Orientation.pdf
PDF 858 KB Posted
- Attached to
- Corrosion Control Equipment Federal contract opportunity
- Solicitation number
- W912JV-19-Q-7011
About this file
Drawing with Orientation.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SOW_Corrosion_Control_Equipment_2019_rev4.docx | DOCX document | |
| Q&A__2.docx | DOCX document | |
| Questions_and_answers.docx | DOCX document | |
| Kingsley_B3_Architectural_2_of_2.pdf | ||
| 181109_-_Mechanical_B3_Set.pdf | ||
| 181109_-_Electrical_B3_Set.pdf | ||
| Kingsley_B3_Plumbing_-_Stamped.pdf | ||
| SOW_Corrosion_Control_Equipment_2019_rev4.docx | DOCX document | |
| Kingsley_B3_Architectural_1_of_2.pdf | ||
| SOW_Corrosion_Control_Equipment_2019_rev3.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
H A
Z -W
A S
T E
S H
O P
S T
K
A
IR
L O
C K
M
IX
IN
G
R O
O M
H A
Z -M
A T
S
T O
R
R O
O M
B E
D
C
B
IN
E
T S
S P
IL
L K
IT
C
T K
C T
K
STENCIL
ROOM
BEAD BLAST BOOTH
(EQUIPMENT)
HEPA DUST
CONTROLLED AREA
PAINT BOOTH
(EQUIPMENT)
HUMIDITY TEMP
CONTROLLED
AREA
P E
N E
T R
A N
T L
IN
E
M A
G N
E T
IC
U
N
IT
OIL ANALYSIS
ROOM
FILM VIEWING
ROOM
FILM PROC
ROOM
X-RAY CR
X-RAY VAULT
ROOM
OFFICE
JOINT OIL
ANALYSIS UNIT
EQUIPMENT
ROOM
AIR LOCK
FIRE
PROTECTION
ROOM
INSPECTION
BAY
TRAINING /
BREAK ROOM
BEAD BOOTH
ROOM
A-301
A-201
A-202 2
A-2021
A-201
47'-11 5/8"
2'-8" 10'-0" 16'-0" 10'-0" 2'-0" 3'-4" 2'-0" 5'-4" 16'-0" 3'-4" 4'-0" 16'-0" 3'-4" 3'-4" 2'-8"
13'-10"10'-2"
8'-8"5'-2"
A-301
4'-8"6'-6"16'-2"6'-6"14'-1 5/8"8"3'-4"3'-4"6'-0"5'-2"6'-6"
C T
K C
T K
C T
K C
T K
MEN'S
WOMEN'S
MEN'S
LOCKER
ROOM
OFFICE 111
VEST.
VEST.
PPE CLEAN
ROOM/
CIRCULAT.
HALLWAY
WOMEN'S
LOCKER
ROOM
LAUNDRY
ROOM
JAN
HANGAR
A-301
PAINT MIXING
ROOM /
HAZ-MAT
STOR
A-3112
A-311
A-401
A-311
A-311
A-311
A-311
A-311
A-312
A-312
A-312
A-402
PAINT BOOTH
46'-0" 54'-0" 46'-0"
A
B
A
A
B
105A
107A
108A
B
A
A
103B
A
B
A
113A
114A
116A
117A
120A
119A
A
121A
A
A
120B
123D 123E 1
B
126A
127A 125B
125A
A
A-141
8'-0" 26'-8"
10'-0" 19'-4"
6'-8"
5'-1"
5'-4"
5'-4"
1'-9" 5'-4" 10'-0" 10'-0" 10'-0" 11'-8" 6'-4"
C L R
A-503
K
G
E
D
B
3 4 5 6 7 8
A-405 2
A-405
A-211 1
A-212
4.111
A L
IG
N
5'-4"
4.104
4.104
4.104
4.111
4.111
4.111
4.111
4.114
SA6
S
SA6
S
SA6
S
SA6
S
SA6
S
FA25
N
B
FA25
N
FA25
N
SA3
S
SA3
S
SA3
SA3
S
SA3
SA6
S
SA6
S
SA3
S
SA6
S
SA6
S
SA6
S
SA6
S
123A
C
B
4.104
4.104
4.104
4.104
4.104
4.104
4.104
4.104
C
127B
A-202 3
115A
STORAGE
A-211
A-2122
A-141
A-141
A-141
A-141
4.104
4.1044.104
4.104
4.104 4.1044.104
A-504
A-501
4.121
115B
19'-6" 25'-2"
ARCHITECTURAL PLAN GENERAL
NOTES:
1. SITE DATUM OF FINISHED FIRST FLOOR INDICATED ON CIVIL
SITE PLAN = ELEVATION 100'-0" ON STRUCTURAL DRAWINGS.
2. FIELD VERIFY ALL DIMENSIONS, BRING ANY DISCREPANCIES TO THE
ATTENTION OF THE ARCHITECT/ENGINEER FOR FINAL DECISION.
3. MASONRY OPENING DIMENSIONS ARE NOMINAL. CONTRACTOR TO
COORDINATE ACTUAL WINDOW AND DOOR OPENING REQUIRED FOR
INSTALLATION WITH WINDOW AND DOOR MANUFACTURER.
4. ALL DIMENSIONS GIVEN TO FACE OF GYPSUM BOARD, UNLESS NOTED
OTHERWISE.
5. PROVIDE FIRE-RETARDANT BLOCKING IN STUD WALLS FOR WALL MOUNTED
CABINETRY AND EQUIPMENT. VERIFY BLOCKING REQUIREMENTS WITH
MANUFACTURER AS NECESSARY FOR SUPPORT OF WALL MOUNTED
EQUIPMENT, FURNISHINGS, VERTICAL PIPING/CONDUIT/CABLE
TRAYS, GRAB BARS, TOILET ROOM ACCESSORIES/PARTITIONS, FIRE
EXTINGUISHERS, WATER COOLERS AND OTHER WALL MOUNTED ITEMS.
6. FURNITURE SHOWN FOR REFERENCE ONLY, NIC.
7. PROVIDE LEAD LINED DRYWALL FOR CEILING AND WALLS AND LEAD LINED
DOORS AND FRAMES IN ROOM 104 - X-RAY VAULT ROOM.
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead & Hunt, Inc.
9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com www.tetratech.com
711 TANK FARM ROAD, SUITE 110
SAN LUIS OBISPO, CA 93401
PHONE: (805) 542-9052 FAX: (805) 542-9254
/1
/2
:4
:5
A
M C
R e vi t L o c a l\
-1
.0
-A
-C E
N T
R A
L -2 m m w
.r v t
A-101
FLOOR PLANS
O R
A N
G
K in g s le y F ie ld
K la m a th
F a lls
O
R
C O
N S
T R
U C
T C
O R
R O
S
IO
N C
O N
T R
O L H
A N
G A
R
NOT FOR CONSTRUCTION
3142200-121252.01
MW
SW
01/15/18
PM/MW
1/8" = 1'-0"1
FIRST FLOOR PLAN
KEYED NOTES
4.104 PRE-FINISHED METAL DOWNSPOUT, TYP
4.111 8" CMU WALL
4.114 REVOLVING DOOR
4.121 BOOTHS SUPPORT EQUIPMENT, NIC
01/15/18 B-1 SUBMISSION
BEAD BLAST BOOTH EQUIPEMENT WILL BE
LOCATED ON THE WEST EXTERIOR WALL
OF THE NEW CORROSION CONTROL
FACILITY
N
S
EW
1077433704N Highlight
1077433704N Highlight
1077433704N Highlight
1077433704N Highlight
1077433704N Highlight
1077433704N Line
1077433704N Highlight
1077433704N Line
1077433704N Line
1077433704N Line
1077433704N Line
First Floor
100'-0"
MECH SPACE
112'-0"
X-RAY VAULT
ROOM
INSPECTION
BAY
BEAD BOOTH
ROOM
A-301
FIRE
PROTECTION
ROOM
STENCIL
ROOM
T.O. WALL
142'-0"
PMB Eave Height
134'-0"
9 345678
PAINT BOOTH
MECH SPACE
HALLWAY
AIR LOCK
25'-2" 19'-6"
First Floor
100'-0"
MECH SPACE
112'-0"
A-3011
A-301
TRAINING /
BREAK ROOM
MEN'S
LOCKER
ROOM
PPE CLEAN
ROOM/
CIRCULAT.
HANGAR
A-312
H E
IG
H
T C
L E
A R
A N
C E
M
IN
PMB Eave Height
134'-0"
32'-4"
K G E D B
MECH SPACE
First Floor
100'-0"
A-301
HANGAR
T.O. WALL
142'-0"
PMB Eave Height
134'-0"
345678
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead & Hunt, Inc.
9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com www.tetratech.com
711 TANK FARM ROAD, SUITE 110
SAN LUIS OBISPO, CA 93401
PHONE: (805) 542-9052 FAX: (805) 542-9254
/1
/2
:4
:0
A
M C
R e vi t L o c a l\
-1
.0
-A
-C E
N T
R A
L -2 m m w
.r v t
A-301
BUILDING SECTIONS
O R
A N
G
K in g s le y F ie ld
K la m a th
F a lls
O
R
C O
N S
T R
U C
T C
O R
R O
S
IO
N C
O N
T R
O L H
A N
G A
R
NOT FOR CONSTRUCTION
3142200-121252.01
MW
SW
01/15/18
PM/MW
1/8" = 1'-0"1
BUILDING SECTION
1/8" = 1'-0"2
BUILDING SECTION
1/8" = 1'-0"3
BUILDING SECTION
01/15/18 B-1 SUBMISSION