 |
| Wall Mounted Junction Box |
| EA |
| 8 |
| 16130 |
| Motor Starter Switch |
| EA |
| 15 |
| 16130 |
| Disconnects |
| EA |
| 6 |
| 16131 |
| Cable tray |
| LF |
| 50 |
| Enviroalert Panel and accessories |
| EA |
| 1 |
| 16120 |
| Wire w/ground |
| LF |
| 12400 |
Re-Installations
| Lights |
| EA |
| 22 |
| Speakers |
| EA |
| 4 |
| Camera |
| EA |
| 1 |
| Keypad |
| EA |
| 3 |
| Twist lock receptacles |
| EA |
| 3 |
| Relocated Security Equipment by Advantor Tech |
| EA |
| 3 |
Total: