E-602.pdf
PDF 592 KB Posted
- Attached to
- Center Hill Medium Voltage Cable Replacement Federal contract opportunity
- Solicitation number
- W912P521B0007
About this file
This document contains a federal contract opportunity notice and related file. The U.S. Army Corps of Engineers, Nashville District, is soliciting firm fixed price proposals to remove and replace existing medium-voltage cables and associated equipment for four generating units at the Center Hill Power Plant in Lancaster, Tennessee. Work includes disassembling and removing old cables and installing new 15kV MV-105 cables and Class 1A terminations, as well as procuring and installing temporary feeders and cable tray systems. Offerors must also develop asbestos abatement and environmental mitigation plans. A site visit was tentatively scheduled for April 13, 2021, with requests to submit site visit forms in advance. Proposals are due by an unspecified date. The opportunity notice provides relevant project details, points of contact, and updates to the scheduled site visit date to aid offerors in developing responsive proposals for this requirements contract.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W912P521B0007 Bid Abstract page 2.pdf | ||
| W912P521B0007 Bid Abstract page 1.pdf | ||
| Center Hill Reference Photos - Amendment 002.pdf | ||
| E-502.pdf | ||
| W912P521B00070002 Amendment 2.pdf | ||
| W912P521B0007 TSpecs Amendment 0002.pdf | ||
| M-401.pdf | ||
| W912P521B00070001 Amendment 1.pdf | ||
| W912P521B0007 Site Visit SignIn.pdf | ||
| W912P521B0007 final.pdf | ||
| W912P521B0007 RTA TSpecs.pdf | ||
| W912P521B0007 RTA TPlans.pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LENGTH
RUN
COND
NO
VOLTAGE
OPR
CONDUIT
NUMBER SIZE LENGTH SIZE INS FROMFUNCTION TO ROUTING
REMARKS
CABLE DESCRIPTION
NUMBER
LENGTH
RUN
COND
NO
VOLTAGE
OPR
CONDUIT
NUMBER SIZE LENGTH SIZE INS FROMFUNCTION TO ROUTING
REMARKS
CABLE DESCRIPTION
NUMBER
S O
L
IC
IT
A
T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S I Z
E
S U
B M
IT
T
E D
B Y
D A
T E
C O
N T
R A
C T
N O
C
H E
C K
E D
B Y
D R
A W
N B
Y
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
D E
S
IG
N E
D B
Y
S I Z
E
S U
B M
IT
T
E D
B Y
C O
N T
R A
C T
N O
C
H E
C K
E D
B Y
D R
A W
N B
Y
IS
S
U E
D A
T E
SHEET ID
M E
D
IU
M V
O L
T A
G E
C A
B L
E R
E P
L A
C E
M E
N T
C A
N E
Y F
O R
K R
IV
E
R
C E
N T
E R
H
IL
L D
A M
X X
X X
X X
-X X
-X -X
X X
N A
S H
V
IL
L E
D
IS
T R
IC
T
P O
R T
L A
N D
O R
E G
O N
H Y
D R
O E
L E
C T
R
IC
D E
S
IG
N C
E N
T E
R
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
XXXXXXXX
XXXXXXXX
XXXXXXXX
W X
X X
X X
-X X
-X -X
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E
C
D
E
F
G
H
J
K
1312111098765432
®of Engineers
US Army Corps
F il e N a m e
P lo t D a te
P lo t T im e
T im e
D a te
F il e
B
A
58'
58'
166'
128'
158'
88'
30'
U1
U2
U3
76'
31'
32'
24'
T2
T3
TAP
10'
10'
10'
202'
24'
T4
76'
T1
FEEDER ISOMETRIC DIAGRAM
NTS
REFERENCE DRAWINGS:
CABLE SCHEDULE - REMOVAL
NTS
CABLE SCHEDULE - INSTALL
NTS
ALL LENGTHS ARE APPROXIMATE FOR BIDDING PURPOSES1.
GENERAL NOTES:
S M
IL
E
S P
.E
IN
S
T A
L L
A N
D S
C H
E D
U L
E
IS
O
M E
T R
IC
D
IA
G
R A
M
E-602
M G
U N
D R
U M
B S
C H
O F
IE
L
D
E -6
.d g n
E R
O G
E R
S
File details come from the government source that posted it. Updated .