W912PL20R0001_FFE_Package_1-Haworth_R3.pdf
PDF 41 MB Posted
- Attached to
- Brownfield Border Patrol Station Federal contract opportunity
- Solicitation number
- W912PL20R0001
About this file
This federal contract opportunity notice solicits proposals for the construction of the Brownfield Border Patrol Station project. Key details include that the project scope involves constructing a 53,500 square foot facility capable of supporting 400 agents and detaining 130 individuals. It will include a detention area and two-lane sally port. The cost range is $25-100 million and period of performance is 720 days. The solicitation is posted on FBO.gov and proposals are due via a one-step LPTA request for proposals process. The NAICS code is 236220 and small business size standard is $39.5 million. The Army Corps of Engineers is the contracting agency.
W912PL20R0001 FFE Package 1
View the file
Other files for this federal contract opportunity
Show all 19
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FURNITURE FIXTURES AND EQUIPMENT
SPECIFICATIONS PACKAGE
BID PACKAGE 1 : SOLE SOURCED HAWORTH
GOVERNMENT FURNISHED / GOVERNMENT INSTALLED
(GFGI)
BUILDING 1: BORDER PATROL STATION
BUILDING 2: VEHICLE MAINTENANCE FACILITY
BROWN FIELD BORDER PATROL STATION
DULZURA, CALIFORNIA
SOLICITATION NUMBER :W912PL-20-R-0001
11 OCTOBER 2019
TA
B
LE
O
F C O
N
TE
N
TS
TABLE OF CONTENTS
I. SPECIFICATION SECTIONS
A. 12 50 00.13.10 FURNITURE AND FURNITURE INSTALLATION (GFGI)
B. 12 50 00 SYSTEMS FURNITURE
II. MANUFACTURER REPRESENTATIVE CONTACT INFORMATION
III. FURNITURE INDEX
IV. FORM OF PROPOSAL
V. EXHIBITS
A. BUILDING 1 : BORDER PATROL STATION
1) 1-I300 OVERALL FURNITURA PLAN
2) 1-I301 FURNITURE PLAN - AREA A
3) 1-I302 FURNITURE PLAN - AREA B
4) 1-I303 FURNITURE PLAN - AREA C
5) 1-I304 FURNITURE PLAN - AREA D
6) 1-305 FURNITURE PLAN - AREA E
7) 1-306 FURNITURE & EQUIPMENT SCHEDULE
B. BUILDING 2: VEHICLE MAINTENANCE FACILITY
1) 2-I201 FURNITURE PLAN
2) 2-I202 FURNITURE & EQUIPMENT SCHEDULE
VI. FURNITURE SPECIFICATIONS
I. S P
E C
IFIC
A
TIO
N
S E
C
TIO
N S
Brown Field Border Patrol Station, CA BROWNFIELD
SECTION 12 50 00.13 10
FURNITURE AND FURNITURE INSTALLATION (GFGI)
08/17
PART 1 GENERAL
Purchase and install furniture as identified within this specification.
This specification section includes a Furniture, Fixtures and Equipment (FF&E) Package attachment.
The requirements of this specification also apply to systems furniture unless otherwise specified in Section 12 59 00 Systems Furniture.
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING
ENGINEERS (ASHRAE)
ASHRAE 90.1 - IP (2016; ERTA 1-8 2017; INT 1-5 2017) Energy Standard for Buildings Except Low-Rise Residential Buildings
ASTM INTERNATIONAL (ASTM)
ASTM D4157 (2013; R 2017) Standard Test Method for Abrasion Resistance of Textile Fabrics (Oscillatory Cylinder Method)
ASTM E84 (2017) Standard Test Method for Surface Burning Characteristics of Building Materials
BIFMA INTERNATIONAL (BIFMA)
ANSI/BIFMA X5.1 (2017) American National Standards For Office Furnishings - General Purpose Office Chairs
ANSI/BIFMA X5.3 (2007; R2012) American National Standards For Office Furnishings - Vertical Files
ANSI/BIFMA X5.4 (2012) American National Standards For Office Furnishings - Lounge Seating
ANSI/BIFMA X5.5 (2014) American National Standards For Office Furnishings -Desk Products
ANSI/BIFMA X5.6 (2016) American National Standards For Office Furnishings -Panel Systems
ANSI/BIFMA X5.9 (2012) American National Standards For Office Furnishings - Storage Units
SECTION 12 50 00.13 10 Page 1
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 101 (2018; TIA 18-1) Life Safety Code
NFPA 265 (2015) Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Coverings on Full Height Panels and Walls
TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA)
TIA-568-C.2 (2009; Errata 2010; Add 2 2014; Add 1 2016) Balanced Twisted-Pair Telecommunications Cabling and Components Standards
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
UNDERWRITERS LABORATORIES (UL)
UL 723 (2008; Reprint Aug 2013) Test for Surface Burning Characteristics of Building Materials
FAR - Federal Acquisition regulations
1.2 DEFINITIONS
GFGI - Goverment Furnished, Government Installed.
1.3 COORDINATION
Manufacturer / supplier is to review and coordinate funiture layout with electrical and telecommunications drawings. Report descrepencies and coorinate any required changes to the Project Manager and Architect prior to submittals and electrical installation.
