Bldg26AsBuilts.pdf
PDF 41 MB Posted
- Attached to
- MOTSU-22018 Annual Roof Repairs Federal contract opportunity
- Solicitation number
- W912PM22B0010
About this file
This document provides details for a federal contract solicitation issued by the U.S. Army Corps of Engineers Engineering District Wilmington. The solicitation seeks to award a firm-fixed price contract for annual roof repairs at the Military Ocean Terminal Sunny Point in Southport, North Carolina. Specifically, the selected contractor will replace the roofs of Building 26 and optionally Building 32 with a new two-ply modified bitumen roof system including demolition of existing roofs, new insulation, and repairs to penetrations and parapets. The base bid area for Building 26 is approximately 10,400 square feet and the optional bid item area for Building 32 is 3,100 square feet. The North American Industry Classification System code is 238160 for roofing contractors and the estimated magnitude of construction is between $1,000,000 to $5,000,000. This is a set-aside for Service-Disabled Veteran-Owned Small Businesses. The point of contact for any questions is the listed contracting specialist and officer.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Bid Opening Sign-In Sheet.pdf | ||
| B1 Abstract W912PM22B0010_Electronic_SIGNED.pdf | ||
| LP System Site Visit Pictures.pdf | ||
| W912PM22B00100003 (conformed).pdf | ||
| LP System Site Visit Roster.pdf | ||
| W912PM22B00100003.pdf | ||
| NCIC_CONSENT_FORM.pdf | ||
| Bldg32AsBuilts.pdf | ||
| W912PM22B00100002 (conformed).pdf | ||
| W912PM22B00100002.pdf | ||
| 07 52 00 - AMDT0001.pdf | ||
| TECHNICAL SUMMARY OF CHANGES MOTSU Annual Roofs.pdf | ||
| SiteVisitSignIn.pdf | ||
| REV D_Amend 01_A-102_Bldg 26 - Arch Roof Plan-RTA.pdf | ||
| REV D_Amend 01_A-101_Bldg 32 - Arch Roof Plan-RTA-2.pdf | ||
| Roof1-converted-compressed.pdf | ||
| W912PM22B00100001 (conformed).pdf | ||
| W912PM22B00100001.pdf | ||
| RTA-SPECS-MOTSU-22018-Roof Repairs.pdf | ||
| W912PM22B0010.pdf | ||
| 2022_04.26_RTA_MOTSU 22018 - ANNUAL ROOF REPAIRS MILITARY OCEAN TERMINAL.pdf | ||
| NCIC CONSENT FORM.pdf |
Show all 22
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INSULATION (LOOSE OR BATT)
BRICK
WOOD (BLOCKING)
WOOD (FINISH)
INSULATION (RIGID)
MORTAR - CEMENT - PLASTER - STUCCO
METAL (ELEVATION)
STEEL (CROSS-SECTION)
CONCRETE
EARTH (COMPACTED FILL)
GRAVEL
EARTH (ORIGINAL GRADE)
S T A N D A R D A B B R E V I A T I O N S
M A T E R I A L L E G E N D
DRAWING TITLE
CONCRETE MASONRY UNITS (SMALL SCALE)
CONCRETE MASONRY UNITS (LARGE SCALE)
CONCRETE MASONRY UNITS OR HOLLOW TILE
CENTER TO CENTER
CERAMIC TILE BASE
CONSTRUCTION JOINT
CONCRETE MASONRY UNIT
CONSTRUCTION
EMPTY CONDUIT
CONT.
BALANCEBAL.
CONTINUOUS
BRITISH THERMO UNIT/HOUR
CEILING DIFFUSER
CUBIC FEET/MINUTE
CIRCULATINGCIRC.
CK'D.
C.J.
CHECKERED
CONTROL JOINT
BLDG.
C.F.M.
B.T.U.H.
C.D.
CEM.
CER.
CAP.
CAB.
BM.
BOT.
BRG.
BLK.
BRD.
CEMENT
CAPACITY
CABINET
CERAMIC
BLANK
BEARING
BOTTOM
BEAM
BUILDING
BOARD
EACHEA.
E.F.
E.C.
EXHAUST FAN
C.T.B.
C. TO C.
DET.
DIM.
DWG.(S)
DISC.
DIFF.
DR.
D.S.
DN.
D.J.
DIA.
C.T.
DIMENSION
DRAIN
DOWN
DRAWING(S)
DOWNSPOUT
DUMMY JOINT
DISCONNECT
DETAIL
CERAMIC TILE
DIFFUSER
DIAMETER
AIR HANDLING UNIT
ACCESS OPENING
AIR CONDITIONED
ACOUSTIC CEILING TILE
ARCHITECTURAL
APPROXIMATELY
A.H.U.
ALUM.
AMP, A.
ARCH.
A.C.T.
APPROX.
A.T.
A.O.
A.C.
A.D.
ALT.
ALUMINUM
AMPERES
ASPHALT TILE
ALTERNATE
AREA DRAIN
CL.
CKT.
C.M.U.
CEIL.
COL.
CONN.
CONST. JT.
CONST.
COND.
CONC.
CL.
COLUMN
CONNECTION
CONDENSATE
CONCRETE
CIRCUIT
CLOSET
CEILING
CENTERLINE
OPEN SIGHT DRAIN
OPPOSITE
PERIMETER
PARTITION
POUNDS/SQUARE INCH
QUARTER
PAINTED
POUNDS/SQUARE FOOT
PRESSURE
PLYWOOD
PLUMBING
PLASTIC LAMINATE
REQUIRED
RECIRCULATING
REINFORCING
REGISTER
RECEPTACLE
RECEIVED
RETURN AIR
HOLLOW METAL
HOLLOW CORE
GYPSUM WALL BOARD
HORSE POWER
INSIDE DIAMETER
HEATING AND VENTILATING
JUNCTION BOX
INSULATION
KILOVOLT AMPERE
INCANDESCENT
H&V
F.D. FLOOR DRAIN
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
GALLONS/HOUR
GOVERNMENT
GALLONS/MINUTE
GOV'T FURNISHED EQUIPMENT
FIELD VERIFY
G.P.H.
GR.
G.P.M.
GRILLE
FIN.
FT.
FTG.
FL.
F.E.C.
F.E.
GAL.
GA.
GL.
G.F.E.
GALV.
GND.
GOV'T.
F.V.
GALVANIZED
GROUND
GLASS
GALLON
GAGE
FLOOR
FINISH
FOOT, FEET
FOOTING
KILOWATTKW.
LB. POUND
HYD.
IN.
I.D.
HW.
INT.
INSUL.
JCT.
J.B.
JT.
KVA.
INCAND.
JUNCTION
JOINT
INTERIOR
INCHES
HYDRANT
HARDWARE
ELECTRIC WATER COOLER
EXPANSION JOINT
FLEXIBLE CONNECTION
EL.
EQ.
EXH.
EXP. JT.
ELEC.
E.W.C.
EQUIP.
EXT.
F.C.
F.A.
EXIST.
EXHAUST
FIRE ALARM
EXISTING
EXTERIOR
ELECTRIC
EQUIPMENT
ELEVATION
EQUAL
GWB.
H.
GYP.
H.M.
H.C.
H.B.
HT.
HR.
H.P
HTR.
HTG.
HOSE BIBB
HOUR
HEATER
HEATING
HEIGHT
GYPSUM
HIGH
PSF.
MISCELLANEOUSMISC.
MOUNTING
MASONRY OPENING
MECHANICAL VENTILATION
METAL THRESHOLD
ON CENTER
OVERHEAD
OUTSIDE DIAMETER
OUTDOOR AIR
NOT IN CONTRACT
NOT APPLICABLE
OH.
OPNG. OPENING
N.A.
O.A.
O.D.
O.C.
OFF.
N.I.C.
NO.
OFFICE
NUMBER
MTG.
MTL.
M.V.
MTD.
M.O.
M.T.
METAL
MOUNTED
REINF.
REQ.
R. RISER
REC'D.
RECIRC.
RECP.
REG.
RAD.
R.A.
RD. ROUND
RADIUS
PTD.
QTR.
PSI.
PT. POINT
LIGHTING PANEL
MAINTENANCE
MAIN DISTRIBUTION PANEL
MATT GLAZE TILE
MECHANICAL
MOTORM.
M.D.P.
M.G.T.
MECH.
MIN.
MAINT.
MAX.
MINIMUM
MAXIMUM
LG.
LTG.
L.P.
LONG
LIGHTING
PART.
PLAS.LAM.
PLBG.
PLYWD.
PRESS.
PNL.
PER.
PL.
PANEL
PLATE
OPP.
O.S.D.
P. PAPER
TEMPERATURE
VOLT
THICKNESS
THRESHOLD
TYPICAL
TOILET
VERTICAL
VENTILATION
WATT
WATER GAGE
WIDE FLANGE
WOOD
WATER
VINYL COMPOSITION TILE
WEATHERPROOF
WINDOW DIMENSION
WELDED WIRE FABRIC
VENT THRU ROOF
WAINSCOATING
W.
SPECIFICATIONSSPEC.
STORAGE
SWITCH
STRUCTURAL
SUSPENDED
SQUARE FEET
TOILET
TELEPHONE
T.
TEL.
STRUCT.
SW.
SUSP.
STO.
STL.
SQ.FT.
STEEL
WTR.
W.W.F.
W.D.
W.F.
W.G.
WP.
WD.
WC.
W/ WITH
RETURN
SUPPLY
SUPPLY AIR
RETURN GRILLE
REVOLUTION/MINUTE
SERVICE
SECTION
SHEET
SLIP JOINT
SCHEDULE
SECT.
S.J.
SHT.
SERV.
S.
S.A.
SCH.
RET.
R.P.M.
RM.
R.G.
ROOM
TYP.
VENT.
VERT.
V.T.R.
V.
V.C.T.
TEMP.
THK.
TOIL.
THD.
SHEET No.
I N D E X O F D R A W I N G S
DRAWING TITLESHEET No.DOC No. DOC No.
INDEX OF DRAWINGS, SYMBOLS AND ABBREVIATIONS
DRAWING No. DRAWING No.
