W912HN-19-R-3004_AMD5_V1E.PDF
PDF 12 MB Posted
- Solicitation number
- W912HN19R3004
About this file
This document provides details for a forthcoming Request for Proposal for the construction of a Cyber Instructional Facility and Network Center at Fort Gordon, Georgia. Key information includes the project scope of constructing a Top Secret/Sensitive Compartmented Information level facility for training, research, and network operations. The contract will be firm-fixed-price with options. The period of performance is 780 calendar days. Evaluation will use the Lowest Price Technically Acceptable source selection process. The anticipated solicitation release date is March 19, 2019 with an approximate closing date of April 19, 2019. Offerors must register in the System for Award Management database. The point of contact is provided.
Drawings V1E
View the file
Other files
Show all 40
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
L V
LV3 LV3 LV3
LV3LV3
LV3
LV
L V
O S
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
DS
LV5 LV5 LV5 LV5
LV3
LV3
DS
LV3
L V
DS
LV3
LV3
OS
OS
OS
OS
LV3
OS
OS
OS OS
OS OS
OS OS
OS OS
OS OS
OS OS
OS OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OSOS
OSOS
OSOS
OSOS
DS
OS
LV3
OS
OS OS
LV3
LV
L V
L V
OS
5 6 7 8 9 10 11
C
K
F2 F2 F2
F2
F2 F2
F2F2F2
F2
F2
F2F2F2
B1
H2
H1
H1
B3 B3
B3
B3 B3
B3 B1
B1
X2
X1
N2
M A
T C
H
LIN
E
S E
E : E
L
1C
M A
T C
H
LI
N E
S
E E
E
L1
A
H1
H1
H2
N2N2N2N2
B1
N2N2N2 N2
B1
N2 N2
N2N2N2
H2 H2
F2
N2
Q QQ
Q
F
E
D
A
B
M
X1 X1
X1 X1
B3
W1
A1
EL401
A1
EL401
ELEV #1
111111
H2
H2
X1
G2
M MM
X1
G1
G1
X1
N2 N2 N2N2 N2 N2
CORRIDOR
129129
B3
B3
B3 B3 B3
B3
B3 B3 B3
B3
B3 B3 B3 B3
B3 B3 B3
B3 B3 B3
B3
B3
CORRIDOR
161161
CLASSROOM
164164
CLASSROOM
165165
CLASSROOM
162162
CLASSROOM
163163
CORRIDOR
110110
FEMALE TLT
112112
MALE TLT
113113
G6
131131
COMP MAINT
130130
G2
104104
TOILET
103103
BEF
127127
CORRIDOR
166166
BADGING/INTERVIEW
107107
G6
131131
B3 a Mb Mb c c c
M b Mb Ma c
M a M b Mb c c c b b a c
B3 B3 B3B3
G1
G1G1
SECURITY
102102
NON-SECURE
LOBBY
100100
SECURE LOBBY
101101
AUDITORIUM #1
105105
AUDITORIUM #2
106106
F3 F3 F3
F4 F4
M
F3 F3 F3
F4
N4
G2
G2 G2
G2
G2 G2
G2
CORRIDOR
132132
LPH1W1-1
LPH1W1-1
LPH1W1-1
LPH1W1-1
LPH1W1-1
LPH1W1-1
LPH1W1-1
LPH1W1-1
M
NPH1W1-7
NPH1M1-5
P
LPH1W1-5
LPH1W1-5
LPH1W1-5
LPH1W1-5
LPH1W1-5
LPH1W1-5
LPH1W1-5
LPH1W1-5
LPH1W1-5 LPH1W1-5
LPH1W1-5LPH1W1-5
NPH1M1-5
LPH1W1-5
LPH1M2-1
H2 H2
H1
H1
LPH1M2-1
NPH1M1-5
NPH1W1-5 NPH1W1-5
NPH1W1-5NPH1W1-5
NPH1M1-5
NPH1M1-5
NPH1M1-5
NPH1M1-5
LPH1M2-1
NPH1M1-5
NPH1M1-3
NPH1M1-3
NPH1M1-3
LPH1M2-1
NPH1M1-5
NPH1M1-5
NPH1M1-1
NPH1M1-1
NPH1W1-7NPH1W1-7
NPH1M1-1
LPH1W1-4
LPH1M2-5
LPH1W1-9
LPH1W1-9
N4
F2F2
F2F2 F2 F2
LPH1W1-5
D D
LPH1W1-5 LPH1W1-5
LPH1W1-1 LPH1W1-1
LPH1W1-1 LPH1W1-1
JC
114114
NPH1M1-5
CORRIDOR
110110
LPH1M2-1
LPH1M2-1
F2F2
LPH1W1-5
LPH1W1-3NPH1W1-3
NPH1W1-3 LPH1W1-3
NPH1M1-3
NPH1M1-3
NPH1M1-3
NPH1M1-3
X1
LPH1W1-7
N2
LPH1W1-5
N2 N2
NPH1M1-5
NPH1M1-5 NPH1M1-5
F1 F1
Q
H1 H1
LPH1W1-5
NPH1M1-5
H2
F2F2
NPH1M1-5 LPH1W1-5
LPH1W1-5 LPH1W1-5
LPH1W1-5
LPH1W1-5
LPH1W1-5
LPH1W1-5LPH1W1-5LPH1W1-5
Q
LPH1W1-5
B3
NPH1M1-1
CORRIDOR
161161
NPH1M1-3 NPH1M1-3
NPH1M1-3NPH1M1-3
NPH1M1-3
NPH1M1-3
NPH1M1-3
NPH1M1-5 NPH1M1-5
NPH1M1-5NPH1M1-5
NPH1M1-5
NPH1M1-5 NPH1M1-5
NPH1M1-5
NPH1M1-5
NPH1M1-5
NPH1M1-5
X1X1
N2
N2
N2
N2
N2
N2
P
N2
N2
N2
N2
N2
N2
N2
SPPN
128128
N4 N4
Q
LPH1M2-10
W2
LPH1M2-10
W2
LPH1M2-10
W2
LPH1M2-10
W2
W2
LPH1M2-10
LPH1W1-5
Q
X1
NPH1M1-5
G1
F4
LPH1W1-5
F4
F4
F4
F4
F4
F4
F4
F4
X1
X1
LPH1W1-5 LPH1W1-5 LPH1W1-5
LPH1W1-3
LPH1W1-3
LPH1W1-5 LPH1W1-5LPH1W1-5LPH1W1-5
Z
Z
Z
Z
Z
Z
NPH1W1-7 NPH1W1-7
LPH1W1-3
LPH1W1-3
Q
16 1
(TYP)
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
C:\_Revit_Local_Models\2018\10053876-E-MCA1-Central_CH_diane.riosEZM7N.rvt
6/25/2019 12:22:53 PM
EL101B
MCA1
E L E
C T
R
IC
A L
L
IG
H T
IN
G
P L A
N
L E
V E
L
A
R E
A B
F O
R T
G O
R D
O N
G
A
W
E S
T O
G L E
T H
O R
P E
A V
E N
U E
D A
V A
N N
A H
D
IS
T R
IC
T
S A
V A
N N
A H
G
A
H D
R A
R L
IN
G T
O N
V
IR
G
IN
A
L G
L A
S E
R
D R
IO
S
J A
M U
R R
A Y
T L Y
M A
N
F E
B R
U A
R Y
W H
N -1
-R
-3
-3
-0
C
A T
E G
O R
Y C
O D
E
ISSUED FOR CONSTRUCTION
S C
I T
R A
IN
IN
G R
E S
E A
R C
H
N E
T W
O R
K C
E N
T E
R
F Y
I, P
N
1/8" = 1'-0" A1
LIGHTING PLAN - LEVEL 1, AREA B
KEYED NOTES
1. PROVIDE 3 LOW VOLTAGE 3 BUTTON LIGHT
SWITCHES WITH RAISE/LOWER FEATURES IN THE
ROOM. CONTROLS SHALL a, b, c AND CONTROL
ASSOCIATED LIGHTS WITHIN THAT SPACE.
2. LIGHTS IN SPACE CONTROLLED BY FIXTURE
MOUNTED OCCUPANCY SENSOR.
3. LIGHT FIXTURE "Q" SHALL RUN ON THE TOP AND
SIDES OF THE MIRROR. COORDINATE LOCATION
WITH ARCHITECTURE.
4. LIGHT FIXTURE TO BE RECESSED IN THE STAIR
ABOVE.
5. PROVIDE AV CONTROL INTERFACE TO INTEGRATE
LIGHTS WITH AV EQUIPMENT IN THE SPACE.
6. FIXTURE SHALL BE WALL MOUNTED 3' ABOVE PIT
FLOOR.
7. PROVIDE PARTITION CONTACT CLOSURE TO
INTEGRATE WALL DIVIDER WITH LIGHTING
CONTROLS IN THE ROOM.
8. UNLESS OTHERWISE NOTED, CIRCUIT ALL LIGHTS
IN THIS SPACE TO THE CIRCUIT LISTED ADJACENT
TO THIS KEY NOTE.
9. ALL OCCUPANCY SENSORS IN THIS SPACE SHALL
HAVE A BLACK FINISH.
10. LIGHT FIXTURE WILL RUN VERTICAL ALONG FULL
LENGTH OF WALL.
11. LIGHT FIXTURE "Q" RUNS IN TOE KICK OF DESK.
REFER TO ARCHITECTURAL PLANS FOR DETAILS.
12. FIXTURES IN THIS AREA SHALL BE MOUNTED AT
9' - 6" AFF.
13. INSTALL "W2" IN THE BAGUETTES LOCATED ABOVE
THE ENTRY DOORS. REFER TO ARCHITECTURAL
PLANS FOR DETAILS.
14. ALL LIGHTS IN SPACE SHALL BE CAPABLE OF
DIMMING TO 0.1%.
15. HANDRAIL LIGHT, CIRCUIT AS INDICATED, REFER
TO ARCHITECTURAL SPECIFICATIONS FOR
DETAILS.
16. ALL OCCUPANCY SENSORS AND LIGHT SWITCHES
IN THIS SPACE SHALL HAVE A BLACK FINISH.
17. PROVIDE FIXTURE WITH BLACK FLANGE TO MATCH
SPACE.
GENERAL NOTES
NORTH
B C
KEY PLAN
A
1 1
1 1 1
3 3
1. REFER TO SHEET E-001 AND E-002 FOR SYMBOLS,
LEGEND AND GENERAL NOTES.
2. REFER TO SHEET EL-501 & EL-502 FOR LIGHTING
FIXTURE DETAILS.
3. REFER TO SHEET EL-620 FOR LIGHTING CONTROL
MATRIX.
4. UNLESS OTHERWISE NOTED, REFER TO LIGHTING
FIXTURE SCHEDULE ON EL-630 FOR MOUNTING
HEIGHT OF ALL PENDANT AND WALL MOUNTED
FIXTURES.
5. WHEN EMERGENCY FIXTURE IS NOTED ON A
LINEAR PRODUCT. MINIMUM 4' OF PRODUCT MUST
BE CONNECTED TO INVERTER CIRCUIT THE REST
WILL BE ON NORMAL POWER.
6. ALL EXIT SIGNS ARE CIRCUITED TO LPH1W1-6.
7 7
5 5
8 8
8 8
6 6
7 7
3 3
10 10
8'4' 16'0
SCALE: 1/8"=1'-0"
8'4' 16'0
SCALE: 1/8"=1'-0"
10 8
14 14
15 15
R
E V
IS
IO
N
/2
/1
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/2
/1
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/2
/1
DSDS
LV3 LV3
LV
L V
LV3
O S
OS
OS OS
OS OS
OS OS
OSOS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS OS
OS
OS
OS
OS
OS
OS
OS
OSOS
OS
OS
OS
OS
OS
OS
OS
OS
OSOS
OS OS
OS OS
OS
OS
OS
OS
L V
LV3 LV3 LV3 LV3 LV3 LV3 LV3 LV3
LV3LV3
DS
LV3 LV3 LV3
5 6 7 8 9 10 11
C
CLASSROOM
234234
CLASSROOM
235235
CLASSROOM
236236
CLASSROOM
262262
CLASSROOM
263263
CLASSROOM
264264
CLASSROOM
265265
CORRIDOR
222222
ELEV #1
211211
CORRIDOR
261261
MALE TLT
213213
JC
214214
CORRIDOR
210210
X1
X1
B1
G1
FEMALE TLT
212212
F2
F2
F2
F2 F2 F2
F2F2F2
G1
CLASSROOM
233233
G2
G2
N2 N2N2 N2 N2N2 N2 N2 N2N2 N2N2 N2 N2N2 N2
N2N2N2 N2N2N2 N2N2N2N2N2 N2N2 N2 N2N2
F2
M A
T C
H L
IN
E
S
E E
E
L
A
M A
T C
H L
IN
E
S
E E
: E L
C
Q QQ
Q
F
E
D
B
M M M
M M M
M M M
M M M
M M M
M M M
M M M
M M M
X1 X1
X1
X1
X1 X1
A1
EL401
A1
EL401
G2 G2 G2
F2
F2
F2
F2
F2
F2
F2 a b b c c c b b a c a b b c c c b b a c a b b a b b b b a b b a c c c c c c c c
X1
F2F2
F2F2
G2
G2G2
G2 G2
G2
G2 G2
G2
G2G2
LPH1W1-8 NPH1W1-6
LPH1W1-8 LPH1W1-8
LPH1W1-8 NPH1W1-6
NPH1W1-6
NPH1W1-6 LPH1W1-8
LPH1W1-8
LPH1W1-8
LPH1W1-8
NPH1W1-4 LPH1W1-6
NPH1M1-8
NPH1M1-8
LPH1M2-8
LPH1M2-8
LPH1M2-8
LPH1M2-8
NPH1M1-8
NPH1M1-8
NPH1M1-6
NPH1M1-8
LPH1M2-8
LPH1M2-8 NPH1M1-2
LPH1M2-8
LPH1M2-8 NPH1M1-2
LPH1M2-8
LPH1M2-8NPH1M1-8NPH1M1-8 LPH1M2-8
LPH1M2-8
NPH1M1-8
LPH1M2-8
NPH1M1-6 CORRIDOR
229229
CORRIDOR
210210
LPH1M2-8CORRIDOR
266266
G2
NPH1M1-8
CORRIDOR
210210
QQ Q
X1
LPH1W1-6
LPH1W1-8 LPH1W1-8
LPH1W1-8
LPH1W1-8
LPH1M2-8 LPH1M2-8
LPH1M2-8LPH1M2-8
LPH1M2-8
LPH1M2-8
F2
X1 X1NPH1M1-6 NPH1M1-6
F1 F1
N4
LPH1W1-9
N4
LPH1W1-9
LPH1M2-6
X1
LPH1M2-8
X1 X1
X1
LPH1W1-6 LPH1W1-6 LPH1M2-8 LPH1M2-8 LPH1M2-8
LPH1M2-8LPH1M2-8LPH1W1-6LPH1W1-6
NPH1W1-4
1 1
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
C:\_Revit_Local_Models\2018\10053876-E-MCA1-Central_CH_diane.riosEZM7N.rvt
6/25/2019 12:23:03 PM
EL102B
MCA1
E L E
C T
R
IC
A L
L
IG
H T
IN
G
P L A
N
L E
V E
L
A
R E
A B
F O
R T
G O
R D
O N
G
A
W
E S
T O
G L E
T H
O R
P E
A V
E N
U E
D A
V A
N N
A H
D
IS
T R
IC
T
S A
V A
N N
A H
G
A
H D
R A
R L
IN
G T
O N
V
IR
G
IN
A
L G
L A
S E
R
D R
IO
S
J A
M U
R R
A Y
T L Y
M A
N
F E
B R
U A
R Y
W H
N -1
-R
-3
-3
-0
C
A T
E G
O R
Y C
O D
E
ISSUED FOR CONSTRUCTION
S C
I T
R A
IN
IN
G R
E S
E A
R C
H
N E
T W
O R
K C
E N
T E
R
F Y
I, P
N
1/8" = 1'-0" A1
LIGHTING PLAN - LEVEL 2, AREA B
KEYED NOTES
1. PROVIDE 3 LOW VOLTAGE 3 BUTTON LIGHT
SWITCHES WITH RAISE/LOWER FEATURES IN THE
ROOM. CONTROLS SHALL a, b, c AND CONTROL
ASSOCIATED LIGHTS WITHIN THAT SPACE.
2. LIGHT FIXTURE "Q" SHALL RUN ON THE TOP AND
SIDES OF THE MIRROR. COORDINATE LOCATION
WITH ARCHITECTURE.
3. LIGHT FIXTURE TO BE RECESSED IN THE STAIR
ABOVE.
4. ALL OCCUPANCY SENSORS IN THIS SPACE SHALL
HAVE A BLACK FINISH.
5. PROVIDE PARTITION CONTACT CLOSURE TO
INTEGRATE WALL DIVIDER WITH LIGHTING
CONTROLS IN THE ROOM.
6. PROVIDE AV CONTROL INTERFACE TO INTEGRATE
LIGHTS WITH AV EQUIPMENT IN THE SPACE.
7. UNLESS OTHERWISE NOTED, CIRCUIT ALL LIGHTS
IN THIS SPACE TO THE CIRCUIT LISTED ADJACENT
TO THIS KEY NOTE.
8. ALL OCCUPANCY SENSORS AND LIGHT SWITCHES
IN THIS SPACE SHALL HAVE A BLACK FINISH.
9. PROVIDE FIXTURE WITH BLACK FLANGE TO MATCH
SPACE.
1 1
GENERAL NOTES
NORTH
B C
KEY PLAN
A
1. REFER TO SHEET E-001 AND E-002 FOR SYMBOLS,
LEGEND AND GENERAL NOTES.
2. REFER TO SHEET EL-501 & EL-502 FOR LIGHTING
FIXTURE DETAILS.
3. REFER TO SHEET EL-620 FOR LIGHTING CONTROL
MATRIX.
4. UNLESS OTHERWISE NOTED, REFER TO LIGHTING
FIXTURE SCHEDULE ON EL-630 FOR MOUNTING
HEIGHT OF ALL PENDANT AND WALL MOUNTED
FIXTURES.
5. WHEN EMERGENCY FIXTURE IS NOTED ON A
LINEAR PRODUCT. MINIMUM 4' OF PRODUCT MUST
BE CONNECTED TO INVERTER CIRCUIT THE REST
WILL BE ON NORMAL POWER.
6. ALL EXIT SIGNS CIRCUITED TO LPH1W1-10.
7. ALL LIGHTING ON THIS FLOOR SHALL BE
CIRCUITED TO PANELBOARDS ON FIRST FLOOR IN
ROOMS 171, 144, AND 141.
1 1 1 1
5 5
6 6
7 7
7 7
2 2
6 6
8'4' 16'0
SCALE: 1/8"=1'-0"
R
E V
IS
IO
N
/2
/1
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/2
/1
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/2
DS
LV3
L V
LV
L V
LV3LV3LV3LV3
OS
OS
OS OS
OS OS
OS OS
OS OS
OS OS
OS OS
OS OS
OS OS
OS OS
OS OS
OS
OS
OS
OS
OS
OS
OS
OS OS
OS
OSOS
OS OS
OS OS
OS OS
OS OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
LV3LV3LV3
DS
OS
5 6 7 8 9 10 11
C
CLASSROOM
334334
CLASSROOM
335335
CLASSROOM
336336
CLASSROOM
362362
CLASSROOM
363363
CLASSROOM
364364
CLASSROOM
365365 CLASSROOM
333333
FEMALE TLT
312312
CORRIDOR
310310
MALE TLT
313313
JC
314314
CORRIDOR
366366
X1
X1
M M MM M MM M MM M M
F2
B1
G2
M M M
G2
M M M
G2
M M M
N2N2N2N2N2N2N2N2N2
N2N2N2N2N2N2N2N2N2
N2N2N2N2N2N2N2
N2 N2N2N2N2N2N2
M A
T C
H L
IN
E
S
E E
E
L
A
M A
T C
H L
IN
E
S
E E
: E L
C
Q
Q Q Q
F
E
D
B
F2
F2 F2
F2
F2 F2 F2
F2F2F2
Q Q
X1
F2
F2
F2
F2
F2
F2
F2 a b b c c c b b a c a b b c c c b b a c a b b a b b b b a b b a c c c c c c c c
G2
M M M
X1
G2 G2
G2 G2 G2 G2
G2 G2
G2 G2 G2G2
F2F2
F2F2
G1
LPH3W1-1
LPH3W1-1
LPH3W1-1
LPH3W1-1
LPH3W1-1 NPH3W1-3
LPH3W1-1
LPH3W1-1 NPH3W1-3
LPH3E1-3NPH3E1-5
LPH3E1-3
LPH3E1-3
NPH3E1-5
LPH3E1-3
LPH3E1-3 NPH3E1-3
LPH3E1-3
LPH3E1-3
NPH3E1-3
LPH3E1-3
LPH3E1-3 NPH3E1-5
NPH3E1-5
NPH3E1-5
LPH3E1-3LPH3W1-1CORRIDOR
361361
NPH3W1-3
LPH3W1-1 NPH3W1-3
LPH3W1-1
NPH3W1-3 LPH3W1-1 CORRIDOR
366366
LPH3E1-3
LPH3E1-3
CORRIDOR
310310
LPH3E1-3
NPH3E1-5 CORRIDOR
322322
ELEV #1
311311
CORRIDOR
322322
G2
NPH3E1-3
NPH3E1-5
LPH3E1-3
NPH3E1-5
G2 c
G2 c
G2c
G2c
G2c
G2c
G2c
G2c
LPH3E1-3 LPH3E1-3
LPH3E1-3 LPH3E1-3LPH3W1-1 LPH3W1-1
LPH3W1-1NPH3W1-3 LPH3W1-1
LPH3W1-1
NPH3E1-5
F1
NPH3E1-5
F1
LPH3E1-3
H1
X1
X1 X1
X1
G1
NPH3E1-5
Q
LPH3W1-1 LPH3W1-1 LPH3E1-3 LPH3E1-3
LPH3E1-3LPH3E1-3LPH3E1-3
LPH3W1-1
LPH3E1-3
LPH3E1-3
F2
F2
F2
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
C:\_Revit_Local_Models\2018\10053876-E-MCA1-Central_CH_diane.riosEZM7N.rvt
6/25/2019 12:23:12 PM
EL103B
MCA1
E L E
C T
R
IC
A L
L
IG
H T
IN
G
P L A
N
L E
V E
L
A
R E
A B
F O
R T
G O
R D
O N
G
A
W
E S
T O
G L E
T H
O R
P E
A V
E N
U E
D A
V A
N N
A H
D
IS
T R
IC
T
S A
V A
N N
A H
G
A
H D
R A
R L
IN
G T
O N
V
IR
G
IN
A
L G
L A
S E
R
D R
IO
S
J A
M U
R R
A Y
T L Y
M A
N
F E
B R
U A
R Y
W H
N -1
-R
-3
-3
-0
C
A T
E G
O R
Y C
O D
E
ISSUED FOR CONSTRUCTION
S C
I T
R A
IN
IN
G R
E S
E A
R C
H
N E
T W
O R
K C
E N
T E
R
F Y
I, P
N
NORTH
B C
KEY PLAN
A
1/8" = 1'-0" A1
LIGHTING PLAN - LEVEL 3, AREA B
GENERAL NOTES
KEYED NOTES
1. PROVIDE 3 LOW VOLTAGE 3 BUTTON LIGHT
SWITCHES WITH RAISE/LOWER FEATURES IN THE
ROOM. CONTROLS SHALL a, b, c AND CONTROL
ASSOCIATED LIGHTS WITHIN THAT SPACE.
2. LIGHT FIXTURE "Q" SHALL RUN ON THE TOP AND
SIDES OF THE MIRROR. COORDINATE LOCATION
WITH ARCHITECTURE.
3. ALL OCCUPANCY SENSORS IN THIS SPACE SHALL
HAVE A BLACK FINISH.
4. PROVIDE AV CONTROL INTERFACE TO INTEGRATE
LIGHTS WITH AV EQUIPMENT IN THE SPACE.
5. UNLESS OTHERWISE NOTED, CIRCUIT ALL LIGHTS
IN THIS SPACE TO THE CIRCUIT LISTED ADJACENT
TO THIS KEY NOTE.
6. ALL OCCUPANCY SENSORS AND LIGHT SWITCHES
IN THIS SPACE SHALL HAVE A BLACK FINISH.
7. PROVIDE FIXTURE WITH BLACK FLANGE TO MATCH
SPACE.
1 1 1 1
2 2
1. REFER TO SHEET E-001 AND E-002 FOR SYMBOLS,
LEGEND AND GENERAL NOTES.
2. REFER TO SHEET EL-501 & EL-502 FOR LIGHTING
FIXTURE DETAILS.
3. REFER TO SHEET EL-620 FOR LIGHTING CONTROL
MATRIX.
4. UNLESS OTHERWISE NOTED, REFER TO LIGHTING
FIXTURE SCHEDULE ON EL-630 FOR MOUNTING
HEIGHT OF ALL PENDANT AND WALL MOUNTED
FIXTURES.
5. WHEN EMERGENCY FIXTURE IS NOTED ON A
LINEAR PRODUCT. MINIMUM 4' OF PRODUCT MUST
BE CONNECTED TO INVERTER CIRCUIT THE REST
WILL BE ON NORMAL POWER.
6. ALL EXIT SIGNS ARE CIRCUITED TO LPH3W1-2.
2 2
4 4
4 4
5 5
5 5
4 4
8'4' 16'0
SCALE: 1/8"=1'-0"
R
E V
IS
IO
N
/2
/1
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/2
/1
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/2
UP
T ectonic Cop yright 2007
UP
J
J
J
J
J
VFD
M A
T C
H
LI
N E
S
E : A
1/ E
P
1B
SPPN
STAIR #2
ELEV #2
TEL
MECH
CORRIDOR
CORRIDOR
ELEC
STAIR #3
11 12 13 14 15 16
F
E
D
C
B
WP
GFI
GFI
WP
GFI
GFI GFI
EW
EW
E-401
A4 E-403
A1
E-402
A1
ELEC
INVERTER
FIRE
PUMP
LOADING
BATTERY
E-404
A1
IRC-30
IRC-29
IRC-28
IRC-27
IRC-31
IRC-32
IRC-33
IRC-34
IRC-38
IRC-37
IRC-36
IRC-35
IRC-39
IRC-40
IRC-41
IRC-42
IRC-43
IRC-44
IRC-50
IRC-49
IRC-48
IRC-47
IRC-46
IRC-45
IRC-51
IRC-52
IRC-58
IRC-57
IRC-56
IRC-55
IRC-54
IRC-53
IRC-59
IRC-60
IRC-61
IRC-62
IRC-66
IRC-65
IRC-64
IRC-63
IRC-67
IRC-68
IRC-69
IRC-70
IRC-71
IRC-72
IRC-78
IRC-77
IRC-76
IRC-75
IRC-74
FCU-22
CRAH-1 CRAH-2
M
GFI
GFI
WP
WP
GFI
WP
GFI
M SP-2
UH-1
B A
T T
A
B A
T T
A
B A
T T
A
B A
T T
B
B A
T T
A
B A
T T
A
B A
T T
B
B A
T T
B
B A
T T
B
U U
P S
1M -1
U D
H 1M
UUPS1M-2
B A
T T
B
DISC A
DISC B
LVR1M1 BATT CAB
BATT CABBATT CAB
GFI
GFIGFI
N S
G 1M
WP
GFI
WP
GFI
QPH1M1
QDH1M1
UQDH1M1
QTR1M1
QPL1M1
NPL1M1
NPL1M2
NDH1M1
T
UTR1M21
LPH1M2
NPL1ET1
M
T
CRAH-7
CRAH-3
CRAH-6
QPL1M1-25
QPH1M1-7,9,11
QPH1M1-8,10,12
NPL1M2-9
EF-4
QPL1M1-27
CRAH-4
QPL1M1-29
NPL1M2-2
NPL1M2-4,<unnamed>
CRAH-5
ATS
LPH1M1
NDL1M1
NPH1M1
QDL1M1
T
UTR1M19
UTR1M20
UTR1M18UTR1M17UTR1M16UTR1M15UTR1M14UTR1M13UTR1M12UTR1M11UTR1M10UTR1M9UTR1M8UTR1M7UTR1M6UTR1M5UTR1M4
UDL1M1
UDL1M2
UDL1M3
UDL1M4
UDL1M5
UDL1M6
UDL1M7
UDL1M8
UDL1M9
UDL1M10 UDL1M12 UDL1M14
UDL1M15
UDL1M16
UDL1M17
UDL1M18
UDL1M19
UDL1M11
UA1M3 UA1M5
ATS
NPL1M2-11
NPL1M2-11
UDL1M20UDL1M13
QPL1M1-26
NPL1M2-15,6
CV8-144.1
CV4-126.1
CVR8-145.1
CV7-128.1
NTR1M1
NPL1M2-10
QPL1M1-31
CRAH-8
QDH1M1-13 QDH1M1-15
LPL1M1
LTR1M1
EDL1M1
EF-1
EF-2
T T
EDL1M2
WP
WP
WP NPL1M1-11
NPL1M1-13
WP
GFI
NPL1M1-15
A. REFER TO SHEET E-001 AND E-002 FOR SYMBOLS,
ABBREVIATIONS AND ADDITIONAL INSTALLATION
REQUIREMENTS.
B. REFER TO SHEET E-600 SERIES FOR ELECTRICAL ONE LINE
DIAGRAMS.
C. SEE E-701 FOR FEEDER AND TRANSFORMER SCHEDULE.
D. ALL ELECTRICAL EQUIPMENT IS NEW UNLESS NOTED
OTHERWISE.
E. CONDUIT AND WIRE IS SHOWN DIAGRAMMATICALLY. ACTUAL
ROUTING AND REQUIRED NUMBER OF SUPPORTS SHALL BE
DETERMINED BY THE CONTRACTOR.
F. UNLESS CONDUIT ROUTING CLEARLY INDICATES AS SUCH, DO
NOT ROUTE CONDUIT ON OR ABOVE ROOFTOPS WITHOUT
CONSULTING ENGINEER TO DETERMINE ANY POTENTIAL
IMPACT TO RACEWAY OR CONDUCTOR SIZE DUE TO
ADDITIONAL AMBIENT DERATING FOR ROOFTOP INSTALLATION.
G. CONCEAL CONDUITS IN ALL FINISHED AREAS INCLUDING
CONCEALMENT WITHIN MASONRY WALLS WHEN PRESENT.
(EXCEPTION: ELECTRICAL, MECHANICAL, AND JANITOR ROOMS).
H. FLOOR AND FIRE WALL PENETRATIONS MUST BE SEALED WITH
AN APPROVED DESIGN TESTED FIRE STOPPING SYSTEM
APPROPRIATE TO THE PENETRATED WALL TYPE INSTALLED IN
ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS. REFER
TO E-500 SERIES DRAWINGS FOR FIRE PENETRATION DETAIL.
I. WHEN OVERHEAD ELECTRICAL WORK IS EXPOSED: MOUNTING
OF ALL ELECTRICAL WORK/CONDUIT SHALL RUN IN DECK
FLUTES AND/OR TIGHT WITH DECK. CONTRACTOR MAY RUN
CONDUIT UNDER FLOOR AS NECESSARY TO FACILITATE
CONCEALMENT OF CONDUITS.
J. PRIOR TO ROUGH-IN AND FINAL CONNECTION, VERIFY
ELECTRICAL CHARACTERISTICS AND EXACT LOCATION OF THE
EQUIPMENT.
K. INSTALL ALL CONDUITS PARALLEL PERPENDICULAR AND
UNIFORM TO BUILDING ELEMENTS
L. NO MORE THAN 180 DEGREE OF CONDUIT BENDS ARE ALLOWED
IN ANY INTERIOR CONDUIT RUNS.
M. IDENTIFY ALL CONDUIT RUNS WITH MARKER TAPE.
N. WHEN MORE THAN 3 CURRENT CARRYING CONDUCTORS ARE
INSTALLED WITHIN A SINGLE CONDUIT DERATE CONDUCTOR
AMPACITY PER NEC 310.15(B)(3)(a). CONTRACTOR SHALL UPSIZE
CONDUCTORS AS REQUIRED.
O. THE BUSWAY SHALL BE PROVIDED WITH BRACING PER UFC
4-010-01 ATFP REQUIREMENT.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
C:\rvt\2018\10053876-M-MCA1-Central_TSCHNEPF.rvt
6/25/2019 8:44 AM
EP101C
MCA1
E L E
C T
R
IC
A L
P O
W E
R P
L A
N
L E
V E
L
A
R E
A C
F O
R T
G O
R D
O N
G
A
W
E S
T O
G L E
T H
O R
P E
A V
E N
U E
S A
V A
N N
A H
D
IS
T R
IC
T
S A
V A
N N
A H
G
A
H D
R A
R L
IN
G T
O N
V
IR
G
IN
IA
D A
D A
M
J E
S T
R A
D A
J A
M
U R
R A
Y
L B
A Y
L O
N
F E
B R
U A
R Y
W H
N -1
-R
-3
-3
-0
C
A T
E G
O R
Y C
O D
E
ISSUE FOR CONSTRUCTION
S C
I T
R A
IN
IN
G R
E S
E A
R C
H
N E
T W
O R
K C
E N
T E
R
F Y
P
N
8'4' 16'0
SCALE: 1/8"=1'-0"
1/8" = 1'-0" A1
ELECTRICAL - POWER PLAN - LEVEL 1 - AREA C
NORTH
B C
KEY PLAN
A
GENERAL NOTES
KEYNOTES
1. POWER CONNECTION FOR MECHANICAL EQUIPMENT.
2. POWER FOR CONNECTION FOR OVERHEAD DOOR.
3. PRIMARY SWITCH AND TRANSFORMER PROVIDED AND
INSTALLED BY GEORGIA POWER.
4. POWER CONNECTION FOR FIRE PUMP/CONTROLLER.
5. UNDERGROUND CONCRETE ENCASED DUCTBANK FOR CAM
LOCK AND PORTABLE LOAD BANK. SEE SHEET ES-101 FOR
CONTINUATION.
6. UNISTRUT SUPPORT FOR VERTICAL RISERS AS REQUIRED.
7. UNDERGROUND CONCRETE ENCASED DUCTBANK FOR UTILITY
YARD TRANSFORMERS.
8. DASHED LINE INDICATES SECURE AREA BOUNDARY.
9. POWER CONNECTION FOR SECURITY CAMERA. COORDINATE
LOCATION AND ELEVATION WITH SECURITY CONTRACTOR.
10. SPARE 2" CONDUIT FROM UTILITY TRANSFORMER TO
MECHANICAL ROOM. STUB UP IN CORNER OF MECHANICAL
ROOM. FOR TRANSFORMER METERING.
(TYP.)
R
E V
IS
IO
N
/2
/1
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/2
/1
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/2
UPDN
UP DN
J J
J
J J J
J J
J
J J
J
E-401
C1
M A
T C
H
LI
E : A
1/ E
P
2B
STAIR #4
STUDENT
BREAK
CONF 5-7
P
CORRIDOR
CLASSROOM
CORRIDOR
ELEC
TEL
MECH
SHAFT
STUDENT
RECORDS
STAIR #5
CAVE
CORRIDOR
NPL2W1
NPL2W3
NTR2W1
1 2 4 5
F
E
D
C
B
GFI
+48"
CLASSROOM
UPFOLDING PANEL PARTITION
INSTRUCTOR
M M
M
M
M
PDM
PDM
PDM
PDM
PDM
PDM
M
M
CLASSROOM
CLASSROOM
+60"
+48" +48"
+48"
+90"
NPL2W4
PDM
NPL2WT1
NPL2W2
3 5
2 4
PDM
PDM
16 18
17 19
NPL2W1-1,3,5,7,9,11
NPL2W1-2,4,6,8,10,12,14
NPL2W1-17,19,21,23,25,27
NPL2W2-1,3,5,7,9,11
NPL2W2-2,4,6,8,10,12
NPL2W2-15,17,19,21,23,25
NPL2W2-16,18,20,22,24,26
NPL2W3-31,33,35
NDL2W1
+48"
NPL2W5-2
NPL2W1-31
NPL2W5-4
NPL2W3-32,34
+48"
+24"
T
M
11 25
PDM
NPL2W1-32
NPL2W1-16,18,20,22,24,26,28
M
M
DNTR2W1
QPL2W1
QPL2W1-1
QPL2W1-3
QPL2W1-7
M
QPL2W1-11,13,15
M
16 18 20
19 21
33 35
+24"
NPL2W5-1
NPL2W5-7
NPL2W5-5
NPL2W5-3
NPL2W5
NPL2W1-15
NPL2W1-29
22 24 26
NPL2W2-28
NPL2W2-27
NPL2W3-37
NPL2W3-30
NPL2W3-28
NPL2W3-11
LPL1M1-10
+48"
+48"
NPL2W2-14
QPL2W1-9
+48"
NPL2W1-30
+48"
+48"
NPL2W4-14
NPL2W1-13 +48"
+48"
+48" +48"
+48"
+48"
+48"
+48"
+48" +48"
+60"
NPL2W5-6
A. REFER TO SHEET E-001 AND E-002 FOR SYMBOLS,
ABBREVIATIONS AND ADDITIONAL INSTALLATION
REQUIREMENTS.
B. REFER TO SHEET E-600 SERIES FOR ELECTRICAL ONE LINE
DIAGRAMS.
C. SEE E-701 FOR FEEDER AND TRANSFORMER SCHEDULE.
D. ALL ELECTRICAL EQUIPMENT IS NEW UNLESS NOTED
OTHERWISE.
E. CONDUIT AND WIRE IS SHOWN DIAGRAMMATICALLY. ACTUAL
ROUTING AND REQUIRED NUMBER OF SUPPORTS SHALL BE
DETERMINED BY THE CONTRACTOR.
F. UNLESS CONDUIT ROUTING CLEARLY INDICATES AS SUCH, DO
NOT ROUTE CONDUIT ON OR ABOVE ROOFTOPS WITHOUT
CONSULTING ENGINEER TO DETERMINE ANY POTENTIAL
IMPACT TO RACEWAY OR CONDUCTOR SIZE DUE TO
ADDITIONAL AMBIENT DERATING FOR ROOFTOP INSTALLATION.
G. CONCEAL CONDUITS IN ALL FINISHED AREAS INCLUDING
CONCEALMENT WITHIN MASONRY WALLS WHEN PRESENT.
(EXCEPTION: ELECTRICAL, MECHANICAL, AND JANITOR ROOMS).
H. FLOOR AND FIRE WALL PENETRATIONS MUST BE SEALED WITH
AN APPROVED DESIGN TESTED FIRE STOPPING SYSTEM
APPROPRIATE TO THE PENETRATED WALL TYPE INSTALLED IN
ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS. REFER
TO E-500 SERIES DRAWINGS FOR FIRE PENETRATION DETAIL.
I. WHEN OVERHEAD ELECTRICAL WORK IS EXPOSED: MOUNTING
OF ALL ELECTRICAL WORK/CONDUIT SHALL RUN IN DECK
FLUTES AND/OR TIGHT WITH DECK. CONTRACTOR MAY RUN
CONDUIT UNDER FLOOR AS NECESSARY TO FACILITATE
CONCEALMENT OF CONDUITS.
J. PRIOR TO ROUGH-IN AND FINAL CONNECTION, VERIFY
ELECTRICAL CHARACTERISTICS AND EXACT LOCATION OF THE
EQUIPMENT.
K. INSTALL ALL CONDUITS PARALLEL PERPENDICULAR AND
UNIFORM TO BUILDING ELEMENTS
L. NO MORE THAN 180 DEGREE OF CONDUIT BENDS ARE ALLOWED
IN ANY INTERIOR CONDUIT RUNS.
M. IDENTIFY ALL CONDUIT RUNS WITH MARKER TAPE.
N. WHEN MORE THAN 3 CURRENT CARRYING CONDUCTORS ARE
INSTALLED WITHIN A SINGLE CONDUIT DERATE CONDUCTOR
AMPACITY PER NEC 310.15(B)(3)(a). CONTRACTOR SHALL UPSIZE
CONDUCTORS AS REQUIRED.
O. THE BUSWAY SHALL BE PROVIDED WITH BRACING PER UFC
4-010-01 ATFP REQUIREMENT.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
C:\rvt\2018\10053876-M-MCA1-Central_TSCHNEPF.rvt
6/25/2019 8:44 AM
EP102A
MCA1
E L E
C T
R
IC
A L
P O
W E
R P
L A
N
L E
V E
L
A
R E
A A
F O
R T
G O
R D
O N
G
A
W
E S
T O
G L E
T H
O R
P E
A V
E N
U E
S A
V A
N N
A H
D
IS
T R
IC
T
S A
V A
N N
A H
G
A
H D
R A
R L
IN
G T
O N
V
IR
G
IN
IA
D A
D A
M
J E
S T
R A
D A
J A
M
U R
R A
Y
L B
A Y
L O
N
F E
B R
U A
R Y
W H
N -1
-R
-3
-3
-0
C
A T
E G
O R
Y C
O D
E
ISSUE FOR CONSTRUCTION
S C
I T
R A
IN
IN
G R
E S
E A
R C
H
N E
T W
O R
K C
E N
T E
R
F Y
P
N
8'4' 16'0
SCALE: 1/8"=1'-0"
1/8" = 1'-0" A1
ELECTRICAL - POWER PLAN - LEVEL 2 - AREA A
NORTH
B C
KEY PLAN
A
GENERAL NOTES
(TYP.)
(TYP.)
KEYNOTES
(TYP.)
1. POWER DISTRIBUTION MODULE (PDM). FLOOR MOUNTED UNDER
RAISED ACCESS FLOOR. WORKSTATION POWER MODULE WILL
BE CONNECTED TO PDM USING PLUG AND PLAY POWER
CABLES. PROVIDE CABLE SLACK FOR WPM LOCATION
FLEXIBILITY.EACH PDM SHALL BE PROVIDED WITH CIRCUITS AS
INDICATED ON PLANS. REFER TO SHEET E-502 FOR
CONNECTION DETAIL.
2. WORKSTATION POWER MODULE (WPM) FLUSH MOUNTED AT
ACCESS FLOOR. PROVIDE (4) DUPLEX RECEPTACLES AT EACH
WPM. REFER TO E-502 FOR CONNECTION DETAIL.
3. REFER TO SHEET E-401 FOR CIRCUITRY IN THIS ROOM.
4. POWER CONNECTION FOR MECHANICAL EQUIPMENT
(ATU,VVR'S). COORDINATE LOCATION WITH MECHANICAL
CONTRACTOR PRIOR TO INSTALLATION.
5. POWER CONNECTION FOR FLAT PANEL DISPLAY.
6. POWER CONNECTION FOR MODULAR FURNITURE.
RECEPTACLES ARE PREWIRED IN FURNITURE. REFER TO SHEET
E-502 FOR CONNECTION DETAIL.
7. PROVIDE WPM WITH NEMA 5-30R RECEPTACLE FOR AV RACK
POWER CONNECTION. VERIFY EXACT NEMA CONFIGURATION
REQUIREMENT.
8. POWER CONNECTION FOR COUNTERTOP KITCHEN EQUIPMENT.
9. UNISTRUT SUPPORT FOR VERTICAL RISERS AS REQUIRED.
10. SEE DETAIL D1/D2 ON SHEET E-405 FOR UPFOLDING PANEL
PARTITION DETAIL.
11. POWER CONNECTION FOR COPIER MACHINE.
12. POWER CONNECTION FOR REFRIGERATOR.
13. POWER CONNECTION FOR MICROWAVE.
14. POWER CONNECTION FOR SIGNAGE. COORDINATE WITH A/V
CONTRACTOR.
15. DASHED LINE INDICATES SECURE AREA BOUNDARY.
16. POWER CONNECTION FOR FIRE SMOKE DAMPER.
17. PROVIDE NEMA TYPE L5-30R RECEPTACLE.
(TYP.)
(TYP.)
(TYP.)
(TYP.)
R
E V
IS
IO
N
/2
/1
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/2
/1
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/2
J
J
J J J J J
J J J
J
J
E-401
C4
M A
T C
H
LI
E : A
1/ E
P
2B
STAIR #2
INSTRUCTOR
PRINT/COPY
CAVE
CORRIDOR
LAB
CLASSROOM
TEL221
ELEV #2
ELEC
STORAGE
MECH
SHAFT
CLASSROOM
CLASSROOM
CORRIDOR
STAFF
BREAK
CONF 4-6
P
STAIR #3
KIOSK
AREA
CORRIDOR
NTR2E1
11 12 13 14 15 16
F
E
D
C
B
NPL2L1
QPL2E1
CLASSROOM
M
MM
M
PDM
PDM
M
M
M
+48"
+48"
+48"
+48"
+48"
+48"
+66"
NPL2E3
PDM
PDM
PDM
PDM
PDM
PDM
PDM
PDM
NPL2E4
NPL2ET1
1 53
3 5
19 21
NPL2E4-1,3,5,7,9,11
NPL2E4-2,4,6,8,10,12,14
NPL2E4-17,19,21,23,25,27
NPL2E4-16,18,20,24,26,28
NPL2E3-1,3,5,7,9,11,13
NPL2E3-2,4,6,8,10,12
NPL2E3-17,19,21,23,25,27,29
NPL2E3-16,18,20,22,24,26
NPL2L1-2,4,6,8
NPL2L1-1,3,5,7
NDL2E1
NPL2E2-31
NPL2E2-30
NPL2E1-29
+48"
M
T
+48"
UPFOLDING PANEL PARTITION
+48"
GFI
NPL2E2-33
NPL2E2-32
NPL2E2
DNTR2E1
M
QPL2E1-20
QPL2E1-22
QPL2E1-29,31,33
M
M
M M
NPL2E2-28
QPL2E1-28
NPL2E4-34,36
NPL2E4-33,35
NPL2E3-30
NPL2E3-33
NPL2E3-34
GFI
+48"
NPL2E2-29
NPL2E1
NPL2E4-30
NPL2E4-32
NPL2E4-37
NPL2E4-13
NPL2E4-15
NPL2E4-31
LPL1M1-12
+48"
NPL2E1-28
+48"
+48"
NPL2E3-14
NPL2E3-15
+48"
+48"
NPL2E3-28
NPL2E3-31
+48"
PDM
PDM
NPL2L1-9
NPL2L1-10
NPL2E4-29
+48"
+48"
+48"
+48"
+48"
+48"
+48" +48"
+48" +48"
+48"
+66"
NPL2E2-34
+66"
NPL2E3-32
A. REFER TO SHEET E-001 AND E-002 FOR SYMBOLS,
ABBREVIATIONS AND ADDITIONAL INSTALLATION
REQUIREMENTS.
B. REFER TO SHEET E-600 SERIES FOR ELECTRICAL ONE LINE
DIAGRAMS.
C. SEE E-701 FOR FEEDER AND TRANSFORMER SCHEDULE.
D. ALL ELECTRICAL EQUIPMENT IS NEW UNLESS NOTED
OTHERWISE.
E. CONDUIT AND WIRE IS SHOWN DIAGRAMMATICALLY. ACTUAL
ROUTING AND REQUIRED NUMBER OF SUPPORTS SHALL BE
DETERMINED BY THE CONTRACTOR.
F. UNLESS CONDUIT ROUTING CLEARLY INDICATES AS SUCH, DO
NOT ROUTE CONDUIT ON OR ABOVE ROOFTOPS WITHOUT
CONSULTING ENGINEER TO DETERMINE ANY POTENTIAL
IMPACT TO RACEWAY OR CONDUCTOR SIZE DUE TO
ADDITIONAL AMBIENT DERATING FOR ROOFTOP INSTALLATION.
G. CONCEAL CONDUITS IN ALL FINISHED AREAS INCLUDING
CONCEALMENT WITHIN MASONRY WALLS WHEN PRESENT.
(EXCEPTION: ELECTRICAL, MECHANICAL, AND JANITOR ROOMS).
H. FLOOR AND FIRE WALL PENETRATIONS MUST BE SEALED WITH
AN APPROVED DESIGN TESTED FIRE STOPPING SYSTEM
APPROPRIATE TO THE PENETRATED WALL TYPE INSTALLED IN
ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS. REFER
TO E-500 SERIES DRAWINGS FOR FIRE PENETRATION DETAIL.
I. WHEN OVERHEAD ELECTRICAL WORK IS EXPOSED: MOUNTING
OF ALL ELECTRICAL WORK/CONDUIT SHALL RUN IN DECK
FLUTES AND/OR TIGHT WITH DECK. CONTRACTOR MAY RUN
CONDUIT UNDER FLOOR AS NECESSARY TO FACILITATE
CONCEALMENT OF CONDUITS.
J. PRIOR TO ROUGH-IN AND FINAL CONNECTION, VERIFY
ELECTRICAL CHARACTERISTICS AND EXACT LOCATION OF THE
EQUIPMENT.
K. INSTALL ALL CONDUITS PARALLEL PERPENDICULAR AND
UNIFORM TO BUILDING ELEMENTS
L. NO MORE THAN 180 DEGREE OF CONDUIT BENDS ARE ALLOWED
IN ANY INTERIOR CONDUIT RUNS.
M. IDENTIFY ALL CONDUIT RUNS WITH MARKER TAPE.
N. WHEN MORE THAN 3 CURRENT CARRYING CONDUCTORS ARE
INSTALLED WITHIN A SINGLE CONDUIT DERATE CONDUCTOR
AMPACITY PER NEC 310.15(B)(3)(a). CONTRACTOR SHALL UPSIZE
CONDUCTORS AS REQUIRED.
O. THE BUSWAY SHALL BE PROVIDED WITH BRACING PER UFC
4-010-01 ATFP REQUIREMENT.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
C:\rvt\2018\10053876-M-MCA1-Central_TSCHNEPF.rvt
6/25/2019 8:45 AM
EP102C
MCA1
E L E
C T
R
IC
A L
P O
W E
R P
L A
N
L E
V E
L
A
R E
A C
F O
R T
G O
R D
O N
G
A
W
E S
T O
G L E
T H
O R
P E
A V
E N
U E
S A
V A
N N
A H
D
IS
T R
IC
T
S A
V A
N N
A H
G
A
H D
R A
R L
IN
G T
O N
V
IR
G
IN
IA
D A
D A
M
J E
S T
R A
D A
J A
M
U R
R A
Y
L B
A Y
L O
N
F E
B R
U A
R Y
W H
N -1
-R
-3
-3
-0
C
A T
E G
O R
Y C
O D
E
ISSUE FOR CONSTRUCTION
S C
I T
R A
IN
IN
G R
E S
E A
R C
H
N E
T W
O R
K C
E N
T E
R
F Y
P
N
8'4' 16'0
SCALE: 1/8"=1'-0"
1/8" = 1'-0" A1
ELECTRICAL - POWER PLAN - LEVEL 2 - AREA C
NORTH
B C
KEY PLAN
A
GENERAL NOTES
KEYNOTES
1. POWER DISTRIBUTION MODULE (PDM). FLOOR MOUNTED UNDER
RAISED ACCESS FLOOR. WORKSTATION POWER MODULE WILL
BE CONNECTED TO PDM USING PLUG AND PLAY POWER
CABLES. PROVIDE CABLE SLACK FOR WPM LOCATION
FLEXIBILITY. EACH PDM SHALL BE PROVIDED WITH CIRCUITS AS
INDICATED ON PLANS. REFER TO SHEET E-502 FOR
CONNECTION DETAIL.
2. WORKSTATION POWER MODULE (WPM) FLUSH MOUNTED AT
ACCESS FLOOR. PROVIDE (4) DUPLEX RECEPTACLES AT EACH
WPM. REFER TO SHEET E-502 FOR CONNECTION DETAIL.
3. REFER TO SHEET E-401 FOR CIRCUITRY IN THIS ROOM.
4. POWER CONNECTION FOR MECHANICAL EQUIPMENT
(ATU,VVR'S). COORDINATE LOCATION WITH MECHANICAL
CONTRACTOR PRIOR TO INSTALLATION.
5. POWER CONNECTION FOR FLAT PANEL DISPLAY.
6. POWER CONNECTION FOR MODULAR FURNITURE.
RECEPTACLES ARE PREWIRED IN FURNITURE.
REFER TO SHEET E-502 FOR CONNECTION DETAIL.
7. PROVIDE WPM WITH NEMA 5-30R RECEPTACLE FOR AV RACK
POWER CONNECTION. VERIFY EXACT EQUIPMENT NEMA
CONFIGURATION REQUIREMENT.
8. POWER CONNECTION FOR COUNTERTOP KITCHEN EQUIPMENT.
9. UNISTRUT SUPPORT FOR VERTICAL RISERS AS REQUIRED.
10. SEE DETAIL D1/D2 ON SHEET E-405 FOR UPFOLDING PANEL
PARTITION DETAIL.
11. POWER CONNECTION FOR REFRIGERATOR.
12. POWER CONNECTION FOR MICROWAVE.
13. POWER CONNECTION FOR COPIER MACHINE.
14. POWER CONNECTION FOR SIGNAGE. COORDINATE WITH A/V
CONTRACTOR.
15. DASHED LINE INDICATES SECURE AREA BOUNDARY.
16. POWER CONNECTION FOR FIRE SMOKE DAMPER.
17. PROVIDE NEMA TYPE L5-30R RECEPTACLE.
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
R
E V
IS
IO
N
/2
/1
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/2
/1
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/2
DN
J
J
J
J
J
J
E-401
A7
M A
T C
H
LI
E : A
1/ E
P
4B
EXECUTIVE
CONFERENCE
ROOM
(35 PN)
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
TOILET
PRIVATE
OFFICE
PRIVATE
OFFICE
COMMANDANT
OPEN
OFFICE
CORRIDOR
COLLABORATION
ELEC
TEL
STAIR #5
PRINT/COPY
MECH
SHAFT
STAIR #4
NPL4W2NPL4W1
NTR4W1
1 2 4 5
F
E
D
C
B
GFI
+48"
+48"
GFI
PDM
BREAK
MM
+48"
+48"
+48"
M
NPL4WT1
PDM
PDM
+48"
+48"
+48"
+48"
QPL4W1
M
M
M
PDM
PDM
NPL4W1-2,4,6
NPL4W2-21
NPL4W1-1,3,5,7
NPL4W1-12,14,16,18,20,22
NPL4W1-9,11,13,15
NPL4W1-24,26,28,30,32,34
NPL4W2-11,13,15
T
7 7
1 1
17 15
+48"
NDL4W1
QPL4W1-12
M
QPL4W1-7
QPL4W1-9
GFI
+48"
QPL4W1-11
+23" +23"
+23"
QPL4W1-16
QPL4W1-18
QPH4W1
QDH4W1
DNTR4W1
M
2 2
4 4
6 6
M
12 12
14 14
26 26
24 28 30 30
32 34 34
M
9 13
11 11
16 18 18
20 22 22
NPL4W2-25
NPL4W2-29
PDM
NPL4W1-19,21,23,25
PDM
NPL4W1-10
NPL4W1-27,29,31
PDM
NPL4W2-10
NPL4W1-17
NPL4W1-8
LPL3E1-3
+102"
+48"
A. REFER TO SHEET E-001 AND E-002 FOR SYMBOLS,
ABBREVIATIONS AND ADDITIONAL INSTALLATION
REQUIREMENTS.
B. REFER TO SHEET E-600 SERIES FOR ELECTRICAL ONE LINE
DIAGRAMS.
C. SEE E-701 FOR FEEDER AND TRANSFORMER SCHEDULE.
D. ALL ELECTRICAL EQUIPMENT IS NEW UNLESS NOTED
OTHERWISE.
E. CONDUIT AND WIRE IS SHOWN DIAGRAMMATICALLY. ACTUAL
ROUTING AND REQUIRED NUMBER OF SUPPORTS SHALL BE
DETERMINED BY THE CONTRACTOR.
F. UNLESS CONDUIT ROUTING CLEARLY INDICATES AS SUCH, DO
NOT ROUTE CONDUIT ON OR ABOVE ROOFTOPS WITHOUT
CONSULTING ENGINEER TO DETERMINE ANY POTENTIAL
IMPACT TO RACEWAY OR CONDUCTOR SIZE DUE TO
ADDITIONAL AMBIENT DERATING FOR ROOFTOP INSTALLATION.
G. CONCEAL CONDUITS IN ALL FINISHED AREAS INCLUDING
CONCEALMENT WITHIN MASONRY WALLS WHEN PRESENT.
(EXCEPTION: ELECTRICAL, MECHANICAL, AND JANITOR ROOMS).
H. FLOOR AND FIRE WALL PENETRATIONS MUST BE SEALED WITH
AN APPROVED DESIGN TESTED FIRE STOPPING SYSTEM
APPROPRIATE TO THE PENETRATED WALL TYPE INSTALLED IN
ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS. REFER
TO E-500 SERIES DRAWINGS FOR FIRE PENETRATION DETAIL.
I. WHEN OVERHEAD ELECTRICAL WORK IS EXPOSED: MOUNTING
OF ALL ELECTRICAL WORK/CONDUIT SHALL RUN IN DECK
FLUTES AND/OR TIGHT WITH DECK. CONTRACTOR MAY RUN
CONDUIT UNDER FLOOR AS NECESSARY TO FACILITATE
CONCEALMENT OF CONDUITS.
J. PRIOR TO ROUGH-IN AND FINAL CONNECTION, VERIFY
ELECTRICAL CHARACTERISTICS AND EXACT LOCATION OF THE
EQUIPMENT.
K. INSTALL ALL CONDUITS PARALLEL PERPENDICULAR AND
UNIFORM TO BUILDING ELEMENTS
L. NO MORE THAN 180 DEGREE OF CONDUIT BENDS ARE ALLOWED
IN ANY INTERIOR CONDUIT RUNS.
M. IDENTIFY ALL CONDUIT RUNS WITH MARKER TAPE.
N. WHEN MORE THAN 3 CURRENT CARRYING CONDUCTORS ARE
INSTALLED WITHIN A SINGLE CONDUIT DERATE CONDUCTOR
AMPACITY PER NEC 310.15(B)(3)(a). CONTRACTOR SHALL UPSIZE
CONDUCTORS AS REQUIRED.
O. THE BUSWAY SHALL BE PROVIDED WITH BRACING PER UFC
4-010-01 ATFP REQUIREMENT.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
C:\rvt\2018\10053876-M-MCA1-Central_TSCHNEPF.rvt
6/25/2019 8:45 AM
EP104A
MCA1
E L E
C T
R
IC
A L
P O
W E
R P
L A
N
L E
V E
L
A
R E
A A
F O
R T
G O
R D
O N
G
A
W
E S
T O
G L E
T H
O R
P E
A V
E N
U E
S A
V A
N N
A H
D
IS
T R
IC
T
S A
V A
N N
A H
G
A
H D
R A
R L
IN
G T
O N
V
IR
G
IN
IA
D A
D A
M
J E
S T
R A
D A
J A
M
U R
R A
Y
L B
A Y
L O
N
F E
B R
U A
R Y
W H
N -1
-R
-3
-3
-0
C
A T
E G
O R
Y C
O D
E
ISSUE FOR CONSTRUCTION
S C
I T
R A
IN
IN
G R
E S
E A
R C
H
N E
T W
O R
K C
E N
T E
R
F Y
P
N
8'4' 16'0
SCALE: 1/8"=1'-0"
1/8" = 1'-0" A1
ELECTRICAL - POWER PLAN - LEVEL 4 - AREA A
NORTH
B C
KEY PLAN
A
GENERAL NOTES
KEYNOTES
(TYP.)
(TYP.)
(TYP.)
1. POWER DISTRIBUTION MODULE (PDM). FLOOR MOUNTED UNDER
RAISED ACCESS FLOOR. WORKSTATION POWER MODULE WILL
BE CONNECTED TO PDM USING PLUG AND PLAY POWER
CABLES. PROVIDE CABLE SLACK FOR WPM LOCATION
FLEXIBILITY. EACH PDM SHALL BE PROVIDED WITH CIRCUITS AS
INDICATED ON DRAWING. REFER TO SHEET E-502 FOR
CONNECTION DETAIL.
2. WORKSTATION POWER MODULE (WPM) FLUSH MOUNTED AT
ACCESS FLOOR. PROVIDE (4) DUPLEX RECEPTACLES AT EACH
WPM. REFER TO SHEET E-502 FOR CONNECTION DETAIL.
3. REFER TO SHEET E-401 FOR CIRCUITRY IN THIS ROOM.
4. POWER CONNECTION FOR MECHANICAL EQUIPMENT
(ATU,VVR'S).COORDINATE LOCATION WITH MECHANICAL
CONTRACTOR PRIOR TO INSTALLATION.
5. POWER CONNECTION FOR FLAT PANEL DISPLAY. COORDINATE
LOCATION WITH A/V CONTRACTOR PRIOT TO INSTALLATION.
6. POWER CONNECTION FOR MODULAR FURNITURE.
RECEPTACLES ARE PREWIRED IN FURNITURE.
REFER TO SHEET E-502 FOR CONNECTION DETAIL.
7. PROVIDE WPM WITH NEMA 5-30R RECEPTACLE FOR AV RACK
POWER CONNECTION. VERIFY EXACT EQUIPMENT NEMA
CONFIGURATION REQUIREMENTS.
8. POWER CONNECTION FOR COPIER MACHINE.
9. POWER CONNECTION FOR SIGNAGE. COORDINATE WITH A/V
CONTRACTOR.
10. UNISTRUT SUPPORT FOR VERTICAL RISERS AS REQUIRED.
11. POWER CONNECTION FOR REFRIGERATOR.
12. POWER CONNECTION FOR MICROWAVE.
13. DASHED LINE INDICATES SECURE AREA BOUNDARY.
14. POWER CONNECTION FOR FIRE SMOKE DAMPER.
(TYP.)
(TYP.)
(TYP.)
R
E V
IS
IO
N
/2
/1
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/2
/1
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/2
J J
JJ
J
J
E-401
C7
M A
T C
H
LI
E : A
1/ E
P
4B
STAIR #2
ELEV #2
STORAGE
MECH
SHAFT
TEL
ELEC
INSTRUCTOR
LAB
LAB
RESOURCE
CENTER
NPL4E2
NPL4E1
NTR4E1
11 12 13 14 15 16
F
E
D
C
B
CAVE
SUPPLY
STORAGE
PRINT/COPY
NPL4L1-1
NPL4L1-2
NPL4L1-3
NPL4L1-4
GFI
+48"
QPL4E1
QDH4E1
M
PDM
PDM
+48"
QPH4E1
NPL4ET1
PDM
PDM
PDM
PDM
PDM
+48"
M
M
M
NPL4E2-23
T
+48"
PDM
PDM
1 5
2 6
NPL4L1-4-2,4,6,8,10
+48"
PDM
PDM
1 5 5
NPL4L1-2-2,4,6,8,10
NPL4L1-2-1,3,5,7,9,11,15
NPL4L1-4-1,3,5,7,9,11,13
LAB
LAB
NPL4L1-1-2,4,6,8,10,12,14
NPL4L1-1-3,5,7,9 NPL4L1-3-1,3,5,7,9
NPL4L1-3-2,4,8,10,12,14
NPL4E2-11,13,15
NPL4E2-1,3,5
PDM
NPL4E2-2,4,6,8,10
NPL4E2-12,14,16,18,20,22
1 3 5 5
1 7
4 6
15 13
12 12
8 8
6 6
4 4
6 8
M
QTR4E1
+48"
M
NDL4E1
T
M
+48"
QPL4E1-18
QPL4E1-20
NPL4L1-1-13
NPL4L1-2-12
DNTR4E1
M
M
M
13 3
NPL4E2-24
M
NPL4E2-19
NPL4E2-21
NPL4E2-17
NPL4L1-4-12
NPL4L1-3-13
NPL4E2-9
NPL4E2-7
LPL3E1-4
+48"
+48"
NPL4L1-4-15
+48"
NPL4L1-3-11
+48"
NPL4L1-1-11
NPL4L1-2-13
RF
RF
RF
RF
LACTATION
CORRIDOR
CORRIDOR
CORRIDOR
LAB
+48"
+48" +48"
+48"
+48"+48"
+48"
+48"
A. REFER TO SHEET E-001 AND E-002 FOR SYMBOLS,
ABBREVIATIONS AND ADDITIONAL INSTALLATION
REQUIREMENTS.
B. REFER TO SHEET E-600 SERIES FOR ELECTRICAL ONE LINE
DIAGRAMS.
C. SEE E-701 FOR FEEDER AND TRANSFORMER SCHEDULE.
D. ALL ELECTRICAL EQUIPMENT IS NEW UNLESS NOTED
OTHERWISE.
E. CONDUIT AND WIRE IS SHOWN DIAGRAMMATICALLY. ACTUAL
ROUTING AND REQUIRED NUMBER OF SUPPORTS SHALL BE
DETERMINED BY THE CONTRACTOR.
F. UNLESS CONDUIT ROUTING CLEARLY INDICATES AS SUCH, DO
NOT ROUTE CONDUIT ON OR ABOVE ROOFTOPS WITHOUT
CONSULTING ENGINEER TO DETERMINE ANY POTENTIAL
IMPACT TO RACEWAY OR CONDUCTOR SIZE DUE TO
ADDITIONAL AMBIENT DERATING FOR ROOFTOP INSTALLATION.
G. CONCEAL CONDUITS IN ALL FINISHED AREAS INCLUDING
CONCEALMENT WITHIN MASONRY WALLS WHEN PRESENT.
(EXCEPTION: ELECTRICAL, MECHANICAL, AND JANITOR ROOMS).
H. FLOOR AND FIRE WALL PENETRATIONS MUST BE SEALED WITH
AN APPROVED DESIGN TESTED FIRE STOPPING SYSTEM
APPROPRIATE TO THE PENETRATED WALL TYPE INSTALLED IN
ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS. REFER
TO E-500 SERIES DRAWINGS FOR FIRE PENETRATION DETAIL.
I. WHEN OVERHEAD ELECTRICAL WORK IS EXPOSED: MOUNTING
OF ALL ELECTRICAL WORK/CONDUIT SHALL RUN IN DECK
FLUTES AND/OR TIGHT WITH DECK. CONTRACTOR MAY RUN
CONDUIT UNDER FLOOR AS NECESSARY TO FACILITATE
CONCEALMENT OF CONDUITS.
J. PRIOR TO ROUGH-IN AND FINAL CONNECTION, VERIFY
ELECTRICAL CHARACTERISTICS AND EXACT LOCATION OF THE
EQUIPMENT.
K. INSTALL ALL CONDUITS PARALLEL PERPENDICULAR AND
UNIFORM TO BUILDING ELEMENTS
L. NO MORE THAN 180 DEGREE OF CONDUIT BENDS ARE ALLOWED
IN ANY INTERIOR CONDUIT RUNS.
M. IDENTIFY ALL CONDUIT RUNS WITH MARKER TAPE.
N. WHEN MORE THAN 3 CURRENT CARRYING CONDUCTORS ARE
INSTALLED WITHIN A SINGLE CONDUIT DERATE CONDUCTOR
AMPACITY PER NEC 310.15(B)(3)(a). CONTRACTOR SHALL UPSIZE
CONDUCTORS AS REQUIRED.
O. THE BUSWAY SHALL BE PROVIDED WITH BRACING PER UFC
4-010-01 ATFP REQUIREMENT.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
C:\rvt\2018\10053876-M-MCA1-Central_TSCHNEPF.rvt
6/25/2019 8:45 AM
EP104C
MCA1
E L E
C T
R
IC
A L
P O
W E
R P
L A
N
L E
V E
L
A
R E
A C
F O
R T
G O
R D
O N
G
A
W
E S
T O
G L E
T H
O R
P E
A V
E N
U E
S A
V A
N N
A H
D
IS
T R
IC
T
S A
V A
N N
A H
G
A
H D
R A
R L
IN
G T
O N
V
IR
G
IN
IA
D A
D A
M
J E
S T
R A
D A
J A
M
U R
R A
Y
L B
A Y
L O
N
F E
B R
U A
R Y
W H
N -1
-R
-3
-3
-0
C
A T
E G
O R
Y C
O D
E
ISSUE FOR CONSTRUCTION
S C
I T
R A
IN
IN
G R
E S
E A
R C
H
N E
T W
O R
K C
E N
T E
R
F Y
P
N
8'4' 16'0
SCALE: 1/8"=1'-0"
1/8" = 1'-0" A1
ELECTRICAL - POWER PLAN - LEVEL 4 - AREA C
NORTH
B C
KEY PLAN
A
GENERAL NOTES
KEYNOTES
(TYP.)
(TYP.)
4(TYP.)
1. POWER DISTRIBUTION MODULE (PDM). FLOOR MOUNTED UNDER
RAISED ACCESS FLOOR. WORKSTATION POWER MODULE WILL
BE CONNECTED TO PDM USING PLUG AND PLAY POWER
CABLES. PROVIDE CABLE SLACK FOR WPM LOCATION
FLEXIBILITY. EACH PDM SHALL BE PROVIDED WITH CIRCUITS AS
INDICATED ON DRAWING. REFER TO SHEET E-502 FOR
CONNECTION DETAIL.
2. WORKSTATION POWER MODULE (WPM) FLUSH MOUNTED AT
ACCESS FLOOR. PROVIDE (4) DUPLEX RECEPTACLES AT EACH
WPM. REFER TO SHEET E-502 FOR CIRCUITRY IN THIS ROOM.
3. REFER TO SHEET E-401 FOR CIRCUITRY IN THIS ROOM.
4. POWER CONNECTION FOR MECHANICAL EQUIPMENT
(ATU,VVR'S). COORDINATE LOCATION WITH MECHANICAL
CONTRACTOR PRIOR TO INSTALLATION.
5. POWER CONNECTION FOR FLAT PANEL DISPLAY.
6. POWER CONNECTION FOR MODULAR FURNITURE.
RECEPTACLES ARE PREWIRED IN FURNITURE.
REFER TO SHEET E-502 FOR CONNECTION DETAIL.
7. PROVIDE WPM WITH NEMA 5-30R RECEPTACLE FOR AV RACK
POWER CONNECTION. VERIFY EXACT EQUIPMENT NEMA
CONFIGURATION REQUIREMENTS.
8. UNISTRUT SUPPORT FOR VERTICAL RISERS AS REQUIRED.
9. POWER CONNECTION FOR SIGNAGE. COORDINATE WITH A/V
CONTRACTOR.
10. POWER CONNECTION FOR COPIER MACHINE.
11. DASHED LINE INDICATES SECURE AREA BOUNDARY.
12. POWER CONNECTION FOR FIRE SMOKE DAMPER.
13. RF FILTER LOCATION.
(TYP.)
(TYP.)
9 (TYP.)
(TYP.)
9(TYP.)
R
E V
IS
IO
N
/2
/1
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/2
/1
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/2
J
JJ
JJ
J
J
E
ELEC
TEL
NPL1W1
LPH1W1
NTR1W1
NPH1W1
NDH1W1
NPL1W4
NPL1W3
NPL1W2
NPL1WT1
NPL1WT1-10
NPL1WT1-12
QPL1W1
NDL1W1
QPL1W1-4
HUM-5
FCU-2
QPL1W1-2
FCU-9
T
M M
M
NPL1WT1-1
NPL1WT1-3
NPL1WT1-5
NPL1WT1-7
NPL1WT1-2
NPL1WT1-4
NPL1WT1-6
NPL1WT1-8
NPL1WT1-9
NPL1WT1-11
NPL1WT1-13
NPL1WT1-15
QPL1W1-6
LPL1M1-11
12 13
E
TEL
ELEC
NPL2E2
NPL2E1
NTR2E1
QPL2E1
NPL2E4
NPL2E3
NPL2ET1
NPL2ET1-10
NPL2ET1-12
NDL2E1
FCU-3 HUM-6
QPL2E1-24
DNTR2E1
T
QPL2E1-26
QPL2E1-28
FCU-10
MM
M
QPL2E1-35
NPL2ET1-1
NPL2ET1-3
NPL2ET1-5
NPL2ET1-7
NPL2ET1-2
NPL2ET1-4
NPL2ET1-6
NPL2ET1-8
NPL2ET1-9
NPL2ET1-11
NPL2ET1-13
NPL2ET1-15
E
ELEC
TEL
NPL2W1
NPL2W3
NTR2W1
NPL2W4
NPL2W2
NPL2WT1
NPL2WT1-10
NPL2WT1-12
NDL2W1
T
QPL2W1-2
FCU-11
QPL2W1-4
FCU-4
HUM-7
QPL2W1
M
MM
NPL2W5
DNTR2W1
NPL2WT1-1
NPL2WT1-3
NPL2WT1-5
NPL2WT1-7
NPL2WT1-2
NPL2WT1-4
NPL2WT1-6
NPL2WT1-8
NPL2WT1-9
NPL2WT1-11
NPL2WT1-13
NPL2WT1-15
LPL1M1-13
QPL2W1-6
12 13
E
TEL
ELEC
NPL3E1
NPL3E2
LPH3E1
NTR3E1
QPL3E1
NPH3E1
NPL3E4
NPL3E3
NPL3ET1
NPL3ET1-10
NPL3ET1-12
DNTR3E1
T
NDL3E1
QPL3E1-28
FCU-5 HUM-8 FCU-12
QPL3E1-26
QPL3E1-24
M M
M
LT
R
3E
LPL3E1
QPL3E1-29
NPL3ET1-1
NPL3ET1-3
NPL3ET1-5
NPL3ET1-7
NPL3ET1-2
NPL3ET1-4
NPL3ET1-6
NPL3ET1-8
NPL3ET1-9
NPL3ET1-11
NPL3ET1-13
NPL3ET1-15
E
ELEC
TEL
NPL3W2
NPL3W1
LPH3W1
NTR3W1
NPH3W1
NPL3W4
NPL3W3
NPL3WT1
NPL3WT1-10
NPL3WT1-12
QPL3W1-2
FCU-13 FCU-6
HUM-9
QPL3W1-4
DNTR3W1
NDL3W1
QPL3W1
T
M M
M
NPL3W5
NPL3WT1-1
NPL3WT1-3
NPL3WT1-5
NPL3WT1-7
NPL3WT1-2
NPL3WT1-4
NPL3WT1-6
NPL3WT1-8
NPL3WT1-9
NPL3WT1-11
NPL3WT1-13
NPL3WT1-15
LPL3E1-5
QPL3W1-6
12 13
E
TEL
ELEC
NPL4E2
NPL4E1
NTR4E1
QDH4E1
QPL4E1
QPH4E1
NPL4ET1
NPL4ET1-10
NPL4ET1-12
HUM-10
T
T QTR4E1
DNTR4E1
NDL4E1
QPL4E1-26
QPL4E1-24
FCU-7
QPL4E1-28
FCU-14
M M
M
QPL4E1-36
NPL4ET1-1
NPL4ET1-3
NPL4ET1-5
NPL4ET1-7
NPL4ET1-2
NPL4ET1-4
NPL4ET1-6
NPL4ET1-8
NPL4ET1-9
NPL4ET1-11
NPL4ET1-13
NPL4ET1-15
E
ELEC
TEL
NPL4W2NPL4W1
NTR4W1
NPL4WT1
QDH4W1
NPL4WT1-10
NPL4WT1-12
QPL4W1
QPH4W1
HUM-11DNTR4W1
T
NDL4W1
FCU-15
QPL4W1-6 QPL4W1-8
FCU-8
M M
M
NPL4WT1-1
NPL4WT1-3
NPL4WT1-5
NPL4WT1-7
NPL4WT1-2
NPL4WT1-4
NPL4WT1-6
NPL4WT1-8
NPL4WT1-9
NPL4WT1-11
NPL4WT1-13
NPL4WT1-15
LPL3E1-7
QPL4W1-10
E
TEL
NPL1ET1
NPL1ET1-10
NPL1ET1-14
QPL1M1-30
QPL1M1-28
FCU-1 HUM-4
M M
NPL1ET1-1
NPL1ET1-3
NPL1ET1-5
NPL1ET1-7
NPL1ET1-2
NPL1ET1-4
NPL1ET1-6
NPL1ET1-8
NPL1ET1-9
NPL1ET1-11
NPL1ET1-13
NPL1ET1-15
NPL1ET1-12
NPL1ET1-16
A. REFER TO SHEET E-001 AND E-002 FOR SYMBOLS,
ABBREVIATIONS AND ADDITIONAL INSTALLATION
REQUIREMENTS.
B. SEE E-601 THROUGH E-604 FOR ELECTRICAL ONE LINE
DIAGRAMS.
C. REFER TO SHEET E-701 FOR FEEDER AND TRANSFORMER
SCHEDULES.
D. ALL ELECTRICAL EQUIPMENT IS NEW UNLESS NOTED
OTHERWISE.
E
ELEV #2
MACH
ROOM
GFI
GFI
GFI
GFI
QDH4E1-5
QPL4E1-34
QPL4E1-29
WP
AC-2
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
C:\rvt\2018\10053876-M-MCA1-Central_TSCHNEPF.rvt
6/25/2019 8:44 AM
E-401
MCA1
E L E
C T
R
IC
A L E
N L A
R G
E D
P L A
N
F O
R T
G O
R D
O N
G
A
W
E S
T O
G L E
T H
O R
P E
A V
E N
U E
S A
V A
N N
A H
D
IS
T R
IC
T
S A
V A
N N
A H
G
A
H D
R A
R L
IN
G T
O N
V
IR
G
IN
IA
D A
D A
M
J E
S T
R A
D A
J A
M
U R
R A
Y
L B
A Y
L O
N
F E
B R
U A
R Y
W H
N -1
-R
-3
-3
-0
C
A T
E G
O R
Y C
O D
E
ISSUE FOR CONSTRUCTION
S C
I T
R A
IN
IN
G R
E S
E A
R C
H
N E
T W
O R
K C
E N
T E
R
F Y
P
N
1/4" = 1'-0" A1
ENLARGED ELEC RM 171/ TEL RM 172 - LEVEL 1
1/4" = 1'-0" C4
ENLARGED ELEC RM 224 / TEL RM 223 - LEVEL 2
1/4" = 1'-0"
C1
ENLARGED ELEC RM 272 / TEL RM 273 - LEVEL 2
1/4" = 1'-0" E4
ENLARGED ELEC RM 324 / TEL RM 323 - LEVEL 3
1/4" = 1'-0"
E1
ENLARGED ELEC RM 372 / TEL RM 373 - LEVEL 3
1/4" = 1'-0" C7
ENLARGED ELEC RM 424 / TEL RM 423 - LEVEL 4
1/4" = 1'-0" A7
ENLARGED ELEC RM 473 / TEL RM 474 - LEVEL 4
1/4" = 1'-0"
A4
ENLARGED TEL RM 125 - LEVEL 1
1. POWER CONNECTION FOR IT EQUIPMENT RACK. COORDINATE
WITH TELECOM CONTRACTOR.
2. POWER CONNECTION FOR ELEVATOR.
3. POWER CONNECTION FOR ELEVATOR CAB LIGHTING.
4. LOCATION FOR CONDUIT RISER PENETRATION.
5. 30A, 1P NON-FUSED LOCKABLE DISCONNECT SWITCH FOR
SECURITY PANEL POWER CONNECTION. REFER TO DETAIL
D6/TY504 FOR SECURITY EQUIPMENT CABINET ELEVATION.
6. EPO PUSHBUTTON.
7. POWER CONNECTION FOR HVAC CONTROL PANEL.
8. POWER CONNECTION FOR FIRE ALARM CONTROL PANEL
(RMCP). PROVIDE LOCKABLE CIRCUIT BREAKER IN POWER
PANEL INDICATED.
9. 30A, 1P NON-FUSED LOCKABLE DISCONNECT SWITCH FOR
SECURITY RACK.
KEYNOTES
GENERAL NOTES
1 1
0 2' 4' 8'
SCALE: 1/4" = 1'-0"
(TYP.)(TYP.)
(TYP.)
(TYP.)
(TYP.) (TYP.)
1/4" = 1'-0" E7
ENLARGED ELEV#2 MACH RM 621 - ROOF
6 6
6 6 6
(TYP.)(TYP.)
8 8
5 5
R
E V
IS
IO
N
/2
/1
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/2
/1
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/2
J
VFD
10 11
12 13
E
D
SPPN
HUM-3HUM-2
HUM-1
NPL1M2-7
NPL1M2-3
NPL1M2-5
U B
D 1M
1- A
U B
D 1M
2- B
U B
D 1M
2- B
U B
D 1M
1- A
U B
D 1M
3- A
1B
U B
D 1M
4- B
1B
U B
D 1M
6- B
2B
U B
D 1M
5- A
2B
U B
D 1M
7- A
U B
D 1M
8- B
U B
D 1M
8- B
2B
U B
D 1M
7- A
2B
U B
D 1M
9- A
U B
D 1M
-B
U B
D 1M
-B
U B
D 1M
9- A
U B
D 1M
-A
1B
U B
D 1M
-B
1B
U B
D 1M
-B
U B
D 1M
-A
U B
D 1M
-A
U B
D 1M
-B
U B
D 1M
-B
2B
U B
D 1M
-A
2B
U B
D 1M
-A
1B
U B
D 1M
-B
1B
U B
D 1M
-B
2B
U B
D 1M
-A
2B
U B
D 1M
-A
1B
U B
D 1M
-B
1B
U B
D 1M
-B
2B
U B
D 1M
-A
2B U
B D
1M
-A 2A
U B
D 1M
-B
2A
U B
D 1M
-B
1A
U B
D 1M
-A
1A
U B
D 1M
-A
2A
U B
D 1M
-B
2A
U B
D 1M
-B
1A
U B
D 1M
-A
1A
U B
D 1M
-A
2A
U B
D 1M
-B
2A
U B
D 1M
-B
1A
U B
D 1M
-A
1A
U B
D 1M
7- A
2A
U B
D 1M
8- B
2A
U B
D 1M
5- A
2A
U B
D 1M
6- B
2A
U B
D 1M
4- B
1A
U B
D 1M
3- A
1A
SPPN
EDL1M2-3
EDL1M2-1
QPL1M1-35,37
QPL1M1-36,38
QPL1M1-39,41
LPL1M1-9
UPL1M1
A. REFER TO SHEET E-001 AND E-002 FOR SYMBOLS,
ABBREVIATIONS AND ADDITIONAL INSTALLATION
REQUIREMENTS.
B. REFER TO SHEET E-600 SERIES FOR ELECTRICAL ONE LINE
DIAGRAMS.
C. SEE E-701 FOR FEEDER AND TRANSFORMER SCHEDULE.
D. ALL ELECTRICAL EQUIPMENT IS NEW UNLESS NOTED
OTHERWISE.
E. CONDUIT AND WIRE IS SHOWN DIAGRAMMATICALLY. ACTUAL
ROUTING AND REQUIRED NUMBER OF SUPPORTS SHALL BE
DETERMINED BY THE CONTRACTOR.
F. UNLESS CONDUIT ROUTING CLEARLY INDICATES AS SUCH, DO
NOT ROUTE CONDUIT ON OR ABOVE ROOFTOPS WITHOUT
CONSULTING ENGINEER TO DETERMINE ANY POTENTIAL
IMPACT TO RACEWAY OR CONDUCTOR SIZE DUE TO
ADDITIONAL AMBIENT DERATING FOR ROOFTOP INSTALLATION.
G. CONCEAL CONDUITS IN ALL FINISHED AREAS INCLUDING
CONCEALMENT WITHIN MASONRY WALLS WHEN PRESENT.
(EXCEPTION: ELECTRICAL, MECHANICAL, AND JANITOR ROOMS).
H. FLOOR AND FIRE WALL PENETRATIONS MUST BE SEALED WITH
AN APPROVED DESIGN TESTED FIRE STOPPING SYSTEM
APPROPRIATE TO THE PENETRATED WALL TYPE INSTALLED IN
ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS. REFER
TO E-500 SERIES DRAWINGS FOR FIRE PENETRATION DETAIL.
I. WHEN OVERHEAD ELECTRICAL WORK IS EXPOSED: MOUNTING
OF ALL ELECTRICAL WORK/CONDUIT SHALL RUN IN DECK
FLUTES AND/OR TIGHT WITH DECK. CONTRACTOR MAY RUN
CONDUIT UNDER FLOOR AS NECESSARY TO FACILITATE
CONCEALMENT OF CONDUITS.
J. PRIOR TO ROUGH-IN AND FINAL CONNECTION, VERIFY
ELECTRICAL CHARACTERISTICS AND EXACT LOCATION OF THE
EQUIPMENT.
K. INSTALL ALL CONDUITS PARALLEL PERPENDICULAR AND
UNIFORM TO BUILDING ELEMENTS
L. NO MORE THAN 180 DEGREE OF CONDUIT BENDS ARE ALLOWED
IN ANY INTERIOR CONDUIT RUNS.
M. IDENTIFY ALL CONDUIT RUNS WITH MARKER TAPE.
N. WHEN MORE THAN 3 CURRENT CARRYING CONDUCTORS ARE
INSTALLED WITHIN A SINGLE CONDUIT DERATE CONDUCTOR
AMPACITY PER NEC 310.15(B)(3)(a). CONTRACTOR SHALL UPSIZE
CONDUCTORS AS REQUIRED.
O. THE BUSWAY SHALL BE PROVIDED WITH BRACING PER UFC
4-010-01 ATFP REQUIREMENT.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
C:\rvt\2018\10053876-M-MCA1-Central_TSCHNEPF.rvt
6/26/2019 8:17 AM
E-402
MCA1
E L E
C T
R
IC
A L E
N L A
R G
E D
P L A
N
F O
R T
G O
R D
O N
G
A
W
E S
T O
G L E
T H
O R
P E
A V
E N
U E
S A
V A
N N
A H
D
IS
T R
IC
T
S A
V A
N N
A H
G
A
H D
R A
R L
IN
G T
O N
V
IR
G
IN
IA
D A
D A
M
J E
S T
R A
D A
J A
M
U R
R A
Y
L B
A Y
L O
N
F E
B R
U A
R Y
W H
N -1
-R
-3
-3
-0
C
A T
E G
O R
Y C
O D
E
ISSUE FOR CONSTRUCTION
S C
I T
R A
IN
IN
G R
E S
E A
R C
H
N E
T W
O R
K C
E N
T E
R
F Y
P
N
1/4" = 1'-0" A1
ELECTRICAL ENLARGED SPPN/ELECTRICAL ROOM
1. 400AMP, 120/208V, 3P,4W BUSDUCT. SUSPENDED FROM CEILING
WITH UNISTRUCT SUPPORT.
2. EPO PUSHBUTTON.
3. FEEDER SIZE 10Y. ROUTE TO RACKS INDICATED AND PROVIDE
WITH BUS PLUG PER BUSWAY SCHEDULE.
4. FOR IRC DEDICATED FOR RACKS ON EMERGENCY POWER.
5. POWER CONNECTION FOR FIRE SMOKE DAMPER.
6. SEE SHEET E-702 FOR SPPN BUSWAY SCHEDULE FOR BUSDUCT
AND BUS PLUG SIZES.
7. PROVIDE 30A, 2 POLE DISCONNECT SWITCH FOR HUMIDIFIER.
8. PROVIDE A EMERGENCY POWER OFF (EPO) PANEL FOR DATA
CENTER RACK POWER.
KEYNOTES GENERAL NOTES
0 2' 4' 8'
SCALE: 1/4" = 1'-0"
1 (TYP.)
3 TYP. OF 2
4 TYP. OF 2
7 7
R
E V
IS
IO
N
/2
/1
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/2
/1
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/2
P
A R
E
S P
A R
E
S P
A C
E
VFD VFD
S P
A R
E
S P
A R
E
VFD VFD
S P
A C
E
VFD VFD
S P
A R
E
S P
A C
E
S P
A R
E
S P
A C
E
S P
A C
E
S P
A C
E
S P
A R
E
S P
A R
E
LEVEL 3
LEVEL 4
LEVEL2
LEVEL1
LPH1M1 (LIFE SAFETY)
60A, MCB
277/480V, 3P, 4W, 25kAIC
30A 3P
60A 3P
LPH1W1
60A MCB
480Y/277V 3P,4W
LPH1M2
60A MCB
480Y/277V 3P,4W
LPH3W1
60A MCB
480Y/277V 3P,4W
UQDH1M1
200A, MCB
277/480V, 3P, 4W, 10kACI
200A 3P
30A 3P
60A 3P
60A 3P
60A 3P
LVR1M1
30KVA, LTG. INVERTER
(LIFE SAFETY)
277/480V,3P,4W
W/90 MINUTE BATTERY
BACKUP
30A 3P
30A 3P a d
30A 3P
LPH3E1
60A MCB
480Y/277V 3P,4W
30A 3P
60A 3P
60A 3P
4Y 3Y 4Y 4Y
CWP-3
SEC. CHILL
WTR. PUMP
25HP
CWP-4
(STANDBY)
SEC. CHILL
WTR. PUMP
25HP
5M
SEE E-601 FOR
CONTINUATION
SEE E-604 FOR
CONTINUATION
6Y
100A 3P
UTR1M21
T112.5 (ISOLATION)
480V-480V
QDH4E1
MECHANICAL DISTRIBUTION BOARD
800A, 277/480V, 3PH, 4W, 65kAIC
800A 3P
100A 3P
150A 3P
DOAS-02s
AIR SYS.
SUPPLY
60HP
DOAS-02e
AIR SYS.
EXHAUST
40HP
225A 3P
QPL4E1
300A MCB
208Y/120V 3P,4W
QTR4E1
T75K 480V-120/208V 3P,4W
QPH4E1
225A MCB
208Y/120V 3P,4W
22Y 10M 7M
PASS
ELEVATOR-1
90A 3P
QDH4W1
MECHANICAL DISTRIBUTION BOARD
800A, 277/480V, 3PH, 4W, 35kAIC
800A 3P
100A 3P
DOAS-01s
AIR SYS.
SUPPLY
60HP
DOAS-01e
AIR SYS.
EXHAUST
40HP
7M
150A 3P
90A 3P h
FREIGHT
ELEVATOR
100A 3P f
80Y
5M
SEE E-601 FOR
CONTINUATION
SEE E-601 FOR
CONTINUATION
QPH4W1
100A MCB
208Y/120V 3P,4W
100A 3P
60A 3P
10Y9 9
PASS
ELEV.-2
110A 3P
30A 3P
80Y
5M 5M
BATTERY
90MIN @100%
LOADING EOL
6Y
100A 3P
60A 3P
SPD
30A 3P
SHUNT
TRIP
SHUNT
TRIP
SHUNT
TRIP
LPL1M1
60A MCB
208Y/120V 3P,4W
LTR1M1
T15K 480V-120/208V 3P,4W
30A 3P
LPL3E1
60A MCB
208Y/120V 3P,4W
LTR3E1
T15K 480V-120/208V 3P,4W
90A,3P 90A,3P 110A,3P
10M
SPD
30A 3P
SPD SPD
SPD SPD
SPD
SPD
3Y
3Y
3Y
SPD
30A 3P
3Y
SPD
30A 3P
3Y
A. REFER TO SHEET E-001 AND E-002 FOR SYMBOLS,
ABBREVIATIONS AND ADDITIONAL INSTALLATION
REQUIREMENTS.
B. REFER TO SHEET E-701 FOR FEEDER, MOTOR STARTER AND
TRANSFORMER SCHEDULES.
C. FOR TRANSFORMER PRIMARY AND SECONDARY FEEDER SIZES,
REFER TO TRANSFORMER SCHEDULE ON SHEET E-701.
D. PROVIDE 100% RATED BREAKERS FOR ALL BREAKERS RATED
400A AND LARGER.
E. FOR ALL PANELBOARDS AND DISTRIBUTION BOARDS SHOWN
WITH SURGE PROTECTIVE DEVICES (SPDS) CONNECTED FIELD
LOCATE SPD ABOVE OR BELOW EQUIPMENT
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
C:\rvt\2018\10053876-M-MCA1-Central_TSCHNEPF.rvt
6/25/2019 8:44 AM
E-602
MCA1
E L E
C T
R
IC
A L O
N E
L
IN
E D
IA
G
R A
M
F O
R T
G O
R D
O N
G
A
W
E S
T O
G L E
T H
O R
P E
A V
E N
U E
S A
V A
N N
A H
D
IS
T R
IC
T
S A
V A
N N
A H
G
A
H D
R A
R L
IN
G T
O N
V
IR
G
IN
IA
D A
D A
M
J E
S T
R A
D A
J A
M
U R
R A
Y
L B
A Y
L O
N
F E
B R
U A
R Y
W H
N -1
-R
-3
-3
-0
C
A T
E G
O R
Y C
O D
E
ISSUE FOR CONSTRUCTION
S C
I T
R A
IN
IN
G R
E S
E A
R C
H
N E
T W
O R
K C
E N
T E
R
F Y
P
N
NTS
A1
ELECTRICAL - ONE LINE DIAGRAM
KEYNOTES
GENERAL NOTES
1. FEEDERS ARE UPSIZE TO MITIGATE VOLTAGE DROP. IN LIEU
OF #10 GROUNDING SPECIFIED ON THE FEEDER SCHEDULE.
PROVIDE #8 GROUNDING.
R
E V
IS
IO
N
/2
/1
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/2
/1
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/2
A R
E
S P
A C
E
S P
A C
E
S P
A R
E
S P
A R
E
S P
A C
E
S P
A C
E
S P
A R
E
S P
A R
E
S P
A C
E
S P
A C
E
S P
A R
E
S P
A R
E
S P
A C
E
S P
A C
E
S P
A R
E
S P
A R
E
S P
A R
E
S P
A C
E
S P
A C
E
S P
A R
E
S P
A C
E
S P
A C
E
S P
A R
E
S P
A R
E
S P
A C
E
S P
A R
E
S P
A C
E
S P
A R
E
S P
A C
E
S P
A C
E
S P
A R
E
S P
A R
E
S P
A R
E
S P
A C
E
S P
A C
E
S P
A C
E
S P
A R
E
S P
A R
E
S P
A C
E
LEVEL 3
LEVEL 4
LEVEL2
LEVEL1
NPL4L1-1, 125A
SHUNT TRIP
208Y/120V 3P,4W
NPL4L1-2, 125A
SHUNT TRIP
208Y/120V 3P,4W
NPL4L1-3, 125A
SHUNT TRIP
208Y/120V 3P,4W
NPL4L1-4, 125A
SHUNT TRIP
208Y/120V 3P,4W
NPL4E2
225A MLO
208Y/120V 3P,4W
NPL4ET1
100A SHUNT TRIP
208Y/120V 3P,4W
NPL4E1
225A MLO
208Y/120V 3P,4W
600A 3P
125A 3P
125A 3P
125A 3P
125A 3P
125A 3P
125A 3P
225A 3P
225A 3P
100A 3P
NPL3E2
225A MLO
208Y/120V 3P,4W
NPL3ET1
100A SHUNT TRIP
208Y/120V 3P,4W
NPL3E1
225A MLO
208Y/120V 3P,4W
NPL3E3
225A MLO
208Y/120V 3P,4W
NPL2ET1
100A SHUNT TRIP
208Y/120V 3P,4W
NPL2E1
225A MLO
208Y/120V 3P,4W
600A 3P
225A 3P
125A 3P
225A 3P
225A 3P
225A 3P
100A 3P
125A 3P
NPL2L1
125A
SHUNT TRIP
208Y/120V 3P,4W
NPL2E2
225A MLO
208Y/120V 3P,4W
NPL2E3
225A MLO
208Y/120V 3P,4W
NTR2E1
T150K
480V-120/208V 3P,4W
NDL2E1
POWER DISTRIBUTION BOARD
600A, 120/208V, 3PH, 4W, 10kAIC
NDL3E1
POWER DISTRIBUTION BOARD
600A, 120/208V, 3PH, 4W, 10kAIC
NDL4E1
POWER DISTRIBUTION BOARD
600A, 120/208V, 3PH, 4W, 10kAIC
NDH1M1
POWER DISTRIBUTION BOARD
800A, 277/480V, 3PH, 4W, 100kAIC c
80Y
SEE E-601 FOR CONTINUATION
NPL1WT1
100A SHUNT TRIP
208Y/120V 3P,4W
NPL1W1
225A MLO
208Y/120V 3P,4W
600A 3P
225A 3P
100A 3P
225A 3P
225A 3P
225A 3P
100A 3P
NPL1W2
225A MLO
208Y/120V 3P,4W
NPL1W3
225A MLO
208Y/120V 3P,4W
NDL1W1
PO…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .