AMDT0005_88658_Technical_Summary_Changes_Final_1.20.21.pdf
PDF 2 MB Posted
- Attached to
- PN 88658 SOF Operations Facility Federal contract opportunity
- Solicitation number
- W912PM20R0009
About this file
This is a solicitation for construction services. The selected contractor will construct a SOF Operations Facility including administrative areas, mission planning spaces, vehicle bays, climate controlled storage, petroleum storage, arms vaults, individual unit storage, workshops, latrines with lockers, and laundry. The facility will also include a Secure Compartmentalized Information Facility with administrative area, classroom, operations center, and Special Access Programs spaces. The project scope includes fire alarm, suppression, security, communications, and audiovisual systems. Sustainability, accessibility, and cybersecurity measures will be incorporated. Supporting site work includes utilities, lighting, storm drainage, landscaping, and fencing. The Army Corps of Engineers Engineering District Wilmington is the issuing agency. Responses were due under Solicitation Number W912PM20R0009.
View the file
Other files for this federal contract opportunity
Show all 50
PN 88658 SOF Operations Facility has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Solicitation #W912-PM-20-R-0009 88658 - SOF Operations Facility - Fort Bragg, North Carolina Amendment No. 0005 Date: 20 JAN 2021
SUMMARY OF CHANGES
1. CHANGES TO SPECIFICATIONS. Attached hereto are [new, revised and deleted] sections to the specifications. Revised sections replace like numbered sections. Revised pages replace likenumbered pages. Revision mark “****Amendment 0005****” is shown on each revised page.
A. REVISED SECTIONS. The following revised sections replace like numbered sections.
Changes to text are indicated by underline and/or strike-through.
PROJECT TABLE OF CONTENTS (Revised to delete reference to Section 10 26 00) 00 01 15 LIST OF DRAWINGS w/Revised Attachment.
01 14 00 WORK RESTRICTIONS
01 91 00.00 37 COMMISSIONING w/New Attachment.
07 27 10.00 10 BUILDING AIR BARRIER SYSTEM
08 44 00 CURTAIN WALL, GLAZED ASSEMBLIES AND SUN CONTROL
08 81 00 GLAZING
B. NEW SECTIONS. The following sections are added to the specifications: None.
C. DELETED SECTIONS: The following sections are deleted from the specifications:
10 26 00 WALL AND DOOR PROTECTION.
2. CHANGES TO DRAWINGS. Attached hereto are [new and revised] drawing sheets. Revised sheets replace like-numbered sheets. The revision tracker in the Title Block of each sheet is populated to reflect the current Amendment Number and issue date.
A. REVISED DRAWINGS (ISSUED). The following revised drawings replace like numbered drawings and are issued herewith:
Sheet ID Volume Mark Revision Date A-601 Volume 1 1 01/19/2021 A-603 Volume 1 1 01/19/2021 A-610 Volume 1 1 01/19/2021 A-625 Volume 1 1 01/19/2021 G-003 Volume 1 1 01/19/2021 G-003 Volume 2 1 01/19/2021 IN101A Volume 1 2 01/19/2021 IN101B Volume 1 1 01/19/2021 IN102A Volume 1 1 01/19/2021 IN102B Volume 1 1 01/19/2021 M-503 Volume 2 1 01/19/2021 TY-001 Volume 2 1 01/19/2021
Solicitation #W912-PM-20-R-0009 88658 - SOF Operations Facility - Fort Bragg, North Carolina Amendment No. 0005 Date: 20 JAN 2021
SUMMARY OF CHANGES Cont.
B. NEW DRAWINGS (ISSUED). The following new drawings are added to the drawing set and are issued herewith:
Sheet ID Volume Mark Date TA-112B Volume 2 1 01/19/2021
…end of summary…
A. REFER TO SHEET G-004 FOR ABBREVIATIONS.
B. REFER TO SHEET A-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS.
C. REFER TO LIFE SAFETY PLANS FOR REQUIRED FIRE RATED PARTITION LOCATION.
D. SMOKE AND/OR FIRE RATED PARTITIONS SHALL BE CONSTRUCTED PER THE REQUIREMENTS OF THE U.L.
TEST ASSEMBLY IDENTIFIED. PARTITIONS SHALL EXTEND FROM STRUCTURAL SLAB TO STRUCTURAL SLAB. PROVIDE CONTINUOUS FIRE STOPPING/ SEALANT BOTH SIDES, TOP AND BOTTOM, AND AT ALL
PENETRATIONS.
E. ALL FIRE BARRIERS AND FIRE PARTITIONS SHALL BE DESIGNATED ABOVE THE CEILING AND ON ALL CEILING ACCESS DOORS WHICH PROVIDE ACCESS TO SUCH FIRE RATED ASSEMBLIES BY SIGNAGE HAVING LETTERS NO SMALLER THAN 1 INCH IN HEIGHT. SUCH SIGNAGE SHALL INDICATE THE FIRE RESISTANCE OF THE ASSEMBLY AND THE TYPE OF ASSEMBLY, AND BE PROVIDED AT HORIZONTAL
INTERVALS OF NO MORE THAN EIGHT FEET.
F. ALL FULL HEIGHT PARTITIONS SHALL PROVIDE FOR VERTICAL MOVEMENT AT THE STRUCTURAL JOINT AT THE SLAB ABOVE. ALL METAL STUD PARTITIONS SHALL BE CONSTRUCTED WITH A SLIP JOINT BETWEEN STUDS AND THE TOP RUNNER TRACK OR USE A SLOTTED DEFLECTION TRACK THAT ALLOWS FOR A
MAXIMUM STRUCTURAL DEFLECTION OF 3/4". SEAL ALL JOINTS TOP AND BOTTOM.
G. PROVIDE METAL OR SOLID FRT WD BLOCKING AT PARTITIONS AS REQUIRED TO ACCOMMODATE INSTALLATION OF CASEWORK, LOCKERS, GRAB BARS, HANDRAILS, AV EQUIPMENT, SIGNAGE AND OTHER
WALL MOUNTED SCHEDULED EQUIPMENT AND ACCESSORIES.
H. GYPSUM BOARD PARTITIONS SPANNING ABOVE DOOR/WINDOW OPENINGS 6'-0" WIDE OR MORE SHALL BE
DIAGONALLY BRACED AT 6'-0" OC.
I. ALL METAL STUD SPACING SHALL BE 16" OC UNO.
J. PROVIDE GWB CONTROL JOINTS AND CONSTRUCT IN ACCORDANCE WITH GYPSUM ASSOCIATION GA
216-2016 AND AS INDICATED ON THE DRAWINGS. AT CONTROL JOINTS IN RATED PARTITIONS OR AT
CONTROL JOINTS IN STC 45 WALLS AND GREATER, REFER TO DETAIL 1 ON SHT A-601.
K. PROVIDE MOISTURE RESISTANT GWB AT ALL PARTITIONS AND SHAFT WALLS WITH WATER CLOSETS, URINALS, LAVATORIES, UTILITY SINKS, MOP BASINS, ELECTRIC WATER COOLERS AND WHERE
SCHEDULED TO RECEIVE EPOXY PAINT.
L. PROVIDE ABUSE RESISTANT GWB TO 8'-0" AFF AT ALL CORRIDORS, LOBBY, VESTIBULE, VEHICLE BAY 100D, STAGING AREA 100E, STAGING 200B AND STAGING 200F.
M. ALL GYPSUM BOARD SHALL BE 5/8" TYPE "X" UNO.
N. ALL INTERIOR PARTITIONS SHALL BE TYPE P21 UNO.
O. ALL VERTICAL MEP SHAFTS/CHASES SHALL BE TYPE P52, 2-HR FIRE RATED SHAFTWALL UNO.
P. THE CONTRACTOR SHALL PERFORM FIELD TESTING TO CERTIFY THAT THE ACOUSTICAL WALL
CONSTRUCTION INDICATED HAS BEEN MET. THE CONTRACTOR MAY CHOOSE TO USE EITHER NOISE ISOLATION CRITERIA (NIC) OR FIELD SOUND TRANSMISSION CLASS (FSTC) TESTING TO DETERMINE FIELD RATINGS OF CONSTRUCTED SOUND RATED PARTITIONS. CONTRACTOR TESTING MUST COMPLY WITH
ICD/ICS 705 REQUIREMENTS. SUBMIT TESTING EQUIPMENT AND PROCESSES TO BE USED TO
CONTRACTING OFFICER FOR APPROVAL. WALLS TESTED MUST HAVE A SOUND RATING OF NIC OR FSTC 45 AT STC 50 PARTITIONS, AND NIC OR FSTC 40 AT STC 45 PARTITIONS. THE CONTRACTOR WILL BE RESPONSIBLE FOR PERFORMING REMEDIAL WORK TO MEET THE REQUIRED FIELD SOUND RATINGS.
Q. GOVERNMENT WILL PERFORM INDEPENDENT SOUND TESTING IN ADDITION TO CONTRACTOR'S SOUND
TESTING. CONTRACTOR WILL BE RESPONSIBLE FOR PERFORMING REMEDIAL WORK TO MEET THE
REQUIRED FIELD SOUND RATINGS RESULTING FROM GOVERNMENT TESTING.
R. LOCATE DEVICES IN ACOUSTICAL PARTITIONS IN A MANNER THAT MAINTAINS THE ACOUSTICAL
PROPERTIES OF THE PARTITION. REFER TO DETAIL 2 ON A-601.
S. LABEL FIRE RATED AND SMOKE RATED PARTITIONS WITH STENCILING OR SIGNS. LOCATE
IDENTIFICATION BELOW RAISED ACCESS FLOOR AND ABOVE ACCESSIBLE CEILINGS. SPACE
IDENTIFICATION AT NO MORE THAN 10 FEET ON CENTER MEASURED HORIZONTALLY ALONG THE
PARTITION. INCORPORATE LETTERING NOT LESS THAN 1 INCH IN HEIGHT. LABEL WITH RESISTANCE
RATING (E.G. "1 HOUR FIRE RATED PARTITION, PROTECT ALL OPENINGS").
GENERAL NOTES THIS SHEET:
Top
Plan
Base
Top
Plan
Base
(1) LAYER 5/8"
GYPSUM BOARD
ONE SIDE
1 1/2" METAL STUDS @
16" O.C. @ P01. 7/8"
METAL HAT CHANNEL
FURRING @16" O.C. @
P01A (1) LAYER 5/8" GYPSUM
BOARD EACH SIDE
6" METAL STUDS @ 16"
O.C.
UNDERSIDE OF
STRUCTURE
PROVIDE SLOTTED
DEFLECTION
TRACK ASSEMBLY
RUNNER TRACK
CEILING AS SCHED -
SEE FINISH SCHEDULE
(1) LAYER 5/8"
GYPSUM BOARD ONE
SIDE
2 1/2" METAL STUDS @
16" O.C.
RUNNER TRACK
CEILING AS SCHED -
SEE FINISH SCHEDULE
3" SOUND
ATTENUATION
INSULATION
P01 1 1/2" METAL STUDS @ 16" O.C. P21 6" METAL STUDS @ 16" O.C., SMOKE TIGHT W/
ACOUSTICAL BATT INSULATION
P21A 6" METAL STUDS @ 16" O.C., SMOKE TIGHT W/ NO
ACOUSTICAL BATT INSULATION
FLOOR AND BASE AS
SCHED - SEE FINISH
SCHEDULE
FLOOR AND BASE AS
SCHED - SEE FINISH
SCHEDULE
FLOOR AND BASE AS
SCHED - SEE FINISH
SCHEDULE
(1) LAYER 5/8"
GYPSUM BOARD ONE
SIDE
3 5/8" 20 GAUGE
METAL STUDS @ 16"
O.C.
RUNNER TRACK
CEILING AS SCHED - SEE
FINISH SCHEDULE
P12A 2 1/2" METAL STUDS @ 16" O.C.
FLOOR AND BASE AS
SCHED - SEE FINISH
SCHEDULE
CEILING AS SCHED - SEE
FINISH SCHEDULE
P02 2 1/2" METAL STUDS @ 16" O.C.
(1) LAYER 5/8" GYPSUM
BOARD EACH SIDE
3 5/8" METAL STUDS @
16" O.C.
UNDERSIDE OF
STRUCTURE
PROVIDE SLOTTED
DEFLECTION
TRACK ASSEMBLY
RUNNER TRACK
3" SOUND
ATTENUATION
INSULATION
P22 3 5/8" METAL STUDS @ 16" O.C. W/ ACOUSTICAL BATT
INSULATION
P22A 3 5/8" METAL STUDS @ 16" O.C. W/ NO ACOUSTICAL BATT
INSULATION
P22B 6" METAL STUDS @ 16" O.C. W/ ACOUSTICAL
BATT INSULATION
FLOOR AND BASE AS
SCHED - SEE FINISH
SCHEDULE
CEILING AS SCHED - SEE
FINISH SCHEDULE
UNDERSIDE OF
STRUCTURE
PROVIDE SLOTTED
DEFLECTION
TRACK ASSEMBLY
P52 STC 50; 2 1/2" C-H STUDS
"J" RUNNER TRACK
FLOOR AND BASE AS
SCHED - SEE FINISH
SCHEDULE
FIRESTOP SEALANT,
TOP & BOT.
3" MINERAL WOOL
BATT INSUL
UL DESIGN NO. U415 - SYSTEM B, 2 HOUR SYSTEM
STC 50 - SOUND TEST RAL-OT04-019 W/ MINERAL WOOL
2 1/2" OR 4" VENTED 20
GAUGE METAL CH STUDS
@ 24" O.C.
(2) LAYERS 5/8" TYPE "X"
OR (1) LAYER 1/2"
FIRECODE TYPE "C"
GYPSUM BOARD
(1) LAYER 1" X 24" TYPE "X"
GYPSUM LINER PANEL
UNDERSIDE OF
STRUCTURE
FIRESAFE / SEAL TIGHT
TO DECK, SEE NOTES
PROVIDE SLOTTED DEFLECTION
TRACK ASSEMBLY
CEILING AS SCHED - SEE
FINISH SCHEDULE
P61 8" CMU W/ 7/8" FURRING AND 5/8" GWB ONE SIDE ONLY
FLOOR AND BASE AS
SCHED - SEE FINISH
SCHEDULE
7/8" METAL HAT CHANNEL
FURRING @16" O.C. ONE
SIDE ONLY
(1) LAYER 5/8" GWB, ONE
SIDE ONLY
8" NOMINAL CMU
UNDERSIDE OF
STRUCTURE
CEILING AS SCHED - SEE
FINISH SCHEDULE
6" 6"
6"
6"
6"
P12B 3 5/8" METAL STUDS @ 16" O.C.
(2) LAYERS 5/8" TYPE
"X" GYPSUM BOARD
EACH SIDE
6" METAL STUDS @
16" O.C.
3" SAFB SOUND
ATTENUATION
FIRE BLANKET
UNDERSIDE OF
STRUCTURE
FIRESAFE / SEAL TIGHT
TO DECK, SEE NOTES
PROVIDE SLOTTED
DEFLECTION
TRACK ASSEMBLY
UL DESIGN NO. U411 OR U419 - 1 HOUR SYSTEM W/
UL SYSTEM NO. HW-D-0060 AT HEAD JOINT
P41 6" METAL STUDS; STC 50
CEILING AS SCHED - SEE
FINISH SCHEDULE
RAISED ACCESS
FLOOR WHERE
OCCURS
FLOOR AND BASE AS
SCHED - SEE FINISH
SCHEDULE
FIRESTOP SEALANT,
TOP & BOT.
P41A 6" METAL STUDS; STC 45
P81 8" CAST-IN-PLACE CONCRETE
FLOOR AND BASE AS
SCHED - SEE FINISH
SCHEDULE
8" CAST-IN-PLACE CONC - SEE
STRL
UNDERSIDE OF
STRUCTURE
CONC CEILING - SEE STRL
(1) LAYER 5/8" GYPSUM BOARD
LAMINATED TO CONC
CONC SLAB
BID OPTION 1
(1) LAYER 5/8" TYPE "X"
GYPSUM BOARD EACH
SIDE
3 5/8" OR 6" METAL
STUDS @ 16" O.C.
3" SAFB SOUND
ATTENUATION
FIRE BLANKET
UNDERSIDE OF
STRUCTURE
FIRESAFE / SEAL TIGHT
TO DECK, SEE NOTES
PROVIDE SLOTTED
DEFLECTION
TRACK ASSEMBLY
RUNNER TRACK
UL DESIGN NO. U419 - 1 HOUR SYSTEM W/
UL SYSTEM NO. HW-D-0060 AT HEAD JOINT
STC 49 - SOUND TEST SA-870717
P23 1 HR FIRE/SMOKE BARRIER UL DESIGN NO. U419
P23A 1 HR FIRE/SMOKE BARRIER UL DESIGN NO. U419 W/ 6"
METAL STUDS @ 16" O.C.
FLOOR AND BASE AS
SCHED - SEE FINISH
SCHEDULE
CEILING AS SCHED - SEE
FINISH SCHEDULE
FIRESTOP SEALANT, TOP
& BOT.
P23B NON-FIRE-RATED P23 UL DESIGN NO. U419
STC-45 (NIC-40) SOUND RATED SA-870717
P41B 6" METAL STUDS; STC 45
P41D 6" METAL STUDS; STC 50; 1 HR
FIRE/SMOKE BARRIER UL
DESIGN NO. U419
P12C 6" METAL STUDS @ 16" O.C.
RUNNER TRACK
P01A 7/8" METAL HAT CHANNEL
@ 16" O.C.
P61A SAME AS P61 BUT NO FURRING OR GWB
P61B SAME AS P61 BUT 1 HR FIRE/SMOKE BARRIER
UL DESIGN NO U910
UL DESIGN NO. U910 - 1 HOUR SYSTEM W/ UL
SYSTEM AT HEAD JOINT
BATT INSUL
PER PTN TYPE
MET. FRAMING
PER PTN TYPE
GWB PER
PTN TYPE
GWB PER
PTN TYPE
1/2" MAX
2 LAYERS 5/8" GWB
GWB CJ
5/8" GAP CONT SNT
BATT INSUL PER PTN TYPE
MET. FRAMING PER PTN TYPE
GWB PER PTN TYPE
ACOUSTIC PUTTY PAD AT
DEVICE BACKBOXES (@ ALL
SIDES), TYP
ACOUSTIC SEALANT
BETWEEN EDGE OF WALL AND
BACKBOX (@ ALL SIDES), TYP
GENERAL NOTE: DETAIL APPLIES TO
BACKBOXES IN ALL PARTITIONS
SCHEDULED TO HAVE STC RATINGS.
DEVICE BACKBOX, TYP
1'-6" MIN
US Army Corps of Engineers ® Wilmington District
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
C
AT
EG
O
R Y
C O
D E:
1 2 3 4 5
A
FO
R
T
BR
AG
G
, N O
R
TH
C
AR
O
LI
N A
SO
F
O
PE
R
AT
IO
N
S
FA
C
IL
IT
Y
FY
0, P
N
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
W
IL
M
IN
G
TO
N , N
O R
TH
C
A R
O
LI
N A
AE
C
O M
S
ER
VI
C
E S, IN
C
S J
EF
FE
R
SO
N S
T
ST
E
R
O A
N O
K E
VA
9/
/2
7 8 9 10
B
C
D
E
F
G
TM
J
W
2P M
R
UNCLASSIFIED//FOR OFFICIAL USE ONLY
UNCLASSIFIED//FOR OFFICIAL USE ONLY
W
2H N
-1 4-
D -0
READY TO ADVERTISE (RTA) SUBMISSION
A-601
PA
R
TI
TI
O N
T
YP
ES
R
BT
JB KB
FY
PN
8A
-6
.d w g
3" = 1'-0"A-601
1 CJ AT ACOUSTIC PTN
1 1/2" = 1'-0"A-601
DEVICE BACKBOX
@ ACOUSTIC PTN
M
AR
K
DE
SC
RI
PT
IO
N
DA
TE
AM
EN
DM
EN
T
1/
/2
A. REFER TO SHEET G-004 FOR ABBREVIATIONS.
B. REFER TO SHEET A-001 FOR GENERAL NOTES, LEGENDS
AND SYMBOLS.
C. REFER TO ARCHITECTURAL ENLARGED PLANS FOR DOOR
TAG LOCATIONS.
D. COORDINATE REQUIRED FIRE RATED DOORS WITH FIRE
RATED PARTITIONS, REFER TO LIFE SAFETY PLAN.
E. REFER TO SHEET A-622, A-623, A-625 AND A-640 FOR
HOLLOW METAL WINDOW AND CURTAINWALL FRAME
TYPES. SEE SPECIFICATION SECTION 08 44 00 FOR
CURTAINWALL REQUIREMENTS.
F. FRAME DEPTH FOR WRAP-AROUND HOLLOW METAL
FRAMES SHALL BE THE WIDTH OF THE PARTITION PLUS
1-1/8" OR AS NOTED. SEE PARTITION TYPES, SHEET A-601.
G. FIELD VERIFY OPENINGS PRIOR TO FABRICATION OF
ALUMINUM ENTRANCE SYSTEMS.
H. VIEW WINDOWS IN RATED DOORS ARE TO BE 100 SQ.
INCHES MAX.
I. SEE SPECIFICATIONS FOR DOOR HARDWARE SETS. REVIEW
ALL HARDWARE SETS AND LOCK FUNCTIONS WITH OWNER
PRIOR TO DEVELOPING FINAL HARDWARE SETS.
J. REFER TO ELECTRICAL AND TELECOM DRAWINGS FOR
POWER AND/OR CARD READER ACCESS REQUIREMENTS.
K. DOORS LOCATED NEAR PERPENDICULAR WALLS ARE TO BE
SET WITH FRAME 4" FROM FACE OF PERPENDICULAR WALL.
L. SEE SPECIFICATION 08 44 00 FOR ASTM CURTAINWALL
SYSTEM REQUIREMENTS.
