This document contains an asbestos testing report and a related federal contract opportunity notice. The asbestos testing report details results from samples taken at Mark Twain Lake, identifying asbestos in some cloth samples.

The federal contract opportunity notice is seeking firms to replace two excitation systems for hydropower generators at the Clarence Cannon Power Plant on Mark Twain Lake. The selected contractor will remove and properly abate asbestos-containing excitation cubicles and repair floors before installing new digital exciters, power potential transformers, and making other generator and control upgrades. The solicitation number is W912P919R0044 and is an unrestricted request for proposal with a contract duration of 18 months and estimated value between $1-5 million. The closing date for proposal submissions will be included in the solicitation package to be issued on or around July 19, 2019.

Asbestos Testing Report 391609384_001

View the file

Other files for this federal contract opportunity

Other files attached to Clarence Cannon Dam Excitation Replacement System, newest first.
File Type Posted
A22_W912P919R0044_Amend_6.pdf PDF
Unit_1_Test_Report.pdf PDF
Revised_Excitation_Specs.pdf PDF
A22_W912P919R0044_Amend_5.pdf PDF
Unit_2_Test_Report.pdf PDF
A22_W912P919R0044_Amend_4.pdf PDF
Pre-Bid_Sign-In.pdf PDF
A22_W912P919R0044_Amend_3.pdf PDF
20190812_CT_Cabinet_Photos.zip ZIP file
A22_W912P919R0044_Amend_2.pdf PDF
A22_W912P919R0044_Amend_1.pdf PDF
A02_CC_Excitation_Plans.pdf PDF
A02_CC_Excitation_Spec.pdf PDF
A02_CC_Excitation_Ref_Drawings.pdf PDF
A22_Sol_W912P919R0044_Clarence_Cannon_Dam_Excitation_Replacement_System.pdf PDF
A12_Synopsis_19R044.pdf PDF
Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EMSL Analytical, Inc.

3029 S. Jefferson Saint Louis, MO 63118

Tel/Fax: (314) 577-0150 / (314) 776-3313 http://www.EMSL.com / saintlouislab@emsl.com

391609384EMSL Order:

Customer ID: UACP25

Customer PO: JISA

Project ID:

Attention: Phone:Michael Henry (314) 623-0549

Fax:US Army Corps of Engineers

Received Date:Foot of Arsenal Street 10/03/2016 10:55 AM

Analysis Date:Saint Louis, MO 63118 10/04/2016

Collected Date:

Project: Mark Twain Lake

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

001-Cloth

391609384-0001

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

001-Cloth

391609384-0001A

39% ChrysotileNon-fibrous (Other)42%Fibrous (Other)19%Gray

Fibrous

Homogeneous

001-Cloth

391609384-0001B

None DetectedNon-fibrous (Other)51%Fibrous (Other)49%Brown

Non-Fibrous

Homogeneous

001-Cloth

391609384-0001C

69% ChrysotileNon-fibrous (Other)31%Gray

Fibrous

Homogeneous

Analyst(s)

Sue Ferrario (4) Jeff Siria, Laboratory Manager or Other Approved Signatory

EMSL maintains liability limited to cost of analysis . This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%

Samples analyzed by EMSL Analytical, Inc. Saint Louis, MO NVLAP Lab Code 200742-0

Initial report from: 10/04/2016 10:39:50

Page 1 of 1ASB_PLM_0008 - 1.71 Printed: 10/4/2016 9:39 AM

File details come from the government source that posted it. Updated .