21R0002_Plans.pdf
PDF 30 MB Posted
- Attached to
- McNary Station Services Units Upgrade Federal contract opportunity
- Solicitation number
- W912EF21R0002
About this file
This document provides details for a construction contract solicitation to upgrade McNary Station Services Units 1 and 2 at McNary Dam in Umatilla County, Oregon. The work includes replacement of stator cores and windings, new brushless exciter systems, control circuits, air coolers, and air shrouds for both units. The turbine scope of work involves disassembly, inspection and testing of components, replacement of bushing, sleeves, links, and seals, and minor repairs and painting of existing runners. The performance period is 1,000 calendar days from notice to proceed. The contract will be fixed price between $5 million and $10 million. The solicitation will be posted on August 31, 2020 with responses due as specified. The agency is the Department of the Army Corps of Engineers Walla Walla Engineering District. Security clearance is required for foreign nationals to attend an offered site visit with documentation due by email.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Site Visit 2 Attendee List.pdf | ||
| Techspec_amend0008.pdf | ||
| Amendment 0008 21R0002.pdf | ||
| Amendment 0007 21R0002.pdf | ||
| Amend 0006 21R0002.pdf | ||
| Amend 0005 21R0002.pdf | ||
| Amendment 0004 21R0002 MNA SS Unit.pdf | ||
| Amend 0003 21R002 MNA SS Unit Rehab.pdf | ||
| Site Visit Attendee List.pdf | ||
| Amendment 0002 21R0002.pdf | ||
| Amendment 0002 21R0002.pdf | ||
| Amendment 0001 21R0002.pdf | ||
| CDC and WA COVID 19 Active Screen Questionairre.pdf | ||
| 21R0002_Resource_Plans_Optimized.pdf | ||
| W912EF21R0002 MNA SS Units Upgrade.pdf | ||
| 21R0002_Resource_Plans2.pdf | ||
| 21R0002_Resource_Plans1.pdf |
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SUB -STATION
SHORE FISHWAY
WASHINGTON
RIGHT ABUTMENT
NAVIGATION LOCK
NORTH NON-OVERFLOW
P O W E R H O U S E
WITH LIGHT
CONC. PILLAR
RAMP
BOAT
RAMP
BOAT
FISH COUNTING STATION
LEFT ABUTMENT
FISHWAY
OREGON SHORE
SOUTH NON-OVERFLOW
PUMPHOUSE
FISH FACILITIES
JUVENILE
C.B.L.
DOCK
TANK
DOCK
LOADING
NO 2
WELL
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
C H
E C
K E
D B
Y
A N
S I
D
S
C O
T N
E R
S
M
IL
E S P .E
A
B O
S T
R O
M A
U G
U S
T
®of Engineers
US Army Corps ®of Engineers
US Army Corps
D R
A W
IN
G N
O
F
IL
E N
A M
E
V
IC
IN
IT
Y M
A P
S
P R
O J E
C T L
O C
A T
IO
N A
N D
G-001
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
W A
L L
A W
A L L
A D
IS
T R
IC
T
U
R B
IN
E A
N D G
E N
E R
A T
O R R
E H
A B
IL
IT
A T
IO
N
M C
N A
R Y L
O C
K A
N D D
A M
C
G
IE
R E
K
.S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
LOCATION MAP
NOT TO SCALE
LOCATION
PROJECT
N
Washtucna
Riparia
GOOSE
DAM
LITTLE
F la t
ID
A
H O
P A L O
U S E
B. N.
C. P. RR.
C r.
C r.
Alkali
E A
K
IV
E
R
SN
Cr ee kD ry
Waitsburg
R
Pomeroy
R
Flat
Union
N O
N
Cr.
As oti n
TUCAN
Camp Wooten
R
PENDLETON
WALLA WALLA
PASCO
KENNEWICK
COLFAX
GRANITE
LOWER
PULLMAN
DAM
RICHLAND
DAM
OREGON
WASHINGTON
HARBOR
ICE
CLARKSTON
YA
K
A
IM
Farrington
R
McNARY
R
IV
E R
LEWISTON
DAM
CO
U
M L
IA
B Cr
RIVER
R O
N D E
GRANDE
U M
A
TILLA
C
r. U
. P . R
R
. RIVER
B u tt e r
Elgin Wallowa
Athena
Weston
Hermiston
Anatone
Asotin
M ill
R.
WALLA
T O
U C
H E T
Touchet
Milton-Freewater
R.
Wallula
B.N.
