Amend 0003 W912P522B009 TPlans_JPP Seven Points Sewer_ RTA 2022-06-28.pdf
PDF 21 MB Posted
- Attached to
- JPP Seven Points Campground Sewer Rehab Project
- Solicitation number
- W912P522B0009
About this file
This document provides details of a federal contract opportunity for construction services. The U.S. Army Corps of Engineers, Nashville District, is soliciting fixed-price bids to construct the Seven Points Sanitary Sewer network in Nashville, Tennessee. The work includes minor clearing and grubbing, trench excavation, installation of sewer lines and related components, connection to existing infrastructure, abandonment of septic systems, construction of a wet well and pump vault, and site restoration including seeding and mulching. The estimated value of the contract is between $500,000 and $1,000,000. Bids are due under Solicitation Number W912P522B0009. The North American Industry Classification System (NAICS) code is 237110 and the size standard is $39.5 million. This is a 100% small business set-aside. The selected contractor must complete all work by March 31, 2023 to accommodate the seasonal closure of the adjacent campground.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GR
STEWARTS FERRY PIKE
X
X
X
X
X
WM
BATH
HOUSE
ASPHALT
PARKING
ASPHALT
PARKING
KENNEL
PAVILION
GR
TC
TC
TC
GR
GR
GR
GR
GR
PICNIC
TABLE
AREAS
S
ID
E W
A L
K
24"C M P
IE-509.79
IE-509.27
A S P
H A
LT
D
R
IV
E
CONC.
CONTROL
POINT #2
CONTROL
POINT #3
WOODS
WOODS
8"
6"
GRAVELBLDG.
STOR.
TANK
IE-525.70
D
IP
515.92
CP3 PK TDOT
515.97
HVCHECK 103
515.98
CP3 PK
532.14
CP2 PK TDOT
532.19
CP2 PK
S E
V E
N P
O
IN
T S
D A
Y U
S E
A R
E A
S T
O N
E S
R
IV
E R
T
E N
N E
S S
E E
J
P E
R C
Y P
R
IE
S T
R E
S E
R V
O
IR
P R
O J E
C T
C U
M B
E R
L A
N D
R
IV
E R
B A
S
IN
W
P
-2
-B -0
/7
/2
N A
S H
V
IL
L E
D
IS
T R
IC
T
W
P
-2
-X -X
X X
X
T H
A V
E N
U E
S O
U T
H
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
N
A R
C H
E
G M
U
G E
O R
G E
U K
U
F C
M
P L
A N
P
R O
F
IL
E
FORCE MAIN
3" HDPE
2793 LF
PROPOSED
OR TRENCH
DIRECTIONAL BORE
OR TRENCH
DIRECTIONAL BORE
MUST BE MIN 24" FROM EXISTING GROUND
PROPOSED SANITARY FORCE MAIN
APPROXIMATE LOCATION OF
EXISTING SURFACE
FLOW
MATCHLINE SEE SHEET C.102
EXISTING WATERLINE
UNDER WATER LINE
SEWER MAIN CROSSING
SEE DETAIL ON C502 FOR
EXISTING WATER LINE
SCALE IN FEET
040 40 80
SEPARATION
FORCE MAIN
SEE NOTE 20 REGARDING
READY TO ADVERTISE
N A
S H
V
IL
L E
T
N
-3
Q
-S P
S -C
-1
.d g n
LATERAL
SEWER
SANITARY
SCH. 40
NEW 4" PVC,
SEWER LATERAL
SANITARY
SCH. 40
NEW 4" PVC,
ATTENDENT RV
CONNECTION FROM
REPLACE EXISTING
SEE REFERENCE Q5-69^316
CAPPED WITH FLOWABLE FILL
TO BE ABANDONED AND
FIELD VERIFY
EXISTING SEPTIC TANK
APPROXIMATE LOCATION OF
ABANDON BUILDING.
