WOODLANDS

T-28

BUILDING 100

I-77

CONTRACTORS ENTRY

NOT TO SCALE

106. PSYCHIATRY

104. MEDICAL SCHOOL LECTURE HALL

103. NURSING HOME CARE UNIT

101. MEDICAL SCHOOL LIBRARY

100. 400 BED HOSPITAL, MEDICAL & SURGICAL

T-28. MEDICAL SCHOOL STAFF & RESEARCH

22. ADMINISTRATION BUILDING

20. ENGINEERING OFFICES & SHOPS

10. ADMINISTRATION

9. RESEARCH VA

8. BOILER PLANT

7. WAREHOUSE

6. RESEARCH VA

5. AUDITORIUM/ MAIL ROOM

4. USC MEDICAL SCHOOL RESEARCH

3. PSYCHIATRIC BUILDING

2. MEDICAL SCHOOL

1. BASIC SCIENCE BUILDING

BUILDING

VA

5 21

2087106

ROAD

BYRON

BACK GATE

PARKING

PARKING

GATE

SIDE

ROAD

OLD

STATION

B.P.

COLUMBIA

TO

SHOPPING CENTER

CEDAR TERRACE

SHOPPING CENTER

LANDMARK SQUARE

PARKING

USC-MS

U.S. HIGHWAY 76 & 378

ROAD

LEESBURG

SUMTER

TO

AND OUT OF ECC EACH DAY.

100. CONTRACTOR MUST CHECK IN

LOCATED IN BASEMENT OF BUILDING

ENGINEERING CONTROL CENTER (ECC)

AREA OF WORK - 4th FLOOR EAST

NORTH

CONTRACTOR STORAGE &

PARKING

TO I-26

I-77

TO 1-20

TO

1-26

GARDEN SPRINGS

YORKSHIRE

G

AR

NERS

"VETERANS MEMORIAL FREEWAY"

BLVD

FORT

BLVD

JACKSON

FER

R

Y R D

VILLAGE POND

BURNSIDE

WOODS

HERITAGE

SHOP RD

BRANDON ACRES

KNOLLWOOD

FIELD

MEADOW

TRACE

HAMPTON

LINE

76oSITE

I-7

NORTH

1 2 43 5 6 7 8 9

D

EP

AR

TM

EN

T

O F

VE

TE

R

AN

S

AF

FA

IR

SDATE

PROJECT NO.

DRAWING NO.

FILE NAME

A:Projects/2006- 1111.06

PROJECT TITLE

BUILDING NUMBER CHECKED DRAWN

WILLIAM JENNINGS BRYAN DORN

V A MEDICAL CENTER

COLUMBIA, SOUTH CAROLINA

DRAWING TITLE

APPROVED : CHIEF, LOGISTICS

APPROVED : MED CTR SAFETY MANAGER

APPROVED : INFECTION CONTROL

APPROVED : CHIEF OF STAFF

APPROVED : ASSOC DIR FOR PATIENT/

NURSING SERVICES

APPROVED : DIR., INFRASTRUCTURE

APPROVED : ASSOCIATE DIRECTOR

1 2 43 5 6 7 8 9

A

B

C

D

E

F

DATEREVISIONS

APPROVED : MEDICAL CENTER DIRECTOR

FINAL CONTRACT DOCUMENTS

FULLY SPRINKLERED

APPROVED : STATION ENERGY MANAGER

05.21.10

544-322

GI001

RELOCATE ICU TO 4 EAST

TNS/PAF PRM

COVER SHEET

CAMPUS MAP OWNER

ARCHITECT

RELOCATE ICU TO 4 EAST (BLDG. 100)

DEPARTMENT OF VETERANS AFFAIRS

PROJECT LOCATION: WILLIAM JENNINGS BRYAN DORN MEDICAL CENTER, COLUMBIA, SOUTH CAROLINA

AS001

AD101

AD102

AS101

AS102

AS103

AS104

AS110

AS111

AS112

AS113

AS114

AS115

AS201

AS202

AS203

AS204

AS205

AS301

AS302

AS501

AS502

AS503

AS601

AS701

AS702

AS703

AS704

ARCHITECTURAL

NUMBER

ABBREVIATIONS & SYMBOLS

DEMOLITION FLOOR PLAN

DEMOLITION REF. CEILING PLAN

REFERENCE FLOOR PLAN

DIMENSION FLOOR PLAN

REFLECTED CEILING PLAN

ENLARGED REF. CLG. PLANS

ENLARGED FLOOR PLANS

ENLARGED FLOOR PLANS

ENLARGED FLOOR PLANS

ENLARGED FLOOR PLANS

ENLARGED FLOOR PLANS

ENLARGED FLOOR PLANS

INTERIOR ELEVATIONS

INTERIOR ELEVATIONS

INTERIOR ELEVATIONS

INTERIOR ELEVATIONS

INTERIOR ELEVATIONS

WALL SECTIONS

SEISMIC REQ'S & CLG. DETAILS

CASEWORK SECTIONS

CASEWORK SECTIONS

SECTIONS & DETAILS

DOOR AND WINDOW SCHEDULE

FINISH PLAN

INTERIOR DETAILS

SIGNAGE

SIGNAGE

TITLE

INDEX OF DRAWINGS

COVER SHEETGI001

LOCATION MAP

STRUCTURAL

GI002 LIFE SAFETY PLAN

FA001

FA101D

FA101

FX001

FX101D

FX101

FIRE PROTECTION

FIRE ALARM LEGEND AND NOTES

FIRE ALARM LEVEL 4 EAST DEMOLITION PLAN

FIRE ALARM LEVEL 4 EAST PLAN

FIRE PROTECTION LEGEND AND NOTES

FIRE PROTECTION LEVEL 4 EAST DEMOLITION

PLAN

FIRE PROTECTION LEVEL 4 EAST PLAN

M001 M101D M101 M102 M104 M201 M301 M302 M501 M601 M701 M702 M703

MECHANICAL

HVAC LEGEND AND GENERAL NOTES

HVAC LEVEL 4 EAST DEMO PLAN

HVAC LEVEL 4 EAST PLAN

PRESSURIZATION PLAN LEVEL 4 EAST

HVAC ROOF EAST PLAN

HVAC LEVEL 4 EAST PIPING PLAN

HVAC LEVEL 4 EAST MECH ROOM PART PLANS

HVAC LEVEL 5 EAST MECH ROOM PART PLANS

HVAC SCHEDULES

HVAC DETAILS

HVAC CONTROLS LEGEND AND NOTES

HVAC CONTROLS - AIR HANDLING UNIT AC-6

HVAC CONTROLS - AIR HANDLING UNIT AC-7

PL001

PL002

PL101

PL102

PL103

PL104

PL111

PL112

PL121

PL122

PL501

PL502

PL503

PL601

PLUMBING

PLUMBING LEGEND AND NOTES

PLUMBING SCHEDULES

PLUMBING LEVEL 3 EAST DEMO PLAN

PLUMBING LEVEL 4 EAST DEMO PLAN

PLUMBING LEVEL 3 EAST SW&V PLAN

PLUMBING LEVEL 4 EAST SW&V PLAN

PLUMBING LEVEL 4 EAST DEMO PLAN

PLUMBING LEVEL 4 EAST WATER PLAN

PLUMBING LEVEL 4 EAST DEMO PLAN

PLUMBING LEVEL 4 EAST MED GAS PLAN

PLUMBING RISER DIAGRAMS

PLUMBING RISER DIAGRAMS

PLUMBING RISER DIAGRAMS

PLUMBING DETAILS

ES001

ES101D

ES101

ES201

ES304D

ES304

ES402

ES501

ES502

ES503

ES504

ES601

ES602

ES603

ELECTRICAL

ELECTRICAL LEGEND AND NOTES

ELECTRICAL LEVEL 4 EAST DEMO PLAN

LIGHTING LEVEL 4 EAST PLAN

POWER LEVEL 4 EAST PLAN

SIGNAL LEVEL 4 EAST DEMOLITION

SIGNAL LEVEL 4 EAST PLAN

SIGNAL RISER DIAGRAM

TELECOMMUNICATIONS DETAILS

TELECOMMUNICATIONS DETAILS

ENLARGED PLANS & DETAILS

SECURITY DEVICE DETAILS

ELECTRICAL SCHEDULES

ELECTRICAL SCHEDULES

ELECTRICAL SCHEDULES

BID ALTERNATES

DEPARTMENT OF VETERANS AFFAIRS

WILLIAM JENNINGS BRYAN DORN MEDICAL

CENTER

NOVUS ARCHITECTS, INC.

PO BOX 1005

MT. PLEASANT, SC 29465-1005

843-849-7407 (FAX) 843-849-6750

BRITT, PETERS & ASSOC.

1100 QUEENSBOROUGH BLVD., SUITE 202

MT. PLEASANT, SC 29464

843-284-0400 (FAX) 843-284-0401

LIFE SAFETY/FIRE PROTECTION CONSULTING

O'BRIEN & GERE

2170 ASHLEY PHOSPHATE RD., SUITE 504

CHARLESTON, SC 29406

843-553-6670 (FAX) 843-553-0755

NEWCOMB & BOYD CONSULTING ENGINEERING GROUP

303 PEACHTREE CENTER AVE., NE, SUITE 525

ATLANTA, GA 30303-1277

404-730-8432 (FAX) 404-730-8401

MECHANICAL / ELEC. / PLUMBING

STRUCTURAL

STRUCTURAL DETAILSS1

007200 General Conditions

1.67 Subcontracts and Work Coordination (VAAR 852.236-80) (April 1984)

The contractor shall be responsible to the government for acts and omissions of his/her own employees, and subcontractors and their employees. The contractor shall also be responsible for coordination of the work of the trades, subcontractors, and material suppliers. The contractor shall, in advance of the work, prepare coordination drawings showing the location of openings through slabs, the pipe sleeves and hanger inserts, as well as the location and elevation of the utility lines, including, but not limited to, converyor systems, pneumatic tubes, ducts, and conduits and pipes 50mm (2 inches) and larger in diameter. These drawings, including plans, elevations, and sections as appropriate shall clearly show the manner in which the utilities fit into the available space and how they relate to each other and to existing building elements. Drawings shall be of appropriate scale to satisfy the previously stated purposes, but not smaller than 9 mm (3/8 inch) scale.

Drawings may be composite (with distinctive colors for the various trades) or may be separate but fully coordinated drawings (such as sepias or photographic paper) reproducible of the same scale. Separate drawings shall depict identical building areas or sections and shall be capable of being overlaid in any combination. The submitted drawings for a given area of the project shall show the work of all trades which will be involved in that particular area. Six complete composite drawings or six complete sets of separate reproducible drawings shall be received by the government not less than 20 days prior to the scheduled start of work in the area illustrated by the drawings for the purpose of showing the contractor's planned method of installation. The objectives of such drawings are to promote carefully planned work sequence and proper trade coordination, in order to assure the expeditious solutions of problems and the installation of lines and equipment as contemplated by the contract documents while avoiding or minimizing additional costs to the contractor and to the government. In the event the contractor, in coordinating the various installations and in planning the method of installation, finds a conflict in the location or elevation of any of the utilities with themselves, with structural items or with other construction items, the contractor shall bring this conflict to the attention of the contracting officer immediately. In doing so, the contractor shall explain the proposed method of solving the problem or shall request instructions as to how to proceed if adjustments beyond those of usual trades coordination are necessary. Utilities installation work will not proceed in any area prior to the submission and completion of the government review of the coordinated drawings for that area, not in any area in which conflicts are disclosed by the coordination drawings until the conflicts have been corrected to the satisfaction of the contracting officer. It is the responsibility of the contractor to submit the required drawings in a timely manner consistent with the requirements to complete the work covered by the contract within the prescribed contract time.

DRAWING COORDINATION

BID ITEM 1, BASE BID: Contractor shall provide all tools, labor, materials, permits, licenses, and supervision for demolition, renovation, and new construction as indicated on drawings and specifications for project 544-322 located at the VA Medical Center in Columbia, SC. Note that drawings and specifications may reflect alternate bid items below. Where drawings and specifications reflect items included in bid alternate scope, omit those items for base bid. Work includes but is not limited to extensive interior demolition; general interior construction; alterations; mechanical and electrical work; utility systems; new finishes. Finishes include carpet; sheet vinyl flooring; solid surface walls and countertops; casework; wood doors and hardware; paint; multi color coatings; and gypsum and acoustical ceilings. General interior construction includes wall systems, interior storefront window systems, hollow metal door frames, and certain other items.

Note: All alternates below are in addition to the base bid and are to be priced separately. Alternates shall be selected by Owner in random order and in any combination required to provide best value within budget limitations.

BID ITEM 2, ALTERNATE 1: Perform all work as described in Bid Item 1. Provide complete LCD glazing system for sliding glass ICU doors as indicated in drawings in spaces 4C100A, 4C101, 4C102, 4C103, 4C104A, 4C105, 4C106, 4C107A, 4C108A, 4C109, 4C110, 4C112, 4C113, 4C114, 4C115, 4C116, 4C117A, 4C118, 4C119, 4C120, and 4C122A. Standard sliding glass ICU corridor doors in spaces 4C100, 4C104, 4C107, 4C108, 4C117, and 4C122A are not to receive LCD glazing. All sliding glass ICU doors are sole source items. See drawings. See electrical. See spec section 08 42 43 for vendor contact info. Note that sliding glass ICU doors in space 4C141 are to receive LCD glazing system as part of base bid.

BID ITEM 3, ALTERNATE 2: Perform all work as described in Bid Item 1. At windows indicated as type ‘A’ (see AS101 & AS601), provide aluminum windows with complete LCD glazing system in lieu of standard interior aluminum storefront windows. LCD-glazed windows are sole source items and are to be provided by the same manufacturer as sliding glass ICU doors. See drawings. See electrical. See spec section 08 42 43 for vendor contact info.

BID ITEM 4, ALTERNATE 3: Perform all work as described in Bid Item 1. At corridor patient observation desks described typically in drawings A6/AS110 and A4/AS111 (11 total), provide counter/floor mounted swinging chairs as indicated in drawings. Swinging chairs are sole source items. See drawings. See equipment schedule for vendor contact info.

BID ITEM 5, ALTERNATE 4: Perform all work as described in Bid Item 1. Provide complete video surveillance system as indicated in drawings. See electrical.

BID ITEM 6, ALTERNATE 5: Perform all work as described in Bid Item 1. Provide vinyl sheet flooring pattern as indicated on sheet AS701. See AS701 and finish schedule (section 09 06 00) for base bid description.

BID ITEM 7, ALTERNATE 6: Perform all work as described in Bid Item 1. At windows indicated as type ‘B’ (see AS101 & AS601), provide aluminum windows with complete LCD glazing system in lieu of standard interior aluminum storefront windows. LCD-glazed windows are sole source items and are to be provided by the same manufacturer as sliding glass ICU doors. See drawings. See electrical. See spec section 08 42 43 for vendor contact info.

BID SET

UP

NURSE MGR

4C163

STRETCHER / EQUIP.

STORAGE

4C111

CCU/MICU BED

4C109

PCU BED

4C103

PCU BED

4C101

CONF./STOR. ROOM

4C140

PCU/ISO BED

4C122A

PCU BED

4C120PCU BED

4C118

CCU/MICU ISO BED

4C117A

CCU/MICU BED

4C116

CCU/MICU BED

4C115

CCU/MICU BED

4C114

CCU/MICU BED

4C113

CCU/MICU BED

4C112

ON CALL

4C161

CLEAN UTILITY

4C164

LINEN

4C165 STAFF TOILET

4C156

SOILED UTILITY

4C160

BREAK ROOM

4C152

T.S.C.

4C121

NOURISHMENT

4C147

H.A.C.

4C148

MED GAS

4C159

CLEAN UTILITY

4C151

LINEN

4C144

STAFF TOILET

4C143

NURSE SUPER/CLIN.

PHARM

4C153

SOILED UTILITY

4C150

CORRIDOR

4C170

CORRIDOR

4C166

STAIR

PYXIS

PYXIS

FEC

MAXIMUM OVERALL DIAGONAL DIMENSION - 195'

DISTANCE BETWEEN EXISTING EXITS - 187' 8"

EXIT TRAVEL DISTANCE - 128' - 8"

EXIT TRAVEL DISTANCE - 129' -4"

EXIT TRAVEL DISTANCE - 97' - 10" EXIT TRAVEL DISTANCE - 143' - 4"

PT

STATION

CCU/MICU ISO BED

4C108A

CCU/MICU BED

4C106

ANTEROOM

4C107

BATH

4C103A

PCU BED

4C102

BATH

4C102A

BATH

4C101A

PCU/ISO BED

4C100A

BATH

4C118A

BATH

4C119A

BATH

4C120A

PCU BED

4C119

BATH

4C122B

XFEC

ANTEROOM

4C108

CCU/MICU ISO BED

4C107A

CCU/MICU BED

4C105

CCU/MICU ISO BED

4C104A

ANTE ROOM

4C104

CONFERENCE

4C145

MEDS RM

4C142

PROCEDURE ROOM

4C141

CONF. ROOM

4C139

ANTE ROOM

4C122

ANTE ROOM

4C100

STORAGE

4C157

MED RM

4C158

NURSE'S STATION

4C149

NURSE'S STATION

4C149

HVAC

4C131

FEC

FEC

FEC1'

/2

FIRE EXTINGUSHER CABINETFEC

FIRE EXIT SIGN

EXISTING FIRE EXTINGUSHER CABINETXFEC

1. REFER TO FIRE PROTECTION PLANS FOR ALL SPRINKLER AND ALARM COMPONENT

LOCATIONS NOT PROVIDED ON THIS SHEET.

2. FIRE EXTINGUISHERS PLACED PER NFPA 10 - MAXIMUM TRAVEL DISTANCE 75'-0"

3. SEE MECHANICAL FOR FIRE AND SMOKE DAMPER REQUIREMENTS

4.EXISTING STEEL COLUMNS PROTECTED W/ GYPSUM BLOCK/BOARD FIREPROOFING,

AND STEEL BEAMS & DECK PROTECTED W/ SPRAY APPLIED FIREPROOFING UNLESS

NOTED OTHERWISE. (GC RESPONSIBLE FOR MAINTAINING INTEGRITY OF ALL EXISTING

RATED ELEMENTS UNLESS OTHERWISE CALLED FOR IN THE CONTRACT DOCUMENTS,

AND COORDINATING APPROPRIATE INSPECTIONS BY VA SAFETY PERSONNEL W/

PROJECT ENGINEER)

5. GYPSUM BLOCK/BOARD & SPRAY APPLIED FIREPROOFING TO REMAIN IN PLACE AND

BE REPAIRED AS REQUIRED. FIRESTOP ALL NEW PENETRATIONS THROUGH EXISTING

FIRE RATED AND SMOKE RATED WALLS AND PARTITIONS TO MAINTAIN EXISTING FIRE

AND/OR SMOKE RATING OF EXISTING WALLS AND PARTITIONS. EXISTING FIRE RATED

AND SMOKE BARRIER WALLS REMAINING SHALL BE REPAIRED TO MAINTAIN REQUIRED

RATING.

SMOKE PARTITION (SEE FLOOR PLANS

FOR WALL AND DOOR DESIGNATIONS)

1 HR. FIRE AND SMOKE BARRIER PER UL #419

(SEE FLOOR PLANS FOR WALL AND DOOR

DESIGNATIONS)

1 HR. FIRE BARRIER PER UL #419 (SEE FLOOR

PLANS FOR WALL AND DOOR DESIGNATIONS)

EXISTING 1 HR. FIRE AND SMOKE BARRIER

EXISTING 2 HR. FIRE AND SMOKE BARRIER

APPLICABLE CODES (IN ORDER OF AUTHORITY)

1. VA FIRE PROTECTION DESIGN MANUAL

2. NFC CODES 2009

3. INTERNATIONAL CODES 2006

OCCUPANCY CLASSIFICATION

HEALTHCARE (NFPA 101, 6.1.5)

OCCUPANT LOAD

A. SLEEPING DEPARTMENTS: 13,983 SQ. FT./120=116 OCCUPANTS

B. EXISTING MECHANICAL ROOM: 1,460 SQ. FT./500=3 OCCUPANTS

C. 119 OCCUPANTS TOTAL

CONSTRUCTION CLASSIFICATION

TYPE I (332) - (NFPA 220)

FULLY SPRINKLERED

FIRE RESISTANCE REQUIREMENTS BY BUILDING COMPONENT

STRUCTURAL FRAME - 3 HOUR PROTECTED

BEARING WALLS - (INTERIOR & EXTERIOR) -1 HOUR PROTECTED

NONBEARING WALLS AND PARTITIONS - 0 HOUR

FLOOR CONSTRUCTION - 2 HOUR PROTECTED

(*VERIFY EXISTING CONSTRUCTION MEETS THESE REQUIREMENTS)

HAZARDOUS AREA SEPERATION - SMOKE PARTITION CONSTRUCTION (NFPA 101,

8.7.1.2)

MED GAS

SOILED LINEN

STORAGE > 100 SQ. FT.

EXIT LOCATION REQUIREMENTS

MAX. TRAVEL DISTANCE TO EXIT - 200 FT. (NFPA 101, 18.2.6)

MAX. COMMON PATH OF TRAVEL - 100 FT. (NFPA 101, 18.2.5.3)

DEAD END CORRIDOR - 30 FT. (NFPA 101, 18.2.5.2)

2 EXITS REQUIRED - REMOTELY LOCATED PER NFPA 101, 18.2.4.3

2 ACCESSIBLE MEANS OF EGRESS REQUIRED (NFPA 101, 7.5.4.1)

PROVIDED - 1 AREA OF REFUGE, AND 1 ACCESSIBLE EXIT (ADDITIONAL AREA OF

REFUGE PROVIDED IN STAIR #5 AS AN ALTERNATE TO RAMP CONSTRUCTION.) PER

NFPA 101, 18.2.2.10, AREAS OF REFUGE SHALL COMPLY W/ 7.2.12

1 2 43 5 6 7 8 9

D

EP

AR

TM

EN

T

O F

VE

TE

R

AN

S

AF

FA

IR

SDATE

PROJECT NO.

DRAWING NO.

FILE NAME

A:Projects/2006- 1111.06

PROJECT TITLE

BUILDING NUMBER CHECKED DRAWN

WILLIAM JENNINGS BRYAN DORN

V A MEDICAL CENTER

COLUMBIA, SOUTH CAROLINA

DRAWING TITLE

APPROVED : CHIEF, LOGISTICS

APPROVED : MED CTR SAFETY MANAGER

APPROVED : INFECTION CONTROL

APPROVED : CHIEF OF STAFF

APPROVED : ASSOC DIR FOR PATIENT/

NURSING SERVICES

APPROVED : DIR., INFRASTRUCTURE

APPROVED : ASSOCIATE DIRECTOR

1 2 43 5 6 7 8 9

A

B

C

D

E

F

DATEREVISIONS

APPROVED : MEDICAL CENTER DIRECTOR

FINAL CONTRACT DOCUMENTS

FULLY SPRINKLERED

APPROVED : STATION ENERGY MANAGER

05.21.10

544-322

GI002

RELOCATE ICU TO 4 EAST

TNS/PAF SNP

LIFE SAFETY PLAN

LIFE SAFETY GENERAL NOTES

CODE ANALYSIS

SCALE: 1/8" = 1'-0"GI002

LIFE SAFETY PLANA2

1. THIS WING, AS DEFINED BY EXTERIOR WALLS AND EXISTING TWO HR.

FIRE/SMOKE BARRIER, COMPRISES A SMOKE COMPARTMENT OF 15,680 SQ. FT.

2.EGRESS CAPACITY: (NFPA 101 TABLE 7.3.3.1)

A.SPRINKLERED OCCUPANCY: 0.2"X120 OCCUPANTS = 24". EXISTING

EXIT DOORS PROVIDE 127" CLEAR WIDTH. PROPOSED EXIT ACCESS

CORRIDOR WIDTH IS 8'.

3.TWO EXISTING EXITS ARE PROVIDED FROM THIS SMOKE COMPARTMENT. TWO

EXITS ARE REQUIRED BY NFPA 101 PARAGRAPH 18.2.4.3.

4. NFPA 101, PARAGRAPH 7.1.3.2.1 REQUIRES ENCLOSURE OF

INTERIOR VERTICAL EXITS BY TWO-HOUR FIRE BARRIERS WHERE SERVING FOUR

OR MORE FLOORS. EXISTING TWO-HOUR FIRE BARRIER AT STAIRWELL IS TO BE

MAINTAINED.

5.CORRIDOR WALLS TO BE CONSTRUCTED AS SMOKE PARTITIONS TO COMPLY

WITH NFPA 101, PARAGRAPH 18.3.6.2. SMOKE PARTITION WILL MEET THE

REQUIREMENTS OF NFPA 101-8.4 WITH THE EXCEPTION OF 8.4.2 (2) AND (3). SMOKE

PARTITIONS WILL TERMINATE AT THE FLOOR DECK ABOVE.

6.TO COMPLY WITH NFPA 101, PARAGRAPH 18.6.3.1, CORRIDOR DOORS IN SMOKE

PARTITIONS WILL PROVIDE EFFECTIVE RESISTANCE TO PASSAGE OF SMOKE AND

WILL BE EQUIPPED WITH POSITIVE LATCHING. CLOSERS ARE NOT REQUIRED FOR

SMOKE PARTITIONS. PROVIDE DOOR CLOSERS FOR ALL DOORS IN FIRE RATED

CONSTRUCTION.

7. NFPA 101 SECTION 18.3.3.2 - INTERIOR WALL AND CEILING FINISHES: EXIT

ENCLOSURES AND CORRIDORS - CLASS A; ROOMS AND ENCLOSED SPACES (LIMIT

4/ROOM) - CLASS A OR B. NFPA 101 SECTION 18.3.3.3 AND 10.2.7.1 & 10.2.7.2 - FLOOR

FINISHES: CLASS I OR II.

8. NEW SPRINKLER SYSTEM TO MEET REQUIREMENTS OF NFPA 13.

9. FLOORS ABOVE & BELOW SERVE AS A TWO-HOUR FIRE BARRIER. ALL

PENETRATIONS ARE TO BE PROTECTED AS REQUIRED TO MAINTAIN RATING. UL

LISTED DETAILS ARE REQUIRED FOR ALL PENETRATIONS. SEE MPE.

LIFE SAFETY WALL DESIGNATIONS

LIFE SAFETY LEGEND

PLAN NORTH

TRUE NORTH

CODE NOTES

AF.F. ABOVE FINISH FLOOR

ALUM. ALUMUNIMUM

ANOD. ANODIZED

ARCH. ARCHITECTURAL/ARCHITECT

@ AT

BRG. BEARING

BOT. BOTTOM

BLDG. BUILDING

(C) CAULK

CAB. CABINET

C.F.C.I. CONTRACTOR FURNISHED, CONTRACTOR INSTALLED

C.F.O.I. CONTRACTOR FURNISHED, OWNER INSTALLED

CLG. CEILING

CPT. CARPET

CTR. CENTER

CLOS. CLOSET

COL. COLUMN

CONC. CONCRETE

C.J. CONTROL JOINT

DTL. DETAIL

DIA. DIAMETER

DIM. DIMENSION

DN. DOWN

DWG. DRAWING

EA. EACH

ELEC. ELECTRIC/ELECTRICAL

E.W.C. ELECTRIC WATER COOLER

ELEV. ELEVATION-GRADEORBLDG.

E.J. EXPANSION JOINT

EQ. EQUAL

EQUIP. EQUIPMENT

E.F. EXHAUST FAN

EXIST.,(E) EXISTING

EXT. EXTERIOR

FT. FEET

FIN. FINISH

F.E. (ON WALL BRACKET) FIRE EXTINGUISHER

F.E.C. (IN WALL CABINET) FIRE EXTINGUISHER

FLR. FLOOR

F.D. FLOOR DRAIN

GALV. GALVANIZED

GA. GAUGE

GYP.BD. GYPSUM BOARD

HC HANDICAP ACCESSIBLE

HDWR. HARDWARE

HT. HEIGHT

H.M. HOLLOW METAL

HORIZ. HORIZONTAL

INSUL. INSULATION

INT. INTERIOR

JAN. JANITOR

JT. JOINT

LAM. LAMINATE

LAV. LAVATORY

MFR. MANUFACTURER

M.O. MASONRY OPENING

MATL. MATERIAL

MAX. MAXIMUM

MECH. MECHANICAL

MTL. METAL MIN. MINIMUM

(N) NEW

N.I.C. NOT IN CONTRACT

N.T.S. NOT TO SCALE

O.C. ON CENTER

O.F.C.I. OWNER FURNISHED, CONTRACTOR INSTALLED

O.F.O.I. OWNER FURNISHED, OWNER INSTALLED

OPNG. OPENING

O.H. OPPOSITE HAND

O.R.D. OVER FLOW ROOF DRAIN

(P) PAINT

PLYWD. PLYWOOD

PR. PAIR

PREF. PRE FINISHED

PREFAB. PREFABRICATED

RADIUS RAD., R.

RE: REFERENCE

REINF. REINFORCE

REQ'D. REQUIRED

(LEADER) R.D. ROOF DRAIN

(L) R.O. ROUGH OPENING

SHT. SHEET

SIM. SIMILAR

SPECS. SPECIFICATIONS

S.S. STAINLESS STEEL

STD. STANDARD

STL. STEEL

STRUCT. STRUCTURAL

TEL. TELEPHONE

TR. TREATED

TYP. TYPICAL

U.N.O. UNLESS NOTED OTHERWISE

(V) VERIFY

V.C.T. VINYL COMPOSITION TILE

VERT. VERTICAL

V.T.R. VENT THROUGH ROOF

W.C. WATER CLOSET

WD. WOOD

1/8" = 1'-0"A102 A401

12"

18"

DETAIL IS REFERENCED

SHEET NO. WHERE

View Name

DETAIL W/ REFERENCE

PLAN OR SECTION

DETAIL NUMBER

DETAIL IS DRAWN

SHEET NO. WHERE

HARDWARE SET

DOOR SIZE

DOOR TYPE

JAMB TYPE

1 5 H T

ROOM NUMBER

ROOM NAME

AROUND AREA DETAILED

MEDIUM DASHED LINE

SHEET NO. WHERE

DETAIL NUMBER

SHEET NO. WHERE

DETAIL NUMBER

SECTION IS DRAWN

DETAIL IS DRAWN

& NUMBER

ROOM NAME

COLUMN GRID LINE

DETAIL

PLAN OR SECTION

SECTION DETAIL

BUILDING OR WALL

SECTION IS DRAWN

SHEET NO. WHERE

ELEVATION IS DRAWN

SHEET NO. WHERE

ELEVATION IS DRAWN

SHEET NO. WHERE

DETAIL NUMBER

DETAIL NUMBER

DOOR MODIFICATION

TO MEET ADA REQUIREMENTS)

WINDOW TYPE IS DRAWN

SEE DOOR SCHEDULE

DETAIL NUMBER

DETAIL

OR WALL

SECTION DETAIL

DETAIL

DOOR NUMBER

WINDOW TYPE

STOREFRONT OR

EXTERIOR ELEVATION

INTERIOR ELEVATION

WALL PARTITION TYPE

TYPE

WALL PARTITION

DETAIL NUMBERPARTIAL BUILDING

(PROVIDE MIN. CLEARANCES SHOWN

A

LOBBY

AS101

A1

AS101

A1

AS101

A1

AS101

A1

AS101

A1

X

1 2 43 5 6 7 8 9

D

EP

AR

TM

EN

T

O F

VE

TE

R

AN

S

AF

FA

IR

SDATE

PROJECT NO.

DRAWING NO.

FILE NAME

A:Projects/2006- 1111.06

PROJECT TITLE

BUILDING NUMBER CHECKED DRAWN

WILLIAM JENNINGS BRYAN DORN

V A MEDICAL CENTER

COLUMBIA, SOUTH CAROLINA

DRAWING TITLE

APPROVED : CHIEF, LOGISTICS

APPROVED : MED CTR SAFETY MANAGER

APPROVED : INFECTION CONTROL

APPROVED : CHIEF OF STAFF

APPROVED : ASSOC DIR FOR PATIENT/

NURSING SERVICES

APPROVED : DIR., INFRASTRUCTURE

APPROVED : ASSOCIATE DIRECTOR

1 2 43 5 6 7 8 9

A

B

C

D

E

F

DATEREVISIONS

APPROVED : MEDICAL CENTER DIRECTOR

FINAL CONTRACT DOCUMENTS

FULLY SPRINKLERED

APPROVED : STATION ENERGY MANAGER

05.21.10

544-322

AS001

RELOCATE ICU TO 4 EAST

TNS/PAF SNP

ABBREVIATIONS & SYMBOLS

SYMBOL LEGEND ABBREVIATIONS

WALL TYPES

TYPE

MARK

FIRE

BARRIER

RATING DESCRIPTION DETAIL

1 EXISTING INTERIOR PARTITION. PATCH

AS REQ'D FOR CONTINUOUS GYP BRD

FINISH AND ALIGN W/ NEW ADJACENT

CONSTRUCTION. NEW & EXISTING GYP

BRD TO BE PAINTED (P-1). SEE FINISH

SCHEDULE

1.1 EXISTING EXTERIOR WALL. PATCH AS

REQ'D. AT REMOVED INTERIOR

PARTITION LOCATIONS FOR

CONTINUOUS GYP BRD FINISH. NEW &

EXISTING GYP BRD TO BE PAINTED

(P-1). SEE FINISH SCHEDULE. SEE

FINISH PLAN FOR NEW RIGID VINYL

SHEET LOCATIONS.

2 1 HR FIRE

/ SMOKE

EXISTING 1-HOUR FIRE/SMOKE

BARRIER. NEW AND EXISTING

PENETRATIONS TO BE PROPERLY

SEALED AND PROTECTED TO

MAINTAIN RATING. PATCH AS REQ'D TO

MAINTAIN RATING AT REMOVED WALL

LOCATIONS. NEW & EXISTING GYP BRD

TO BE PAINTED ON

CORRIDOR/PATIENT ROOM/EQUIP

STORAGE SIDE (P-1). SEE FINISH

SCHEDULE. SEE FINISH PLAN FOR

RIGID VINYL SHEET LOCATIONS.

3 2 HR FIRE

/ SMOKE

EXISTING 2-HOUR FIRE/SMOKE

BARRIER. NEW AND EXISTING

PENETRATIONS TO BE PROPERLY

SEALED AND PROTECTED TO

MAINTAIN RATING.

4 EXISTING WALL TO BE UPGRADED TO

SMOKE PARTITION.

B3/AS301

SIMILAR

5 NEW WALL, 3 5/8" METAL STUDS, 3-1/2"

SOUND ATTENUATION BLANKETS, W/

5/8" GYP BRD EACH SIDE UNLESS

SHOWN OTHERWISE.

6 NEW SMOKE PARTITION W/ 3-1/2"

SOUND ATTENUATION BLANKETS.

PROVIDE 6" METAL STUDS AT

PLUMBING WALLS.

7 1 HR

UL# 419

NEW 1-HOUR FIRE BARRIER W/ 3-1/2"

SOUND ATTENUATION BLANKETS.

PROVIDE 6" METAL STUDS AT

PLUMBING WALLS

7.1 1 HR FIRE

/ SMOKE

UL#419

NEW 1-HOUR FIRE/SMOKE BARRIER W/

3-1/2" SOUND ATTENUATION

BLANKETS. PROVIDE 6" METAL STUDS

AT PLUMBING WALLS

8 NEW CHASE W/ 3-1/2" SOUND

ATTENUATION BLANKETS. CHASE TO

ACCOMODATE CARRIERS AT WALL

MOUNTED LAVS, SINKS, & TOILETS,

ETC. CONSTRUCT AS SMOKE

PARTITION WHERE REQ'D.

9 NEW PLUMBING WALL, W/ 3-1/2" SOUND

ATTENUATION BLANKETS. PROVIDE 6"

METAL STUDS W/ 5/8" GYP BD EACH

SIDE.WALL TO ACCOMODATE

CARRIERS AT WALL MOUNTED LAVS.

9.1 NEW PLUMBING WALL, W/ 3-1/2" SOUND

ATTENUATION BLANKETS. PROVIDE 8"

WIDE METAL STUD FRAMING W/ 5/8"

GYP BD EACH SIDE.WALL TO

ACCOMODATE CARRIERS AT WALL

MOUNTED LAVS.

B5/AS301

SIMILAR

WALL LEGEND

B3/AS301

B1/AS301

B1/AS301

SIMILAR

B7/AS301

B5/AS301

PT

STATION

A

A

B

B

F

F

G

G

H

H

I

I

J

J

K

K

C

C

1 1

2 2

3 3

4 4 8 8 8 8 8 8 8 8 8 8

88888888

5 5 10 10 10 10 10 10 10 10 10 10 10

555555

3 3

33 3 3

3 3

3 3 3

3 3

3 3

3 3

3 3

5 10

10 10 10

10 10 10 10 10 10

10 10

111111

10 10

10 10

10 10

10 10 10

9FEC

FEC

11 11 11

D

D

FEC

15 17

WALL TO REMAIN

WALL TO REMOVE

FEC EXISTING FIRE ALARM CABINET TO

REMAIN UNLESS NOTED OTHERWISE

EXISTING PNEUMATIC TUBE STATION TO BE RELOCATED. PROTECT DURING

CONSTRUCTION. VA TUBE SYSTEM VENDOR IS TO BE ENGAGED FOR REQUIRED

WORK & INCLUDED IN THE GC'S CONSTRUCTION CONTRACT. CONTACT VENDOR

FOR EXACT SCOPE OF WORK (PEVCO SYSTEMS 800-738-2699). SEE ELECTRICAL.

TUBE SYSTEM PIPING TO BE CONFIGURED AS REQUIRED FOR RELOCATION.

SEE MPE FOR DEMOLITION IN EXISTING MECH. ROOM

REMOVE FULL HEIGHT MTL. LOCKERS COMPLETE.

EXISTING BUILDING EXPANSION JOINT. METAL COVER PLATES &

FIRESTOP MATERIAL TO REMAIN. PROTECT DURING CONSTRUCTION.

REMOVE FULL HEIGHT MED GAS / POWER COLUMN AND WALL MOUNTED OVERBED

LIGHT FIXTURES COMPLETE. SEE MPE.

REMOVE ACCORDION PARTITION AND TRACK COMPLETE.

EXISTING STAINLESS STEEL WINDOW SILL TRIM TO BE MODIFIED AS REQUIRED TO

ACCOMODATE REDUCED WALL WIDTH.

REMOVE FLOOR MOUNTED HVAC EQUIPMENT. SEE MPE.

REMOVE FIRE EXTINGUISHER CABINET COMPLETE.

EXCEPT FOR GYP. BOARD FINISH AT WALLS TO REMAIN, ALL FINISHES TO BE

REMOVED. EXISTING FINISHES IN THIS SPACE INCLUDE PAINTED GYP. BOARD,

RUBBER WALL BASE, & VCT FLOOR.

EXCEPT FOR GYP. BOARD FINISH AT WALLS TO REMAIN, ALL FINISHES TO BE

REMOVED. EXISTING FINISHES IN THIS SPACE INCLUDE PAINTED GYP. BOARD, 4x4 CT WAINSCOT, AND 1x1 CT FLOOR.

12 EXCEPT FOR GYP. BOARD FINISH AT WALLS TO REMAIN, ALL CORRIDOR

FINISHES TO BE REMOVED. CORRIDOR FINISHES INCLUDE PAINTED GYP

BOARD, 4x4 CT WAINSCOT, RUBBER WALL BASE.

13 REMOVE WALL MOUNTED FAN UNIT.

14 EXISTING FURRED WALL TO BE REMOVED.

16 EXISTING 20 MIN. DOUBLE EGRESS DOORS TO BE REPLACED W/ 1-

HOUR FIRE DOORS FOR DURATION OF CONSTRUCTION. NEW FIRE

RATED AUTOMATIC DOUBLE EGRESS DOORS TO BE PROVIDED AS

PART OF WORK. SEE AS101.

HOSE REEL IS TO BE PROVIDED BY GC AT OR NEAR THIS

LOCATION WITH ALL REQUIRED CONNECTIONS AND IS TO BE

MAINTAINED THROUGHOUT DEMOLITION PHASE.

PROVIDE TWO 6" DIA. PENETRATIONS THROUGH SLAB FOR RELOCATED

PNEUMATIC TUBE RISERS. COORDINATE EXACT LOCATIONS W/

PNEUMATIC TUBE SYSTEM VENDOR (PEVCO SYSTEMS).

18 FOR DURATION OF COSTRUCTION, SIGN TO BE PROVIDED ON OUTSIDE

OF DOORS INDICATING "NO EXIT". EXISTING EXIT SIGNS &

DIRECTIONAL ARROWS POINTING TO AREA OF WORK ARE TO BE

COVERED.

1 2 43 5 6 7 8 9

D

EP

AR

TM

EN

T

O F

VE

TE

R

AN

S

AF

FA

IR

SDATE

PROJECT NO.

DRAWING NO.

FILE NAME

A:Projects/2006- 1111.06

PROJECT TITLE

BUILDING NUMBER CHECKED DRAWN

WILLIAM JENNINGS BRYAN DORN

V A MEDICAL CENTER

COLUMBIA, SOUTH CAROLINA

DRAWING TITLE

APPROVED : CHIEF, LOGISTICS

APPROVED : MED CTR SAFETY MANAGER

APPROVED : INFECTION CONTROL

APPROVED : CHIEF OF STAFF

APPROVED : ASSOC DIR FOR PATIENT/

NURSING SERVICES

APPROVED : DIR., INFRASTRUCTURE

APPROVED : ASSOCIATE DIRECTOR

1 2 43 5 6 7 8 9

A

B

C

D

E

F

DATEREVISIONS

APPROVED : MEDICAL CENTER DIRECTOR

FINAL CONTRACT DOCUMENTS

FULLY SPRINKLERED

APPROVED : STATION ENERGY MANAGER

05.21.10

544-322

AD101

RELOCATE ICU TO 4 EAST

TNS/PAF SNP

DEMOLITION FLOOR PLAN

SCALE: 1/8" = 1'-0"AD101

FLOOR PLAN - DEMOLITIONA2

LEGEND GENERAL DEMOLITION NOTES

1. THIS PLAN REPRESENTS EXISTING CONDITIONS. IT IS INTENDED FOR REFERENCE

ONLY. THE PLAN IS NOT INTENDED AS A DETAILED DESCRIPTION OF ALL OBJECTS

REQUIRED TO BE REMOVED IN ORDER TO CONSTRUCT THE WORK.

2. DEMOLISH EXISTING WALLS SHOWN DASHED ON THE PLAN. INCLUDE SHORING

AND/OR STRUCTURAL IMPLENTS AS REQUIRED TO PROVIDE A SOUND PERMANENT

STRUCTURE PER APLICABLE CODES.

3. ALL EXISTING PLUMBING FIXTURES TO BE REMOVED COMPLETE. SEE MPE. ALL

VANITY SINKS, COUNTERTOPS / CASEWORK, AND ACCESORIES (INCLUDING BUT NOT

LIMITED TO MIRRORS, PT DISPENSER, SOAP DISPENSERS) TO BE REMOVED COMPLETE.

ALL SHOWERS TO BE REMOVED COMPLETE (INCLUDING BUT NOT LIMITED TO PLUMBING

ACCESSORIES, TILE ENCLOSURES). SHOWER CURBS TO BE REMOVED FLOORS ARE TO

BE REMOVED TO LEVEL OF ADJACENT FLOOR SLAB.

4. REMOVE ALL MECHANICAL, PLUMBING, AND ELECTRICAL NOT NOTED FOR REUSE AND

CAP. SEE MPE DEMOLITION PLANS.

5. ALL COLUMNS, BEAMS, BRACING AND STRUCTURAL ELEMENTS TO REMAIN UNLESS

OTHERWISE NOTED.

6. EXISTING THREE-HOUR STRUCTURAL FIREPROOFING TO REMAIN. REPAIR AS

REQUIRED TO MAINTAIN RATING. EXISTING STEEL COLUMNS ARE PROTECTED W/

GYPSUM BLOCK/BOARD. EXISTING STEEL BEAMS & DECK ARE PROTECTED W/ SPRAY

APPLIED FIREPROOFING.

7. UNLESS OTHERWISE NOTED, GYP. BOARD WALL FINISH, WINDOWS, & WINDOW SILLS

AT EXTERIOR WALLS TO REMAIN.

8. ABATEMENT OF ASBESTOS-CONTAINING TILE AND MASTIC THROUGHOUT THE AREA

TO BE CARRIED OUT BY THE VA. GC TO PERFORM ALL OTHER DEMOLITION AS INDICATED

AND COORDINATE W/ VA PROJECT MANAGER TO ALLOW TIME AND ACCESS FOR

ASBESTOS ABATEMENT.

9. COORDINATE W/ VA PROJECT ENGINEER REGARDING PHASING OF DEMOLITION

AFFECTING OTHER FLOORS / BUILDING AREAS. ADJACENT FLOORS & BUILDING AREAS,

WILL BE OCCUPIED AND ARE TO REMAIN OPERATIONAL DURING CONSTRUCTION.

10. AT COMPLETION OF DEMOLITION, COORDINATE WITH VA PROJECT ENGINEER FOR

INSPECTION AND REVIEW OF EXISTING CONDITIONS (INCLUDING FIRE-RATED

PENETRATIONS) AND MPE ITEMS TO REMAIN.

11. AT WALLS TO REMAIN INCLUDING EXTERIOR WALLS, REMOVE ANY VINYL WALL

COVERING, WALL PAPER TRIM, WALL BASE, CHAIR RAIL MOULDING, ETC. ONLY GYP.

BOARD FINISH TO REMAIN.

12. DUST IS TO BE CONTAINED WITHIN THE WORK AREA. COORDINATE W/ MECHANICAL

PHASING TO KEEP DUST OUT OF DUCTWORK & MINIMIZE THE SPREAD OF

CONSTRUCTION DUST.

13. SEE AD102 FOR CEILING DEMOLITION REQUIREMENTS.

14. PROTECT ANY FINISHES TO REMAIN DURING CONSTRUCTION.

15. EXISTING 2-HOUR FLOOR & CEILING SEPARATIONS TO REMAIN. REPAIR AS REQ'D TO

MAINTAIN RATING LEAVING NO OPEN PENETRATIONS AT CLOSE OF DAILY ACTIVITIES. USE

TEMPORARY SYSTEM (2-HOUR RATED) WHERE PENETRATIONS ARE TO BE ACCESSED

LATER FOR ONGOING WORK.

KEY NOTES

PLAN NORTH

A

B

B

F

F

G

G

H

H

I

I

J

J

K

K

C

C

TV

TV

TVTV

TV

4 4 4

D

D

TV

2x2 LIGHT FIXTURE TO BE REMOVED. SEE MPE.

2x4 LIGHT FIXTURE TO BE REMOVED. SEE MPE.

1x4 LIGHT FIXTURE TO BE REMOVED. SEE MPE.

SUPPLY GRILL TO BE REMOVED. SEE MPE.

RETURN GRILL TO BE REMOVED. SEE MPE.

SPEAKER TO BE REMOVED. SEE MPE.

EXIT SIGN TO BE REMOVED. SEE MPE.

CEILING MOUNTED TV & BRACKET TO BE REMOVED. SEE MPE.

GYP BOARD CEILING & FRAMING ASSOCIATED TO BE REMOVED

CURTAIN TRACK TO BE REMOVED

2x2 ACOUSTICAL CEILING TO BE REMOVED

METAL ACCESS PANEL TO BE REMOVED.

ITEM TO REMAIN

ITEM TO BE REMOVED

1x1 SUPPLY GRILL TO BE REMOVED. SEE MPE.

1x1 RETURN GRILL TO BE REMOVED. SEE MPE.

REMOVE HEAVY DUTY STAINLESS STEEL LIFT RAIL COMPLETE.

NO DEMOLITION THIS AREA.

NO CEILING IN THIS SPACE. SEE MPE FOR DEMOLITION IN THIS AREA.

REMOVE ACCORDION PARTITION, TRACK, AND SOFFIT COMPLETE.

REMOVE CUBICLE CURTAIN & TRACK SYSTEM COMPLETE.5

1 2 43 5 6 7 8 9

D

EP

AR

TM

EN

T

O F

VE

TE

R

AN

S

AF

FA

IR

SDATE

PROJECT NO.

DRAWING NO.

FILE NAME

A:Projects/2006- 1111.06

PROJECT TITLE

BUILDING NUMBER CHECKED DRAWN

WILLIAM JENNINGS BRYAN DORN

V A MEDICAL CENTER

COLUMBIA, SOUTH CAROLINA

DRAWING TITLE

APPROVED : CHIEF, LOGISTICS

APPROVED : MED CTR SAFETY MANAGER

APPROVED : INFECTION CONTROL

APPROVED : CHIEF OF STAFF

APPROVED : ASSOC DIR FOR PATIENT/

NURSING SERVICES

APPROVED : DIR., INFRASTRUCTURE

APPROVED : ASSOCIATE DIRECTOR

1 2 43 5 6 7 8 9

A

B

C

D

E

F

DATEREVISIONS

APPROVED : MEDICAL CENTER DIRECTOR

FINAL CONTRACT DOCUMENTS

FULLY SPRINKLERED

APPROVED : STATION ENERGY MANAGER

05.21.10

544-322

AD102

RELOCATE ICU TO 4 EAST

TNS/PAF SNP

DEMOLITION REF. CEILING PLAN

SCALE: 1/8" = 1'-0"AD102

DEMO REFLECTED CEILING PLANA2

DEMOLITION KEY NOTES

GENERAL DEMOLITION NOTES

LEGEND

1. THIS PLAN REPRESENTS EXISTING CONDITIONS. IT IS INTENDED FOR REFERENCE ONLY.

THE PLAN IS NOT INTENDED AS A DETAILED DESCRIPTION OF ALL WORK.

2. DUST IS TO BE CONTAINED WITHIN THE WORK AREA. COORDINATE WITH MECHANICAL

PHASING TO KEEP DUST OUT OF DUCTWORK AND MINIMIZE THE SPREAD OF

CONSTRUCTION DUST.

3. REMOVE ALL MECHANICAL, PLUMBING, AND ELECTRICAL NOT NOTED FOR REUSE AND

CAP. SEE MPE DEMOLITION PLANS.

4. ALL COLUMNS, BEAMS, BRACING, AND STRUCTURAL ELEMENTS TO REMAIN UNLESS

OTHERWISE NOTED.

5. EXISTING 3-HOUR STRUCTURAL FIREPROOFING TO REMAIN. REPAIR AS REQUIRED TO

MAINTAIN RATING. (SEE SPECIFICATIONS FOR THIRD PARTY TESTING.) EXISTING STEEL

COLUMNS ARE PROTECTED W/ GYPSUM BLOCK/BOARD. EXISTING STEEL BEAMS & DECK

ARE PROTECTED W/ SPRAY APPLIED FIREPROOFING.

6. COORDINATE WITH VA PROJECT ENGINEER REGARDING PHASING OF DEMOLITION

AFFECTING OTHER FLOORS / BUILDING AREAS. ADJACENT FLOORS & BUILDING AREAS

WILL BE OCCUPIED AND ARE TO REMAIN OPERATIONAL DURING CONSTRUCTION.

7. AT COMPLETION OF DEMOLITION, COORDINATE WITH VA PROJECT ENGINEER FOR

INSPECTION AND REVIEW OF EXISTING CONDITIONS & MPE ITEMS TO REMAIN.

8. UNLESS NOTED OTHERWISE, ALL EXISTING CEILING SYSTEMS IN AREA OF WORK ARE TO

BE REMOVED COMPLETE.

9. UNLESS NOTED OTHERWISE, ALL CEILING MOUNTED FIXTURES AND EQUIPMENT IN AREA

OF WORK TO BE REMOVED COMPLETE.

10. SEE MPE FOR DEMOLITION OF EXISTING FIRE ALARM AND SPRINKLER SYSTEM

COMPONENTS.

11. EXISTING 2-HOUR FLOOR & CEILING SEPARATIONS TO REMAIN. REPAIR AS REQ'D TO

MAINTAIN RATING LEAVING NO OPEN PENETRATIONS AT CLOSE OF DAILY ACTIVITIES. USE

TEMPORARY SYSTEM (2-HOUR RATED) WHERE PENETRATIONS ARE TO ACCESSED LATER

FOR ONGOING WORK.

PLAN NORTH

NURSE MGR

4C163

STRETCHER / EQUIP.

STORAGE

4C111

CCU/MICU BED

4C109

CCU/MICU ISO BED

4C107A CCU/MICU BED

4C106

PCU BED

4C103

PCU BED

4C101

CONF./STOR. ROOM

4C140

PCU/ISO BED

4C122A

PCU BED

4C120

PCU BED

4C118

CCU/MICU ISO BED

4C117A

CCU/MICU BED

4C116

CCU/MICU BED

4C115

CCU/MICU BED

4C114

CCU/MICU BED

4C113

CCU/MICU BED

4C112

ON CALL

4C161

CLEAN UTILITY

4C164 LINEN

4C165

STAFF TOILET

4C156

SOILED UTILITY

4C160

BREAK ROOM

4C152

T.S.C.

4C121 NOURISHMENT

4C147

H.A.C.

4C148

CONFERENCE

4C145

MED GAS

4C159

CLEAN UTILITY

4C151

LINEN

4C144

STAFF TOILET

4C143

NURSE SUPER/CLIN.

PHARM

4C153

SOILED UTILITY

4C150

CORRIDOR

4C170

CORRIDOR

4C166

STAIR

BATH

4C102A

BATH

4C103A

ANTEROOM

4C107

75 LOCKERS

BATH

4C101A

PCU/ISO BED

4C100A

PCU BED

4C102

PCU BED

4C119

A

A

B

B

F

F

G

G

H

H

I

I

J

J

K

K

C

C

1 1

2 2

3 3

4 4

CCU/MICU ISO BED

4C108A

BATH

4C118A

BATH

4C119A

BATH

4C120A

BATH

4C122B

G 2 5

E 2 5

G 2 5

G 2 5

C 2 3

F3/4

F 2 5G

2 5

E 2 5

G 2 5

G 2 5

A 1 1

A 3 6

G 2 5

G 2 5

G 2 5

BIOMED

4C155

27222

2 2 27

HVAC

4C131

13.1

14 14

169169169

G 2 5

CCU/MICU BED

4C105

CCU/MICU ISO BED

4C104A

D

D

3 3

3 3 3 3

3 3 3

PROCEDURE ROOM

4C141

CONF. ROOM

4C139

MEDS RM

4C142

BATH

4C100B

ANTE ROOM

4C100

ANTE ROOM

4C122

NURSE'S STATION

4C149

NURSE'S STATION

4C149

STORAGE

4C157

MED RM

4C158

ANTE ROOM

4C117

ANTEROOM

4C108

A 1 1

A 1 1

A 3 6

A 1 1

A 1 1

A 1 1

A 3 6

A 1 1

A 1 1

A 1 1

A 1 1

A 3 6

A 1 1

A 1 1

A 1 1

A 1 1

A 1 1

A 3 6

A 1 1

A 1 1

A 3 6

A 1 1

A 1 1

169 169 169 169

169 169 169

169 169

G 2 5

G 2 5

G 2 5

G 2 5 G

2 5 14

G 2 5

E 2 5

E 2 5

E 2 5

G 2 5

XFEC

E 2 5

E 2 5

A 1 1

A 1 1

169.1

169.1

A

B

A

B B

A

B B

B B

A

B B

A

B

A

B B

B B

A

B B

A

B B

A A

B B

G 2 5C

2 3

F3/4 F3/4

G 2 5

F3/4

F3/4

G 2 5

ANTE ROOM

4C104

CORRIDOR

4C171

CORRIDOR

4C172

CORRIDOR

4C167

CORRIDOR

4C169

CORRIDOR

4C168

39.1

G 2 5

FEC

FECG

2 5

A 1 1

FEC

CCU/MICU BED

4C110

D 2 5

F3/4

F3/4

F3/4

131313

13 13 13

16161616

16 16 16 16

A 1 1

B

H 2 7

F1-1/2

16161616161616

161616161616 14 14 14 14 14 14

14 14 14 14

14 1414 14 14 14 14

14 14 14 14

F3/4

1. PATCH AND REPAIR ANY AREA AFFECTED BY DEMOLITION. MATCH ADJOINING FINISHES

TO REMAIN. PREP AS REQUIRED TO RECEIVE NEW FINISHES.

2. PROVIDE BLOCKING AS REQUIRED FOR WALL MOUNTED CASEWORK, EQUIPMENT,

HANDRAILS, TOILET ACCESSORIES. SEE MPE. SEE ENLARGED EQUIPMENT PLANS. SEE

FINISH PLANS. SEE E3/AS503 FOR TYP. BLOCKING DETAIL.

3. EXISTING FIRE BARRIERS TO BE REPAIRED AS REQUIRED TO MAINTAIN RATING.

4. NEW AND EXISTING PENETRATIONS THROUGH NEW AND EXISTING FIRE AND SMOKE

BARRIERS TO BE PROPERLY SEALED AND PROTECTED AS REQUIRED TO MAINTAIN

RATINGS. UL LISTED DETAILS ARE REQUIRED AT ALL PENETRATIONS. SEE MP&E.

5. EXISTING THREE-HOUR STRUCTURAL FIRE PROOFING TO REMAIN IN PLACE. REPAIR AS

REQUIRED TO MAINTAIN CONTINUITY AND FIRE RATING. SEE SPECIFICATION FOR THIRD

PARTY TESTING. EXISTING STEEL COLUMNS ARE PROTECTED W/ GYPSUM BLOCK/BOARD.

EXISTING STEEL BEAMS & DECK ARE PROTECTED W/ SPRAY APPLIED FIREPROOFING.

6. VERIFY FIRE RATINGS INDICATED AS EXISTING. IMMEDIATELY NOTIFY VA PROJECT

ENGINEER OF ANY DISCREPANCIES.

7. PATCH FLOOR / CEILING SLABS AS REQUIRED FOR FIRE & SMOKE RESISTANCE AT

REMOVED / ABANDONED CHASES AND FLOOR PENETRATIONS. SEE MPE. SEE

STRUCTURAL SHEET S1 FOR PATCH DETAILS.

8. PROVIDE NEW FLOOR / CEILING SLAB PENETRATIONS AS REQUIRED FOR MPE. SEE

MPE. SEE STRUCTURAL FOR PENETRATION DETAILS WHERE REQUIRED.

9. PROVIDE FLOOR LEVELING AS REQUIRED AT REMOVED FLOOR TILE LOCATIONS.

10. SEE DIMENSION PLAN AND ENLARGED PLANS FOR DIMENSIONS. SEE AS601 FOR

DOOR & WINDOW SIZES.

11. ANY EXISTING WALL TO REMAIN SHALL BE UPGRADED FOR FIRE & SMOKE

REQUIREMENTS WHERE INDICATED.

12. CARRIERS TO BE PROVIDED IN WALLS AT ALL WALL MOUNTED LAVS, SINKS, &

TOILETS. SEE PLUMBING. VERIFY REQUIRED CLEARENCES AND REPORT ANY

DISCREPENCES TO AREA.

13. FLOOR ABOVE & BELOW IS A TWO-HOUR FIRE BARRIER. NEW & EXISTING

PENETRATIONS TO BE PROPERLY SEALED & PROTECTED AS REQUIRED TO MAINTAIN

RATING. UL LISTED DETAILS ARE REQUIRED FOR ALL PENETRATIONS. SEE MPE.

14. AT EXISTING COLUMNS, MAINTAIN EXISTING FIREPROOFING. PROVIDE MINIMUM

ADDITIOINAL FURRING AND GYP. BD. FINISH AS REQ'D TO ALIGN W/ NEW CONSTRUCTION.

15. SEE AS601 FOR DOOR HARDWARE SCHEDULE.

PROVIDE FLOOR LEVELING AS REQUIRED AT EXISTING SLAB DEPRESSION /

REMOVED TILE LOCATION.

SEE FINISH PLAN FOR SHOWER FLOOR FINISH AND THRESHOLD. BUILD UP

EXISTING FLOOR SLAB SUCH THAT SHOWER FLOOR SLOPES TO DRAIN AT 1/4"

PER FT. MIN. SEE SHOWER FLOOR DETAIL B8/AS503.

COLUMN HEADWALL UNIT AT THIS LOCATION. SEE B8/AS202 & ENLARGED PLANS

FOR UNIT CONFIGURATIONS.

REPLACE EXISTING GLAZING W/ INSULATING SPANDREL UNITS. PACK

VOID BETWEEN WINDOWS & NEW WALL W/ BATT INSULATION.

EXISTING EXPANSION JOINT. ADUJST / REINSTALL METAL COVER PLATE AS

REQUIRED TO ACCOMODATE NEW FINISHES.

MODIFY EXISTING STAINLESS STEEL WINDOW SILL TRIM AS REQUIRED TO

ACCOMODATE REDUCED WALL WIDTH.

CARD READER TO BE INSTALLED AT DOOR. SEE ELECTRICAL.

9 EXTEND EXISTING GYP BOARD FINISH ON BOTHS SIDES OF WALLS IN

TELECOMUNICATIONS (T.S.C.) TO UNDERSIDE OF DECK ABOVE FOR ROOM

SECURITY. PROVIDE ADDITIONAL METAL STUD FRAMING AS REQUIRED.

MED GAS ZONE VALVE BOX LOCATION. SEE PLUMBING DWGS.10

NOT USED11

EXISTING DOOR & DOOR HARDWARE TO REMAIN. DOOR & FRAME TO BE

REPAINTED COLOR P-6. SEE FINISH SCHEDULE.

WINDOW PROVIDED AS PART OF BASE BID. SEE ALTERNATE #2 FOR LCD

GLAZING & ASSOCIATED ELECTRICAL WORK.

WINDOW PROVIDED AS PART OF BASE BID. SEE ALTERNATE #6 FOR LCD GLAZING

& ASSOCIATED ELECTRICAL WORK.

PROVIDE SLIDING GLASS ICU DOOR W/ COMPLETE LCD GLAZING SYSTEM AT

THIS LOCTION AS PART OF BASE BID.

PROVIDE DOOR W/ LCD GLAZING AS PART OF ALERNATE #1. SEE AS601 FOR

ALTERNATE & BASE BID DOOR & FRAME TYPES. BASE BID: STANDARD GLAZED DOOR.16

NEW LOCATION FOR RELOCATED EXISTING PNEUMATIC TUBE STATION.

PROTECT DURING CONSTRUCTION. VA TUBE STATION VENDOR IS TO BE

ENGAGED FOR REQUIRED WORK & INCLUDED IN GC'S CONSTRUCTION

CONTRACT. CONTACT VENDOR FOR EXACT SCOPE OF WORK (PEVCO

SYSTEMS 800-738-2699). SEE ELECTRICAL. NEW FRAMED ROUGH

OPENING/CHASE TO BE SIZED PER SYSTEM VENDOR'S REQUIREMENTS.

TUBE SYSTEM PIPING TO BE CONFIGURED AS REQUIRED FOR

RELOCATION. PROVIDE TWO 6" DIA. PENETRATIONS THROUGH FLOOR SLAB

FOR RELOCATED TUBE RISERS. EXISTING PNEUMATIC TUBE RISERS

ABOVE THIRD FLOOR CEILING TO BE REROUTED TO NEW PENETRATIONS IN

4th FLOOR SLAB. PNEUMATIC TUBE RISERS ON 4th FLOOR TO BE

REROUTED TO RELOCATED TUBE STATION & ABOVE CEILING TO EXISTING

RISER PENETRATION THROUGH 5th FLOOR SLAB. PROTECT FLOOR

PENETRATIONS AS REQUIRED TO MAINTAIN FIRE-RATING.

EXISTING 20 MIN. DOUBLE EGRESS DOORS TO BE REPLACED W/ TEMPORARY 1-

HOUR FIRE RATED DOORS FOR DURATION OF CONSTRUCTION. NEW FIRE RATED

AUTOMATIC DOUBLE EGRESS DOORS TO BE PROVIDED AS PART OF NEW WORK.

FOR DURATION OF CONSTRUCTION, SIGN TO BE PROVIDED ON OUTSIDE OF

DOORS INDICATING "NO EXIT". EXISTING SIGNS & DIRECTIONAL ARROWS

POINTING TO AREA OF WORK ARE TO BE COVERED.

PUSH BUTTON LOCATION FOR NEW AUTOMATIC DOOR.19

FEC FIRE EXTINGUISHER CABINET

HATCH REPRESENTS APPROXIMATE AREA OF REQUIRED

FLOOR LEVELING AT EXISTING SLAB DEPRESSION.

XFEC EXISTING FIRE EXTINGUISHER CABINET

SMOKE PARTITION (SEE FLOOR PLANS

FOR WALL AND DOOR DESIGNATIONS)

1 HR. FIRE AND SMOKE BARRIER PER UL #419

(SEE FLOOR PLANS FOR WALL AND DOOR

DESIGNATIONS)

1 HR. FIRE BARRIER PER UL #419 (SEE FLOOR

PLANS FOR WALL AND DOOR DESIGNATIONS)

EXISTING 1 HR. FIRE AND SMOKE BARRIER

EXISTING 2 HR. FIRE AND SMOKE BARRIER

1 2 43 5 6 7 8 9

D

EP

AR

TM

EN

T

O F

VE

TE

R

AN

S

AF

FA

IR

SDATE

PROJECT NO.

DRAWING NO.

FILE NAME

A:Projects/2006- 1111.06

PROJECT TITLE

BUILDING NUMBER CHECKED DRAWN

WILLIAM JENNINGS BRYAN DORN

V A MEDICAL CENTER

COLUMBIA, SOUTH CAROLINA

DRAWING TITLE

APPROVED : CHIEF, LOGISTICS

APPROVED : MED CTR SAFETY MANAGER

APPROVED : INFECTION CONTROL

APPROVED : CHIEF OF STAFF

APPROVED : ASSOC DIR FOR PATIENT/

NURSING SERVICES

APPROVED : DIR., INFRASTRUCTURE

APPROVED : ASSOCIATE DIRECTOR

1 2 43 5 6 7 8 9

A

B

C

D

E

F

DATEREVISIONS

APPROVED : MEDICAL CENTER DIRECTOR

FINAL CONTRACT DOCUMENTS

FULLY SPRINKLERED

APPROVED : STATION ENERGY MANAGER

05.21.10

544-322

AS101

RELOCATE ICU TO 4 EAST

TNS/PAF KJT

REFERENCE FLOOR PLAN

GENERAL NOTES

SCALE: 1/8" = 1'-0"AS101

FLOOR PLAN- REFERENCEA1

LIFE SAFETY WALL DESIGNATIONS

KEY NOTES

PLAN NORTH

LEGEND

A

B

B

F

F

G

G

H

H

I

I

J

J

K

K

C

C

1 1

2 2

3 3

4 4

NURSE MGR

4C163

STRETCHER / EQUIP.

STORAGE

4C111

CCU/MICU BED

4C109

CCU/MICU ISO BED

4C107A

CCU/MICU BED

4C106

PCU BED

4C101

CONF./STOR. ROOM

4C140

PCU/ISO BED

4C122APCU BED

4C120

PCU BED

4C118

CCU/MICU ISO BED

4C117ACCU/MICU BED

4C116

CCU/MICU BED

4C115CCU/MICU BED

4C114

CCU/MICU BED

4C113

CCU/MICU BED

4C112

ON CALL

4C161

CLEAN UTILITY

4C164

LINEN

4C165 STAFF TOILET

4C156

SOILED UTILITY

4C160

BREAK ROOM

4C152

T.S.C.

4C121 NOURISHMENT

4C147

H.A.C.

4C148

CONFERENCE

4C145

MED GAS

4C159

CLEAN UTILITY

4C151

LINEN

4C144

STAFF TOILET

4C143

NURSE SUPER/CLIN.

PHARM

4C153

SOILED UTILITY

4C150

CORRIDOR

4C170

CORRIDOR

4C166

STAIR

BATH

4C102A

BATH

4C103A

ANTEROOM

4C107

75 LOCKERS

BATH

4C101A

PCU/ISO BED

4C100A

PCU BED

4C102

PCU BED

4C119

11' - 8" 14' - 8" 14' - 9" 14' - 9 1/2" 14' - 11 1/2" 14' - 7" 14' - 9" 14' - 7" 15' - 1" 14' - 11" 15' - 2" 14' - 5"

CCU/MICU ISO BED

4C108A

BATH

4C118A

BATH

4C119A

BATH

4C120A

BATH

4C122B

AS113

A1

AS115

A1

BIOMED

4C155

VE

RI

FY

9"

CL

EA

R

8'

- 0

5"

2' - 6 1/2"

VERIFY

8' - 1 1/2" 26' - 0" 6' - 5" 28' - 9" 6' - 5"

AS114

A1

VE

RI

FY

4"

1/ 2"

7"

STORAGE

4C157

MED RM

4C158

PCU BED

4C103

CCU/MICU ISO BED

4C104A

CCU/MICU BED

4C105

HVAC

4C131

ANTEROOM

4C108

D

D

VERIFY

26' - 4" 14' - 9" 14' - 9 1/2" 14' - 11 1/2" 14' - 7" 14' - 9" 14' - 9" 14' - 11" 14' - 11" 15' - 2" 14' - 5"

AS110

A3

AS110

A6

ANTE ROOM

4C104

ANTE ROOM

4C100

PROCEDURE ROOM

4C141

CONF. ROOM

4C139

MEDS RM

4C142

NURSE'S STATION

4C149

NURSE'S STATION

4C149

ANTE ROOM

4C122

BATH

4C100B

ANTE ROOM

4C117

AS110

A1

AS111

A1

C

LE

AR

8'

0"

VE

R

IF

Y

8'-0" CLEAR

C

LE

AR

8'

0"

3' - 10"

CLE

AR8'

- 0

CLEAR

6' - 0"

C

LE

AR

8'

0"

CLEAR

8' - 0"

VE

R

IF

Y

/2

C

LE

AR

8'

0"

27' - 6" 6' - 5"

C

LE

AR

8'

0"

8' -0

" C

LE

AR

VE

R

IF

Y

/2

CLE

AR8'

- 0

3' - 1"

CLEAR

8' - 0"

3' - 3"

1' - 3"

1'

3"

AS111

A4

8' -0

" C

LE

AR 10' - 6"

8' - 1"

AS115

A5

AS112

A4

XFEC

CLEAR

6' - 0"

CLEAR

6' - 0"

9'

1"

/2

AS112

A1

1.1

9.1

7.1

6 6

1.1

174' - 3"

174' - 3"

1.1 1.1

9.1

1.1

9.1

6 6

5 9

1.1 1.1

1.1

1.1

1.1 1.1

9.1

1.1

9.1

1.1

9.1

1.1

9.1

3 2

7.1

FEC

FEC

FEC

8 8 8 8

8 88

6 55

6 7

1.1

1.1

CCU/MICU BED

4C110

1. PRIOR TO CONSTRUCTION, CONTRACTOR TO THOROUGHLY FIELD VERIFY ALL

DIMENSIONS AND NOTIFY VA PROJECT ENGINEER OF PROBLEM DISCREPANCIES BEFORE

PROCEEDING.

2. DIMENSIONS ARE FROM FINISH FACE OF EXISTING MATERIAL TO FACE OF STUD AT

NEW WALLS UNLESS OTHERWISE NOTED. ASSUME 5" NOMINAL WIDTH FOR NEW WALLS

UNLESS OTHERWISE NOTED.

3. "CLEAR" DIMENSIONS ARE MEASURED FROM FINISH FACE OF WALL TO FINISH FACE OF

WALL TO INDICATE MINIMUM CLEARANCE REQUIRED.

4. ADJUST DIMENSIONS TO ALIGN NEW WALLS WITH EXISTING CONSTRUCTION. "VERIFY"

DIMENSIONS INDICATE FLEX AREAS FOR FIELD ADJUSTMENTS AND ALIGNMENT W/

EXISTING CONSTRUCTION. NOTIFY VA PROJECT ENGINEER OF DISCREPANCIES

EXCEEDING 2".

5. SEE ENLARGED PLANS FOR ADDITIONAL DIMENSIONS AND NOTES

6. UNLESS SHOWN & DIMENSIONED OTHERWISE, DOOR OPENING ON HINGE SIDE TO BE

LOCATED 4" FROM ADJACENT WALL.

7. SEE GI001, AS101 & AS601 FOR NOTES REGARDING LCD GLAZING @ INTERIOR

WINDOWS & SLIDING GLASS ICU DOORS TO BE PROVIDED AS PART OF BID ALTERNATES.

SMOKE PARTITION (SEE FLOOR PLANS

FOR WALL AND DOOR DESIGNATIONS)

1 HR. FIRE AND SMOKE BARRIER PER UL #419

(SEE FLOOR PLANS FOR WALL AND DOOR

DESIGNATIONS)

1 HR. FIRE BARRIER PER UL #419 (SEE FLOOR

PLANS FOR WALL AND DOOR DESIGNATIONS)

EXISTING 1 HR. FIRE AND SMOKE BARRIER

EXISTING 2 HR. FIRE AND SMOKE BARRIER

FEC FIRE EXTINGUISHER CABINET

XFEC EXISTING FIRE EXTINGUISHER CABINET

1 2 43 5 6 7 8 9

D

EP

AR

TM

EN

T

O F

VE

TE

R

AN

S

AF

FA

IR

SDATE

PROJECT NO.

DRAWING NO.

FILE NAME

A:Projects/2006- 1111.06

PROJECT TITLE

BUILDING NUMBER CHECKED DRAWN

WILLIAM JENNINGS BRYAN DORN

V A MEDICAL CENTER

COLUMBIA, SOUTH CAROLINA

DRAWING TITLE

APPROVED : CHIEF, LOGISTICS

APPROVED : MED CTR SAFETY MANAGER

APPROVED : INFECTION CONTROL

APPROVED : CHIEF OF STAFF

APPROVED : ASSOC DIR FOR PATIENT/

NURSING SERVICES

APPROVED : DIR., INFRASTRUCTURE

APPROVED : ASSOCIATE DIRECTOR

1 2 43 5 6 7 8 9

A

B

C

D

E

F

DATEREVISIONS

APPROVED : MEDICAL CENTER DIRECTOR

FINAL CONTRACT DOCUMENTS

FULLY SPRINKLERED

APPROVED : STATION ENERGY MANAGER

05.21.10

544-322

AS102

RELOCATE ICU TO 4 EAST

TNS/PAF KJT

DIMENSION FLOOR PLAN

SCALE: 1/8" = 1'-0"AS102

FLOOR PLAN - DIMENSIONA2

LIFE SAFETY WALL DESIGNATIONS

PLAN NORTH

TRUE NORTH

GENERAL DIMENSION NOTES

LEGEND

WALL TYPE LEGEND

WALL TYPES

TYPE

MARK

FIRE

BARRIER

RATING DESCRIPTION DETAIL

1 EXISTING INTERIOR PARTITION. PATCH

AS REQ'D FOR CONTINUOUS GYP BRD

FINISH AND ALIGN W/ NEW ADJACENT

CONSTRUCTION. NEW & EXISTING GYP

BRD TO BE PAINTED (P-1). SEE FINISH

SCHEDULE

1.1 EXISTING EXTERIOR WALL. PATCH AS

REQ'D. AT REMOVED INTERIOR

PARTITION LOCATIONS FOR

CONTINUOUS GYP BRD FINISH. NEW &

EXISTING GYP BRD TO BE PAINTED

(P-1). SEE FINISH SCHEDULE. SEE

FINISH PLAN FOR NEW RIGID VINYL

SHEET LOCATIONS.

2 1 HR FIRE

/ SMOKE

EXISTING 1-HOUR FIRE/SMOKE

BARRIER. NEW AND EXISTING

PENETRATIONS TO BE PROPERLY

SEALED AND PROTECTED TO

MAINTAIN RATING. PATCH AS REQ'D TO

MAINTAIN RATING AT REMOVED WALL

LOCATIONS. NEW & EXISTING GYP BRD

TO BE PAINTED ON

CORRIDOR/PATIENT ROOM/EQUIP

STORAGE SIDE (P-1). SEE FINISH

SCHEDULE. SEE FINISH PLAN FOR

RIGID VINYL SHEET LOCATIONS.

3 2 HR FIRE

/ SMOKE

EXISTING 2-HOUR FIRE/SMOKE

BARRIER. NEW AND EXISTING

PENETRATIONS TO BE PROPERLY

SEALED AND PROTECTED TO

MAINTAIN RATING.

4 EXISTING WALL TO BE UPGRADED TO

SMOKE PARTITION.

B3/AS301

SIMILAR

5 NEW WALL, 3 5/8" METAL STUDS, 3-1/2"

SOUND ATTENUATION BLANKETS, W/

5/8" GYP BRD EACH SIDE UNLESS

SHOWN OTHERWISE.

6 NEW SMOKE PARTITION W/ 3-1/2"

SOUND ATTENUATION BLANKETS.

PROVIDE 6" METAL STUDS AT

PLUMBING WALLS.

7 1 HR

UL# 419

NEW 1-HOUR FIRE BARRIER W/ 3-1/2"

SOUND ATTENUATION BLANKETS.

PROVIDE 6" METAL STUDS AT

PLUMBING WALLS

7.1 1 HR FIRE

/ SMOKE

UL#419

NEW 1-HOUR FIRE/SMOKE BARRIER W/

3-1/2" SOUND ATTENUATION

BLANKETS. PROVIDE 6" METAL STUDS

AT PLUMBING WALLS

8 NEW CHASE W/ 3-1/2" SOUND

ATTENUATION BLANKETS. CHASE TO

ACCOMODATE CARRIERS AT WALL

MOUNTED LAVS, SINKS, & TOILETS,

ETC. CONSTRUCT AS SMOKE

PARTITION WHERE REQ'D.

9 NEW PLUMBING WALL, W/ 3-1/2" SOUND

ATTENUATION BLANKETS. PROVIDE 6"

METAL STUDS W/ 5/8" GYP BD EACH

SIDE.WALL TO ACCOMODATE

CARRIERS AT WALL MOUNTED LAVS.

9.1 NEW PLUMBING WALL, W/ 3-1/2" SOUND

ATTENUATION BLANKETS. PROVIDE 8"

WIDE METAL STUD FRAMING W/ 5/8"

GYP BD EACH SIDE.WALL TO

ACCOMODATE CARRIERS AT WALL

MOUNTED LAVS.

B5/AS301

SIMILAR

B3/AS301

B1/AS301

B1/AS301

SIMILAR

B7/AS301

B5/AS301

B

B

F

F

G

G

H

H

I

I

J

J

K

K

C

C

1 1

2 2

3 3

4 4

STRETCHER / EQUIP.

STORAGE

4C111

CCU/MICU BED

4C109

CCU/MICU ISO BED

4C107A CCU/MICU BED

4C106

PCU BED

4C103

PCU BED

4C102

PCU BED

4C101

PCU/ISO BED

4C100A

CONF./STOR. ROOM

4C140

SOILED UTILITY

4C150

NURSE SUPER/CLIN.

PHARM

4C153

STAFF TOILET

4C143

CLEAN UTILITY

4C151

LINEN

4C144

CONFERENCE

4C145

H.A.C.

4C148

NOURISHMENT

4C147

BREAK ROOM

4C152

T.S.C.

4C121

SOILED UTILITY

4C160

CLEAN UTILITY

4C164

LINEN

4C165

ON CALL

4C161

STAFF TOILET

4C156

CORRIDOR

4C166

CCU/MICU BED

4C112

CCU/MICU BED

4C113

CCU/MICU BED

4C114

CCU/MICU BED

4C115

CCU/MICU BED

4C116

CCU/MICU ISO BED

4C117A

PCU BED

4C118

PCU BED

4C119

PCU BED

4C120

PCU/ISO BED

4C122A

BIOMED

4C155

L

3 3

CCU/MICU ISO BED

4C108A

9' - 0"

9' - 0"

9' - 0"

AS104

D4

AS104

A4

7' - 6"

9' - 0"

7' - 6"

AS104

D3

AS104

D1

NURSE MGR

4C163

BATH

4C103A

BATH

4C102A BATH

4C101A

BATH

4C122BBATH

4C120A

BATH

4C119ABATH

4C118A

7' - 6" 7' - 6"

AS104

A1

D

D

9' - 0"

9' - 0"

ANTE ROOM

4C100

CCU/MICU ISO BED

4C104A

ANTE ROOM

4C104

CCU/MICU BED

4C105

ANTEROOM

4C107

ANTEROOM

4C108

9' - 0"

9' - 0" 9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

7' - 6"

9' - 0" 9' - 0" 9' - 0"

9' - 0"

7' - 6"

9' - 0"

7' - 6"

BATH

4C100B

ANTE ROOM

4C122

7' - 6"

9' - 0"

7' - 6"

7' - 6"

9' - 0"

9' - 0"

9' - 0"

ANTE ROOM

4C117

9' - 0"

33333 9' - 0" 9' - 0"

9' - 0" 9' - 0"

4 4 4

7' - 6"STORAGE

4C157

MED GAS

4C159

NURSE'S STATION

4C149

MEDS RM

4C142

9' - 0"

9' - 0"

9' - 0"

8' - 0"

7' - 0"

9' - 0"

9' - 0" 9' - 0" 9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0" 9' - 0"

9' - 0"

8' - 0"

8' - 0"

8' - 0"

8' - 0" 8' - 0"

8' - 0"

8' - 0" 8' - 0"

8' - 0"

8' - 0" 8' - 0"

8' - 0"

8' - 0"8' - 0"

8' - 0"

8' - 0"

9' - 0"

9' - 0"

7' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"9' - 0"

L

L

L

L

L

L L

L L

L

L L

L

L

L

L

L L

L

9' - 0" 9' - 0" 9' - 0"

7' - 6"

L

L

L L L

L

L L

L

L

L

L

LL

LL

LLL

9' - 0"

9' - 0"

L

MED RM

4C158

AS104

A3

9' - 0"

PROCEDURE ROOM

4C141

CONF. ROOM

4C139

9' - 0"

C C C C C C

C C C C

CCCC

CCCCCC

L

L

HVAC

4C131 P-3 P-4

P-4P-3P-4

P-4

P-3 P-4 P-3

P-4 P-3

P-2

P-2

P-2

P-2

P-2

7'

7'

C

7' - 0"

7' - 0"

7' - 0"

7' - 0" 7' - 0"

7' - 0" 7' - 0"

7' - 0"

7' - 0"

7' - 0"7' - 0"

7' - 0"7' - 0"7' - 0"

7' - 0"

7' - 0"

7' - 0"

7' - 0"

7' - 0"

7' - 0"

7' - 0"

7' - 0"

7' - 0"

CCU/MICU BED

4C110

TVW TVW TVW TVW

TVW

TVW

TV

W

TVW TVW

TVW TVW

TV

W

TVWTVWTVW

TVW

TVW

TVW

TVW

TVW

TVW

TV

W

TV

W

TV

W

6666666

6 6 6 6 6 6

6 6 6 6

P-2

P-2

TV

W

777777

7 7 7 7 7 7

7 7 7 7

CORRIDOR

4C168

CORRIDOR

4C170

CORRIDOR

4C167

777 77 77

7 7 7 7 7 7

7 7 7 7

X' - X"

RECESSED LIGHT FIXTURE. SEE MPE.

2x4 FLUORESCENT LIGHT FIXTURE. SEE ELEC.

2x4 FLUORESCENT LIGHT FIXTURE WITH EMERGENCY BACKUP. SEE ELEC.

VIDEO CAMERA. SEE ELECTRICAL. SEE ALTERNATE #4. BASE BID: OMIT VIDEO

SURVEILLANCE SYSTEM.

WALL MOUNTED TV BRACKET. ELECTRICAL OUTLETS TO BE CONCEALED

BEHIND TV's.

INTERNALLY ILLUMINATED EXIT SIGN. SEE MPE.

2x2 LAY-IN ACOUSTICAL CEILING SYSTEM. SEE FINISH SCHEDULE.

PAINTED GYP. BOARD SOFFIT. SEE AS302. PAINT ALL SIDES P-1 UNLESS

OTHERWISE NOTED.

PATIENT LIFT SYSTEM. SOLE SOURCE ITEM. MAIN CARRYING RAILS TO BE

LOCATED BELOW CEILING GRID.

CUBICLE CURTAIN TRACK. SEE SPEC SECTION 10 21 23.

PAINTED MOISTURE RESISTANT GYP. BOARD CEILING AT SHOWER

LOCATIONS.

HVAC SUPPLY GRILL. SEE MPE.

HVAC RETURN GRILL. SEE MPE.

HVAC EXHAUST GRILL. SEE MPE.

FINISH CEILING HEIGHT.

ACCESS PANEL. SEE AS104.

SPEAKER. SEE MPE.

CEILING MOUNTED SIGN. SEE AS703.

STRIP LIGHT FIXTURE. SEE ELECTRICAL.

C

L

TVW

NO WORK IN THIS AREA.

NO FINISH CEILING IN THIS AREA. SEE MPE REGARDING INFO ON CEILING DEVICES.

CLEAN ROOM TYPE ACT CEILING IN THIS SPACE. SEE FINISH SCHEDULE.

4 GYP BRD CEILING (PAINTED P-5) ON MTL. CEILING JOISTS. SEE DETAILS 6&7 / SHEET

S1 FOR CEILING FRAMING DETAILS.

CEILING MOUNT MED GAS OUTLET LOCATION. SEE MPE.5

SEE ALTERNATE #1 (SHEET GI001) REGARDING LCD GLAZING IN DOORS.

CUBICLE CURTAINS SHALL NOT BE PROVIDED AT THIS LOCATION IF LCD

GLAZING IS PROVIDED AT THIS LOCATION. BASE BID: PROVIDE CUBICLE

CURTAINS AS SHOWN.

SEE ALTERNATES #2 & #6 REGARDING LCD GLAZING AT INTERIOR

WINDOWS. IF LCD GLAZING IS PROVIDED, CUBICLE CURTAINS SHALL NOT

BE PROVIDED. BASE BID: PROVIDE CUBICLE CURTAINS AS SHOWN.

SMOKE PARTITION (SEE FLOOR PLANS

FOR WALL AND DOOR DESIGNATIONS)

1 HR. FIRE AND SMOKE BARRIER PER UL #419

(SEE FLOOR PLANS FOR WALL AND DOOR

DESIGNATIONS)

1 HR. FIRE BARRIER PER UL #419 (SEE FLOOR

PLANS FOR WALL AND DOOR DESIGNATIONS)

EXISTING 1 HR. FIRE AND SMOKE BARRIER

EXISTING 2 HR. FIRE AND SMOKE BARRIER

1 2 43 5 6 7 8 9

D

EP

AR

TM

EN

T

O F

VE

TE

R

AN

S

AF

FA

IR

SDATE

PROJE…