ELECTRICAL SYMBOL SCHEDULE
ELECTRICAL DETAILS
ELECTRICAL DETAILS
ELECTRICAL DETAILS
ELECTRICAL DETAILS
ELECTRICAL DEMOLITION PLANS
LIGHTING AND FIRE ALARM PLANS
POWER RISER AND PANEL SCHEDULES
POWER AND SIGNAL PLANS
US Army Corps of Engineers
Savannah District
CS
CA
D1
D2
A1
A2
A3
A4
A5
CODE ANALYSIS AND FINISH SCHEDULE
DEMOLITION EXTERIOR ELEVATIONS
REFLECTED CEILING PLAN AND CEILING DETAILS
ROOF PLAN AND ROOF DETAILS
A0 5
S1
S2
BUILDING PLANS AND DETAILS
GENERAL NOTES AND DETAILS
E1
E2
E3
E4
E5
E6
E7
E8
E9
CS
S Y
M B
O L
S
A B
B R
E V
IA
T
IO
N S
IN
D
E X
O F
D R
A W
IN
G S
M0.1
M0.2
MECHANICAL LEGENDS AND ABBREVIATIONS
FIRE PROTECTION DETAILS
M0.3 MECHANICAL SEISMIC DETAILS
M1 HVAC DEMOLITION PLAN
M2 PLUMBING PLANS, DETAILS AND SCHEDULES
M3 HVAC PLAN
M4
M5
HVAC SCHEDULES
HVAC DETAILS
FP1 FIRE PROTECTION PLAN
DEMOLITION FLOOR PLAN AND DEMOLITION ROOF PLAN
FLOOR PLAN AND TOILET ELEVATIONS
DOOR AND WINDOW TYPES AND DETAILS
EXTERIOR ELEVATIONS AND WALL SECTIONS
WALL TYPES, SIGNAGE, AND FEC DETAILS
M6 MECHANICAL SECTIONS
12345
D
C
B
A
5 4 3 2
A
B
C
D
$$DGNSPEC$$
$$SYSTIME$$
$$USERNAME$$
S Y
M B
O L
D E
S C
R
IP
T
IO
N D
A T
E B
Y P
L
T
C
A L
S
IG
N
Y
D A
T E
NUMBER:
REFERENCE
PLATE
SHEET
IZ
E
P L
A L
S
IG
N
D A
T E
P L
A L
E
W
H N
C
H
E C
K
D E
S
IG
N
D A
T E
F
D G
N S
P E
C
S
Y S
T
IM
E
U S
E R
N A
M E
US ARMY CORPS
OF ENGINEERS
SAVANNAH DISTRICT
.7
.0
C O
L U
M B
IA
S O
U
R O
L
IN
A
M
IN
R E
E T
S O
U
R O
L
IN
A
IN
C
S T
E V
E N
W
IL
K
IN
S
Q
U
IL
D
G
N O
V A
T
IO
OF 31
T O
B
L
IC
IT
A T
IO
S O
L
IC
IT
A T
W
H N
R
N T
R A
M O
T S
U
N O
R
R O
L
12345
C
B
A
5 4 3 2
A
B
C
D
$$DGNSPEC$$
$$SYSTIME$$
$$USERNAME$$
S Y
M B
O L
D E
S C
R
IP
T
IO
N D
A T
E B
Y P
L
A L
S
IG
N
D A
T E
NUMBER:
REFERENCE
E
P L
A L
S
IG
N
D A
T E
P L
A L
E
W
H N
C
E C
K
D E
S
IG
N
D A
T E
F
D G
N S
P E
C
S
Y S
T
IM
E
U S
E R
N A
M E
US ARMY CORPS
OF ENGINEERS
SAVANNAH DISTRICT
.7
.0
C O
L U
M B
IA
S O
U
R O
L
IN
A
R E
E T
S O
U
R O
L
IN
A
IN
C
S T
E V
E
K
IN
S
IL
D
N O
V A
T
IO
T O
B
L
IC
IT
A T
S O
L
IC
IT
A T
W
H N
R
N T
R A
M O
T S
U
N O
R
R O
L
IN
A
FINISH SCHEDULE
S P A C E
No. NAME
F L O O R B A S E NORTH WALL EAST WALL SOUTH WALL WEST WALL
FINISH FINISH FINISH FINISH FINISH FINISHCOLOR COLOR COLOR COLOR COLOR COLOR HEIGHTFINISH COLOR
C E I L I N G R E M A R K S
100 OPERATIONS CARPET CPT-2 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
100A OFFICE CARPET CPT-2 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
100B SECURE OFFICE CARPET CPT-2 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
101 CONFERENCE ROOM CARPET CPT-1 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
101A CONTROL ROOM CARPET CPT-2 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
102 COMMAND CARPET CPT-1 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
102A OFFICE CARPET CPT-1 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
102B OFFICE CARPET CPT-1 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
102C OFFICE CARPET CPT-1 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
102D OFFICE CARPET CPT-1 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
102E COMMAND CONFERENCE ROOM CARPET CPT-1 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
102F TOILET
CERAMIC
CT-1
CERAMIC
CT-2
CERAMIC/ CT-2/ CERAMIC/ CT-2/ CERAMIC/ CT-2/
GYP. BD. PNT-3 8'-6"
102G KITCHENETTE VCT VCT-1 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
103 OPERATIONS CARPET CPT-1 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
103A OFFICE CARPET CPT-1 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
103B OFFICE CARPET CPT-1 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
103C OFFICE CARPET CPT-2 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
103D STORAGE VCT VCT-1 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
104 KITCHEN VCT VCT-1 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
104A LOUNGE VCT VCT-1 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
105 MEN'S TOILET
CERAMIC
CT-1
CERAMIC
CT-2
CERAMIC/ CT-2/ CERAMIC/ CT-2/ CERAMIC/ CT-2/
GYP. BD. PNT-3 8'-6"
106 SAFETY OFFICE CARPET CPT-2 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
106A SAFETY OFFICE CARPET CPT-2 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
107 JANITOR
SEALED
---- ------ ---- PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 EXPOSED ---- ------
108 CPAC CARPET CPT-2 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
108A OFFICE CARPET CPT-2 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
108B OFFICE CARPET CPT-2 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
109 WOMEN'S TOILET
CERAMIC
CT-1
CERAMIC
CT-2
CERAMIC/ CT-2/ CERAMIC/ CT-2/ CERAMIC/ CT-2/
GYP. BD. PNT-3 8'-6"
110 ADMIN. CARPET CPT-2 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
110A OFFICE CARPET CPT-2 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
110B NETWORK VCT VCT-1 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
111 RESOURCE MANAGEMENT CARPET CPT-2 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
111A OFFICE CARPET CPT-2 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
112 CORRIDOR VCT VCT-1 RUBBER RB-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 ACT ACT-1 8'-6"
113 MECHANICAL & ELECTRICAL
SEALED
---- ------ ---- PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 PAINT PNT-1 EXPOSED ---- ------
FINISH LEGEND
TILE
TILE
TILE
CONCRETE
CONCRETE
TILE
TILE
TILE PAINT PAINT PAINT PNT-1 PNT-1 PNT-1
E. PAINT E. PAINT E. PAINT
E. PAINT E. PAINT E. PAINT
E.PNT-1 E.PNT-1 E.PNT-1
E.PNT-1E.PNT-1E.PNT-1
CERAMIC TILE WAINSCOT @ 48"H ALL WALLS/
PAINT ABOVE CERAMIC TILE WAINSCOT
CER. TILE FULL HT. EAST (WET) WALL/ ALL OTHER
WALLS CER. TILE WAINSCOT 48"H W/ PAINT ABOVE
CER. TILE FULL HT. EAST (WET) WALL/ ALL OTHER
WALLS CER. TILE WAINSCOT 48"H W/ PAINT ABOVE
LOCATION: CEILINGS
COLOR: SW7005 PURE WHITE
PNT-3 MANUFACTURER: SHERWIN WILLIAMS
LOCATION: COUNTERTOPS
COLOR: MR-2-7T BRONZE MATRIX
PL-1 MANUFACTURER: NEVAMAR
PLASTIC LAMINATE
DEMOLITION NOTES
GENERAL FINISH NOTES
PROPERTY AND LEGALLY DISPOSE OF THEM.
DEMOLISHED MATERIALS OFF GOVERNMENT
BURN DEMOLISHED MATERIALS. TRANSPORT
MATERIALS TO ACCUMULATE ON-SITE. DO NOT
MATERIALS. DO NOT ALLOW DEMOLISHED
6. PROMPTLY DISPOSE OF ALL DEMOLISHED
PATCHING AND REFINISHING.
MANNER THAT ELIMINATES EVIDENCE OF
ADJOINING CONSTRUCTION TO REMAIN IN A
AND EXTEND FINISH RESTORATION INTO
5. RESTORE EXPOSED FINISHES OF PATCHED AREAS
CONSTRUCTION IN DEMOLITION OPERATIONS.
DAMAGED SURFACES CAUSED BY ADJACENT
4. PROMPTLY PATCH AND REPAIR HOLES AND
CONSTRUCTION AND AS INDICATED.
ONLY TO THE EXTENT REQUIRED BY NEW
3. DEMOLISH AND REMOVE EXISTING CONSTRUCTION
OFFICER.
SUBMIT WRITTEN REPORT TO THE CONTRACTING
NATURE AND EXTENT OF CONFLICT. PROMPTLY
ENCOUNTERED, INVESTIGATE AND MEASURE THE
THE INTENDED FUNCTION OR DESIGN ARE
OR STRUCTURAL ELEMENTS THAT CONFLICT WITH
2. WHEN UNANTICIPATED MECHANICAL, ELECTRICAL
ITEMS TO BE REMOVED AND SALVAGED.
ITEMS TO BE REMOVED AND REINSTALLED AND
1. INVENTORY AND RECORD THE CONDITION OF
ONLY. *
ARE CALLED OUT FOR BASIS OF DESIGN
* MANUFACTURERS, COLORS AND PATTERNS
FOR CT-2, GROUT TO BE LATICRETE 23 ANTIQUE WHITE.
NOTE: FOR CT-1, GROUT TO BE LATICRETE 40 LATTE.
INSTALLED 36" ABOVE FINISHED FLOOR
11. WOOD CROWN MOULDING TO BE 6"H AND CONSTRUCTED IN TWO PIECES. WOOD BASE TO BE 6" HIGH AND CONSTRUCTED IN ONE PIECE. WOOD CHAIR RAIL TO BE
ELECTRICAL ENGINEER.
10. ELECTRICAL, TELEPHONE, COMPUTER OUTLETS, AND SWITCHES ARE TO BE ALIGNED WITH LOWER EDGES OF COVER PLATES ALIGNED AT HEIGHT AS SPECIFIED BY
9. HARDWARE AT DOORS SHALL BE COMPLETELY PROTECTED FROM PAINT. CONTRACTOR WILL BE RESPONSIBLE FOR ANY DAMAGE DONE TO HARDWARE.
MANUFACTURER'S SPECIFICATIONS.
8. WHERE WALLS HAVE BEEN REMOVED, PATCH AND REPAIR EXISTING WALLS TO RECEIVE NEW FINISH. ALL WALLS TO BE SIZED OR PRIMED AS RECOMMENDED BY
7. ABUTTING FLOOR MATERIALS AT DOORWAY SHALL ALIGN WITH CENTERLINE OF CLOSED DOOR.
MATERIALS TO GOVERNMENT.
6. AFTER RENOVATION IS COMPLETE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO THOROUGHLY CLEAN THE PREMISES AND HAUL OFF TRASH. RETURN UNUSED
5. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS.
4. IT IS THE CONTRACTOR'S RESPONSIBILITY TO BE SURE THAT THE SUB-FLOOR IS LEVEL TO ACCEPT NEW FLOORING.
3. CONTRACTOR TO SUBMIT SHOP DRAWINGS OR SAMPLES OF ALL EXACT FINISHES SPECIFIED FOR CONTRACTING OFFICER'S APPROVAL.
SEAMS SHALL BE SEALED TO PREVENT UNRAVELING.
2. CARPET SHALL BE INSTALLED BY DIRECT GLUE DOWN METHOD AS RECOMMENDED BY MANUFACTURER. SIDE SEAMS ONLY. NO CROSS SEAMS ALLOWED. ALL CARPET
1. ALL FINISHES SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS.
WOOD BASE,CROWN MOLDING & CHAIR RAIL;
SEE GENERAL FINISH NOTE 11 THIS SHEET
LOCATION: WALL ACCENT TILE
SIZE: 3"X3"
COLOR: AV98 LAVA ROCK
CT-3 MANUFACTURER: CROSSVILLE CERAMIC
LOCATION: WALL TILE
SIZE: 3"x3"
COLOR: AV94 COBBLESTONE
CT-2 MANUFACTURER: CROSSVILLE CERAMIC
LOCATION: FLOOR TILE
SIZE: 12"x12"
COLOR: VS21 PIETRA ROSA
CT-1 MANUFACTURER: CROSSVILLE CERAMIC
CERAMIC TILE
LOCATION: BASE CABINETS
COLOR: S-2069 BETHANY BEIGE
PL-2 MANUFACTURER: NEVAMAR
COLOR: GRAY #327
PT-1 MANUFACTURER: CAPITOL PARTITIONS
TOILET PARTITIONS (SOLID PLASTIC)
EXPOSED TEE GRID
GRID SYSTEM: CHICAGO METALLIC •"
COLOR: WHITE
SIZE: 24"x24"x3/4" (w/ tegular edge)
PATTERN: GLACIER #707
ACT-1 MANUFACTURER: USG
ACOUSTICAL CEILING TILE
COLOR: #51804 EARTHSTONE GRIEGE
PATTERN: STANDARD EXCELON
VCT-1 MANUFACTURER: ARMSTRONG
VINYL COMPOSITION TILE
COLOR: P194 BURNT UMBER (4")
RB-1 MANUFACTURER: ROPPE
RUBBER BASE
LOCATION: GENERAL WALLS
COLOR: SW7029 AGREEABLE GRAY
PNT-1 MANUFACTURER: SHERWIN WILLIAMS
PAINT
LOCATION: DOOR FRAMES & TRIM
COLOR: SW7031 MEGA GREIGE
PNT-2 MANUFACTURER: SHERWIN WILLIAMS
COLOR: 72709 PACIFIC
PATTERN: MERIDIAN #50872
CPT-2 MANUFACTURER: SHAW
COLOR: 509 CURFUE
PATTERN: COLLEGIATE 28 OZ.
