This briefing document and related federal contract opportunity outline plans for a cybersecurity training facility at Fort Gordon, Georgia. The U.S. Army Corps of Engineers Savannah District will issue solicitation W912HN19R3004 on March 19, 2019 for construction of a Sensitive Compartmented Information Facility training, research, and network center. The low-price technically acceptable proposal will be selected for the fixed-price contract, with a 780-day period of performance and magnitude between $25-100 million. Offerors must register in the System for Award Management and proposals are due April 19, 2019, with award by June 2019. The project scope includes instructional spaces, research labs, and network infrastructure to support training at the top secret level.
View the file
Other files
Show all 40
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
US Army Corps of Engineers
BUILDING STRONG®
Savannah District
Industry Day
31 January 2019
US Army Corps of Engineers Cyber Center of Excellence (CCoE) Campus MILCON Program Fort Gordon, GA
AGENDA
1300 Introduction Opening Remarks – COL Daniel Ruder Program Overview Programmatic Schedule Project Specific Information Q & A Session
1400 Closing Remarks
PROGRAM OVERVIEW
Existing CCoE Campus
CCoE Campus End State
BUILDING STRONG®6
Approved by CG 19 Dec 2017 MCA footprints shown are notional and not reflective of a final building shape
Approved CCoE Campus Layout
BUILDING STRONG®7
Current as of 19 December 2018 MCA footprints shown are notional and not reflective of a final building shape
Rendering of CCoE Campus Design
MCA 3
MCA 4
Moran Hall-North (under construction)
MCA 1
MCA 2
DFAC
(existing)
Moran Hall-South Renovation
PROGRAMMATIC SCHEDULE
FISCAL YEAR PROJECT DESCRIPTION Acquisition Strategy Scheduled
Solicitation Date
Scheduled Contract
Award Date
2019 PN 86411
Moran Hall-South (Bldg. 29802)
LPTA Feb 2019 April 2019
2019 PN 88724 – MCA 1 LPTA Mar 2019 Jun 2019
2020 PN 88725 – MCA 2 TBD
Under Design
Feb 2020 Jun 2020
2022 PN 88726 – MCA 3 TBD
Design Pending
Feb 2022 Jun 2022
*2025 PN 88727 – MCA 4 TBD
Design Pending
Feb 2025 *Feb 2021
Jun 2025 *Jun 2021
* There is a possibility that MCA4 may be moved forward and placed in the FY21 MILCON Program.
Project Specific Information
PN 86411 Renovation of Moran Hall South (Bldg. 29802)
Description/Scope: Convert 49,722 GSF of an existing building to provide an Automation-Aided Instructional facility containing a Sensitive Compartmented Information Facility (SCIF) and classroom spaces. Primary facilities include the instructional building, mechanical room, electrical room, telecommunications room, elevator, redundant electrical service, antiterrorism/force protection measures, and building information systems.
Heating and air conditioning will be provided with a connection to the existing central energy plant.
Access for individuals with disabilities will be provided. Sustainability/Energy measures will be provided.
Designer Mason & Hanger
Rendering of Moran Hall South Exterior
PN 88724 SCI Training, Research, and Network Center (MCA1)
Designer HDR, Inc.
Description/Scope: Construct a 139,392 GSF Cyber Instructional Facility & Network Center and includes a standard design Top Secret/Sensitive Compartmented Information (TS/SCI) level Automation-Aided Instructional area consisting of classrooms, instructional labs, instructor offices, conference/counseling rooms, administrative spaces, separate student and staff break areas, student records storage, Research Center, central storage, computer maintenance area, and Network Ops/Digital Training Repository. Non-standard spaces include a secure video teleconferencing center and secure kiosk area.
Supporting facilities include site development, utilities and connections, lighting, paving, parking, walks, curbs and gutters, storm drainage, secure information systems, landscaping and signage. Heating and air conditioning will be provided by connection to the existing energy plant.
PN 88724 SCI Training, Research, and Network Center (MCA1) Acquisition Strategy
Lowest Price Technically Acceptable (LPTA) Award of the project is made to the lowest priced offeror meeting the technical standards of the solicitation.
Offerors will be evaluated on the following:
Submit three recent and relevant projects. Relevant projects are defined as: new vertical construction of any of the following facilities: administrative/office buildings, training/classroom buildings, headquarters/operational facilities, hospitals, or schools, and a minimum contract value of $60M and either completed or 50% constructed within the last 6 years.
One project must contain sensitive compartmentalized information facility (SCIF).
One project that was built on a Department of Defense property/installation or other Federal
Government location that required all of the following: controlled access to the property or the installation; background checks or clearances by the Government of the contractor and subcontractor personnel; and controlled access to a secured construction site.
Factor 2 – Past performance The Offeror shall demonstrate a record of satisfactory or above performance on each project submitted for Factor 1 (Corporate Experience) through information provided through a Past Performance Questionnaire Summary Sheet and a Past Performance Questionnaire (PPQ).
BUILDING STRONG®13
Rendering of MCA1
BUILDING STRONG®14
PN 88725 SCI Mission Command, University Registrar, Force Mod & Proponentcy Facility (MCA2)
Description/Scope: Construct a 235,367 GSF Cyber Instructional Facility which includes a standard design secret level automation-aided instructional area, consisting of classrooms, instructional labs, instructor offices, conference/counseling rooms, administrative spaces, separate student and staff break areas, student records storage, Research Center, central storage, computer maintenance area, a standard design top secret level command and control Facility, secure building information systems, fire detection, protection and alarm systems.
Supporting facilities include site development, utilities and connections, lighting, paving, parking, walks, curbs and gutters, storm drainage, secure information systems, landscaping and signage. Heating and air conditioning will be provided by connection to the
Designer HDR, Inc.
BUILDING STRONG®16
Rendering of MCA2
PN 88726 Secret Cyber & DoD Information Network Training Facility
(MCA3)
Description/Scope: Construct a 221,090 GSF Secret CYBER and Communications Network Training Facility which includes a standard design secret level Automation-Aided Instructional area consisting of classrooms, instructional labs, instructor offices, conference/counseling rooms, administrative spaces, separate student and staff break areas, student records storage, central storage, and computer maintenance area and secret level General Purpose Administrative space. Provide loading/service areas, secure information systems, and fire detection, protection and alarm systems.
Supporting facilities include site development, utilities and connections, lighting, paving, walks, curbs and gutters, storm drainage, secure information systems, landscaping and signage. Heating and air conditioning will be provided by connection to the
Designer TBD
PN 88727 Secret Auditorium & Faculty Ops Facility (MCA4)
Description/Scope: Construct a 82,210 GSF Automation-Aided Instruction Building and general purpose 2,000 person auditorium. The project also includes multi-purpose classrooms, computer maintenance area, information systems, fire protection and alarm systems, Energy Monitoring Control Systems (EMCS) connection, Intrusion Detection System (IDS), Access Control and Closed Circuit TV (CCTV). Sustainability and energy enhancement measures are included.
Supporting facilities include site improvements, hot and chilled water distribution lines, utilities and connections, lighting, paving, walks, storm drainage, and landscaping including developing the campus quadrangle. Heating and air conditioning will be provided by connection to the existing energy plant.
Designer TBD
BUILDING STRONG®19
Fort Gordon Specific Information
Installation Access: Common Access Card (CAC) or approved identification (AIE) Pass/Card will be required for access to Fort Gordon. The Fort Gordon Director of Emergency Services (DES) in coordination w/the COR will require personnel accessing the installation to be vetted and pass an NCIC background check, as addressed in Homeland Security Presidential Directive 12 (HSPD-12). Once NCIC vetting has been completed and approved, the contractor will be issued a paper (short term pass) or AIE Card (long term pass) (type of pass is dependent on the sponsoring unit).
Identification Badges: Common Access Card or Installation passes will be issued through Automated Installation (AIE) Security System. All contractors will undergo a verification process by the Fort Gordon Director of Emergency Services and will be accomplished via National Crime Information Center (NCIC) Interstate Identification Index (III).
Construction Access: Primary construction access will be through Gate # 3 until Summer 2021 and Gate #6 (New Access Control Point) after Summer 2021.
Staging & Laydown Areas: Will be specified in the solicitation.
Savannah District-Points of Contact
Contracting Division:
► Mr. Andrew Page, Andrew.K.Page@usace.army.mil
Project Management:
► Mr. Jose Diaz, jose.d.diaz@usace.army.mil mailto:Andrew.K.Page@usace.army.mil mailto:jose.d.diaz@usace.army.mil
QUESTIONS?
| US Army Corps of Engineers |
| Slide Number 2 |
| Slide Number 3 |
| Existing CCoE Campus |
| CCoE Campus End State |
| Slide Number 6 |
| Slide Number 7 |
| Slide Number 8 |
| Slide Number 9 |
| PN 86411 Renovation of Moran Hall South (Bldg. 29802) |
| Slide Number 11 |
| PN 88724 SCI Training, Research, and Network Center (MCA1)�Acquisition Strategy� |
| Slide Number 13 |
| Slide Number 14 |
| Slide Number 15 |
| Slide Number 16 |
| Slide Number 17 |
| Slide Number 18 |
| Slide Number 19 |
| Fort Gordon Specific Information |
| Savannah District-Points of Contact |
| Slide Number 22 |
File details come from the government source that posted it. Updated .