LINES AROUND THE
FOR EXISTING WATER
SEE REFENCE Q5-69^317
FLOW METER
PROPOSED
Q5-SPS
TOPS WILL BE WELDED
FLOWABLE FILL
AND CAPPED WITH
TO BE ABANDONED
MANHOLE
SANITARY SEWER
EXISTING
TOPS WILL BE WELDED
FLOWABLE FILL
AND CAPPED WITH
TO BE ABANDONED
MANHOLE
SANITARY SEWER
EXISTING
FLOWABLE FILL
CAPPED WITH
OUTFALL
SANITARY SEWER
EXISTING
OUT LOCATION
Q5-69^301 FOR CLEAN
SEE REFERENCE SHEET
CLEAN OUT
FLOWABLE FILL AT
AND CAPPED WITH
TO BE ABANDONED
SEWER LATERAL
EXISTING SANITARY
TOPS WILL BE WELDED
FLOWABLE FILL
AND CAPPED WITH
TO BE ABANDONED
MANHOLE
SANITARY SEWER
LOCATION OF EXISTING
APPROXIMATE
THE CONTRACTOR SHALL USE MECHANICAL ROCK EXCAVATION EQUIPMENT .
IF THE CONTRACTOR ENCOUNTORS COMPETENT ROCK WHEN EXCAVATING FOR THE WET WELL
23. THE CONTRACTOR MAY ENCOUNTOR COMPETENT ROCK BELOW 5 FEET.
STATION CLEAN OUT FOR CORS APPROVAL.
22. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR THE CONNECTION TO THE COMFORT
CIVIL AND MECHANICAL DETAILS.
21. REFER TO REFERENCE SHEETS Q5-69^301, Q5-69^315, Q5-69^316, AND Q5-69^317 FOR
TANK
20. THE FORCE MAIN SHALL MAINTAIN A 10' HORIZONTAL BUFFER FROM THE ABANDON STORAGE
SUBMITTED TO THE COR.
SUCCESSFULLY EMPTIED, CLEANED, FILLED, AND PLUGGED. THE PHOTOS SHALL BE TO BEEN
OF THE SEPTIC SYSTEM AND HAVE THE OUTFALL CAPPED. THE CONTRACTOR SHALL TAKE PHOTOS
EMPTY, CLEAN ,AND FILL THE SEPTIC TANK WITH FLOW ABLE FILL 19. THE CONTRACTOR MUST
18. SEE SHEET E100, E601 ,E602 AND REFERENCE SHEET Q5-69^301 FOR ELECTRICAL DETAILS
17. THE CONTRACTOR SHALL REFER TO SPECIFICATION 01 11 00 REGARDING SCHEDULING
16. EXISTING SANITARY SEWER LATERAL WILL BE ABANDONED AND CAPPED WITH FLOW ABLE FILL.
IMMEDIATELY AFTER BACK FILLING.
PATCHES MAY ONLY BE APPLIED TO CONCRETE SECTIONS. ALL STREET CUTS MUST BE REPAIRED
15. BITUMINOUS PATCHES MAY ONLY BE APPLIED TO ASPHALT SECTIONS AND CEMENTITIOUS
SUBMIT PROPOSED WORK PLAN.
14. IF BORING AND JACKING IS PREFERRED OVER REPLACING THE ASPHALT, CONTRACTOR MUST
UTILITIES ON THE PROJECT.
MAY EXIST ON THE PROJECT SITE. THE CONTRACTOR SHALL DETERMINE THE LOCATION OF ALL
THE PLANS ARE APPROXIMATELY ONLY, AND THOSE INDICATED ARE NOT NECESSARILY ALL WHICH
13. LOCATIONS OF THE EXISTING ABOVEGROUND AND UNDERGROUND UTILITIES INDICATED ON
SPECIFICATION 31 00 00
12. CONTRACTOR SHALL PLACE WIRE TRACING AND WARNING TAPE IN ACCORDANCE TO
STANDARDS.
OTHERWISE DIRECTED BY THE COR. TRAFFIC CONTROLS SHOULD BE IN ACCORDANCE TO MUTCD
11. CONTRACTORS SHALL MAINTAIN ONE LANE OF TRAFFIC WHEN TRENCHING THE ROADS UNLESS
PRESSURIZED PIPE. REFER TO SHEET C-501 FOR THRUST BLOCK DETAILS.
10. CONTRACTOR SHALL PROVIDE THRUST BLOCKS AT ANY CHANGE IN DIRECTION IN THE
30 00 SECTION 3.2.2.1.
9. INSTALL SEWER LINES THAT CROSS EXISTING WATERLINES IN ACCORDANCE TO SPECIFICATION 33
PRODUCT DATA FOR APPROVAL.
8. PROVIDE LIFT- OUT RAIL SYSTEM FOR EACH PUMP FOR FAST AND EASY REMOVAL. SUBMIT
ON SHOP DRAWINGS FOR APPROVAL.