CPT-1 MANUFACTURER: MOHAWK
CARPET
CT-2 CERAMIC
CT-2 CERAMIC
CERAMIC/ CT-2/
PAINT PNT-1
PROJECT DATA
A. PROJECT DESIGNED IN ACCORDANCE WITH:
10. Americans with Disabilities Act (ADA)
Physically Handicapped People
9. ICC / ANSI-A117.1 - 1998, Providing Accessibility and Usability for
8. ASHRAE 15 - 1994 Edition
7. ANSI / ASHRAE 62 - 1989 Edition
6. ASHRAE / IESNA 90.1 - 1989 Edition
5. North Carolina Elevator Code - Latest Edition
4. International Plumbing Code - 2003 Edition
3. International Mechanical Code - 2003 Edition
2. National Electric Code - 2002 Edition
1. International Building Code - 2003 Edition
B. BASIC REVIEW INFORMATION:
FOR BUILDING ELEMENTS:
C. FIRE RESISTIVE RATING REQUIREMENT
D. OTHER FIRE PROTECTION:
11. Fire Alarms Required:
10. Standpipes Required:
9. Sprinklers Required:
8. Smoke Barrier Required:
7. Draftstopping Required:
6. Fireblocking Required:
5. Other Special Fire Protection:
4. Mechanical Room Separation:
3. Stairway Enclosures:
2. Shaft Enclosures:
1. Exit Access Corridors:
G. MECHANICAL / PLUMBING INFORMATION:
H. ELECTRICAL INFORMATION:
E. PROJECT IN FIRE DISTRICT: Yes X No
c. Heating Load: 21.5 BTU/S.F.
d. Outside Air CFM/Person: 20 CFM/Person
Service Line Size: 3"
h. Sanitary Sewer System: Loading: GPD
e. Insulation, R value: 12.3 Ext. Walls 14.7 Roof
f. Glass: U-Factor XX SC XX Window-to-Wall Ratio XX% Window
i. Minimum Number of Plumbing Fixtures Required:
5. Other (list)
4. Drinking Fountains:
3. Showers:
2. Lavatories:
1. Water closets:
Req'd:
Req'd:
Req'd:
Req'd:
Req'd:
Provided:
Provided:
Provided:
Male:
Male:
Female:
Female:
Provided - Male:
Provided - Male:
Female:
Female:
2. If by either Utility or Owner, provide the following service information:
d. Emergency Egress Illumination, Minimum Footcandles: 1 Min.
f. Lightning Protection Provided: Yes
F. STRUCTURAL INFORMATION
DS
D1
e. Is Project in Wetlands Area: Yes No
Flood Zone: BFE: Building Lowest Elev.:
Flood Map Information: Community No.: Panel No.:
d. Is Project in Flood Plain: Yes No
4. Zoning: Local Government
3. Sewer: Local Utility
2. Water: Local Utility
1. Site Work:
c. Jurisdiction for:
b. Municipality and/or County Where Project is Located: Sunny Point, NC
a. Area of Site Developed (in acres):
1. Site Development:
Secondary Occupancy Classification: NA
2. Primary Occupancy Classification: B Business
Sprinklered: Yes No X
1 Hour Protected: Yes No X
3. Type of Construction: Type III-B
CA
Total Building Floor Area with Allowable Area Increase: 19,000
Allowable Area Increase: NA
Actual Area: 10,000 s.f. Area Allowed: 19,000
4. Building Floor Area by Design:
Total Building Height with Allowable Increase: 14'-2"
Allowable Height Increase: NA
Number of Stories: 1 Maximum Number of Stories: 4
5. Building Height: 14'-2" Maximum Allowable Height: 55'-0" immediately below is not required) part of the roof construction is 20 feet or more above any floor
(Note: Fire protection of structural-framing and decking where every
6. Roof Construction (including supporting beams and joists): 0 hour
5. Floor Construction (including supporting beams and joists): 0 hours
4. Non-bearing Interior walls and partitions: Noncombustible
Greater than 30 feet: 0 hour
10 feet to less than 30 feet: 1 hour
5 feet to less than 10 feet: 1 hour
Less than 5 feet: 1 hour
3. Non-bearing Exterior walls (based on separation distance):
Interior: 0 hours
Exterior: 2 hours
2. Bearing Walls:
1. Structural Frame (including columns, girders, trusses): 0 hours
f. Interrupting Capacity of Service Overcurrent Device: 42K
a. Overall Thermal Transfer Value (OTTV): 0.184 BTU/ nr/ft2 x F
b. Cooling Load: 333 S.F./Ton
g. Water System: # Fixture Units 76 Peak GPM 35
Service Line Size: 4" Slope: 1/8" per/ft.
g. Analysis Procedure: Equivalent Lateral Force Method will include reinforced concrete shear wall in addition to existing masonry shear wall.
bearing reinforced masonry with reinforced masonry shear wall. Seismic upgrades
f. Basic structural system and siesmic resisting system: Existing structure is load
e. Seizmic Design Category: D
d. Seizmic Use Group: I
c. Site Class: D (Assumed in accordance with IBC 1615.1.1)
b. Design Spectral Response Acceleration (1-sec Period) S = 0.22g
a. Design Spectral Response Acceleration (Short Period) S = 0.355g
Seizmic Loads:
e. Internal Pressure Coefficient = +/- 0.18
d. Exposure Catagory = C
c. Building Category = I
b. Importance Factor = 1.0
a. Basic wind speed = 140 MPH
Wind Loads (Design Loads shall conform to ASCE 7-98)
e. Ground Snow Load, Pf=10 SF
Typical Live Load = 100 PSF
b. Ground Level Floor Load:
Live Load = 20 PSF
a. Roof Loads:
Design Loads (Design Loads shall conform to 2000-IBC, UNO.)
F
IN
IS
H E
D U
L E
C O
A L
Y
IS
1. If by Owner: KVA: 300 Primary Voltage/Phase: Phase
a. Service Voltage/Phase: 208/3 Amperes: 800A
b. Service Entrance Conductors Size: 500 Quantity per Phase: 3
c. Total Connected Load KVA: 175 Estimated Demand Factor: 0.75
d. Estimated Maximum Demand KVA: 130
e. Available Fault Current in Symmetrical Amperes: Infinite
g. Type of Grounding Electrode System(s) per NEC 250-52: Cold Water Pipe, Ground Rod
Fuel: Diesel
b. Emergency Generator (if any existing): KVA: 250 Voltage/Phase: 208/3
c. Exit/Emergency Lights Backup Power: Integral Battery & Generator
Yes X No
Yes No X
Yes X No
Yes No X
Yes No X
Yes X No
NA
NA
NA
NA
1 hour
a. Service Transformer: By Utility? NO By Owner? Yes (Existing) required.)
installed by a NICET II or above. A UL Certification of completed fire alarm system is
e. Fire Alarm System: Automatic Class A; Addressable Alarm (Fire alarm system must be
BETWEEN DRAWINGS AND FIELD CONDITIONS.
DRAWINGS ARE BASED ON AS BUILT DRAWINGS PROVIDED BY THE BASE AND FIELD INVESTIGATION. NOTIFY ARCHITECT UPON DISCOVERY OF DISCREPANCIES
GENERAL NOTE (FOR ALL DRAWINGS):
DEMOLITION FLOOR PLAN
SCALE:„" = 1'-0"
E
M O
L
IT
O
P
A
D1
02 4 6 8 8
SCALE: 1/8''=1'-0''
16FT
12 16
7 7
7 7
7 7
7 7
7 7
2 11
DEMOLITION ROOF PLAN
17 17 17
20 20
3 3
9 9
EXISTING ROOF HATCH TO REMAIN
10 15
10 17
1017 2010
17 2010 17 2010
17 2010
17 2010
17 2010
AND BE REUSED
EXISTING VTR TO REMAIN
AND BE REUSED
EXISTING VTR TO REMAIN
28 28
28 28
OPENING TO BE REUSED
REMOVE EXHAUST FAN;
REMOVE ELECTRICAL OUTLET
REMOVE ELECTRICAL OUTLET
OPENING TO BE REUSED
REMOVED COMPLETE;
BOILER FLUESTACK TO BE
OPENING TO BE REUSED
REMOVE EXHAUST FAN;
REMOVE ELECTRICAL OUTLET
OPENING TO BE REUSED
REMOVE EXHAUST FAN;
ON DEMOLITION.
FOR MORE INFORMATION
AND ELEC. DRAWINGS
THIS AREA. SEE MECH.
NO FINISH WORK IN
29 30
(TURN OVER TO MOTSU INFORMATION MANAGEMENT)
REMOVE SATELLITE COMPLETE
10 17
26 26
17 2010
TO BE REUSED.
COMPLETE. OPENINGS
REMOVE EXISTING RTU
D E
M O
L
IT
12345
D
C
B
A
5 4 3 2
A
B
C
D
$$DGNSPEC$$
$$SYSTIME$$
$$USERNAME$$
S Y
M B
O L
D E
S C
R
IP
T
IO
N D
A T
E B
Y P
L
A L
S
IG
N
D A
T E
NUMBER:
REFERENCE
E
P L
A L
S
IG
N
D A
T E
P L
A L
E
W
H N
C
E C
K
D E
S
IG
N
D A
T E
F
D G
N S
P E
C
S
Y S
T
IM
E
U S
E R
N A
M E
US ARMY CORPS
OF ENGINEERS
SAVANNAH DISTRICT
.7
.0
C O
L U
M B
IA
S O
U
R O
L
IN
A
R E
E T
S O
U
R O
L
IN
A
IN
C
S T
E V
E
K
IN
S
IL
D
N O
V A
T
IO
N
NOT TO SCALE
KEY PLAN
T O
B
L
IC
IT
A T
S O
L
IC
IT
A T
W
H N
R
N T
R A
M O
T S
U
N O
R
R O
L
IN
A
REMOVE EXISTING STOREFRONT COMPLETE.
DEMOLITION NOTES
DEMOLITION NOTES
25 REMOVE EXISTING METAL COPING COMPLETE.
GENERAL NOTES
DEMOLITION LEGEND
BE REMOVED
EXISTING CONSTRUCTION TO
EXISTING CONSTRUCTION TO REMAIN
# KEYED DEMOLITION NOTE
DEMOLISH EXISTING STUD WALL.
NEW FINISH.
REMAIN INTACT - PREPARE FRAME TO RECEIVE
REMOVE EXISTING DOOR & TRANSOM, FRAME TO
WINDOW, FRAME, AND PRECAST SILL.