1.4 SUBMITTALS
Government approval is required for submittals with a "G" designation;
Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES:
SD-01 Preconstruction Submittals
Storage Location
SD-02 Shop Drawings
Installation Drawings; G
Grommet, Power and Communication Units, and Wire Management Locations; G
SECTION 12 50 00.13 10 Page 2
SD-03 Product Data
Product Data; G
Product Style Options
SD-04 Samples
Fabric and Finishes; G
SD-07 Certificates
Authorized Dealer
Certified Furniture Installers
Licensed Electrician
Certified Telecommunications Installer
Manufacturer's Certification
Warranty
SD-10 Operation and Maintenance Data
Furniture, Data Package; G
SD-11 Closeout Submittals
Energy Efficient Equipment
Reduced VOC's for Furniture
Recycled Content of Furniture
Bio-Based Content of Furniture
1.5 SERVICES
Provide services to include furniture purchase, field measuring, installation drawings, shipping and delivery coordination, receiving, inspection, submitting and processing freight and warranty claims, unpacking, storing, assembly, installation and other related activities or tasks for a complete and functional installation. Reference Section 01 45 00.00 10 QUALITY CONTROL for inspection requirements. The Contracting Officer must be allowed to participate in inspections.
Develop project timelines and establish shipping, receiving and installation dates that coordinate with the building construction schedule. Hold at a minimum weekly team meetings to brief the project team, include the Contracting Officer. Notify the Contracting Officer immediately of any scheduling problems, discontinued furniture items including fabrics and finishes, or other conditions which may cause delays, and recommend available substitutes, solutions, and provide updated timeline to coordinate with building construction schedule.
Substitutes and solutions must comply with the specification and be approved by the Contracting Officer.
SECTION 12 50 00.13 10 Page 3
1.6 FURNITURE PURCHASE
Purchase furniture, including checking accuracy of all acknowledgements and schedules from manufacturers and making necessary corrections to insure that the manufacturer has a correct understanding of the order and requirement. Provide furniture from the GSA Schedules and provide GSA pricing. Provide furniture from open market only when an item is not available on the GSA Schedules. See FAR clause 52.251-1 Government Supply Sources. Purchase furniture from the open market. The furniture provided needs to be available on the GSA Schedules to assist the User with future purchases. GSA information is provided FOR INFORMATIONAL PURPOSES ONLY.
It is encouraged to solicit and provide GSA pricing on furniture. Compete the furniture purchase by obtaining a minimum of (3) separate proposals.
Furniture is subject to FAR clause 52.236-5 Materials and Workmanship.
1.7 ALTERNATE DESIGN
When a manufacturer's product is unable to provide desk and workstation configurations and filing/storage that conform exactly to the furniture layouts shown in the contract drawings and specifications, alternate designs may be submitted for consideration by the Contracting Officer.
Alternate designs must meet or exceed the following criteria. Alternate designs that are submitted but do not meet these criteria will be rejected.
1.7.1 Desk and Workstation Size and Configuration
The alternate design must provide desks and workstations of the same basic size and configuration shown, with only the sizes of the individual components within the desk and workstation changed to meet the standard product of the manufacturer.
1.7.2 Filing and Storage Size and Configuration
The alternate design must provide filing and storage of the same basic size and configuration shown, with only the size changed to meet the standard product of the manufacturer. The storage capacity must not be reduced.
1.7.3 Furniture Requirements
The furniture provided must comply with the drawings, specifications, and the requirements identified in the FF&E Package Attachment.
1.7.4 Layout
The storage capacity, number of desks and workstations, number of persons accommodated, width of aisles, and functionality must be maintained.
Layout must comply with NFPA 101 and 36 CFR 1191 .
1.8 AUTHORIZED DEALER, CERTIFIED FURNITURE INSTALLERS, LICENSED ELECTRICIAN
AND CERTIFIED TELECOMMUNICATIONS INSTALLER
When required by the furniture manufacturer, furniture must be installed by an authorized dealer and a certified furniture installation crew must be used on the project. All furniture requiring hardwiring must be completed by a licensed electrician. Communications installers must be Building Industry Consulting Services International (BICSI) Registered Cabling Installers, Technician Level or have a minimum of 3 years experience in the installation of the specified cables and components.
SECTION 12 50 00.13 10 Page 4
All installers, furniture, electrical and communications, must be on-site if questions arise. Submit copies of authorized dealer, furniture installation crew, licensed electrician and certified telecommunications installer certifications.
1.9 DELIVERY, STORAGE AND HANDLING
1.9.1 Delivery
Deliver furniture to the jobsite in manufacturer's original packaging or blanket wrapping. Original packaging must be marked with the manufacturer name, item identification, and project reference clearly marked.
1.9.2 Furniture Inspection
Inspect furniture and provide notification of damage within the time frame required by the shipping company while carrier is still on-site. Complete claims for concealed damage within the time frame required by the shipping company and furniture manufacturer. A claim file must be maintained that documents each claim. Forward copies of claims to the Contracting Officer on a daily basis.
1.9.3 Storage
Storage space is not available on-site and furniture must be stored at an off site location. Provide any storage space required for furniture and transport stored furniture to the project site for installation. Storage location must be approved by the Contracting Officer at the time of the furniture order. If storage is required, furniture must be stored in a dry location that is adequately ventilated and free from dirt and dust, water, and other contaminants, in a manner that permits easy access for inspection and handling, and in an environment in accordance with furniture manufacturers instructions.
1.9.4 Furniture Staging Area
Coordinate location of the furniture staging area with the Contracting Officer.
1.10 WARRANTY
Provide manufacturer performance guarantees or warranties for single-shift service and include parts, labor and transportation as follows, unless otherwise noted:
a. Systems Furniture - see Section12 59 00 Systems Furniture12 year minimum
b. Desks and Workstations - 12 year minimum
c. Filing and Storage - 12 year minimum
d. Seating
(1) Seating, unless otherwise noted - 10 year minimum
(2) 24/7 Seating (multiple shift use) - 10 year minimum
(3) Seating Mechanisms and Pneumatic Cylinders - 10 year minimum
SECTION 12 50 00.13 10 Page 5
(4) Lounge Seating - 10 year minimum
(5) Stacking Chairs - 10 year minimum
e. Tables
(1) Unless otherwise noted - 10 year minimum
(2) Table Mechanisms - 5 year minimum
(3) Table Ganging Device - 1 year minimum
f. Miscellaneous
(1) Fabric - 3 year minimum
(2) LED Task Lighting - 5 year minimum
(3) Task Lighting - 3 year minimum
Provide items not listed with a 1 year minimum. When manufacturers standard performance guarantees or warranties exceed the minimum requirements identified, provide the standard performance guarantee or warranty. Submit manufacturer's warranty information for all furniture items.
PART 2 PRODUCTS
2.1 PRODUCT SUSTAINABILITY CRITERIA
For products in this section, where applicable and to extent allowed by performance criteria, provide and document the following:
2.1.1 Energy Efficient Equipment
Coordinate requirement for energy efficient equipment, such as appliances and lighting.
2.1.2 Reduced VOC's for Furniture
Coordinate requirement for reduced VOC requirements for furniture and provide documentation.
2.1.3 Recycled Content of Furniture
Coordinate requirement for recycled content for furniture and provide documentationT.
2.1.4 Bio-Based Content of Furniture
Coordinate requirement for biobased content for furniture and provide documentation.
2.2 REFERENCE TO MANUFACTURER NAMES AND COLORS
Where product and color is shown as being specific to one manufacturer in the FF&E Package Attachment, an equivalent color or product by another manufacturer may be submitted for approval. Manufacturers, style lines, SECTION 12 50 00.13 10 Page 6 model numbers, finish, and fabric information are provided to establish design intent and are not intended to limit the selection of equal products and colors from other manufacturers.
2.3 FURNITURE REQUIREMENTS
Use the FF&E Package Attachment in conjunction with the drawings and specifications for the furniture requirements. Systems furniture is specified in Section 12 59 00 SYSTEMS FURNITURE. Provide furniture from manufacturer's standard product as shown in the most current published price list or amendment. Furniture provided must be part of current line as indicated with no intent to discontinue within two years. Provide furniture that is intended for commercial use not residential. submit product data for all furniture items, to include catalog cuts, brochures, product information, and other necessary literature to indicate compliance with specifications. Provide product data for all items together in a single submittal. Provide product data for all similar types of items together as a group, such as desks/workstations,seating, storage, tables.
Submit each grouping of similar type items in a single submittal. When applicable, include GSA schedule information to confirm that items are available on GSA schedule. Tag product data sheets with applicable furniture item code and name. Submit data for all product style options for selection when options are available. This applies to but is not limited to furniture items that have options such as edge details, hardware options, and grommet colors. Submit manufacturer's certification stating that furniture meets the specifications. 2.3.1 Construction
a. Provide furniture that complies with the following testing requirements:
(1) ANSI/BIFMA
(a) Office Seating - ANSI/BIFMA X5.1
(b) Vertical Files - ANSI/BIFMA X5.3
(c) Lounge Seating - ANSI/BIFMA X5.4
(d) Desk Products - ANSI/BIFMA X5.5
(e) Panel Systems - ANSI/BIFMA X5.6
(f) Storage - ANSI/BIFMA X5.9
(2) Flammability
(a) Systems furniture and workstation panel components must meet requirements for flame spread and smoke development as specified by NFPA 101 except as follows. Conduct testing in accordance with either ASTM E84 or UL 723 on the entire assembled panel of the worst case (most combustible) combination of fabric and interior construction. In addition, fabric must meet the requirements of NFPA 265 . Panel flame spread shall not exceed 25 for Class A
b. Provide furniture with no rough or sharp edges or exposed
SECTION 12 50 00.13 10 Page 7 connections. Clips, screws, and other construction elements must be concealed wherever possible.
c. Items such as desks, workstations and systems furniture must include all necessary components to be structurally sound and must not be attached to the wall unless specified to be wall mounted in the contract documents.
d. Desks, workstations, storage, and tables must have leveling devices to compensate for uneven floors.
e. The underside of desks, workstations, and tables must be completely and smoothly finished.
f. The backside of freestanding desks, workstations, and storage must be finished.
g. Provide chair casters and glides appropriate for the floor material they are located on, such as carpet and resilient flooring.
2.3.2 Locks and Keying
a. All drawers and doors, including but not limited to overhead storage cabinets, storage towers, supply cabinets, storage cabinets, desk and workstation pedestals, and filing cabinets must be lockable.
b. Key each desk and workstation in an office differently and key locks within each desk and workstation alike.
c. Furniture storage components in private offices must be keyed alike.
Key each private office differently.
d. Provide field changeable lock cylinders in desks and workstations with a minimum of 100 different key options. Number keys and lock cylinders for ease of replacement or clearly label locks with a key number, except for those manufacturers who have removable format locks.
e. Drawers within a pedestal must be lockable either by a central lock that controls all pedestals under one work surface or an individual keyed lock in each pedestal.
f. Central file and storage units which are grouped together but are not a part of a workstation must be keyed alike unless otherwise specified.
g. Provide two keys for each workstation when components are keyed alike. Also provide two keys for each miscellaneous item such as filing cabinets, supply cabinets, storage cabinets, and similar type furniture items.
h. Provide three copies of each master key to the Contracting Officer.
i.Inventory keys, label keys by lock number, room number and furniture item and turn over inventory and keys to the Contracting Officer.
2.3.3 Receptacle Bodies and Device Cover Plates
Provide furniture panel faceplates and receptacle body types as specified in FF&E Package Attachment
SECTION 12 50 00.13 10 Page 8
2.3.4 Keyboard Tray
Provide worksurfaces that are capable of accepting an articulating keyboard tray at locations indicated. The keyboard tray must be capable of fully recessing under the work surface and extending to give the user full access to the keyboard. The keyboard tray must have height adjustability and positive and negative tilting capability and have 180-degree swing side travel rotation. The keyboard tray must have a wrist support and include a mouse pad at the same level as the keyboard that can accommodate both right and left handed users.
2.3.5 Fabric and Finish
Submit samples of all furniture fabric and finishes. Samples must be actual samples, not photographic representations, size must be a minimum of 3 by 3 inches. If necessary, provide larger size samples to clearly represent pattern. Label samples with fabric or finish code, furniture item code and name, manufacturer name, and color information. Fabric samples must also be labeled with fiber content and double rub testing information.
2.3.5.1 Fabric
a. Fabric must be from manufacturer's standard line andgraded-in textile manufacturer's fabrics Do not provide COM fabrics.
b. Provide a mid grade fabric, unless otherwise noted.
c. Provide a topical or inherent soil retardant treatment where indicated.
d. Comply with double rub testing as specified in the FF&E Package Attachment. Perform double rub testing in accordance with the ASTM D4157 Wyzenbeek Method.
e. Provide vinyl, polypropylene or similar type fabric for seating only if allowed in FF&E Package Attachment.
f. Pattern:
(1) Provide patterned upholstery fabric to help hide soiling.
(2) Provide patterns as specified in the FF&E Package Attachment.
g. See FF&E Package Attachment for additional information.
2.3.5.2 Finishes
Provide furniture finishes as listed below unless otherwise noted:
a. Finishes must be able to be cleaned with ordinary household cleaning solutions. Wood finishes must be able to be cleaned with damp cloth as directed by the manufacturer.
b. The finish of steel surfaces must be the manufacturer's most durable finish such as factory powder coat or baked enamel.
c. Grommet colors must be compatible and coordinated with desk, workstation, and table finish colors.
f. See FF&E Package Attachment for additional information.
SECTION 12 50 00.13 10 Page 9
2.4 FURNITURE LAYOUT
Provide furniture layout as indicated.
PART 3 EXECUTION
3.1 BUILDING EXAMINATION
Become familiar with details of the work, inspect all areas and conditions under which furniture is to be installed, and coordinate scheduling of dedicated entrances. Notify the Contracting Officer in writing of any conditions detrimental to the proper and timely completion of the installation. Work will proceed only when conditions have been corrected.
Manufacturer/supplier and installer are to review and coordinate with electrical and telecommunications drawing prior to beginning installation.
Report descrepancies prior to starting work. Starting work is acceptance of the project conditions and the furniture contractor will be responsible for corrective measures, expenses and delays at to cost to the owner.
3.2 BUILDING PROTECTION
Protect building surfaces to prevent soiling and damage during delivery and installation. Any soiling and damage that occurs to the building during the installation of furniture must be cleaned and repaired, or replaced to its original condition and must be approved by the Contracting Officer.
3.3 INSTALLATION
3.3.1 Installation Drawings
Installation drawings must include furniture layout, critical dimensions and locations of electrical and communications. Furniture layouts shall reflect field verified conditions. Drawings must be at 1/4 inch = 1 foot scale, unless otherwise specified. Provide typical plans and isometrics/elevations of desks and workstations at a scale of 1/2 inch = 1 foot. When applicable, provide desk and workstation electrical and communications locations. When applicable include controlled-circuit identification for each furniture receptacle and coordinate with the building electrical system circuits in accordance with ASHRAE 90.1 - IP .
Critical dimensions include, but are not limited to clearances and aisle widths. Drawings must include layout for furniture systems workstations for coordination purposes. Label furniture with furniture item code identified in this specification. Submit grommet, power and communication units, and wire management locations.
3.3.2 Furniture Installation Procedures
Complete installation in accordance with manufacturer's installation instructions, assembly manuals, warranty requirements and approved installation drawings. Also comply with the following requirements:
a. Use material handling equipment with rubber wheels.
b. Furniture and components must be installed level, plumb, square, and with proper alignment with adjoining furniture.
SECTION 12 50 00.13 10 Page 10
c. Match keys to locks and check locking mechanisms.
d. Check drawers, doors, lighting, and other operable items and mechanisms for proper operation.
e. Remove all protective wrapping tape, residue, and related type items.
f. Securely interconnect furniture components where required.
g. Securely attach and anchor furniture components to the building when required.
h. Securely anchor furniture such as shelving and storage units to the building when required by the manufacturer.
i. All items with an electrical plug, such as but not limited to task lighting and tables with electrical power, must be fully operational .
j. All hardwired furniture, such as but not limited to furniture systems, must be fully operational. Verify that voltage is present in electrical outlets. Verify controlled-circuit outlets are properly configured in accordance with the installation drawings.
k. Furniture must not block SIPRNETand jacks or the jack enclosures on walls. Report conflicts to Contracting Officer to discuss resolution.
l. Upon completion of installation, all furniture must be completely cleaned, finished, leveled, aligned, operational and functional.
3.3.3 Furniture Communications Installation
Provide all Information/Technology (IT) cables (i.e. SIPRNET, NIPRNET, J-WIC'S, etc.) and phone wiring up to and including the face plate/box of all furniture as required and the services to install the cables, wiring and face plates/boxes in the furniture. Coordinate cable type, cable jacket and outlet jack color with Section 27 10 00 BUILDING TELECOMMUNICATIONS CABLING SYSTEM. Furniture communication installers must be on site to install communication cables, wiring and other components for furniture during furniture installation. Coordinate the TIA-568-C.2 pin/pair assignments for communication outlets to match the configuration of the building's non-furniture outlets; coordinate with Contracting Officer. All items with a communication interface must be fully operational.Installation of Information/Technology (IT) wiring, cables and face plates/boxes in the furniture will be completed by others.
3.4 CLEANING
Remove all packing materials and other trash from the jobsite. Upon completion of installation, all products must be clean, including inside all drawers and doors, and the area must be free of debris and left in a clean and neat condition. Any defects in or damage to furniture must be repaired or replaced and approved by the Contracting Officer. Damaged products that cannot be satisfactorily repaired must be replaced. Correct any problems with assembly and installation. Prior to any furniture repair, replacement, and/or assembly and installation corrections, protect the building surfaces.
SECTION 12 50 00.13 10 Page 11
3.5 OPERATION AND MAINTENANCE MANUALS
Submit the Furniture, Data Package 1 in accordance with Section 01 78 23 OPERATION AND MAINTENANCE DATA and include the following:
3.5.1 Assembly Manuals
Describe assembly and re-configuration procedures.
3.5.2 Installation Instructions
Provide a copy of the instructions used to install the furniture. Also describe any special procedures or helpful hints learned during the installation process.
3.5.3 Maintenance Manuals
Describe proper cleaning and minor repair procedures, include cleaning instructions for fabrics.
3.5.4 Electrical System Manuals
Describe the functions, configuration, and maintenance of the furniture electrical system (power, communication, and data). This information may be included in the assembly or maintenance manuals.
3.5.5 Special Tools
Provide three sets of special tools necessary for assembly and disassembly of furniture and components from each manufacturer. Mark tool(s) with manufacturer and product information.
3.5.6 Furniture Drawings
Provide hard copy and electronic, showing installed furniture layout.
Include all modifications. Provide electronic copies on a CD-ROM.
Coordinate type (such as but not limited to Microstation, AutoCad and Revit) and version required with User. Include critical dimensions, and locations of building and furniture electrical and communications. Provide drawings at 1/4 inch = 1 foot scale, unless otherwise specified. Provide typical plans and isometrics/elevations of workstations at a scale of 1/2 inch = 1 foot. Code all furniture with furniture item code identified in this specification.
3.5.7 Furniture Listing
Provide complete listing, hard copy and electronic, of furniture provided. Include all modifications. Provide electronic copies on a CD-ROM. Coordinate type of electronic file required with User (such as but not limited to Word and Excel). Listing must include furniture item code and name used in FF&E Package, part/model numbers, fabrics and finishes for all components furnished. Organize listing by item name and code and provide building totals.
3.5.8 Order Form Documentation
Provide Order Form Documentation with Purchase Order number and project name and location to allow the User to follow up on warranty issues and help with future purchases.
SECTION 12 50 00.13 10 Page 12
-- End of Section --
SECTION 12 50 00.13 10 Page 13
SECTION 12 59 00
SYSTEMS FURNITURE (GFGI)
08/17
PART 1 GENERAL
Purchase and install furniture as identified within this specification.
This specification section includes a Furniture, Fixtures and Equipment (FF&E) Package attachment.
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING
ENGINEERS (ASHRAE)
ASHRAE 90.1 - IP (2016; ERTA 1-8 2017; INT 1-5 2017) Energy Standard for Buildings Except Low-Rise Residential Buildings
ASTM INTERNATIONAL (ASTM)
ASTM E84 (2017) Standard Test Method for Surface Burning Characteristics of Building Materials
BIFMA INTERNATIONAL (BIFMA)
ANSI/BIFMA M7.1 (2011; R 2016) Test Method for Determining VOC Emissions from Office Furniture Systems, Components and Seating
ANSI/BIFMA X5.1 (2017) American National Standards For Office Furnishings - General Purpose Office Chairs
ANSI/BIFMA X5.3 (2007; R2012) American National Standards For Office Furnishings - Vertical Files
ANSI/BIFMA X5.4 (2012) American National Standards For Office Furnishings - Lounge Seating
ANSI/BIFMA X5.5 (2014) American National Standards For Office Furnishings -Desk Products
ANSI/BIFMA X5.6 (2016) American National Standards For Office Furnishings -Panel Systems
ANSI/BIFMA X5.9 (2012) American National Standards For Office Furnishings - Storage Units
SECTION 12 59 00 Page 1
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)
NEMA WD 1 (1999; R 2015) Standard for General Color Requirements for Wiring Devices
NEMA WD 6 (2016) Wiring Devices Dimensions Specifications
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 101 (2018; TIA 18-1) Life Safety Code
NFPA 265 (2015) Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Coverings on Full Height Panels and Walls
NFPA 70 (2017; ERTA 1-2 2017; TIA 17-1; TIA 17-2;
TIA 17-3; TIA 17-4; TIA 17-5; TIA 17-6;
TIA 17-7; TIA 17-8; TIA 17-9; TIA 17-10;
TIA 17-11; TIA 17-12; TIA 17-13; TIA
17-14) National Electrical Code
SCIENTIFIC CERTIFICATION SYSTEMS (SCS)
SCS SCS Global Services (SCS)Indoor Advantage
TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA)
TIA-568-C.2 (2009; Errata 2010; Add 2 2014; Add 1 2016) Balanced Twisted-Pair Telecommunications Cabling and Components Standards
TIA-569 (2015d) Commercial Building Standard for Telecommunications Pathways and Spaces
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
UNDERWRITERS LABORATORIES (UL)
UL 1286 (2008; Reprint Feb 2015) Office Furnishings
UL 2818 (2013) GREENGUARD Certification Program For Chemical Emissions For Building Materials, Finishes And Furnishings
UL 723 (2008; Reprint Aug 2013) Test for Surface Burning Characteristics of Building Materials
1.2 DEFINITIONS
GFGI - Goverment Furnished, Government Installed.
SECTION 12 59 00 Page 2
1.3 COORDINATION
Manufacturer / supplier is to review and coordinate system funiture layout with electrical and telecommunications drawings. Report descrepencies and coorinate any required changes to the Project Manager and Architect prior to submittals and electrical installation.
1.4 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for Contractor Quality Control approval. Submit the following in accordance with Section 01 33 00
SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Detail Drawings; G
SD-03 Product Data
Warranty
Workstations
Power and Communications
Communications
SD-04 Samples
Workstations; G
Samples
SD-06 Test Reports
Selected Components
Panel Acoustics
Fire Safety
Electrical System; G
SD-07 Certificates
Workstations
Indoor Air Quality
SD-08 Manufacturer's Instructions
SD-10 Operation and Maintenance Data
Assembly Manuals
Maintenance Manuals; G
SECTION 12 59 00 Page 3
Cleaning
Electrical System; G
Installation
SD-11 Closeout Submittals
Energy Efficient Equipment
Reduced VOC's for Furniture
Recycled Content of Furniture
Bio-Based Content of Furniture
Indoor Air Quality for Office Furniture Systems and Seating
Recycled Content for system furniture components
1.5 CERTIFICATIONS
1.5.1 Indoor Air Quality Certifications
1.5.1.1 Office Furniture Systems and Seating
Provide products certified to meet indoor air quality requirements by UL 2818 (Greenguard) Gold, SCS Global Services Indoor Advantage Gold, ANSI/BIFMA M7.1 Certification or provide certification or validation by other third-party program that products meet the requirements of this Section. Provide current product certification documentation from certification body.
1.6 QUALITY ASSURANCE
1.6.1 General Safety
Provide workstation products free of rough or sharp edges.
1.6.2 Fire Safety
Components must meet requirements for flame spread and smoke development as specified by NFPA 101 except as follows. Conduct testing in accordance with either ASTM E84 or UL 723 on the entire assembled panel of the worst case (most combustible) combination of fabric and interior construction.
In addition, fabric must meet the requirements of NFPA 265 . Do not exceed 25 for Class A for panel flame spread and 450 for Class A, B and C panel smoke development.
1.6.3 Electrical System
The electrical system must meet the requirements of UL 1286 . Submit three sets of electrical system manuals describing the functions, configuration, and maintenance of the electrical system (power , communications, data). This material may be included in the Assembly or Maintenance manuals at the Contractor's option.
Manufacturer / supplier is to review and coordinate system funiture layout with electrical drawings.
SECTION 12 59 00 Page 4
1.6.4 Detail Drawings
Submit detail drawings showing communications, electronic data processing (EDP) and local area network (LAN); locations may be provided as a separate submittal from remaining workstation drawings. Provide drawing requirements, which are the furniture manufacturer's responsibility, as a single submittal. Provide electronic drawings to the user for future re-configuration in the software package requested by the user. Include in the electronic drawings all modifications made during installation. As a minimum, submit the following:
a. Overall reference drawings: Drawings showing workstation locations and overall plan view within each floor in a scale of 1/8 inch = 1 foot. Layouts must reflect field verified conditions and clearly illustrate the overall space planning concept and intent.
b. Installation drawings: Drawings showing workstations, panels, components, and plan view within each floor. Identify workstations by workstation type; submit drawings showing the proposed workstation installation at a scale of 1/4 inch = 1 foot, unless otherwise specified. Installation drawings must reflect field verified conditions.
c. Workstation elevations: Dimensioned workstation elevations showing each type of workstation with panel frame configurations and all components identified with manufacturer's catalog numbers. Draw elevations at 1/2 inch = 1 foot scale.
d. Panel drawings: Panel drawings showing locations and critical dimensions from finished face of walls, columns, panels, including clearances and aisle widths. Key assemblies to a legend which includes width, height, configuration and composition of frame covers finishes and fabrics (if different selections exist within a project), power or nonpower, connectors and wall mount hardware. Coordinate panel placement with location of electrical, voice/date LAN, SIPRNet, NIPERNet, mechanical and fire protection fixtures. Drawings must reflect field verified conditions.
e. Electrical drawings: Drawings showing power provisions including type and location of feeder components (service entry poles, base or ceiling feeds), activated power receptacles and other electrical components. Wiring configuration (circuiting, switching, internal and external connections) identified and a legend provided as applicable.
Identify which receptacles in typical furniture configurations will be connected to controlled building power circuits as applicable to meet ASHRAE 90.1 - IP ASHRAE 90.1 - SI requirements. Coordinate with electrical drawings.
f. Wire management capacity drawings.
g. Communication drawings showing telephone provisions: Drawings indicating the type and location of feeder components and communications jacks with wiring configuration identified where applicable.
h. Communication drawings showing electronic data processing provisions:
Drawings indicating the type and location of feeder components, communications jacks, or accessories with wiring configuration
SECTION 12 59 00 Page 5 identified where applicable.
i. Communication drawings showing local area network provisions:
Drawings indicating the type and location of feeder components and data jacks with extra ports for future expansion with wiring configuration identified where applicable.
j. Communications drawings indicating the TIA-568-C.2 pin/pair assignment that will be used for communications outlet as coordinated with the
COR.
k. Reflected ceiling plan for projects specified with power poles.
l. Drawings indicating cabling is protected at all transition points, and that metallic separation is provided between telecommunication and power wiring in the utility columns and systems furniture track in accordance with TIA-569 and NFPA 70 .
1.7 DELIVERY, STORAGE, AND HANDLING
Deliver components to the jobsite in the manufacturer's original packaging with the brand, item identification, and project reference clearly marked. Remove furniture from packaging and store in an unoccupied, dry location that is ventilated. Storage shall be free from dirt and dust, water, and other contaminants, and in a manner that permits easy access for inspection and handling.
1.8 WARRANTY
Warrant the systems furniture for a minimum period of 12 years with the following exceptions: fabrics and other covering materials, and paper handling products for 3 years, LED drivers/power supplies for 5 years, and electromagnetic ballasts for 3 years. Warranties must be signed by the authorized representative of the manufacturer. Present warranties, accompanied by document authenticating the signer as an authorized representative of the guarantor, to the Contracting Officer upon the completion of the project. Guarantee that the workstation products and installation are free from any defects in material and workmanship from the date of delivery. Submit two copies of the warranty.
PART 2 PRODUCTS
2.1 MATERIALS
Provide System Furniture Components with a minimum of 55 percent recycled content. Provide data identifying percentage of recycled content for system furniture components.
Provide certification of indoor air quality for Office Furniture Systems and Seating.
2.2 PRODUCT SUSTAINABILITY CRITERIA
For products in this section, where applicable and to extent allowed by performance criteria, provide and document the following:
2.2.1 Energy Efficient Equipment
Coordinate requirement for energy efficient equipment, such as lighting.
SECTION 12 59 00 Page 6
2.2.2 Reduced VOC's for Furniture
Coordinate requirement for reduced VOC requirements for furniture and provide documentation.
2.2.3 Recycled Content of Furniture
Coordinate requirement for recycled content for furniture and provide documentation.
2.1.4 Bio-Based Content of Furniture
Coordinate requirement for biobased content for furniture and provide documentation.
2.3 REFERENCE TO MANUFACTURER NAMES AND COLORS
Where product and color are shown as being specific to one manufacturer in the FF&E Package Attachment, an equivalent color or product by another manufacturer may be submitted for approval. Manufacturers, style lines, model numbers, finish, and fabric information are provided to establish design intent and are not intended to limit the selection of equal products and colors from other manufacturers.
2.4 FURNITURE PURCHASE
Purchase furniture, including checking accuracy of all acknowledgements and schedules from manufacturers and making necessary corrections to insure that the manufacturer has a correct understanding of the order and requirement. Provide furniture from the GSA Schedules and provide GSA pricing. Provide furniture from open market only when an item is not available on the GSA Schedules. See FAR clause 52.251-1 Government Supply Sources. The furniture provided needs to be available on the GSA Schedules to assist the User with future purchases. It is encouraged to solicit and provide GSA pricing on furniture. Compete the furniture purchase by obtaining a minimum of (3) separate proposals. Furniture is subject to FAR clause 52.236-5 Materials and Workmanship.
2.5 2.3 FURNITURE REQUIREMENTS
Use the FF&E Package Attachment in conjunction with the drawings and specifications for the furniture requirements. Provide furniture from manufacturer's standard product as shown in the most current published price list or amendment. Furniture provided must be part of current line as indicated with no intent to discontinue within two years. Provide furniture that is intended for commercial use not residential. Submit product data for all furniture items, to include catalog cuts, brochures, product information, and other necessary literature to indicate compliance with specifications. Provide product data for all items together in a single submittal When applicable, include GSA schedule information to confirm that items are available on GSA schedule. Tag product data sheets with applicable furniture item code and name. Submit data for all product style options for selection when options are available. This applies to but is not limited to furniture items that have options such as edge details, hardware options, and grommet colors. Submit manufacturer's certification stating that furniture meets these specifications.
SECTION 12 59 00 Page 7
2.5.1 Furniture Tests
1. Provide furniture that complies with the following testing requirements:
ANSI/BIFMA
1) Office Seating - ANSI/BIFMA X5.1
2) Vertical Files - ANSI/BIFMA X5.3
3) Lounge Seating - ANSI/BIFMA X5.4
4) Desk Products - ANSI/BIFMA X5.5
5) Panel Systems - ANSI/BIFMA X5.6
6) Storage - ANSI/BIFMA X5.9
2. Provide furniture with no rough or sharp edges or exposed connections. Clips, screws, and other construction elements must be concealed wherever possible.
3. Items such as desks, workstations and systems furniture must include all necessary components to be structurally sound and must not be attached to the wall unless specified to be wall mounted in the contract documents.
4. Desks, workstations, storage, and tables must have leveling devices to compensate for uneven floors.
5. The underside of desks, workstations, and tables must be completely and smoothly finished.
6. The backside of freestanding desks, workstations, and storage must be finished.
7. Provide chair casters and glides appropriate for the floor material they are located on, such as carpet and resilient flooring.
2.6 SYSTEM DESCRIPTION
2.6.1 Workstations
This specification establishes the minimum requirements for the acquisition and installation of a complete and usable system of workstations composed of panels, freestanding work surfaces or base units, supporting components, electrical hardware, communications, special electrical features, and accessories. Provide workstation requirements and configurations in accordance with the furniture layout and typical workstation types shown in drawings and specified herein. Provide components and hardware from a single manufacturer that are standard products as shown in the most recent published price lists or amendments.
Proposed product must be part of the manufacturer's current line with no intent to discontinue within two years. Submit complete listing of part/model numbers for all components to be provided, including names and codes of components referenced on updated drawings. Provide electrical components from a single manufacturer to the extent practicable (different types of components may be of different manufacturers, but all units of a given component must be from a single source). Conformance with NFPA 70 , UL 1286 , NFPA 101 , and 36 CFR 1191 is required. Coordinate the work of this section with that to be performed under other sections. This specification may include items which are not manufactured by the furniture manufacturer; provide any such items under this section. Submit two complete sets of certificates attesting that the proposed workstation meets specified requirements. Date the certificate after the award of the
SECTION 12 59 00 Page 8 contract, include the name of the project, and list specific requirements being certified.
2.6.2 Samples
Submit samples as required to obtain final approval. The Government reserves the right to reject any finish samples that do not satisfy the technical or color requirements. Work can not proceed without sample approval in writing from the Contracting Officer. Submit three sets of the finish samples listed below:
a. Panel, tackboard and overhead door fabric. Minimum 6 by 6 inches with label designating the manufacturer, pattern, color, fiber content, fabric width, fabric weight, fire rating, and use (panel and/or tackboard).
b. Workstation component finishes. Minimum 2-1/2 by 3 inches with label designating the manufacturer, material composition, thickness, color, and finish.
2.6.3 Alternate Design
Manufacturers who are unable to provide workstations that conform exactly to the furniture layouts and typical workstation types shown in the contract drawings, may submit alternate designs for consideration by the Contracting Officer. Alternate designs must meet or exceed the following criteria. Alternate designs that are submitted but do not meet these criteria will be rejected. In the alternate design provide workstations and components of the same basic size and configuration shown, with only the sizes of the individual components within the workstation changed to meet the standard product of the manufacturer or site conditions.
2.6.3.1 Filing and Storage Size and Configuration
The alternate design must provide filing and storage of the same basic size and configuration shown, with only the size changed to meet the standard product of the manufacturer. The storage capacity and interior clear dimensions must not be reduced.
2.6.3.2 Component Requirements
Provide the types of components or elements as shown on the drawings and as specified in PART 2 PRODUCTS of this specification. Do not reduce the storage capacity, number of workstations accommodated, width of aisles, or workstation configuration.
2.6.3.3 Wiring Configuration
Alternate configurations shall support the circuiting and connection capabilities identified under the provisions pertaining to power distribution of paragraph POWER AND COMMUNICATIONS. Generally any alternate will be acceptable which involves only a variation in size or quantity that exceeds the specified configuration.
2.6.4 Performance Requirements
Panels, frames and frame covers, connection system, work surfaces, pedestals, shelf units, overhead door cabinets, lateral files, locks, accessories, and miscellaneous hardware must meet testing as specified.
SECTION 12 59 00 Page 9
ISO 9001 certified manufacturers may perform in-house testing.
Manufacturers not ISO 9001 qualified will be required to produce testing by an independent testing laboratory. Component specific requirements are listed in appropriate paragraphs.
2.6.4.1 Selected Components
Workstation conformance to ANSI/BIFMA X5.5 and ANSI/BIFMA X5.6 is required with the following exceptions: Panels, or panel supported components conformance to ANSI/BIFMA X5.6 is required. Representative items will be selected for testing based on worst case situations (i.e., the deepest and widest work surface or shelf). Perform the keyboard drawer or shelf test applying a 50 lb load to the center of the keyboard shelf for a period of 5 minutes. Any loosening of attachments or damage to the operation of the drawer or shelf will be cause for rejection.
2.7 SYSTEMS FURNITURE
2.7.1 Panel System Components
Supply accessories and appurtenances for a completely finished panel assembly with the system. Provide a system capable of structurally supporting cantilevered work surfaces, shelves, files, overhead cabinets, and other components in the configurations shown on the drawings plus more than one fully loaded component per panel per side. Provide panels that are tackable. Segments will be field removable from both sides of the panel. Provide a spine wall system where electrical and data management will be easily accessible by removable wall covers that can be removed while workstation components are still attached. Cables must be laid in the system, not threaded through the frame. Provide a panel system that is available in a variety of nominal widths and heights as designated on the drawings. Measure heights from the finished floor to the top of the panel. Supply powered and nonpowered panels that are compatible in height. Coordinate panel heights with the HVAC and electrical designs.
Submit three sets of Assembly Manuals describing assembly and reconfiguration procedures.
2.7.2 Panel Finishes
Provide panels in the following options: tackable fabric, perforated metal.
Exposed panel trim to have a factory baked enamel or epoxy powder finish.
Provide each fabric-faced panel with a seamless width of fabric stretched over the entire face of the panel. The fabric color throughout the installation must be consistent. Curved panels may use adhesives on curved sections. Attach the fabric securely and continuously along the entire perimeter of the panel and allow for easy removal and replacement in the field (with the exception of curved panels). Fabric must be factory installed with panel fabric content. 2.7.3
Raceways Provide raceways and covers as an integral part of the panel whether powered or nonpowered. Magnet held base covers will not be accepted.
2.7.4 Leveling Glides
Provide precise alignment of adjacent panels and include leveling glides to compensate for uneven floors. Provide quantity and location of leveling glides as recommended by the manufacturer. A minimum 3/4 inch adjustment range is required.
SECTION 12 59 00 Page 10
2.7.5 Connection System
Provide connectors which accommodate a variety of configurations as indicated on the drawings to include: a straight line connection of 2 panels (180 degrees), corner connection of 2 panels (90 degrees), T connection of 3 panels (90 degrees), cross connection of 4 panels (all 90 degrees),. Provide tight connections with continuous visual and acoustical seals. Plastic, painted metal, fabric or wood finish connections are required to match system.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .