Civil_Plan_Sheet_C-101_REV1.pdf
PDF 1 MB Posted
- Attached to
- Construct Air National Guard C-130 Squadron Operations Facility Federal contract opportunity
- Solicitation number
- W912JM16R0003
About this file
Civil Plan Sheet - C-101_Revision 1
View the file
Other files for this federal contract opportunity
Show all 24
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 3 4 5
A
B
C
D
D W
N
B
Y
C K
D
B
Y
S U
B M
I T
T E
D
B
Y
D A
T E
A P
P R
D
A T
E D
E S
C R
I P
T I O
N M
A R
K A
P P
R
D A
T E
D E
S C
R I P
T I O
N M
A R
K
SHEET
IDENTIFICATION
SHEET OF
D E
S I G
N E
D
B
Y
F I L
E
N
A M
E
P a r k w a y
L a n e
S u i t e
N o r c r o s s
G
A
P h o n e
F a x
PL
OT
S
CA
LE
P L
O T
D
T
E
S I Z
E
A N
S I
D
S O
L I C
I T
A T
I O
N
N
O
C O
N T
R A
C
N
F I L
E
N
O
Copyright © 2016 by Pond & Company.
All rights reserved. No copying or duplication of these documents is allowed without the express written agreement of Pond & Company.
M N a t i o n a l
G u a r d
B u r e a u
P r o j e c t s
G
A
A
G e w
S q u a d p s
B l d g
S
A V
C
A D
B
I M
C
A D
C d w g
A s i n d i c a t e d
G E
O R
G I
I R
T
I O
N A
L
G
U A
R D
S A
V A
N N
A H
G
E O
R G
I A
X D
Q U
C
Q U
A D
R O
N
O
P E
R A
T I O
F
C
I L
I T
Y
S A
V A
N N
A H
H
I L
T O
N
H
E A
D
I A
P
G
E O
R G
I A
P R
O J E
C
U M
B E
R
X
D Q
U
J O
B
N
O
TYPE B-3 SUBMITTAL
EXISTING CONDITIONS PLAN
1"=30'
SHEET LEGEND
SCALE: 1" = 30'
30 30 60
K D
H E
M I
J A
S
E X
I S
T I N
G
C
O N
D I T
I O
P
L A
N
C-101
D R
W
LIMITS OF ADJACENT RAMP CONSTRUCTION
(REPAIR RAMP AREA IV - XDQU 072004) CONCRETE
REPLACED WIITHIN SQUAD OPS PROJECT LIMITS IS 8"
UNREINFORCED CONCRETE
1. SEE SHEET C-002 FOR GENERAL NOTES.
2. EXISTING CONDITIONS PLAN HAS BEEN COMPILED FROM
MULTIPLE SOURCES INCLUDING DESIGN PLANS FOR THE
ADJACENT "REPAIR RAMP AREA IV" PROJECT (XDQU 072004)
PREPARED BY THOMAS & HUTTON, A TOPOGRAPHIC SURVEY
PREPARED BY KRI ENGINEERING, INC., AND G.I.S.
3. TOPOGRAPHIC SURVEY ENTITLED, "A TOPOGRAPHIC SURVEY
OF A PORTION OF THE GEORGIA AIR NATIONAL GUARD SITE
PREPARED FOR GEORGIA AIR NATIONAL GUARD" WAS
PREPARED BY KRI ENGINEERING, INC. WITH A FIELD DATE OF
10/6/12 AND A PLAT DATE OF 10/11/12.
4. THERE ARE NO KNOWN WETLAND AREAS FOUND WITHIN 200
FEET OF THE PROJECT AREA.
SHEET NOTES
CONTOUR LINE
x x x x x x x
CONTOUR LINE
UNDERGROUND CABLE
UNDERGROUND TELEPHONE
UNDERGROUND POWER
WATER LINE
CHAIN LINK FENCE
SANITARY SEWER
CENTER LINE OF DITCH
CENTER LINE OF ROAD
REINFORCED CONCRETE PIPE
UNDERGROUND GAS
WATER VALVE
TELEPHONE MANHOLE
ELECTRICAL JUNCTION BOX
WATER MANHOLE
FIRE HYDRANT
POLYVINYL CHLORIDE PIPE
WATER SHUTOFF
INVERT ELEVATION
TELEPHONE JUNCTION BOX
MONITORING WELL
BOLLARD
CLEANOUT
STORM DRAIN MANHOLE
POWER POLE
LIGHT POLE
SERVICE POLE
GAS METER
GRATE INLET
SANITARY SEWER MANHOLE
BOLLARD
BRADFORD PEAR TREE
CONCRETE PAVEMENT
CREPE MYRTLE
GUY WIRE
SPOT ELEVATION
1. THIS PROPERTY IS SUBJECT TO ANY AND ALL EASEMENTS,
COVENANTS, OR RESTRICTIONS EITHER RECORDED OR
UNRECORDED.
2. THE HORIZONTAL DATUM OF THIS SURVEY IS BASED ON GA
GRID ZONE EAST, NAD 83.
3. THE VERTICAL DATUM IS BASED ON NAVD 88.
4. THE UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED
FROM FIELD SURVEY INFORMATION, THE SURVEYOR MAKES
NO GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN
COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN
SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES
NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN
ARE IN THE EXACT LOCATION INDICATED, ALTHOUGH HE DOES
CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS
POSSIBLE FROM INFORMATION AVAILABLE.
5. NOT ALL STORM AND SANITARY SEWER FEATURES WERE
ACCESSIBLE TO OPEN.
TOPOGRAPHIC SURVEY NOTES
OVERHEAD POWER
PRESSURE TEST HYDRANT "G"
71 PSI STATIC
60 PSI RESIDUAL
@ 1130 GPM
PIN: 2-0984 -01-001
PARCEL AREA: 1,740.89 ACRES (PER TAX RECORD)
OWNER: SAVANNAH AIRPORT COMMISSION
ADDRESS: 400 AIRWAYS AVE
SAVANNAH, GA 31408-8000
PROPOSED LAND USE: FEDERAL GOV'T OFFICE
FLOOD ZONE: ZONE X - OTHER AREAS
FLOOD MAP NUMBER: 13051C0045F, EFFECTIVE 9/26/2008
TEST HYDRANT "F"
FLOW RATE = 1130 GPM
EXISTING REMEDIATION
WELL (TO BE PROTECTED
DURING CONSTRUCTION)
DO NOT DISTURB
EX. MONITORING
WELLS TO REMAIN
DO NOT DISTURB
EX. MONITORING
WELLS TO REMAIN
DO NOT DISTURB EX. MONITORING
WELLS TO REMAIN IN THIS AREA
M
O N
I T
O R
I N
G
W
E L L
C
L A
R I F
I C
A T
I O
N
File details come from the government source that posted it. Updated .