GENERAL NOTES THIS SHEET:
H
W
H
W W W W
6" 6"
H
H
W
H
W
A B C
E - BID OPTION OVHD COILING
GL AS
SCHED
H
W W
D
GL AS
SCHED
ARMORY
H
W
F
GL AS
SCHED
2' -0
3'
-6
5"
3' -6
2'
-9
2'-8"
2" H
2" W 2"
2" H
2" W W 2"
4" H
2" W 2"
4" H
4" W 4"
F1 F2 F3
F4 - BID OPTION
2" H
2" W W 2"
2' -0
2"
F2A
GLASS AS
SCHED
2" H
2" W 2"
F5
STEEL
CHANNEL
FRAME
2" H
2" W 2"
F1A
GLASS AS
SCHED
2' -0
2"
ARMORY
2" H
2" W 2"
F6
STEEL CHANNEL
FRAME
SEE STRL DWGS
FOR OVHD DOOR
HOOD SUPPORT
SEE DETAIL 17/A-610
FOR TRANSOM DETAIL
GL-1 - LAMINATED STC-50 SOUND RATED GLASS
GL-2 - FIRE RATED GLAZING
GL-3 - TINTED INSULATED GLASS (LAMINATED)
GL-4 - TINTED INSULATING GLASS (LAMINATED) WITH FROSTED FILM
GL-5 - 1/4" THICK CLEAR TEMP GLASS
GL-6 - SPANDREL GLASS
GL-7 - 1/2" THICK CLEAR LAMINATED GLASS WITH FROSTED FILM
GL-8 - 1/2" THICK TINTED LAMINATED GLASS
GLASS SCHEDULE / TYPES
GENERAL NOTE - GLAZING
FOR GLAZING IN EXTERIOR BUILDING ELEMENTS, DOORS,
WINDOWS, CURTAIN WALLS, AND CLERESTORIES, PROVIDE NO
LESS THAN 1/4" (6MM) NOMINAL POLYCARBONATE OR
LAMINATED GLASS. THE 1/4" (6MM) LAMINATED GLASS CONSISTS
OF TWO NOMINAL 1/8" (3MM) GLASS PANES BONDED TOGETHER
WITH A MINIMUM OF A 0.030" (0.75MM) INTERLAYER OF A
MATERIAL DESIGNED FOR BLAST RESISTANCE IAW UFC 4-010-01,
STANDARD 10. REFER TO SPEC SECTION 08 81 00 GLAZING FOR
MORE INFORMATION.
4' 2' 0 4' 8' 1/4"=1'-0"
US Army Corps of Engineers ® Wilmington District
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
C
AT
EG
O
R Y
C O
D E:
1 2 3 4 5
A
GRAPHIC SCALES
FO
R
T
BR
AG
G
, N O
R
TH
C
AR
O
LI
N A
SO
F
O
PE
R
AT
IO
N
S
FA
C
IL
IT
Y
FY
0, P
N
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
W
IL
M
IN
G
TO
N , N
O R
TH
C
A R
O
LI
N A
AE
C
O M
S
ER
VI
C
E S, IN
C
S J
EF
FE
R
SO
N S
T
ST
E
R
O A
N O
K E
VA
9/
/2
7 8 9 10
B
C
D
E
F
G
TM
J
W
2P M
R
UNCLASSIFIED//FOR OFFICIAL USE ONLY
UNCLASSIFIED//FOR OFFICIAL USE ONLY
W
2H N
-1 4-
D -0
READY TO ADVERTISE (RTA) SUBMISSION
A-603
D O
O R
S C
H
ED
U
LE
D
O O
R T
YP
ES
D es ig ne r
Au th or
C he ck er
FY
PN
8A
-6
.d w g
DOOR SCHEDULE
DOOR
NO.
DOOR
TYPE
DOOR INFORMATION FRAME INFORMATION
HW
SET
SECURITY
DOOR
DETAIL COMMENTS:
SIZE DOOR
MATL
DOOR
FINISH
UNDER
CUT
Glass Type
FIRE
RATING
FRAME
TYPE
FRAME
MATL
FRAME
FINISH
DETAILS
WIDTH HEIGHT HEAD JAMB SILL
10 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F1 HM PAINT 3 / A-610 4 / A-610 INT-08
10A A 3' - 0" 7' - 0" HM PAINT - - - F1 HM PAINT 7 / A-610 8 / A-610 EXT-03A
11A B 6' - 0" 7' - 0" HM PAINT - - - F1 HM PAINT 7 / A-610 8 / A-610 EXT-06
11B A 4' - 0" 8' - 0" HM PAINT - - 45 MIN F2 HM PAINT 3 / A-610 4 / A-610 INT-07A
12 A 4' - 0" 7' - 0" HM PAINT - - - F3 HM PAINT 11 / A-610 12 / A-610 INT-13
13 A 4' - 0" 7' - 0" HM PAINT - - - F1 HM PAINT 5 / A-610 6 / A-610 INT-06 STC-45
14 A 3' - 0" 7' - 0" HM PAINT 3/4" - - F1 HM PAINT 3 / A-610 4 / A-610 INT-14
15 A 3' - 0" 7' - 0" HM PAINT 3/4" - - F1 HM PAINT 3 / A-610 4 / A-610 INT-15
15A A 3' - 0" 7' - 0" HM PAINT - - - F1 HM PAINT 3 / A-610 4 / A-610 INT-15
15AA A 3' - 0" 7' - 0" HM PAINT - - 45 MIN F1 HM PAINT 3 / A-610 4 / A-610 INT-16
15B A 3' - 0" 7' - 0" HM PAINT 3/4" - - F1 HM PAINT 3 / A-610 4 / A-610 INT-17
30 A 3' - 0" 7' - 0" HM PAINT - - - F3 HM PAINT 7 / A-610 8 / A-610 EXT-05 POL STOR BLDG 30A OVHD 6' - 6" 8' - 0" STL PREFIN - - - F5 STL PAINT 3 / A-611 4 / A-611 EXT-04 ELECTRIC OPERATION, POL STOR BLDG 100 C 6' - 0" 8' - 0" GLASS PREFIN - GL-7 - F2 ALUM PREFIN 15 / A-610 16 / A-610 INT-01 INTERIOR FULL GLASS 100A C 6' - 0" 8' - 0" GLASS PREFIN - GL-8 - F2 ALUM PREFIN 15 / A-610 16 / A-610 EXT-01 EXTERIOR FULL GLASS 100B D 6' - 0" 7' - 0" HM PAINT - GL-2 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-20
100C A 3' - 0" 7' - 0" HM PAINT - - - F1 HM PAINT 13 / A-610 14 / A-610 EXT-03
100D OVHD 16' - 0" 13' - 0" STL PREFIN - - - F6 STL PAINT 1 / A-611 2 / A-611 EXT-04 ELECTRIC OPERATION, INSULATED 100E OVHD 16' - 0" 13' - 0" STL PREFIN - - - F6 STL PAINT 1 / A-611 2 / A-611 EXT-04 ELECTRIC OPERATION, INSULATED
100F A 3' - 0" 7' - 0" HM PAINT - - - F1 HM PAINT 13 / A-610 14 / A-610 EXT-03
100K D 6' - 0" 7' - 0" HM PAINT - GL-2 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-20
102 B 6' - 0" 7' - 0" HM PAINT - - - F2 HM PAINT 3 / A-610 4 / A-610 INT-04
102A A 4' - 0" 7' - 0" HM PAINT - - - F1A HM PAINT 3 / A-610 4 / A-610 INT-03
103A A 3' - 0" 7' - 0" WD PREFIN STAIN - - - F1 HM PAINT 5 / A-610 6 / A-610 INT-06A STC-50 103B A 3' - 0" 7' - 0" WD PREFIN STAIN - - - F1 HM PAINT 5 / A-610 6 / A-610 INT-06A STC-50 104 A 4' - 0" 7' - 0" HM PAINT - - 45 MIN F1 HM PAINT 3 / A-610 4 / A-610 INT-09 STC-50 105 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-05 106 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-05 107 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-23 108 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-05 109A1 OVHD 10' - 0" 11' - 6" STL PREFIN - - 45 MIN F6 STL PAINT 5 / A-611 6 / A-611 INT-24 ELECTRIC OPERATION, FIRE RATED 109A2 F 4' - 0" 7' - 0" HM PAINT - GL-2 45 MIN F1A HM PAINT 3 / A-610 4 / A-610 INT-29 109B1 OVHD 10' - 0" 11' - 6" STL PREFIN - - 45 MIN F6 STL PAINT 5 / A-611 6 / A-611 INT-24 ELECTRIC OPERATION, FIRE RATED 109B2 F 4' - 0" 7' - 0" HM PAINT - GL-2 45 MIN F1A HM PAINT 3 / A-610 4 / A-610 INT-29 109C1 OVHD 10' - 0" 11' - 6" STL PREFIN - - 45 MIN F6 STL PAINT 5 / A-611 6 / A-611 INT-24 ELECTRIC OPERATION, FIRE RATED 109C2 F 4' - 0" 7' - 0" HM PAINT - GL-2 45 MIN F1A HM PAINT 3 / A-610 4 / A-610 INT-29 109D F 4' - 0" 7' - 0" HM PAINT - GL-2 45 MIN F1A HM PAINT 3 / A-610 4 / A-610 INT-05
110 B 6' - 0" 7' - 0" HM PAINT - - - F2 HM PAINT 3 / A-610 4 / A-610 INT-04
110A A 4' - 0" 7' - 0" HM PAINT - - - F1A HM PAINT 3 / A-610 4 / A-610 INT-03
S1B A 3' - 0" 7' - 0" HM PAINT - - - F3 HM PAINT 7 / A-610 8 / A-610 EXT-03
S3B A 3' - 0" 7' - 0" HM PAINT - - - F3 HM PAINT 9 / A-610 10 / A-610 EXT-03
S3C A 3' - 0" 6' - 6" HM PAINT - - 45 MIN F1 HM PAINT 9 / A-610 10 / A-610 EXT-07
20 A 4' - 0" 7' - 0" HM PAINT - - 45 MIN F1 HM PAINT 3 / A-610 4 / A-610 INT-18
20A A 3' - 0" 7' - 0" HM PAINT - - - F1 HM PAINT 3 / A-610 4 / A-610 INT-11
21 A 3' - 0" 7' - 0" HM PAINT 3/4" - - F1 HM PAINT 3 / A-610 4 / A-610 INT-14
22 A 3' - 0" 7' - 0" HM PAINT - - - F1 HM PAINT 3 / A-610 4 / A-610 INT-15
23 A 3' - 0" 7' - 0" HM PAINT 3/4" - - F1 HM PAINT 3 / A-610 4 / A-610 INT-17
24 A 4' - 0" 7' - 0" HM PAINT - - 45 MIN F1 HM PAINT 5 / A-610 6 / A-610 INT-06 STC-45
25 A 3' - 0" 7' - 0" HM PAINT - - 45 MIN F1 HM PAINT 3 / A-610 4 / A-610 INT-19
201 A 4' - 0" 7' - 0" WD PREFIN STAIN - - 45 MIN F1 HM PAINT 5 / A-610 6 / A-610 INT-06 STC-50 201A A 3' - 6" 7' - 0" WD PREFIN STAIN - - - F1 HM PAINT 5 / A-610 6 / A-610 INT-12 STC-45 201B A 3' - 6" 7' - 0" WD PREFIN STAIN - - - F1 HM PAINT 5 / A-610 6 / A-610 INT-09A STC-45 201BA A 3' - 6" 7' - 0" WD PREFIN STAIN - - - F1 HM PAINT 5 / A-610 6 / A-610 INT-26 STC-45 201C A 3' - 6" 7' - 0" WD PREFIN STAIN - - - F1 HM PAINT 5 / A-610 6 / A-610 INT-09 STC-50 201D A 4' - 0" 7' - 0" WD PREFIN STAIN - - - F1 HM PAINT 5 / A-610 6 / A-610 INT-09 STC-45 201DA A 3' - 0" 7' - 0" WD PREFIN STAIN - - 45 MIN F1 HM PAINT 5 / A-610 6 / A-610 INT-10 STC-50 201E A 3' - 0" 7' - 0" WD PREFIN STAIN - - - F1 HM PAINT 1 / A-610 2 / A-610 INT-02 201F A 3' - 0" 7' - 0" WD PREFIN STAIN - - - F1 HM PAINT 1 / A-610 2 / A-610 INT-17 201G A 3' - 6" 7' - 0" WD PREFIN STAIN - - - F1 HM PAINT 3 / A-610 4 / A-610 INT-03 201GA A 3' - 6" 7' - 0" WD PREFIN STAIN - - - F1 HM PAINT 3 / A-610 4 / A-610 INT-26 201H A 3' - 0" 7' - 0" WD PREFIN STAIN 3/4" - - F1 HM PAINT 1 / A-610 2 / A-610 INT-17 202 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-05 203 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-05 204 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-05
205 A 3' - 0" 7' - 0" HM PAINT - - 45 MIN F1 HM PAINT 3 / A-610 4 / A-610 INT-07
205A B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2 HM PAINT 3 / A-610 4 / A-610 INT-05
206 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2 HM PAINT 3 / A-610 4 / A-610 INT-05
207 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-05 208 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-05 209 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-05
209A B 6' - 0" 7' - 0" HM PAINT - - - F2 HM PAINT 3 / A-610 4 / A-610 INT-28
S1A A 3' - 0" 7' - 0" HM PAINT - - 60 MIN F3 HM PAINT 11 / A-610 12 / A-610 INT-27 S3A A 3' - 0" 7' - 0" HM PAINT - - 60 MIN F3 HM PAINT 11 / A-610 12 / A-610 INT-27
1/4" = 1'-0"
DOOR TYPES
1/4" = 1'-0"
FRAME TYPES
DOOR SCHEDULE - BID OPTION
DOOR
NO.
DOOR
TYPE
DOOR INFORMATION FRAME INFORMATION
HW
SET
SECURITY
DOOR
DETAIL COMMENTS:
SIZE DOOR
MATL
DOOR
FINISH
UNDER
CUT
Glass Type
FIRE
RATING
FRAME
TYPE
FRAME
MATL
FRAME
FINISH
DETAILS
WIDTH HEIGHT HEAD JAMB SILL
111 E 4' - 0" 7' - 0" HM PAINT - - 45 MIN F4 STL PAINT 7/A-611 8/A-611 - EXT-02 CLASS 5A ARMORY DOOR AND
DUTCH-STYLE DAY GATE
M
AR
K
DE
SC
RI
PT
IO
N
DA
TE
AM
EN
DM
EN
T
1/
/2
4 7/8"
PTN WITH 3-5/8"
FRAMING
INSUL AS REQD PER
PTN TYPE INDICATED
HM FRAME AS
SCHED, PNT
DOOR AS SCHED
CONT SNT,
BOTH SIDES 4
7/ 8"
PTN WITH 3-5/8"
FRAMING
INSUL AS REQD PER
PTN TYPE INDICATED
HM FRAME AS
SCHED, PNT,3 AHRS
PER JAMB MIN
DOOR AS SCHED
CONT SNT,
BOTH SIDES
7 1/4"
PTN WITH 6"
FRAMING
INSUL AS REQD PER
PTN TYPE INDICATED
HM FRAME AS
SCHED, PNT
DOOR AS SCHED
CONT SNT,
BOTH SIDES
1/
4"
PTN WITH 6"
FRAMING
INSUL AS REQD PER
PTN TYPE INDICATED
HM FRAME AS
SCHED, PNT, 3 AHRS
PER JAMB, MIN
DOOR AS SCHED
CONT SNT,
BOTH SIDES
8 1/2"
PTN WITH 6"
FRAMING AND DBL
LAYER GWB
INSUL AS REQD PER
PTN TYPE INDICATED
HM FRAME AS
SCHED, PNT
DOOR AS SCHED
CONT SNT,
BOTH SIDES
1/
2"
PTN WITH 6"
FRAMING
INSUL AS REQD PER
PTN TYPE INDICATED
HM FRAME AS
SCHED, PNT, 3 AHRS
PER JAMB MIN
DOOR AS SCHED
CONT SNT,
BOTH SIDES
5 3/4"
SEE PLAN
VARIES
8" CMU
1"
MET STUD OR
FURRING AND
GWB PER PLAN
CONT SNT,
BOTH SIDES
HM FRAME, PNT
DOOR AS
SCHED
3/
4"
SE
E
PL
AN
VA
R
IE
S
DOOR AS SCHED
HM FRAME, PNT
CONT SNT,
BOTH SIDES
8" CMU
MET STUD OR
FURRING AND
GWB PER PLAN
FR AHR
1"
7 1/2" 5 3/4"
DOOR AS SCHED
HM FRAME, GROUT FULL
CMU LINTEL, SEE
STRL DWGS
REINF CMU
CONT SNT & BACKER
ROD BOTH SIDES
STL LINTEL, PAINTED,
SEE STRL DWGS
CONT METAL
FLASHING W/ WEEPS
GROUND FACE
(BURNISHED CMU)
RIGID INSULATION
CONT AIR BARRIER
3/
4"
1/ 2"
PREFABRICATED
GROUND FACE
(BURNISHED) CMU
CORNER UNIT
RIGID INSULATION
CONT AIR BARRIER, TYP
8" REINF CMU
ANCHOR MIN 3 PER JAMB
BULLNOSE, TYP
CONT SNT &
BACKER ROD
BOTH SIDES
DOOR AS
SCHED
HM FRAME
GROUT FULL
5 3/4"
2 1/2"
PREFIN INSUL
MET WALL PNL
MTL WALL
PANEL TRIM
CONT MTL
FLASHING W/ DRIP
CONT SNT &
BACKER ROD
BOTH SIDES
REINF CMU
CMU LINTEL,
SEE STRL DWGS
HM FRAME,
GROUT FULL
DOOR AS SCHED
CONT AIR
BARRIER
3/
4"
MET WALL
PANEL TRIM
PREFIN INSULATED
MET WALL PANEL
CONT AIR BARRIER, TYP
8" REINF CMU
ANCHOR MIN 3 PER JAMB
BULLNOSE, TYP
CONT SNT &
BACKER ROD
BOTH SIDES
DOOR AS
SCHED
HM FRAME
GROUT FULL
1/
2"
8 1/4"
2 3/4"
PREFIN INSUL
MET WALL PNL
MTL WALL
PANEL TRIM
CONT MTL
FLASHING W/ DRIP
CONT SNT &
BACKER ROD
BOTH SIDES
HM FRAME,
GROUT FULL
CONT SNT, ALL
SIDES
MTL STUD
HEADER
2 1/2" THK
SOUND BATTS
5/8" GWB ON 6"
MTL STUDS
1/2" GLASS MAT
SHEATHING
CONT AIR
BARRIER
1/
4"
PREFIN INSUL
MET WALL PNL
MTL WALL
PANEL TRIM
ANCHORS, MIN 3
PER JAMB
HM FRAME,
GROUT FULL
CONT SNT, ALL
SIDES DOUBLE STUDS
@ JAMBS
2 1/2" THK
SOUND BATTS
5/8" GWB ON 6"
MTL STUDS
1/2" GLASS MAT
SHEATHING
CONT AIR
BARRIER
CONT SNT &
BACKER ROD
BOTH SIDES
ALUM DOOR
GLASS AS SCHED
PREFIN MET
CURTAINWALL SYSTEM
1/8"3 1/2"
6"
2 1/2"
DOOR STOP
1/ 8"
1/
2"
6"
1/
2"
PREFIN MET
CURTAINWALL SYSTEM
DOOR STOP
ALUM. DOOR
GLASS AS SCHED
HM FRAME AS
SCHED, PNT
DOOR AS SCHED
REMOVABLE
STOP
GL AS
SCHED
2"
12" 9" 6" 3" 0 3"=1'-0"
12" 9" 6" 3" 0 1' 1-1/2"=1'-0"
US Army Corps of Engineers ® Wilmington District
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
C
AT
EG
O
R Y
C O
D E:
1 2 3 4 5
A
GRAPHIC SCALES
FO
R
T
BR
AG
G
, N O
R
TH
C
AR
O
LI
N A
SO
F
O
PE
R
AT
IO
N
S
FA
C
IL
IT
Y
FY
0, P
N
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
W
IL
M
IN
G
TO
N , N
O R
TH
C
A R
O
LI
N A
AE
C
O M
S
ER
VI
C
E S, IN
C
S J
EF
FE
R
SO
N S
T
ST
E
R
O A
N O
K E
VA
9/
/2
7 8 9 10
B
C
D
E
F
G
TM
J
W
2P M
R
UNCLASSIFIED//FOR OFFICIAL USE ONLY
UNCLASSIFIED//FOR OFFICIAL USE ONLY
W
2H N
-1 4-
D -0
READY TO ADVERTISE (RTA) SUBMISSION
A-610
D O
O R
D
ET
AI
LS
D es ig ne r
Au th or
C he ck er
FY
PN
8A
-6
.d w g
1 1/2" = 1'-0"A-610
1 HEAD DETAIL - 3-5/8" STUD
1 1/2" = 1'-0"A-610
2 JAMB DETAIL - 3-5/8" STUD
1 1/2" = 1'-0"A-610
3 HEAD DETAIL - 6" STUD
1 1/2" = 1'-0"A-610
4 JAMB DETAIL - 6" STUD
1 1/2" = 1'-0"A-610
5 HEAD DETAIL - 6" STUD DBL GWB
1 1/2" = 1'-0"A-610
6 JAMB DETAIL - 6" STUD DBL GWB
1 1/2" = 1'-0"A-610
11 HEAD DETAIL - CMU
1 1/2" = 1'-0"A-610
12 JAMB DETAIL - CMU
1 1/2" = 1'-0"A-610
7 HEAD DETAIL - CMU
1 1/2" = 1'-0"A-610
8 JAMB DETAIL - CMU
1 1/2" = 1'-0"A-610
9 HEAD DETAIL - CMU / MET PANEL
1 1/2" = 1'-0"A-610
10 JAMB DETAIL - CMU / MET PANEL
1 1/2" = 1'-0"A-610
13 HEAD DETAIL - MET PANEL
1 1/2" = 1'-0"A-610
14 JAMB DETAIL - MET PANEL
3" = 1'-0"A-610
16 JAMB DETAIL - CURTAINWALL
3" = 1'-0"A-610
15 HEAD DETAIL- CURTAINWALL
NOTE: SEE AIR BARRIER DETAILS ON SHEET
A-805 FOR DETAILS AT ROUGH OPENINGS
M
AR
K
DE
SC
RI
PT
IO
N
DA
TE
AM
EN
DM
EN
T
1/
/2
1 1/2" = 1'-0"A-610
17 HEAD DETAIL - HM TRANSOM
OCCURS AT FRAME
TYPES F1A AND F2A,
SEE SHEET A-603
FIRST FLOOR
EL 0"
GL-5
6'-10"
6' -6
3'
-6
'-0
2" 6'
-2
2"
2" 6'-6" 2"
FIRST FLOOR
EL 0"
GL-5
9'-6"
2" 5'
-6
2"
5' -1
0" 3'
-6
2" EQ 4'-0" EQ 2"
GL-5GL-5
FIRST FLOOR
EL 0"
GL-5 GL-5GL-5
2" EQ 4'-0" 4'-0" EQ 2"
19'-6"
2" 5'
-6
2"
5' -1
0" 3'
-6
9' -4
GL-5 GL-5GL-5
2" EQ EQ 2" 2'-0"
FIRST FLOOR
EL 0"
GL-5
10'-6"
2" 3'-1" 4'-0" 3'-1" 2"
2" 5'
-6
2"
5' -1
0" 3'
-6
9' -4
GL-5 GL-5
FIRST FLOOR
EL 0"
8'-0"
2" 1'-10" 4'-0" 1'-10" 2"
3' -6
5'
-1 0"
2" 5'
-6
2"
9' -4
GL-5 GL-5 GL-5
FIRST FLOOR
EL 0"
2" 5'
-6
2"
5' -1
0" 3'
-6
9' -4
6'-0" 2" 5'-8" 2"
GL-5
FIRST FLOOR
EL 0"
10'-0"
2" 2'-10" 4'-0" 2'-10" 2"
9' -4
3' -6
5'
-1 0"
2" 5'
-6
2"
GL-5 GL-5 GL-5
FIRST FLOOR
EL 0"
GL-1GL-1 GL-1
32'-0"
2" 7'
-0
2"
1' -8
7'
-4
GL-1 GL-1 GL-1 GL-1
A-621
4 HEAD &
JAMB SIM
4'-6"2"4'-6"2" 2" 4'-6" 2" 4'-6" 2" 4'-6" 2"4'-1"2" 2" 4'-1" 2"
SECOND FLOOR
EL 18'-0"
2" 4'-5" 2"
4'-9"
2" 5'
-6
2"
3' -6
5'
-1 0"
9' -4
GL-5
SECOND FLOOR
EL 18'-0"
2" 5'-2" 2"
5'-6"
2" 5'
-6
2"
5' -1
0" 3'
-6
9' -4
GL-5
SECOND FLOOR
EL 18'-0"
GL-5
2" EQ 4'-0" 4'-0" 4'-0" EQ 2"
GL-5 GL-5GL-5
27'-6 5/8"
2" 5'
-6
2"
5' -1
0" 3'
-6
9' -4
GL-5 GL-5 GL-5
2" EQ 4'-0" EQ 2" 2'-0"
GL-5
SECOND FLOOR
EL 18'-0"
GL-5
16'-11 3/8"
GL-5 GL-5
2" 4'-3 3/4" 8'-0" 4'-3 3/4" 2"
2" 5'
-6
2"
5' -1
0" 3'
-6
9' -4
SECOND FLOOR
EL 18'-0"
GL-5
12'-1" 2" 11'-9" 2"
2" 5'
-6
2"
5' -1
0" 3'
-6
9' -4
GL-5 GL-5
GL-1 - LAMINATED STC-50 SOUND RATED GLASS
