Attachment D_v.02.xlsx
XLSX spreadsheet 27 KB Posted
- Solicitation number
- W912PF25QA054
About this file
This is an Independent Government Cost Estimate (IGCE) for a consolidated operation and maintenance services contract for USAG-Italy (Solicitation W912PF25QA054). The detailed Excel spreadsheet breaks down cleaning and maintenance services for multiple facilities at Ederle and Del Din locations, covering base year and four option years. Services include maintenance of grease traps, lift stations, septic tanks, drainage systems, water depuration systems, rain water systems, and various specialized equipment cleaning and inspection tasks.
The IGCE is structured with line items for different facility types and specific maintenance activities, with 41 distinct service categories across two primary locations (Ederle and Del Din). While unit prices are currently listed as zero, the document indicates comprehensive coverage of infrastructure maintenance, including cleaning of manholes, drainage channels, car wash pits, water testing, and disposal of waste water. The document is prepared by Ugo Marchezzolo and reviewed by Giovanni Zanon from the Contract Management team, with contact emails and phone numbers provided. The estimate was developed independently by the government without seeking formal contractor proposals, using market surveys, previous project experiences, and pricing references.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
IGCE
| RC040025J Cleaning and maintenance of grease traps, rain water systems (OWS), emergency lift stations and water depuration systems at Vicenza Community, Italy | |||||
| DESCRIPTION | Q.TY | UNIT | UNIT PRICE (EUR) | TOTAL AMT (EUR) | |
| BASE YEAR | |||||
| 1 | EDERLE TYPE A Grease Traps as per Annex 1 and Para 5.2.1.1.1 of PWS | 24 | Each | € - 0 | |
| 2 | EDERLE TYPE B Grease Traps as per Annex 2 and Para 5.2.1.1.2 of PWS | 6 | Each | € - 0 | |
| 3 | EDERLE TYPE C Lift pumping stations/septic tank as per Annex 6 and Para 5.2.1.4.1 of PWS | 2 | Each | € - 0 | |
| 4 | EDERLE TYPE D Lift pumping stations/septic tank as per Annex 7 and Para 5.2.1.4.2 of PWS | 2 | Each | € - 0 | |
| 5 | EDERLE TYPE D1 Lift pumping stations/septic tank as per Annex 8 and Para 5.2.1.4.3 of PWS | 4 | Each | € - 0 | |
| 6 | EDERLE TYPE E Septic tank as per Annex 10 pag 1 and Para 5.2.1.4.3.2 of PWS | 2 | Each | € - 0 | |
| 7 | EDERLE TYPE E Septic tank as per Annex 10 pag 2 and Para 5.2.1.4.3.2 of PWS | 2 | Each | € - 0 | |
| 8 | EDERLE TYPE E Septic tank as per Annex 09 and Para 5.2.1.4.3.1 of PWS | 2 | Each | € - 0 | |
| 9 | EDERLE TYPE F Blow-down tank as per Annex 13 and Para 5.2.1.6.1 of PWS | 2 | Each | € - 0 | |
| 10 | EDERLE TYPE G Flushing of sewer line as per Annex 19-20-21-22 Para 5.2.1.7.1 of PWS | 12 | Each | € - 0 | |
| 11 | EDERLE TYPE I Heating trench sump pumps as per Annex 15 and Para5.2.1.8.1 of PWS | 2 | Each | € - 0 | |
| 12 | VILLAGGIO CDC TYPE L Grease Interceptors as per Annex 3 and Para 5.2.1.2.1 of PWS | 2 | Each | € - 0 | |
| 13 | EDERLE#4 DISOLEATORE (DSL) OWS as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | |
| 14 | EDERLE#1 DD-1000-1S Mod. 3036 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | |
| 15 | EDERLE#1 SAGIDEP ser VPP Mod. VPP25 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | |
| 16 | EDERLE#3 PASSAVANT COALISATOR CRB NG as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | |
| 17 | EDERLE#6 PASSAVANT COALISATOR-E NG 10 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | |
| 18 | EDERLE#7 PASSAVANT COALISATOR -E NG 20 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | |
| 19 | EDERLE#1 PASSAVANT ADSORPATOR-E KG6 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | |
| 20 | EDERLE#2 PASSAVANT ADSORPATOR -CR KG20 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | |
| 21 | EDERLE#4 PASSAVANT COALISATOR-CRB NG30 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | |
| 22 | EDERLE 1800 MC Cleaning of manholes as per Annex 16,17,18 and Para 5.2.2.1 of PWS | 2 | Each | € - 0 | |
| 23 | EDERLE 2800MT Cleaning of drainage lines as per Annex 19,20,21,22 and Para 5.2.2 .2 of PWS | 2 | Each | € - 0 | |
| 24 | EDERLE#4 Sand collector near ecobiox as per Para 5.2.4.1 of PWS | 2 | Each | € - 0 | |
| 25 | EDERLE#6 solid sedimentation settling tanks as per Para 5.2.2.1 of PWS | 2 | Each | € - 0 | |
| 26 | EDERLE#1 sedimentation settling tanks as per Para 5.2.2.1 of PWS | 2 | Each | € - 0 | |
| 27 | EDERLE Inspection and maintenance of water depuration system as per Annex 32 Para 5.2.4.1 of PWS | 2 | Each | € - 0 | |
| 28 | EDERLE 211 WR Cleaning central and lateral darinage channel with sand disposal Annex 29 Para 5.2.4.1.1.2 of PWS | 2 | Each | € - 0 | |
| 29 | EDERLE # 44C 44H Ceaning 2 pits manual car was Annex Annex 31 Para 5.2.4.1.3 | 1 | Each | € - 0 | |
| 30 | EDERLE Water testing and parameters inspection as per Annex 33 and Para 5.2.4.3 of PWS | 2 | Each | € - 0 | |
| GR TOTAL CLIN 0001 (EDERLE) | € - 0 | ||||
| 31 | DEL DIN TYPE M Grease interceptors as per Annex 4 and Para 5.2.1.3.1 of PWS | 24 | Each | € - 0 | |
| 32 | DEL DIN TYPE N Lift pumping stations as per Annex 11 and Para 5.2.1.5.1 of PWS | 2 | Each | € - 0 | |
| 33 | DEL DIN TYPE N1 Lift pumping stations as per Annex 12 and Para 5.2.1.5.2 of PWS | 4 | Each | € - 0 | |
| 34 | DEL DIN DWR01 Cleaning central darinage channel and underground tank with sand disposal Annex 30 Para 5.2.4.1.2 | 2 | Each | € - 0 | |
| 35 | DEL DIN Bldg IT212.55 External undergrround CEP Tank Annex 14 Para 5.2.1.6.2 | 1 | Each | € - 0 | |
| 36 | DEL DIN #5 GAZEBO-DEC 1600 AS as per Para 5.2.2 of PWS Annex 25 | 2 | Each | € - 0 | |
| 37 | DEL DIN #19 GAZEBO-DEO C 1200 AS as per Para 5.2.2 of PWS Annex 25 | 2 | Each | € - 0 | |
| 38 | DEL DIN rain tanks in VRC as per Para 5.2.2.4 of PWS Annex 25 | 2 | Each | € - 0 | |
| 39 | DEL DIN rain tanks in Polyethilene as per Para 5.2.2.4 of PWS Annex 25 | 2 | Each | € - 0 | |
| 40 | DEL DIN 580 cubic meter Disposal of waste rain water as per Para 5.2.2.4.1 of PWS annex 25 | 2 | Each | € - 0 | |
| 41 | DEL DIN Cleaning and inspection of lift stations Annex 26 as per Para 5.2.3.1 of PWS | 3 | Each | € - 0 | |
| GR. TOTAL CLIN 0002 (Del Din) | € - 0 | ||||
| 7500 | CMR | ||||
| GRAND TOTAL BASE YEAR | € - 0 | ||||
| OPTION YEAR ONE | |||||
| 1 | EDERLE TYPE A Grease Traps as per Annex 1 and Para 5.2.1.1.1 of PWS | 24 | Each | € - 0 | € - 0 |
| 2 | EDERLE TYPE B Grease Traps as per Annex 2 and Para 5.2.1.1.2 of PWS | 6 | Each | € - 0 | € - 0 |
| 3 | EDERLE TYPE C Lift pumping stations/septic tank as per Annex 6 and Para 5.2.1.4.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 4 | EDERLE TYPE D Lift pumping stations/septic tank as per Annex 7 and Para 5.2.1.4.2 of PWS | 2 | Each | € - 0 | € - 0 |
| 5 | EDERLE TYPE D1 Lift pumping stations/septic tank as per Annex 8 and Para 5.2.1.4.3 of PWS | 4 | Each | € - 0 | € - 0 |
| 6 | EDERLE TYPE E Septic tank as per Annex 10 pag 1 and Para 5.2.1.4.3.2 of PWS | 2 | Each | € - 0 | € - 0 |
| 7 | EDERLE TYPE E Septic tank as per Annex 10 pag 2 and Para 5.2.1.4.3.2 of PWS | 2 | Each | € - 0 | € - 0 |
| 8 | EDERLE TYPE E Septic tank as per Annex 09 and Para 5.2.1.4.3.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 9 | EDERLE TYPE F Blow-down tank as per Annex 13 and Para 5.2.1.6.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 10 | EDERLE TYPE G Flushing of sewer line as per Annex 19-20-21-22 Para 5.2.1.7.1 of PWS | 12 | Each | € - 0 | € - 0 |
| 11 | EDERLE TYPE I Heating trench sump pumps as per Annex 15 and Para5.2.1.8.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 12 | VILLAGGIO CDC TYPE L Grease Interceptors as per Annex 3 and Para 5.2.1.2.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 13 | EDERLE#4 DISOLEATORE (DSL) OWS as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 14 | EDERLE#1 DD-1000-1S Mod. 3036 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 15 | EDERLE#1 SAGIDEP ser VPP Mod. VPP25 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 16 | EDERLE#3 PASSAVANT COALISATOR CRB NG as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 17 | EDERLE#6 PASSAVANT COALISATOR-E NG 10 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 18 | EDERLE#7 PASSAVANT COALISATOR -E NG 20 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 19 | EDERLE#1 PASSAVANT ADSORPATOR-E KG6 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 20 | EDERLE#2 PASSAVANT ADSORPATOR -CR KG20 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 21 | EDERLE#4 PASSAVANT COALISATOR-CRB NG30 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 22 | EDERLE 1800 MC Cleaning of manholes as per Annex 16,17,18 and Para 5.2.2.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 23 | EDERLE 2800MT Cleaning of drainage lines as per Annex 19,20,21,22 and Para 5.2.2 .2 of PWS | 2 | Each | € - 0 | € - 0 |
| 24 | EDERLE#4 Sand collector near ecobiox as per Para 5.2.4.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 25 | EDERLE#6 solid sedimentation settling tanks as per Para 5.2.2.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 26 | EDERLE#1 sedimentation settling tanks as per Para 5.2.2.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 27 | EDERLE Inspection and maintenance of water depuration system as per Annex 32 Para 5.2.4.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 28 | EDERLE 211 WR Cleaning central and lateral darinage channel with sand disposal Annex 29 Para 5.2.4.1.1.2 of PWS | 2 | Each | € - 0 | € - 0 |
| 29 | EDERLE # 44C 44H Ceaning 2 pits manual car was Annex Annex 31 Para 5.2.4.1.3 | 1 | Each | € - 0 | € - 0 |
| 30 | EDERLE Water testing and parameters inspection as per Annex 33 and Para 5.2.4.3 of PWS | 2 | Each | € - 0 | € - 0 |
| GR TOTAL CLIN 0001 (EDERLE) | € - 0 | ||||
| 31 | DEL DIN TYPE M Grease interceptors as per Annex 4 and Para 5.2.1.3.1 of PWS | 24 | Each | € - 0 | € - 0 |
| 32 | DEL DIN TYPE N Lift pumping stations as per Annex 11 and Para 5.2.1.5.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 33 | DEL DIN TYPE N1 Lift pumping stations as per Annex 12 and Para 5.2.1.5.2 of PWS | 4 | Each | € - 0 | € - 0 |
| 34 | DEL DIN DWR01 Cleaning central darinage channel and underground tank with sand disposal Annex 30 Para 5.2.4.1.2 | 2 | Each | € - 0 | € - 0 |
| 35 | DEL DIN Bldg IT212.55 External undergrround CEP Tank Annex 14 Para 5.2.1.6.2 | 1 | Each | € - 0 | € - 0 |
| 36 | DEL DIN #5 GAZEBO-DEC 1600 AS as per Para 5.2.2 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 37 | DEL DIN #19 GAZEBO-DEO C 1200 AS as per Para 5.2.2 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 38 | DEL DIN rain tanks in VRC as per Para 5.2.2.4 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 39 | DEL DIN rain tanks in Polyethilene as per Para 5.2.2.4 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 40 | DEL DIN 580 cubic meter Disposal of waste rain water as per Para 5.2.2.4.1 of PWS annex 25 | 2 | Each | € - 0 | € - 0 |
| 41 | DEL DIN Cleaning and inspection of lift stations Annex 26 as per Para 5.2.3.1 of PWS | 3 | Each | € - 0 | € - 0 |
| GR. TOTAL CLIN 0002 (Del Din) | € - 0 | ||||
| 7500 | CMR | ||||
| GRAND TOTAL OPTION YEAR ONE | € - 0 | ||||
| OPTION YEAR TWO | |||||
| 1 | EDERLE TYPE A Grease Traps as per Annex 1 and Para 5.2.1.1.1 of PWS | 24 | Each | € - 0 | € - 0 |
| 2 | EDERLE TYPE B Grease Traps as per Annex 2 and Para 5.2.1.1.2 of PWS | 6 | Each | € - 0 | € - 0 |
| 3 | EDERLE TYPE C Lift pumping stations/septic tank as per Annex 6 and Para 5.2.1.4.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 4 | EDERLE TYPE D Lift pumping stations/septic tank as per Annex 7 and Para 5.2.1.4.2 of PWS | 2 | Each | € - 0 | € - 0 |
| 5 | EDERLE TYPE D1 Lift pumping stations/septic tank as per Annex 8 and Para 5.2.1.4.3 of PWS | 4 | Each | € - 0 | € - 0 |
| 6 | EDERLE TYPE E Septic tank as per Annex 10 pag 1 and Para 5.2.1.4.3.2 of PWS | 2 | Each | € - 0 | € - 0 |
| 7 | EDERLE TYPE E Septic tank as per Annex 10 pag 2 and Para 5.2.1.4.3.2 of PWS | 2 | Each | € - 0 | € - 0 |
| 8 | EDERLE TYPE E Septic tank as per Annex 09 and Para 5.2.1.4.3.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 9 | EDERLE TYPE F Blow-down tank as per Annex 13 and Para 5.2.1.6.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 10 | EDERLE TYPE G Flushing of sewer line as per Annex 19-20-21-22 Para 5.2.1.7.1 of PWS | 12 | Each | € - 0 | € - 0 |
| 11 | EDERLE TYPE I Heating trench sump pumps as per Annex 15 and Para5.2.1.8.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 12 | VILLAGGIO CDC TYPE L Grease Interceptors as per Annex 3 and Para 5.2.1.2.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 13 | EDERLE#4 DISOLEATORE (DSL) OWS as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 14 | EDERLE#1 DD-1000-1S Mod. 3036 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 15 | EDERLE#1 SAGIDEP ser VPP Mod. VPP25 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 16 | EDERLE#3 PASSAVANT COALISATOR CRB NG as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 17 | EDERLE#6 PASSAVANT COALISATOR-E NG 10 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 18 | EDERLE#7 PASSAVANT COALISATOR -E NG 20 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 19 | EDERLE#1 PASSAVANT ADSORPATOR-E KG6 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 20 | EDERLE#2 PASSAVANT ADSORPATOR -CR KG20 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 21 | EDERLE#4 PASSAVANT COALISATOR-CRB NG30 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 22 | EDERLE 1800 MC Cleaning of manholes as per Annex 16,17,18 and Para 5.2.2.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 23 | EDERLE 2800MT Cleaning of drainage lines as per Annex 19,20,21,22 and Para 5.2.2 .2 of PWS | 2 | Each | € - 0 | € - 0 |
| 24 | EDERLE#4 Sand collector near ecobiox as per Para 5.2.4.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 25 | EDERLE#6 solid sedimentation settling tanks as per Para 5.2.2.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 26 | EDERLE#1 sedimentation settling tanks as per Para 5.2.2.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 27 | EDERLE Inspection and maintenance of water depuration system as per Annex 32 Para 5.2.4.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 28 | EDERLE 211 WR Cleaning central and lateral darinage channel with sand disposal Annex 29 Para 5.2.4.1.1.2 of PWS | 2 | Each | € - 0 | € - 0 |
| 29 | EDERLE # 44C 44H Ceaning 2 pits manual car was Annex Annex 31 Para 5.2.4.1.3 | 1 | Each | € - 0 | € - 0 |
| 30 | EDERLE Water testing and parameters inspection as per Annex 33 and Para 5.2.4.3 of PWS | 2 | Each | € - 0 | € - 0 |
| GR TOTAL CLIN 0001 (EDERLE) | € - 0 | ||||
| 31 | DEL DIN TYPE M Grease interceptors as per Annex 4 and Para 5.2.1.3.1 of PWS | 24 | Each | € - 0 | € - 0 |
| 32 | DEL DIN TYPE N Lift pumping stations as per Annex 11 and Para 5.2.1.5.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 33 | DEL DIN TYPE N1 Lift pumping stations as per Annex 12 and Para 5.2.1.5.2 of PWS | 4 | Each | € - 0 | € - 0 |
| 34 | DEL DIN DWR01 Cleaning central darinage channel and underground tank with sand disposal Annex 30 Para 5.2.4.1.2 | 2 | Each | € - 0 | € - 0 |
| 35 | DEL DIN Bldg IT212.55 External undergrround CEP Tank Annex 14 Para 5.2.1.6.2 | 1 | Each | € - 0 | € - 0 |
| 36 | DEL DIN #5 GAZEBO-DEC 1600 AS as per Para 5.2.2 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 37 | DEL DIN #19 GAZEBO-DEO C 1200 AS as per Para 5.2.2 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 38 | DEL DIN rain tanks in VRC as per Para 5.2.2.4 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 39 | DEL DIN rain tanks in Polyethilene as per Para 5.2.2.4 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 40 | DEL DIN 580 cubic meter Disposal of waste rain water as per Para 5.2.2.4.1 of PWS annex 25 | 2 | Each | € - 0 | € - 0 |
| 41 | DEL DIN Cleaning and inspection of lift stations Annex 26 as per Para 5.2.3.1 of PWS | 3 | Each | € - 0 | € - 0 |
| GR. TOTAL CLIN 0002 (Del Din) | € - 0 | ||||
| 7500 | CMR | ||||
| GRAND TOTAL OPTION YEAR TWO | € - 0 | ||||
| OPTION YEAR THREE | |||||
| 1 | EDERLE TYPE A Grease Traps as per Annex 1 and Para 5.2.1.1.1 of PWS | 24 | Each | € - 0 | € - 0 |
| 2 | EDERLE TYPE B Grease Traps as per Annex 2 and Para 5.2.1.1.2 of PWS | 6 | Each | € - 0 | € - 0 |
| 3 | EDERLE TYPE C Lift pumping stations/septic tank as per Annex 6 and Para 5.2.1.4.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 4 | EDERLE TYPE D Lift pumping stations/septic tank as per Annex 7 and Para 5.2.1.4.2 of PWS | 2 | Each | € - 0 | € - 0 |
| 5 | EDERLE TYPE D1 Lift pumping stations/septic tank as per Annex 8 and Para 5.2.1.4.3 of PWS | 4 | Each | € - 0 | € - 0 |
| 6 | EDERLE TYPE E Septic tank as per Annex 10 pag 1 and Para 5.2.1.4.3.2 of PWS | 2 | Each | € - 0 | € - 0 |
| 7 | EDERLE TYPE E Septic tank as per Annex 10 pag 2 and Para 5.2.1.4.3.2 of PWS | 2 | Each | € - 0 | € - 0 |
| 8 | EDERLE TYPE E Septic tank as per Annex 09 and Para 5.2.1.4.3.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 9 | EDERLE TYPE F Blow-down tank as per Annex 13 and Para 5.2.1.6.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 10 | EDERLE TYPE G Flushing of sewer line as per Annex 19-20-21-22 Para 5.2.1.7.1 of PWS | 12 | Each | € - 0 | € - 0 |
| 11 | EDERLE TYPE I Heating trench sump pumps as per Annex 15 and Para5.2.1.8.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 12 | VILLAGGIO CDC TYPE L Grease Interceptors as per Annex 3 and Para 5.2.1.2.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 13 | EDERLE#4 DISOLEATORE (DSL) OWS as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 14 | EDERLE#1 DD-1000-1S Mod. 3036 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 15 | EDERLE#1 SAGIDEP ser VPP Mod. VPP25 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 16 | EDERLE#3 PASSAVANT COALISATOR CRB NG as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 17 | EDERLE#6 PASSAVANT COALISATOR-E NG 10 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 18 | EDERLE#7 PASSAVANT COALISATOR -E NG 20 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 19 | EDERLE#1 PASSAVANT ADSORPATOR-E KG6 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 20 | EDERLE#2 PASSAVANT ADSORPATOR -CR KG20 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 21 | EDERLE#4 PASSAVANT COALISATOR-CRB NG30 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 22 | EDERLE 1800 MC Cleaning of manholes as per Annex 16,17,18 and Para 5.2.2.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 23 | EDERLE 2800MT Cleaning of drainage lines as per Annex 19,20,21,22 and Para 5.2.2 .2 of PWS | 2 | Each | € - 0 | € - 0 |
| 24 | EDERLE#4 Sand collector near ecobiox as per Para 5.2.4.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 25 | EDERLE#6 solid sedimentation settling tanks as per Para 5.2.2.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 26 | EDERLE#1 sedimentation settling tanks as per Para 5.2.2.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 27 | EDERLE Inspection and maintenance of water depuration system as per Annex 32 Para 5.2.4.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 28 | EDERLE 211 WR Cleaning central and lateral darinage channel with sand disposal Annex 29 Para 5.2.4.1.1.2 of PWS | 2 | Each | € - 0 | € - 0 |
| 29 | EDERLE # 44C 44H Ceaning 2 pits manual car was Annex Annex 31 Para 5.2.4.1.3 | 1 | Each | € - 0 | € - 0 |
| 30 | EDERLE Water testing and parameters inspection as per Annex 33 and Para 5.2.4.3 of PWS | 2 | Each | € - 0 | € - 0 |
| GR TOTAL CLIN 0001 (EDERLE) | € - 0 | ||||
| 31 | DEL DIN TYPE M Grease interceptors as per Annex 4 and Para 5.2.1.3.1 of PWS | 24 | Each | € - 0 | € - 0 |
| 32 | DEL DIN TYPE N Lift pumping stations as per Annex 11 and Para 5.2.1.5.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 33 | DEL DIN TYPE N1 Lift pumping stations as per Annex 12 and Para 5.2.1.5.2 of PWS | 4 | Each | € - 0 | € - 0 |
| 34 | DEL DIN DWR01 Cleaning central darinage channel and underground tank with sand disposal Annex 30 Para 5.2.4.1.2 | 2 | Each | € - 0 | € - 0 |
| 35 | DEL DIN Bldg IT212.55 External undergrround CEP Tank Annex 14 Para 5.2.1.6.2 | 1 | Each | € - 0 | € - 0 |
| 36 | DEL DIN #5 GAZEBO-DEC 1600 AS as per Para 5.2.2 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 37 | DEL DIN #19 GAZEBO-DEO C 1200 AS as per Para 5.2.2 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 38 | DEL DIN rain tanks in VRC as per Para 5.2.2.4 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 39 | DEL DIN rain tanks in Polyethilene as per Para 5.2.2.4 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 40 | DEL DIN 580 cubic meter Disposal of waste rain water as per Para 5.2.2.4.1 of PWS annex 25 | 2 | Each | € - 0 | € - 0 |
| 41 | DEL DIN Cleaning and inspection of lift stations Annex 26 as per Para 5.2.3.1 of PWS | 3 | Each | € - 0 | € - 0 |
| GR. TOTAL CLIN 0002 (Del Din) | € - 0 | ||||
| 7500 | CMR | ||||
| GRAND TOTAL OPTION YEAR THREE | € - 0 | ||||
| OPTION YEAR FOUR | |||||
| 1 | EDERLE TYPE A Grease Traps as per Annex 1 and Para 5.2.1.1.1 of PWS | 24 | Each | € - 0 | € - 0 |
| 2 | EDERLE TYPE B Grease Traps as per Annex 2 and Para 5.2.1.1.2 of PWS | 6 | Each | € - 0 | € - 0 |
| 3 | EDERLE TYPE C Lift pumping stations/septic tank as per Annex 6 and Para 5.2.1.4.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 4 | EDERLE TYPE D Lift pumping stations/septic tank as per Annex 7 and Para 5.2.1.4.2 of PWS | 2 | Each | € - 0 | € - 0 |
| 5 | EDERLE TYPE D1 Lift pumping stations/septic tank as per Annex 8 and Para 5.2.1.4.3 of PWS | 4 | Each | € - 0 | € - 0 |
| 6 | EDERLE TYPE E Septic tank as per Annex 10 pag 1 and Para 5.2.1.4.3.2 of PWS | 2 | Each | € - 0 | € - 0 |
| 7 | EDERLE TYPE E Septic tank as per Annex 10 pag 2 and Para 5.2.1.4.3.2 of PWS | 2 | Each | € - 0 | € - 0 |
| 8 | EDERLE TYPE E Septic tank as per Annex 09 and Para 5.2.1.4.3.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 9 | EDERLE TYPE F Blow-down tank as per Annex 13 and Para 5.2.1.6.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 10 | EDERLE TYPE G Flushing of sewer line as per Annex 19-20-21-22 Para 5.2.1.7.1 of PWS | 12 | Each | € - 0 | € - 0 |
| 11 | EDERLE TYPE I Heating trench sump pumps as per Annex 15 and Para5.2.1.8.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 12 | VILLAGGIO CDC TYPE L Grease Interceptors as per Annex 3 and Para 5.2.1.2.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 13 | EDERLE#4 DISOLEATORE (DSL) OWS as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 14 | EDERLE#1 DD-1000-1S Mod. 3036 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 15 | EDERLE#1 SAGIDEP ser VPP Mod. VPP25 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 16 | EDERLE#3 PASSAVANT COALISATOR CRB NG as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 17 | EDERLE#6 PASSAVANT COALISATOR-E NG 10 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 18 | EDERLE#7 PASSAVANT COALISATOR -E NG 20 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 19 | EDERLE#1 PASSAVANT ADSORPATOR-E KG6 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 20 | EDERLE#2 PASSAVANT ADSORPATOR -CR KG20 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 21 | EDERLE#4 PASSAVANT COALISATOR-CRB NG30 as per Para 5.2.2.1 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 22 | EDERLE 1800 MC Cleaning of manholes as per Annex 16,17,18 and Para 5.2.2.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 23 | EDERLE 2800MT Cleaning of drainage lines as per Annex 19,20,21,22 and Para 5.2.2 .2 of PWS | 2 | Each | € - 0 | € - 0 |
| 24 | EDERLE#4 Sand collector near ecobiox as per Para 5.2.4.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 25 | EDERLE#6 solid sedimentation settling tanks as per Para 5.2.2.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 26 | EDERLE#1 sedimentation settling tanks as per Para 5.2.2.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 27 | EDERLE Inspection and maintenance of water depuration system as per Annex 32 Para 5.2.4.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 28 | EDERLE 211 WR Cleaning central and lateral darinage channel with sand disposal Annex 29 Para 5.2.4.1.1.2 of PWS | 2 | Each | € - 0 | € - 0 |
| 29 | EDERLE # 44C 44H Ceaning 2 pits manual car was Annex Annex 31 Para 5.2.4.1.3 | 1 | Each | € - 0 | € - 0 |
| 30 | EDERLE Water testing and parameters inspection as per Annex 33 and Para 5.2.4.3 of PWS | 2 | Each | € - 0 | € - 0 |
| GR TOTAL CLIN 0001 (EDERLE) | € - 0 | ||||
| 31 | DEL DIN TYPE M Grease interceptors as per Annex 4 and Para 5.2.1.3.1 of PWS | 24 | Each | € - 0 | € - 0 |
| 32 | DEL DIN TYPE N Lift pumping stations as per Annex 11 and Para 5.2.1.5.1 of PWS | 2 | Each | € - 0 | € - 0 |
| 33 | DEL DIN TYPE N1 Lift pumping stations as per Annex 12 and Para 5.2.1.5.2 of PWS | 4 | Each | € - 0 | € - 0 |
| 34 | DEL DIN DWR01 Cleaning central darinage channel and underground tank with sand disposal Annex 30 Para 5.2.4.1.2 | 2 | Each | € - 0 | € - 0 |
| 35 | DEL DIN Bldg IT212.55 External undergrround CEP Tank Annex 14 Para 5.2.1.6.2 | 1 | Each | € - 0 | € - 0 |
| 36 | DEL DIN #5 GAZEBO-DEC 1600 AS as per Para 5.2.2 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 37 | DEL DIN #19 GAZEBO-DEO C 1200 AS as per Para 5.2.2 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 38 | DEL DIN rain tanks in VRC as per Para 5.2.2.4 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 39 | DEL DIN rain tanks in Polyethilene as per Para 5.2.2.4 of PWS Annex 25 | 2 | Each | € - 0 | € - 0 |
| 40 | DEL DIN 580 cubic meter Disposal of waste rain water as per Para 5.2.2.4.1 of PWS annex 25 | 2 | Each | € - 0 | € - 0 |
| 41 | DEL DIN Cleaning and inspection of lift stations Annex 26 as per Para 5.2.3.1 of PWS | 3 | Each | € - 0 | € - 0 |
| GR. TOTAL CLIN 0002 (Del Din) | € - 0 | ||||
| 7500 | CMR | ||||
| GRAND TOTAL OPTION YEAR FOUR | € - 0 |
| BY | € - 0 |
| OY1 | € - 0 |
| OY2 | € - 0 |
| OY3 | € - 0 |
| OY4 | € - 0 |
GRAND TOTAL € - 0
signature
INDEPENDENT GOVERNMENT COST ESTIMATE
| PREPARED BY: | UGO MARCHEZZOLO | REVIEWED BY: | GIOVANN ZANON |
| CONTRACT MANAGEMENT SPECIALIST | CHIEF OF UTILITIES | ||
| ugo.marchezzolo2.ln@army.mil | giovanni.zanon.ln@army.mil | ||
| Phone Number : 646-2687 | Phone Number: 646-2684 |
Signature: Signature:
This IGCE was developed independently by the Government without seeking any formal proposals from contractors.For materials and equipment not available in the above price books the costs were based on market surveys.
Market surveys are a combination of previous experience with similar projects, Job Order Contract Price Book with contractor discounts, and/or suppliers/manufacturer quotes.
mailto:ugo.marchezzolo2.ln@army.milmailto:giovanni.zanon.ln@army.mil
File details come from the government source that posted it. Updated .