PN 88658 SOF Operations Facility Federal contract opportunity
Solicitation number
W912PM20R0009
Issued by
Department of the Army Corps of Engineers Engineering District Wilmington

About this file

This is a solicitation for construction services. The selected contractor will construct a SOF Operations Facility including administrative areas, mission planning spaces, vehicle bays, climate controlled storage, petroleum storage, arms vaults, individual unit storage, workshops, latrines with lockers, and laundry. The facility will also include a Secure Compartmentalized Information Facility with administrative area, classroom, operations center, and Special Access Programs spaces. The project scope includes fire alarm, suppression, security, communications, and audiovisual systems. Sustainability, accessibility, and cybersecurity measures will be incorporated. Supporting site work includes utilities, lighting, storm drainage, landscaping, and fencing. The Army Corps of Engineers Engineering District Wilmington is the issuing agency. Responses were due under Solicitation Number W912PM20R0009.

View the file

Other files for this federal contract opportunity

Other files attached to PN 88658 SOF Operations Facility, newest first.
File Type Posted
W912PM20R0009-00005 Amendment.pdf PDF
AMDT0005_PN88658-Specs VOL 2.pdf PDF
AMDT0005_PN88658-Specs VOL 3 - FFE-SID.pdf PDF
Site Visit sign in Sheet 2 of 2 12092020.jpg JPG image
AMDT0004_PN88658-Specs VOL 2.pdf PDF
AMDT0004_PN88658-Specs VOL 3 - FFE-SID.pdf PDF
W912PM20R00090004_Conformed.docx.pdf PDF
AMDT0004_PN88658-Specs VOL 2.pdf PDF
AMDT0004_PN88658-Specs VOL 3 - FFE-SID.pdf PDF
W912PM20R00090004_Modification 4.docx.pdf PDF
W912PM20R00090003_Conformed.docx.pdf PDF
AMDT0004_PN88658-Specs VOL 3 - FFE-SID.pdf PDF
88658_ADMT004_Summary-of-Changes_Final.pdf PDF
AMDT0004_PN88658-Specs VOL 1.pdf PDF
88658_AMD-0004-Conformed_Dwgs.pdf PDF
AMDT0004_PN88658-Specs VOL 2.pdf PDF
AMDT0003_PN88658 - RTA Specs VOL 2 Cover Sheet - 9.21.2020 - Corrected Solicitation No.pdf PDF
W912PM20R00090003_Conformed.pdf PDF
W912PM20R00090003.pdf PDF
AMDT0003_PN88658-Specs VOL 3 - FFE-SID.pdf PDF
AMDT0003_PN88658-Specs VOL 1.pdf PDF
AMDT0003_PN88658_2020.12.22_Spec Sec 09 29 00 Gypsum Board.pdf PDF
AMDT0003_PN88658-Specs VOL 2.pdf PDF
AMDT0003_PN88658 - RTA Specs VOL 1 Cover Sheet - 9.21.2020 - Corrected Solicitation No.pdf PDF
2020.12.18-AMD-0002-88658_Technical_Summary_of_Changes.pdf PDF
W912PM20R00090002_Conformed.pdf PDF
AMDT0002_PN88658-Specs VOL 2.pdf PDF
W912PM20R00090002.pdf PDF
AMDT0002_88658_03-17_O190U_Repair_1994_Combined_Asblts.pdf PDF
AMDT0002_PN88658-Specs VOL 1.pdf PDF
2020.12.17 - AMD-0002 - Sheet CU201.pdf PDF
AMDT0002_PN88658-Specs VOL 3 - FFE-SID.pdf PDF
20R0009 Amendment 1 Clauses CCopy.docx.pdf PDF
20R0009 Amendment 1 Clauses.docx.pdf PDF
PN 88658 Site Visit Map.pdf PDF
PN_88658_JA Siemon_2ndversion_20201110 v1.2.pdf PDF
PN88658 RTA SOTF Drawings Vol 2 (LOCKED).pdf PDF
PN88658 - RTA Specs VOL 1 2nd Version 23Nov2020.pdf PDF
PN88658 RTA SOTF Drawings Vol 1 (LOCKED).pdf PDF
PN_88658_JA_Security_Solutions_20201110 v1.2.pdf PDF
PN_88658_JA_Corning_20201117 v1.2.pdf PDF
PN88658 - RTA Specs VOL 1.pdf PDF
PN88658 - RTA Specs VOL 3 - FFE-SID.pdf PDF
PN88658 RTA SOTF Drawings Vol 1.pdf PDF
PN88658 RTA SOTF Drawings Vol 2.pdf PDF
PN_88658_JA Siemon_20201110 v1.2.pdf PDF
PN_88658_JA Honeywell_20201110 v1.2 (1).pdf PDF
W912PM20R0009 PN88658 Solicitation.pdf PDF
PN88658 - RTA Specs VOL 2.pdf PDF
NAVFAC-USACE PPQ (fillable).pdf PDF
Show all 50

PN 88658 SOF Operations Facility has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Solicitation #W912-PM-20-R-0009 88658 - SOF Operations Facility - Fort Bragg, North Carolina Amendment No. 0005 Date: 20 JAN 2021

SUMMARY OF CHANGES

1. CHANGES TO SPECIFICATIONS. Attached hereto are [new, revised and deleted] sections to the specifications. Revised sections replace like numbered sections. Revised pages replace likenumbered pages. Revision mark “****Amendment 0005****” is shown on each revised page.

A. REVISED SECTIONS. The following revised sections replace like numbered sections.

Changes to text are indicated by underline and/or strike-through.

PROJECT TABLE OF CONTENTS (Revised to delete reference to Section 10 26 00) 00 01 15 LIST OF DRAWINGS w/Revised Attachment.

01 14 00 WORK RESTRICTIONS

01 91 00.00 37 COMMISSIONING w/New Attachment.

07 27 10.00 10 BUILDING AIR BARRIER SYSTEM

08 44 00 CURTAIN WALL, GLAZED ASSEMBLIES AND SUN CONTROL

08 81 00 GLAZING

B. NEW SECTIONS. The following sections are added to the specifications: None.

C. DELETED SECTIONS: The following sections are deleted from the specifications:

10 26 00 WALL AND DOOR PROTECTION.

2. CHANGES TO DRAWINGS. Attached hereto are [new and revised] drawing sheets. Revised sheets replace like-numbered sheets. The revision tracker in the Title Block of each sheet is populated to reflect the current Amendment Number and issue date.

A. REVISED DRAWINGS (ISSUED). The following revised drawings replace like numbered drawings and are issued herewith:

Sheet ID Volume Mark Revision Date A-601 Volume 1 1 01/19/2021 A-603 Volume 1 1 01/19/2021 A-610 Volume 1 1 01/19/2021 A-625 Volume 1 1 01/19/2021 G-003 Volume 1 1 01/19/2021 G-003 Volume 2 1 01/19/2021 IN101A Volume 1 2 01/19/2021 IN101B Volume 1 1 01/19/2021 IN102A Volume 1 1 01/19/2021 IN102B Volume 1 1 01/19/2021 M-503 Volume 2 1 01/19/2021 TY-001 Volume 2 1 01/19/2021

Solicitation #W912-PM-20-R-0009 88658 - SOF Operations Facility - Fort Bragg, North Carolina Amendment No. 0005 Date: 20 JAN 2021

SUMMARY OF CHANGES Cont.

B. NEW DRAWINGS (ISSUED). The following new drawings are added to the drawing set and are issued herewith:

Sheet ID Volume Mark Date TA-112B Volume 2 1 01/19/2021

…end of summary…

A. REFER TO SHEET G-004 FOR ABBREVIATIONS.

B. REFER TO SHEET A-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS.

C. REFER TO LIFE SAFETY PLANS FOR REQUIRED FIRE RATED PARTITION LOCATION.

D. SMOKE AND/OR FIRE RATED PARTITIONS SHALL BE CONSTRUCTED PER THE REQUIREMENTS OF THE U.L.

TEST ASSEMBLY IDENTIFIED. PARTITIONS SHALL EXTEND FROM STRUCTURAL SLAB TO STRUCTURAL SLAB. PROVIDE CONTINUOUS FIRE STOPPING/ SEALANT BOTH SIDES, TOP AND BOTTOM, AND AT ALL

PENETRATIONS.

E. ALL FIRE BARRIERS AND FIRE PARTITIONS SHALL BE DESIGNATED ABOVE THE CEILING AND ON ALL CEILING ACCESS DOORS WHICH PROVIDE ACCESS TO SUCH FIRE RATED ASSEMBLIES BY SIGNAGE HAVING LETTERS NO SMALLER THAN 1 INCH IN HEIGHT. SUCH SIGNAGE SHALL INDICATE THE FIRE RESISTANCE OF THE ASSEMBLY AND THE TYPE OF ASSEMBLY, AND BE PROVIDED AT HORIZONTAL

INTERVALS OF NO MORE THAN EIGHT FEET.

F. ALL FULL HEIGHT PARTITIONS SHALL PROVIDE FOR VERTICAL MOVEMENT AT THE STRUCTURAL JOINT AT THE SLAB ABOVE. ALL METAL STUD PARTITIONS SHALL BE CONSTRUCTED WITH A SLIP JOINT BETWEEN STUDS AND THE TOP RUNNER TRACK OR USE A SLOTTED DEFLECTION TRACK THAT ALLOWS FOR A

MAXIMUM STRUCTURAL DEFLECTION OF 3/4". SEAL ALL JOINTS TOP AND BOTTOM.

G. PROVIDE METAL OR SOLID FRT WD BLOCKING AT PARTITIONS AS REQUIRED TO ACCOMMODATE INSTALLATION OF CASEWORK, LOCKERS, GRAB BARS, HANDRAILS, AV EQUIPMENT, SIGNAGE AND OTHER

WALL MOUNTED SCHEDULED EQUIPMENT AND ACCESSORIES.

H. GYPSUM BOARD PARTITIONS SPANNING ABOVE DOOR/WINDOW OPENINGS 6'-0" WIDE OR MORE SHALL BE

DIAGONALLY BRACED AT 6'-0" OC.

I. ALL METAL STUD SPACING SHALL BE 16" OC UNO.

J. PROVIDE GWB CONTROL JOINTS AND CONSTRUCT IN ACCORDANCE WITH GYPSUM ASSOCIATION GA

216-2016 AND AS INDICATED ON THE DRAWINGS. AT CONTROL JOINTS IN RATED PARTITIONS OR AT

CONTROL JOINTS IN STC 45 WALLS AND GREATER, REFER TO DETAIL 1 ON SHT A-601.

K. PROVIDE MOISTURE RESISTANT GWB AT ALL PARTITIONS AND SHAFT WALLS WITH WATER CLOSETS, URINALS, LAVATORIES, UTILITY SINKS, MOP BASINS, ELECTRIC WATER COOLERS AND WHERE

SCHEDULED TO RECEIVE EPOXY PAINT.

L. PROVIDE ABUSE RESISTANT GWB TO 8'-0" AFF AT ALL CORRIDORS, LOBBY, VESTIBULE, VEHICLE BAY 100D, STAGING AREA 100E, STAGING 200B AND STAGING 200F.

M. ALL GYPSUM BOARD SHALL BE 5/8" TYPE "X" UNO.

N. ALL INTERIOR PARTITIONS SHALL BE TYPE P21 UNO.

O. ALL VERTICAL MEP SHAFTS/CHASES SHALL BE TYPE P52, 2-HR FIRE RATED SHAFTWALL UNO.

P. THE CONTRACTOR SHALL PERFORM FIELD TESTING TO CERTIFY THAT THE ACOUSTICAL WALL

CONSTRUCTION INDICATED HAS BEEN MET. THE CONTRACTOR MAY CHOOSE TO USE EITHER NOISE ISOLATION CRITERIA (NIC) OR FIELD SOUND TRANSMISSION CLASS (FSTC) TESTING TO DETERMINE FIELD RATINGS OF CONSTRUCTED SOUND RATED PARTITIONS. CONTRACTOR TESTING MUST COMPLY WITH

ICD/ICS 705 REQUIREMENTS. SUBMIT TESTING EQUIPMENT AND PROCESSES TO BE USED TO

CONTRACTING OFFICER FOR APPROVAL. WALLS TESTED MUST HAVE A SOUND RATING OF NIC OR FSTC 45 AT STC 50 PARTITIONS, AND NIC OR FSTC 40 AT STC 45 PARTITIONS. THE CONTRACTOR WILL BE RESPONSIBLE FOR PERFORMING REMEDIAL WORK TO MEET THE REQUIRED FIELD SOUND RATINGS.

Q. GOVERNMENT WILL PERFORM INDEPENDENT SOUND TESTING IN ADDITION TO CONTRACTOR'S SOUND

TESTING. CONTRACTOR WILL BE RESPONSIBLE FOR PERFORMING REMEDIAL WORK TO MEET THE

REQUIRED FIELD SOUND RATINGS RESULTING FROM GOVERNMENT TESTING.

R. LOCATE DEVICES IN ACOUSTICAL PARTITIONS IN A MANNER THAT MAINTAINS THE ACOUSTICAL

PROPERTIES OF THE PARTITION. REFER TO DETAIL 2 ON A-601.

S. LABEL FIRE RATED AND SMOKE RATED PARTITIONS WITH STENCILING OR SIGNS. LOCATE

IDENTIFICATION BELOW RAISED ACCESS FLOOR AND ABOVE ACCESSIBLE CEILINGS. SPACE

IDENTIFICATION AT NO MORE THAN 10 FEET ON CENTER MEASURED HORIZONTALLY ALONG THE

PARTITION. INCORPORATE LETTERING NOT LESS THAN 1 INCH IN HEIGHT. LABEL WITH RESISTANCE

RATING (E.G. "1 HOUR FIRE RATED PARTITION, PROTECT ALL OPENINGS").

GENERAL NOTES THIS SHEET:

Top

Plan

Base

Top

Plan

Base

(1) LAYER 5/8"

GYPSUM BOARD

ONE SIDE

1 1/2" METAL STUDS @

16" O.C. @ P01. 7/8"

METAL HAT CHANNEL

FURRING @16" O.C. @

P01A (1) LAYER 5/8" GYPSUM

BOARD EACH SIDE

6" METAL STUDS @ 16"

O.C.

UNDERSIDE OF

STRUCTURE

PROVIDE SLOTTED

DEFLECTION

TRACK ASSEMBLY

RUNNER TRACK

CEILING AS SCHED -

SEE FINISH SCHEDULE

(1) LAYER 5/8"

GYPSUM BOARD ONE

SIDE

2 1/2" METAL STUDS @

16" O.C.

RUNNER TRACK

CEILING AS SCHED -

SEE FINISH SCHEDULE

3" SOUND

ATTENUATION

INSULATION

P01 1 1/2" METAL STUDS @ 16" O.C. P21 6" METAL STUDS @ 16" O.C., SMOKE TIGHT W/

ACOUSTICAL BATT INSULATION

P21A 6" METAL STUDS @ 16" O.C., SMOKE TIGHT W/ NO

ACOUSTICAL BATT INSULATION

FLOOR AND BASE AS

SCHED - SEE FINISH

SCHEDULE

FLOOR AND BASE AS

SCHED - SEE FINISH

SCHEDULE

FLOOR AND BASE AS

SCHED - SEE FINISH

SCHEDULE

(1) LAYER 5/8"

GYPSUM BOARD ONE

SIDE

3 5/8" 20 GAUGE

METAL STUDS @ 16"

O.C.

RUNNER TRACK

CEILING AS SCHED - SEE

FINISH SCHEDULE

P12A 2 1/2" METAL STUDS @ 16" O.C.

FLOOR AND BASE AS

SCHED - SEE FINISH

SCHEDULE

CEILING AS SCHED - SEE

FINISH SCHEDULE

P02 2 1/2" METAL STUDS @ 16" O.C.

(1) LAYER 5/8" GYPSUM

BOARD EACH SIDE

3 5/8" METAL STUDS @

16" O.C.

UNDERSIDE OF

STRUCTURE

PROVIDE SLOTTED

DEFLECTION

TRACK ASSEMBLY

RUNNER TRACK

3" SOUND

ATTENUATION

INSULATION

P22 3 5/8" METAL STUDS @ 16" O.C. W/ ACOUSTICAL BATT

INSULATION

P22A 3 5/8" METAL STUDS @ 16" O.C. W/ NO ACOUSTICAL BATT

INSULATION

P22B 6" METAL STUDS @ 16" O.C. W/ ACOUSTICAL

BATT INSULATION

FLOOR AND BASE AS

SCHED - SEE FINISH

SCHEDULE

CEILING AS SCHED - SEE

FINISH SCHEDULE

UNDERSIDE OF

STRUCTURE

PROVIDE SLOTTED

DEFLECTION

TRACK ASSEMBLY

P52 STC 50; 2 1/2" C-H STUDS

"J" RUNNER TRACK

FLOOR AND BASE AS

SCHED - SEE FINISH

SCHEDULE

FIRESTOP SEALANT,

TOP & BOT.

3" MINERAL WOOL

BATT INSUL

UL DESIGN NO. U415 - SYSTEM B, 2 HOUR SYSTEM

STC 50 - SOUND TEST RAL-OT04-019 W/ MINERAL WOOL

2 1/2" OR 4" VENTED 20

GAUGE METAL CH STUDS

@ 24" O.C.

(2) LAYERS 5/8" TYPE "X"

OR (1) LAYER 1/2"

FIRECODE TYPE "C"

GYPSUM BOARD

(1) LAYER 1" X 24" TYPE "X"

GYPSUM LINER PANEL

UNDERSIDE OF

STRUCTURE

FIRESAFE / SEAL TIGHT

TO DECK, SEE NOTES

PROVIDE SLOTTED DEFLECTION

TRACK ASSEMBLY

CEILING AS SCHED - SEE

FINISH SCHEDULE

P61 8" CMU W/ 7/8" FURRING AND 5/8" GWB ONE SIDE ONLY

FLOOR AND BASE AS

SCHED - SEE FINISH

SCHEDULE

7/8" METAL HAT CHANNEL

FURRING @16" O.C. ONE

SIDE ONLY

(1) LAYER 5/8" GWB, ONE

SIDE ONLY

8" NOMINAL CMU

UNDERSIDE OF

STRUCTURE

CEILING AS SCHED - SEE

FINISH SCHEDULE

6" 6"

6"

6"

6"

P12B 3 5/8" METAL STUDS @ 16" O.C.

(2) LAYERS 5/8" TYPE

"X" GYPSUM BOARD

EACH SIDE

6" METAL STUDS @

16" O.C.

3" SAFB SOUND

ATTENUATION

FIRE BLANKET

UNDERSIDE OF

STRUCTURE

FIRESAFE / SEAL TIGHT

TO DECK, SEE NOTES

PROVIDE SLOTTED

DEFLECTION

TRACK ASSEMBLY

UL DESIGN NO. U411 OR U419 - 1 HOUR SYSTEM W/

UL SYSTEM NO. HW-D-0060 AT HEAD JOINT

P41 6" METAL STUDS; STC 50

CEILING AS SCHED - SEE

FINISH SCHEDULE

RAISED ACCESS

FLOOR WHERE

OCCURS

FLOOR AND BASE AS

SCHED - SEE FINISH

SCHEDULE

FIRESTOP SEALANT,

TOP & BOT.

P41A 6" METAL STUDS; STC 45

P81 8" CAST-IN-PLACE CONCRETE

FLOOR AND BASE AS

SCHED - SEE FINISH

SCHEDULE

8" CAST-IN-PLACE CONC - SEE

STRL

UNDERSIDE OF

STRUCTURE

CONC CEILING - SEE STRL

(1) LAYER 5/8" GYPSUM BOARD

LAMINATED TO CONC

CONC SLAB

BID OPTION 1

(1) LAYER 5/8" TYPE "X"

GYPSUM BOARD EACH

SIDE

3 5/8" OR 6" METAL

STUDS @ 16" O.C.

3" SAFB SOUND

ATTENUATION

FIRE BLANKET

UNDERSIDE OF

STRUCTURE

FIRESAFE / SEAL TIGHT

TO DECK, SEE NOTES

PROVIDE SLOTTED

DEFLECTION

TRACK ASSEMBLY

RUNNER TRACK

UL DESIGN NO. U419 - 1 HOUR SYSTEM W/

UL SYSTEM NO. HW-D-0060 AT HEAD JOINT

STC 49 - SOUND TEST SA-870717

P23 1 HR FIRE/SMOKE BARRIER UL DESIGN NO. U419

P23A 1 HR FIRE/SMOKE BARRIER UL DESIGN NO. U419 W/ 6"

METAL STUDS @ 16" O.C.

FLOOR AND BASE AS

SCHED - SEE FINISH

SCHEDULE

CEILING AS SCHED - SEE

FINISH SCHEDULE

FIRESTOP SEALANT, TOP

& BOT.

P23B NON-FIRE-RATED P23 UL DESIGN NO. U419

STC-45 (NIC-40) SOUND RATED SA-870717

P41B 6" METAL STUDS; STC 45

P41D 6" METAL STUDS; STC 50; 1 HR

FIRE/SMOKE BARRIER UL

DESIGN NO. U419

P12C 6" METAL STUDS @ 16" O.C.

RUNNER TRACK

P01A 7/8" METAL HAT CHANNEL

@ 16" O.C.

P61A SAME AS P61 BUT NO FURRING OR GWB

P61B SAME AS P61 BUT 1 HR FIRE/SMOKE BARRIER

UL DESIGN NO U910

UL DESIGN NO. U910 - 1 HOUR SYSTEM W/ UL

SYSTEM AT HEAD JOINT

BATT INSUL

PER PTN TYPE

MET. FRAMING

PER PTN TYPE

GWB PER

PTN TYPE

GWB PER

PTN TYPE

1/2" MAX

2 LAYERS 5/8" GWB

GWB CJ

5/8" GAP CONT SNT

BATT INSUL PER PTN TYPE

MET. FRAMING PER PTN TYPE

GWB PER PTN TYPE

ACOUSTIC PUTTY PAD AT

DEVICE BACKBOXES (@ ALL

SIDES), TYP

ACOUSTIC SEALANT

BETWEEN EDGE OF WALL AND

BACKBOX (@ ALL SIDES), TYP

GENERAL NOTE: DETAIL APPLIES TO

BACKBOXES IN ALL PARTITIONS

SCHEDULED TO HAVE STC RATINGS.

DEVICE BACKBOX, TYP

1'-6" MIN

US Army Corps of Engineers ® Wilmington District

SHEET ID

U S

AR

M

Y C

O R

P S

O F

EN

G

IN

E

ER

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

C

AT

EG

O

R Y

C O

D E:

1 2 3 4 5

A

FO

R

T

BR

AG

G

, N O

R

TH

C

AR

O

LI

N A

SO

F

O

PE

R

AT

IO

N

S

FA

C

IL

IT

Y

FY

0, P

N

W

IL

M

IN

G

TO

N D

IS

TR

IC

T

W

IL

M

IN

G

TO

N , N

O R

TH

C

A R

O

LI

N A

AE

C

O M

S

ER

VI

C

E S, IN

C

S J

EF

FE

R

SO

N S

T

ST

E

R

O A

N O

K E

VA

9/

/2

7 8 9 10

B

C

D

E

F

G

TM

J

W

2P M

R

UNCLASSIFIED//FOR OFFICIAL USE ONLY

UNCLASSIFIED//FOR OFFICIAL USE ONLY

W

2H N

-1 4-

D -0

READY TO ADVERTISE (RTA) SUBMISSION

A-601

PA

R

TI

TI

O N

T

YP

ES

R

BT

JB KB

FY

PN

8A

-6

.d w g

3" = 1'-0"A-601

1 CJ AT ACOUSTIC PTN

1 1/2" = 1'-0"A-601

DEVICE BACKBOX

@ ACOUSTIC PTN

M

AR

K

DE

SC

RI

PT

IO

N

DA

TE

AM

EN

DM

EN

T

1/

/2

A. REFER TO SHEET G-004 FOR ABBREVIATIONS.

B. REFER TO SHEET A-001 FOR GENERAL NOTES, LEGENDS

AND SYMBOLS.

C. REFER TO ARCHITECTURAL ENLARGED PLANS FOR DOOR

TAG LOCATIONS.

D. COORDINATE REQUIRED FIRE RATED DOORS WITH FIRE

RATED PARTITIONS, REFER TO LIFE SAFETY PLAN.

E. REFER TO SHEET A-622, A-623, A-625 AND A-640 FOR

HOLLOW METAL WINDOW AND CURTAINWALL FRAME

TYPES. SEE SPECIFICATION SECTION 08 44 00 FOR

CURTAINWALL REQUIREMENTS.

F. FRAME DEPTH FOR WRAP-AROUND HOLLOW METAL

FRAMES SHALL BE THE WIDTH OF THE PARTITION PLUS

1-1/8" OR AS NOTED. SEE PARTITION TYPES, SHEET A-601.

G. FIELD VERIFY OPENINGS PRIOR TO FABRICATION OF

ALUMINUM ENTRANCE SYSTEMS.

H. VIEW WINDOWS IN RATED DOORS ARE TO BE 100 SQ.

INCHES MAX.

I. SEE SPECIFICATIONS FOR DOOR HARDWARE SETS. REVIEW

ALL HARDWARE SETS AND LOCK FUNCTIONS WITH OWNER

PRIOR TO DEVELOPING FINAL HARDWARE SETS.

J. REFER TO ELECTRICAL AND TELECOM DRAWINGS FOR

POWER AND/OR CARD READER ACCESS REQUIREMENTS.

K. DOORS LOCATED NEAR PERPENDICULAR WALLS ARE TO BE

SET WITH FRAME 4" FROM FACE OF PERPENDICULAR WALL.

L. SEE SPECIFICATION 08 44 00 FOR ASTM CURTAINWALL

SYSTEM REQUIREMENTS.

GENERAL NOTES THIS SHEET:

H

W

H

W W W W

6" 6"

H

H

W

H

W

A B C

E - BID OPTION OVHD COILING

GL AS

SCHED

H

W W

D

GL AS

SCHED

ARMORY

H

W

F

GL AS

SCHED

2' -0

3'

-6

5"

3' -6

2'

-9

2'-8"

2" H

2" W 2"

2" H

2" W W 2"

4" H

2" W 2"

4" H

4" W 4"

F1 F2 F3

F4 - BID OPTION

2" H

2" W W 2"

2' -0

2"

F2A

GLASS AS

SCHED

2" H

2" W 2"

F5

STEEL

CHANNEL

FRAME

2" H

2" W 2"

F1A

GLASS AS

SCHED

2' -0

2"

ARMORY

2" H

2" W 2"

F6

STEEL CHANNEL

FRAME

SEE STRL DWGS

FOR OVHD DOOR

HOOD SUPPORT

SEE DETAIL 17/A-610

FOR TRANSOM DETAIL

GL-1 - LAMINATED STC-50 SOUND RATED GLASS

GL-2 - FIRE RATED GLAZING

GL-3 - TINTED INSULATED GLASS (LAMINATED)

GL-4 - TINTED INSULATING GLASS (LAMINATED) WITH FROSTED FILM

GL-5 - 1/4" THICK CLEAR TEMP GLASS

GL-6 - SPANDREL GLASS

GL-7 - 1/2" THICK CLEAR LAMINATED GLASS WITH FROSTED FILM

GL-8 - 1/2" THICK TINTED LAMINATED GLASS

GLASS SCHEDULE / TYPES

GENERAL NOTE - GLAZING

FOR GLAZING IN EXTERIOR BUILDING ELEMENTS, DOORS,

WINDOWS, CURTAIN WALLS, AND CLERESTORIES, PROVIDE NO

LESS THAN 1/4" (6MM) NOMINAL POLYCARBONATE OR

LAMINATED GLASS. THE 1/4" (6MM) LAMINATED GLASS CONSISTS

OF TWO NOMINAL 1/8" (3MM) GLASS PANES BONDED TOGETHER

WITH A MINIMUM OF A 0.030" (0.75MM) INTERLAYER OF A

MATERIAL DESIGNED FOR BLAST RESISTANCE IAW UFC 4-010-01,

STANDARD 10. REFER TO SPEC SECTION 08 81 00 GLAZING FOR

MORE INFORMATION.

4' 2' 0 4' 8' 1/4"=1'-0"

US Army Corps of Engineers ® Wilmington District

SHEET ID

U S

AR

M

Y C

O R

P S

O F

EN

G

IN

E

ER

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

C

AT

EG

O

R Y

C O

D E:

1 2 3 4 5

A

GRAPHIC SCALES

FO

R

T

BR

AG

G

, N O

R

TH

C

AR

O

LI

N A

SO

F

O

PE

R

AT

IO

N

S

FA

C

IL

IT

Y

FY

0, P

N

W

IL

M

IN

G

TO

N D

IS

TR

IC

T

W

IL

M

IN

G

TO

N , N

O R

TH

C

A R

O

LI

N A

AE

C

O M

S

ER

VI

C

E S, IN

C

S J

EF

FE

R

SO

N S

T

ST

E

R

O A

N O

K E

VA

9/

/2

7 8 9 10

B

C

D

E

F

G

TM

J

W

2P M

R

UNCLASSIFIED//FOR OFFICIAL USE ONLY

UNCLASSIFIED//FOR OFFICIAL USE ONLY

W

2H N

-1 4-

D -0

READY TO ADVERTISE (RTA) SUBMISSION

A-603

D O

O R

S C

H

ED

U

LE

D

O O

R T

YP

ES

D es ig ne r

Au th or

C he ck er

FY

PN

8A

-6

.d w g

DOOR SCHEDULE

DOOR

NO.

DOOR

TYPE

DOOR INFORMATION FRAME INFORMATION

HW

SET

SECURITY

DOOR

DETAIL COMMENTS:

SIZE DOOR

MATL

DOOR

FINISH

UNDER

CUT

Glass Type

FIRE

RATING

FRAME

TYPE

FRAME

MATL

FRAME

FINISH

DETAILS

WIDTH HEIGHT HEAD JAMB SILL

10 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F1 HM PAINT 3 / A-610 4 / A-610 INT-08

10A A 3' - 0" 7' - 0" HM PAINT - - - F1 HM PAINT 7 / A-610 8 / A-610 EXT-03A

11A B 6' - 0" 7' - 0" HM PAINT - - - F1 HM PAINT 7 / A-610 8 / A-610 EXT-06

11B A 4' - 0" 8' - 0" HM PAINT - - 45 MIN F2 HM PAINT 3 / A-610 4 / A-610 INT-07A

12 A 4' - 0" 7' - 0" HM PAINT - - - F3 HM PAINT 11 / A-610 12 / A-610 INT-13

13 A 4' - 0" 7' - 0" HM PAINT - - - F1 HM PAINT 5 / A-610 6 / A-610 INT-06 STC-45

14 A 3' - 0" 7' - 0" HM PAINT 3/4" - - F1 HM PAINT 3 / A-610 4 / A-610 INT-14

15 A 3' - 0" 7' - 0" HM PAINT 3/4" - - F1 HM PAINT 3 / A-610 4 / A-610 INT-15

15A A 3' - 0" 7' - 0" HM PAINT - - - F1 HM PAINT 3 / A-610 4 / A-610 INT-15

15AA A 3' - 0" 7' - 0" HM PAINT - - 45 MIN F1 HM PAINT 3 / A-610 4 / A-610 INT-16

15B A 3' - 0" 7' - 0" HM PAINT 3/4" - - F1 HM PAINT 3 / A-610 4 / A-610 INT-17

30 A 3' - 0" 7' - 0" HM PAINT - - - F3 HM PAINT 7 / A-610 8 / A-610 EXT-05 POL STOR BLDG 30A OVHD 6' - 6" 8' - 0" STL PREFIN - - - F5 STL PAINT 3 / A-611 4 / A-611 EXT-04 ELECTRIC OPERATION, POL STOR BLDG 100 C 6' - 0" 8' - 0" GLASS PREFIN - GL-7 - F2 ALUM PREFIN 15 / A-610 16 / A-610 INT-01 INTERIOR FULL GLASS 100A C 6' - 0" 8' - 0" GLASS PREFIN - GL-8 - F2 ALUM PREFIN 15 / A-610 16 / A-610 EXT-01 EXTERIOR FULL GLASS 100B D 6' - 0" 7' - 0" HM PAINT - GL-2 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-20

100C A 3' - 0" 7' - 0" HM PAINT - - - F1 HM PAINT 13 / A-610 14 / A-610 EXT-03

100D OVHD 16' - 0" 13' - 0" STL PREFIN - - - F6 STL PAINT 1 / A-611 2 / A-611 EXT-04 ELECTRIC OPERATION, INSULATED 100E OVHD 16' - 0" 13' - 0" STL PREFIN - - - F6 STL PAINT 1 / A-611 2 / A-611 EXT-04 ELECTRIC OPERATION, INSULATED

100F A 3' - 0" 7' - 0" HM PAINT - - - F1 HM PAINT 13 / A-610 14 / A-610 EXT-03

100K D 6' - 0" 7' - 0" HM PAINT - GL-2 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-20

102 B 6' - 0" 7' - 0" HM PAINT - - - F2 HM PAINT 3 / A-610 4 / A-610 INT-04

102A A 4' - 0" 7' - 0" HM PAINT - - - F1A HM PAINT 3 / A-610 4 / A-610 INT-03

103A A 3' - 0" 7' - 0" WD PREFIN STAIN - - - F1 HM PAINT 5 / A-610 6 / A-610 INT-06A STC-50 103B A 3' - 0" 7' - 0" WD PREFIN STAIN - - - F1 HM PAINT 5 / A-610 6 / A-610 INT-06A STC-50 104 A 4' - 0" 7' - 0" HM PAINT - - 45 MIN F1 HM PAINT 3 / A-610 4 / A-610 INT-09 STC-50 105 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-05 106 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-05 107 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-23 108 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-05 109A1 OVHD 10' - 0" 11' - 6" STL PREFIN - - 45 MIN F6 STL PAINT 5 / A-611 6 / A-611 INT-24 ELECTRIC OPERATION, FIRE RATED 109A2 F 4' - 0" 7' - 0" HM PAINT - GL-2 45 MIN F1A HM PAINT 3 / A-610 4 / A-610 INT-29 109B1 OVHD 10' - 0" 11' - 6" STL PREFIN - - 45 MIN F6 STL PAINT 5 / A-611 6 / A-611 INT-24 ELECTRIC OPERATION, FIRE RATED 109B2 F 4' - 0" 7' - 0" HM PAINT - GL-2 45 MIN F1A HM PAINT 3 / A-610 4 / A-610 INT-29 109C1 OVHD 10' - 0" 11' - 6" STL PREFIN - - 45 MIN F6 STL PAINT 5 / A-611 6 / A-611 INT-24 ELECTRIC OPERATION, FIRE RATED 109C2 F 4' - 0" 7' - 0" HM PAINT - GL-2 45 MIN F1A HM PAINT 3 / A-610 4 / A-610 INT-29 109D F 4' - 0" 7' - 0" HM PAINT - GL-2 45 MIN F1A HM PAINT 3 / A-610 4 / A-610 INT-05

110 B 6' - 0" 7' - 0" HM PAINT - - - F2 HM PAINT 3 / A-610 4 / A-610 INT-04

110A A 4' - 0" 7' - 0" HM PAINT - - - F1A HM PAINT 3 / A-610 4 / A-610 INT-03

S1B A 3' - 0" 7' - 0" HM PAINT - - - F3 HM PAINT 7 / A-610 8 / A-610 EXT-03

S3B A 3' - 0" 7' - 0" HM PAINT - - - F3 HM PAINT 9 / A-610 10 / A-610 EXT-03

S3C A 3' - 0" 6' - 6" HM PAINT - - 45 MIN F1 HM PAINT 9 / A-610 10 / A-610 EXT-07

20 A 4' - 0" 7' - 0" HM PAINT - - 45 MIN F1 HM PAINT 3 / A-610 4 / A-610 INT-18

20A A 3' - 0" 7' - 0" HM PAINT - - - F1 HM PAINT 3 / A-610 4 / A-610 INT-11

21 A 3' - 0" 7' - 0" HM PAINT 3/4" - - F1 HM PAINT 3 / A-610 4 / A-610 INT-14

22 A 3' - 0" 7' - 0" HM PAINT - - - F1 HM PAINT 3 / A-610 4 / A-610 INT-15

23 A 3' - 0" 7' - 0" HM PAINT 3/4" - - F1 HM PAINT 3 / A-610 4 / A-610 INT-17

24 A 4' - 0" 7' - 0" HM PAINT - - 45 MIN F1 HM PAINT 5 / A-610 6 / A-610 INT-06 STC-45

25 A 3' - 0" 7' - 0" HM PAINT - - 45 MIN F1 HM PAINT 3 / A-610 4 / A-610 INT-19

201 A 4' - 0" 7' - 0" WD PREFIN STAIN - - 45 MIN F1 HM PAINT 5 / A-610 6 / A-610 INT-06 STC-50 201A A 3' - 6" 7' - 0" WD PREFIN STAIN - - - F1 HM PAINT 5 / A-610 6 / A-610 INT-12 STC-45 201B A 3' - 6" 7' - 0" WD PREFIN STAIN - - - F1 HM PAINT 5 / A-610 6 / A-610 INT-09A STC-45 201BA A 3' - 6" 7' - 0" WD PREFIN STAIN - - - F1 HM PAINT 5 / A-610 6 / A-610 INT-26 STC-45 201C A 3' - 6" 7' - 0" WD PREFIN STAIN - - - F1 HM PAINT 5 / A-610 6 / A-610 INT-09 STC-50 201D A 4' - 0" 7' - 0" WD PREFIN STAIN - - - F1 HM PAINT 5 / A-610 6 / A-610 INT-09 STC-45 201DA A 3' - 0" 7' - 0" WD PREFIN STAIN - - 45 MIN F1 HM PAINT 5 / A-610 6 / A-610 INT-10 STC-50 201E A 3' - 0" 7' - 0" WD PREFIN STAIN - - - F1 HM PAINT 1 / A-610 2 / A-610 INT-02 201F A 3' - 0" 7' - 0" WD PREFIN STAIN - - - F1 HM PAINT 1 / A-610 2 / A-610 INT-17 201G A 3' - 6" 7' - 0" WD PREFIN STAIN - - - F1 HM PAINT 3 / A-610 4 / A-610 INT-03 201GA A 3' - 6" 7' - 0" WD PREFIN STAIN - - - F1 HM PAINT 3 / A-610 4 / A-610 INT-26 201H A 3' - 0" 7' - 0" WD PREFIN STAIN 3/4" - - F1 HM PAINT 1 / A-610 2 / A-610 INT-17 202 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-05 203 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-05 204 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-05

205 A 3' - 0" 7' - 0" HM PAINT - - 45 MIN F1 HM PAINT 3 / A-610 4 / A-610 INT-07

205A B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2 HM PAINT 3 / A-610 4 / A-610 INT-05

206 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2 HM PAINT 3 / A-610 4 / A-610 INT-05

207 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-05 208 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-05 209 B 6' - 0" 7' - 0" HM PAINT - - 45 MIN F2A HM PAINT 3 / A-610 4 / A-610 INT-05

209A B 6' - 0" 7' - 0" HM PAINT - - - F2 HM PAINT 3 / A-610 4 / A-610 INT-28

S1A A 3' - 0" 7' - 0" HM PAINT - - 60 MIN F3 HM PAINT 11 / A-610 12 / A-610 INT-27 S3A A 3' - 0" 7' - 0" HM PAINT - - 60 MIN F3 HM PAINT 11 / A-610 12 / A-610 INT-27

1/4" = 1'-0"

DOOR TYPES

1/4" = 1'-0"

FRAME TYPES

DOOR SCHEDULE - BID OPTION

DOOR

NO.

DOOR

TYPE

DOOR INFORMATION FRAME INFORMATION

HW

SET

SECURITY

DOOR

DETAIL COMMENTS:

SIZE DOOR

MATL

DOOR

FINISH

UNDER

CUT

Glass Type

FIRE

RATING

FRAME

TYPE

FRAME

MATL

FRAME

FINISH

DETAILS

WIDTH HEIGHT HEAD JAMB SILL

111 E 4' - 0" 7' - 0" HM PAINT - - 45 MIN F4 STL PAINT 7/A-611 8/A-611 - EXT-02 CLASS 5A ARMORY DOOR AND

DUTCH-STYLE DAY GATE

M

AR

K

DE

SC

RI

PT

IO

N

DA

TE

AM

EN

DM

EN

T

1/

/2

4 7/8"

PTN WITH 3-5/8"

FRAMING

INSUL AS REQD PER

PTN TYPE INDICATED

HM FRAME AS

SCHED, PNT

DOOR AS SCHED

CONT SNT,

BOTH SIDES 4

7/ 8"

PTN WITH 3-5/8"

FRAMING

INSUL AS REQD PER

PTN TYPE INDICATED

HM FRAME AS

SCHED, PNT,3 AHRS

PER JAMB MIN

DOOR AS SCHED

CONT SNT,

BOTH SIDES

7 1/4"

PTN WITH 6"

FRAMING

INSUL AS REQD PER

PTN TYPE INDICATED

HM FRAME AS

SCHED, PNT

DOOR AS SCHED

CONT SNT,

BOTH SIDES

1/

4"

PTN WITH 6"

FRAMING

INSUL AS REQD PER

PTN TYPE INDICATED

HM FRAME AS

SCHED, PNT, 3 AHRS

PER JAMB, MIN

DOOR AS SCHED

CONT SNT,

BOTH SIDES

8 1/2"

PTN WITH 6"

FRAMING AND DBL

LAYER GWB

INSUL AS REQD PER

PTN TYPE INDICATED

HM FRAME AS

SCHED, PNT

DOOR AS SCHED

CONT SNT,

BOTH SIDES

1/

2"

PTN WITH 6"

FRAMING

INSUL AS REQD PER

PTN TYPE INDICATED

HM FRAME AS

SCHED, PNT, 3 AHRS

PER JAMB MIN

DOOR AS SCHED

CONT SNT,

BOTH SIDES

5 3/4"

SEE PLAN

VARIES

8" CMU

1"

MET STUD OR

FURRING AND

GWB PER PLAN

CONT SNT,

BOTH SIDES

HM FRAME, PNT

DOOR AS

SCHED

3/

4"

SE

E

PL

AN

VA

R

IE

S

DOOR AS SCHED

HM FRAME, PNT

CONT SNT,

BOTH SIDES

8" CMU

MET STUD OR

FURRING AND

GWB PER PLAN

FR AHR

1"

7 1/2" 5 3/4"

DOOR AS SCHED

HM FRAME, GROUT FULL

CMU LINTEL, SEE

STRL DWGS

REINF CMU

CONT SNT & BACKER

ROD BOTH SIDES

STL LINTEL, PAINTED,

SEE STRL DWGS

CONT METAL

FLASHING W/ WEEPS

GROUND FACE

(BURNISHED CMU)

RIGID INSULATION

CONT AIR BARRIER

3/

4"

1/ 2"

PREFABRICATED

GROUND FACE

(BURNISHED) CMU

CORNER UNIT

RIGID INSULATION

CONT AIR BARRIER, TYP

8" REINF CMU

ANCHOR MIN 3 PER JAMB

BULLNOSE, TYP

CONT SNT &

BACKER ROD

BOTH SIDES

DOOR AS

SCHED

HM FRAME

GROUT FULL

5 3/4"

2 1/2"

PREFIN INSUL

MET WALL PNL

MTL WALL

PANEL TRIM

CONT MTL

FLASHING W/ DRIP

CONT SNT &

BACKER ROD

BOTH SIDES

REINF CMU

CMU LINTEL,

SEE STRL DWGS

HM FRAME,

GROUT FULL

DOOR AS SCHED

CONT AIR

BARRIER

3/

4"

MET WALL

PANEL TRIM

PREFIN INSULATED

MET WALL PANEL

CONT AIR BARRIER, TYP

8" REINF CMU

ANCHOR MIN 3 PER JAMB

BULLNOSE, TYP

CONT SNT &

BACKER ROD

BOTH SIDES

DOOR AS

SCHED

HM FRAME

GROUT FULL

1/

2"

8 1/4"

2 3/4"

PREFIN INSUL

MET WALL PNL

MTL WALL

PANEL TRIM

CONT MTL

FLASHING W/ DRIP

CONT SNT &

BACKER ROD

BOTH SIDES

HM FRAME,

GROUT FULL

CONT SNT, ALL

SIDES

MTL STUD

HEADER

2 1/2" THK

SOUND BATTS

5/8" GWB ON 6"

MTL STUDS

1/2" GLASS MAT

SHEATHING

CONT AIR

BARRIER

1/

4"

PREFIN INSUL

MET WALL PNL

MTL WALL

PANEL TRIM

ANCHORS, MIN 3

PER JAMB

HM FRAME,

GROUT FULL

CONT SNT, ALL

SIDES DOUBLE STUDS

@ JAMBS

2 1/2" THK

SOUND BATTS

5/8" GWB ON 6"

MTL STUDS

1/2" GLASS MAT

SHEATHING

CONT AIR

BARRIER

CONT SNT &

BACKER ROD

BOTH SIDES

ALUM DOOR

GLASS AS SCHED

PREFIN MET

CURTAINWALL SYSTEM

1/8"3 1/2"

6"

2 1/2"

DOOR STOP

1/ 8"

1/

2"

6"

1/

2"

PREFIN MET

CURTAINWALL SYSTEM

DOOR STOP

ALUM. DOOR

GLASS AS SCHED

HM FRAME AS

SCHED, PNT

DOOR AS SCHED

REMOVABLE

STOP

GL AS

SCHED

2"

12" 9" 6" 3" 0 3"=1'-0"

12" 9" 6" 3" 0 1' 1-1/2"=1'-0"

US Army Corps of Engineers ® Wilmington District

SHEET ID

U S

AR

M

Y C

O R

P S

O F

EN

G

IN

E

ER

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

C

AT

EG

O

R Y

C O

D E:

1 2 3 4 5

A

GRAPHIC SCALES

FO

R

T

BR

AG

G

, N O

R

TH

C

AR

O

LI

N A

SO

F

O

PE

R

AT

IO

N

S

FA

C

IL

IT

Y

FY

0, P

N

W

IL

M

IN

G

TO

N D

IS

TR

IC

T

W

IL

M

IN

G

TO

N , N

O R

TH

C

A R

O

LI

N A

AE

C

O M

S

ER

VI

C

E S, IN

C

S J

EF

FE

R

SO

N S

T

ST

E

R

O A

N O

K E

VA

9/

/2

7 8 9 10

B

C

D

E

F

G

TM

J

W

2P M

R

UNCLASSIFIED//FOR OFFICIAL USE ONLY

UNCLASSIFIED//FOR OFFICIAL USE ONLY

W

2H N

-1 4-

D -0

READY TO ADVERTISE (RTA) SUBMISSION

A-610

D O

O R

D

ET

AI

LS

D es ig ne r

Au th or

C he ck er

FY

PN

8A

-6

.d w g

1 1/2" = 1'-0"A-610

1 HEAD DETAIL - 3-5/8" STUD

1 1/2" = 1'-0"A-610

2 JAMB DETAIL - 3-5/8" STUD

1 1/2" = 1'-0"A-610

3 HEAD DETAIL - 6" STUD

1 1/2" = 1'-0"A-610

4 JAMB DETAIL - 6" STUD

1 1/2" = 1'-0"A-610

5 HEAD DETAIL - 6" STUD DBL GWB

1 1/2" = 1'-0"A-610

6 JAMB DETAIL - 6" STUD DBL GWB

1 1/2" = 1'-0"A-610

11 HEAD DETAIL - CMU

1 1/2" = 1'-0"A-610

12 JAMB DETAIL - CMU

1 1/2" = 1'-0"A-610

7 HEAD DETAIL - CMU

1 1/2" = 1'-0"A-610

8 JAMB DETAIL - CMU

1 1/2" = 1'-0"A-610

9 HEAD DETAIL - CMU / MET PANEL

1 1/2" = 1'-0"A-610

10 JAMB DETAIL - CMU / MET PANEL

1 1/2" = 1'-0"A-610

13 HEAD DETAIL - MET PANEL

1 1/2" = 1'-0"A-610

14 JAMB DETAIL - MET PANEL

3" = 1'-0"A-610

16 JAMB DETAIL - CURTAINWALL

3" = 1'-0"A-610

15 HEAD DETAIL- CURTAINWALL

NOTE: SEE AIR BARRIER DETAILS ON SHEET

A-805 FOR DETAILS AT ROUGH OPENINGS

M

AR

K

DE

SC

RI

PT

IO

N

DA

TE

AM

EN

DM

EN

T

1/

/2

1 1/2" = 1'-0"A-610

17 HEAD DETAIL - HM TRANSOM

OCCURS AT FRAME

TYPES F1A AND F2A,

SEE SHEET A-603

FIRST FLOOR

EL 0"

GL-5

6'-10"

6' -6

3'

-6

'-0

2" 6'

-2

2"

2" 6'-6" 2"

FIRST FLOOR

EL 0"

GL-5

9'-6"

2" 5'

-6

2"

5' -1

0" 3'

-6

2" EQ 4'-0" EQ 2"

GL-5GL-5

FIRST FLOOR

EL 0"

GL-5 GL-5GL-5

2" EQ 4'-0" 4'-0" EQ 2"

19'-6"

2" 5'

-6

2"

5' -1

0" 3'

-6

9' -4

GL-5 GL-5GL-5

2" EQ EQ 2" 2'-0"

FIRST FLOOR

EL 0"

GL-5

10'-6"

2" 3'-1" 4'-0" 3'-1" 2"

2" 5'

-6

2"

5' -1

0" 3'

-6

9' -4

GL-5 GL-5

FIRST FLOOR

EL 0"

8'-0"

2" 1'-10" 4'-0" 1'-10" 2"

3' -6

5'

-1 0"

2" 5'

-6

2"

9' -4

GL-5 GL-5 GL-5

FIRST FLOOR

EL 0"

2" 5'

-6

2"

5' -1

0" 3'

-6

9' -4

6'-0" 2" 5'-8" 2"

GL-5

FIRST FLOOR

EL 0"

10'-0"

2" 2'-10" 4'-0" 2'-10" 2"

9' -4

3' -6

5'

-1 0"

2" 5'

-6

2"

GL-5 GL-5 GL-5

FIRST FLOOR

EL 0"

GL-1GL-1 GL-1

32'-0"

2" 7'

-0

2"

1' -8

7'

-4

GL-1 GL-1 GL-1 GL-1

A-621

4 HEAD &

JAMB SIM

4'-6"2"4'-6"2" 2" 4'-6" 2" 4'-6" 2" 4'-6" 2"4'-1"2" 2" 4'-1" 2"

SECOND FLOOR

EL 18'-0"

2" 4'-5" 2"

4'-9"

2" 5'

-6

2"

3' -6

5'

-1 0"

9' -4

GL-5

SECOND FLOOR

EL 18'-0"

2" 5'-2" 2"

5'-6"

2" 5'

-6

2"

5' -1

0" 3'

-6

9' -4

GL-5

SECOND FLOOR

EL 18'-0"

GL-5

2" EQ 4'-0" 4'-0" 4'-0" EQ 2"

GL-5 GL-5GL-5

27'-6 5/8"

2" 5'

-6

2"

5' -1

0" 3'

-6

9' -4

GL-5 GL-5 GL-5

2" EQ 4'-0" EQ 2" 2'-0"

GL-5

SECOND FLOOR

EL 18'-0"

GL-5

16'-11 3/8"

GL-5 GL-5

2" 4'-3 3/4" 8'-0" 4'-3 3/4" 2"

2" 5'

-6

2"

5' -1

0" 3'

-6

9' -4

SECOND FLOOR

EL 18'-0"

GL-5

12'-1" 2" 11'-9" 2"

2" 5'

-6

2"

5' -1

0" 3'

-6

9' -4

GL-5 GL-5

GL-1 - LAMINATED STC-50 SOUND RATED GLASS

GL-2 - FIRE RATED GLAZING

GL-3 - TINTED INSULATED GLASS (LAMINATED)

GL-4 - TINTED INSULATING GLASS (LAMINATED) WITH FROSTED FILM

GL-5 - 1/4" THICK CLEAR TEMP GLASS

GL-6 - SPANDREL GLASS

GL-7 - 1/2" THICK CLEAR LAMINATED GLASS WITH FROSTED FILM

GL-8 - 1/2" THICK TINTED LAMINATED GLASS

GLASS SCHEDULE / TYPES

GENERAL NOTE - GLAZING

FOR GLAZING IN EXTERIOR BUILDING ELEMENTS, DOORS,

WINDOWS, CURTAIN WALLS, AND CLERESTORIES, PROVIDE NO

LESS THAN 1/4" (6MM) NOMINAL POLYCARBONATE OR

LAMINATED GLASS. THE 1/4" (6MM) LAMINATED GLASS CONSISTS

OF TWO NOMINAL 1/8" (3MM) GLASS PANES BONDED TOGETHER

WITH A MINIMUM OF A 0.030" (0.75MM) INTERLAYER OF A

MATERIAL DESIGNED FOR BLAST RESISTANCE IAW UFC 4-010-01,

STANDARD 10. REFER TO SPEC SECTION 08 81 00 GLAZING FOR

MORE INFORMATION.

SECOND FLOOR

EL 18'-0"

14'-3"

2" EQ 4'-0" 4'-0" EQ 2"

3' -6

5'

-1 0"

2" 5'

-6

2"

9' -4

GL-5 GL-5 GL-5 GL-5

4' 2' 0 4' 8' 1/4"=1'-0"

US Army Corps of Engineers ® Wilmington District

SHEET ID

U S

AR

M

Y C

O R

P S

O F

EN

G

IN

E

ER

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

C

AT

EG

O

R Y

C O

D E:

1 2 3 4 5

A

GRAPHIC SCALES

FO

R

T

BR

AG

G

, N O

R

TH

C

AR

O

LI

N A

SO

F

O

PE

R

AT

IO

N

S

FA

C

IL

IT

Y

FY

0, P

N

W

IL

M

IN

G

TO

N D

IS

TR

IC

T

W

IL

M

IN

G

TO

N , N

O R

TH

C

A R

O

LI

N A

AE

C

O M

S

ER

VI

C

E S, IN

C

S J

EF

FE

R

SO

N S

T

ST

E

R

O A

N O

K E

VA

9/

/2

7 8 9 10

B

C

D

E

F

G

TM

J

W

2P M

R

UNCLASSIFIED//FOR OFFICIAL USE ONLY

UNCLASSIFIED//FOR OFFICIAL USE ONLY

W

2H N

-1 4-

D -0

READY TO ADVERTISE (RTA) SUBMISSION

A-625

IN

TE

R

IO

R W

IN

D

O W

E

LE

VA

TI

O N

S

D es ig ne r

Au th or

C he ck er

FY

PN

8A

-6

.d w g

W20

W21

W22

W23

W24

W25

W26

W27

W28

W30

W32

W33

W31

W29

M

AR

K

DE

SC

RI

PT

IO

N

DA

TE

AM

EN

DM

EN

T

1/

/2

1 1

1 1

ALL INTERIOR WINDOW FRAMES ARE HOLLOW METAL.

SEE DETAILS 1,2,3 & 4 ON SHEET A-621.

US Army Corps of Engineers ® Wilmington District

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

C A

T E

G O

R Y

C O

D E

1 2 3 4 5

A

F O

R T

B R

A G

G N

O R

T H

C A

R O

L

IN

A S

O F

O P

E R

A T

IO

N

S F

A C

IL

IT

Y F

Y

P

N

W

IL

M

IN

G T

O N

D

IS

T

R

IC

T W

IL

M

IN

G

T O

N N

O R

T H

C A

R O

L

IN

A

A E

C O

M S

E R

V

IC

E S

IN

C

S

J E

F F

E R

S O

N S

T S

T E

R O

A N

O K

E V

A

/2

/2

7 8 9 10

B

C

D

E

F

G

T M

J

W P

M R

UNCLASSIFIED//FOR OFFICIAL USE ONLY

UNCLASSIFIED//FOR OFFICIAL USE ONLY

W H

N -1

-D

-0

READY TO ADVERTISE (RTA) SUBMISSION

G-003

IN

D

E X

O F

D R

A W

IN

G

S

D e s ig n e r

A u th o r

C h e c k e r

F Y

P

N G

-0 .d w g

INDEX OF DRAWINGS - VOLUME II

SHEET ID FILENAME SHEET TITLE

EL702A FY20PN88658EL702A.dwg SECOND FLOOR NORMAL LIGHTING PLAN POINT BY POINT - AREA A

EL702B FY20PN88658EL702B.dwg SECOND FLOOR NORMAL LIGHTING PLAN POINT BY POINT - AREA B

EL703 FY20PN88658EL703.dwg LIGHTING FIXTURE SCHEDULE

EL711A FY20PN88658EL711A.dwg FIRST FLOOR EMERGENCY LIGHTING PLAN POINT BY POINT -

AREA A

EL711B FY20PN88658EL711B.dwg FIRST FLOOR EMERGENCY LIGHTING PLAN POINT BY POINT -

AREA B

EL712A FY20PN88658EL712A.dwg SECOND FLOOR EMERGENCY LIGHTING PLAN POINT BY POINT -

AREA A

EL712B FY20PN88658EL712B.dwg SECOND FLOOR EMERGENCY LIGHTING PLAN POINT BY POINT -

AREA B

EP101A FY20PN88658EP101A.dwg FIRST FLOOR POWER PLAN - AREA A

EP101B FY20PN88658EP101B.dwg FIRST FLOOR POWER PLAN - AREA B

EP102A FY20PN88658EP102A.dwg SECOND FLOOR POWER PLAN - AREA A

EP102B FY20PN88658EP102B.dwg SECOND FLOOR POWER PLAN - AREA B

EP401 FY20PN88658EP401.dwg ENLARGED POWER PLANS

EP402 FY20PN88658EP402.dwg ENLARGED POWER PLANS

EP403 FY20PN88658EP403.dwg ENLARGED POWER PLANS

ES101 FY20PN88658ES101.dwg ELECTRICAL SITE PLAN

EM101A FY20PN88658EM101A.dwg FIRST FLOOR ELECTRICAL MECHANICAL PLAN - AREA A

EM101B FY20PN88658EM101B.dwg FIRST FLOOR ELECTRICAL MECHANICAL PLAN - AREA B

EM102A FY20PN88658EM102A.dwg SECOND FLOOR ELECTRICAL MECHANICAL PLAN - AREA A

EM102B FY20PN88658EM102B.dwg SECOND FLOOR ELECTRICAL MECHANICAL PLAN - AREA B

EM103A FY20PN88658EM103A.dwg ROOF ELECTRICAL MECHANICAL PLAN - AREA A

EM103B FY20PN88658EM103B.dwg ROOF ELECTRICAL MECHANICAL PLAN - AREA B

E-501 FY20PN88658E-501.dwg ELECTRICAL DETAILS

E-502 FY20PN88658E-502.dwg ELECTRICAL DETAILS

E-503 FY20PN88658E-503.dwg ELECTRICAL DETAILS

E-601 FY20PN88658E-601.dwg ONE-LINE DIAGRAM

E-701 FY20PN88658E-701.dwg ELECTRICAL GENERAL SCHEDULES

E-702 FY20PN88658E-702.dwg ELECTRICAL PANEL SCHEDULES

E-703 FY20PN88658E-703.dwg ELECTRICAL PANEL SCHEDULES

E-704 FY20PN88658E-704.dwg ELECTRICAL PANEL SCHEDULES

E-705 FY20PN88658E-705.dwg ELECTRICAL PANEL SCHEDULES

E-706 FY20PN88658E-706.dwg ELECTRICAL PANEL SCHEDULES

E-707 FY20PN88658E-707.dwg ELECTRICAL PANEL SCHEDULES

E-708 FY20PN88658E-708.dwg ELECTRICAL PANEL SCHEDULES

E-709 FY20PN88658E-709.dwg ELECTRICAL PANEL SCHEDULES

E-710 FY20PN88658E-710dwg ELECTRICAL PANEL SCHEDULES

E-711 FY20PN88658E-711.dwg ELECTRICAL PANEL SCHEDULES

E-712 FY20PN88658E-712.dwg ELECTRICAL PANEL SCHEDULES

E-713 FY20PN88658E-713.dwg ELECTRICAL PANEL SCHEDULES

E-714 FY20PN88658E-714.dwg ELECTRICAL PANEL SCHEDULES

AUDIOVISUAL

TA-001 FY20PN88658TA-001.dwg AUDIOVISUAL GENERAL NOTES, SYMBOLS & ABBREVIATIONS

TA-101A FY20PN88658TA-101A.dwg AUDIOVISUAL FIRST FLOOR PLAN - AREA A

TA-101B FY20PN88658TA-101B.dwg AUDIOVISUAL FIRST FLOOR PLAN - AREA B

TA-102A FY20PN88658TA-102A.dwg AUDIOVISUAL SECOND FLOOR PLAN - AREA A

TA-102B FY20PN88658TA-102B.dwg AUDIOVISUAL SECOND FLOOR PLAN - AREA B

TA-111A FY20PN88658TA-111A.dwg AUDIOVISUAL FIRST FLOOR RCP - AREA A

TA-111B FY20PN88658TA-111B.dwg AUDIOVISUAL FIRST FLOOR RCP - AREA B

TA-112A FY20PN88658TA-112A.dwg AUDIOVISUAL SECOND FLOOR RCP - AREA A

TA-112B FY20PN88658TA-111B.dwg AUDIOVISUAL SECOND FLOOR RCP - AREA B

TA-501 FY20PN88658TA-501.dwg AUDIOVISUAL ELEVATIONS

TA-502 FY20PN88658TA-502.dwg AUDIOVISUAL ELEVATIONS

TA-503 FY20PN88658TA-503.dwg AUDIOVISUAL ELEVATIONS

TA-504 FY20PN88658TA-504.dwg AUDIOVISUAL ELEVATIONS

TA-505 FY20PN88658TA-505.dwg AUDIOVISUAL ELEVATIONS

TA-506 FY20PN88658TA-506.dwg AUDIOVISUAL ELEVATIONS

TA-600 FY20PN88658TA-600.dwg AUDIOVISUAL SCHEDULES

TA-601 FY20PN88658TA-601.dwg AUDIOVISUAL RISER DIAGRAMS

TELECOMMUNICATIONS

T-001 FY20PN88658T-001.dwg TELECOMMUNICATIONS GENERAL NOTES, SYMBOLS &

ABBREVIATIONS

T-100 FY20PN88658T-100.dwg TELECOMMUNICATION SITE PLAN

T-101A FY20PN88658T-101A.dwg TELECOMMUNICATIONS FIRST FLOOR PLAN - AREA A

T-101B FY20PN88658T-101B.dwg TELECOMMUNICATIONS FIRST FLOOR PLAN - AREA B

T-102A FY20PN88658T-103B.dwg TELECOMMUNICATIONS SECOND FLOOR PLAN - AREA A

T-102B FY20PN88658T-102B.dwg TELECOMMUNICATIONS SECOND FLOOR PLAN - AREA B

T-103A FY20PN88658T-103A.dwg TELECOMMUNICATIONS ROOF PLAN - AREA A

T-103B FY20PN88658T-103B.dwg TELECOMMUNICATIONS ROOF PLAN - AREA B

T-111A FY20PN88658T-111A.dwg TELECOMMUNICATIONS FIRST FLOOR REFLECTED CEILING PLAN

- AREA A

T-111B FY20PN88658T-111B.dwg TELECOMMUNICATIONS FIRST FLOOR REFLECTED CEILING PLAN

- AREA B

T-112A FY20PN88658T-112A.dwg TELECOMMUNICATIONS SECOND FLOOR REFLECTED CEILING

PLAN - AREA A

T-112B FY20PN88658TA-112B.dwg TELECOMMUNICATIONS SECOND FLOOR REFLECTED CEILING

PLAN - AREA B

T-112C FY20PN88658T-112C.dwg TELECOMMUNICATIONS SECOND FLOOR SWA RAISED ACCESS

FLOOR PLAN - AREA A

T-401 FY20PN88658T-401.dwg TELECOMMUNICATION ENLARGED PLAN

T-402 FY20PN88658T-402.dwg TELECOMMUNICATION ENLARGED PLAN

T-403 FY20PN88658T-403.dwg TELECOMMUNICATION ENLARGED PLAN

T-404 FY20PN88658T-404.dwg TELECOMMUNICATION ENLARGED PLAN

T-501 FY20PN88658T-501.dwg TELECOMMUNICATION DETAILS

T-502 FY20PN88658T-502.dwg TELECOMMUNICATION DETAILS

T-503 FY20PN88658T-503.dwg TELECOMMUNICATION SCHEDULE

T-504 FY20PN88658T-504.dwg TELECOMMUNICATION SCHEDULE

T-601 FY20PN88658T-601.dwg TELECOMMNICATIONS ONE-LINE DIAGRAM

T-602 FY20PN88658T-602.dwg TELECOMMNUICATION ONE-LINE DIAGRAM

T-603 FY20PN88658T-603.dwg TELECOMUNICATIONS PDS

SECURITY

TY-001 FY20PN88658TY001.dwg SECURITY GENERAL NOTES, SYMBOLS & ABBREVIATIONS

TY-604 FY20PN88658TY604.dwg SECURITY DETAILS

TY-101A FY20PN88658TY10A.dwg SECURITY FIRST FLOOR PLAN - AREA A

TY-101B FY20PN88658T-101B.dwg SECURITY FIRST FLOOR PLAN - AREA B

TY-102A FY20PN88658TY102A.dwg SECURITY SECOND FLOOR PLAN - AREA A

TY-102B FY20PN88658TY102B.dwg SECURITY SECOND FLOOR PLAN - AREA B

TY-103B FY20PN88658T-103B.dwg SECURITY ROOF PLAN - AREA B

INDEX OF DRAWINGS - VOLUME II

SHEET ID FILENAME SHEET TITLE

FIRE ALARM

FA001 FY20PN88658FA001.dwg FIRE ALARM GENERAL NOTES AND LEGEND

FA101A FY20PN88658FA101A.dwg FIRST FLOOR FIRE ALARM FLOOR PLAN - AREA A

FA101B FY20PN88658FA101B.dwg FIRST FLOOR FIRE ALARM FLOOR PLAN - AREA B

FA101C FY20PN88658FA101C.dwg FIRST FLOOR FIRE ALARM FLOOR PLAN - AREA C

FA102A FY20PN88658FA102A.dwg SECOND FLOOR FIRE ALARM FLOOR PLAN - AREA A

FA102B FY20PN88658FA102B.dwg SECOND FLOOR FIRE ALARM FLOOR PLAN - AREA B

FA501 FY20PN88658FA501.dwg FIRE ALARM SEQUENCE OF OPERATIONS MATRIX

FA502 FY20PN88658FA502.dwg FIRE ALARM RISER DIAGRAM

FIRE SUPPRESSION

FX001 FY20PN88658FX001.dwg FIRE SUPPRESSION GENERAL NOTES

FX101A FY20PN88658FX101A.dwg FIRST FLOOR FIRE SUPPRESSION FLOOR PLAN - AREA A

FX101B FY20PN88658FX101B.dwg FIRST FLOOR FIRE SUPPRESSION FLOOR PLAN - AREA B

FX101C FY20PN88658FX101C.dwg FIRE FLOOR FIRE SUPPRESSION FLOOR PLAN - AREA C

FX102A FY20PN88658FX102A.dwg SECOND FLOOR FIRE SUPPRESSION FLOOR PLAN - AREA A

FX102B FY20PN88658FX102B.dwg SECOND FLOOR FIRE SUPPRESSION FLOOR PLAN - AREA B

FX401 FY20PN88658FX401.dwg FIRE SUPPRESSION CLEAN AGENT ENLARGED PLAN AND

SEQUENCE OF OPERATIONS MATRIX

FX501 FY20PN88658FX501.dwg FIRE SUPPRESSION DETAILS

FX502 FY20PN88658FX502.dwg FIRE SUPPRESSION DETAILS

PLUMBING

P-001 FY20PN88658P-001.dwg GENERAL NOTES AND LEGENDS

PU100A FY20PN88658PU100A.dwg UNDERGROUND DWV PLAN - AREA A

PU100B FY20PN88658PU100B.dwg UNDERGROUND DWV PLAN - AREA B

PW101A FY20PN88658PW101A.dwg FIRST FLOOR DWV PLAN - AREA A

PW101B FY20PN88658PW101B.dwg FIRST FLOOR DWV PLAN - AREA B

PW102A FY20PN88658PW102A.dwg SECOND FLOOR DWV PLAN - AREA A

PW102B FY20PN88658PW102B.dwg SECOND FLOOR DWV PLAN - AREA B

PW103A FY20PN88658PW103A.dwg ROOF PLAN - AREA A

PW103B FY20PN88658PW103B.dwg ROOF PLAN - AREA B

PL101A FY20PN88658PL101A.dwg FIRST FLOOR SUPPLY PLAN - AREA A

PL101B FY20PN88658PL101B.dwg FIRST FLOOR SUPPLY PLAN - AREA B

PL102A FY20PN88658PL102A.dwg SECOND FLOOR SUPPLY PLAN - AREA A

PL102B FY20PN88658PL102B.dwg SECOND FLOOR SUPPLY PLAN - AREA B

P-401 FY20PN88658P-401.dwg ENLARGED PLANS

P-501 FY20PN88658P-501.dwg DETAILS

P-502 FY20PN88658P-502.dwg DETAILS

P-503 FY20PN88658P-503.dwg DETAILS

P-504 FY20PN88658P-504.dwg DETAILS

P-601 FY20PN88658P-601.dwg SCHEDULES

P-701 FY20PN88658P-701.dwg RISER DIAGRAMS

P-702 FY20PN88658P-702.dwg RISER DIAGRAMS

MECHANICAL

M-001 FY20PN88658M-001.dwg MECHANICAL LEGEND AND GENERAL NOTES

MH101A FY20PN88658MH101A.dwg FIRST FLOOR DUCT PLAN - AREA A

MH101B FY20PN88658MH101B.dwg FIRST FLOOR DUCT PLAN - AREA B

MH102A FY20PN88658MH102A.dwg SECOND FLOOR DUCT PLAN - AREA A

MH102B FY20PN88658MH102B.dwg SECOND FLOOR DUCT PLAN - AREA B

MH103A FY20PN88658MH103A.dwg ROOF DUCT PLAN - AREA A

MH103B FY20PN88658MH103B.dwg ROOF DUCT PLAN - AREA B

MP101A FY20PN88658MP101A.dwg 1ST FLOOR PIPING PLAN - AREA A

MP101B FY20PN88658MP101B.dwg 1ST FLOOR PIPING PLAN - AREA B

MP102A FY20PN88658MP102A.dwg 2ND FLOOR PIPING PLAN - AREA A

MP102B FY20PN88658MP102B.dwg 2ND FLOOR PIPING PLAN - AREA B

MP103A FY20PN88658M103A.dwg ROOF PIPING PLAN - AREA A

MP103B FY20PN88658M103B.dwg ROOF PIPING PLAN - AREA B

M-301 FY20PN88658M-301.dwg SECTIONS

M-302 FY20PN88658M-302.dwg SECTIONS

M-401 FY20PN88658M-401.dwg ENLARGED FLOOR PLANS

M-402 FY20PN88658M-402.dwg ENLARGED FLOOR PLANS

M-501 FY20PN88658M-501.dwg MECHANICAL DETAILS

M-502 FY20PN88658M-502.dwg MECHANICAL DETAILS

M-503 FY20PN88658M-503.dwg MECHANICAL DETAILS

M-504 FY20PN88658M-504.dwg MECHANICAL DETAILS

M-505 FY20PN88658M-505.dwg MECHANICAL DETAILS

M-601 FY20PN88658M-601.dwg MECHANICAL SCHEDULES

M-602 FY20PN88658M-602.dwg MECHANICAL SCHEDULES

M-603 FY20PN88658M-603.dwg MECHANICAL SCHEDULES

M-604 FY20PN88658M-604.dwg MECHANICAL SCHEDULES

M-701 FY20PN88658M-701.dwg FLOW DIAGRAMS

M-702 FY20PN88658M-702.dwg FLOW DIAGRAMS

M-800 FY20PN88658M-800.dwg CONTROL SYMBOLS & ABBREVIATIONS

M-801 FY20PN88658M-801.dwg CONTROL DIAGRAMS

M-802 FY20PN88658M-802.dwg CONTROL DIAGRAMS

M-803 FY20PN88658M-803.dwg CONTROL DIAGRAMS

M-804 FY20PN88658M-804.dwg CONTROL DIAGRAMS

M-805 FY20PN88658M-805.dwg CONTROL DIAGRAMS

M-806 FY20PN88658M-806.dwg CONTROL DIAGRAMS

M-807 FY20PN88658M-807.dwg CONTROL DIAGRAMS

M-808 FY20PN88658M-808.dwg CONTROL DIAGRAMS

ELECTRICAL

E-001 FY20PN88658E-001.dwg ELECTRICAL LEGEND

EG101A FY20PN88658EG101.dwg FIRST FLOOR GROUNDING PLAN - AREA A

EG101B FY20PN88658EG101B.dwg FIRST FLOOR GROUNDING PLAN - AREA B

EG102A FY20PN88658EG102A.dwg SECOND FLOOR GROUNDING PLAN - AREA A

EG102B FY20PN88658EG102B.dwg SECOND FLOOR GROUNDING PLAN - AREA B

EG103A FY20PN88658EG103A.dwg LIGHTNING PROTECTION PLAN - AREA A

EG103B FY20PN88658EG103B.dwg LIGHTNING PROTECTION PLAN - AREA B

EG400 FY20PN88658EG400.dwg LIGHTNING PROTECTION AND GROUNDING ENLARGED PLAN

EG401 FY20PN88658EG401.dwg SITE LIGHTNING PROTECTION AND GROUNDING PLAN

EG601 FY20PN88658EG601.dwg GROUNDING RISER DIAGRAM

EL101A FY20PN88658EL101A.dwg FIRST FLOOR LIGHTING PLAN - AREA A

EL101B FY20PN88658EL101B.dwg FIRST FLOOR LIGHTING PLAN - AREA B

EL102A FY20PN88658EL102A.dwg SECOND FLOOR LIGHTING PLAN - AREA A

EL102B FY20PN88658EL102B.dwg SECOND FLOOR LIGHTING PLAN - AREA B

EL401 FY20PN88658EL401.dwg LIGHTING SECTIONS

EL402 FY20PN88658EL402.dwg LOBBY AND VESTIBULE LIGHTING PLAN

EL501 FY20PN88658EL501.dwg LIGHTING PLATES

EL502 FY20PN88658EL502.dwg LIGHTING PLATES

EL503 FY20PN88658EL503.dwg LIGHTING PLATES

EL701A FY20PN88658EL701A.dwg FIRST FLOOR NORMAL LIGHTING PLAN POINT BY POINT - AREA A

EL701B FY20PN88658EL701B.dwg FIRST FLOOR NORMAL LIGHTING PLAN POINT BY POINT - AREA B

INDEX OF DRAWINGS - VOLUME I

SHEET ID FILENAME SHEET TITLE

ARCHITECTURE

A-001 FY20PN88658A-001.dwg GENERAL NOTES AND LEGENDS

A-100 FY20PN88658A-100.dwg SECURITY AND STC PLAN

A-101 FY20PN88658A-101.dwg FIRST FLOOR PLAN - OVERALL

A-101A FY20PN88658A-101A.dwg FIRST FLOOR PLAN - AREA A

A-101B FY20PN88658A-101B.dwg FIRST FLOOR PLAN - AREA B

A-102 FY20PN88658A-102.dwg SECOND FLOOR PLAN - OVERALL

A-102A FY20PN88658A-102A.dwg SECOND FLOOR PLAN - AREA A

A-102B FY20PN88658A-102B.dwg SECOND FLOOR PLAN - AREA B

A-103 FY20PN88658A-103.dwg ROOF PLAN

A-111 FY20PN88658A-111.dwg FIRST FLOOR REFLECTED CEILING PLAN - OVERALL

A-111A FY20PN88658A-111A.dwg FIRST FLOOR REFLECTED CEILING PLAN - AREA A

A-111B FY20PN88658A-111B.dwg FIRST FLOOR REFLECTED CEILING PLAN - AREA B

A-112 FY20PN88658A-112.dwg SECOND FLOOR REFLECTED CEILING PLAN - OVERALL

A-112A FY20PN88658A-112A.dwg SECOND FLOOR REFLECTED CEILING PLAN - AREA A

A-112B FY20PN88658A-112B.dwg SECOND FLOOR REFLECTED CEILING PLAN - AREA B

A-122A FY20PN88658A-122A.dwg RAISED ACCESS FLOOR PLAN - AREA A

A-201 FY20PN88658A-201.dwg BUILDING ELEVATIONS

A-202 FY20PN88658A-202.dwg ENLARGED ELEVATIONS

A-203 FY20PN88658A-203.dwg ENLARGED ELEVATIONS

A-204 FY20PN88658A-204.dwg ENLARGED ELEVATIONS

A-205 FY20PN88658A-205.dwg CLERESTORY ELEVATIONS

A-301 FY20PN88658A-301.dwg BUILDING SECTIONS

A-302 FY20PN88658A-302.dwg BUILDING SECTIONS

A-303 FY20PN88658A-303.dwg ENLARGED BUILDING SECTIONS

A-310 FY20PN88658A-310.dwg WALL SECTIONS

A-311 FY20PN88658A-311.dwg WALL SECTIONS

A-312 FY20PN88658A-312.dwg WALL SECTIONS

A-313 FY20PN88658A-313.dwg WALL SECTIONS

A-314 FY20PN88658A-314.dwg WALL SECTIONS

A-315 FY20PN88658A-315.dwg WALL SECTIONS

A-316 FY20PN88658A-316.dwg WALL SECTIONS

A-317 FY20PN88658A-317.dwg WALL SECTIONS

A-401 FY20PN88658A-401.dwg ENLARGED STAIR

A-402 FY20PN88658A-402.dwg ENLARGED STAIR

A-403 FY20PN88658A-403.dwg ENLARGED STAIR

A-404 FY20PN88658A-404.dwg ENLARGED RESTROOM AND ELEVATIONS

A-405 FY20PN88658A-405.dwg ENLARGED LOCKER ROOM AND ELEVATIONS

A-406 FY20PN88658A-406.dwg ENLARGED PLANS AND ELEVATIONS

A-407 FY20PN88658A-407.dwg ENLARGED PLANS AND ELEVATIONS

A-408 FY20PN88658A-408.dwg ENLARGED VESTIBULE

A-410 FY20PN88658A-410.dwg POL STORAGE BUILDING - PLANS AND ELEVATIONS

A-411 FY20PN88658A-411.dwg POL STORAGE BUILDING - SECTIONS

A-501 FY20PN88658A-501.dwg EXTERIOR WALL DETAILS

A-502 FY20PN88658A-502.dwg EXTERIOR WALL BASE DETAILS

A-503 FY20PN88658A-503.dwg CLERESTORY DETAILS

A-504 FY20PN88658A-504.dwg ROOF DETAILS

A-505 FY20PN88658A-505.dwg ROOF DETAILS

A-506 FY20PN88658A-506.dwg ROOF DETAILS

A-510 FY20PN88658A-510.dwg STAIR & RAILING DETAILS

A-511 FY20PN88658A-511.dwg STAIR AND RAILING DETAILS

A-520 FY20PN88658A-520.dwg PLAN DETAILS

A-530 FY20PN88658A-530.dwg INTERIOR DETAILS

A-535 FY20PN88658A-535.dwg CASEWORK DETAILS

A-536 FY20PN88658A-536.dwg CASEWORK DETAILS

A-537 FY20PN88658A-537.dwg CASEWORK DETAILS

A-540 FY20PN88658A-540.dwg TRANSLUCENT WALL DETAIL

A-601 FY20PN88658A-601.dwg PARTITION TYPES

A-602 FY20PN88658A-602.dwg DEMOUNTABLE PARTITION TYPES

A-603 FY20PN88658A-603.dwg DOOR SCHEDULE & DOOR TYPES

A-610 FY20PN88658A-610.dwg DOOR DETAILS

A-611 FY20PN88658A-611.dwg DOOR DETAILS

A-621 FY20PN88658A-621.dwg WINDOW DETAILS

A-622 FY20PN88658A-622.dwg EXTERIOR WINDOW ELEVATIONS

A-623 FY20PN88658A-623.dwg EXTERIOR WINDOW ELEVATIONS

A-625 FY20PN88658A-625.dwg INTERIOR WINDOW ELEVATIONS

A-630 FY20PN88658A-630.dwg EXTERIOR LOUVER ELEVATIONS

A-640 FY20PN88658A-640.dwg MULLION DETAILS

A-801 FY20PN88658A-801.dwg FIRST FLOOR PLAN - AIR BARRIER

A-802 FY20PN88658A-802.dwg SECOND FLOOR PLAN - AIR BARRIER

A-803 FY20PN88658A-803.dwg BUILDING SECTIONS - AIR BARRIER

A-804 FY20PN88658A-804.dwg AIR BARRIER - LONGITUDINAL BUILDING SECTION

A-805 FY20PN88658A-805.dwg AIR BARRIER DETAILS

INTERIORS

IN101 FY20PN88658IN101.dwg FIRST FLOOR FINISH PLAN - OVERALL

IN101A FY20PN88658IN101A.dwg FIRST FLOOR FINISH PLAN - AREA A

IN101B FY20PN88658IN101B.dwg FIRST FLOOR FINISH PLAN - AREA B

IN102 FY20PN88658IN102.dwg SECOND FLOOR FINISH PLAN - OVERALL

IN102A FY20PN88658IN102A.dwg SECOND FLOOR FINISH PLAN - AREA A

IN102B FY20PN88658IN102B.dwg SECOND FLOOR FINISH PLAN - AREA B

IN401 FY20PN88658IN401.dwg ENLARGED FINISH PLANS

IN501 FY20PN88658IN501.dwg TRANSITION DETAILS

IN502 FY20PN88658IN502.dwg TRANSITION DETAILS

IN601 FY20PN88658IN601.dwg FINISH LEGEND

IN602 FY20PN88658IN602.dwg ROOM FINISH SCHEDULE

IF101 FY20PN88658IF101.dwg FIRST FLOOR FURNITURE PLAN - OVERALL

IF101A FY20PN88658IF101A.dwg FIRST FLOOR FURNITURE PLAN - AREA A

IF101B FY20PN88658IF101B.dwg FIRST FLOOR FURNITURE PLAN - AREA B

IF102 FY20PN88658IF102.dwg SECOND FLOOR FURNITURE PLAN - OVERALL

IF102A FY20PN88658IF102A.dwg SECOND FLOOR FURNITURE PLAN - AREA A

IF102B FY20PN88658IF102B.dwg SECOND FLOOR FURNITURE PLAN - AREA B

IF601 FY20PN88658IF601.dwg FURNITURE SCHEDULES

IG101 FY20PN88658IG101.dwg FIRST FLOOR SIGNAGE PLAN - OVERALL

IG101A FY20PN88658IG101A.dwg FIRST FLOOR SIGNAGE PLAN - AREA A

IG101B FY20PN88658IG101B.dwg FIRST FLOOR SIGNAGE PLAN - AREA B

IG102 FY20PN88658IG102.dwg SECOND FLOOR SIGNAGE PLAN - OVERALL

IG102A FY20PN88658IG102A.dwg SECOND FLOOR SIGNAGE PLAN - AREA A

IG102B FY20PN88658IG102B.dwg SECOND FLOOR SIGNAGE PLAN - AREA B

IG601 FY20PN88658IG601.dwg SIGNAGE SCHEDULE

INDEX OF DRAWINGS - VOLUME I

SHEET ID FILENAME SHEET TITLE

GENERAL

G-001.1 FY20PN88658G-001.1.dwg COVER SHEET - VOLUME I

G-001.2 FY20PN88658G-001.2.dwg COVER SHEET - VOLUME II

G-002 FY20PN88658G-002.dwg FT. BRAGG CANTONMENT

G-003 FY20PN88658G-003.dwg INDEX OF DRAWINGS

G-004 FY20PN88658G-003.dwg ABBREVIATIONS

G-005 FY20PN88658G-004.dwg GENERAL SYMBOLOGY

G-006 FY20PN88658G-005.dwg TYPICAL MOUNTING HEIGHTS

LIFE SAFETY

GI001 FY20PN88658GI001.dwg LIFE SAFETY CODE ANALYSIS

GI002 FY20PN88658GI002.dwg EMERGENCY VEHICLE ACCESS

GI101 FY20PN88658GI101.dwg FIRST FLOOR LIFE SAFETY PLAN

GI102 FY20PN88658GI102.dwg SECOND FLOOR LIFE SAFETY PLAN

CIVIL

VF100 FY20PN88658VF100.dwg SURVEY & NOTES

VF101 FY20PN88658VF101.dwg EXISTING TOPOGRAPHY 1

VF102 FY20PN88658VF102.dwg EXISTING TOPOGRAPHY 2

B-101 FY20PN88658B-101.dwg BORING LOCATION PLAN 1

B-102 FY20PN88658B-102.dwg BORING LOCATION PLAN 2

BB601 FY20PN88658BB601.dwg SOIL TEST BORING LOGS 1

BB602 FY20PN88658BB602.dwg SOIL TEST BORING LOGS 2

BB603 FY20PN88658BB603.dwg SOIL TEST BORING LOGS 3

BB604 FY20PN88658BB604.dwg SOIL TEST BORING LOGS 4

BB605 FY20PN88658BB605.dwg SOIL TEST BORING LOGS 5

BB606 FY20PN88658BB606.dwg SOIL TEST BORING LOGS 6

CD101 FY20PN88658CD101.dwg SITE DEMOLITION PLAN 1

CD102 FY20PN88658CD102.dwg SITE DEMOLITION PLAN 2

CS101 FY20PN88658CS101.dwg SITE UTILITIES PLAN 1

CS102 FY20PN88658CS102.dwg SITE UTILITIES PLAN 2

CS201 FY20PN88658CS201.dwg SIGNAGE & MARKINGS PLAN 1

CS202 FY20PN88658CS202.dwg SIGNAGE & MARKINGS PLAN 2

CS501 FY20PN88658CS502.dwg SITE DETAILS 1

CS502 FY20PN88658CS502.dwg SITE DETAILS 2

CG101 FY20PN88658CG101.dwg SITE GRADING PLAN 1

CG102 FY20PN88658CG102.dwg SITE GRADING PLAN 2

CG103 FY20PN88658CG103.dwg STORM DRAINAGE PLAN 1

CG104 FY20PN88658CG104.dwg STORM DRAINAGE PLAN 2

CG105 FY20PN88658CG105.dwg EROSION CONTROL PHASE I PLAN 1

CG106 FY20PN88658CG106.dwg EROSION CONTROL PHASE I PLAN 2

CG107 FY20PN88658CG107.dwg EROSION CONTROL PHASE II PLAN 1

CG108 FY20PN88658CG108.dwg EROSION CONTROL PHASE II PLAN 2

CG109 FY20PN88658CG109.dwg EROSION CONTROL PHASE III PLAN 1

CG110 FY20PN88658CG110.dwg EROSION CONTROL PHASE III PLAN 2

CG201 FY20PN88658CG201.dwg STORM DRAINAGE PROFILES 1

CG202 FY20PN88658CG202.dwg STORM DRAINAGE PROFILES 2

CG501 FY20PN88658CG501.dwg STORM DRAINAGE DETAILS

CG502 FY20PN88658CG502.dwg STORM DRAINAGE DETAILS 2

CG503 FY20PN88658CG503.dwg STORM DRAINAGE DETAILS 3

CG504 FY20PN88658CG504.dwg STORM DRAINAGE DETAILS 4

CG505 FY20PN88658CG505.dwg N.P.D.E.S. CHECKLIST 1

CG506 FY20PN88658CG506.dwg N.P.D.E.S CHECKLIST 2

CG507 FY20PN88658CG507.dwg EROSION CONTROL DETAILS & NOTES 1

CG508 FY20PN88658CG509.dwg EROSION CONTROL DETAILS & NOTES 2

CG509 FY20PN88658CG509.dwg EROSION CONTROL DETAILS & NOTES 3

CG510 FY20PN88658CG510.dwg EROSION CONTROL DETAILS & NOTES 4

CG511 FY20PN88658CG511.dwg EROSION CONTROL DETAILS & NOTES 5

CG512 FY20PN88658CG512.dwg EROSION CONTROL DETAILS & NOTES 6

CG513 FY20PN88658CG513.dwg EROSION CONTROL DETAILS & NOTES 7

CG514 FY20PN88658CG514.dwg EROSION CONTROL DETAILS & NOTES 8

CG515 FY20PN88658CG515.dwg EROSION CONTROL DETAILS & NOTES 9

CG516 FY20PN88658CG516.dwg EROSION CONTROL DETAILS & NOTES 10

CG517 FY20PN88658CG517.dwg EROSION CONTROL DETAILS & NOTES 11

CG518 FY20PN88658CG518.dwg EROSION CONTROL DETAILS & NOTES 12

CG519 FY20PN88658CG519.dwg ADDITIONAL NOTES

CU201 FY20PN88658CU201.dwg SITE UTILITIES PLAN 1

CU202 FY20PN88658CU202.dwg SITE UTILITIES PLAN 2

CU203 FY20PN88658CU203.dwg SANITARY SEWER PROFILES

CU501 FY20PN88658CU501.dwg SANITARY SEWER DETAILS 1

CU502 FY20PN88658CU502.dwg SANITARY SEWER DETAILS 2

CU503 FY20PN88658CU503.dwg WATER DETAILS

L-101 FY20PN88658L-101.dwg LANDSCAPING PLAN 1

L-102 FY20PN88658L-102.dwg LANDSCAPING PLAN 2

STRUCTURAL

S-001 FY20PN88658S-001 GENERAL NOTES

S-002 FY20PN88658S-002 WIND C&C DIAGRAM

S-101 FY20PN88658S-101 FOUNDATION PLAN - OVERALL

S-101A FY20PN88658S-101A FOUNDATION PLAN - AREA A

S-101B FY20PN88658S-101B FOUNDATION PLAN - AREA B

S-102 FY20PN88658S-102 SECOND FLOOR FRAMING PLAN - OVERALL

S-102A FY20PN88658S-102A SECOND FLOOR FRAMING PLAN - AREA A

S-102B FY20PN88658S-102B SECOND FLOOR FRAMING PLAN - AREA B

S-103 FY20PN88658S-103 ROOF FRAMING PLAN - OVERALL

S-103A FY20PN88658S-103A ROOF FRAMING PLAN - AREA A

S-103B FY20PN88658S-103B ROOF FRAMING PLAN - AREA B

S-201 FY20PN88658S-201 BRACED FRAME ELEVATIONS

S-202 FY20PN88658S-202 BRACED FRAME ELEVATIONS

S-203 FY20PN88658S-203 TRUSS ELEVATIONS

S-301 FY20PN88658S-301 SECTION & DETAILS

S-302 FY20PN88658S-302 SECTION & DETAILS

S-303 FY20PN88658S-303 SECTION & DETAILS

S-304 FY20PN88658S-304 SECTION & DETAILS

S-305 FY20PN88658S-305 SECTION & DETAILS

S-306 FY20PN88658S-306 SECTION & DETAILS

S-307 FY20PN88658S-307 SECTION & DETAILS

S-308 FY20PN88658S-308 SECTION & DETAILS

S-309 FY20PN88658S-309 SECTION & DETAILS

S-310 FY20PN88658S-310 SECTION & DETAILS

S-311 FY20PN88658S-311 SECTION & DETAILS

S-401 FY20PN88658S-401 ENLARGED PLANS

S-402 FY20PN88658S-402 ENLARGED PLANS

S-403 FY20PN88658S-403 ENLARGED PLANS - AREA C

S-404 FY20PN88658S-404 ENLARGED PLAN - BID OPTION 1

S-501 FY20PN88658S-501 TYPICAL DETAILS

S-502 FY20PN88658S-502 TYPICAL DETAILS

S-503 FY20PN88658S-503 TYPICAL DETAILS

S-504 FY20PN88658S-504 TYPICAL DETAILS

S-601 FY20PN88658S-601 SCHEDULES

SHEET TA111B

REMOVED BY WAY

OF AMENDMENT 0005

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A m e n d m e n t

J

A N

US Army Corps of Engineers ® Wilmington District

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

C A

T E

G O

R Y

C O

D E

1 2 3 4 5

A

F O

R T

B R

A G

G N

O R

T H

C A

R O

L

IN

A S

O F

O P

E R

A T

IO

N

S F

A C

IL

IT

Y F

Y

P

N

W

IL

M

IN

G T

T

R

IC

T W

IL

M

IN

G

T O

N N

O R

T H

C A

R O

L

IN

A

A E

C…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .