VA ICU 4 EAST FINAL SUB COMBINED DWGS_VOL.I.pdf
PDF 9 MB Posted
- Solicitation number
- W912HN-10-R-0046
About this file
Dawings Vol I
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WOODLANDS
T-28
BUILDING 100
I-77
CONTRACTORS ENTRY
NOT TO SCALE
106. PSYCHIATRY
104. MEDICAL SCHOOL LECTURE HALL
103. NURSING HOME CARE UNIT
101. MEDICAL SCHOOL LIBRARY
100. 400 BED HOSPITAL, MEDICAL & SURGICAL
T-28. MEDICAL SCHOOL STAFF & RESEARCH
22. ADMINISTRATION BUILDING
20. ENGINEERING OFFICES & SHOPS
10. ADMINISTRATION
9. RESEARCH VA
8. BOILER PLANT
7. WAREHOUSE
6. RESEARCH VA
5. AUDITORIUM/ MAIL ROOM
4. USC MEDICAL SCHOOL RESEARCH
3. PSYCHIATRIC BUILDING
2. MEDICAL SCHOOL
1. BASIC SCIENCE BUILDING
BUILDING
VA
5 21
2087106
ROAD
BYRON
BACK GATE
PARKING
PARKING
GATE
SIDE
ROAD
OLD
STATION
B.P.
COLUMBIA
TO
SHOPPING CENTER
CEDAR TERRACE
SHOPPING CENTER
LANDMARK SQUARE
PARKING
USC-MS
U.S. HIGHWAY 76 & 378
ROAD
LEESBURG
SUMTER
TO
AND OUT OF ECC EACH DAY.
100. CONTRACTOR MUST CHECK IN
LOCATED IN BASEMENT OF BUILDING
ENGINEERING CONTROL CENTER (ECC)
AREA OF WORK - 4th FLOOR EAST
NORTH
CONTRACTOR STORAGE &
PARKING
TO I-26
I-77
TO 1-20
TO
1-26
GARDEN SPRINGS
YORKSHIRE
G
AR
NERS
"VETERANS MEMORIAL FREEWAY"
BLVD
FORT
BLVD
JACKSON
FER
R
Y R D
VILLAGE POND
BURNSIDE
WOODS
HERITAGE
SHOP RD
BRANDON ACRES
KNOLLWOOD
FIELD
MEADOW
TRACE
HAMPTON
LINE
76oSITE
I-7
NORTH
1 2 43 5 6 7 8 9
D
EP
AR
TM
EN
T
O F
VE
TE
R
AN
S
AF
FA
IR
SDATE
PROJECT NO.
DRAWING NO.
FILE NAME
A:Projects/2006- 1111.06
PROJECT TITLE
BUILDING NUMBER CHECKED DRAWN
WILLIAM JENNINGS BRYAN DORN
V A MEDICAL CENTER
COLUMBIA, SOUTH CAROLINA
DRAWING TITLE
APPROVED : CHIEF, LOGISTICS
APPROVED : MED CTR SAFETY MANAGER
APPROVED : INFECTION CONTROL
APPROVED : CHIEF OF STAFF
APPROVED : ASSOC DIR FOR PATIENT/
NURSING SERVICES
APPROVED : DIR., INFRASTRUCTURE
APPROVED : ASSOCIATE DIRECTOR
1 2 43 5 6 7 8 9
A
B
C
D
E
F
DATEREVISIONS
APPROVED : MEDICAL CENTER DIRECTOR
FINAL CONTRACT DOCUMENTS
FULLY SPRINKLERED
APPROVED : STATION ENERGY MANAGER
05.21.10
544-322
GI001
RELOCATE ICU TO 4 EAST
TNS/PAF PRM
COVER SHEET
CAMPUS MAP OWNER
ARCHITECT
RELOCATE ICU TO 4 EAST (BLDG. 100)
DEPARTMENT OF VETERANS AFFAIRS
PROJECT LOCATION: WILLIAM JENNINGS BRYAN DORN MEDICAL CENTER, COLUMBIA, SOUTH CAROLINA
AS001
AD101
AD102
AS101
AS102
AS103
AS104
AS110
AS111
AS112
AS113
AS114
AS115
AS201
AS202
AS203
AS204
AS205
AS301
AS302
AS501
AS502
AS503
AS601
AS701
AS702
AS703
AS704
ARCHITECTURAL
NUMBER
ABBREVIATIONS & SYMBOLS
DEMOLITION FLOOR PLAN
DEMOLITION REF. CEILING PLAN
REFERENCE FLOOR PLAN
DIMENSION FLOOR PLAN
REFLECTED CEILING PLAN
ENLARGED REF. CLG. PLANS
ENLARGED FLOOR PLANS
ENLARGED FLOOR PLANS
ENLARGED FLOOR PLANS
ENLARGED FLOOR PLANS
ENLARGED FLOOR PLANS
ENLARGED FLOOR PLANS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
WALL SECTIONS
SEISMIC REQ'S & CLG. DETAILS
CASEWORK SECTIONS
CASEWORK SECTIONS
SECTIONS & DETAILS
DOOR AND WINDOW SCHEDULE
FINISH PLAN
INTERIOR DETAILS
SIGNAGE
SIGNAGE
TITLE
INDEX OF DRAWINGS
COVER SHEETGI001
LOCATION MAP
STRUCTURAL
GI002 LIFE SAFETY PLAN
FA001
FA101D
FA101
FX001
FX101D
FX101
FIRE PROTECTION
FIRE ALARM LEGEND AND NOTES
FIRE ALARM LEVEL 4 EAST DEMOLITION PLAN
FIRE ALARM LEVEL 4 EAST PLAN
FIRE PROTECTION LEGEND AND NOTES
FIRE PROTECTION LEVEL 4 EAST DEMOLITION
PLAN
FIRE PROTECTION LEVEL 4 EAST PLAN
M001 M101D M101 M102 M104 M201 M301 M302 M501 M601 M701 M702 M703
MECHANICAL
HVAC LEGEND AND GENERAL NOTES
HVAC LEVEL 4 EAST DEMO PLAN
HVAC LEVEL 4 EAST PLAN
PRESSURIZATION PLAN LEVEL 4 EAST
HVAC ROOF EAST PLAN
HVAC LEVEL 4 EAST PIPING PLAN
HVAC LEVEL 4 EAST MECH ROOM PART PLANS
HVAC LEVEL 5 EAST MECH ROOM PART PLANS
HVAC SCHEDULES
HVAC DETAILS
HVAC CONTROLS LEGEND AND NOTES
HVAC CONTROLS - AIR HANDLING UNIT AC-6
HVAC CONTROLS - AIR HANDLING UNIT AC-7
PL001
PL002
PL101
PL102
PL103
PL104
PL111
PL112
PL121
PL122
PL501
PL502
PL503
PL601
PLUMBING
PLUMBING LEGEND AND NOTES
PLUMBING SCHEDULES
PLUMBING LEVEL 3 EAST DEMO PLAN
PLUMBING LEVEL 4 EAST DEMO PLAN
PLUMBING LEVEL 3 EAST SW&V PLAN
PLUMBING LEVEL 4 EAST SW&V PLAN
PLUMBING LEVEL 4 EAST DEMO PLAN
PLUMBING LEVEL 4 EAST WATER PLAN
PLUMBING LEVEL 4 EAST DEMO PLAN
PLUMBING LEVEL 4 EAST MED GAS PLAN
PLUMBING RISER DIAGRAMS
PLUMBING RISER DIAGRAMS
PLUMBING RISER DIAGRAMS
PLUMBING DETAILS
ES001
ES101D
ES101
ES201
ES304D
ES304
ES402
ES501
ES502
ES503
ES504
ES601
ES602
ES603
ELECTRICAL
ELECTRICAL LEGEND AND NOTES
ELECTRICAL LEVEL 4 EAST DEMO PLAN
LIGHTING LEVEL 4 EAST PLAN
POWER LEVEL 4 EAST PLAN
SIGNAL LEVEL 4 EAST DEMOLITION
SIGNAL LEVEL 4 EAST PLAN
SIGNAL RISER DIAGRAM
TELECOMMUNICATIONS DETAILS
TELECOMMUNICATIONS DETAILS
ENLARGED PLANS & DETAILS
SECURITY DEVICE DETAILS
ELECTRICAL SCHEDULES
ELECTRICAL SCHEDULES
ELECTRICAL SCHEDULES
BID ALTERNATES
DEPARTMENT OF VETERANS AFFAIRS
WILLIAM JENNINGS BRYAN DORN MEDICAL
CENTER
NOVUS ARCHITECTS, INC.
PO BOX 1005
MT. PLEASANT, SC 29465-1005
843-849-7407 (FAX) 843-849-6750
BRITT, PETERS & ASSOC.
1100 QUEENSBOROUGH BLVD., SUITE 202
MT. PLEASANT, SC 29464
843-284-0400 (FAX) 843-284-0401
LIFE SAFETY/FIRE PROTECTION CONSULTING
O'BRIEN & GERE
2170 ASHLEY PHOSPHATE RD., SUITE 504
CHARLESTON, SC 29406
843-553-6670 (FAX) 843-553-0755
NEWCOMB & BOYD CONSULTING ENGINEERING GROUP
303 PEACHTREE CENTER AVE., NE, SUITE 525
ATLANTA, GA 30303-1277
404-730-8432 (FAX) 404-730-8401
MECHANICAL / ELEC. / PLUMBING
STRUCTURAL
STRUCTURAL DETAILSS1
007200 General Conditions
1.67 Subcontracts and Work Coordination (VAAR 852.236-80) (April 1984)
The contractor shall be responsible to the government for acts and omissions of his/her own employees, and subcontractors and their employees. The contractor shall also be responsible for coordination of the work of the trades, subcontractors, and material suppliers. The contractor shall, in advance of the work, prepare coordination drawings showing the location of openings through slabs, the pipe sleeves and hanger inserts, as well as the location and elevation of the utility lines, including, but not limited to, converyor systems, pneumatic tubes, ducts, and conduits and pipes 50mm (2 inches) and larger in diameter. These drawings, including plans, elevations, and sections as appropriate shall clearly show the manner in which the utilities fit into the available space and how they relate to each other and to existing building elements. Drawings shall be of appropriate scale to satisfy the previously stated purposes, but not smaller than 9 mm (3/8 inch) scale.
Drawings may be composite (with distinctive colors for the various trades) or may be separate but fully coordinated drawings (such as sepias or photographic paper) reproducible of the same scale. Separate drawings shall depict identical building areas or sections and shall be capable of being overlaid in any combination. The submitted drawings for a given area of the project shall show the work of all trades which will be involved in that particular area. Six complete composite drawings or six complete sets of separate reproducible drawings shall be received by the government not less than 20 days prior to the scheduled start of work in the area illustrated by the drawings for the purpose of showing the contractor's planned method of installation. The objectives of such drawings are to promote carefully planned work sequence and proper trade coordination, in order to assure the expeditious solutions of problems and the installation of lines and equipment as contemplated by the contract documents while avoiding or minimizing additional costs to the contractor and to the government. In the event the contractor, in coordinating the various installations and in planning the method of installation, finds a conflict in the location or elevation of any of the utilities with themselves, with structural items or with other construction items, the contractor shall bring this conflict to the attention of the contracting officer immediately. In doing so, the contractor shall explain the proposed method of solving the problem or shall request instructions as to how to proceed if adjustments beyond those of usual trades coordination are necessary. Utilities installation work will not proceed in any area prior to the submission and completion of the government review of the coordinated drawings for that area, not in any area in which conflicts are disclosed by the coordination drawings until the conflicts have been corrected to the satisfaction of the contracting officer. It is the responsibility of the contractor to submit the required drawings in a timely manner consistent with the requirements to complete the work covered by the contract within the prescribed contract time.
DRAWING COORDINATION
BID ITEM 1, BASE BID: Contractor shall provide all tools, labor, materials, permits, licenses, and supervision for demolition, renovation, and new construction as indicated on drawings and specifications for project 544-322 located at the VA Medical Center in Columbia, SC. Note that drawings and specifications may reflect alternate bid items below. Where drawings and specifications reflect items included in bid alternate scope, omit those items for base bid. Work includes but is not limited to extensive interior demolition; general interior construction; alterations; mechanical and electrical work; utility systems; new finishes. Finishes include carpet; sheet vinyl flooring; solid surface walls and countertops; casework; wood doors and hardware; paint; multi color coatings; and gypsum and acoustical ceilings. General interior construction includes wall systems, interior storefront window systems, hollow metal door frames, and certain other items.
Note: All alternates below are in addition to the base bid and are to be priced separately. Alternates shall be selected by Owner in random order and in any combination required to provide best value within budget limitations.
BID ITEM 2, ALTERNATE 1: Perform all work as described in Bid Item 1. Provide complete LCD glazing system for sliding glass ICU doors as indicated in drawings in spaces 4C100A, 4C101, 4C102, 4C103, 4C104A, 4C105, 4C106, 4C107A, 4C108A, 4C109, 4C110, 4C112, 4C113, 4C114, 4C115, 4C116, 4C117A, 4C118, 4C119, 4C120, and 4C122A. Standard sliding glass ICU corridor doors in spaces 4C100, 4C104, 4C107, 4C108, 4C117, and 4C122A are not to receive LCD glazing. All sliding glass ICU doors are sole source items. See drawings. See electrical. See spec section 08 42 43 for vendor contact info. Note that sliding glass ICU doors in space 4C141 are to receive LCD glazing system as part of base bid.
BID ITEM 3, ALTERNATE 2: Perform all work as described in Bid Item 1. At windows indicated as type ‘A’ (see AS101 & AS601), provide aluminum windows with complete LCD glazing system in lieu of standard interior aluminum storefront windows. LCD-glazed windows are sole source items and are to be provided by the same manufacturer as sliding glass ICU doors. See drawings. See electrical. See spec section 08 42 43 for vendor contact info.
BID ITEM 4, ALTERNATE 3: Perform all work as described in Bid Item 1. At corridor patient observation desks described typically in drawings A6/AS110 and A4/AS111 (11 total), provide counter/floor mounted swinging chairs as indicated in drawings. Swinging chairs are sole source items. See drawings. See equipment schedule for vendor contact info.
BID ITEM 5, ALTERNATE 4: Perform all work as described in Bid Item 1. Provide complete video surveillance system as indicated in drawings. See electrical.
BID ITEM 6, ALTERNATE 5: Perform all work as described in Bid Item 1. Provide vinyl sheet flooring pattern as indicated on sheet AS701. See AS701 and finish schedule (section 09 06 00) for base bid description.
BID ITEM 7, ALTERNATE 6: Perform all work as described in Bid Item 1. At windows indicated as type ‘B’ (see AS101 & AS601), provide aluminum windows with complete LCD glazing system in lieu of standard interior aluminum storefront windows. LCD-glazed windows are sole source items and are to be provided by the same manufacturer as sliding glass ICU doors. See drawings. See electrical. See spec section 08 42 43 for vendor contact info.
BID SET
UP
NURSE MGR
4C163
STRETCHER / EQUIP.
STORAGE
4C111
CCU/MICU BED
4C109
PCU BED
4C103
PCU BED
4C101
CONF./STOR. ROOM
4C140
PCU/ISO BED
4C122A
PCU BED
4C120PCU BED
4C118
CCU/MICU ISO BED
4C117A
CCU/MICU BED
4C116
CCU/MICU BED
4C115
CCU/MICU BED
4C114
CCU/MICU BED
4C113
CCU/MICU BED
4C112
ON CALL
4C161
CLEAN UTILITY
4C164
LINEN
4C165 STAFF TOILET
4C156
SOILED UTILITY
4C160
BREAK ROOM
4C152
T.S.C.
4C121
NOURISHMENT
4C147
H.A.C.
4C148
MED GAS
4C159
CLEAN UTILITY
4C151
LINEN
4C144
STAFF TOILET
4C143
NURSE SUPER/CLIN.
PHARM
4C153
SOILED UTILITY
4C150
CORRIDOR
4C170
CORRIDOR
4C166
STAIR
PYXIS
PYXIS
FEC
MAXIMUM OVERALL DIAGONAL DIMENSION - 195'
DISTANCE BETWEEN EXISTING EXITS - 187' 8"
EXIT TRAVEL DISTANCE - 128' - 8"
EXIT TRAVEL DISTANCE - 129' -4"
EXIT TRAVEL DISTANCE - 97' - 10" EXIT TRAVEL DISTANCE - 143' - 4"
PT
STATION
CCU/MICU ISO BED
4C108A
CCU/MICU BED
4C106
ANTEROOM
4C107
BATH
4C103A
PCU BED
4C102
BATH
4C102A
BATH
4C101A
PCU/ISO BED
4C100A
BATH
4C118A
BATH
4C119A
BATH
4C120A
PCU BED
4C119
BATH
4C122B
XFEC
ANTEROOM
4C108
CCU/MICU ISO BED
4C107A
CCU/MICU BED
4C105
CCU/MICU ISO BED
4C104A
ANTE ROOM
4C104
CONFERENCE
4C145
MEDS RM
4C142
PROCEDURE ROOM
4C141
CONF. ROOM
4C139
ANTE ROOM
4C122
ANTE ROOM
4C100
STORAGE
4C157
MED RM
4C158
NURSE'S STATION
4C149
NURSE'S STATION
4C149
HVAC
4C131
FEC
FEC
FEC1'
/2
FIRE EXTINGUSHER CABINETFEC
FIRE EXIT SIGN
EXISTING FIRE EXTINGUSHER CABINETXFEC
1. REFER TO FIRE PROTECTION PLANS FOR ALL SPRINKLER AND ALARM COMPONENT
LOCATIONS NOT PROVIDED ON THIS SHEET.
2. FIRE EXTINGUISHERS PLACED PER NFPA 10 - MAXIMUM TRAVEL DISTANCE 75'-0"
3. SEE MECHANICAL FOR FIRE AND SMOKE DAMPER REQUIREMENTS
4.EXISTING STEEL COLUMNS PROTECTED W/ GYPSUM BLOCK/BOARD FIREPROOFING,
AND STEEL BEAMS & DECK PROTECTED W/ SPRAY APPLIED FIREPROOFING UNLESS
NOTED OTHERWISE. (GC RESPONSIBLE FOR MAINTAINING INTEGRITY OF ALL EXISTING
RATED ELEMENTS UNLESS OTHERWISE CALLED FOR IN THE CONTRACT DOCUMENTS,
AND COORDINATING APPROPRIATE INSPECTIONS BY VA SAFETY PERSONNEL W/
PROJECT ENGINEER)
5. GYPSUM BLOCK/BOARD & SPRAY APPLIED FIREPROOFING TO REMAIN IN PLACE AND
BE REPAIRED AS REQUIRED. FIRESTOP ALL NEW PENETRATIONS THROUGH EXISTING
FIRE RATED AND SMOKE RATED WALLS AND PARTITIONS TO MAINTAIN EXISTING FIRE
AND/OR SMOKE RATING OF EXISTING WALLS AND PARTITIONS. EXISTING FIRE RATED
AND SMOKE BARRIER WALLS REMAINING SHALL BE REPAIRED TO MAINTAIN REQUIRED
RATING.
SMOKE PARTITION (SEE FLOOR PLANS
FOR WALL AND DOOR DESIGNATIONS)
1 HR. FIRE AND SMOKE BARRIER PER UL #419
(SEE FLOOR PLANS FOR WALL AND DOOR
DESIGNATIONS)
1 HR. FIRE BARRIER PER UL #419 (SEE FLOOR
PLANS FOR WALL AND DOOR DESIGNATIONS)
EXISTING 1 HR. FIRE AND SMOKE BARRIER
EXISTING 2 HR. FIRE AND SMOKE BARRIER
APPLICABLE CODES (IN ORDER OF AUTHORITY)
1. VA FIRE PROTECTION DESIGN MANUAL
2. NFC CODES 2009
3. INTERNATIONAL CODES 2006
OCCUPANCY CLASSIFICATION
HEALTHCARE (NFPA 101, 6.1.5)
OCCUPANT LOAD
A. SLEEPING DEPARTMENTS: 13,983 SQ. FT./120=116 OCCUPANTS
B. EXISTING MECHANICAL ROOM: 1,460 SQ. FT./500=3 OCCUPANTS
C. 119 OCCUPANTS TOTAL
CONSTRUCTION CLASSIFICATION
TYPE I (332) - (NFPA 220)
FULLY SPRINKLERED
FIRE RESISTANCE REQUIREMENTS BY BUILDING COMPONENT
STRUCTURAL FRAME - 3 HOUR PROTECTED
BEARING WALLS - (INTERIOR & EXTERIOR) -1 HOUR PROTECTED
NONBEARING WALLS AND PARTITIONS - 0 HOUR
FLOOR CONSTRUCTION - 2 HOUR PROTECTED
(*VERIFY EXISTING CONSTRUCTION MEETS THESE REQUIREMENTS)
HAZARDOUS AREA SEPERATION - SMOKE PARTITION CONSTRUCTION (NFPA 101,
8.7.1.2)
MED GAS
SOILED LINEN
STORAGE > 100 SQ. FT.
EXIT LOCATION REQUIREMENTS
MAX. TRAVEL DISTANCE TO EXIT - 200 FT. (NFPA 101, 18.2.6)
MAX. COMMON PATH OF TRAVEL - 100 FT. (NFPA 101, 18.2.5.3)
DEAD END CORRIDOR - 30 FT. (NFPA 101, 18.2.5.2)
2 EXITS REQUIRED - REMOTELY LOCATED PER NFPA 101, 18.2.4.3
2 ACCESSIBLE MEANS OF EGRESS REQUIRED (NFPA 101, 7.5.4.1)
PROVIDED - 1 AREA OF REFUGE, AND 1 ACCESSIBLE EXIT (ADDITIONAL AREA OF
REFUGE PROVIDED IN STAIR #5 AS AN ALTERNATE TO RAMP CONSTRUCTION.) PER
NFPA 101, 18.2.2.10, AREAS OF REFUGE SHALL COMPLY W/ 7.2.12
1 2 43 5 6 7 8 9
D
EP
AR
TM
EN
T
O F
VE
TE
R
AN
S
AF
FA
IR
SDATE
PROJECT NO.
DRAWING NO.
FILE NAME
A:Projects/2006- 1111.06
PROJECT TITLE
BUILDING NUMBER CHECKED DRAWN
WILLIAM JENNINGS BRYAN DORN
V A MEDICAL CENTER
COLUMBIA, SOUTH CAROLINA
DRAWING TITLE
APPROVED : CHIEF, LOGISTICS
APPROVED : MED CTR SAFETY MANAGER
APPROVED : INFECTION CONTROL
APPROVED : CHIEF OF STAFF
APPROVED : ASSOC DIR FOR PATIENT/
NURSING SERVICES
APPROVED : DIR., INFRASTRUCTURE
APPROVED : ASSOCIATE DIRECTOR
1 2 43 5 6 7 8 9
A
B
C
D
E
F
DATEREVISIONS
APPROVED : MEDICAL CENTER DIRECTOR
FINAL CONTRACT DOCUMENTS
FULLY SPRINKLERED
APPROVED : STATION ENERGY MANAGER
05.21.10
544-322
GI002
RELOCATE ICU TO 4 EAST
TNS/PAF SNP
LIFE SAFETY PLAN
LIFE SAFETY GENERAL NOTES
CODE ANALYSIS
SCALE: 1/8" = 1'-0"GI002
LIFE SAFETY PLANA2
1. THIS WING, AS DEFINED BY EXTERIOR WALLS AND EXISTING TWO HR.
FIRE/SMOKE BARRIER, COMPRISES A SMOKE COMPARTMENT OF 15,680 SQ. FT.
2.EGRESS CAPACITY: (NFPA 101 TABLE 7.3.3.1)
A.SPRINKLERED OCCUPANCY: 0.2"X120 OCCUPANTS = 24". EXISTING
EXIT DOORS PROVIDE 127" CLEAR WIDTH. PROPOSED EXIT ACCESS
CORRIDOR WIDTH IS 8'.
3.TWO EXISTING EXITS ARE PROVIDED FROM THIS SMOKE COMPARTMENT. TWO
EXITS ARE REQUIRED BY NFPA 101 PARAGRAPH 18.2.4.3.
4. NFPA 101, PARAGRAPH 7.1.3.2.1 REQUIRES ENCLOSURE OF
INTERIOR VERTICAL EXITS BY TWO-HOUR FIRE BARRIERS WHERE SERVING FOUR
OR MORE FLOORS. EXISTING TWO-HOUR FIRE BARRIER AT STAIRWELL IS TO BE
MAINTAINED.
5.CORRIDOR WALLS TO BE CONSTRUCTED AS SMOKE PARTITIONS TO COMPLY
WITH NFPA 101, PARAGRAPH 18.3.6.2. SMOKE PARTITION WILL MEET THE
REQUIREMENTS OF NFPA 101-8.4 WITH THE EXCEPTION OF 8.4.2 (2) AND (3). SMOKE
PARTITIONS WILL TERMINATE AT THE FLOOR DECK ABOVE.
6.TO COMPLY WITH NFPA 101, PARAGRAPH 18.6.3.1, CORRIDOR DOORS IN SMOKE
PARTITIONS WILL PROVIDE EFFECTIVE RESISTANCE TO PASSAGE OF SMOKE AND
WILL BE EQUIPPED WITH POSITIVE LATCHING. CLOSERS ARE NOT REQUIRED FOR
SMOKE PARTITIONS. PROVIDE DOOR CLOSERS FOR ALL DOORS IN FIRE RATED
CONSTRUCTION.
7. NFPA 101 SECTION 18.3.3.2 - INTERIOR WALL AND CEILING FINISHES: EXIT
ENCLOSURES AND CORRIDORS - CLASS A; ROOMS AND ENCLOSED SPACES (LIMIT
4/ROOM) - CLASS A OR B. NFPA 101 SECTION 18.3.3.3 AND 10.2.7.1 & 10.2.7.2 - FLOOR
FINISHES: CLASS I OR II.
8. NEW SPRINKLER SYSTEM TO MEET REQUIREMENTS OF NFPA 13.
9. FLOORS ABOVE & BELOW SERVE AS A TWO-HOUR FIRE BARRIER. ALL
PENETRATIONS ARE TO BE PROTECTED AS REQUIRED TO MAINTAIN RATING. UL
LISTED DETAILS ARE REQUIRED FOR ALL PENETRATIONS. SEE MPE.
LIFE SAFETY WALL DESIGNATIONS
LIFE SAFETY LEGEND
PLAN NORTH
TRUE NORTH
CODE NOTES
AF.F. ABOVE FINISH FLOOR
ALUM. ALUMUNIMUM
ANOD. ANODIZED
ARCH. ARCHITECTURAL/ARCHITECT
@ AT
BRG. BEARING
BOT. BOTTOM
BLDG. BUILDING
(C) CAULK
CAB. CABINET
C.F.C.I. CONTRACTOR FURNISHED, CONTRACTOR INSTALLED
C.F.O.I. CONTRACTOR FURNISHED, OWNER INSTALLED
CLG. CEILING
CPT. CARPET
CTR. CENTER
CLOS. CLOSET
COL. COLUMN
CONC. CONCRETE
C.J. CONTROL JOINT
DTL. DETAIL
DIA. DIAMETER
DIM. DIMENSION
DN. DOWN
DWG. DRAWING
EA. EACH
ELEC. ELECTRIC/ELECTRICAL
E.W.C. ELECTRIC WATER COOLER
ELEV. ELEVATION-GRADEORBLDG.
E.J. EXPANSION JOINT
EQ. EQUAL
EQUIP. EQUIPMENT
E.F. EXHAUST FAN
EXIST.,(E) EXISTING
EXT. EXTERIOR
FT. FEET
FIN. FINISH
F.E. (ON WALL BRACKET) FIRE EXTINGUISHER
F.E.C. (IN WALL CABINET) FIRE EXTINGUISHER
FLR. FLOOR
F.D. FLOOR DRAIN
GALV. GALVANIZED
GA. GAUGE
GYP.BD. GYPSUM BOARD
HC HANDICAP ACCESSIBLE
HDWR. HARDWARE
HT. HEIGHT
H.M. HOLLOW METAL
HORIZ. HORIZONTAL
INSUL. INSULATION
INT. INTERIOR
JAN. JANITOR
JT. JOINT
LAM. LAMINATE
LAV. LAVATORY
MFR. MANUFACTURER
M.O. MASONRY OPENING
MATL. MATERIAL
MAX. MAXIMUM
MECH. MECHANICAL
MTL. METAL MIN. MINIMUM
(N) NEW
N.I.C. NOT IN CONTRACT
N.T.S. NOT TO SCALE
O.C. ON CENTER
O.F.C.I. OWNER FURNISHED, CONTRACTOR INSTALLED
O.F.O.I. OWNER FURNISHED, OWNER INSTALLED
OPNG. OPENING
O.H. OPPOSITE HAND
O.R.D. OVER FLOW ROOF DRAIN
(P) PAINT
PLYWD. PLYWOOD
PR. PAIR
PREF. PRE FINISHED
PREFAB. PREFABRICATED
RADIUS RAD., R.
RE: REFERENCE
REINF. REINFORCE
REQ'D. REQUIRED
(LEADER) R.D. ROOF DRAIN
(L) R.O. ROUGH OPENING
SHT. SHEET
SIM. SIMILAR
SPECS. SPECIFICATIONS
S.S. STAINLESS STEEL
STD. STANDARD
STL. STEEL
STRUCT. STRUCTURAL
TEL. TELEPHONE
TR. TREATED
TYP. TYPICAL
U.N.O. UNLESS NOTED OTHERWISE
(V) VERIFY
V.C.T. VINYL COMPOSITION TILE
VERT. VERTICAL
V.T.R. VENT THROUGH ROOF
W.C. WATER CLOSET
WD. WOOD
1/8" = 1'-0"A102 A401
12"
18"
DETAIL IS REFERENCED
SHEET NO. WHERE
View Name
DETAIL W/ REFERENCE
PLAN OR SECTION
DETAIL NUMBER
DETAIL IS DRAWN
SHEET NO. WHERE
HARDWARE SET
DOOR SIZE
DOOR TYPE
JAMB TYPE
1 5 H T
ROOM NUMBER
ROOM NAME
AROUND AREA DETAILED
MEDIUM DASHED LINE
SHEET NO. WHERE
DETAIL NUMBER
SHEET NO. WHERE
DETAIL NUMBER
SECTION IS DRAWN
DETAIL IS DRAWN
& NUMBER
ROOM NAME
COLUMN GRID LINE
DETAIL
PLAN OR SECTION
SECTION DETAIL
BUILDING OR WALL
SECTION IS DRAWN
SHEET NO. WHERE
ELEVATION IS DRAWN
SHEET NO. WHERE
ELEVATION IS DRAWN
SHEET NO. WHERE
DETAIL NUMBER
DETAIL NUMBER
DOOR MODIFICATION
TO MEET ADA REQUIREMENTS)
WINDOW TYPE IS DRAWN
SEE DOOR SCHEDULE
DETAIL NUMBER
DETAIL
OR WALL
SECTION DETAIL
DETAIL
DOOR NUMBER
WINDOW TYPE
STOREFRONT OR
EXTERIOR ELEVATION
INTERIOR ELEVATION
WALL PARTITION TYPE
TYPE
WALL PARTITION
DETAIL NUMBERPARTIAL BUILDING
(PROVIDE MIN. CLEARANCES SHOWN
A
LOBBY
AS101
A1
AS101
A1
AS101
A1
AS101
A1
AS101
A1
X
1 2 43 5 6 7 8 9
D
EP
AR
TM
EN
T
O F
VE
TE
R
AN
S
AF
FA
IR
SDATE
PROJECT NO.
DRAWING NO.
FILE NAME
A:Projects/2006- 1111.06
PROJECT TITLE
BUILDING NUMBER CHECKED DRAWN
WILLIAM JENNINGS BRYAN DORN
V A MEDICAL CENTER
COLUMBIA, SOUTH CAROLINA
DRAWING TITLE
APPROVED : CHIEF, LOGISTICS
APPROVED : MED CTR SAFETY MANAGER
APPROVED : INFECTION CONTROL
APPROVED : CHIEF OF STAFF
APPROVED : ASSOC DIR FOR PATIENT/
NURSING SERVICES
APPROVED : DIR., INFRASTRUCTURE
APPROVED : ASSOCIATE DIRECTOR
1 2 43 5 6 7 8 9
A
B
C
D
E
F
DATEREVISIONS
APPROVED : MEDICAL CENTER DIRECTOR
FINAL CONTRACT DOCUMENTS
FULLY SPRINKLERED
APPROVED : STATION ENERGY MANAGER
05.21.10
544-322
AS001
RELOCATE ICU TO 4 EAST
TNS/PAF SNP
ABBREVIATIONS & SYMBOLS
SYMBOL LEGEND ABBREVIATIONS
WALL TYPES
TYPE
MARK
FIRE
BARRIER
RATING DESCRIPTION DETAIL
1 EXISTING INTERIOR PARTITION. PATCH
AS REQ'D FOR CONTINUOUS GYP BRD
FINISH AND ALIGN W/ NEW ADJACENT
CONSTRUCTION. NEW & EXISTING GYP
BRD TO BE PAINTED (P-1). SEE FINISH
SCHEDULE
1.1 EXISTING EXTERIOR WALL. PATCH AS
REQ'D. AT REMOVED INTERIOR
PARTITION LOCATIONS FOR
CONTINUOUS GYP BRD FINISH. NEW &
EXISTING GYP BRD TO BE PAINTED
(P-1). SEE FINISH SCHEDULE. SEE
FINISH PLAN FOR NEW RIGID VINYL
SHEET LOCATIONS.
2 1 HR FIRE
/ SMOKE
EXISTING 1-HOUR FIRE/SMOKE
BARRIER. NEW AND EXISTING
PENETRATIONS TO BE PROPERLY
SEALED AND PROTECTED TO
MAINTAIN RATING. PATCH AS REQ'D TO
MAINTAIN RATING AT REMOVED WALL
LOCATIONS. NEW & EXISTING GYP BRD
TO BE PAINTED ON
CORRIDOR/PATIENT ROOM/EQUIP
STORAGE SIDE (P-1). SEE FINISH
SCHEDULE. SEE FINISH PLAN FOR
RIGID VINYL SHEET LOCATIONS.
3 2 HR FIRE
/ SMOKE
EXISTING 2-HOUR FIRE/SMOKE
BARRIER. NEW AND EXISTING
PENETRATIONS TO BE PROPERLY
SEALED AND PROTECTED TO
MAINTAIN RATING.
4 EXISTING WALL TO BE UPGRADED TO
SMOKE PARTITION.
B3/AS301
SIMILAR
5 NEW WALL, 3 5/8" METAL STUDS, 3-1/2"
SOUND ATTENUATION BLANKETS, W/
5/8" GYP BRD EACH SIDE UNLESS
SHOWN OTHERWISE.
6 NEW SMOKE PARTITION W/ 3-1/2"
SOUND ATTENUATION BLANKETS.
PROVIDE 6" METAL STUDS AT
PLUMBING WALLS.
7 1 HR
UL# 419
NEW 1-HOUR FIRE BARRIER W/ 3-1/2"
SOUND ATTENUATION BLANKETS.
PROVIDE 6" METAL STUDS AT
PLUMBING WALLS
7.1 1 HR FIRE
/ SMOKE
UL#419
NEW 1-HOUR FIRE/SMOKE BARRIER W/
3-1/2" SOUND ATTENUATION
BLANKETS. PROVIDE 6" METAL STUDS
AT PLUMBING WALLS
8 NEW CHASE W/ 3-1/2" SOUND
ATTENUATION BLANKETS. CHASE TO
ACCOMODATE CARRIERS AT WALL
MOUNTED LAVS, SINKS, & TOILETS,
ETC. CONSTRUCT AS SMOKE
PARTITION WHERE REQ'D.
9 NEW PLUMBING WALL, W/ 3-1/2" SOUND
ATTENUATION BLANKETS. PROVIDE 6"
METAL STUDS W/ 5/8" GYP BD EACH
SIDE.WALL TO ACCOMODATE
CARRIERS AT WALL MOUNTED LAVS.
9.1 NEW PLUMBING WALL, W/ 3-1/2" SOUND
ATTENUATION BLANKETS. PROVIDE 8"
WIDE METAL STUD FRAMING W/ 5/8"
GYP BD EACH SIDE.WALL TO
ACCOMODATE CARRIERS AT WALL
MOUNTED LAVS.
B5/AS301
SIMILAR
WALL LEGEND
B3/AS301
B1/AS301
B1/AS301
SIMILAR
B7/AS301
B5/AS301
PT
STATION
A
A
B
B
F
F
G
G
H
H
I
I
J
J
K
K
C
C
1 1
2 2
3 3
4 4 8 8 8 8 8 8 8 8 8 8
88888888
5 5 10 10 10 10 10 10 10 10 10 10 10
555555
3 3
33 3 3
3 3
3 3 3
3 3
3 3
3 3
3 3
5 10
10 10 10
10 10 10 10 10 10
10 10
111111
10 10
10 10
10 10
10 10 10
9FEC
FEC
11 11 11
D
D
FEC
15 17
WALL TO REMAIN
WALL TO REMOVE
FEC EXISTING FIRE ALARM CABINET TO
REMAIN UNLESS NOTED OTHERWISE
EXISTING PNEUMATIC TUBE STATION TO BE RELOCATED. PROTECT DURING
CONSTRUCTION. VA TUBE SYSTEM VENDOR IS TO BE ENGAGED FOR REQUIRED
WORK & INCLUDED IN THE GC'S CONSTRUCTION CONTRACT. CONTACT VENDOR
FOR EXACT SCOPE OF WORK (PEVCO SYSTEMS 800-738-2699). SEE ELECTRICAL.
TUBE SYSTEM PIPING TO BE CONFIGURED AS REQUIRED FOR RELOCATION.
SEE MPE FOR DEMOLITION IN EXISTING MECH. ROOM
REMOVE FULL HEIGHT MTL. LOCKERS COMPLETE.
EXISTING BUILDING EXPANSION JOINT. METAL COVER PLATES &
FIRESTOP MATERIAL TO REMAIN. PROTECT DURING CONSTRUCTION.
REMOVE FULL HEIGHT MED GAS / POWER COLUMN AND WALL MOUNTED OVERBED
LIGHT FIXTURES COMPLETE. SEE MPE.
REMOVE ACCORDION PARTITION AND TRACK COMPLETE.
EXISTING STAINLESS STEEL WINDOW SILL TRIM TO BE MODIFIED AS REQUIRED TO
ACCOMODATE REDUCED WALL WIDTH.
REMOVE FLOOR MOUNTED HVAC EQUIPMENT. SEE MPE.
REMOVE FIRE EXTINGUISHER CABINET COMPLETE.
EXCEPT FOR GYP. BOARD FINISH AT WALLS TO REMAIN, ALL FINISHES TO BE
REMOVED. EXISTING FINISHES IN THIS SPACE INCLUDE PAINTED GYP. BOARD,
RUBBER WALL BASE, & VCT FLOOR.
EXCEPT FOR GYP. BOARD FINISH AT WALLS TO REMAIN, ALL FINISHES TO BE
REMOVED. EXISTING FINISHES IN THIS SPACE INCLUDE PAINTED GYP. BOARD, 4x4 CT WAINSCOT, AND 1x1 CT FLOOR.
12 EXCEPT FOR GYP. BOARD FINISH AT WALLS TO REMAIN, ALL CORRIDOR
FINISHES TO BE REMOVED. CORRIDOR FINISHES INCLUDE PAINTED GYP
BOARD, 4x4 CT WAINSCOT, RUBBER WALL BASE.
13 REMOVE WALL MOUNTED FAN UNIT.
14 EXISTING FURRED WALL TO BE REMOVED.
16 EXISTING 20 MIN. DOUBLE EGRESS DOORS TO BE REPLACED W/ 1-
HOUR FIRE DOORS FOR DURATION OF CONSTRUCTION. NEW FIRE
RATED AUTOMATIC DOUBLE EGRESS DOORS TO BE PROVIDED AS
PART OF WORK. SEE AS101.
HOSE REEL IS TO BE PROVIDED BY GC AT OR NEAR THIS
LOCATION WITH ALL REQUIRED CONNECTIONS AND IS TO BE
MAINTAINED THROUGHOUT DEMOLITION PHASE.
PROVIDE TWO 6" DIA. PENETRATIONS THROUGH SLAB FOR RELOCATED
PNEUMATIC TUBE RISERS. COORDINATE EXACT LOCATIONS W/
PNEUMATIC TUBE SYSTEM VENDOR (PEVCO SYSTEMS).
18 FOR DURATION OF COSTRUCTION, SIGN TO BE PROVIDED ON OUTSIDE
OF DOORS INDICATING "NO EXIT". EXISTING EXIT SIGNS &
DIRECTIONAL ARROWS POINTING TO AREA OF WORK ARE TO BE
COVERED.
1 2 43 5 6 7 8 9
D
EP
AR
TM
EN
T
O F
VE
TE
R
AN
S
AF
FA
IR
SDATE
PROJECT NO.
DRAWING NO.
FILE NAME
A:Projects/2006- 1111.06
PROJECT TITLE
BUILDING NUMBER CHECKED DRAWN
WILLIAM JENNINGS BRYAN DORN
V A MEDICAL CENTER
COLUMBIA, SOUTH CAROLINA
DRAWING TITLE
APPROVED : CHIEF, LOGISTICS
APPROVED : MED CTR SAFETY MANAGER
APPROVED : INFECTION CONTROL
APPROVED : CHIEF OF STAFF
APPROVED : ASSOC DIR FOR PATIENT/
NURSING SERVICES
APPROVED : DIR., INFRASTRUCTURE
APPROVED : ASSOCIATE DIRECTOR
1 2 43 5 6 7 8 9
A
B
C
D
E
F
DATEREVISIONS
APPROVED : MEDICAL CENTER DIRECTOR
FINAL CONTRACT DOCUMENTS
FULLY SPRINKLERED
APPROVED : STATION ENERGY MANAGER
05.21.10
544-322
AD101
RELOCATE ICU TO 4 EAST
TNS/PAF SNP
DEMOLITION FLOOR PLAN
SCALE: 1/8" = 1'-0"AD101
FLOOR PLAN - DEMOLITIONA2
LEGEND GENERAL DEMOLITION NOTES
1. THIS PLAN REPRESENTS EXISTING CONDITIONS. IT IS INTENDED FOR REFERENCE
ONLY. THE PLAN IS NOT INTENDED AS A DETAILED DESCRIPTION OF ALL OBJECTS
REQUIRED TO BE REMOVED IN ORDER TO CONSTRUCT THE WORK.
2. DEMOLISH EXISTING WALLS SHOWN DASHED ON THE PLAN. INCLUDE SHORING
AND/OR STRUCTURAL IMPLENTS AS REQUIRED TO PROVIDE A SOUND PERMANENT
STRUCTURE PER APLICABLE CODES.
3. ALL EXISTING PLUMBING FIXTURES TO BE REMOVED COMPLETE. SEE MPE. ALL
VANITY SINKS, COUNTERTOPS / CASEWORK, AND ACCESORIES (INCLUDING BUT NOT
LIMITED TO MIRRORS, PT DISPENSER, SOAP DISPENSERS) TO BE REMOVED COMPLETE.
ALL SHOWERS TO BE REMOVED COMPLETE (INCLUDING BUT NOT LIMITED TO PLUMBING
ACCESSORIES, TILE ENCLOSURES). SHOWER CURBS TO BE REMOVED FLOORS ARE TO
BE REMOVED TO LEVEL OF ADJACENT FLOOR SLAB.
4. REMOVE ALL MECHANICAL, PLUMBING, AND ELECTRICAL NOT NOTED FOR REUSE AND
CAP. SEE MPE DEMOLITION PLANS.
5. ALL COLUMNS, BEAMS, BRACING AND STRUCTURAL ELEMENTS TO REMAIN UNLESS
OTHERWISE NOTED.
6. EXISTING THREE-HOUR STRUCTURAL FIREPROOFING TO REMAIN. REPAIR AS
REQUIRED TO MAINTAIN RATING. EXISTING STEEL COLUMNS ARE PROTECTED W/
GYPSUM BLOCK/BOARD. EXISTING STEEL BEAMS & DECK ARE PROTECTED W/ SPRAY
APPLIED FIREPROOFING.
7. UNLESS OTHERWISE NOTED, GYP. BOARD WALL FINISH, WINDOWS, & WINDOW SILLS
AT EXTERIOR WALLS TO REMAIN.
8. ABATEMENT OF ASBESTOS-CONTAINING TILE AND MASTIC THROUGHOUT THE AREA
TO BE CARRIED OUT BY THE VA. GC TO PERFORM ALL OTHER DEMOLITION AS INDICATED
AND COORDINATE W/ VA PROJECT MANAGER TO ALLOW TIME AND ACCESS FOR
ASBESTOS ABATEMENT.
9. COORDINATE W/ VA PROJECT ENGINEER REGARDING PHASING OF DEMOLITION
AFFECTING OTHER FLOORS / BUILDING AREAS. ADJACENT FLOORS & BUILDING AREAS,
WILL BE OCCUPIED AND ARE TO REMAIN OPERATIONAL DURING CONSTRUCTION.
10. AT COMPLETION OF DEMOLITION, COORDINATE WITH VA PROJECT ENGINEER FOR
INSPECTION AND REVIEW OF EXISTING CONDITIONS (INCLUDING FIRE-RATED
PENETRATIONS) AND MPE ITEMS TO REMAIN.
11. AT WALLS TO REMAIN INCLUDING EXTERIOR WALLS, REMOVE ANY VINYL WALL
COVERING, WALL PAPER TRIM, WALL BASE, CHAIR RAIL MOULDING, ETC. ONLY GYP.
BOARD FINISH TO REMAIN.
12. DUST IS TO BE CONTAINED WITHIN THE WORK AREA. COORDINATE W/ MECHANICAL
PHASING TO KEEP DUST OUT OF DUCTWORK & MINIMIZE THE SPREAD OF
CONSTRUCTION DUST.
13. SEE AD102 FOR CEILING DEMOLITION REQUIREMENTS.
14. PROTECT ANY FINISHES TO REMAIN DURING CONSTRUCTION.
15. EXISTING 2-HOUR FLOOR & CEILING SEPARATIONS TO REMAIN. REPAIR AS REQ'D TO
MAINTAIN RATING LEAVING NO OPEN PENETRATIONS AT CLOSE OF DAILY ACTIVITIES. USE
TEMPORARY SYSTEM (2-HOUR RATED) WHERE PENETRATIONS ARE TO BE ACCESSED
LATER FOR ONGOING WORK.
KEY NOTES
PLAN NORTH
A
B
B
F
F
G
G
H
H
I
I
J
J
K
K
C
C
TV
TV
TVTV
TV
4 4 4
D
D
TV
2x2 LIGHT FIXTURE TO BE REMOVED. SEE MPE.
2x4 LIGHT FIXTURE TO BE REMOVED. SEE MPE.
1x4 LIGHT FIXTURE TO BE REMOVED. SEE MPE.
SUPPLY GRILL TO BE REMOVED. SEE MPE.
RETURN GRILL TO BE REMOVED. SEE MPE.
SPEAKER TO BE REMOVED. SEE MPE.
EXIT SIGN TO BE REMOVED. SEE MPE.
CEILING MOUNTED TV & BRACKET TO BE REMOVED. SEE MPE.
GYP BOARD CEILING & FRAMING ASSOCIATED TO BE REMOVED
CURTAIN TRACK TO BE REMOVED
2x2 ACOUSTICAL CEILING TO BE REMOVED
METAL ACCESS PANEL TO BE REMOVED.
ITEM TO REMAIN
ITEM TO BE REMOVED
1x1 SUPPLY GRILL TO BE REMOVED. SEE MPE.
1x1 RETURN GRILL TO BE REMOVED. SEE MPE.
REMOVE HEAVY DUTY STAINLESS STEEL LIFT RAIL COMPLETE.
NO DEMOLITION THIS AREA.
NO CEILING IN THIS SPACE. SEE MPE FOR DEMOLITION IN THIS AREA.
REMOVE ACCORDION PARTITION, TRACK, AND SOFFIT COMPLETE.
REMOVE CUBICLE CURTAIN & TRACK SYSTEM COMPLETE.5
1 2 43 5 6 7 8 9
D
EP
AR
TM
EN
T
O F
VE
TE
R
AN
S
AF
FA
IR
SDATE
PROJECT NO.
DRAWING NO.
FILE NAME
A:Projects/2006- 1111.06
PROJECT TITLE
BUILDING NUMBER CHECKED DRAWN
WILLIAM JENNINGS BRYAN DORN
V A MEDICAL CENTER
COLUMBIA, SOUTH CAROLINA
DRAWING TITLE
APPROVED : CHIEF, LOGISTICS
APPROVED : MED CTR SAFETY MANAGER
APPROVED : INFECTION CONTROL
APPROVED : CHIEF OF STAFF
APPROVED : ASSOC DIR FOR PATIENT/
NURSING SERVICES
APPROVED : DIR., INFRASTRUCTURE
APPROVED : ASSOCIATE DIRECTOR
1 2 43 5 6 7 8 9
A
B
C
D
E
F
DATEREVISIONS
APPROVED : MEDICAL CENTER DIRECTOR
FINAL CONTRACT DOCUMENTS
FULLY SPRINKLERED
APPROVED : STATION ENERGY MANAGER
05.21.10
544-322
AD102
RELOCATE ICU TO 4 EAST
TNS/PAF SNP
DEMOLITION REF. CEILING PLAN
SCALE: 1/8" = 1'-0"AD102
DEMO REFLECTED CEILING PLANA2
DEMOLITION KEY NOTES
GENERAL DEMOLITION NOTES
LEGEND
1. THIS PLAN REPRESENTS EXISTING CONDITIONS. IT IS INTENDED FOR REFERENCE ONLY.
THE PLAN IS NOT INTENDED AS A DETAILED DESCRIPTION OF ALL WORK.
2. DUST IS TO BE CONTAINED WITHIN THE WORK AREA. COORDINATE WITH MECHANICAL
PHASING TO KEEP DUST OUT OF DUCTWORK AND MINIMIZE THE SPREAD OF
CONSTRUCTION DUST.
3. REMOVE ALL MECHANICAL, PLUMBING, AND ELECTRICAL NOT NOTED FOR REUSE AND
CAP. SEE MPE DEMOLITION PLANS.
4. ALL COLUMNS, BEAMS, BRACING, AND STRUCTURAL ELEMENTS TO REMAIN UNLESS
OTHERWISE NOTED.
5. EXISTING 3-HOUR STRUCTURAL FIREPROOFING TO REMAIN. REPAIR AS REQUIRED TO
MAINTAIN RATING. (SEE SPECIFICATIONS FOR THIRD PARTY TESTING.) EXISTING STEEL
COLUMNS ARE PROTECTED W/ GYPSUM BLOCK/BOARD. EXISTING STEEL BEAMS & DECK
ARE PROTECTED W/ SPRAY APPLIED FIREPROOFING.
6. COORDINATE WITH VA PROJECT ENGINEER REGARDING PHASING OF DEMOLITION
AFFECTING OTHER FLOORS / BUILDING AREAS. ADJACENT FLOORS & BUILDING AREAS
WILL BE OCCUPIED AND ARE TO REMAIN OPERATIONAL DURING CONSTRUCTION.
7. AT COMPLETION OF DEMOLITION, COORDINATE WITH VA PROJECT ENGINEER FOR
INSPECTION AND REVIEW OF EXISTING CONDITIONS & MPE ITEMS TO REMAIN.
8. UNLESS NOTED OTHERWISE, ALL EXISTING CEILING SYSTEMS IN AREA OF WORK ARE TO
BE REMOVED COMPLETE.
9. UNLESS NOTED OTHERWISE, ALL CEILING MOUNTED FIXTURES AND EQUIPMENT IN AREA
OF WORK TO BE REMOVED COMPLETE.
10. SEE MPE FOR DEMOLITION OF EXISTING FIRE ALARM AND SPRINKLER SYSTEM
COMPONENTS.
11. EXISTING 2-HOUR FLOOR & CEILING SEPARATIONS TO REMAIN. REPAIR AS REQ'D TO
MAINTAIN RATING LEAVING NO OPEN PENETRATIONS AT CLOSE OF DAILY ACTIVITIES. USE
TEMPORARY SYSTEM (2-HOUR RATED) WHERE PENETRATIONS ARE TO ACCESSED LATER
FOR ONGOING WORK.
PLAN NORTH
NURSE MGR
4C163
STRETCHER / EQUIP.
STORAGE
4C111
CCU/MICU BED
4C109
CCU/MICU ISO BED
4C107A CCU/MICU BED
4C106
PCU BED
4C103
PCU BED
4C101
CONF./STOR. ROOM
4C140
PCU/ISO BED
4C122A
PCU BED
4C120
PCU BED
4C118
CCU/MICU ISO BED
4C117A
CCU/MICU BED
4C116
CCU/MICU BED
4C115
CCU/MICU BED
4C114
CCU/MICU BED
4C113
CCU/MICU BED
4C112
ON CALL
4C161
CLEAN UTILITY
4C164 LINEN
4C165
STAFF TOILET
4C156
SOILED UTILITY
4C160
BREAK ROOM
4C152
T.S.C.
4C121 NOURISHMENT
4C147
H.A.C.
4C148
CONFERENCE
4C145
MED GAS
4C159
CLEAN UTILITY
4C151
LINEN
4C144
STAFF TOILET
4C143
NURSE SUPER/CLIN.
PHARM
4C153
SOILED UTILITY
4C150
CORRIDOR
4C170
CORRIDOR
4C166
STAIR
BATH
4C102A
BATH
4C103A
ANTEROOM
4C107
75 LOCKERS
BATH
4C101A
PCU/ISO BED
4C100A
PCU BED
4C102
PCU BED
4C119
A
A
B
B
F
F
G
G
H
H
I
I
J
J
K
K
C
C
1 1
2 2
3 3
4 4
CCU/MICU ISO BED
4C108A
BATH
4C118A
BATH
4C119A
BATH
4C120A
BATH
4C122B
G 2 5
E 2 5
G 2 5
G 2 5
C 2 3
F3/4
F 2 5G
2 5
E 2 5
G 2 5
G 2 5
A 1 1
A 3 6
G 2 5
G 2 5
G 2 5
BIOMED
4C155
27222
2 2 27
HVAC
4C131
13.1
14 14
169169169
G 2 5
CCU/MICU BED
4C105
CCU/MICU ISO BED
4C104A
D
D
3 3
3 3 3 3
3 3 3
PROCEDURE ROOM
4C141
CONF. ROOM
4C139
MEDS RM
4C142
BATH
4C100B
ANTE ROOM
4C100
ANTE ROOM
4C122
NURSE'S STATION
4C149
NURSE'S STATION
4C149
STORAGE
4C157
MED RM
4C158
ANTE ROOM
4C117
ANTEROOM
4C108
A 1 1
A 1 1
A 3 6
A 1 1
A 1 1
A 1 1
A 3 6
A 1 1
A 1 1
A 1 1
A 1 1
A 3 6
A 1 1
A 1 1
A 1 1
A 1 1
A 1 1
A 3 6
A 1 1
A 1 1
A 3 6
A 1 1
A 1 1
169 169 169 169
169 169 169
169 169
G 2 5
G 2 5
G 2 5
G 2 5 G
2 5 14
G 2 5
E 2 5
E 2 5
E 2 5
G 2 5
XFEC
E 2 5
E 2 5
A 1 1
A 1 1
169.1
169.1
A
B
A
B B
A
B B
B B
A
B B
A
B
A
B B
B B
A
B B
A
B B
A A
B B
G 2 5C
2 3
F3/4 F3/4
G 2 5
F3/4
F3/4
G 2 5
ANTE ROOM
4C104
CORRIDOR
4C171
CORRIDOR
4C172
CORRIDOR
4C167
CORRIDOR
4C169
CORRIDOR
4C168
39.1
G 2 5
FEC
FECG
2 5
A 1 1
FEC
CCU/MICU BED
4C110
D 2 5
F3/4
F3/4
F3/4
131313
13 13 13
16161616
16 16 16 16
A 1 1
B
H 2 7
F1-1/2
16161616161616
161616161616 14 14 14 14 14 14
14 14 14 14
14 1414 14 14 14 14
14 14 14 14
F3/4
1. PATCH AND REPAIR ANY AREA AFFECTED BY DEMOLITION. MATCH ADJOINING FINISHES
TO REMAIN. PREP AS REQUIRED TO RECEIVE NEW FINISHES.
2. PROVIDE BLOCKING AS REQUIRED FOR WALL MOUNTED CASEWORK, EQUIPMENT,
HANDRAILS, TOILET ACCESSORIES. SEE MPE. SEE ENLARGED EQUIPMENT PLANS. SEE
FINISH PLANS. SEE E3/AS503 FOR TYP. BLOCKING DETAIL.
3. EXISTING FIRE BARRIERS TO BE REPAIRED AS REQUIRED TO MAINTAIN RATING.
4. NEW AND EXISTING PENETRATIONS THROUGH NEW AND EXISTING FIRE AND SMOKE
BARRIERS TO BE PROPERLY SEALED AND PROTECTED AS REQUIRED TO MAINTAIN
RATINGS. UL LISTED DETAILS ARE REQUIRED AT ALL PENETRATIONS. SEE MP&E.
5. EXISTING THREE-HOUR STRUCTURAL FIRE PROOFING TO REMAIN IN PLACE. REPAIR AS
REQUIRED TO MAINTAIN CONTINUITY AND FIRE RATING. SEE SPECIFICATION FOR THIRD
PARTY TESTING. EXISTING STEEL COLUMNS ARE PROTECTED W/ GYPSUM BLOCK/BOARD.
EXISTING STEEL BEAMS & DECK ARE PROTECTED W/ SPRAY APPLIED FIREPROOFING.
6. VERIFY FIRE RATINGS INDICATED AS EXISTING. IMMEDIATELY NOTIFY VA PROJECT
ENGINEER OF ANY DISCREPANCIES.
7. PATCH FLOOR / CEILING SLABS AS REQUIRED FOR FIRE & SMOKE RESISTANCE AT
REMOVED / ABANDONED CHASES AND FLOOR PENETRATIONS. SEE MPE. SEE
STRUCTURAL SHEET S1 FOR PATCH DETAILS.
8. PROVIDE NEW FLOOR / CEILING SLAB PENETRATIONS AS REQUIRED FOR MPE. SEE
MPE. SEE STRUCTURAL FOR PENETRATION DETAILS WHERE REQUIRED.
9. PROVIDE FLOOR LEVELING AS REQUIRED AT REMOVED FLOOR TILE LOCATIONS.
10. SEE DIMENSION PLAN AND ENLARGED PLANS FOR DIMENSIONS. SEE AS601 FOR
DOOR & WINDOW SIZES.
11. ANY EXISTING WALL TO REMAIN SHALL BE UPGRADED FOR FIRE & SMOKE
REQUIREMENTS WHERE INDICATED.
12. CARRIERS TO BE PROVIDED IN WALLS AT ALL WALL MOUNTED LAVS, SINKS, &
TOILETS. SEE PLUMBING. VERIFY REQUIRED CLEARENCES AND REPORT ANY
DISCREPENCES TO AREA.
13. FLOOR ABOVE & BELOW IS A TWO-HOUR FIRE BARRIER. NEW & EXISTING
PENETRATIONS TO BE PROPERLY SEALED & PROTECTED AS REQUIRED TO MAINTAIN
RATING. UL LISTED DETAILS ARE REQUIRED FOR ALL PENETRATIONS. SEE MPE.
14. AT EXISTING COLUMNS, MAINTAIN EXISTING FIREPROOFING. PROVIDE MINIMUM
ADDITIOINAL FURRING AND GYP. BD. FINISH AS REQ'D TO ALIGN W/ NEW CONSTRUCTION.
15. SEE AS601 FOR DOOR HARDWARE SCHEDULE.
PROVIDE FLOOR LEVELING AS REQUIRED AT EXISTING SLAB DEPRESSION /
REMOVED TILE LOCATION.
SEE FINISH PLAN FOR SHOWER FLOOR FINISH AND THRESHOLD. BUILD UP
EXISTING FLOOR SLAB SUCH THAT SHOWER FLOOR SLOPES TO DRAIN AT 1/4"
PER FT. MIN. SEE SHOWER FLOOR DETAIL B8/AS503.
COLUMN HEADWALL UNIT AT THIS LOCATION. SEE B8/AS202 & ENLARGED PLANS
FOR UNIT CONFIGURATIONS.
REPLACE EXISTING GLAZING W/ INSULATING SPANDREL UNITS. PACK
VOID BETWEEN WINDOWS & NEW WALL W/ BATT INSULATION.
EXISTING EXPANSION JOINT. ADUJST / REINSTALL METAL COVER PLATE AS
REQUIRED TO ACCOMODATE NEW FINISHES.
MODIFY EXISTING STAINLESS STEEL WINDOW SILL TRIM AS REQUIRED TO
ACCOMODATE REDUCED WALL WIDTH.
CARD READER TO BE INSTALLED AT DOOR. SEE ELECTRICAL.
9 EXTEND EXISTING GYP BOARD FINISH ON BOTHS SIDES OF WALLS IN
TELECOMUNICATIONS (T.S.C.) TO UNDERSIDE OF DECK ABOVE FOR ROOM
SECURITY. PROVIDE ADDITIONAL METAL STUD FRAMING AS REQUIRED.
MED GAS ZONE VALVE BOX LOCATION. SEE PLUMBING DWGS.10
NOT USED11
EXISTING DOOR & DOOR HARDWARE TO REMAIN. DOOR & FRAME TO BE
REPAINTED COLOR P-6. SEE FINISH SCHEDULE.
WINDOW PROVIDED AS PART OF BASE BID. SEE ALTERNATE #2 FOR LCD
GLAZING & ASSOCIATED ELECTRICAL WORK.
WINDOW PROVIDED AS PART OF BASE BID. SEE ALTERNATE #6 FOR LCD GLAZING
& ASSOCIATED ELECTRICAL WORK.
PROVIDE SLIDING GLASS ICU DOOR W/ COMPLETE LCD GLAZING SYSTEM AT
THIS LOCTION AS PART OF BASE BID.
PROVIDE DOOR W/ LCD GLAZING AS PART OF ALERNATE #1. SEE AS601 FOR
ALTERNATE & BASE BID DOOR & FRAME TYPES. BASE BID: STANDARD GLAZED DOOR.16
NEW LOCATION FOR RELOCATED EXISTING PNEUMATIC TUBE STATION.
PROTECT DURING CONSTRUCTION. VA TUBE STATION VENDOR IS TO BE
ENGAGED FOR REQUIRED WORK & INCLUDED IN GC'S CONSTRUCTION
CONTRACT. CONTACT VENDOR FOR EXACT SCOPE OF WORK (PEVCO
SYSTEMS 800-738-2699). SEE ELECTRICAL. NEW FRAMED ROUGH
OPENING/CHASE TO BE SIZED PER SYSTEM VENDOR'S REQUIREMENTS.
TUBE SYSTEM PIPING TO BE CONFIGURED AS REQUIRED FOR
RELOCATION. PROVIDE TWO 6" DIA. PENETRATIONS THROUGH FLOOR SLAB
FOR RELOCATED TUBE RISERS. EXISTING PNEUMATIC TUBE RISERS
ABOVE THIRD FLOOR CEILING TO BE REROUTED TO NEW PENETRATIONS IN
4th FLOOR SLAB. PNEUMATIC TUBE RISERS ON 4th FLOOR TO BE
REROUTED TO RELOCATED TUBE STATION & ABOVE CEILING TO EXISTING
RISER PENETRATION THROUGH 5th FLOOR SLAB. PROTECT FLOOR
PENETRATIONS AS REQUIRED TO MAINTAIN FIRE-RATING.
EXISTING 20 MIN. DOUBLE EGRESS DOORS TO BE REPLACED W/ TEMPORARY 1-
HOUR FIRE RATED DOORS FOR DURATION OF CONSTRUCTION. NEW FIRE RATED
AUTOMATIC DOUBLE EGRESS DOORS TO BE PROVIDED AS PART OF NEW WORK.
FOR DURATION OF CONSTRUCTION, SIGN TO BE PROVIDED ON OUTSIDE OF
DOORS INDICATING "NO EXIT". EXISTING SIGNS & DIRECTIONAL ARROWS
POINTING TO AREA OF WORK ARE TO BE COVERED.
PUSH BUTTON LOCATION FOR NEW AUTOMATIC DOOR.19
FEC FIRE EXTINGUISHER CABINET
HATCH REPRESENTS APPROXIMATE AREA OF REQUIRED
FLOOR LEVELING AT EXISTING SLAB DEPRESSION.
XFEC EXISTING FIRE EXTINGUISHER CABINET
SMOKE PARTITION (SEE FLOOR PLANS
FOR WALL AND DOOR DESIGNATIONS)
1 HR. FIRE AND SMOKE BARRIER PER UL #419
(SEE FLOOR PLANS FOR WALL AND DOOR
DESIGNATIONS)
1 HR. FIRE BARRIER PER UL #419 (SEE FLOOR
PLANS FOR WALL AND DOOR DESIGNATIONS)
EXISTING 1 HR. FIRE AND SMOKE BARRIER
EXISTING 2 HR. FIRE AND SMOKE BARRIER
1 2 43 5 6 7 8 9
D
EP
AR
TM
EN
T
O F
VE
TE
R
AN
S
AF
FA
IR
SDATE
PROJECT NO.
DRAWING NO.
FILE NAME
A:Projects/2006- 1111.06
PROJECT TITLE
BUILDING NUMBER CHECKED DRAWN
WILLIAM JENNINGS BRYAN DORN
V A MEDICAL CENTER
COLUMBIA, SOUTH CAROLINA
DRAWING TITLE
APPROVED : CHIEF, LOGISTICS
APPROVED : MED CTR SAFETY MANAGER
APPROVED : INFECTION CONTROL
APPROVED : CHIEF OF STAFF
APPROVED : ASSOC DIR FOR PATIENT/
NURSING SERVICES
APPROVED : DIR., INFRASTRUCTURE
APPROVED : ASSOCIATE DIRECTOR
1 2 43 5 6 7 8 9
A
B
C
D
E
F
DATEREVISIONS
APPROVED : MEDICAL CENTER DIRECTOR
FINAL CONTRACT DOCUMENTS
FULLY SPRINKLERED
APPROVED : STATION ENERGY MANAGER
05.21.10
544-322
AS101
RELOCATE ICU TO 4 EAST
TNS/PAF KJT
REFERENCE FLOOR PLAN
GENERAL NOTES
SCALE: 1/8" = 1'-0"AS101
FLOOR PLAN- REFERENCEA1
LIFE SAFETY WALL DESIGNATIONS
KEY NOTES
PLAN NORTH
LEGEND
A
B
B
F
F
G
G
H
H
I
I
J
J
K
K
C
C
1 1
2 2
3 3
4 4
NURSE MGR
4C163
STRETCHER / EQUIP.
STORAGE
4C111
CCU/MICU BED
4C109
CCU/MICU ISO BED
4C107A
CCU/MICU BED
4C106
PCU BED
4C101
CONF./STOR. ROOM
4C140
PCU/ISO BED
4C122APCU BED
4C120
PCU BED
4C118
CCU/MICU ISO BED
4C117ACCU/MICU BED
4C116
CCU/MICU BED
4C115CCU/MICU BED
4C114
CCU/MICU BED
4C113
CCU/MICU BED
4C112
ON CALL
4C161
CLEAN UTILITY
4C164
LINEN
4C165 STAFF TOILET
4C156
SOILED UTILITY
4C160
BREAK ROOM
4C152
T.S.C.
4C121 NOURISHMENT
4C147
H.A.C.
4C148
CONFERENCE
4C145
MED GAS
4C159
CLEAN UTILITY
4C151
LINEN
4C144
STAFF TOILET
4C143
NURSE SUPER/CLIN.
PHARM
4C153
SOILED UTILITY
4C150
CORRIDOR
4C170
CORRIDOR
4C166
STAIR
BATH
4C102A
BATH
4C103A
ANTEROOM
4C107
75 LOCKERS
BATH
4C101A
PCU/ISO BED
4C100A
PCU BED
4C102
PCU BED
4C119
11' - 8" 14' - 8" 14' - 9" 14' - 9 1/2" 14' - 11 1/2" 14' - 7" 14' - 9" 14' - 7" 15' - 1" 14' - 11" 15' - 2" 14' - 5"
CCU/MICU ISO BED
4C108A
BATH
4C118A
BATH
4C119A
BATH
4C120A
BATH
4C122B
AS113
A1
AS115
A1
BIOMED
4C155
VE
RI
FY
9"
CL
EA
R
8'
- 0
5"
2' - 6 1/2"
VERIFY
8' - 1 1/2" 26' - 0" 6' - 5" 28' - 9" 6' - 5"
AS114
A1
VE
RI
FY
4"
1/ 2"
7"
STORAGE
4C157
MED RM
4C158
PCU BED
4C103
CCU/MICU ISO BED
4C104A
CCU/MICU BED
4C105
HVAC
4C131
ANTEROOM
4C108
D
D
VERIFY
26' - 4" 14' - 9" 14' - 9 1/2" 14' - 11 1/2" 14' - 7" 14' - 9" 14' - 9" 14' - 11" 14' - 11" 15' - 2" 14' - 5"
AS110
A3
AS110
A6
ANTE ROOM
4C104
ANTE ROOM
4C100
PROCEDURE ROOM
4C141
CONF. ROOM
4C139
MEDS RM
4C142
NURSE'S STATION
4C149
NURSE'S STATION
4C149
ANTE ROOM
4C122
BATH
4C100B
ANTE ROOM
4C117
AS110
A1
AS111
A1
C
LE
AR
8'
0"
VE
R
IF
Y
8'-0" CLEAR
C
LE
AR
8'
0"
3' - 10"
CLE
AR8'
- 0
CLEAR
6' - 0"
C
LE
AR
8'
0"
CLEAR
8' - 0"
VE
R
IF
Y
/2
C
LE
AR
8'
0"
27' - 6" 6' - 5"
C
LE
AR
8'
0"
8' -0
" C
LE
AR
VE
R
IF
Y
/2
CLE
AR8'
- 0
3' - 1"
CLEAR
8' - 0"
3' - 3"
1' - 3"
1'
3"
AS111
A4
8' -0
" C
LE
AR 10' - 6"
8' - 1"
AS115
A5
AS112
A4
XFEC
CLEAR
6' - 0"
CLEAR
6' - 0"
9'
1"
/2
AS112
A1
1.1
9.1
7.1
6 6
1.1
174' - 3"
174' - 3"
1.1 1.1
9.1
1.1
9.1
6 6
5 9
1.1 1.1
1.1
1.1
1.1 1.1
9.1
1.1
9.1
1.1
9.1
1.1
9.1
3 2
7.1
FEC
FEC
FEC
8 8 8 8
8 88
6 55
6 7
1.1
1.1
CCU/MICU BED
4C110
1. PRIOR TO CONSTRUCTION, CONTRACTOR TO THOROUGHLY FIELD VERIFY ALL
DIMENSIONS AND NOTIFY VA PROJECT ENGINEER OF PROBLEM DISCREPANCIES BEFORE
PROCEEDING.
2. DIMENSIONS ARE FROM FINISH FACE OF EXISTING MATERIAL TO FACE OF STUD AT
NEW WALLS UNLESS OTHERWISE NOTED. ASSUME 5" NOMINAL WIDTH FOR NEW WALLS
UNLESS OTHERWISE NOTED.
3. "CLEAR" DIMENSIONS ARE MEASURED FROM FINISH FACE OF WALL TO FINISH FACE OF
WALL TO INDICATE MINIMUM CLEARANCE REQUIRED.
4. ADJUST DIMENSIONS TO ALIGN NEW WALLS WITH EXISTING CONSTRUCTION. "VERIFY"
DIMENSIONS INDICATE FLEX AREAS FOR FIELD ADJUSTMENTS AND ALIGNMENT W/
EXISTING CONSTRUCTION. NOTIFY VA PROJECT ENGINEER OF DISCREPANCIES
EXCEEDING 2".
5. SEE ENLARGED PLANS FOR ADDITIONAL DIMENSIONS AND NOTES
6. UNLESS SHOWN & DIMENSIONED OTHERWISE, DOOR OPENING ON HINGE SIDE TO BE
LOCATED 4" FROM ADJACENT WALL.
7. SEE GI001, AS101 & AS601 FOR NOTES REGARDING LCD GLAZING @ INTERIOR
WINDOWS & SLIDING GLASS ICU DOORS TO BE PROVIDED AS PART OF BID ALTERNATES.
SMOKE PARTITION (SEE FLOOR PLANS
FOR WALL AND DOOR DESIGNATIONS)
1 HR. FIRE AND SMOKE BARRIER PER UL #419
(SEE FLOOR PLANS FOR WALL AND DOOR
DESIGNATIONS)
1 HR. FIRE BARRIER PER UL #419 (SEE FLOOR
PLANS FOR WALL AND DOOR DESIGNATIONS)
EXISTING 1 HR. FIRE AND SMOKE BARRIER
EXISTING 2 HR. FIRE AND SMOKE BARRIER
FEC FIRE EXTINGUISHER CABINET
XFEC EXISTING FIRE EXTINGUISHER CABINET
1 2 43 5 6 7 8 9
D
EP
AR
TM
EN
T
O F
VE
TE
R
AN
S
AF
FA
IR
SDATE
PROJECT NO.
DRAWING NO.
FILE NAME
A:Projects/2006- 1111.06
PROJECT TITLE
BUILDING NUMBER CHECKED DRAWN
WILLIAM JENNINGS BRYAN DORN
V A MEDICAL CENTER
COLUMBIA, SOUTH CAROLINA
DRAWING TITLE
APPROVED : CHIEF, LOGISTICS
APPROVED : MED CTR SAFETY MANAGER
APPROVED : INFECTION CONTROL
APPROVED : CHIEF OF STAFF
APPROVED : ASSOC DIR FOR PATIENT/
NURSING SERVICES
APPROVED : DIR., INFRASTRUCTURE
APPROVED : ASSOCIATE DIRECTOR
1 2 43 5 6 7 8 9
A
B
C
D
E
F
DATEREVISIONS
APPROVED : MEDICAL CENTER DIRECTOR
FINAL CONTRACT DOCUMENTS
FULLY SPRINKLERED
APPROVED : STATION ENERGY MANAGER
05.21.10
544-322
AS102
RELOCATE ICU TO 4 EAST
TNS/PAF KJT
DIMENSION FLOOR PLAN
SCALE: 1/8" = 1'-0"AS102
FLOOR PLAN - DIMENSIONA2
LIFE SAFETY WALL DESIGNATIONS
PLAN NORTH
TRUE NORTH
GENERAL DIMENSION NOTES
LEGEND
WALL TYPE LEGEND
WALL TYPES
TYPE
MARK
FIRE
BARRIER
RATING DESCRIPTION DETAIL
1 EXISTING INTERIOR PARTITION. PATCH
AS REQ'D FOR CONTINUOUS GYP BRD
FINISH AND ALIGN W/ NEW ADJACENT
CONSTRUCTION. NEW & EXISTING GYP
BRD TO BE PAINTED (P-1). SEE FINISH
SCHEDULE
1.1 EXISTING EXTERIOR WALL. PATCH AS
REQ'D. AT REMOVED INTERIOR
PARTITION LOCATIONS FOR
CONTINUOUS GYP BRD FINISH. NEW &
EXISTING GYP BRD TO BE PAINTED
(P-1). SEE FINISH SCHEDULE. SEE
FINISH PLAN FOR NEW RIGID VINYL
SHEET LOCATIONS.
2 1 HR FIRE
/ SMOKE
EXISTING 1-HOUR FIRE/SMOKE
BARRIER. NEW AND EXISTING
PENETRATIONS TO BE PROPERLY
SEALED AND PROTECTED TO
MAINTAIN RATING. PATCH AS REQ'D TO
MAINTAIN RATING AT REMOVED WALL
LOCATIONS. NEW & EXISTING GYP BRD
TO BE PAINTED ON
CORRIDOR/PATIENT ROOM/EQUIP
STORAGE SIDE (P-1). SEE FINISH
SCHEDULE. SEE FINISH PLAN FOR
RIGID VINYL SHEET LOCATIONS.
3 2 HR FIRE
/ SMOKE
EXISTING 2-HOUR FIRE/SMOKE
BARRIER. NEW AND EXISTING
PENETRATIONS TO BE PROPERLY
SEALED AND PROTECTED TO
MAINTAIN RATING.
4 EXISTING WALL TO BE UPGRADED TO
SMOKE PARTITION.
B3/AS301
SIMILAR
5 NEW WALL, 3 5/8" METAL STUDS, 3-1/2"
SOUND ATTENUATION BLANKETS, W/
5/8" GYP BRD EACH SIDE UNLESS
SHOWN OTHERWISE.
6 NEW SMOKE PARTITION W/ 3-1/2"
SOUND ATTENUATION BLANKETS.
PROVIDE 6" METAL STUDS AT
PLUMBING WALLS.
7 1 HR
UL# 419
NEW 1-HOUR FIRE BARRIER W/ 3-1/2"
SOUND ATTENUATION BLANKETS.
PROVIDE 6" METAL STUDS AT
PLUMBING WALLS
7.1 1 HR FIRE
/ SMOKE
UL#419
NEW 1-HOUR FIRE/SMOKE BARRIER W/
3-1/2" SOUND ATTENUATION
BLANKETS. PROVIDE 6" METAL STUDS
AT PLUMBING WALLS
8 NEW CHASE W/ 3-1/2" SOUND
ATTENUATION BLANKETS. CHASE TO
ACCOMODATE CARRIERS AT WALL
MOUNTED LAVS, SINKS, & TOILETS,
ETC. CONSTRUCT AS SMOKE
PARTITION WHERE REQ'D.
9 NEW PLUMBING WALL, W/ 3-1/2" SOUND
ATTENUATION BLANKETS. PROVIDE 6"
METAL STUDS W/ 5/8" GYP BD EACH
SIDE.WALL TO ACCOMODATE
CARRIERS AT WALL MOUNTED LAVS.
9.1 NEW PLUMBING WALL, W/ 3-1/2" SOUND
ATTENUATION BLANKETS. PROVIDE 8"
WIDE METAL STUD FRAMING W/ 5/8"
GYP BD EACH SIDE.WALL TO
ACCOMODATE CARRIERS AT WALL
MOUNTED LAVS.
B5/AS301
SIMILAR
B3/AS301
B1/AS301
B1/AS301
SIMILAR
B7/AS301
B5/AS301
B
B
F
F
G
G
H
H
I
I
J
J
K
K
C
C
1 1
2 2
3 3
4 4
STRETCHER / EQUIP.
STORAGE
4C111
CCU/MICU BED
4C109
CCU/MICU ISO BED
4C107A CCU/MICU BED
4C106
PCU BED
4C103
PCU BED
4C102
PCU BED
4C101
PCU/ISO BED
4C100A
CONF./STOR. ROOM
4C140
SOILED UTILITY
4C150
NURSE SUPER/CLIN.
PHARM
4C153
STAFF TOILET
4C143
CLEAN UTILITY
4C151
LINEN
4C144
CONFERENCE
4C145
H.A.C.
4C148
NOURISHMENT
4C147
BREAK ROOM
4C152
T.S.C.
4C121
SOILED UTILITY
4C160
CLEAN UTILITY
4C164
LINEN
4C165
ON CALL
4C161
STAFF TOILET
4C156
CORRIDOR
4C166
CCU/MICU BED
4C112
CCU/MICU BED
4C113
CCU/MICU BED
4C114
CCU/MICU BED
4C115
CCU/MICU BED
4C116
CCU/MICU ISO BED
4C117A
PCU BED
4C118
PCU BED
4C119
PCU BED
4C120
PCU/ISO BED
4C122A
BIOMED
4C155
L
3 3
CCU/MICU ISO BED
4C108A
9' - 0"
9' - 0"
9' - 0"
AS104
D4
AS104
A4
7' - 6"
9' - 0"
7' - 6"
AS104
D3
AS104
D1
NURSE MGR
4C163
BATH
4C103A
BATH
4C102A BATH
4C101A
BATH
4C122BBATH
4C120A
BATH
4C119ABATH
4C118A
7' - 6" 7' - 6"
AS104
A1
D
D
9' - 0"
9' - 0"
ANTE ROOM
4C100
CCU/MICU ISO BED
4C104A
ANTE ROOM
4C104
CCU/MICU BED
4C105
ANTEROOM
4C107
ANTEROOM
4C108
9' - 0"
9' - 0" 9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
7' - 6"
9' - 0" 9' - 0" 9' - 0"
9' - 0"
7' - 6"
9' - 0"
7' - 6"
BATH
4C100B
ANTE ROOM
4C122
7' - 6"
9' - 0"
7' - 6"
7' - 6"
9' - 0"
9' - 0"
9' - 0"
ANTE ROOM
4C117
9' - 0"
33333 9' - 0" 9' - 0"
9' - 0" 9' - 0"
4 4 4
7' - 6"STORAGE
4C157
MED GAS
4C159
NURSE'S STATION
4C149
MEDS RM
4C142
9' - 0"
9' - 0"
9' - 0"
8' - 0"
7' - 0"
9' - 0"
9' - 0" 9' - 0" 9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0" 9' - 0"
9' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0" 8' - 0"
8' - 0"
8' - 0" 8' - 0"
8' - 0"
8' - 0" 8' - 0"
8' - 0"
8' - 0"8' - 0"
8' - 0"
8' - 0"
9' - 0"
9' - 0"
7' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"9' - 0"
L
L
L
L
L
L L
L L
L
L L
L
L
L
L
L L
L
9' - 0" 9' - 0" 9' - 0"
7' - 6"
L
L
L L L
L
L L
L
L
L
L
LL
LL
LLL
9' - 0"
9' - 0"
L
MED RM
4C158
AS104
A3
9' - 0"
PROCEDURE ROOM
4C141
CONF. ROOM
4C139
9' - 0"
C C C C C C
C C C C
CCCC
CCCCCC
L
L
HVAC
4C131 P-3 P-4
P-4P-3P-4
P-4
P-3 P-4 P-3
P-4 P-3
P-2
P-2
P-2
P-2
P-2
7'
7'
C
7' - 0"
7' - 0"
7' - 0"
7' - 0" 7' - 0"
7' - 0" 7' - 0"
7' - 0"
7' - 0"
7' - 0"7' - 0"
7' - 0"7' - 0"7' - 0"
7' - 0"
7' - 0"
7' - 0"
7' - 0"
7' - 0"
7' - 0"
7' - 0"
7' - 0"
7' - 0"
CCU/MICU BED
4C110
TVW TVW TVW TVW
TVW
TVW
TV
W
TVW TVW
TVW TVW
TV
W
TVWTVWTVW
TVW
TVW
TVW
TVW
TVW
TVW
TV
W
TV
W
TV
W
6666666
6 6 6 6 6 6
6 6 6 6
P-2
P-2
TV
W
777777
7 7 7 7 7 7
7 7 7 7
CORRIDOR
4C168
CORRIDOR
4C170
CORRIDOR
4C167
777 77 77
7 7 7 7 7 7
7 7 7 7
X' - X"
RECESSED LIGHT FIXTURE. SEE MPE.
2x4 FLUORESCENT LIGHT FIXTURE. SEE ELEC.
2x4 FLUORESCENT LIGHT FIXTURE WITH EMERGENCY BACKUP. SEE ELEC.
VIDEO CAMERA. SEE ELECTRICAL. SEE ALTERNATE #4. BASE BID: OMIT VIDEO
SURVEILLANCE SYSTEM.
WALL MOUNTED TV BRACKET. ELECTRICAL OUTLETS TO BE CONCEALED
BEHIND TV's.
INTERNALLY ILLUMINATED EXIT SIGN. SEE MPE.
2x2 LAY-IN ACOUSTICAL CEILING SYSTEM. SEE FINISH SCHEDULE.
PAINTED GYP. BOARD SOFFIT. SEE AS302. PAINT ALL SIDES P-1 UNLESS
OTHERWISE NOTED.
PATIENT LIFT SYSTEM. SOLE SOURCE ITEM. MAIN CARRYING RAILS TO BE
LOCATED BELOW CEILING GRID.
CUBICLE CURTAIN TRACK. SEE SPEC SECTION 10 21 23.
PAINTED MOISTURE RESISTANT GYP. BOARD CEILING AT SHOWER
LOCATIONS.
HVAC SUPPLY GRILL. SEE MPE.
HVAC RETURN GRILL. SEE MPE.
HVAC EXHAUST GRILL. SEE MPE.
FINISH CEILING HEIGHT.
ACCESS PANEL. SEE AS104.
SPEAKER. SEE MPE.
CEILING MOUNTED SIGN. SEE AS703.
STRIP LIGHT FIXTURE. SEE ELECTRICAL.
C
L
TVW
NO WORK IN THIS AREA.
NO FINISH CEILING IN THIS AREA. SEE MPE REGARDING INFO ON CEILING DEVICES.
CLEAN ROOM TYPE ACT CEILING IN THIS SPACE. SEE FINISH SCHEDULE.
4 GYP BRD CEILING (PAINTED P-5) ON MTL. CEILING JOISTS. SEE DETAILS 6&7 / SHEET
S1 FOR CEILING FRAMING DETAILS.
CEILING MOUNT MED GAS OUTLET LOCATION. SEE MPE.5
SEE ALTERNATE #1 (SHEET GI001) REGARDING LCD GLAZING IN DOORS.
CUBICLE CURTAINS SHALL NOT BE PROVIDED AT THIS LOCATION IF LCD
GLAZING IS PROVIDED AT THIS LOCATION. BASE BID: PROVIDE CUBICLE
CURTAINS AS SHOWN.
SEE ALTERNATES #2 & #6 REGARDING LCD GLAZING AT INTERIOR
WINDOWS. IF LCD GLAZING IS PROVIDED, CUBICLE CURTAINS SHALL NOT
BE PROVIDED. BASE BID: PROVIDE CUBICLE CURTAINS AS SHOWN.
SMOKE PARTITION (SEE FLOOR PLANS
FOR WALL AND DOOR DESIGNATIONS)
1 HR. FIRE AND SMOKE BARRIER PER UL #419
(SEE FLOOR PLANS FOR WALL AND DOOR
DESIGNATIONS)
1 HR. FIRE BARRIER PER UL #419 (SEE FLOOR
PLANS FOR WALL AND DOOR DESIGNATIONS)
EXISTING 1 HR. FIRE AND SMOKE BARRIER
EXISTING 2 HR. FIRE AND SMOKE BARRIER
1 2 43 5 6 7 8 9
D
EP
AR
TM
EN
T
O F
VE
TE
R
AN
S
AF
FA
IR
SDATE
PROJE…