About this file
This package contains plans and drawings for the McNary Levee Drainage Pump Upgrade project solicited by the Department of the Army Corps of Engineers Walla Walla Engineering District. The drawings show the demolition and upgrades required at Pump Station 12-2, including upgrading the electrical service from overhead to underground, installing a new manual transfer switch, providing motor soft starters with full bypass, and upgrading the motor control center. The project will demolish existing overhead utility lines and transformers, install new underground feeders, transition utility service from overhead to underground, and connect a portable generator. The solicitation number for the project is W912EF23B0002.
View the file
Other files for this federal contract opportunity
Show all 47
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A N
S I
D
F
IN
A L
E Q
U
IP
M E
N T
U P
G R
A D
E
L E
V E
E D
R A
IN
A
G E
P U
M P
S T
A T
IO
N
S
C O
L U
M B
IA
R
IV
E
R O
R E
G O
N A
N D
W A
S H
IN
G
T O
N
M C
N A
R Y
L O
C K
A N
D D
A M
W
E F
B
A P
R
IL
W
L L
A W
A L
L A
W
A S
H
IN
G T
O N
N
R
D A
V E
W A
L L
A W
A L
L A
D
IS
T R
IC
T
F
IL
E N
O
K E
V
IN
R E
N S
H A
W
P .E
IN
D
E X
P U
M P
S T
A T
IO
N
-2
G E
N E
R A
L
G-002
M F
L A
N A
G A
N
P
A U
T H
/2
S H
E E
T S
-5 D
E L
E T
E D
F R
O M
V O
L U
M E
A S
E
M D
L -1
-0 -5
/1
F
L A
N A
G A
N
VOLUME 7
D S
A
E C
S c re e n
F u ll
S iz e .d s c ri p t
P D
A
E C p d f.
p lt c fg
:1
:5
A
M
/7 /2
M N a
\M
N a
V
G -0
X X
X .d g n
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R
N
S I
D
F
IN
A L
E Q
U
IP
M E
N T
U P
G R
A D
E
L E
V E
E D
R A
IN
A
G E
P U
M P
S T
A T
IO
N
S
C O
L U
M B
IA
R
IV
E
R O
R E
G O
N A
N D
W A
S H
IN
G
T O
N
M C
N A
R Y
L O
C K
A N
D D
A M
W
E F
B
A P
R
IL
L L
A W
A L
L A
W
A S
H
IN
G T
O N
N
R
D A
V E
W A
L L
A W
A L
L A
D
IS
T R
E N
O
L E
V I
V A
N S
T E
D U
M P
.E
D E
M O
L
IT
IO
N
O V
E R
A L
L S
IT
E
P L
A N
P U
M P
S T
A T
IO
N
-2
P L
A N
ED101
P H
A R
P O
L E
S
S C
H E
IF
F
/2
G
N N
O T
D
L -1
-6 -5
/4
S
T A
D N
IK
VOLUME 7
D S
A
E C
S c re e n
F u ll
S iz e .d s c ri p t
P D
A
E C p d f.
p lt c fg
:1
:3
A
M
/7 /2
M N a
\M
N a
V
E D
X
X X
.d g n
A1
SCALE: 1/8" = 1'-0"
PUMP STATION 12-2 OVERALL SITE PLAN
NORTH
AT SERVICE POLE
UNDERGROUND
TRANSITION OVERHEAD TO
DEMOLISH SERVICE RISER
BY UTILITY
SERVICE LINES
DEMOLISH OVERHEAD
M
TRANSFORMERS
POLE MOUNTED
EXISTING UTILITY
UTILITY METER
EXISTING
SEE ED-501
ABANDON UG CONDUIT
DEMOLISH UG CONDUCTORS
RADIO REPEATER
PASCO POLICE
BREAKER CONDUCTORS
DEMOLISH SIPHON
EXISTING UG CONDUIT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
SCREENED EXISTING.2.
EXISTING UG ELECTRICAL DEMOLITION1.
LEGEND
EXISTING TRANSFORMER.
UTILITY TO INSTALL NEW OVERHEAD CONDUCTORS AND REPLACE 2.
CONTRACTOR TO TRENCH AND INSTALL NEW UNDER GROUND FEEDER. 1.
GENERAL SHEET NOTES
0 8'4' 16'
4"C, UG (NEW)
3-500, 1-250(N) KCMIL
1/0 (G) FROM RECEP
4"C, UG (NEW)
3-500, 1-250(N) KCMIL
POLE OVHD TO UG TRANSITION
WITH CONDUIT RISER (NEW)
WEATHERHEAD AT POLE
#6 GRD
RODS
GROUND
NEW
GRID
GROUND
EXISTING
SEC NEUTRAL
TRANSFORMER
LIGHTING
#6 GEC
TO CHECK FUSE SIZE
CONTRACTOR
A N
S I
D
F
IN
A L
E Q
U
IP
M E
N T
U P
G R
A D
E
L E
V E
E D
R A
IN
A
G E
P U
M P
S T
A T
IO
N
S
C O
L U
M B
IA
R
IV
E
R O
R E
G O
N A
N D
W A
S H
IN
G
T O
N
M C
N A
R Y
L O
C K
A N
D D
A M
W
E F
B
A P
R
IL
L L
A W
A L
L A
W
A S
H
IN
G T
O N
N
R
D A
V E
W A
L L
A W
A L
L A
D
IS
T R
E N
O
L E
V I
V A
N S
T E
D U
M P
.E
O N
E L
IN
E
D
IA
G R
A M
P U
M P
S T
A T
IO
N
-2
D
IA
G R
A M
E-601
P H
A R
P O
L E
S
S C
H E
IF
F
/2
B R
E A
K E
R C
H A
N G
E D
F R
O M
-P
O L
E T
O
-P O
L
D
L -1
-6 -5
/1
S
T A
D N
IK
VOLUME 7
D S
A
E C
S c re e n
F u ll
S iz e .d s c ri p t
P D
A
E C p d f.
p lt c fg
:1
:1
A
M
/7 /2
M N a
\M
N a
V
E -6
X X
X .d g n
A9
SCALE: NTS
PUMP 12-2 STATION POWER SINGLE LINE
DETAIL: NEUTRAL AND GROUND
SCALE: NTS
F15
MMM
3-POLE
400AF
300AT
480VAC, 600AMP, BUS, 42AIC
30A
WITH BYPASS
SOFT START
WITH BYPASS
SOFT START
WITH BYPASS
SOFT START
60 HP
PUMP 1
60 HP
PUMP 2
60 HP
PUMP 3
4 POLE SWITCHED NEUTRAL
CIRCUIT BREAKER TYPE
400 A INTERLOCKED
SERVICE ENTRANCE RATED
MANUAL TRANSFER SWITCH (MTS)
225 AF
120 AT
MCC GROUND
RECEPTACLE
480V POWER
15A
SPARE
30A
HTR
HEATER
WALL
15A
S
BREAKER
SIPHON
5A
S
BREAKER
SIPHON
5A
S
BREAKER
SIPHON
5A
#6(G), 2" C
3C-#3, #12 (G) 3/4"C
2C#12, 4P
400 AF
350 AT
4P
400 AF
350AT
(NEW)
Z=XX
480VAC WYE-G, 150KVA
12470 / 7200VAC WYE-G
3 POLE MOUNTED TRANSFORMERS
225 AF
120 AT
225AF
120AT
M METER # 30729
FRANKLING CO PUD
SHUNT TRIP TO GENERATOR CB
INCLUDES SAFETY INTERLOCK
WITH GROUNDING PLUG
3 PH, 4 WIRE
RECEPTACLE 400A
PORTABLE GENERATOR (MTS)
BLOCK
SPLICER
MCC
MCC
MCC NEUTRAL BUS
MCC GROUND BUS
MTS
AT TRANSFER SWITCH
SERVICE ENTRANCE
G
CB
MAIN
N
N
N
M
TRASH RAKE
1 HP
M NEW METER
ACTUATOR
SLIDE GATE
2 HP
20A 15A
3P, 9 KVA
480-208/120V, TRANSFORMER
PANEL
DIST
MCC
40A
SPACE
DM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
GENERAL SHEET NOTES
TO THE NEUTRAL OF THE MCC.
BE EXTENDED THROUGH THE NEW TRANSFER SWITCH AND CONNECTED
NEUTRAL FROM THE SECONDARY OF THE UTILITY TRANSFORMER SHALL
THE MCC DESIGN SHALL BE A 3 PHASE, 4 WIRE BUS. THE EXISTING
MCC NUETRAL: 3.
1008 AS SUITABLE FOR SERVICE ENTRANCE USE.
THE TRANSFER SWITCH SHALL BE SERVICE ENTRANCE RATED PER UL
SWITCH INTERNAL CIRCUIT BREAKER FOR THE EMERGENCY SOURCE.
THE PLUG AND RECEPTACLE SHALL BE PROTECTED BY THE TRANSFER
THE OPERATOR TO INITIATE THE TRANSFER.
OPERATED DESIGN. FRONT DOOR MOUNTED CONTROLS SHALL ALLOW
THE TRANSFER SWITCH SHALL BE A MANUALLY INITIATED ELECTRICALLY
BE OF A CIRCUIT BREAKER BASED DESIGN.
GENERATOR CONNECTION TO THE PUMP STATION. THE SWITCH SHALL
A MANUAL TRANSFER SWITCH SHALL BE PROVIDED FOR STANDBY
TRANSFER SWITCH:2.
PROVIEDED.
MOTOR SOFT STARTS WITH FULL BYPASS STARTERS SHALL BE
MOTOR CONTROL CENTER:1.
F15
| MN333719a_V7G-002XXX |
| MN333719a_V7ED101XXX |
| MN333719a_V7E-601XXX |
File details come from the government source that posted it. Updated .