About this file

10 51 55

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UNCLASSIFIED/FOR OFFICIAL USE ONLY

Air National Guard NDDA Construct DGS RPA IS 60330398

SECTION 10 51 55

CELL PHONE LOCKERS

03/16

PART 1 GENERAL

1.1 SUMMARY

Section Includes:

1. Recessed cell phone lockers.

1.2 ACTION SUBMITTALS

A. Product Data: For each type of product.

1. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for cell phone lockers.

2. Where appropriate, in lieu of Product Data Action Submittal, submit Contractor's Certification Letter in accordance with Section 01 33 00

SUBMITTAL PROCEDURES.

B. Shop Drawings: For postal specialties.

1. Include plans, elevations, sections, and attachment details.

2. Include setting drawings, templates, and installation instructions for anchor bolts and other anchorages installed as part of the Work of other Sections.

C. Samples for Verification: For each type of exposed finish, prepared on 6-by-6-inch-square Samples.

1.3 INFORMATIONAL SUBMITTALS

Sample Warranty: For special warranty.

1.4 CLOSEOUT SUBMITTALS

Maintenance Data: For postal specialties and finishes to include in maintenance manuals.

1.5 DELIVERY, STOARGE, AND HANDLING

Furnish lock keys with units.

1.6 WARRANTY

A. Special Warranty: Manufacturer agrees to repair or replace components of cell phone lockers that fail in materials or workmanship within specified warranty period.

1. Failures include, but are not limited to, the following:

a. Structural failures.

SECTION 10 51 55 Page 1

Addendum 2

b. Faulty operation of hardware.

c. Deterioration of metals, metal finishes, and other materials beyond normal weathering.

2. Warranty Period: One year from date of Substantial Completion.

PART 2 PRODUCTS

2.1 CELL PHONE LOCKERS

Cell Phone Lockers: Consisting of fourty eight compartments with fixed, solid compartment backs, enclosed within recessed wall box. Access compartments from front of unit by unlocking lock and swinging side-hinged door.

1. Basis of Design: Model # 19038-06 by Salisbury Industries, Cell Phone Storage Locker, Recessed Mounted, with Master Keyed Locks

2. Compartments with Aluminum Doors: Manufacturer's standard compartments with extruded aluminum doors. Equip each with lock, identification, and concealed, full-length, flush hinge on one side.

a. Compartments: 6-1/2 by 5-1/4 by 8 inches.

3. Compartment-Door Locks: Spring-latch-type lock designed to accommodate keyed cylinders keyed to building keying system; with three keys for each compartment door and 50 key blanks .

4. Frames: Ganged and nested units.

5. Snap-on Trim: Fabricated from the same material and finish as compartment doors.

6. Concealed Components and Mounting Frames: Aluminum or steel sheet with manufacturer's standard finish.

7. Exposed Aluminum Finish: Finish surfaces exposed to view as follows:

a. Baked-Enamel or Powder-Coated Finish: Color as selected by Architect from manufacturer's full range.

8. Bid Item No. 0004 OPTION, Power Cell Phone Cubbies:

a. Provide flexible grommeted opening at back wall of each locker compartment for cell phone charging cables. Basis of Design Model #19960 by Salisbury Industries for use with compartment specified.

Charging cables: GFGI.

2.2 FABRICATION

A. Form units to required shapes and sizes, with true lines and angles, square, rigid, and without warp, and with metal faces flat and free of dents or distortion. Make exposed metal edges and corners free of sharp edges and burrs and safe to touch. Fabricate doors to preclude binding, warping, or misalignment.

B. Preassemble units in shop to greatest extent possible to minimize field assembly.

SECTION 10 51 55 Page 2

Amendment 2

C. Mill joints to a tight, hairline fit. Cope or miter corner joints.

D. Drill or punch holes required for fasteners and remove burrs. Use security fasteners where fasteners are exposed. If used, seal external rivets before finishing.

E. Weld in concealed locations to greatest extent possible without distorting or discoloring exposed surfaces. Remove weld spatter and welding oxides from exposed surfaces.

F. Fabricate tubular and channel frame assemblies with manufacturer's standard welded or mechanical joints. Provide subframes and reinforcement as required for a complete system to support loads.

2.3 FINISHES

A. Comply with NAAMM/NOMMA's "Metal Finishes Manual for Architectural and Metal Products (AMP 500-06)" for recommendations for applying and designating finishes.

B. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping.

C. Appearance of Finished Work: Noticeable variations in same piece are not acceptable. Variations in appearance of adjoining components are acceptable if they are within the range of approved Samples and are assembled or installed to minimize contrast.

PART 3 EXECUTION

3.1 EXAMINATION

A. Examine substrates, areas, and conditions for compliance with requirements for roughing-in openings, clearances, and other conditions affecting performance of the Work.

B. Examine walls and other adjacent construction for suitable conditions where units will be installed.

C. Prepare written report, endorsed by Installer, listing conditions detrimental to performance of the Work.

D. Proceed with installation only after unsatisfactory conditions have been corrected.

3.2 INSTALLATION

A. General: Install units level and plumb, according to manufacturer's written instructions and roughing-in drawings.

B. Install units at mounting height shown.

3.3 ADJUSTING, CLEANING, AND PROTECTION

A. Remove temporary protective coverings and strippable films, if any, as units are installed unless otherwise indicated in manufacturer's written installation instructions.

B. Adjust doors, hardware, and moving parts to function smoothly, and

SECTION 10 51 55 Page 3 lubricate as recommended by manufacturer. Verify that integral locking devices operate properly.

C. Touch up marred finishes or replace units that cannot be restored to factory-finished appearance. Use only materials and procedures recommended or furnished by manufacturer.

D. Replace units that have been damaged or have deteriorated beyond successful repair by finish touchup or similar minor repair procedures.

E. On completion of installation, clean interior and exterior surfaces as recommended by manufacturer.

-- End of Section --