COMPLETE. PREPARE OPENING TO RECEIVE NEW
REMOVE EXISTING WINDOW, FRAME, AND CMU SILL
HARDWARE COMPLETE.
REMOVE EXISTING EXTERIOR DOOR, FRAMING AND
PENETRATION.
REMOVE PORTION OF EXISTING CMU WALL FOR NEW
AND HARDWARE COMPLETE.
REMOVE EXISTING INTERIOR DOOR , FRAMING,
SURFACE TO RECEIVE SCHEDULED FLOORING.
REMOVE CARPET COMPLETE. PREPARE FLOOR
TO RECEIVE SCHEDULED FLOORING.
REMOVE VCT COMPLETE. PREPARE FLOOR SURFACE
SCHEDULED FINISHES.
TILE. PREPARE FLOOR AND WALLS TO RECEIVE
COMPLETE. REMOVE CERAMIC FLOOR AND WALL
PARTITIONS, COUNTERS, AND ACCESSORIES
REMOVE TOILETS, SINKS, URINALS, TOILET
REMOVE SINK COMPLETE.
REMOVE MOP SINK COMPLETE.
NEW FINISH.
REMAIN INTACT. PREPARE FRAME TO RECEIVE
REMOVE DOOR AND HARDWARE COMPLETE. FRAME TO
ON DEMOLITION AND REUSE OF ITEMS.
SEE ELECTRICAL DWGS. FOR MORE INFORMATION
ANY OTHER CEILING MOUNTED ITEMS COMPLETE.
COMPLETE. REMOVE LIGHTS, DIFFUSERS, AND
REMOVE GRID, HANGERS, TIES, & CEILING TILES
NEW DOOR.
REMOVE PORTION OF EXISTING STUD WALL FOR
THE FIXTURES AND UNITS.
REMOVE ALL WIRING AND CONDUITS LEADING TO
REMOVE EXISTING LIGHT FIXTURES COMPLETE.
WITH 8" CMU.
COMPLETE. PREPARE OPENING TO BE FILLED
REMOVE EXISTING WINDOW, FRAME AND CMU SILL
28 REMOVE INTERNAL ROOF DRAINS COMPLETE.
REMOVE EXISTING LADDER TO ROOF.
COMPLETE.
REMOVE EXISTING BUILT-UP ROOF TO METAL DECK
COMPLETE.
REMOVE BOOKCASE, SHELVING OR CASEWORK
AND PIPES COMPLETE.
REMOVE GYP. BD. CEILING, LIGHT FIXTURES,
REMOVE DRINKING FOUNTAIN.
DEMOLISH EXISTING CMU WALL.
INFORMATION MANAGEMENT.
ITEMS ARE TO BE TURNED OVER TO MOTSU
ASSOCIATED EQUIPMENT COMPLETE. THESE
REMOVE OVERHEAD PROJECTOR AND ALL
WIRING TO THE CONTROL ROOM.
IS TO REMAIN WITH EXISTING CONDUIT AND
CEILING MOUNTED REMOTE MOUSE EQUIPMENT
TO THE GOVERNMENT.
ARE TO BE REMOVED AND TURNED OVER
REMAINING ITEMS IN THE BUILDING WHICH
DEMOLITION BEGINS TO VERIFY ANY
BUILDING WITH THE GOVERNMENT BEFORE
6. CONTRACTOR IS TO WALK THROUGH THE
THE FINISHED SURFACE.
RECOMMENDATIONS FOR INSTALLATION TO
REINSTALLED PER THE MANUFACTURER'S
UPON COMPLETION, THE DEVICES ARE TO BE
APPLICATION OF SHOTCRETE AND STUCCO.
BE LOOSENED FROM THE WALL TO ALLOW FOR
TO REMAIN ON THE EXTERIOR FACADE IS TO
5. ANTENNA, ELECTRICAL DEVICE OR CONDIUT
INFORMATION MANAGEMENT.
AND TURNED OVER TO MOTSU
EQUIPMENT ARE TO BE REMOVED
4. ALL SATELLITES AND ASSOCIATED
DESIGN STANDARDS.
PROTECTION REQUIREMENTS AND BASE
GROUND COVER TO MATCH FORCE
BUILDING, INSTALL NEW 12" SHRUBS AND
DEMOLITION. UPON COMPLETION OF THE
BUILDING ARE TO BE REMOVED DURING
3. TREES AND SHRUBS SURROUNDING THE
DIMENSIONS.
VERIFYING ALL EXISTING CONDITIONS AND
CONTRACTOR IS RESPONSIBLE FOR FIELD
CONDITIONS SHOWN ON DRAWINGS.
THERE ARE ANY DEVIATIONS FROM EXISTING
2. NOTIFY GOVERNMENT IMMEDIATELY IF
ON EXTENT OF DEMOLITION AND RENOVATION.
ELECTRICAL PLANS FOR MORE INFORMATION
1. SEE STRUCTURAL, MECHANICAL AND
COUNTER TO FLOOR TO PREPARE FOR NEW DOOR.
AND HARDWARE COMPLETE. REMOVE CMU BELOW
REMOVE EXISTING COILING COUNTER SHUTTER
PAINT.
PREPARE DOOR AND FRAME TO RECEIVE NEW
INTACT. PREPARE DOOR FOR NEW HARDWARE.
EXISTING SECURE DOOR AND FRAME TO REMAIN
COMPLETE.
REMOVE MECHANICAL AND ELECTRICAL EQUIPMENT
DRAWINGS FOR MORE INFORMATION.
ELECTRICAL FLOOR BOXES. SEE ELECTRICAL
TRENCH FLOOR SLAB AS REQUIRED FOR NEW
DRAWINGS FOR MORE INFORMATION.
PLUMBING WASTE LINES. SEE MECHANICAL
TRENCH FLOOR SLAB AS REQUIRED FOR NEW
PANEL TO THE RECEPTACLE.
THROUGHOUT THE ENTIRE CIRCUIT FROM THE
CIRCUIT PANEL. NEW WIRING SHALL BE PROVIDED
CONDUIT ROUTED BACK TO THE NEW BRANCH
LOCATION ABOVE ACCESSIBLE CEILING AND NEW
INTERCEPTED AT THE NEAREST POSSIBLE
E-9. THE EXISTING CONDUIT SHALL BE
RECEPTACLE LOCATION AS SHOWN ON DRAWING
BE REUSED IF LOCATED WITHIN 12" OF THE NEW
AND OUTLET BOXES WITHIN EXISTING WALLS CAN
AND ASSOCIATED CONDUIT AND WIRING. CONDUIT
DEMO AND REMOVE ALL EXISTING RECEPTACLES
D2
SOUTH ELEVATION
DEMOLITION
SCALE:„" = 1'0"
EAST ELEVATION
NORTH ELEVATION
WEST ELEVATION
16FT
3 2
1 1
3 3
3 3
3 3
4 4 4 4
25 25
26 26
E L
E V
A T
IO
N S
D E
M O
L
IT
T E
R
IO
R
12345
D
C
B
A
5 4 3 2
A
B
C
D
$$DGNSPEC$$
$$SYSTIME$$
$$USERNAME$$
S Y
M B
O L
D E
S C
R
IP
T
IO
N D
A T
E B
Y P
L
A L
S
IG
N
D A
T E
NUMBER:
REFERENCE
E
P L
A L
S
IG
N
D A
T E
P L
A L
E
W
H N
C
E C
K
D E
S
IG
N
D A
T E
F
D G
N S
P E
C
S
Y S
T
IM
E
U S
E R
N A
M E
US ARMY CORPS
OF ENGINEERS
SAVANNAH DISTRICT
.7
.0
C O
L U
M B
IA
S O
U
R O
L
IN
A
R E
E T
S O
U
R O
L
IN
A
IN
C
S T
E V
E
K
IN
S
IL
D
N O
V A
T
IO
N
NOT TO SCALE
T O
B
L
IC
IT
A T
S O
L
IC
IT
A T
W
H N
R
N T
R A
M O
T S
U
N O
R
R O
L
IN
A
+0'-0"
FINISH FLOOR
REMOVE EXISTING STOREFRONT COMPLETE.
DEMOLITION NOTES
DEMOLITION NOTES
25 REMOVE EXISTING METAL COPING COMPLETE.
GENERAL NOTES
DEMOLITION LEGEND
BE REMOVED
EXISTING CONSTRUCTION TO
EXISTING CONSTRUCTION TO REMAIN
# KEYED DEMOLITION NOTE
DEMOLISH EXISTING STUD WALL.
NEW FINISH.
REMAIN INTACT - PREPARE FRAME TO RECEIVE
REMOVE EXISTING DOOR & TRANSOM, FRAME TO
WINDOW, FRAME, AND PRECAST SILL.
COMPLETE. PREPARE OPENING TO RECEIVE NEW
REMOVE EXISTING WINDOW, FRAME, AND CMU SILL
HARDWARE COMPLETE.
REMOVE EXISTING EXTERIOR DOOR, FRAMING AND
PENETRATION.
REMOVE PORTION OF EXISTING CMU WALL FOR NEW
AND HARDWARE COMPLETE.
REMOVE EXISTING INTERIOR DOOR , FRAMING,
SURFACE TO RECEIVE SCHEDULED FLOORING.
REMOVE CARPET COMPLETE. PREPARE FLOOR
TO RECEIVE SCHEDULED FLOORING.
REMOVE VCT COMPLETE. PREPARE FLOOR SURFACE
SCHEDULED FINISHES.
TILE. PREPARE FLOOR AND WALLS TO RECEIVE
COMPLETE. REMOVE CERAMIC FLOOR AND WALL
PARTITIONS, COUNTERS, AND ACCESSORIES
REMOVE TOILETS, SINKS, URINALS, TOILET
REMOVE SINK COMPLETE.
REMOVE MOP SINK COMPLETE.
NEW FINISH.
REMAIN INTACT. PREPARE FRAME TO RECEIVE
REMOVE DOOR AND HARDWARE COMPLETE. FRAME TO
ON DEMOLITION AND REUSE OF ITEMS.
SEE ELECTRICAL DWGS. FOR MORE INFORMATION
ANY OTHER CEILING MOUNTED ITEMS COMPLETE.
COMPLETE. REMOVE LIGHTS, DIFFUSERS, AND
REMOVE GRID, HANGERS, TIES, & CEILING TILES
NEW DOOR.
REMOVE PORTION OF EXISTING STUD WALL FOR
THE FIXTURES AND UNITS.
REMOVE ALL WIRING AND CONDUITS LEADING TO
REMOVE EXISTING LIGHT FIXTURES COMPLETE.
WITH 8" CMU.
COMPLETE. PREPARE OPENING TO BE FILLED
REMOVE EXISTING WINDOW, FRAME AND CMU SILL
28 REMOVE INTERNAL ROOF DRAINS COMPLETE.
REMOVE EXISTING LADDER TO ROOF.
COMPLETE.
REMOVE EXISTING BUILT-UP ROOF TO METAL DECK
COMPLETE.
REMOVE BOOKCASE, SHELVING OR CASEWORK
AND PIPES COMPLETE.
REMOVE GYP. BD. CEILING, LIGHT FIXTURES,
REMOVE DRINKING FOUNTAIN.
DEMOLISH EXISTING CMU WALL.
INFORMATION MANAGEMENT.
ITEMS ARE TO BE TURNED OVER TO MOTSU
ASSOCIATED EQUIPMENT COMPLETE. THESE
REMOVE OVERHEAD PROJECTOR AND ALL
WIRING TO THE CONTROL ROOM.
IS TO REMAIN WITH EXISTING CONDUIT AND
CEILING MOUNTED REMOTE MOUSE EQUIPMENT
TO THE GOVERNMENT.