GL-2 - FIRE RATED GLAZING
GL-3 - TINTED INSULATED GLASS (LAMINATED)
GL-4 - TINTED INSULATING GLASS (LAMINATED) WITH FROSTED FILM
GL-5 - 1/4" THICK CLEAR TEMP GLASS
GL-6 - SPANDREL GLASS
GL-7 - 1/2" THICK CLEAR LAMINATED GLASS WITH FROSTED FILM
GL-8 - 1/2" THICK TINTED LAMINATED GLASS
GLASS SCHEDULE / TYPES
GENERAL NOTE - GLAZING
FOR GLAZING IN EXTERIOR BUILDING ELEMENTS, DOORS,
WINDOWS, CURTAIN WALLS, AND CLERESTORIES, PROVIDE NO
LESS THAN 1/4" (6MM) NOMINAL POLYCARBONATE OR
LAMINATED GLASS. THE 1/4" (6MM) LAMINATED GLASS CONSISTS
OF TWO NOMINAL 1/8" (3MM) GLASS PANES BONDED TOGETHER
WITH A MINIMUM OF A 0.030" (0.75MM) INTERLAYER OF A
MATERIAL DESIGNED FOR BLAST RESISTANCE IAW UFC 4-010-01,
STANDARD 10. REFER TO SPEC SECTION 08 81 00 GLAZING FOR
MORE INFORMATION.
SECOND FLOOR
EL 18'-0"
14'-3"
2" EQ 4'-0" 4'-0" EQ 2"
3' -6
5'
-1 0"
2" 5'
-6
2"
9' -4
GL-5 GL-5 GL-5 GL-5
4' 2' 0 4' 8' 1/4"=1'-0"
US Army Corps of Engineers ® Wilmington District
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
C
AT
EG
O
R Y
C O
D E:
1 2 3 4 5
A
GRAPHIC SCALES
FO
R
T
BR
AG
G
, N O
R
TH
C
AR
O
LI
N A
SO
F
O
PE
R
AT
IO
N
S
FA
C
IL
IT
Y
FY
0, P
N
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
W
IL
M
IN
G
TO
N , N
O R
TH
C
A R
O
LI
N A
AE
C
O M
S
ER
VI
C
E S, IN
C
S J
EF
FE
R
SO
N S
T
ST
E
R
O A
N O
K E
VA
9/
/2
7 8 9 10
B
C
D
E
F
G
TM
J
W
2P M
R
UNCLASSIFIED//FOR OFFICIAL USE ONLY
UNCLASSIFIED//FOR OFFICIAL USE ONLY
W
2H N
-1 4-
D -0
READY TO ADVERTISE (RTA) SUBMISSION
A-625
IN
TE
R
IO
R W
IN
D
O W
E
LE
VA
TI
O N
S
D es ig ne r
Au th or
C he ck er
FY
PN
8A
-6
.d w g
W20
W21
W22
W23
W24
W25
W26
W27
W28
W30
W32
W33
W31
W29
M
AR
K
DE
SC
RI
PT
IO
N
DA
TE
AM
EN
DM
EN
T
1/
/2
1 1
1 1
ALL INTERIOR WINDOW FRAMES ARE HOLLOW METAL.
SEE DETAILS 1,2,3 & 4 ON SHEET A-621.
US Army Corps of Engineers ® Wilmington District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
C A
T E
G O
R Y
C O
D E
1 2 3 4 5
A
F O
R T
B R
A G
G N
O R
T H
C A
R O
L
IN
A S
O F
O P
E R
A T
IO
N
S F
A C
IL
IT
Y F
Y
P
N
W
IL
M
IN
G T
O N
D
IS
T
R
IC
T W
IL
M
IN
G
T O
N N
O R
T H
C A
R O
L
IN
A
A E
C O
M S
E R
V
IC
E S
IN
C
S
J E
F F
E R
S O
N S
T S
T E
R O
A N
O K
E V
A
/2
/2
7 8 9 10
B
C
D
E
F
G
T M
J
W P
M R
UNCLASSIFIED//FOR OFFICIAL USE ONLY
UNCLASSIFIED//FOR OFFICIAL USE ONLY
W H
N -1
-D
-0
READY TO ADVERTISE (RTA) SUBMISSION
G-003
IN
D
E X
O F
D R
A W
IN
G
S
D e s ig n e r
A u th o r
C h e c k e r
F Y
P
N G
-0 .d w g
INDEX OF DRAWINGS - VOLUME II
SHEET ID FILENAME SHEET TITLE
EL702A FY20PN88658EL702A.dwg SECOND FLOOR NORMAL LIGHTING PLAN POINT BY POINT - AREA A
EL702B FY20PN88658EL702B.dwg SECOND FLOOR NORMAL LIGHTING PLAN POINT BY POINT - AREA B
EL703 FY20PN88658EL703.dwg LIGHTING FIXTURE SCHEDULE
EL711A FY20PN88658EL711A.dwg FIRST FLOOR EMERGENCY LIGHTING PLAN POINT BY POINT -
AREA A
EL711B FY20PN88658EL711B.dwg FIRST FLOOR EMERGENCY LIGHTING PLAN POINT BY POINT -
AREA B
EL712A FY20PN88658EL712A.dwg SECOND FLOOR EMERGENCY LIGHTING PLAN POINT BY POINT -
AREA A
EL712B FY20PN88658EL712B.dwg SECOND FLOOR EMERGENCY LIGHTING PLAN POINT BY POINT -
AREA B
EP101A FY20PN88658EP101A.dwg FIRST FLOOR POWER PLAN - AREA A
EP101B FY20PN88658EP101B.dwg FIRST FLOOR POWER PLAN - AREA B
EP102A FY20PN88658EP102A.dwg SECOND FLOOR POWER PLAN - AREA A
EP102B FY20PN88658EP102B.dwg SECOND FLOOR POWER PLAN - AREA B
EP401 FY20PN88658EP401.dwg ENLARGED POWER PLANS
EP402 FY20PN88658EP402.dwg ENLARGED POWER PLANS
EP403 FY20PN88658EP403.dwg ENLARGED POWER PLANS
ES101 FY20PN88658ES101.dwg ELECTRICAL SITE PLAN
EM101A FY20PN88658EM101A.dwg FIRST FLOOR ELECTRICAL MECHANICAL PLAN - AREA A
EM101B FY20PN88658EM101B.dwg FIRST FLOOR ELECTRICAL MECHANICAL PLAN - AREA B
EM102A FY20PN88658EM102A.dwg SECOND FLOOR ELECTRICAL MECHANICAL PLAN - AREA A
EM102B FY20PN88658EM102B.dwg SECOND FLOOR ELECTRICAL MECHANICAL PLAN - AREA B
EM103A FY20PN88658EM103A.dwg ROOF ELECTRICAL MECHANICAL PLAN - AREA A
EM103B FY20PN88658EM103B.dwg ROOF ELECTRICAL MECHANICAL PLAN - AREA B
E-501 FY20PN88658E-501.dwg ELECTRICAL DETAILS
E-502 FY20PN88658E-502.dwg ELECTRICAL DETAILS
E-503 FY20PN88658E-503.dwg ELECTRICAL DETAILS
E-601 FY20PN88658E-601.dwg ONE-LINE DIAGRAM
E-701 FY20PN88658E-701.dwg ELECTRICAL GENERAL SCHEDULES
E-702 FY20PN88658E-702.dwg ELECTRICAL PANEL SCHEDULES
E-703 FY20PN88658E-703.dwg ELECTRICAL PANEL SCHEDULES
E-704 FY20PN88658E-704.dwg ELECTRICAL PANEL SCHEDULES
E-705 FY20PN88658E-705.dwg ELECTRICAL PANEL SCHEDULES
E-706 FY20PN88658E-706.dwg ELECTRICAL PANEL SCHEDULES
E-707 FY20PN88658E-707.dwg ELECTRICAL PANEL SCHEDULES
E-708 FY20PN88658E-708.dwg ELECTRICAL PANEL SCHEDULES
E-709 FY20PN88658E-709.dwg ELECTRICAL PANEL SCHEDULES
E-710 FY20PN88658E-710dwg ELECTRICAL PANEL SCHEDULES
E-711 FY20PN88658E-711.dwg ELECTRICAL PANEL SCHEDULES
E-712 FY20PN88658E-712.dwg ELECTRICAL PANEL SCHEDULES
E-713 FY20PN88658E-713.dwg ELECTRICAL PANEL SCHEDULES
E-714 FY20PN88658E-714.dwg ELECTRICAL PANEL SCHEDULES
AUDIOVISUAL
TA-001 FY20PN88658TA-001.dwg AUDIOVISUAL GENERAL NOTES, SYMBOLS & ABBREVIATIONS
TA-101A FY20PN88658TA-101A.dwg AUDIOVISUAL FIRST FLOOR PLAN - AREA A
TA-101B FY20PN88658TA-101B.dwg AUDIOVISUAL FIRST FLOOR PLAN - AREA B
TA-102A FY20PN88658TA-102A.dwg AUDIOVISUAL SECOND FLOOR PLAN - AREA A
TA-102B FY20PN88658TA-102B.dwg AUDIOVISUAL SECOND FLOOR PLAN - AREA B
TA-111A FY20PN88658TA-111A.dwg AUDIOVISUAL FIRST FLOOR RCP - AREA A
TA-111B FY20PN88658TA-111B.dwg AUDIOVISUAL FIRST FLOOR RCP - AREA B
TA-112A FY20PN88658TA-112A.dwg AUDIOVISUAL SECOND FLOOR RCP - AREA A
TA-112B FY20PN88658TA-111B.dwg AUDIOVISUAL SECOND FLOOR RCP - AREA B
TA-501 FY20PN88658TA-501.dwg AUDIOVISUAL ELEVATIONS
TA-502 FY20PN88658TA-502.dwg AUDIOVISUAL ELEVATIONS
TA-503 FY20PN88658TA-503.dwg AUDIOVISUAL ELEVATIONS
TA-504 FY20PN88658TA-504.dwg AUDIOVISUAL ELEVATIONS
TA-505 FY20PN88658TA-505.dwg AUDIOVISUAL ELEVATIONS
TA-506 FY20PN88658TA-506.dwg AUDIOVISUAL ELEVATIONS
TA-600 FY20PN88658TA-600.dwg AUDIOVISUAL SCHEDULES
TA-601 FY20PN88658TA-601.dwg AUDIOVISUAL RISER DIAGRAMS
TELECOMMUNICATIONS
T-001 FY20PN88658T-001.dwg TELECOMMUNICATIONS GENERAL NOTES, SYMBOLS &
ABBREVIATIONS
T-100 FY20PN88658T-100.dwg TELECOMMUNICATION SITE PLAN
T-101A FY20PN88658T-101A.dwg TELECOMMUNICATIONS FIRST FLOOR PLAN - AREA A
T-101B FY20PN88658T-101B.dwg TELECOMMUNICATIONS FIRST FLOOR PLAN - AREA B
T-102A FY20PN88658T-103B.dwg TELECOMMUNICATIONS SECOND FLOOR PLAN - AREA A
T-102B FY20PN88658T-102B.dwg TELECOMMUNICATIONS SECOND FLOOR PLAN - AREA B
T-103A FY20PN88658T-103A.dwg TELECOMMUNICATIONS ROOF PLAN - AREA A
T-103B FY20PN88658T-103B.dwg TELECOMMUNICATIONS ROOF PLAN - AREA B
T-111A FY20PN88658T-111A.dwg TELECOMMUNICATIONS FIRST FLOOR REFLECTED CEILING PLAN
- AREA A
T-111B FY20PN88658T-111B.dwg TELECOMMUNICATIONS FIRST FLOOR REFLECTED CEILING PLAN
- AREA B
T-112A FY20PN88658T-112A.dwg TELECOMMUNICATIONS SECOND FLOOR REFLECTED CEILING
PLAN - AREA A
T-112B FY20PN88658TA-112B.dwg TELECOMMUNICATIONS SECOND FLOOR REFLECTED CEILING
PLAN - AREA B
T-112C FY20PN88658T-112C.dwg TELECOMMUNICATIONS SECOND FLOOR SWA RAISED ACCESS
FLOOR PLAN - AREA A
T-401 FY20PN88658T-401.dwg TELECOMMUNICATION ENLARGED PLAN
T-402 FY20PN88658T-402.dwg TELECOMMUNICATION ENLARGED PLAN
T-403 FY20PN88658T-403.dwg TELECOMMUNICATION ENLARGED PLAN
T-404 FY20PN88658T-404.dwg TELECOMMUNICATION ENLARGED PLAN
T-501 FY20PN88658T-501.dwg TELECOMMUNICATION DETAILS
T-502 FY20PN88658T-502.dwg TELECOMMUNICATION DETAILS
T-503 FY20PN88658T-503.dwg TELECOMMUNICATION SCHEDULE
T-504 FY20PN88658T-504.dwg TELECOMMUNICATION SCHEDULE
T-601 FY20PN88658T-601.dwg TELECOMMNICATIONS ONE-LINE DIAGRAM
T-602 FY20PN88658T-602.dwg TELECOMMNUICATION ONE-LINE DIAGRAM
T-603 FY20PN88658T-603.dwg TELECOMUNICATIONS PDS
SECURITY
TY-001 FY20PN88658TY001.dwg SECURITY GENERAL NOTES, SYMBOLS & ABBREVIATIONS
TY-604 FY20PN88658TY604.dwg SECURITY DETAILS
TY-101A FY20PN88658TY10A.dwg SECURITY FIRST FLOOR PLAN - AREA A
TY-101B FY20PN88658T-101B.dwg SECURITY FIRST FLOOR PLAN - AREA B
TY-102A FY20PN88658TY102A.dwg SECURITY SECOND FLOOR PLAN - AREA A
TY-102B FY20PN88658TY102B.dwg SECURITY SECOND FLOOR PLAN - AREA B
TY-103B FY20PN88658T-103B.dwg SECURITY ROOF PLAN - AREA B
INDEX OF DRAWINGS - VOLUME II
SHEET ID FILENAME SHEET TITLE
FIRE ALARM
FA001 FY20PN88658FA001.dwg FIRE ALARM GENERAL NOTES AND LEGEND
FA101A FY20PN88658FA101A.dwg FIRST FLOOR FIRE ALARM FLOOR PLAN - AREA A
FA101B FY20PN88658FA101B.dwg FIRST FLOOR FIRE ALARM FLOOR PLAN - AREA B
FA101C FY20PN88658FA101C.dwg FIRST FLOOR FIRE ALARM FLOOR PLAN - AREA C
FA102A FY20PN88658FA102A.dwg SECOND FLOOR FIRE ALARM FLOOR PLAN - AREA A
FA102B FY20PN88658FA102B.dwg SECOND FLOOR FIRE ALARM FLOOR PLAN - AREA B
FA501 FY20PN88658FA501.dwg FIRE ALARM SEQUENCE OF OPERATIONS MATRIX
FA502 FY20PN88658FA502.dwg FIRE ALARM RISER DIAGRAM
FIRE SUPPRESSION
FX001 FY20PN88658FX001.dwg FIRE SUPPRESSION GENERAL NOTES
FX101A FY20PN88658FX101A.dwg FIRST FLOOR FIRE SUPPRESSION FLOOR PLAN - AREA A
FX101B FY20PN88658FX101B.dwg FIRST FLOOR FIRE SUPPRESSION FLOOR PLAN - AREA B
FX101C FY20PN88658FX101C.dwg FIRE FLOOR FIRE SUPPRESSION FLOOR PLAN - AREA C
FX102A FY20PN88658FX102A.dwg SECOND FLOOR FIRE SUPPRESSION FLOOR PLAN - AREA A
FX102B FY20PN88658FX102B.dwg SECOND FLOOR FIRE SUPPRESSION FLOOR PLAN - AREA B
FX401 FY20PN88658FX401.dwg FIRE SUPPRESSION CLEAN AGENT ENLARGED PLAN AND
SEQUENCE OF OPERATIONS MATRIX
FX501 FY20PN88658FX501.dwg FIRE SUPPRESSION DETAILS
FX502 FY20PN88658FX502.dwg FIRE SUPPRESSION DETAILS
PLUMBING
P-001 FY20PN88658P-001.dwg GENERAL NOTES AND LEGENDS
PU100A FY20PN88658PU100A.dwg UNDERGROUND DWV PLAN - AREA A
PU100B FY20PN88658PU100B.dwg UNDERGROUND DWV PLAN - AREA B
PW101A FY20PN88658PW101A.dwg FIRST FLOOR DWV PLAN - AREA A
PW101B FY20PN88658PW101B.dwg FIRST FLOOR DWV PLAN - AREA B
PW102A FY20PN88658PW102A.dwg SECOND FLOOR DWV PLAN - AREA A
PW102B FY20PN88658PW102B.dwg SECOND FLOOR DWV PLAN - AREA B
PW103A FY20PN88658PW103A.dwg ROOF PLAN - AREA A
PW103B FY20PN88658PW103B.dwg ROOF PLAN - AREA B
PL101A FY20PN88658PL101A.dwg FIRST FLOOR SUPPLY PLAN - AREA A
PL101B FY20PN88658PL101B.dwg FIRST FLOOR SUPPLY PLAN - AREA B
PL102A FY20PN88658PL102A.dwg SECOND FLOOR SUPPLY PLAN - AREA A
PL102B FY20PN88658PL102B.dwg SECOND FLOOR SUPPLY PLAN - AREA B
P-401 FY20PN88658P-401.dwg ENLARGED PLANS
P-501 FY20PN88658P-501.dwg DETAILS
P-502 FY20PN88658P-502.dwg DETAILS
P-503 FY20PN88658P-503.dwg DETAILS
P-504 FY20PN88658P-504.dwg DETAILS
P-601 FY20PN88658P-601.dwg SCHEDULES
P-701 FY20PN88658P-701.dwg RISER DIAGRAMS
P-702 FY20PN88658P-702.dwg RISER DIAGRAMS
MECHANICAL
M-001 FY20PN88658M-001.dwg MECHANICAL LEGEND AND GENERAL NOTES
MH101A FY20PN88658MH101A.dwg FIRST FLOOR DUCT PLAN - AREA A
MH101B FY20PN88658MH101B.dwg FIRST FLOOR DUCT PLAN - AREA B
MH102A FY20PN88658MH102A.dwg SECOND FLOOR DUCT PLAN - AREA A
MH102B FY20PN88658MH102B.dwg SECOND FLOOR DUCT PLAN - AREA B
MH103A FY20PN88658MH103A.dwg ROOF DUCT PLAN - AREA A
MH103B FY20PN88658MH103B.dwg ROOF DUCT PLAN - AREA B
MP101A FY20PN88658MP101A.dwg 1ST FLOOR PIPING PLAN - AREA A
MP101B FY20PN88658MP101B.dwg 1ST FLOOR PIPING PLAN - AREA B
MP102A FY20PN88658MP102A.dwg 2ND FLOOR PIPING PLAN - AREA A
MP102B FY20PN88658MP102B.dwg 2ND FLOOR PIPING PLAN - AREA B
MP103A FY20PN88658M103A.dwg ROOF PIPING PLAN - AREA A
MP103B FY20PN88658M103B.dwg ROOF PIPING PLAN - AREA B
M-301 FY20PN88658M-301.dwg SECTIONS
M-302 FY20PN88658M-302.dwg SECTIONS
M-401 FY20PN88658M-401.dwg ENLARGED FLOOR PLANS
M-402 FY20PN88658M-402.dwg ENLARGED FLOOR PLANS
M-501 FY20PN88658M-501.dwg MECHANICAL DETAILS
M-502 FY20PN88658M-502.dwg MECHANICAL DETAILS
M-503 FY20PN88658M-503.dwg MECHANICAL DETAILS
M-504 FY20PN88658M-504.dwg MECHANICAL DETAILS
M-505 FY20PN88658M-505.dwg MECHANICAL DETAILS
M-601 FY20PN88658M-601.dwg MECHANICAL SCHEDULES
M-602 FY20PN88658M-602.dwg MECHANICAL SCHEDULES
M-603 FY20PN88658M-603.dwg MECHANICAL SCHEDULES
M-604 FY20PN88658M-604.dwg MECHANICAL SCHEDULES
M-701 FY20PN88658M-701.dwg FLOW DIAGRAMS
M-702 FY20PN88658M-702.dwg FLOW DIAGRAMS
M-800 FY20PN88658M-800.dwg CONTROL SYMBOLS & ABBREVIATIONS
M-801 FY20PN88658M-801.dwg CONTROL DIAGRAMS
M-802 FY20PN88658M-802.dwg CONTROL DIAGRAMS
M-803 FY20PN88658M-803.dwg CONTROL DIAGRAMS
M-804 FY20PN88658M-804.dwg CONTROL DIAGRAMS
M-805 FY20PN88658M-805.dwg CONTROL DIAGRAMS
M-806 FY20PN88658M-806.dwg CONTROL DIAGRAMS
M-807 FY20PN88658M-807.dwg CONTROL DIAGRAMS
M-808 FY20PN88658M-808.dwg CONTROL DIAGRAMS
ELECTRICAL
E-001 FY20PN88658E-001.dwg ELECTRICAL LEGEND
EG101A FY20PN88658EG101.dwg FIRST FLOOR GROUNDING PLAN - AREA A
EG101B FY20PN88658EG101B.dwg FIRST FLOOR GROUNDING PLAN - AREA B
EG102A FY20PN88658EG102A.dwg SECOND FLOOR GROUNDING PLAN - AREA A
EG102B FY20PN88658EG102B.dwg SECOND FLOOR GROUNDING PLAN - AREA B
EG103A FY20PN88658EG103A.dwg LIGHTNING PROTECTION PLAN - AREA A
EG103B FY20PN88658EG103B.dwg LIGHTNING PROTECTION PLAN - AREA B
EG400 FY20PN88658EG400.dwg LIGHTNING PROTECTION AND GROUNDING ENLARGED PLAN
EG401 FY20PN88658EG401.dwg SITE LIGHTNING PROTECTION AND GROUNDING PLAN
EG601 FY20PN88658EG601.dwg GROUNDING RISER DIAGRAM
EL101A FY20PN88658EL101A.dwg FIRST FLOOR LIGHTING PLAN - AREA A
EL101B FY20PN88658EL101B.dwg FIRST FLOOR LIGHTING PLAN - AREA B
EL102A FY20PN88658EL102A.dwg SECOND FLOOR LIGHTING PLAN - AREA A
EL102B FY20PN88658EL102B.dwg SECOND FLOOR LIGHTING PLAN - AREA B
EL401 FY20PN88658EL401.dwg LIGHTING SECTIONS
EL402 FY20PN88658EL402.dwg LOBBY AND VESTIBULE LIGHTING PLAN
EL501 FY20PN88658EL501.dwg LIGHTING PLATES
EL502 FY20PN88658EL502.dwg LIGHTING PLATES
EL503 FY20PN88658EL503.dwg LIGHTING PLATES
EL701A FY20PN88658EL701A.dwg FIRST FLOOR NORMAL LIGHTING PLAN POINT BY POINT - AREA A
EL701B FY20PN88658EL701B.dwg FIRST FLOOR NORMAL LIGHTING PLAN POINT BY POINT - AREA B
INDEX OF DRAWINGS - VOLUME I
SHEET ID FILENAME SHEET TITLE
ARCHITECTURE
A-001 FY20PN88658A-001.dwg GENERAL NOTES AND LEGENDS
A-100 FY20PN88658A-100.dwg SECURITY AND STC PLAN
A-101 FY20PN88658A-101.dwg FIRST FLOOR PLAN - OVERALL
A-101A FY20PN88658A-101A.dwg FIRST FLOOR PLAN - AREA A
A-101B FY20PN88658A-101B.dwg FIRST FLOOR PLAN - AREA B
A-102 FY20PN88658A-102.dwg SECOND FLOOR PLAN - OVERALL
A-102A FY20PN88658A-102A.dwg SECOND FLOOR PLAN - AREA A
A-102B FY20PN88658A-102B.dwg SECOND FLOOR PLAN - AREA B
A-103 FY20PN88658A-103.dwg ROOF PLAN
A-111 FY20PN88658A-111.dwg FIRST FLOOR REFLECTED CEILING PLAN - OVERALL
A-111A FY20PN88658A-111A.dwg FIRST FLOOR REFLECTED CEILING PLAN - AREA A
A-111B FY20PN88658A-111B.dwg FIRST FLOOR REFLECTED CEILING PLAN - AREA B
A-112 FY20PN88658A-112.dwg SECOND FLOOR REFLECTED CEILING PLAN - OVERALL
A-112A FY20PN88658A-112A.dwg SECOND FLOOR REFLECTED CEILING PLAN - AREA A
A-112B FY20PN88658A-112B.dwg SECOND FLOOR REFLECTED CEILING PLAN - AREA B
A-122A FY20PN88658A-122A.dwg RAISED ACCESS FLOOR PLAN - AREA A
A-201 FY20PN88658A-201.dwg BUILDING ELEVATIONS
A-202 FY20PN88658A-202.dwg ENLARGED ELEVATIONS
A-203 FY20PN88658A-203.dwg ENLARGED ELEVATIONS
A-204 FY20PN88658A-204.dwg ENLARGED ELEVATIONS
A-205 FY20PN88658A-205.dwg CLERESTORY ELEVATIONS
A-301 FY20PN88658A-301.dwg BUILDING SECTIONS
A-302 FY20PN88658A-302.dwg BUILDING SECTIONS
A-303 FY20PN88658A-303.dwg ENLARGED BUILDING SECTIONS
A-310 FY20PN88658A-310.dwg WALL SECTIONS
A-311 FY20PN88658A-311.dwg WALL SECTIONS
A-312 FY20PN88658A-312.dwg WALL SECTIONS
A-313 FY20PN88658A-313.dwg WALL SECTIONS
A-314 FY20PN88658A-314.dwg WALL SECTIONS
A-315 FY20PN88658A-315.dwg WALL SECTIONS
A-316 FY20PN88658A-316.dwg WALL SECTIONS
A-317 FY20PN88658A-317.dwg WALL SECTIONS
A-401 FY20PN88658A-401.dwg ENLARGED STAIR
A-402 FY20PN88658A-402.dwg ENLARGED STAIR
A-403 FY20PN88658A-403.dwg ENLARGED STAIR
A-404 FY20PN88658A-404.dwg ENLARGED RESTROOM AND ELEVATIONS
A-405 FY20PN88658A-405.dwg ENLARGED LOCKER ROOM AND ELEVATIONS
A-406 FY20PN88658A-406.dwg ENLARGED PLANS AND ELEVATIONS
A-407 FY20PN88658A-407.dwg ENLARGED PLANS AND ELEVATIONS
A-408 FY20PN88658A-408.dwg ENLARGED VESTIBULE
A-410 FY20PN88658A-410.dwg POL STORAGE BUILDING - PLANS AND ELEVATIONS
A-411 FY20PN88658A-411.dwg POL STORAGE BUILDING - SECTIONS
A-501 FY20PN88658A-501.dwg EXTERIOR WALL DETAILS
A-502 FY20PN88658A-502.dwg EXTERIOR WALL BASE DETAILS
A-503 FY20PN88658A-503.dwg CLERESTORY DETAILS
A-504 FY20PN88658A-504.dwg ROOF DETAILS
A-505 FY20PN88658A-505.dwg ROOF DETAILS
A-506 FY20PN88658A-506.dwg ROOF DETAILS
A-510 FY20PN88658A-510.dwg STAIR & RAILING DETAILS
A-511 FY20PN88658A-511.dwg STAIR AND RAILING DETAILS
A-520 FY20PN88658A-520.dwg PLAN DETAILS
A-530 FY20PN88658A-530.dwg INTERIOR DETAILS
A-535 FY20PN88658A-535.dwg CASEWORK DETAILS
A-536 FY20PN88658A-536.dwg CASEWORK DETAILS
A-537 FY20PN88658A-537.dwg CASEWORK DETAILS
A-540 FY20PN88658A-540.dwg TRANSLUCENT WALL DETAIL
A-601 FY20PN88658A-601.dwg PARTITION TYPES
A-602 FY20PN88658A-602.dwg DEMOUNTABLE PARTITION TYPES
A-603 FY20PN88658A-603.dwg DOOR SCHEDULE & DOOR TYPES
A-610 FY20PN88658A-610.dwg DOOR DETAILS
A-611 FY20PN88658A-611.dwg DOOR DETAILS
A-621 FY20PN88658A-621.dwg WINDOW DETAILS
A-622 FY20PN88658A-622.dwg EXTERIOR WINDOW ELEVATIONS
A-623 FY20PN88658A-623.dwg EXTERIOR WINDOW ELEVATIONS
A-625 FY20PN88658A-625.dwg INTERIOR WINDOW ELEVATIONS
A-630 FY20PN88658A-630.dwg EXTERIOR LOUVER ELEVATIONS
A-640 FY20PN88658A-640.dwg MULLION DETAILS
A-801 FY20PN88658A-801.dwg FIRST FLOOR PLAN - AIR BARRIER
A-802 FY20PN88658A-802.dwg SECOND FLOOR PLAN - AIR BARRIER
A-803 FY20PN88658A-803.dwg BUILDING SECTIONS - AIR BARRIER
A-804 FY20PN88658A-804.dwg AIR BARRIER - LONGITUDINAL BUILDING SECTION
A-805 FY20PN88658A-805.dwg AIR BARRIER DETAILS
INTERIORS
IN101 FY20PN88658IN101.dwg FIRST FLOOR FINISH PLAN - OVERALL
IN101A FY20PN88658IN101A.dwg FIRST FLOOR FINISH PLAN - AREA A
IN101B FY20PN88658IN101B.dwg FIRST FLOOR FINISH PLAN - AREA B
IN102 FY20PN88658IN102.dwg SECOND FLOOR FINISH PLAN - OVERALL
IN102A FY20PN88658IN102A.dwg SECOND FLOOR FINISH PLAN - AREA A
IN102B FY20PN88658IN102B.dwg SECOND FLOOR FINISH PLAN - AREA B
IN401 FY20PN88658IN401.dwg ENLARGED FINISH PLANS
IN501 FY20PN88658IN501.dwg TRANSITION DETAILS
IN502 FY20PN88658IN502.dwg TRANSITION DETAILS
IN601 FY20PN88658IN601.dwg FINISH LEGEND
IN602 FY20PN88658IN602.dwg ROOM FINISH SCHEDULE
IF101 FY20PN88658IF101.dwg FIRST FLOOR FURNITURE PLAN - OVERALL
IF101A FY20PN88658IF101A.dwg FIRST FLOOR FURNITURE PLAN - AREA A
IF101B FY20PN88658IF101B.dwg FIRST FLOOR FURNITURE PLAN - AREA B
IF102 FY20PN88658IF102.dwg SECOND FLOOR FURNITURE PLAN - OVERALL
IF102A FY20PN88658IF102A.dwg SECOND FLOOR FURNITURE PLAN - AREA A
IF102B FY20PN88658IF102B.dwg SECOND FLOOR FURNITURE PLAN - AREA B
IF601 FY20PN88658IF601.dwg FURNITURE SCHEDULES
IG101 FY20PN88658IG101.dwg FIRST FLOOR SIGNAGE PLAN - OVERALL
IG101A FY20PN88658IG101A.dwg FIRST FLOOR SIGNAGE PLAN - AREA A
IG101B FY20PN88658IG101B.dwg FIRST FLOOR SIGNAGE PLAN - AREA B
IG102 FY20PN88658IG102.dwg SECOND FLOOR SIGNAGE PLAN - OVERALL
IG102A FY20PN88658IG102A.dwg SECOND FLOOR SIGNAGE PLAN - AREA A
IG102B FY20PN88658IG102B.dwg SECOND FLOOR SIGNAGE PLAN - AREA B
IG601 FY20PN88658IG601.dwg SIGNAGE SCHEDULE
INDEX OF DRAWINGS - VOLUME I
SHEET ID FILENAME SHEET TITLE
GENERAL
G-001.1 FY20PN88658G-001.1.dwg COVER SHEET - VOLUME I
G-001.2 FY20PN88658G-001.2.dwg COVER SHEET - VOLUME II
G-002 FY20PN88658G-002.dwg FT. BRAGG CANTONMENT
G-003 FY20PN88658G-003.dwg INDEX OF DRAWINGS
G-004 FY20PN88658G-003.dwg ABBREVIATIONS
G-005 FY20PN88658G-004.dwg GENERAL SYMBOLOGY
G-006 FY20PN88658G-005.dwg TYPICAL MOUNTING HEIGHTS
LIFE SAFETY
GI001 FY20PN88658GI001.dwg LIFE SAFETY CODE ANALYSIS
GI002 FY20PN88658GI002.dwg EMERGENCY VEHICLE ACCESS
GI101 FY20PN88658GI101.dwg FIRST FLOOR LIFE SAFETY PLAN
GI102 FY20PN88658GI102.dwg SECOND FLOOR LIFE SAFETY PLAN
CIVIL
VF100 FY20PN88658VF100.dwg SURVEY & NOTES
VF101 FY20PN88658VF101.dwg EXISTING TOPOGRAPHY 1
VF102 FY20PN88658VF102.dwg EXISTING TOPOGRAPHY 2
B-101 FY20PN88658B-101.dwg BORING LOCATION PLAN 1
B-102 FY20PN88658B-102.dwg BORING LOCATION PLAN 2
BB601 FY20PN88658BB601.dwg SOIL TEST BORING LOGS 1
BB602 FY20PN88658BB602.dwg SOIL TEST BORING LOGS 2
BB603 FY20PN88658BB603.dwg SOIL TEST BORING LOGS 3
BB604 FY20PN88658BB604.dwg SOIL TEST BORING LOGS 4
BB605 FY20PN88658BB605.dwg SOIL TEST BORING LOGS 5
BB606 FY20PN88658BB606.dwg SOIL TEST BORING LOGS 6
CD101 FY20PN88658CD101.dwg SITE DEMOLITION PLAN 1
CD102 FY20PN88658CD102.dwg SITE DEMOLITION PLAN 2
CS101 FY20PN88658CS101.dwg SITE UTILITIES PLAN 1
CS102 FY20PN88658CS102.dwg SITE UTILITIES PLAN 2
CS201 FY20PN88658CS201.dwg SIGNAGE & MARKINGS PLAN 1
CS202 FY20PN88658CS202.dwg SIGNAGE & MARKINGS PLAN 2
CS501 FY20PN88658CS502.dwg SITE DETAILS 1
CS502 FY20PN88658CS502.dwg SITE DETAILS 2
CG101 FY20PN88658CG101.dwg SITE GRADING PLAN 1
CG102 FY20PN88658CG102.dwg SITE GRADING PLAN 2
CG103 FY20PN88658CG103.dwg STORM DRAINAGE PLAN 1
CG104 FY20PN88658CG104.dwg STORM DRAINAGE PLAN 2
CG105 FY20PN88658CG105.dwg EROSION CONTROL PHASE I PLAN 1
CG106 FY20PN88658CG106.dwg EROSION CONTROL PHASE I PLAN 2
CG107 FY20PN88658CG107.dwg EROSION CONTROL PHASE II PLAN 1
CG108 FY20PN88658CG108.dwg EROSION CONTROL PHASE II PLAN 2
CG109 FY20PN88658CG109.dwg EROSION CONTROL PHASE III PLAN 1
CG110 FY20PN88658CG110.dwg EROSION CONTROL PHASE III PLAN 2
CG201 FY20PN88658CG201.dwg STORM DRAINAGE PROFILES 1
CG202 FY20PN88658CG202.dwg STORM DRAINAGE PROFILES 2
CG501 FY20PN88658CG501.dwg STORM DRAINAGE DETAILS
CG502 FY20PN88658CG502.dwg STORM DRAINAGE DETAILS 2
CG503 FY20PN88658CG503.dwg STORM DRAINAGE DETAILS 3
CG504 FY20PN88658CG504.dwg STORM DRAINAGE DETAILS 4
CG505 FY20PN88658CG505.dwg N.P.D.E.S. CHECKLIST 1
CG506 FY20PN88658CG506.dwg N.P.D.E.S CHECKLIST 2
CG507 FY20PN88658CG507.dwg EROSION CONTROL DETAILS & NOTES 1
CG508 FY20PN88658CG509.dwg EROSION CONTROL DETAILS & NOTES 2
CG509 FY20PN88658CG509.dwg EROSION CONTROL DETAILS & NOTES 3
CG510 FY20PN88658CG510.dwg EROSION CONTROL DETAILS & NOTES 4
CG511 FY20PN88658CG511.dwg EROSION CONTROL DETAILS & NOTES 5
CG512 FY20PN88658CG512.dwg EROSION CONTROL DETAILS & NOTES 6
CG513 FY20PN88658CG513.dwg EROSION CONTROL DETAILS & NOTES 7
CG514 FY20PN88658CG514.dwg EROSION CONTROL DETAILS & NOTES 8
CG515 FY20PN88658CG515.dwg EROSION CONTROL DETAILS & NOTES 9
CG516 FY20PN88658CG516.dwg EROSION CONTROL DETAILS & NOTES 10
CG517 FY20PN88658CG517.dwg EROSION CONTROL DETAILS & NOTES 11
CG518 FY20PN88658CG518.dwg EROSION CONTROL DETAILS & NOTES 12
CG519 FY20PN88658CG519.dwg ADDITIONAL NOTES
CU201 FY20PN88658CU201.dwg SITE UTILITIES PLAN 1
CU202 FY20PN88658CU202.dwg SITE UTILITIES PLAN 2
CU203 FY20PN88658CU203.dwg SANITARY SEWER PROFILES
CU501 FY20PN88658CU501.dwg SANITARY SEWER DETAILS 1
CU502 FY20PN88658CU502.dwg SANITARY SEWER DETAILS 2
CU503 FY20PN88658CU503.dwg WATER DETAILS
L-101 FY20PN88658L-101.dwg LANDSCAPING PLAN 1
L-102 FY20PN88658L-102.dwg LANDSCAPING PLAN 2
STRUCTURAL
S-001 FY20PN88658S-001 GENERAL NOTES
S-002 FY20PN88658S-002 WIND C&C DIAGRAM
S-101 FY20PN88658S-101 FOUNDATION PLAN - OVERALL
S-101A FY20PN88658S-101A FOUNDATION PLAN - AREA A
S-101B FY20PN88658S-101B FOUNDATION PLAN - AREA B
S-102 FY20PN88658S-102 SECOND FLOOR FRAMING PLAN - OVERALL
S-102A FY20PN88658S-102A SECOND FLOOR FRAMING PLAN - AREA A
S-102B FY20PN88658S-102B SECOND FLOOR FRAMING PLAN - AREA B
S-103 FY20PN88658S-103 ROOF FRAMING PLAN - OVERALL
S-103A FY20PN88658S-103A ROOF FRAMING PLAN - AREA A
S-103B FY20PN88658S-103B ROOF FRAMING PLAN - AREA B
S-201 FY20PN88658S-201 BRACED FRAME ELEVATIONS
S-202 FY20PN88658S-202 BRACED FRAME ELEVATIONS
S-203 FY20PN88658S-203 TRUSS ELEVATIONS
S-301 FY20PN88658S-301 SECTION & DETAILS
S-302 FY20PN88658S-302 SECTION & DETAILS
S-303 FY20PN88658S-303 SECTION & DETAILS
S-304 FY20PN88658S-304 SECTION & DETAILS
S-305 FY20PN88658S-305 SECTION & DETAILS
S-306 FY20PN88658S-306 SECTION & DETAILS
S-307 FY20PN88658S-307 SECTION & DETAILS
S-308 FY20PN88658S-308 SECTION & DETAILS
S-309 FY20PN88658S-309 SECTION & DETAILS
S-310 FY20PN88658S-310 SECTION & DETAILS
S-311 FY20PN88658S-311 SECTION & DETAILS
S-401 FY20PN88658S-401 ENLARGED PLANS
S-402 FY20PN88658S-402 ENLARGED PLANS
S-403 FY20PN88658S-403 ENLARGED PLANS - AREA C
S-404 FY20PN88658S-404 ENLARGED PLAN - BID OPTION 1
S-501 FY20PN88658S-501 TYPICAL DETAILS
S-502 FY20PN88658S-502 TYPICAL DETAILS
S-503 FY20PN88658S-503 TYPICAL DETAILS
S-504 FY20PN88658S-504 TYPICAL DETAILS
S-601 FY20PN88658S-601 SCHEDULES
SHEET TA111B
REMOVED BY WAY
OF AMENDMENT 0005
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A m e n d m e n t
J
A N
US Army Corps of Engineers ® Wilmington District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
C A
T E
G O
R Y
C O
D E
1 2 3 4 5
A
F O
R T
B R
A G
G N
O R
T H
C A
R O
L
IN
A S
O F
O P
E R
A T
IO
N
S F
A C
IL
IT
Y F
Y
P
N
W
IL
M
IN
G T
T
R
IC
T W
IL
M
IN
G
T O
N N
O R
T H
C A
R O
L
IN
A
A E
C…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .