W912ER-23-R-0001 Bulk POL_AM 0006_Drawings.pdf
PDF 1 MB Posted
- Solicitation number
- W912ER23R0001
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
C T
N
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
P L
D
A T
E
F I L
E N
A M
E
A N
S I
D
U
J O
R D
A N
B U
L K
P
E T
R O
L E
U M
O
I L
A
L
B R
I C
A N
O
R A
G E
US Army Corps of Engineers ®
J R
NOT FOR
CONSTRUCTION
B ak er -J ac ob s, J
V
R M
Y
C
O R
P
F
E
N G
I N
E E
R S
M I D
D
E
S
T
D
I S
T R
I C
T
P O
B
X
W I N
C H
E S
T E
R
V
A
J U
Y
W
E R
R
G-011
AM 0006
G E
N E
R A
L
I N
D E
X
O
F
D
R A
W I N
G S
V
G
A R
S K
E
V
G
A R
S K
E
M
P
R A
T T
M
P
R A
T T
J R
G
G
N
R
E V
I S
I
A
W
A
M E
N D
M E
D E
C
R
E V
I S
I
A
W
A
M E
N D
M E
J A
N
D
M
UPUP UPUP
TA
N K A
XIS
II
TA
N K A
XIS
I
0°
0°
149°
45°
I.
D
O
F C
O N
C R
E T
E
90°
180° A1
A S-301
B1
A S-302
D5
A S-502
2060 TYP
O .D
O
F C
O N
C R
E T
E
TYP 3 PLCS
T A
N K
A X
IS
I
TANK AXIS II
0°
0°
9°
0°
9°
A1
A S-301
B1
A S-302
D5
A S-502
D1
A S-502
6200 8000
D1
A S-502
I.
D
O
F C
O N
C R
E T
E
T
Y P
14200
O .D
O
F C
O N
C R
E T
E
B a k er
-J a co b s, J
V
PLAN NORTH
1:100
10m2m 8m6m4m0m
DIM. NOTE & NORTH
KEY PLAN
TANK #2 TANK #1
PLAN NORTH
TANK #2 TANK #1
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L
O T
D A
T E
F
IL
E N
A M
E
M
ID
D L
E E
A S
T D
IS
T
R
IC
T P
.O
B O
X
W
IN
C H
E S
T E
R
V A
-1
C:\Users\bterry\OneDrive - Jacobs\Documents\JR-479505B-DM-SAI-PUHO_Bradly.Terry.rvt
1/27/2023 9:09:34 AM
/2
/2
:0 :3
A
M
U D
.4
J O
R D
A N
J U
L Y
W
E R
-2 -R
-0
B U
L K
P E
T R
O L E
U M
O
IL
A
N D
L U
B R
IC
A
N T
S S
T O
R A
G E
J R
J R
-4
A
-S -1
P
N -0
B
T E
R R
Y
D
M A
R T
IN
J
H O
D S
O N
M P
R A
T T
T A
N K
R O
O F
O V
E R
A L L P
L A
N S
AM 0002
A S-101
1 : 100A5
TANK 1 ROOF PLAN
1 : 100D1
TANK 2 ROOF PLAN
GENERAL SHEET NOTES
SHEET KEYNOTES
A. FOR GENERAL STRUCTURAL NOTES SEE SHEETS SS001
AND SS002. FOR CUT N' COVER GENERAL NOTES AND
DESIGN CRITERIA SEE A S-001.
B. DO NOT SCALE DRAWINGS TO DETERMINE SPECIFIC
DIMENSIONS OR QUANTITIES.
C. COORDINATE SIZE AND LOCATION OF ALL FLOOR
PENETRATIONS, DOOR LOCATIONS, CURBS, STEM WALLS,
ETC WITH OTHER ALL DISCIPLINE DRAWINGS PRIOR TO
PLACING ANY CONCRETE OR REINFORCEMENT.
D. DIMENSIONS SHOWN ARE TO FACE OF CONCRETE WALLS
OR CENTERLINE OF COLUMNS, PENETRATIONS, UNLESS
NOTED OTHERWISE.
E. FOR TANK COORDINATES AND ORIENTATION SEE CIVIL
DRAWING CS101.
1 LEAK DETECTION ACCESS CONDUIT.
2 MANWAY ACCESS VAULT, TYP OF 3 AT EACH TANK.
3 PUMPHOUSE REINFORCED CONCRETE FOUNDATION WALL.
4 FOUNDATIONS FOR ROLLING COVERS
5 LEAKAGE TEST PIPE WITH SCREW CAP. SEE DETAIL A4 ON A
S-303. TYPICAL IN 4 PLACES AS SHOWN.
R
E V
IS
E
D I .A
.W A
M E
N D
M E
N T
J A
N
AM 0006
T.O. STEEL FLOOR
PLATE AT SHELL
92.28
T.O. TANK SUMP
91.81
T.O. STEEL TANK
99.5
A7
A S-303
D7
A S-303
A1
A S-303
F4
A S-503
A4
A S-503
C4
A S-503
D7
A S-503
THREADED CAP
LEAKAGE TEST PIPE
38 DIA. STD WT
DIA.
TOP OF
STEEL TANK
SEAL COMPOSITE MAT
AROUND LEAKAGE
TEST PIPE
L102x102x9.5
PREFABRICATED DRAINAGE
COMPOSITE MAT
TANK SHELL
L75x75x9
M
IN
TOP PLATE
13 DIA HEADED ANCHOR
STUD AT 560 OC, EW
DIA.
CONCRETE FILL
150 DIA. HOLE FOR
254 DIA. EXTRA
STRONG PIPE (TYP)
070 1
16 DIA. BRACKET ORIENTED
TOWARDS CENTER OF TANK
AT EACH SUPPORT
380 DIA.
TANK BOTTOM
PLATE
HEX NUT
FLAT WASHER
10 DIA.
THREADED
STUD 50 LONG
@ 500 OC
6X50 CONT.
CARBON STEEL
BATTEN BAR
WITH SLOTTED
HOLES
DRAINAGE
COMPOSITE MAT
TOP PLATE
D9
A S-303
NOTES:
1. SHELL THICKNESS INCLUDES CORROSION ALLOWANCE
8mm BOTTOM PLATE
5%
TOP OF STEEL TANK
TOP OF STEEL
FLOOR PLATE
L75x75x9
10mm TANK SHELL
6mm
TOP PLATE
A9
A S-303
PREFABRICATED DRAINAGE
COMPOSITE MAT
6x75 CONT. CARBON
STEEL PLATE WITH
SLOTTED
HOLES @ 250 O.C.
10 DIA.
HEX BOLT
40mm LONG
FLAT WASHER
PREFABRICATED
DRAINAGE
COMPOSITE MAT
6x50 CONT.
CARBON STEEL
BATTEN BAR WITH
SLOTTED HOLES
@ 250 O.C.
10 DIA.
HEX HEAD NUT
WEEP HOLE
BOTTOM
PLATE
TANK
SHELL
B a k er
-J a co b s, J
V
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L
O T
D A
T E
F
IL
E N
A M
E
M
ID
D L
E E
A S
T D
IS
T
R
IC
T P
.O
B O
X
W
IN
C H
E S
T E
R
V A
-1
C:\Users\bterry\OneDrive - Jacobs\Documents\JR-479505B-DM-SAI-PUHO_Bradly.Terry.rvt
1/27/2023 9:09:36 AM
/2
/2
:0 :3
A
M
U D
.4
J O
R D
A N
J U
L Y
W
E R
-2 -R
-0
B U
L K
P E
T R
O L E
U M
O
IL
A
N D
L U
B R
IC
A
N T
S S
T O
R A
G E
J R
J R
-4
B
-S -3
S
E -0
B
T E
R R
Y
D
M A
R T
IN
J
H O
D S
O N
M P
R A
T T
S T
E E
L T
A N
K S
E C
T
IO
N
D E
T A
IL
S
AM 0002
A S-303
1 : 50A S-104
E1 STEEL TANK ELEVATION
1 : 2A S-501
A4 LEAK DETECTION PIPE
1 : 5A S-303
D7 ANCHOR STUD DETAIL
1 : 20A S-303
A7 PIPE SUPPORT DETAIL
1 : 1A S-303
D9 BATTEN BAR DETAIL
1 : 2A S-303
A1 STEEL TANK WALL DETAIL
1 : 1A S-303
A9 DETAIL
1:50
5m1m 4m3m2m0m
1:20
2m0.4m 1.6m1.2m0.8m0m
TYP
R
E V
IS
E
D I .A
.W A
M E
N D
M E
N T
J A
N
TANK WALL (CONC)
STEEL TANK
SLOPE
MEMBRANE
WATERPROOFING
PROTECTION
BOARD
MEMBRANE
WATERPROOFING
D13 RADIAL
"U" BAR
@ 300 O.C.
D18 @ 150 WITH
STANDARD HOOK
D19 RADIAL BARS
WITH STD HOOK
@ 250 OC T&B
CONTROL JOINT
SEE NOTE 2
5%
SEE ROOF PLAN FOR
REINFORCEMENT
D22 VERTICAL BARS
WITH STD HOOK
@ 200, EF; CONNECT
W TYPE 2 MECH
SPLICE CONNECTOR
TOP OF BERM
SEE GRADING
PLAN
TOP OF STEEL TANK EL.=99.5
50 PROTECTIVE
GROUT
D13 "U" BAR @ 300
D16 VERTICAL
BARS, 7200 LONG
@ 200, EF
D22 VERTICAL BARS
x 3000 LONG @ 200, EF
150 FLAT OR
DUMBBELL
WATERSTOP
NOTES:
1. HORIZONTAL BARS IN TANK WALL SHALL HAVE CLASS "B"
TENSION LAP SPLICES. SPLICES IN ADJACENT HORIZONTAL
BARS SHALL BE SPACED A MINIMUM OF 750. DO NOT SPLICE
HORIZONTAL BARS AT CONSTRUCTION JOINT. SEE DETAIL
E1/A S-103.
2. ROUGHEN SURFACE OF CONCRETE @ JOINT TO AN
AMPLITUDE OF 6mm PRIOR TO PLACEMENT OF ADJACENT
CONCRETE AND CLEAN BY SANDBLASTING, HIGH-PRESSURE
WATER JET OR OTHER APPROVED METHOD.
D
H
O R
IZ
O
N T
A L
B A
R S
D
H
O R
IZ
O
N T
A L
B A
R S
35050
S P
A
S P
A
S P
A C
E S
S
P A
30050
75 CLR.
PREFABRICATED DRAINAGE
COMPOSITE MAT
38 DIA. STD WT
STEEL PIPE SEE PLAN
TYP. SLAB REINF.
SEE PLAN ON S-102
MEMBRANE
WATERPROOFING
CONCRETE
LEVELING COURSE
PROTECTIVE
GROUT
TOP OF STEEL
FLOOR PLATE AT
SHELL EL.=92.28
50 CLR
75 CLR
S E
E C
IV
IL
C L R
5 C
L R
A4
A S-303
75 GROUT W/ FUEL
RESISTANT EPOXY
RESIN COATING
BOTTOM PLATE
FUEL RESISTANT EPOXY
RESIN COATING
FLOOR SLAB
SLOPE
5%5%
2%
REINFORCED CONC.
CONCRETE
LEVELING COURSE
GROUT FINISH
100 DIA.
LEAKAGE
DETECTION PIPE
PROTECTIVE GROUT
WATERPROOFING
MEMBRANE
GROUT FINISH
D16 @ 300
EACH WAY,
EACH FACE
W200
(BEYOND)
L51x51
TO W200
EL.=91.81
TYP. SLAB REINF.
SEE PLAN
ON A S-102
D16@300
EL.=91.34
EL.=91.13
A1
A S-501
T Y
P
C L R
T Y
P
C
L R
0 500
2000 DIA
13 13
G
R O
U T
2407.342
PUMPHOUSE WALL
C.J.
SLOPE
REINF CONC
ROOF SLAB
STEEL PIPE
COLUMN (BEYOND)
(3) D16 HORIZ, EF
FINISHED FLOOR
EL = 100.00
100 WATERSTOP
SEE SLAB PLAN
FOR SPACING
PRECAST WALL; SEE ARCH;
CONNECTORS AS REQUIRED
BY PRECAST MFR (TYP)
W
S
FOR CONC FILL
150 DIA HOLE
C L R
C L R
D16 @ 450, EW, EF
D16 VERT DOWEL @ 450;
WITH MATCHING WALL
VERTS
L A
P
TOC EL = 100.50 TYP
D16 VERT DOWEL @ 450
PROTECTION BOARD
MEMBRANE WATERPROOFING
TOC EL = 101.60 SIM
D16 @ 300 EACH
WAY, EACH FACE
D16 @ 300
TYP. SLAB REINF.
SEE PLAN ON S-202
5%
13 DIA. EXPANSION
ANCHOR BOLT W/
150 MINIMUM
EMBEDMENT (TYP. OF 4)
GROUT,
SLOPE TO
DRAIN
W200x15 TYP.
L51x51x4.8
(BETWEEN
WT, TYP IN
3 ROWS)
E4
A S-501
2000 DIA.
100 300 300 300 300 300 300 100
T Y
P
C
L R
T Y
P
C L R
2420 EW
EL. VARIES
PIPE INVERT
EL. VARIES
LEAKAGE
DETECTION PIPE
D16 @ 300
TYP. SLAB REINF.
SEE PLAN
TYP.
C
LR
T Y
P
560400300
STEEL TANK
75 GROUT W/ FUEL
RESISTANT EPOXY
RESIN COATING
5%
SLAB
REINF (TYP),
SEE PLAN
100 DIA
LEAKAGE
DETECTION
PIPE, SEE
NOTE 2
WATERPROOFING
MEMBRANE
50 GROUT
CONCRETE LEVELING
COURSE
D19 @ 300 E.W.
PIPE INVERT @ VERT
PIPE EL = 90.93
D16 @ 300 EW (TYP)
MEMBRANE
WATERPROOFING
PROTECTION
BOARD
TOP OF STEEL FLOOR
PL AT SHELL EL = 92.28
CJ, ROUGHEN
SURFACE, SEE
NOTE 1
600 DIA SS PIPE,
SEE NOTE 2
NOTES:
1. ROUGHEN CONCRETE SURFACE OF CONCRETE AT JOINT TO AN AMPLITUDE OF
6.5mm PRIOR TO PLACEMENT OF ADJACENT CONCRETE AND CLEAN BY
SANDBLASTING, HIGH-PRESSURE WATER JET OR OTHER APPROVED METHOD.
2. PROVIDE STAINLESS STEEL LEAK DETECTION PIPE.
D16 @ 300 EW
PROTECTION
BOARD
MEMBRANE
WATERPROOFING
D16 @300
WITH STD HOOK
50 GROUT
WATER-
PROOFING
MEMBRANE
PROTECTION BOARD
250 620 250
F1
A S-502
F3
A S-502
TOP OF STEEL TANK EL.=99.5
TOC EL = 101.9
STEEL TANK;
SEE DETAILS
B a k er
-J a co b s, J
V
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L
O T
D A
T E
F
IL
E N
A M
E
M
ID
D L
E E
A S
T D
IS
T
R
IC
T P
.O
B O
X
W
IN
C H
E S
T E
R
V A
-1
C:\Users\bterry\OneDrive - Jacobs\Documents\JR-479505B-DM-SAI-PUHO_Bradly.Terry.rvt
1/27/2023 9:09:38 AM
/2
/2
:0 :3
A
M
U D
.4
J O
R D
A N
J U
L Y
W
E R
-2 -R
-0
B U
L K
P E
T R
O L E
U M
O
IL
A
N D
L U
B R
IC
A
N T
S S
T O
R A
G E
J R
J R
-4
A -S
-5
D T
-0
B
T E
R R
Y
D
M A
R T
IN
J
H O
D S
O N
A p p ro v e r C
O N
C R
E T
E D
E T
A
IL
S
AM 0002
A S-501
1 : 20A S-301
C1 TANK CONCRETE WALL ELEVATION
1 : 20A S-301
E4 TANK SUMP DETAIL
1 : 20A S-302
C5 DETAIL
1 : 20A S-302
A1 TANK SUMP DETAIL
1 : 20A S-102
A5 LEAK DETECTION PIPE
1:20
2m0.4m 1.6m1.2m0.8m0m
GRAPHIC SCALE
1 : 20A S-302
C8 LEAK DETECTION WELL AT BOTTOM
1 : 20A S-302
F8 LEAK DETECTION WELL TOP ELEVATION
ACCESS HATCH
R
E V
IS
E
D I .A
.W A
M E
N D
M E
N T
J A
N
| JR-479505-G-011GN-06 |
| JR-479505B-DM-SAI-PUHO_A S-101 - TANK ROOF OVERALL PLANS |
| JR-479505B-DM-SAI-PUHO_A S-303 - STEEL TANK SECTION & DETAILS |
| JR-479505B-DM-SAI-PUHO_A S-501 - CONCRETE DETAILS |
File details come from the government source that posted it. Updated .