ARE TO BE REMOVED AND TURNED OVER
REMAINING ITEMS IN THE BUILDING WHICH
DEMOLITION BEGINS TO VERIFY ANY
BUILDING WITH THE GOVERNMENT BEFORE
6. CONTRACTOR IS TO WALK THROUGH THE
THE FINISHED SURFACE.
RECOMMENDATIONS FOR INSTALLATION TO
REINSTALLED PER THE MANUFACTURER'S
UPON COMPLETION, THE DEVICES ARE TO BE
APPLICATION OF SHOTCRETE AND STUCCO.
BE LOOSENED FROM THE WALL TO ALLOW FOR
TO REMAIN ON THE EXTERIOR FACADE IS TO
5. ANTENNA, ELECTRICAL DEVICE OR CONDIUT
INFORMATION MANAGEMENT.
AND TURNED OVER TO MOTSU
EQUIPMENT ARE TO BE REMOVED
4. ALL SATELLITES AND ASSOCIATED
DESIGN STANDARDS.
PROTECTION REQUIREMENTS AND BASE
GROUND COVER TO MATCH FORCE
BUILDING, INSTALL NEW 12" SHRUBS AND
DEMOLITION. UPON COMPLETION OF THE
BUILDING ARE TO BE REMOVED DURING
3. TREES AND SHRUBS SURROUNDING THE
DIMENSIONS.
VERIFYING ALL EXISTING CONDITIONS AND
CONTRACTOR IS RESPONSIBLE FOR FIELD
CONDITIONS SHOWN ON DRAWINGS.
THERE ARE ANY DEVIATIONS FROM EXISTING
2. NOTIFY GOVERNMENT IMMEDIATELY IF
ON EXTENT OF DEMOLITION AND RENOVATION.
ELECTRICAL PLANS FOR MORE INFORMATION
1. SEE STRUCTURAL, MECHANICAL AND
COUNTER TO FLOOR TO PREPARE FOR NEW DOOR.
AND HARDWARE COMPLETE. REMOVE CMU BELOW
REMOVE EXISTING COILING COUNTER SHUTTER
PAINT.
PREPARE DOOR AND FRAME TO RECEIVE NEW
INTACT. PREPARE DOOR FOR NEW HARDWARE.
EXISTING SECURE DOOR AND FRAME TO REMAIN
COMPLETE.
REMOVE MECHANICAL AND ELECTRICAL EQUIPMENT
DRAWINGS FOR MORE INFORMATION.
ELECTRICAL FLOOR BOXES. SEE ELECTRICAL
TRENCH FLOOR SLAB AS REQUIRED FOR NEW
DRAWINGS FOR MORE INFORMATION.
PLUMBING WASTE LINES. SEE MECHANICAL
TRENCH FLOOR SLAB AS REQUIRED FOR NEW
PANEL TO THE RECEPTACLE.
THROUGHOUT THE ENTIRE CIRCUIT FROM THE
CIRCUIT PANEL. NEW WIRING SHALL BE PROVIDED
CONDUIT ROUTED BACK TO THE NEW BRANCH
LOCATION ABOVE ACCESSIBLE CEILING AND NEW
INTERCEPTED AT THE NEAREST POSSIBLE
E-9. THE EXISTING CONDUIT SHALL BE
RECEPTACLE LOCATION AS SHOWN ON DRAWING
BE REUSED IF LOCATED WITHIN 12" OF THE NEW
AND OUTLET BOXES WITHIN EXISTING WALLS CAN
AND ASSOCIATED CONDUIT AND WIRING. CONDUIT
DEMO AND REMOVE ALL EXISTING RECEPTACLES
+0'-0"
FINISH FLOOR
+0'-0"
FINISH FLOOR
+0'-0"
FINISH FLOOR
ROOF PLAN
METAL COPING DETAIL
A3
SCALE:1•" = 1'-0"
3 ROOF DRAIN DETAIL
SCALE:3" = 1'-0"
T A
IL
S
R O
A N
A3
FOR MORE INFORMATION
SEE DETAIL 2/A3 AND SHEET M2
ROOF DRAIN (TYP. AT 4 LOCATIONS)-
WALKWAY PADS
EXISTING ROOF HATCH
MORE INFORMATION
SEE MECH. DWGS. FOR
CONDENSER -
MORE INFORMATION
SEE MECH. DWGS. FOR
CONDENSER -
FOR MORE INFORMATION
OPENINGS; SEE SHEET M5
NEW RTU - REUSE EXISTING
FLUE STACK TO BE REUSED
EXISTING BOILER
RD
RD
OVERFLOW SCUPPER
SEE DETAIL 4/A3 (TYP. AT 4 LOCATIONS)
NEW 12" x 4" OVERFLOW SCUPPER -
VENT THRU ROOF
NEW ROOF SLOPE AT‚" PER FOOT.
CONTRACTOR TO FIELD VERIFY AND PROVIDE
NOTE: EXISTING ROOF STRUCTURE SLOPES.
RD
RD
VTR
(REUSE OPENING)
EXHAUST FAN
ROOF PENETRATION
LADDER IN ROOM 107
A1
16FT
MORE INFORMATION
SEE SHEET E9 FOR
TV SATELLITE-
MORE INFORMATION
SEE SHEET E9 FOR
TV ANTENNA-
ROOF DETAIL
A4
ROOF DETAIL
PH. # 1.866.766.3727)
ROOF SCREEN MANUFACTURING
(BASIS OF DESIGN -
8'-0" HIGH METAL SCREEN WALL
12345
D
C
B
A
5 4 3 2
A
B
C
D
$$DGNSPEC$$
$$SYSTIME$$
$$USERNAME$$
S Y
M B
O L
D E
S C
R
IP
T
IO
N D
A T
E B
Y P
L
A L
S
IG
N
D A
T E
NUMBER:
REFERENCE
E
P L
A L
S
IG
N
D A
T E
P L
A L
E
W
H N
C
E C
K
D E
S
IG
N
D A
T E
F
D G
N S
P E
C
S
Y S
T
IM
E
U S
E R
N A
M E
US ARMY CORPS
OF ENGINEERS
SAVANNAH DISTRICT
.7
.0
C O
L U
M B
IA
S O
U
R O
L
IN
A
R E
E T
S O
U
R O
L
IN
A
IN
C
S T
E V
E
K
IN
S
IL
D
N O
V A
T
IO
N
NOT TO SCALE
T O
B
L
IC
IT
A T
S O
L
IC
IT
A T
W
H N
R
N T
R A
M O
T S
U
N O
R
R O
L
IN
A
4" CANT
FLASHING
METAL COUNTER
ƒ" ƒ"
6"
TO WOOD BLOCKING CONT
CONT. METAL CLEAT NAIL
WOOD BLOCKING
METAL CLEAT NAIL TO
METAL COPING
METAL DECK
EXISTING
EXISTIING 8" CMU
TO EXISTING 8" CMU
WOOD BLOCKING ANCHORED
3" SHOT-CRETE
+/- 1' -0"
PRESLOPED RIGID INSULATION
ATTACHED TO METAL DECK
PRESSURE TREATED WOOD BLOCKING
ALL SIDES TYPICAL
SEAL OR SOLDER
METAL FLASHING
SEAL ALL SIDES
4"
ALL SIDES
SEAL OR SOLDER
FLAT LOCK SEAM
EXISTING 8" CMU
EXISTING METAL DECK
METAL COPING
INSULATION
1•" RIGID
MEMBRANE ADHERED
SINGLE PLY
MEMBRANE
AND OVER SINGLE-PLY
COUNTER FLASHING
RUN UNDER METAL
BASE FLASHING TO
SINGLE-PLY MEMBRANE
FLASHING STRIP - HOT AIR WELD
STUCCO SKIMCOAT
UNDER FLASHING STRIP
METAL SCUPPER TO EXTEND
UNDER METAL COPING
SINGLE-PLY MEMBRANE TO RUN
SEE ELEV. FOR HEIGHT
METAL OVERFLOW SCUPPER
STUCCO SKIMCOAT
4"MIN
12" MIN
INSULATION
1•" RIGID
PLUMBING VENT
METAL DECK
SINGLE-PLY MEMBRANE
ADHERED
MEMBRANE FLASHING,
HOT-AIR WELD
PIPE SEAL
PRE-MOLDED
MASTIC SEALANT
WATER CUT-OFF
CLAMPING RING
STAINLESS STEEL
FLASHING
SEALANT UNDER MEMBRANE
MANUFACTURER'S RECOMMENDED
SET PIPE SEAL IN
DRAIN STRAINER
CLAMPING RING
HOT-AIR WELD
ADHERED
MEMBRANE FLASHING,
FASTENED AS REQUIRED
TAPERED EDGE SECURELY
1•" RIGID INSUL.
ADHERED
MEMBRANE
SINGLE-PLY
EXISTING METAL DECK
AT CLAMPING RING
SEALANT UNDER MEMBRANE
11" w/…" A.BOLTS
@ 5~0" O.C.MAX.
STL.BRACKET
4"x10"x…"x4"
STL.FLAT BAR
2"x…" CONT.
TO FLAT BAR
@ 12" O.C. - WELD
ƒ"o STL.BARS
LADDER PARTS
PAINT ALL STEEL
3/4" = 1'-0"
LADDER
EXISTING FINISHED FLOOR
EXISTING ROOF HATCH
8" CMU
EXISTING
8" CMU
EXISTING
F I
E
V
R I
F Y
SEALANT
SET IN NON-HARDENING
1"x‚" DRAW BAND
METAL HOOD
PIPE SIZE VARIES
METAL PITCH DAM
BLOCKING
TO TRT.WOOD
FASTEN FLANGE
ROOF INSULATION
1•" METAL DECK
ROOF PENETRATION
SAME WEIGHT AS FOR
HOOD & FLASHING TO BE
ADHERED
SINGLE-PLY MEMBRANE
ADHERED
MEMBRANE FLASHING,
HOT-AIR WELD
2"2"6"
RIGID INSULATION
STUCCO SKIMCOAT
(BEYOND)
PRECAST VENEER
SHEATHING
EXTERIOR PLYWOOD
@ 16" O.C.
6" METAL STUDS
SLOPE •" TO DRAIN
STUCCO SKIMCOAT
AS REQUIRED
WOOD BLOCKING
FOR MORE INFO.
SEE STRUCT. DWGS.
STEEL BEAM-
EXISTING PARAPET
3" SHOT-CRETE
STUCCO SKIMCOAT
FOR MORE INFO.
SEE STRUCT. DWGS.
STEEL BEAM-
MEMBRANE ADHERED
SINGLE PLY
STEEL TUBE
AND SIT FLUSH WITH
EXISTING PARAPET
CANT TO COVER
6" METAL STUDS
2"2"
(BEYOND)
PRECAST VENEER
"(HOT AIR WELD)
SINGLE-PLY MEMBRANE
PANELS AND OVER
RUN UNDER METAL
BASE FLASHING TO
STUCCO SKIMCOAT
SEALANT
A
4.1
8.1
7.1
8.1
8.0
4.0
8.1
C
A
A B
8.0 8.0
8.1
SOUTH ELEVATION
EAST ELEVATION
NORTH ELEVATION
WEST ELEVATION
16FT
3 2
A
A A A A A
A
9.2
9.2
9.2.1
9.2
9.2.1
9.2
9.2
9.2
112 112A
112C 112B
2"
ELEVATION DETAIL
SCALE:‚" = 1'-0"
9.2.1
5'-7" 5'-4" 2'-8" 5'-4" 2'-4"2'-4" 5'-4" 5'-4" 2'-4"2'-4" 5'-4" 3'-4" 5'-4" 2'-4"2'-4" 5'-4" 2'-8" 5'-4" 5'-7"
4.1 4.1 4.1
4'-3"7'-7"7'-6"7'-7"7'-7"7'-6"7'-7"7'-7"7'-6"7'-7"4'-3"
4.1 4.1 4.1
STUCCO SMOOTH FINISH
STUCCO FINE SAND FINISH
PRECAST SILL
4.1
4.1 4.1
METAL COPING
7.1
7.17.1
7.0
7.0
16.0
16.0
16.1
16.1
2.0
2.0
9.2.14.1
2.0
2.0
8.0
8.1 8.1 8.1 8.1 8.1 8.1
8.1 8.1
STUCCO FINE SAND FINISH
STUCCO SMOOTH FINISH
WALL SECTION
SCALE:•" = 1'-0"
19'-7"14'-3"2'-8"13'-7"4'-4"25'-8"4'-4"19'-7"2'-8"14'-3"19'-7"
19'-7"14'-3"2'-8"19'-7"4'-4"25'-8"4'-4"13'-7"2'-8"14'-3"19'-7"
WALL SECTION
SCALE:•" = 1'-0"
9.2.1
16.1
9.2.1
4.6
4.2
4.0
4.6 4.2
4.0
4.64.6
+14'-2"
TOP OF PARAPET
+16'-2"
TOP OF PARAPET
+22'-8"
TOP OF CORNICE
+14'-2"
TOP OF PARAPET
+16'-2"
TOP OF PARAPET
+22'-8"
TOP OF CORNICE
+14'-2"
TOP OF PARAPET
+14'-2"
TOP OF PARAPET
4.0
4.6 4.2
4.0
4.6 4.2
16.1
4.6
4.2
9.2.1
9.2.1
PRECAST CAP
4.0
4.6 4.2
4.0
4.6 4.2
4.6 4.2
7.0 7.0
7.0 7.0
4.2
4.3
5.0
3.0
4.2
4.3
3.0
4.6
9.2
TO REMAIN
STRUCTURE
EXTISTING
7.3.1
7.3.3
7.3.2
7.3
7.3.2
6.0
5.1
6.1
9.0 (6" @ 16" o.c.)
9.3
7.4
@ 16" o.c.)
9.0 (2 1/2"
9.1
9.44.2
4.3
4.5
4.0
3.0
H4
A5
S4
A5
9.3
7.4
@ 16" o.c.)
9.0 (2 1/2"
9.4
8.1
TO REMAIN
STRUCTURE
EXTISTING
7.3.1
7.3.3
7.3.2
7.3
7.3.2
5.1
6.1
9.0 (6" @ 16" o.c.)
6.0
A3
7"
W A
C T
IO
T E
R
E V
A T
IO
16.0 16.0 16.0 16.0
16.0 16.0 16.0 16.0
RECAULK FRAME/WALL JOINT.
REPAINT DOOR, FRAME AND LOUVER.
16.0
7.2 7.2
7.2 7.2
7.2
7.2
5.1 6
12345
D
C
B
A
5 4 3 2
A
B
C
D
$$DGNSPEC$$
$$SYSTIME$$
$$USERNAME$$
S Y
M B
O L
D E
S C
R
IP
T
IO
N D
A T
E B
Y P
L
A L
S
IG
N
D A
T E
NUMBER:
REFERENCE
E
P L
A L
S
IG
N
D A
T E
P L
A L
E
W
H N
C
E C
K
D E
S
IG
N
D A
T E
F
D G
N S
P E
C
S
Y S
T
IM
E
U S
E R
N A
M E
US ARMY CORPS
OF ENGINEERS
SAVANNAH DISTRICT
.7
.0
C O
L U
M B
IA
S O
U
R O
L
IN
A
R E
E T
S O
U
R O
L
IN
A
IN
C
S T
E V
E
K
IN
S
IL
D
N O
V A
T
IO
N
NOT TO SCALE
T O
B
L
IC
IT
A T
S O
L
IC
IT
A T
W
H N
R
N T
R A
M O
T S
U
N O
R
R O
L
IN
A
+0'-0"
FINISH FLOOR
Schedule on Sheet A5)
8.1 ALUMINUM WINDOW SYSTEM (see Window
(see Door Schedule and details on Sheet A5)
8.0 ALUMINUM ENTRANCE / STOREFRONT SYSTEM
16.1 ENTRY KEYPAD (see Electrical Drawings)
16.0 EXTERIOR LIGHT FIXTURE (see Electrical Drawings)
BUILDING
2.0 APPROXIMATE FINISH GRADE - SLOPE AWAY FROM
ELEVATION/SECTION KEY NOTES:
GENERAL NOTES:
AND DRAWINGS.
DISCREPANCIES BETWEEN EXISTING CONDITIONS
NOTIFY ARCHITECT IMMEDIATELY UPON
2. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS.
GUIDELINES
EXISTING INSTALLATION'S BUILDING COLOR
1. COLOR OF STUCCO FINISHES TO MATCH
5.2 STRUCTURAL STEEL LINTEL
5.1 STRUCTURAL STEEL BEAM (see Structural Drawings)
5.0 STRUCTURAL STEEL COLUMN (see Structural Drawings)
6.1 EXTERIOR PLYWOOD SHEATHING
6.0 WOOD BLOCKING
3.0 SHOT-CRETE (See Structural Drawings for more information)
4.6 PRECAST CAP
@ 16" O.C. with CELLULAR VENT
4.5 THROUGH-WALL FLASHING with HEAD JOINT WEEPS
@ SPACING SPECIFIED IN SECTION
4.4 ADJUSTABLE MASONRY VENEER ANCHORS
4.3 HORIZONTAL JOINT REINFORCING @ 16" O.C.
4.2 SPLIT FACE CMU VENEER
4.1 CONTROL JOINT -(see sheet S1 for more information)
4.0 PRECAST SILL - (see details on sheet A5)
9.4 WALL BASE AS SCHEDULED
9.3 5/8" GYPSUM BOARD
9.2.1 SYNTHETIC STUCCO SCORELINE
9.2 SYNTHETIC STUCCO SKIMCOAT
9.1 CEILING SYSTEM AS SCHEDULED
9.0 METAL STUDS (size and spacing as indicated)
7.4 BATT INSULATION
7.3.3 FLASHING
7.3.2 CANT STRIP
7.3.1 RIGID INSULATION
7.3 SINGLE-PLY MEMBREANE ROOFING
ph. # 1.866.766.3727)
(Basis of Design - Roof Screen Manufacturing
7.2 METAL SCREEN WALL
7.1 4" x 12" OVERFLOW SCUPPER
7.0 METAL COPING (see details on Sheet A3)
+0'-0"
FINISH FLOOR
+0'-0"
FINISH FLOOR
+0'-0"
FINISH FLOOR
+10'-8"
+12'-8"
+14'-0"
+10'-8"
+12'-8"
+14'-0"
A5
01 2 3 4 4
SCALE: 1/4''=1'-0''
A
T A
IL
S
D O
D
P E
S
3'-0"
1ƒ" THICK
FLUSH DOORS
WOOD DOOR, NO LABEL 2
3'-0"
1ƒ" THICK
FLUSH DOORS
WOOD DOOR, NO LABEL
4'-6"
2"3'-0"2"1'-0"2"
B
EXTERIOR
ALUM. FRAME
H3
J3
3 ALUM. DOORS, NO LABEL
6"2'-0"6"
3'-0"
A H.M. FRAME
2"DOOR WIDTH2"
D O
T
H E
D
AS SCHED.
INTERIOR
DOOR TYPES
H1 H2
J1
J2
H2 AND J2 ARE AT GYP. BD. OPENINGS.
NOTE: H1 AND J1 ARE AT MASONRY OPENINGS.
INSUL. & LAM. GLASS INSUL. & LAM. GLASS
6"2'-0"6"
3'-0"
TEMP. GLASS
WD. DOOR, NO LABEL 5
6'-0"
1…" THICK
BIFOLD DOORS
WOOD DOOR, NO LABEL
1'-6"1'-6"1'-6"1'-6"
S3
FRAME TYPES
2'-0"
1ƒ" THICK
FLUSH DOORS
WOOD DOOR, NO LABEL 7
3'-0"
1ƒ" THICK
FLUSH DOORS
METAL DOOR, NO LABEL 8
3'-0"
1ƒ" THICK
FLUSH DOORS
METAL DOOR, NO LABEL
12345
D
C
B
A
5 4 3 2
A
B
C
D
$$DGNSPEC$$
$$SYSTIME$$
$$USERNAME$$
S Y
M B
O L
D E
S C
R
IP
T
IO
N D
A T
E B
Y P
L
A L
S
IG
N
D A
T E
NUMBER:
REFERENCE
E
P L
A L
S
IG
N
D A
T E
P L
A L
E
W
H N
C
E C
K
D E
S
IG
N
D A
T E
F
D G
N S
P E
C
S
Y S
T
IM
E
U S
E R
N A
M E
US ARMY CORPS
OF ENGINEERS
SAVANNAH DISTRICT
.7
.0
C O
L U
M B
IA
S O
U
R O
L
IN
A
R E
E T
S O
U
R O
L
IN
A
IN
C
S T
E V
E
K
IN
S
IL
D
N O
V A
T
IO
T O
B
L
IC
IT
A T
S O
L
IC
IT
A T
W
H N
R
N T
R A
M O
T S
U
N O
R
R O
L
IN
A
5'-4"
H4
S4
J4
A
ALUM. FRAME
EXTERIOR B
ALUM. FRAME
EXTERIOR C
ALUM. FRAME
EXTERIOR
30'-0"
2"2'-9"2"2'-10"2"2'-10"2"2'-10"2"2'-10"2"2'-10"2"2'-10"2"2'-10"2"2'-10"2"2'-9"2"
NOTE: ALL EXTERIOR WINDOWS TO HAVE LAMINATED AND INSULATED GLAZING
WINDOW TYPES
48'-0"
2"2'-5"2"2'-5"2"
H4
J4
H4
J4
S4
D
H.M. FRAME
INTERIOR
VIEW GLASS
ONE-WAY
INSULATED GLAZING
LAMINATED &
INSULATED GLAZING
LAMINATED &
INSULATED GLAZING
LAMINATED &
H5
J5
S5
2"3'-8"2"
4'-0"
2"2'-9"2"2'-10"2"2'-10"2"2'-10"2"2'-10"2"2'-10"2"2'-10"2"2'-10"2"2'-10"2"2'-10"2"2'-10"2"2'-10"2"2'-10"2"2'-10"2"2'-10"2"2'-9"2"
S4
(EA. SIDE)
SEALANT
CHANNEL
MTL.RUNNER
H.M.FRAME
D O
I
G H
T
H E
D U
L E
D
†" GYP.BD.
WHERE REQUIRED
BATT INSULATION
8~0" A.F.F.
†" GYP. BD.
STUD @ 16" O.C.
1•" METAL
†" GYP. BD.
‡" HAT CHANNEL
CMU WALL
EXISTING 8"
TYP.
SEALANT EACH SIDE
8ƒ"
2•" 1•"
(EA. SIDE)
SEALANT
PER JAMB
3 ANCHOR CLIPS
H.M.FRAME
BACK TO BACK
DOUBLE STUDS
†" GYP.BD.
†" GYP. BD.
STUD @ 16" O.C.
1•" METAL
†" GYP. BD.
‡" HAT CHANNEL
CMU WALL
EXISTING 8"
2•" 1•"
H E
D
D O
I
D T
JAMB DETAIL
J1
TYP.
SEALANT EACH SIDE
HEAD DETAIL
H1
HEAD DETAIL
H2
JAMB DETAIL
J2
@ NEW FRAME
GROUT SOLID
NEW H.M.FRAME-
EXISTING OR
1•"4"6†"
AS SCHEDULED
ALUMINUM STOREFRONT
HGT. AS SCHED.
EXTERIOR DOORS
HEAD DETAIL @
H3
SCALE:1•" = 1'-0"
EXTERIOR STOREFRONT
SILL DETAIL @
S3
SCALE:1•" = 1'-0"
EXTERIOR DOORS
JAMB DETAIL @
J3
SCALE:1•" = 1'-0"
(TYP.)
CORNER BEAD
IN ALUMINUM FRAME
INSULATED GLASS
LAMINATED AND
CMU WALL
EXISTING 8"
†" GYP. BD.
‡" HAT CHANNEL
IN ALUMINUM FRAME
INSULATED GLASS
LAMINATED AND
CMU WALL
EXISTING 8"
†" GYP. BD.
H E
D
D O
D T
H
H E
D
D O
D T
H
IN ALUMINUM FRAME
INSULATED GLASS
LAMINATED AND
(EACH SIDE)
SEALANT
EACH SIDE TYP.
SEALANT & BACKER ROD
EACH SIDE TYP.
SEALANT & BACKER ROD
WINDOW
HEAD DETAIL @
H4
SCALE:1•" = 1'-0"
WINDOW
JAMB DETAIL @
J4
SCALE:1•" = 1'-0"
IN ALUMINUM FRAME
INSULATED GLASS
LAMINATED AND
CMU WALL
EXISTING 8"
IN ALUMINUM FRAME
INSULATED GLASS
LAMINATED AND
CMU WALL
EXISTING 8"
EACH SIDE TYP.
SEALANT & BACKER ROD
EACH SIDE TYP.
SEALANT & BACKER ROD
O
7'-4"
O
2'-8"
O
" (TYP.)
CORNER BEAD
IN ALUMINUM FRAME
INSULATED GLASS
LAMINATED AND
†" GYP. BD.
EACH SIDE TYP.
SEALANT & BACKER ROD
@ 16" O.C.
3†" METAL STUD
BATT INSULATION
1"
WINDOWS
SILL DETAIL @
S4
SCALE:1•" = 1'-0"
SHOT-CRETE
SHOT-CRETE
SHOT-CRETE
WALL BEYOND
SHOT-CRETE
PRECAST SILL
SKIMCOAT
STUCCO
SKIMCOAT
STUCCO
SKIMCOAT
STUCCO
SKIMCOAT
STUCCO
†" GYP. BD.
STUD @ 16" O.C.
1•" METAL
†" GYP. BD.
CMU WALL
EXISTING 8"
TYP.
SEALANT EACH SIDE
8ƒ"
2•" 2•"
NEW H.M.FRAME
EXISTING OR
5'-0" A.F.F.
H.M.FRAME
STUD @ 16" O.C.
3†" METAL
†" GYP. BD.
STUD @ 16" O.C.
1•" METAL
†" GYP. BD.
CMU WALL
EXISTING 8"
8ƒ"
2•" 2•"
GROUT SOLID
H.M.FRAME-
STUD @ 16" O.C.
1•" METAL
†" GYP. BD.
STUD @ 16" O.C.
1•" METAL
†" GYP. BD.
CMU WALL
EXISTING 8"
TYP.
SEALANT EACH SIDE
H.M.FRAME
O
E X I
S T I
N G
8ƒ"
VIEW WINDOW
SILL DETAIL @
S5
SCALE:1•" = 1'-0"
2'-8"
4"3"
CRETE
3" SHOT-
4"6†"
5‡"
5‡"
6…" @ W1
@ W2
CHANNEL AT W1)
(WITH RESILIENT
@ 16" O.C.
3†" MTL. STUDS
6…" @ W1
@ W2
CHANNEL AT W1)
(WITH RESILIENT
@ 16" O.C.
3†" MTL. STUDS
4"6‚"
FOR INSTALLATION OF WINDOWS
TO MATCH EXISTING CONDITIONS
PATCH AND REPAIR AS NECESSARY
EXISTING STUD WALL-
FOR INSTALLATION OF WINDOWS
TO MATCH EXISTING CONDITIONS
PATCH AND REPAIR AS NECESSARY
EXISTING STUD WALL-
VIEW WINDOW
HEAD DETAIL @
H5
SCALE:1•" = 1'-0"
VIEW WINDOW
JAMB DETAIL @
J5
SCALE:1•" = 1'-0"
†" GYP. BD.
STUD @ 16" O.C.
1•" METAL
†" GYP. BD.
‡" HAT CHANNEL
CMU WALL
EXISTING 8"
TYP.
SEALANT EACH SIDE
8ƒ"
2•" 1•"
†" GYP. BD.
STUD @ 16" O.C.
1•" METAL
†" GYP. BD.
‡" HAT CHANNEL
CMU WALL
EXISTING 8"
2•" 1•"
H E
D
D O
D T
H
SECURE DOORS
JAMB DETAIL @
J6
SCALE:1•" = 1'-0"
TYP.
SEALANT EACH SIDE
SECURE DOORS
HEAD DETAIL @
H6
SCALE:1•" = 1'-0"
8~0" A.F.F.
7'-2" OR
GLASS
ONE-WAY VIEW
GLASS
ONE-WAY VIEW
GLASS
ONE-WAY VIEW
SECURE DOORS
SILL DETAIL @
S6
SCALE:1•" = 1'-0"
WALL BEYOND
SECURE DOOR FRAMES)
(MATCH EXISTING
GROUT SOLID
METAL FRAME-
SECURE DOOR FRAMES)
(MATCH EXISTING
METAL FRAME-
SECURE DOOR FRAMES)
(MATCH EXISTING
GROUT SOLID
METAL FRAME-
(MATCH EXISTING PROFILE)
THRESHOLD
CERAMIC TILE
THRESHOLD
SYNTHETIC MARBLEAS SCHEDULED
DOOR & FRAME
AS SCHEDULED
DOOR & FRAME
CARPETVCT OR CARPET
TILE/FINISH AS SCHEDULED
SILL DETAIL @ CERAMIC
S1
SCALE:1•" = 1'-0"
VCT
CARPET & VCT
SILL DETAIL @
S2
SCALE:1•" = 1'-0"
STRIP
REDUCING
FOR MORE INFORMATION
METHOD) - SEE STRUCTURAL
MANUFACTURER'S APPROVED
METAL ANGLE (PER
ATTACH FRAME INTO
TO MATCH WALL
SMOOTH AND PAINT
RUB EXISTING CMU
SEALANT
FOR MORE INFORMATION
METHOD) - SEE STRUCTURAL
MANUFACTURER'S APPROVED
METAL ANGLE (PER
ATTACH FRAME INTO
INFORMATION
FOR MORE
STRUCTURAL
ANGLE - SEE
4"1'-1‚"
SEALANT
SIDE (TYP.)
SEALANT EACH
VENEER
SPLITFACE
EXISTNG 8" CMU
4"6‚"7"
(BELOW)
PRECAST SILL
RUNOFF
FOOT FOR WATER
SLOPE „" PER
280 CFM
TYPE A DIFFUSER-SEE SCHEDULE
SYMBOLS DESCRIPTION
FLEXIBLE DUCT CONNECTION
LOW PRESSURE FLEXIBLE DUCT
DUCT RISE IN DIRECTION OF AIR FLOW
DUCT DROP IN DIRECTION OF AIR FLOW
RECTANGULAR MAIN WITH ROUND BRANCH
90° MITERED ELBOW WITH TURNING VANES
CONCENTRIC DUCT TRANSITION
10" DIAMETER ZONE DAMPER
HUMIDISTAT
WALL SWITCH
MOTOR OPERATED DAMPER
ROUND TO SQUARE TRANSITION
ECCENTRIC DUCT TRANSITION
NEW EQUIPMENT, DUCT, ETC.
FLAT OVAL
ROUND
PRESSURE SWITCH
DUCT RISE
DUCT DROP
MANUAL DAMPER
MEDIUM PRESSURE FLEX DUCT
LINED DUCTWORK
HVAC Legend - Ductwork
A-10-280
SMOKE DAMPER
DUCT SPLIT (PROVIDE SPLITTER DAMPER)
BRANCH (PROVIDE WITH 45° ENTRY)
RECTANGULAR MAIN WITH RECTANGULAR
(SUPPLY, OUTSIDE AIR)
POSITIVE PRESSURE DUCT
(RETURN,EXHAUST)
NEGATIVE PRESSURE DUCT
TO REMAIN AS IS
EXISTING EQUIPMENT, DUCT, ETC.
TO BE REMOVED
EXISTING EQUIPMENT, DUCT, ETC.
MOD
OA
OBD
RA
RCF
MOTOR OPERATED DAMPER
OUTSIDE AIR
OPPOSED BLADE DAMPER
RETURN AIR
RECIRCULATING FAN
PSI
PD PRESSURE DROP
MBH 1000 BTUH
SA SUPPLY AIR
RPM REVOLUTIONS PER MINUTE
SP STATIC PRESSURE
KW KILOWATTS
TD
REF
ATD
ABOVE FINISHED FLOOR
TRANSFER DUCT
ROOF EXHAUST FAN
AIR TEMPERATURE DROP
AIR HANDLING UNIT
SEER
ITD
LAT LEAVING AIR TEMPERATURE
AHU
LWT LEAVING WATER TEMPERATURE
NIC NOT IN CONTRACT
RELATIVE HUMIDITY RH
SD SMOKE DAMPER OR STORM DRAIN
AFF
F
BTUH
CHWS
EWT
FT
ESP
CO
COP
CWP
CWR
CWS
D
DB
DN
EAT
FD
FSD
GPM GALLONS PER MINUTE
GPH GALLONS PER HOUR
EER ENERGY EFFICIENCY RATIO
COEFFICIENT OF PERFORMANCE
HORSEPOWER
FAHRENHEIT
CHILLED WATER SUPPLY
FEET
CONDENSER WATER PUMP
CLEANOUT
DRAIN
DRY BULB
DOWN
FIRE/SMOKE DAMPER
FIRE DAMPER OR FLOOR DRAIN
CUBIC FEET PER MINUTE
CHILLED WATER
CHILLED WATER PUMP
CHILLED WATER RETURN
CFM
CHW
CHWP
CHWR
CNTE CONNECT NEW TO EXISTING
CW CONDENSER WATER
HHWP
HEATING HOT WATER SUPPLY
HHWR
HHWS
HHW
HP
BRITISH THERMAL UNIT PER HR
CONDENSER WATER SUPPLY
ENTERING AIR TEMPERATURE
EXTERNAL STATIC PRESSURE
ATR AIR TEMPERATURE RISE
WTR WATER TEMPERATURE RISE
WTD WATER TEMPERATURE DROP
TYP
UNO
VAV VARIABLE AIR VOLUME VALVE
UNLESS NOTED OTHERWISE
TYPICAL
W WATTS
TG TRANSFER GRILLE
ABBREVIATION/DEFINITION
POUNDS PER SQ.IN. WG (GAUGE)
HEATING HOT WATER PUMP
HEATING HOT WATER
APD AIR PRESSURE DROP
AVG AVERAGE
BHP BRAKE HORSEPOWER
CV VALVE COEFFICIENT
FPM FEET PER MINUTE
FPS FEET PER SECOND
KWH KILOWATT HOUR
MOV MOTOR OPERATED VALVE
PRV PRESSURE REDUCING VALVE
PSIA
WPD WATER PRESSURE DROP
BFF BELOW FINISHED FLOOR
FCO FLOOR CLEAN OUT
ENTERING WATER TEMPERATURE
WCO WALL CLEAN OUT
ROUGH-IN AND FINAL CONNECT RI&FC
INVERT ELEVATION
T&P TEMPERATURE AND PRESSURE
NTS NOT TO SCALE
WC WATER COLUMN
POUNDS PER SQ.IN.WG (ABSOLUTE)
HEATING HOT WATER RETURN
INV.
Mechanical
Abbreviations
DUCT AIR EXTRACTOR
TEMPERATURE SENSOR
FOR RATING)
FIRE DAMPER (SEE ARCH.
(SEE ARCH. FOR RATING)
FIRE & SMOKE DAMPER
R
D
OR
10"
P
S
OR
OR
OR XXXXXX
AIR FLOW
T
H
SYMBOLS DESCRIPTION SYMBOLS DESCRIPTION
BUTTERFLY VALVE
THRUST BLOCK
PIPE ANCHOR
HVAC Legend - Piping
DRAIN LINE
FLOW CONTROL VALVE
SUPPY & RETURN
CONDENSER WATER
CONCENTRIC REDUCER
ECCENTRIC REDUCER
STEAM TRAP
FLOW SWITCH
BLIND FLANGE
UNION
MANUAL AIR VENT
VACUUM BREAKER
GAUGE COCK
RELIEF VALVE
NON-SLAM CHECK VALVE
BALANCING VALVE
BALL VALVE
GLOBE VALVE
TEMPERATURE SENSOR
PRESSURE SENSOR
THERMOMETER
FLOW METER
SEE SPECIFICATIONS
SHUTOFF VALVE
P
F
T
P
F
CW
CHW
HHW
CHWS
CHWR
HHWS
HHWR
CWS
CWR
PCR
GCR
HPS
MPS
LPS
X
D
R
CONNECT NEW TO EXISTING
CONDENSER WATER RETURN
AUTOMATIC AIR VENT
SUPPLY & RETURN
HEATING HOT WATER
RETURN
GRAVITY CONDENSATE
RETURN
PUMPED CONDENSATE
EXISTING TO REMAIN
REMOVED
EXISTING TO BE
OR X X X X X X X X X XX
ON THIS DRAWING
REFER TO HVAC NOTE
ON THIS DRAWING
REFER TO HVAC NOTE
INITIAL TEMP. DIFFERENCE
SEASONAL ENERGY EFF. RATIO
10" NECK (ROUND OR SQUARE)
TO EXISTING
CONNECT NEW
(HOT GAS & LIQUID)
REFRIGERANT LINES
PORT (PETE'S PLUG)
PRESSURE & TEMP.
GAUGE COCK
PRESSURE GAUGE W/
CONTROL VALVE
OPERATED
2-WAY MOTOR
CONTROL VALVE
OPERATED
3-WAY MOTOR
DRAIN VALVE
STRAINER W/
VALVE
PRESSURE REDUCING
PRESSURE SWITCH
DIFFERENTIAL
SUPPLY& RETURN
CHILLED WATER
SUPPLY
CHILLED WATER
RETURN
CHILLED WATER
SUPPLY
CONDENSER WATER
RETURN
CONDENSER WATER
STEAM SUPPLY
MEDIUM PRESSURE
STEAM SUPPLY
HIGH PRESSURE
CONNECTION
FLEXIBLE PIPE
JOINT
PIPE EXPANSION
STEAM SUPPLY
LOW PRESSURE
WATER RETURN
HEATING HOT
WATER SUPPLY
HEATING HOT
MECHANICAL GENERAL NOTES
HVAC
DEMOLITION GENERAL NOTES
OF TEMPORARY SERVICES.
EQUIPMENT OR INSTALLATION AND CONNECTION
ALL TESTING, SERVICE FEES, RENTAL OF TEMPORARY
BUILDING SERVICES DURING DEMOLITION INCLUDING
7. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING
FOR RELOCATION.
AND MAKE OPERATIONAL EQUIPMENT INDICATED
6. REMOVE, STORE, CLEAN, REINSTALL, RECONNECT,
AS INDICATED.
OWNER OR REMOVE FROM THE PROJECT SITE
5. REMOVE INDICATED EQUIPMENT AND DELIVER TO THE
PATCH SURFACE TO MATCH EXISTING FINISH.
THE FACE OF ADJACENT CONSTRUCTION. CAP AND
DUCTWORK ABANDONED IN PLACE, 2 INCHES BEYOND
4. CUT AND REMOVE BURIED OR CONCEALED PIPE AND
AND DUCTWORK IN ITS ENTIRETY.
3. REMOVE INDICATED EXPOSED OR ACCESSIBLE PIPE
NEW PRODUCTS OF EQUAL CAPACITY AND QUALITY.
REMOVE DAMAGED PORTIONS AND INSTALL
EQUIPMENT TO REMAIN IS DAMAGED OR DISTURBED,
2. WHERE PIPE, DUCTWORK, INSULATION, OR
WORK INDICATED OR SPECIFIED.
1. DISCONNECT, DEMOLISH, AND REMOVE
M0.1
M E
C H
A N
IC
G E
N
B R
E V
IA
T
IO
N
CONTAMINANTS ARE TO BE INTRODUCED INTO THE SPACE.
IF UNUSUAL CONTAMINANTS OR UNUSUALLY STRONG SOURCES OF SPECIFIC
BE RE-EVALUATED, IF AT A LATER TIME, SPACE USE CHANGES OCCUR OR
ACCEPTABLE INDOOR AIR QUALITY PER ASHRAE 62-1989. THIS DESIGN SHOULD
20.THE VENTILATION RATE PROCEDURE HAS BEEN USED TO ASSURE
THE OVERALL MECHANICAL PRICE.
COORDINATE WITH HIS SUBCONTRACTORS TO ENSURE THAT THIS PRICE IS INCLUDED IN
INSTALL ALL ELECTRICAL POWER TO THE SYSTEMS. IT IS HIS RESPONSIBILITY TO
BY THE MECHANICAL CONTRACTOR. THE LICENSED ELECTRICAL CONTRACTOR SHALL
SWITCHES,TIME CLOCKS AND ALL OTHER CONTROL COMPONENTS IS TO BE PROVIDED
EQUIPMENT POWER AND CONTROL WIRING TO DAMPER MOTORS, VALVE MOTORS,
ELECTRICAL CONTRACTOR BEFORE SUBMITTING SHOP DRAWINGS OR ORDERING
19. COORDINATE VOLTAGE OF ALL MECHANICAL EQUIPMENT WITH
THE FIRE ALARM SYSTEM SHALL BE UL U.L. CERTIFIED
ELECTRICAL CONTRACTOR AND INSTALLED BY NICET LEVEL TWO, MINIMUM, PERSONNEL.
18. DUCT SMOKE DETECTORS SHALL BE FURNISHED AND WIRED BY
SERVICE, ETC.
BECAUSE OF UNIT SIZE, ROOF OPENING SIZE, WEIGHT, LOCATION, ELECTRICAL
RESPONSIBLE FOR COORDINATING WITH ALL DISCIPLINES ANY CHANGES NEEDED
THAT SPECIFIED IN PLANS OR SPECIFICATION, THE CONTRACTOR SHALL BE
17. IF EQUIPMENT TO BE SUPPLIED BY CONTRACTOR IS DIFFERENT THAN
AND REGISTERS (THIS IS IN ADDITION TO OBD AT DIFFUSER).
16. PROVIDE A MANUAL DAMPER IN ALL RUN OUTS TO DIFFUSERS. GRILLES,
RECTANGULAR DUCTWORK.
EXTRACTOR IN ALL ROUND DUCT TAKE-OFFS FROM
15. USE SPIN-IN AND TWIST LOCK FITTINGS WITH QUADRANT AND
TO CROSS.
14. RISE DUCTWORK UP BETWEEN JOISTS WHEN NECESSARY FOR TWO DUCTS
CONFIGURATION,DIMENSIONS, ETC.
13. REFER TO ARCHITECTURAL DRAWINGS FOR ACTUAL BUILDING
OTHERWISE.
12. ALL LOUVER HEIGHTS GIVEN ARE TO TOP OF LOUVER UNLESS NOTED
11. MOUNT ALL THERMOSTATS 5'-0" ABOVE FINISHED FLOOR.
OTHERWISE ON DRAWINGS.
DIFFUSERS TO HAVE 4-WAY AIR FLOW PATTERNS UNLESS INDICATED
10. ALL SLOT DIFFUSERS TO HAVE 2-WAY AIR FLOW PATTERNS & ALL 2X2
IN HORIZONTAL RUNS.
9. CONDENSATE LINES SHALL BE TRAPPED AND SLOPED„" PER FOOT
CONTRACTING OFFICER.
8. VERIFY ALL THERMOSTAT AND FAN SWITCH LOCATIONS WITH THE
7. DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR DIMENSIONS.
OF CAPPED DUCTS ARE NOT ACCEPTABLE.
TAPERED SQUARE TO ROUND TRANSITIONS. SPIN-IN FITTINGS AT THE END
6. ALL DUCT TRANSITIONS FROM SQUARE TO ROUND SHALL BE SMOOTH AND
MAXIMUM LENGTH= 8 FEET.
SAGS AND KINKS AND SHALL BE THE SAME SIZE AS THE DIFFUSER INLET.
5. FLEXIBLE DUCT RUN OUTS TO CEILING DIFFUSERS SHALL BE FREE OF
TOP OF DUCTWORK LEVEL AND AS HIGH AS POSSIBLE.
4. TRANSITION RECTANGULAR DUCTWORK ON BOTTOM AND SIDES. MAINTAIN
(MAX.) ALL AROUND EXTERIOR PERIMETER OF DUCT.
X 1 / 8 GALVANIZED STEEL ANGLES BOLTED OR RIVETED 6" ON CENTER
3. ALL OPEN ENDED DUCTS SHALL BE REINFORCED WITH 1-1/2" X 1-1/2"
ENGINEER SHOWING HIS PROPOSED SOLUTION.
THE MECHANICAL CONTRACTOR SHALL SUBMIT A DRAWING TO THE
UNLESS NOTED ON THE STRUCTURAL PLANS. WHERE CONFLICTS ARISE
EQUIPMENT CURBS. AVOID PENETRATING ANY STRUCTURAL MEMBERS
ALL ROOF, WALL AND FLOOR PENETRATIONS AND ROOF MOUNTED
2. COORDINATE WITH STRUCTURAL CONTRACTOR THE EXACT LOCATION OF
COORDINATE ITS LOCATION WITH ALL DISCIPLINES.
PARTICULAR ITEM IS NOT SHOWN ON THE REFLECTED CEILING PLANS,
LOCATION OF ALL CEILING MOUNTED AIR DISTRIBUTION DEVICES. IF A
1. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT
D G
N S
P E
C
S
Y S
T
IM
E
U S
E R
N A
M E
12345
D
C
B
A
5 4 3 2
A
B
C
D
$$DGNSPEC$$
$$SYSTIME$$
$$USERNAME$$
S Y
M B
O L
D E
S C
R
IP
T
IO
N D
A T
E B
Y P
L
A L
S
IG
N
D A
T E
NUMBER:
REFERENCE
E
P L
A L
S
IG
N
D A
T E
P L
A L
E
W
H N
C
E C
K
D E
S
IG
N
D A
T E
F
US ARMY CORPS
OF ENGINEERS
SAVANNAH DISTRICT
.7
.0
C O
L U
M B
IA
S O
U
R O
L
IN
A
R E
E T
S O
U
R O
L
IN
A
IN
C
S T
E V
E
K
IN
S
IL
D
N O
V A
T
IO
T O
B
L
IC
IT
A T
S O
L
IC
IT
A T
W
H N
R
N T
R A
M O
T S
U
N O
R
R O
L
System No. C-AJ-5098
SECTION A-A
F RATING = 2-HR.
T RATING = 1-HR.
C
J
FIRESTOP SYSTEMS
A
5A
Reproduced by HILTI, Inc. Courtesy of
Underwriters Laboratories, Inc.
Revised 18, AUG. 1999
5B
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .