Civil_Plan_Sheet_C-102_REV1.pdf

PDF 1 MB Posted

Attached to
Construct Air National Guard C-130 Squadron Operations Facility Federal contract opportunity
Solicitation number
W912JM16R0003
Issued by
Department of the Army Georgia Army National Guard

About this file

Civil Plan Sheet - C-102_Revision 1

View the file

Other files for this federal contract opportunity

Other files attached to Construct Air National Guard C-130 Squadron Operations Facility, newest first.
File Type Posted
W912JM-16-R-0003-0007_Solicitation_Amendment.pdf PDF
Specifications_Table_of_Contents_and_Appendices_Page_1_(R1)_-_26_May_2016.pdf PDF
Specification_Section_01_45_00.00_10_Quality_Control_(R1)_-__26_May_2016.pdf PDF
Specification_Section_01_33_00_10_Submittal_Procedures_(R1)_-__26_May_2016.pdf PDF
W912JM-16-R-0003-0006_Solicitation_Amendment.pdf PDF
Specification_Section_01_32_01.00_10_Project_Schedule_(R2)_-__26_May_2016.pdf PDF
J A_Brand_Name_Redacted.pdf PDF
W912JM-16-R-0003-0005_Solicitation_Amendment.pdf PDF
W912JM-16-R-0003-0004_Solicitation_Amendment.pdf PDF
Questions_and_Answers_-_25_May_2016.pdf PDF
W912JM-16-R-0003-0003_Solicitation_Amendment.pdf PDF
Questions_and_Answers_-_20_May_2016.pdf PDF
Civil_Plan_Sheet_C-103_REV1.pdf PDF
Specification_Section_01_32_01.00_10_Project_Schedule_(R1)_-__16_May_2016.pdf PDF
Civil_Plan_Sheet_C-101_REV1.pdf PDF
Questions_and_Answers_-_19_May_2016.pdf PDF
W912JM-16-R-0003-0002_Solicitation_Amendment.pdf PDF
W912JM-16-R-0003-0001_Solicitation_Amendment.pdf PDF
Pre-Proposal_Conference_PPT_Presentation_3MAY2016.pdf PDF
Report_of_Asbestos_and_Lead-Based_Paint_Survey.pdf PDF
Pre-Proposal_Conference_Attendees_3MAY2016.pdf PDF
Exhibits_A_-_D.docx DOCX document
W912JM-16-R-0003_Solicitation.pdf PDF
Synopsis_C-130_Squadron_Operations_Facility.pdf PDF
Show all 24

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

10-PZ-02

1 2 3 4 5

A

B

C

D

D W

N

B

Y

C K

D

B

Y

S U

B M

I T

T E

D

B

Y

D A

T E

A P

P R

D

A T

E D

E S

C R

I P

T I O

N M

A R

K A

P P

R

D A

T E

D E

S C

R I P

T I O

N M

A R

K

SHEET

IDENTIFICATION

SHEET OF

D E

S I G

N E

D

B

Y

F I L

E

N

A M

E

P a r k w a y

L a n e

S u i t e

N o r c r o s s

G

A

P h o n e

F a x

PL

OT

S

CA

LE

P L

O T

D

A T

E

S I Z

E

A N

S I

D

S O

L I C

I T

A T

I O

N

N

O

C O

N T

R A

C

N

F I L

E

N

O

Copyright © 2016 by Pond & Company.

All rights reserved. No copying or duplication of these documents is allowed without the express written agreement of Pond & Company.

M N a t i o n a l

G u a r d

B u r e a u

P r o j e c t s

G

A

A

G e w

S q u a d p s

B l d g

S

A V

C

A D

B

I M

C

A D

C d w g

A s i n d i c a t e d

G E

O R

G I

I R

T

I O

N A

L

G

U A

R D

S A

V A

N N

A H

G

E O

R G

I A

X D

Q U

C

Q U

A D

R O

N

O

P E

R A

T I O

F

C

I L

I T

Y

S A

V A

N N

A H

H

I L

T O

N

H

E A

D

I A

P

G

E O

R G

I A

P R

O J E

C

U M

B E

R

X

D Q

U

J O

B

N

O

TYPE B-3 SUBMITTAL

DEMOLITION PLAN

1"=30'

LIMITS OF DISTURBANCE

DEMOLISH CONCRETE

DEMOLISH BUILDING

DEMOLISH ASPHALT

ASPHALT PATCH

(SEE DETAIL C2/C-501)

DEMOLISH UTILITY LINE

DEMOLISH STRUCTURE

DEMOLISH STRUCTURE

MONITORING WELL

GEOTECH TEST LOCATION

SHEET LEGEND

SCALE: 1" = 30'

30 30 60

K D

H E

M I

J A

S

D E

M O

L I T

I O

N

P

L A

N

C-102

ROBERT B. M

ILLER DR.

BLAND BLVD.

BLAND BLVD.

D R

W

DEMOLISH EXISTING

BARRIER CONSISTING OF

STEEL POLES, CHAIN AND

JERSEY BARRIERS

(APPROXIMATE LOCATION)

CLEAR AND

GRUB EXISTING

VEGETATION (TYP)

FIRE HYDRANT "G"

TO BE DEMOLISHED

FIRE HYDRANT "F" TO BE RELOCATED

(SEE SHEET C-105)

DEMOLISH

BUILDING 1914

DEMOLISH

ASPHALT

PAVEMENT

STORM LINE

LOCATION FROM GIS

EXISTING CONCRETE

PAVEMENT TO REMAIN

EXISTING CONCRETE

PAVEMENT TO REMAIN

EXISTING CONCRETE

PAVEMENT TO REMAIN

DEMOLISH EXISTING

ASPHALT PAVEMENT

1. SEE SHEET C-001 FOR LEGEND AND ABBREVIATIONS

2. SEE SHEET C-002 FOR GENERAL NOTES

3. SEE ELECTRICAL PLANS FOR ELECTRICAL DEMOLITION.

4. PROTECT ALL EXISTING FEATURES NOT SHOWN FOR

DEMOLITION.

5. DEMOLISH VEGETATION WITHIN LIMITS OF DISTURBANCE.

6. SAWCUT ALL PAVEMENT TO BE DEMOLISHED.

7. SEE PROJECT SPECIFICATIONS FOR ASBESTOS

ABATEMENT.

8. LAYOUT ALL NEW PAVEMENT CUTS IN AREAS OF EXISTING

MONITORING WELLS FOR APPROVAL BY THE BASE.

SHEET NOTES

SHEET KEYNOTES

1. DEMOLISH WATER VALVE

2. DEMOLISH 6" WATER LINE. COORDINATE LIMITS WITH

UTILITY PLAN ON SHEET C-105.

3. DEMOLISH STORM DRAINAGE STRUCTURE

4. DEMOLISH STORM DRAINAGE LINE. COORDINATE

LENGTH WITH GRADING PLAN.

5. DEMOLISH BOLLARDS

6. DEMOLISH ASPHALT PAVEMENT

7. DEMOLISH CONCRETE PAVEMENT

8. DEMOLISH SANITARY SEWER LINE, SIZE UNKNOWN.

PLUG WYE CONNECTION AT MAIN.

9. DEMOLISH GAS LINE, SIZE UNKNOWN. COORDINATE

LIMITS WITH UTILITY PLAN ON SHEET C-105.

10. DEMOLISH SIGN

11. DEMOLISH MONITORING WELL. FOLLOW THE GEORGIA

ENVIRONMENTAL PROTECTION DIVISION WATER WELL

STANDARD ACT PROCEDURE AND PROVIDE THE

GOVERNMENT COPIES OF THE WELL ABANDONMENT

REPORT.

12. NOT USED

13. DEMOLISH WATER STUB OUT AND VALVE.

14. NOT USED

15. DEMOLISH WATER LINE. APPARENT 2" SIZE PER G.I.S.

SEE SHEET C-105 FOR NEW WATER LINE.

16. DEMOLISH WATER LINE. 10" TRANSITE FROM RECORDS.

17. PROVIDE CURB CUT FOR SLIDING SECURITY GATE. SEE

SHEET C-103.

18. PROTECT EXISTING CURB. SAWCUT PAVEMENT AT

EDGE OF CURB

19. SAWCUT AND DEMOLISH CONCRETE PAVEMENT FOR

SITE LIGHTING. PROVIDE CONCRETE PAVEMENT

PATCH, SEE DETAIL A3/C-506

20. SAWCUT AND DEMOLISH ASPHALT PAVEMENT FOR

SITE LIGHTING AND OTHER UTILITIES. PROVIDE

ASPHALT PAVEMENT PATCH, SEE DETAIL C2/C-501

21. PROVIDE TEMPORARY FENCING TO SEPARATE

CONSTRUCTION ACTIVITIES FROM APRON AND

IMPLEMENT FOREIGN OBJECT DEBRIS (FOD) CONTROL

PROCEDURES TO KEEP FOD OFF THE APRON. FENCING

PLACED ON TOP OF RAMP PAVEMENT SHALL BE

FREESTANDING WITH WEIGHTED LEGS. FENCING

SHALL NOT BE ANCHORED TO PAVEMENT.

22. REPLACE EXISTING 8" SANITARY SEWER PIPING WITH

8" DUCTILE IRON PIPE. COORDINATE SEWER OUTAGES

WITH BASE SO OUTAGES ONLY OCCUR LATE AT NIGHT

OR ON WEEKENDS.

23. DEMOLISH CURB

DEMOLISH

BUILDING 1907

PROTECT LIGHT POLE AND

CIRCUIT TO REMAIN

(REFERENCE PROJECT REPAIR

RAMP AREA IV - XDQU 072004)

DEMOLISH EXISTING

SIDEWALK

EXISTING STRIPING TO

BE ERADICATED

EX REMEDIATION WELLS TO REMAIN ( DO NOT

DISTURB BELOW GROUND ENVIRONMENTAL

REMEDIATION INFRASTRUCTURE)

10-MW-01S

DO NOT DISTURB

EX. MONITORING

WELL 10-MW-02S

DO NOT DISTURB

EX. MONITORING

WELL 08-MW-21

(ADJUST TOP TO

FINISHED GRADE)

DO NOT DISTURB

EX. MONITORING

WELLS TO REMAIN

DO NOT DISTURB EX. MONITORING

WELLS TO REMAIN IN THIS AREA

DO NOT DISTURB

EX. MONITORING

WELLS TO REMAIN

IN THIS AREA

M A

R K

D E

S C

R I P

T I O

N D

A T

E

File details come from the government source that posted it. Updated .