W912P522B0009 TPlans_JPP_Sevent Points Sewer_RTA Amend02 2022-06-21.pdf

PDF 3 MB Posted

Attached to
JPP Seven Points Campground Sewer Rehab Project
Solicitation number
W912P522B0009
Issued by

About this file

This document provides details for a federal construction contract solicitation and opportunity. The solicitation seeks firms to construct the Seven Points Sanitary Sewer network in Nashville, Tennessee. The work includes minor clearing and grubbing, trench excavation, installation of force main and sewerline components, connection to existing networks, abandonment of pipes and septic tanks, construction of a wet well and pump vault, pump installation, backfilling, seeding and other incidental work. The contract value is between $500,000 and $1,000,000. The NAICS code is 237110 and it has been set aside 100% for total small businesses with a size standard of $39.5 million. The solicitation was issued by the U.S. Army Corps of Engineers Nashville District. The contractor must complete all construction and demobilize from the site by March 31, 2023.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P lo t T im e

P lo t D a te

F il e N a m e

T im e

D a te

F il e

C

D

E

F

G

H

J

K

13121110987654321

B

A SHEET ID

®of Engineers

US Army Corps

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

F

IL

E N

A M

E

P L

O T

S C

A L

E

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E M

A R

K D

E S

C R

IP

T

IO

N

D A

T E

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

S I Z

E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

IS

S

U E

D A

T E

X

X

X

X

X

X

X

X

GRAVEL DRIVE

GATE

A S

P H

A L T D

R

IV

E

G A T

E

TEMP

POLE

ELEC.

PANELUTILITY BOX

(UNKNOWN)

MANHOLE

TC-510.75

IE-506.43

MANHOLE

TC-508.42

IE-505.59

CATCH BASIN

TC-504.37

IE-INACCESSIBLE

WOODS

WOODS

FENCE

PUMP

STATION

MANHOLE

TC-505.27

IE-ABANDONED

CONTROL

POINT #4

O

HP8

"S

WOODS

WOODS

8"

8"

8" 8" 8"

8"

6"

6"

6"

6"

6"

6"

SIGN

507.85

HVCHECK TO CP4

507.90

CP4 NAIL TDOT

507.93

CP4 NAIL

S T E

W A

R T S F

E R

R Y P

IK

E

STEWARTS FERRY PIKE

26+00

545545

545545

20+50 21+00 21+50 22+00 22+50 23+00 23+50 24+00 24+50 25+00 25+50 26+00 26+50 27+00 27+50 28+00

E L

E V

A T

IO

N

E L

E V

A T

IO

N

STATION

S E

V E

N P

O

IN

T S

D A

Y U

S E

A R

E A

S T

O N

E S

R

IV

E R

T

E N

N E

S S

E E

J P

E R

C Y

P R

IE

S

T R

E S

E R

V O

IR

P

R O

J E

C T

C U

M B

E R

L A

N D

R

IV

E R

B A

S

IN

W

P

-2

-B -0

/7

/2

N A

S H

V

IL

L E

D

IS

T R

IC

T

W

P

-2

-X -X

X X

X

T H

A V

E N

U E

S O

U T

H

SHEET ID

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

N

A R

C H

E

C-104.1

G M

U

G E

O R

G E

U K

U

F C

M

WATER LINE

CROSSING UNDER

FOR SEWER MAIN

SEE DETAIL ON C502

EXISTING WATER LINE

P L

A N

P

R O

F

IL

E

FENCE

EXISTING

MUST BE MIN 24" FROM EXISTING GROUND

PROPOSED SANITARY FORCE MAIN

APPROXIMATE LOCATION OF

EXISTING SURFACE

WATERLINE

EXISTING

FORCE MAIN

3" HDPE

2793 LF

PROPOSED

OR TRENCH

DIRECTIONAL BORE

TRENCH

BORE OR

DIRECTIONAL

FLOW

M A

T C

H L

IN

E S

H E

E T C .1

SCALE IN FEET

040 40 80

J O

A N

N E

R T

R A

IC

O

F F

P

.E

READY TO ADVERTISE

N A

S H

V

IL

L E

T

N

-3

Q

-S P

S -C

-1

.d g n

Q5-SPS

WALL

CONCRETE

EXISTING

STATION.

CONNECTION TO THE EXISTING WET WELL, CLEAN OUT AND LIFT

9. THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS OF THE

BACK FILLING AND ACCORDING TO THIS STANDARD.

SECTIONS. ALL STREET CUTS MUST BE REPAIRED IMMEDIATELY AFTER

AND CEMENTITIOUS PATCHES MAY ONLY BE APPLIED TO CONCRETE

8. BITUMINOUS PATCHES MAY ONLY BE APPLIED TO ASPHALT SECTIONS

ASPHALT, CONTRACTOR MUST SUBMIT PROPOSED WORK PLAN.

7. IF BORING AND JACKING IS PREFERRED OVER REPLACING THE

ALL UTILITIES ON THE PROJECT.

PROJECT SITE. THE CONTRACTOR SHALL DETERMINE THE LOCATION OF

THOSE INDICATED ARE NOT NECESSARILY ALL WHICH MAY EXIST ON THE

UTILITIES INDICATED ON THE PLANS ARE APPROXIMATELY ONLY, AND

6. LOCATIONS OF THE EXISTING ABOVEGROUND AND UNDERGROUND

BE REPAIRED AT THE CONTRACTORS EXPENSE.

FENCE CAUSED BY THE CONTRACTOR'S OPERATIONS SHALL

WITHIN AND SURROUNDING THE WORK AREA. ANY DAMAGE TO THE

THE COR IMMEDIATELY IF ANY DAMAGE OCCURS TO THE FENCE

SHALL BE ACCEPTED BY THE COR. THE CONTRACTOR SHALL NOTIFY

SHALL BE PLACED BACK TOGETHER AND SECURED. THE FENCE REPAIR

FENCE. UPON COMPLETION OF WORK IN THESE AREAS, THE FENCE

LEAST 10 DAYS IN ADVANCE OF THE REQUIRED DATE OF OPENING THE

FOR WORK IN THE AREA. THE CONTRACTOR SHALL NOTIFY THE COR AT

WITHIN THE WORK AREA SHALL BE CUT AND ROLLED BACK TO ALLOW

STATION WILL REMAIN UNDISTURBED. WHEN NECESSARY, FENCES

5. UNLESS OTHERWISE INDICATED, FENCE AROUND THE EXISTING LIFT

ACCORDANCE TO SPECIFICATION 31 00 00

4. CONTRACTOR SHALL PLACE WIRE TRACING AND WARNING TAPE IN

STANDARDS.

TRAFFIC CONTROLS SHOULD BE IN ACCORDANCE TO MUTCD

TRENCHING THE ROADS UNLESS OTHERWISE DIRECTED BY THE COR.

3. CONTRACTOR SHALL MAINTAIN ONE LANE OF TRAFFIC WHEN

THRUST BLOCK DETAILS.

DIRECTION IN THE PRESSURIZED PIPE. REFER TO SHEET C-502 FOR

2. CONTRACTOR SHALL PROVIDE THRUST BLOCKS AT ANY CHANGE IN

ACCORDANCE TO SPECIFICATION 33 30 00 SECTION 3.2.2.1.

1. INSTALL SEWER LINES THAT CROSS EXISTING WATERLINES IN

NOTES:

ON C 503

CONNECTION DETAIL

SEE STANDARD

LIFT STATION

TIE INTO EXISTING

AMMENDMENT 01:

APPROXIMATELY 8'' THICK.

TO THE COR FOR THEIR FINAL APPROVAL. THE CONCRETE SECTION IS

CONTACTOR SHALL PROVIDE A CONCRETE DEMO PLAN FOR THAT AREA

WALL INORDER TO CONNECT TO THE EXISINT LIFT STATION. THE

10. THE CONTRACTOR WILL HAVE TO REMOVE A SECTION OF CONCRETE

A D

D E

D N

O T

E

R

E V

/2

/2

SHEET ID

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R

P U

M P

C O

N T

R O

L S

C H

E M

A T

IC

A

N D

C A

B

IN

E T

D E

T A

IL

L

IF

T S

T A

T

IO

N

A N

D

A

N

IT

A R

Y W

A S

T E

S Y

S T

E M

S E

V E

N P

O

IN

T S

D A

Y U

S E

A R

E A

S T

O N

E S

R

IV

E R

T

E N

N E

S S

E E

J P

E R

C Y

P R

IE

S

T R

E S

E R

V O

IR

P

R O

J E

C T

C U

M B

E R

L A

N D

R

IV

E R

B A

S

IN

W

P

-2

-B -0

/7

/2

N A

S H

V

IL

L E

D

IS

T R

IC

T

A R

C H

E

J O

A N

N E

R T

R A

IC

O

F F

P

.E

E-601

G A

C

G A

C

W

P

-2

-X

-X X

X X

N A

S H

V

IL

L E

T

N

-3

T H

A V

E N

U E

S O

U T

H

Q

-S P

S -E

-6

.d g n

READY TO ADVERTISE

R

CONTROL CABINET INNER DOOR LAYOUT

C O

N T

R O

L

P U

M P

N O

.2

P U

M P

N O

.1

CB 3 CB 2 CB 1

RR

RUN RUN

SEAL LEAKSEAL LEAK

A A

R R

SILENCE

ALARMALARM

TEST

HAZARDOUS AREA

NON-HAZARDOUS AREA

8 1

ISR 1

5 6 5 6

ISR 2

8 1 8 1

ISR 3

5 6 5 6

ISR 4

8 1

NX

X N

R

MTR. 2 OVER TEMP

R3

R3

HEAT SENSOR

MTR. 2

R2

HEAT SENSOR

MTR. 1

MTR. 1 OVER TEMP

R

R2

ALARM HORN

R6

R6

R6

SILENCE

ALARM

RED

ALARM LIGHT

STROBE

TEST

ALARM

ISR4

R5

R5

SEAL PROBES

MTR. 2

15 16

MTR. 2 SEAL FAIL

MTR. 1 SEAL FAIL

R

SEAL PROBES

MTR. 1

R4

R4

3 4

ISR3

R1

R1

ALTERNATOR

ALT

M2

OL2

PUMP 2 RUN

A

M2

R3

AUTO

OFF

HAND

R1

ALT

ISR2

M1

ISR1

4 3

HAND

OFF

AUTO

R2

PUMP 1 RUN

A

M1

OL1

CB-1 M1 OL1

L2L1G

ALARM LIGHT

ALARM HORN

(35 AMP )

MTR.

PUMP

MTR.

PUMP

1 2 3 4 5 6 7 8

(OFF )

LS-1

(LEAD ON )

LS-2

(LAG ON )

LS-3

(HIGH LEVEL )

LS-4

FLOAT SWITCHES (TYP. )

ELECTRIC CODE.

504 OF THE NATIONAL

ACCORDANCE WITH ARTICLE

OPPS (TYP. ) INSTALL IN

CUSTOMER SUPPLIED SEAL-

OVER TEMP

MTR 1.

OVER TEMP

MTR 2.

HAND AUTO

OFF

HAND AUTO

OFF

SCALE: NOT TO SCALE

5 HP

5 HP

(35 AMP )

CB-3 (10 AMP )

(10 AMP )

H4H1

3000 VA, 240/120V

X1 X2

HEATER

(300 WATT )(5 AMP )

CB-4

M1

M2

M2

M1

35 F.L.A.

35 F.L.A.

COMPLETE REQUIREMENTS.

FLOW MEASUREMENT PARAGRAPH IN SPECIFICATIONS 33 33 00 FOR

REMOTE MOUNTED SENSOR IS RATED FOR WET LOCATIONS. REFER TO

IN A CONCRETE VALVE BOX IN LINE WITH SEWER PIPING. ENSURE

ENCLOSURE ON CONTROL PANEL FRAME. SENSOR SHALL BE PLACED

MEASUREMENTS AND SHALL BE MOUNTED ON SEPARATE NEMA 3R

TRANSMITTER CALCULATES, RECORDS, AND DISPLAYS FLOW

7. FLOW METER TYPE SHALL UTILIZE ELECTROMAGNETIC SENSING.

AS SHOWN ON DRAWING SHEET E-602.

6. INSTALLER SHALL INSTALL NEW EQUIPMENT FOR THE SERVICE

BOTTOM OF THE PANEL.

5. ALL CONDUIT MUST BE ROUTED TO PENETRATE FROM THE

DIVISION 1 GROUP D LOCATIONS.

4. THE LEVEL SENSING SYSTEM SHALL BE RATED FOR CLASS 1

EQUIPMENT".

ELECTRICAL EQUIPMENT BEFORE OPENING DOOR OR SERVICING

3. PROVIDE A UL LISTED WARNING LABEL. "WARNING - LOCKOUT

VAC BEFORE CONNECTING CONTROL CIRCUIT.

2. INSTALLER MUST VERIFY THAT PHASE TO NEUTRAL IS 120

GROUND PER NEC.

1. PANEL GROUND TERMINAL MUST BE CONNECTED TO EARTH

NOTES:

240V - 1 PHASE - 60 HERTZ SERVICE (SEE NOTE 6 )

(50 AMP )

CB-2 M2 OL1

(50 AMP )

G

G

TO GENERATOR

GEN. RECEPTACLE

GEN. PLUG

DPDT

240V, 100A

SWITCH

TRANSFER

(50 AMP )

(50 AMP )

Q5-SPS

NX

SENSOR

AC

20 VA, 120 V

TRANSMITTER

SEE NOTE 7

FLOW METER

R

V

R

E V

IS

E

D N

O T

E

/2

/2

P lo t T im e

P lo t D a te

F il e N a m e

T im e

D a te

F il e

C

D

E

F

G

H

J

K

13121110987654321

B

A SHEET ID

®of Engineers

US Army Corps

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

F

IL

E N

A M

E

P L

O T

S C

A L

E

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E M

A R

K D

E S

C R

IP

T

IO

N

D A

T E

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

S I Z

E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

IS

S

U E

D A

T

C-104.1
E-601.1

File details come from the government source that posted it. Updated .