7. EXACT LEVELS FOR FLOAT SWITCHES SHALL BE DETERMINED BY THE CONTRACTOR AND SHOWN
OF WET TANKS.
6. PROVIDE SHOP DRAWINGS THAT SHOW EXACT ELEVATIONS FOR INLET AND OUT CONNECTIONS
GOVERNMENT APPROVAL.
SHOP DRAWINGS WITH ACTUAL DIMENSIONS AND LAYOUT OF THE TANKS AND COMPONENTS FOR
5. THIS DRAWING IS A TYPICAL LAYOUT FOR LIFT STATION LOCATION. CONTRACTOR SHALL SUBMIT
LABEL.
4. ALL ACCESS LIDS, VALVE BOX COVERS, CLEAN OUT COVERS, ETC. SHALL HAVE "SANITARY SEWER"
OTHER REQUIRED ACCESSORIES FOR ITS OPERATION AND INSTALLATION.
3. LIFT STATION WILL INCLUDE SUBMERSIBLE PUMPS, MOTOR, CONTROL, FLOAT SWITCHES, AND
OF TOTAL DYNAMIC HEAD AS A MINIMUM.
2. SELECTED PUMPS SHALL BE RATED 230V/60HZ/1PH. PUMP CAPACITY TO BE 65GPM @ 110 FEET
MANUFACTURER.
1. GRINDER PUMPs SHALL BE FEASIBLE FOR OPERATIONS AS RECOMMENDED BY THE PUMP
NOTES:
J O
A N
N E
R T
R A
IC
O
F F
P
.E
SEE DETAIL SHEET C501 FOR MORE DETAILS
GRINDER PUMP
TOP OF WET WELL TANK: 513.00
C-101
/0
/2
C H
A N
G E
D S
E W
E R
L A
T E
R A
L M
A T
E R
IA
L
R E
V
P lo t T im e
P lo t D a te
F il e N a m e
:5
:3
P
M
/2
/2 c u s e rs
\h e c e c p k \d o c u m e n ts
\p w
\c e lr n \d
\Q
-S
P S
-C -1
.d g n
C
D
E
F
G
H
J
K
13121110987654321
B
A SHEET ID
US Army Corps of Engineers
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
F
IL
E N
A M
E
P L
O T
S C
A L
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
S I Z
E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
545545
545545
0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00
E L
E V
A T
IO
N
E L
E V
A T
IO
N
STATION
S
V E
N P
O
IN
T S
D A
Y U
S E
A R
E A
S T
O N
E S
R
IV
E R
T
E N
N E
S S
E E
J P
E R
C Y
P R
IE
S
T R
E S
E R
V O
IR
P
R O
J E
C T
C U
M B
E R
L A
N D
R
IV
E R
B A
S
IN
W
P
-2
-B -0
N A
S H
V
IL
L E
D
IS
T R
IC
T
W
P
-2
-X -X
X X
X
T H
A V
E N
U E
S O
U T
H
SHEET ID
A R
C H
E
G M
U
G E
O R
G E
U K
U
S G
P
S
IT
E D
E T
A
IL
/7
/2
READY TO ADVERTISE
N A
S H
V
IL
L E
T
N
-3
Q
-S P
S -C
-5
.d g n
TYPICAL LIFT STATION - WET WELL TANK LAYOUT
CLEAN OUT(TYP. )
SEE NOTES 3 AND 4
& COVER WITH GASKET(TYP. )
FROM RISERS
SLOPE SURFACE AWAY
SPECIFICATION FOR COMPACTION REQUIREMENTS.
TANKS. SEE EXCAVATION AND BACKFILL
PLACEMENT FOUNDATION TYPICAL FOR ALL PLACED SEPTIC
COMPACT EXISTING SOIL(95% COMPACTION ) PRIOR TO
FOUNDATION
NEW COMPACTED 12" MINERAL AGGREGATE BASE
SEE NOTE 1
GRINDER PUMPS(TYP. )
PUMP OFF
LEAD PUMP ON
LAG PUMP ON
SEE NOTE 8
FLOAT SWITCHES (TYP.)
CONDUIT
ELECTRICAL
GATE VALVE(TYP. )
LIFT OUT CHAINS
CHECK VALVE(TYP. )
GUIDE RAIL
HIGH WATER ALARM
DETAIL ON VALVE BOXES
FOR NASHVILLE METRO STANDARD
SEE REFERENCE SHEET
VALVE BOX(TYP. )
SEWER
SANITARYINFLUENT PIPE
NOT TO SCALE
PLAN VIEW OF WET WELL TANK
f t
Q5-SPS
CL
INLET
CLEANOUT
GATE VALVE
CONDUIT
CABLE &
ELECTRICAL
WITH MIN. RATING PRESSURE OF 150 PSI.
SCH. 80 OR HDPE, DR 11
3" DIA. WYE (TYP.)
(TYP.)
VALVE
GATE
PUMP (TYP. OF 2)
VALVE (TYP.)
CHECK
ATTENDANCE RV
FROM EXISTING BATHROOM AND
PIPE INLET
WET WELL TANK
5000 GAL.
DETAIL C503
CONNECTION
SEE STANDARD
INFLUENT PIPE
FOR PIPE CONTINUATION.
SEE SHEET C-500
3" DIA. HDPE (DR-11) PIPE TO FLOWMETER
BEACON
HIGH LEVEL ALARM
PANEL W/
DUPLEX CONTROL
VALVE BOX
PRE-CAST CONCRETE
J O
A N
N E
R T
R A
IC
O
F F
P
.E
C-501
SHEET E301 FOR ELECTRICAL CONNECTIONS
10. SEE SHEET E100 ,E601 , E602 AND REFERENCE
/ PIPE REMOVAL.
PIPE, SCH. 40 WITH UNION CONNECTION TO EASE PUMP
9. DISCHARGE ASSEMBLY SHALL HAVE STAINLESS STEEL
FOR APPROVAL.
FAST AND EASY PUMP REMOVAL. SUBMIT PRODUCT DATA
8. PROVIDE GUIDE RAIL SYSTEM FOR EACH PUMP FOR
APPROVAL.
PROVIDE SHOP DRAWINGS TO THE CORS FOR THEIR
FOR AT MINIMUM OF 50 MINS. THE CONTRACTOR SHALL
FLOATS SHALL BE SET TO RUN FOR 10 MINS AND OFF
ON, LAG PUMP ON, AND HIGH WATER ALARM. THE PUMP
7. LEVELS FOR FLOAT SWITCH : PUMP OFF, LEAD PUMP
WET WELL TANK.
ELEVATIONS FOR INLET AND OUTLET CONNECTIONS OF
6. PROVIDE SHOP DRAWINGS THAT SHOW EXACT
TANK AND COMPONENTS FOR GOVERNMENT APPROVAL.
DRAWINGS WITH ACTUAL DIMENSIONS AND LAYOUT OF THE
STATION LOCATION. CONTRACTOR SHALL SUBMIT SHOP
5. THIS DRAWING IS A TYPICAL LAYOUT FOR LIFT
COVERS, ETC. SHALL HAVE "SANITARY SEWER" LABEL.
4. ALL ACCESS LIDS, VALVE BOX COVERS, CLEAN OUT
BE 30" (MIN. )FOR PUMP INSTALLATION AND REMOVAL.
3. RISER AND TANK ACCESS FOR WET WELL TANK SHALL
OPERATION AND INSTALLATION.
VALVES, AND OTHER REQUIRED ACCESSORIES FOR ITS
GRINDERS PUMPS, MOTORS, CONTROLS, FLOAT SWITCHES,
2. LIFT STATION WILL INCLUDE WET WELL TANK,
5 HP GRINDER PUMP
2 PLACED INSIDE THE WET WELL TANK.
PUMPS: 65 GPM, 110 FT TDH , 230V/60Hz/1ph
OPERATIONS.
1. GRINDER PUMPS SHALL BE ALTERNATED IN
NOTES:
R E
V
/0
/2
R E
M O
V E
D N
O T
E
P lo t T im e
P lo t D a te
F il e N a m e
:5
:2
P
M
/2
/2 c u s e rs
\h e c e c p k \d o c u m e n ts
\p w
\c e lr n \d
\Q
-S
P S
-C -5
.d g n
C
D
E
F
G
H
J
K
13121110987654321
B
A SHEET ID
US Army Corps of Engineers
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
F
IL
E N
A M
E
P L
O T
S C
A L
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
S I Z
E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T
| PLAN & PROFILE 1 |
| SITE DETAIL 1 |
File details come from the government source that posted it. Updated .