TECHNICAL SUMMARY OF CHANGES MOTSU Annual Roofs.pdf
PDF 287 KB Posted
- Attached to
- MOTSU-22018 Annual Roof Repairs Federal contract opportunity
- Solicitation number
- W912PM22B0010
About this file
This solicitation is for roof replacement services at the Military Ocean Terminal Sunny Point in Southport, North Carolina. The U.S. Army Corps of Engineers, Wilmington District is seeking a firm-fixed price contract to replace the roofs of Building 26 and Building 32. For Building 26, the base bid involves demolishing the existing single-ply roof membrane and insulation down to the metal deck and replacing it with a new 2-ply modified bitumen roof system and insulation. The work area is approximately 10,400 square feet. For Building 32, this is listed as Optional Bid Item 1 and involves replacing its roof over an area of 3,100 square feet. Both projects include reflashing penetrations and parapets and replacing prefinished metal parapet caps. The North American Industry Classification System code is 238160 for Roofing Contractors and the size standard is $16.5 million. The magnitude of construction is between $1-5 million. This solicitation is set aside for Service-Disabled Veteran-Owned Small Businesses and offers are due by the date specified on SAM.gov where the full solicitation is posted.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Bid Opening Sign-In Sheet.pdf | ||
| B1 Abstract W912PM22B0010_Electronic_SIGNED.pdf | ||
| W912PM22B00100003.pdf | ||
| LP System Site Visit Pictures.pdf | ||
| LP System Site Visit Roster.pdf | ||
| W912PM22B00100003 (conformed).pdf | ||
| NCIC_CONSENT_FORM.pdf | ||
| Bldg32AsBuilts.pdf | ||
| W912PM22B00100002 (conformed).pdf | ||
| W912PM22B00100002.pdf | ||
| Bldg26AsBuilts.pdf | ||
| REV D_Amend 01_A-102_Bldg 26 - Arch Roof Plan-RTA.pdf | ||
| REV D_Amend 01_A-101_Bldg 32 - Arch Roof Plan-RTA-2.pdf | ||
| Roof1-converted-compressed.pdf | ||
| W912PM22B00100001 (conformed).pdf | ||
| W912PM22B00100001.pdf | ||
| 07 52 00 - AMDT0001.pdf | ||
| SiteVisitSignIn.pdf | ||
| NCIC CONSENT FORM.pdf | ||
| RTA-SPECS-MOTSU-22018-Roof Repairs.pdf | ||
| 2022_04.26_RTA_MOTSU 22018 - ANNUAL ROOF REPAIRS MILITARY OCEAN TERMINAL.pdf | ||
| W912PM22B0010.pdf |
Show all 22
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MOTSU 22018 Annual Roof Repairs
Amendment 01 May 19, 2022
TECHNICAL SUMMARY OF CHANGES
1) Lightning Protection Scope of Work was added to Sheets A-101 and A-102.
2) Specification Section 07 52 00, Item 2.13 was revised to require minimum R-38 roof insulation, which is the MOTSU Energy Standard, from the original R-25.
3) Inset for mechanical equipment on Bldg 32 was shown on Sheet A-101 as being Optional Bid
Item 2.
4) Sections that are to receive Hot Process or Cold Process roof installation method was shown on
Sheet A-101.