Kahlotus
Umatilla
Plymouth
Dayton
Almota
Ferry
Starbuck
BishopCentral
MONUMENTAL
LOWER Dodge
DAM
W A
L L
A
N
SITE MAP
NOT TO SCALE
C o n s tru c tio n
'3
R I V E R
C O L U M B I A
L o c a l G rid N o rth (S o lid
C o n s tru c tio n
'3
To Plymouth
W A L L U L A L A K E
N 5,000
E ,3
,0
E ,0
N 8,000
N 225,000
N 6,000 x x x x x x x x x x x x x x x xx x x x x x x x
N 7,000 xx x x x x x
N 2,000
N 3,000
( NORTH SHORE )
W A S H I N G T O N
WALL
CONC.
x x x x x x x x x x x x x x x x xx x x x x x
Flow x x x x x xx x x x x x
OREGON
x
Access
N 3,000
3 RD
ST.
x x x x
N 2,000
S P I L L W A Y x x x
N 219,000 x x x xx x x x xx x x x
LIN
E 4
0 K V
LIN
E 3
0 K V
LIN
E 5
0 K V
TO
U
M A
TI
LL
A
U. P.
RR. (S
PUR)
x
LIN
E 1
0 K V
LIN
E 6
5 K V
LIN
E 2
0 K V
WASHINGTON
N 3,000
N 2,000 x
Flow
E ,3
,0 x
N 221,000 x x x x x
281282 xx
.4
TO UMATILLA
AREA
STORAGE
YARD
SWITCH
B.P.A.
YARD
SWITCH
B.P.A.
(SOUTH SHORE)
O R E G O N
STORAGE AREA
MCNARY LOCK AND DAM
TURBINE AND GENERATOR REHABILITATION
VICINITY MAP
NOT TO SCALE
MAP
SEE LOCATION
SPOKANE
OREGON
CLEARWATER R.
EUGENE
BOISE
P A
C
IF
IC
O
C E
A N
WASHINGTON
IDAHO
R
IV
E
REVERETT
C O
L U
M B
IA
SNAKE R.
PASCO
SEATTLE
PORTLAND
SALEM
THE
OLYMPIA
DALLES
WALLA WALLA
PENDLETON
VANCOUVER
N
M D
P -1 .0
G -0
X X
X .d g n
M D
P -1 .0
-0 -0 /1
W E
F
R
COLUMBIA RIVER, OREGON AND WASHINGTON
POWERHOUSE STATION SERVICE
O
W E
R H
O U
S E S
T A
T
IO
N S
E R
V
IC
E
C O
L U
M B
IA
R
IV
E R
O R
E G
O N A
N D W
A S
H
IN
G T
O N project documents within the scope of their employment as required by ER 1110-1-8152.
The initials or signatures and registration designations of individuals appear on these This project was designed by the Walla Walla District of the U.S. Army Corps of Engineers.
SUBMITTED BY:
SUBMITTED BY:
APPROVED BY:
WALLA WALLA DISTRICT
CHIEF OF DESIGN BRANCH
MARCUS PALMER, P.E.
WALLA WALLA DISTRICT
CHIEF OF ELECTRICAL DESIGN SECTION
JEFFREY LYON, P.E.
WALLA WALLA DISTRICT
CHIEF OF ENGINEERING & CONST DIV.
DWAYNE WESTON, P.E.
SUBMITTED BY:
SUBMITTED BY:
APPROVED BY:
HYDROELECTRIC DESIGN CENTER
CHIEF OF MECHANICAL/STRUCTURAL BRANCH
JAMES CALNON, P.E.
HYDROELECTRIC DESIGN CENTER
DIRECTOR OF
STEVEN MILES, P.E.
HYDROELECTRIC DESIGN CENTER
CHIEF OF ELECTRICAL BRANCH
JORDAN FINK, P.E.
of Engineers
US Army Corps
SOLICITATION NO.: W912EF21R0002
CONTRACT NO.:
AUGUST 2020ISSUE DATE:
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
C H
E C
K E
D B
Y
A N
S I
D
S
C O
T N
E R
S
M
IL
E S P .E
A
B O
S T
R O
M A
U G
U S
T
®of Engineers
US Army Corps
D R
A W
IN
G N
O
F
IL
E N
A M
G-002
.S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
W A
L L
A W
A L L
A D
IS
T R
R B
IN
E A
N D G
E N
E R
A T
O R R
E H
A B
IL
IT
A T
IO
N
M C
N A
R Y L
O C
K A
N D D
/0
/0
C
G
IE
R
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
M D
P -1 .0
G -0
X X
X .d g n
IN
D
E X T
O D
R A
W
IN
G
W E
F
R
M D
P -1 .0
-0 -0 /2
W E
R H
O U
S E S
T A
T
IO
N S
E R
V
IC
E
C O
L U
M B
IA
R
IV
E R
O R
E G
O N A
N D W
A S
H
IN
G T
INDEX TO DRAWINGS
GENERAL
FILE NUMBER
NO.
SHEET
TITLE
INDEX TO DRAWINGS
FILE NUMBER
NO.
SHEET
TITLE
ELECTRICAL - REMOVAL
ELECTRICAL - INSTALL
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
C H
E C
K E
D B
Y
A N
S I
D
S
C O
T N
E R
S
M
IL
E S P .E
A
B O
S T
R O
M A
U G
U S
T
®of Engineers
US Army Corps
D R
A W
IN
G N
O
F
IL
E N
A M
G-003
O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
W A
L L
A W
A L L
A D
IS
T R
R B
IN
E A
N D G
E N
E R
A T
O R R
E H
A B
IL
IT
A T
IO
N
P O
W E
R H
O U
S E S
T A
T
IO
N S
E R
V
IC
E
C O
L U
M B
IA
R
IV
E R
O R
E G
O N A
N D W
A S
H
IN
G T
O N
M C
N A
R Y L
O C
K A
N D D
G
IE
R
A R
M Y C
O R
P S O
F E
N G
IN
E E
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
M D
P -1 .0
G -0
X X
X .d g n
IN
D
E X T
O R
E S
O U
R C
E D
R A
W
IN
G
S H
E E
T
W E
F
R
M D
P -1 .0
-0
/3
TITLE TITLE
EM
WESTINGHOUSE
OLSON
PELTON
WOODWARD
KINGSBURY
SCHUTTE & KOERTING CO.
INDEX TO RESOURCE DRAWINGS INDEX TO RESOURCE DRAWINGS
GOVERNMENT
FILE NUMBER
NUMBER
SHEET
NUMBER
SHEET
FILE NUMBER
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
C H
E C
K E
D B
Y
A N
S I
D
S
C O
T N
E R
S
M
IL
E S P .E
A
B O
S T
R O
M A
U G
U S
T
®of Engineers
US Army Corps
D R
A W
IN
G N
O
F
IL
E N
A M
G-004
O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
W A
L L
A W
A L L
A D
IS
T R
R B
IN
E A
N D G
E N
E R
A T
O R R
E H
A B
IL
IT
A T
IO
N
P O
W E
R H
O U
S E S
T A
T
IO
N S
E R
V
IC
E
C O
L U
M B
IA
R
IV
E R
O R
E G
O N A
N D W
A S
H
IN
G T
O N
M C
N A
R Y L
O C
K A
N D D
G
IE
R
A R
M Y C
O R
P S O
F E
N G
IN
E E
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
M D
P -1 .0
G -0
X X
X .d g n
IN
D
E X T
O R
E S
O U
R C
E D
R A
W
IN
G
S H
E E
T
W E
F
R
M D
P -1 .0
-0
/4
TITLE
INDEX TO RESOURCE DRAWINGS INDEX TO RESOURCE DRAWINGS
AMERICAN GOVERNOR
FILE NUMBER
NUMBER
SHEET
NUMBER
SHEET
FILE NUMBERMCNARY IN HOUSE
40 CUBIC YARD DUMPSTERS.
TOOL TRAILER, AND MAXIMUM (2)
GRAVEL LOT AVAILABLE FOR OFFICE TRAILER,
CONTRACTOR STAGING AREA -
PARKING LOT
TAILRACE ENTRANCE GATE
SECURITY GUARD SHACK
JUVENILE FISH FACILITY
SHORELINE
OREGON SHORE ADULT FISHWAY
PARKING LOT
TAILRACE ENTRANCE GATE
SECURITY GUARD SHACK
JUVENILE FISH FACILITY
SHORELINE
OREGON SHORE ADULT FISHWAY
40 CUBIC YARD DUMPSTERS.
TOOL TRAILER, AND MAXIMUM (2)
GRAVEL LOT AVAILABLE FOR OFFICE TRAILER,
CONTRACTOR STAGING AREA -
PARKING LOT
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
C H
E C
K E
D B
Y
A N
S I
D
S
C O
T N
E R
S
M
IL
E S P .E
A
B O
S T
R O
M A
U G
U S
T
®of Engineers
US Army Corps ®of Engineers
US Army Corps
D R
A W
IN
G N
O
F
IL
E N
A M
E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
W A
L L
A W
A L L
A D
IS
T R
R B
IN
E A
N D G
E N
E R
A T
O R R
E H
A B
IL
IT
A T
IO
N
P O
W E
R H
O U
S E S
T A
T
IO
N S
E R
V
IC
E
C O
L U
M B
IA
R
IV
E R
O R
E G
O N A
N D W
A S
H
IN
G T
O N
M C
N A
R Y L
O C
K A
N D D
P -1 .0
G -0
X X
X .d g n
/0
/0
C
G
IE
R E
K
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
G-005
TO WAREHOUSE
TO HIGHWAY
BOAT RESTRICTION ZONE
POWERHOUSE
TAILRACE
SOUTH NON-OVERFLOW
SCALE: NTS
S T
A G
IN
G A
R E
A S
CONTRACTOR ACCESS AND STAGING AREAS
S T
R
D
TO WAREHOUSE
TO HIGHWAY
BOAT RESTRICTION ZONE
POWERHOUSE
TAILRACE
SOUTH NON-OVERFLOW
X
X
X x x x x x x x x x x x
X
X
X x x x x x x x x x x x
SUPPLY PIPE
34" DIA. WATER
EXISTING
F I
S H
C O
U N
T I
N G
S T
A T I
O N xx
G E
N E
R A
L S
IT
E P
L A
N
C O
N T
R A
C T
O R A
C C
E S
S A
N D
F L
O W
F L
O W
PLAN
NORTH
W E
F
R
M D
P -1 .0
-0 -0 /5
A5
IF USED
CUBICLE NO.
OR BLANK FOR BRANCH CKTS.
UTILIZATION EQ. DESIGNATION
UTILIZATION EQUIPMENT
CIRCUIT NO. TO THE
DESIGNATION
SOURCE EQUIP.
CUBICLE NO. IF USED
VOLTAGE OR USAGE CODE:
IDENTIFICATION LETTER
SECTION OR DETAIL
THE SECTION OR DETAIL IS TAKEN)
APPEARS ON THE SAME SHEET WHERE
LEFT BLANK, THE SECTION OR DETAIL
(IF BOTTOM HALF OF SYMBOL IS
SECTION OR DETAIL IS DRAWN
SHEET NUMBER ON WHICH
TERMINAL BLOCK
WIRE LABEL
CONTROL BOARD DESIGNATION
DEVICE/TERMINAL BLOCKDEVICE/TERMINAL BLOCK
DEVICE/TB TERMINAL LABEL WIRE LABEL
CUBICLE NUMBER
DEVICE/TB TERMINAL LABEL
IDENTIFICATION LETTER
SECTION OR DETAIL
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
C H
E C
K E
D B
Y
A N
S I
D
S
C O
T N
E R
S
M
IL
E S P .E
A
B O
S T
R O
M A
U G
U S
T
®of Engineers
US Army Corps ®of Engineers
US Army Corps
D R
A W
IN
G N
O
F
IL
E N
A M
E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
W A
L L
A W
A L L
A D
IS
T R
R B
IN
E A
N D G
E N
E R
A T
O R R
E H
A B
IL
IT
A T
IO
N
P O
W E
R H
O U
S E S
T A
T
IO
N S
E R
V
IC
E
C O
L U
M B
IA
R
IV
E R
O R
E G
O N A
N D W
A S
H
IN
G T
O N
M C
N A
R Y L
O C
K A
N D D
P -1 .0
G -0
X X
X .d
G
IE
R E
K
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T
G-006
5. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS.
THE CONDUIT AND CABLE SCHED., SIZED PER NEC TABLE 250-122.
CIRCUITS WHETHER OF NOT SHOWN ON THE DRAWINGS OR IN
AND SHALL BE PROVIDED IN ALL NEW FEEDERS AND BRANCH
TO REDUCE DRAWING CLUTTER FOR CLARITY, BUT ARE REQ.
4. EQUIPMENT GROUNDING CONDUCTORS MAY NOT BE SHOWN
THE INFORMATION ON THE INDIVIDUAL DRAWING SHALL GOVERN.
ON AN INDIVIDUAL DRAWING AND DIFFERS FROM THIS DRAWING,
FOR ALL DNGS. HOWEVER, IF SYMBOLS AND LEGEND APPEAR
3. SYMBOLS AND LEGEND SHOWN ON THE DNG ARE APPLICABLE
VALUE.
QUANTITIES TO WHICH THEY RESPOND ARE OF THE LOWEST
WITH CONTACTS IN THE DE-ENERGIZED POSITION OR WHEN
2. CONTROL DIAGRAMS SHOW CONTROL AND XFER SWITCHES
REFERENCED ON THE FOLLOWING INDIVIDUAL DRAWINGS.
1. ITEMS SHOWN ON THIS DRAWING ARE NOT ALL NECESSARILY
WIRE LABELING EXAMPLES
CIRCUIT DESIGNATIONS
WIRE COLOR TABLE
H
A
V
W
F
S
L
200:5
480-120
TB
AS
VS
I R
SS
SP
OR
L-0
L-0
SECTION
VIEW
SB1()-e1-SU1()
K
VOLTAGE XFMR
INSTRUMENTATION
SPARE
120 OR 208VAC
480VAC
120V PREFERRED AC
250VDC
125VDC
CONTROL
CURRENT XFMR
v u s r q h f e c a
SYNCHRONIZING LAMPS
SYNCHROSCOPE
FREQUENCY METER
AMMETER
WATT METER
VOLT METER
WIRE CROSSING (NOT CONNECTED)
WIRE CONNECTED
CONDUIT TURNED TOWARD OBSERVER (PLANS, DETAILS, ELEVATIONS)
CONDUIT TURNED AWAY FROM OBSERVER (PLANS, DETAILS, ELEVATIONS)
CONDUIT/CABLE (PLANS, DETAILS, ELEVATIONS)
CONDUIT EMBEDDED IN FLOOR, WALL OR UNDERGROUND
ELEVATIONS)
CONDUIT EXPOSED, CABLE OR BUS (PLANS, DETAILS,
OUTPUT - SOLID-STATE ELEMENT OR DEVICE
INPUT - SOLID-STATE ELEMENT OR DEVICE
HYDROGEN DENSITY MONITOR
CONDUIT TERMINATION AT CABLE TRAY (PLANS, DETAILS, ELEVATIONS)
TO CONTROL DEVICE NUMBER
RELAY, FUNCTION ACCORDING
BROWN26
YELLOW
BLACK
BLUE
COLOR
BACKGROUND OR BASE
BLACK
RED
BLACK27
REDBLACK
BROWN6
BLUEBLACK
COLOR
TRACER
NUMBER
CONDUCTOR
BLUE
RED
RED16
RED
YELLOW
ORANGE
BROWN
BLUE
RED
BROWN
YELLOW
ORANGE
BROWN
YELLOW
ORANGE
BROWN
YELLOW
BLUE
RED
ORANGE
BLUE
RED
YELLOW
ORANGE
BROWN
BLACK
BLACK
BLACK
ORANGE RED
BLACK
BLUE
ORANGE
BLACK
BLUE
RED
BROWN
YELLOW
ORANGE
BROWN
YELLOW
ORANGE
BROWN
YELLOW
ORANGE
BLUE
BROWN
YELLOW
BLUE
BLUE
RED
COLOR
TRACER
NUMBER
CONDUCTOR
ORANGE4
YELLOW5
COLOR
BACKGROUND OR BASE
BLACK
---2
M
SYNCHRONIZING SWITCH (I=INCOMING, R=RUNNING)
DRAWOUT CIRCUIT BREAKER
SPARE WIRE(S)
DISCONNECTING DEVICE, DISCONNECTING CONTACT
AMMETER SWITCH
VOLTMETER SWITCH
DRAWOUT CIRCUIT BREAKER WITH INTERLOCKS
RESISTOR OR SHUNT TRIP ELEMENT
AIR CIRCUIT BREAKER
AND VOLTAGES AS SHOWN
POTENTIAL OR CONTROL TRANSFORMERS, NUMBER
RATIO AS SHOWN
CURRENT TRANSFORMERS, NUMBER AND CURRENT
EQUIPMENT ENCLOSURE
115kV SWITCHYARD CIRCUIT BREAKER
DISCONNECT SWITCH
SWITCHYARD MOTOR OPERATED
RESISTOR
SURGE CAPACITOR
SURGE ARRESTER
DISCONNECT SWITCH
POWER TRANSFORMER (ONE LINE DIAGRAM)
TRANSFORMER (CONTROL DIAGRAM)
TEST BLOCK
FUSE
CONTACTS (NORMALLY OPEN)
CONNECTION TO GROUND BUS
CONTACTS (NORMALLY CLOSED)
BREAKER MECHANICAL INTERLOCK
SWITCH
2-POSITION SELECTOR SWITCH OR TRANSFER
INVERTER OR RECTIFIER
A=AMBER
INDICATING LIGHT: R=RED, G=GREEN, W=WHITE,
BREAKER KEYED INTERLOCK
DIRECTION OF KEY TRANSFER
DEVICE OPEN. (WITH KEY HELD)
KEY INTERLOCK USED TO LOCK
DEVICE OPEN. (WITH KEY REMOVED)
KEY INTERLOCK USED TO LOCK
NOTES:
GRAPHIC SYMBOLS LEGEND (CONT.)GRAPHIC SYMBOLS LEGEND
E L E
C T
R
IC
A L G
E N
E R
A L N
O T
E S L
E G
E N
D
L32
A9A
A7A
A9A
A7A
WIRE MARKERSTB OR DEVICE
WIRE ID
SB
HD
TP
SHORT CIRCUIT TERMINAL BLOCK
HEAVY DUTY TERMINAL BLOCK
THYRITE PROTECTOR
SHOP TO LEAVE WIRES LONG ENOUGH TO REACH
ANY POINT ON SHORT CIRCUIT TERMINAL BLOCK
WIRE
CONNECTION
MADE
WIRE
CONNECTION
NOT MADE
CUSTOMER
CONNECTION CUSTOMER
CONDUIT
P
CURRENT AND VOLTAGE TRANSFORMER SYMBOLS
SHOW TERMINALS OF THE SAME INSTANTANEOUS
POLARITY AS INDICATED AT THE RIGHT.
PULL FUSE
POINTS
ALL PROGRAMMABLE CONTACTS IN CLOSE & TRIP CIRCUITS
TO BE PROGRAMMED BY CUSTOMER.
TERMINAL BLOCK
CONNECTION
1T01
WHEN CONNECTING TO REMOTE EQUIPMENT.
CAUTION: CUSTOMER TO REMOVE JUMPERS
R G
5 STOP DEVICE (EMERG)
20 ELECTRICALLY OPERATED VALVE
39 FIELD REDUCING CONTACTOR
41 FIELD CONTACTOR
45 D-C OVERVOLTAGE RELAY
53 EXCITER RELAY
59X A-C OVERVOLTAGE AUX RELAY
62W TIME DELAY CLOSING RELAY
63 FLUID PRESSURE, LEVEL OR FLOW RELAY
65 GOVERNOR
70 MOTOR OPERATED RHEOSTAT
86G GENERATOR LOCKOUT RELAY
87GX GENERATOR DIFFERENTIAL AUX RELAY
90 VOLTAGE REGULATOR
A ALTERNATING CURRENT, AMBER, AMMETER,AIR
B BRAKE
C
G GENERATOR, GREEN OR GATE
L LOW, LOWER OR LIMIT
M MOTOR OR MANUAL
N NEGATIVE , NORMAL OR NEUTRAL
P POSITIVE
Q OIL OR QUICK
R
(S) DEVICE LOCATED ON STRUCTURE
T TRIP, TRANSFORMER, TIME OR TRANSMITTER
U UPPER
V VOLTMETER
W WATER OR WHITE
X-Y AUXILIARY RELAY
(AO2) DEVICES LOCATED IN ACTUATOR CABINET
(A02.1) DEVICES LOCATED IN DIGITAL GOVERNOR CABINET
CC CLOSING COIL
CL CLUTCH
CO2 CARBON DIOXIDE EQUIPMENT
CS CONTROL SWITCH
IND INDICATING
LS LIMIT SWITCH
MAN MANUAL
MOC MECHANISM OPERATED CONTACT
NH NORMAL ANTI-HUNTING DEVICE
NL NORMAL LOWER
NR NORMAL RAISE
QL QUICK LOWER
QR QUICK RAISE
QH QUICK ANTI-HUNTING DEVICE
REG REGULATING
RES RESITOR
RHEO RHEOSTAT
SI SEAL-IN COIL
SL SPEED LOWER
SR SPEED RAISE
SSG SPEED SIGNAL GENERATOR
TC TRIP COIL
TD TIME DELAY
TS REGULATOR TRANSFER SWITCH
VL VOLTAGE LOWER
VR VOLTAGE RAISE OR VOLTAGE ADJUSTING RHEOSTAT
DETAILS, ELEVATIONS)
OR TURNED AWAY FROM OBSERVER (PLANS,
NON-SEGREGATED PHASE BUS TURNED TOWARDS
SECTION
VIEW
SCALE:
SECTION NAME
NN
PRO2/LA-A1X (SO7)PRO2/DA-91
WIRE LABELWIRE LABEL
LABEL
BLOCK
TERMINAL
(SEE SPECIFICATIONS)
PCC5/AQ-1(S5)PCC5PCC5/BB-7(A5)
SECTION SYMBOLS
NOMENCLATURE
SX EXCITER CUBICLE
STATION SERVICE SWITCHBOARD ON GEN FLOORSO
SPO
SC CONTROL ROOM SWITCHBOARDS
5KV SWITCHBOARD ON GENERATOR FLOOR
MR
MV
MOTOR OPERATED RHEOSTAT
MANUAL VOLTAGE ADJUST
E
CLOSE, COIL, COMPLETE
LC
GEN. OPERATION SELECTOR SWITCH (MAN./AUTO, LOC./REM.)
64 GROUND PROTECTIVE RELAY
F GENERATOR FIELD
FV
FA FIELD CURRENT
FIELD VOLTAGE
DACS DATA ACQUISITION AND CONTROL SYSTEM
XDCR TRANSDUCER
52 AC CIRCUIT BREAKER
CONTROL TRANSFER
EXCITATION
MASTER ELEMENT
RED, RAISE, RHEOSTAT, RECEIVER, REGULATOR
W E
F
R
M D
P -1 .0
-0
/6
ED201
UO2 UO1
SO2C
RTUO1
RTUO2
SO BOARD
DN
INVERTER
SUO/SRO
SWBD
DN
SHAFT
PIPE
OPENING IN CEILING ABOVE
MAIN UNITS
HATCH
EQUIPMENT
PIER 1
TURBINE FLOOR EL. 267.5
EL
B
ED202
A
ED201
L C
(SX02)
CABINET
EXCITER
U02
(SX01)
CABINET
EXCITER
U01
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
C H
E C
K E
D B
Y
A N
S I
D
S
C O
T N
E R
S
M
IL
E S P .E
A
B O
S T
R O
M A
U G
U S
T
UNIT
P-4 P-3 P-2P-7 P-6 P-5
UNIT
P-1
ASSEMBLY
P-8 A-2 A-1P-15
HOUSE
PUMP-
FISH
P-11 P-10 P-9P-14 P-13 P-12
UNIT
UNIT
UNIT
UNIT
STATION
UNITUNIT
BAY
SERVICE
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
BAY
®of Engineers
US Army Corps ®of Engineers
US Army Corps
D R
A W
IN
G N
O
F
IL
E N
A M
E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
W A
L L
A W
A L L
A D
IS
T R
R B
IN
E A
N D G
E N
E R
A T
O R R
E H
A B
IL
IT
A T
IO
N
P O
W E
R H
O U
S E S
T A
T
IO
N S
E R
V
IC
E
C O
L U
M B
IA
R
IV
E R
O R
E G
O N A
N D W
A S
H
IN
G T
O N
M C
N A
R Y L
O C
K A
N D D
P -1 .0
E
D
X X
X .d
G
IE
R E
K
R E
M O
V A
L P
O R
T L
A N
D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
NOTES:
RESOURCE DRAWINGS
SCALE: NTS
ED101
E X
C
IT
E R P
L A
N V
IE
W A
N D E
L E
V A
T
IO
N
F L
O
W PLAN
NORTH
KEY PLAN
CONDUCTORS TO EXCITER.
4. REUSE EXISTING EMBEDDED CONDUITS TO ROUTE NEW
HOLES IN THE SO BOARD.
AND METERING. CONTRACTOR SHALL ALSO PACTH ALL UNUSED
RELAYS, TEST BLOCKS, CONTROL SWITCHES, INDICATOR LIGHTS,
MODIFICATIONS INCLUDING, BUT NOT LIMITED TO, THE ADDTION OF
3. CONTRACTOR SHALL MODIFY THE SO BOARD, AS SHOWN ON
SUPPORTS.
ROUTING AROUND EXISTING STRUCTURES, EQUIPMENT, AND
2. CONTRACTOR SHALL FIELD VERIFY CONDUIT AND CABLE
1. ITEMS IN BOLD INDICATE EQUIPMENT TO BE REMOVED.
STATION SERVICE BAY PLAN EL 267.5
PLAN
NORTH
A3 8'4'0'
W E
F
R
M D
P -1 .0
-6 -1
D
/1
PLAN EL 267.5 STATION SERVICE BAY HRG INSTALLATIONMDP-1.46-6-1D40/2
DRAWING NUMBER TITLE
SCALE: 3/16" = 1'-0"
V S V
F FS
PANEL
SWINGING
TRAYS
CABLE
TO MEET
CHIMNEY
17 55
GENERATOR 01
ENTRANCE FROM CEILING
TYPICAL CONDUIT
SO1 SO2 SO3 SO4 SO5 SO6 SO7 SO8 SO9 SO10
17 55
INC. RUN
CABLE AREA
REGULATOR 01 GENERATOR 02 REGULATOR 02
ANN (26)
S J .1
S J .1
SP01 / SPO2
XJ341
XJ342
XJ941
XJ942
HMI
SPO1
XPO122
XPO232
XPO132
XPO212
XPO131
XPO211XPO222
TO1, TO2 & SJ SWITCHGEAR
SPO2
ANN (26)
ANN (26)
ANN (26)
AMPERES
SPO1
ZJO2
XPO112
UO1
XPO211
NAVLOCK FDR 2
XPO212
UNW PUMP FDR 2
XPO232
BPA SUB FDR 2
ZJO1
XPO112
UO1
A-C
AMPERES
A-C
AMPERES
A-C
AMPERES
A-CA-C
AMPERES
A-C
AMPERES
C
B
A
C
B
A
HMI
SQOC
43 SPO1
(SO2C)
43 SPO1
(SO2C)
2" 2'-3 15/16 " 2'-3 15/16 " 2'-3 15/16 " 1'-7 15/16 " 2'-3 15/16 " 2'-3 15/16 " 2'-3 15/16 " 2'-3 15/16 " 2'-3 15/16 " 4'-7 7/8 " 2"
/8
SPO1
SPO1 BUS
TO1
BUS VOLTAGE
XPO222
SPO2 BUS
UO2
UO2
SPO2
BUS VOLTAGE
SPO2
BPA SUB FDR 1
XPO132
NAVLOCK FDR 1
XPO122
UNW PUMP FDR 1
XPO131
1'-5 1/2 "1 /1
XPO112
TO2
FDR 1
SP01
XJ341
FDR 1
SP02
XJ342
FDR 2
SP02
XJ942
FDR 2
SP01
XJ941
166665
63109
72 73
1 5
74 75
9 10 63
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
C H
E C
K E
D B
Y
A N
S I
D
S
C O
T N
E R
S
M
IL
E S P .E
A
B O
S T
R O
M A
U G
U S
T
A-C
AMPERES
A-C A-C
KILOVARS
D-C
AMPERES
D-C
AMPERES
D-C D-C
VOLTS MEGAWATTS
VOLTS VOLTS
0 600 50000 0 2500
4000 0 0 150015020
5 2500
A-C
AMPERES
A-C A-C
KILOVARS
D-C
AMPERES
D-C
AMPERES
D-C D-C
VOLTS MEGAWATTS
VOLTS VOLTS
0 600 50000 0 2500
4000 0 0 150015020
5 2500
IND. R
E G
M
A N
U
A L
REG. TRNSFR
R A
IS
E
VOLT ADJ RHEO
LO
W
E R R
A
IS
E
LO
W E R
EX FLD RHEO
C
LO
S
E
FLD BKR
T R
IP
C
LO
S E
FLD BKR
T
R
IP
IND. R
E G
M A N
U A L
REG. TRNSFR
R
A
IS
E
VOLT ADJ RHEO
LO
W E R R
A
IS
E
LO
W
E R
EX FLD RHEO
G R G R
G R G RG W R G W R
G R G R
C
LO
S E
FLD BKR
T R
IP
IND. R
E G
M A N
U A L
REG. TRNSFR
R A
IS
E
VOLT ADJ RHEO
LO
W E R R
A
IS
E
LO
W E R
EX FLD RHEO
G R G R G W R
RED = CLOSED
GREEN = OPEN
12. FIELD BREAKER CONTROL
DEV #90TS
9. REGULATOR TRANSFER
RED = UPPER LIMIT
GREEN = LOWER LIMIT
10. VOLT ADJUST RHEO CONTROL
RED = UPPER LIMIT
WHITE = NORMAL
GREEN = LOWER LIMIT
63 EXC FIELD RHEO CONTROL
®of Engineers
US Army Corps ®of Engineers
US Army Corps
D R
A W
IN
G N
O
F
IL
E N
A M
E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
W A
L L
A W
A L L
A D
IS
T R
R B
IN
E A
N D G
E N
E R
A T
O R R
E H
A B
IL
IT
A T
IO
N
M C
N A
R Y L
O C
K A
N D D
P -1 .0
E
D
X X
X .d g n
ED201
C
G
IE
R E
K
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
NOTES:
S T
A T
IO
N S
E R
V
IC
E S
O S
W
IT
C H
B O
A
M O
V
L
FRONT ELEVATION - SWITCHES
SCALE: 6" = 1'-0"
LEGEND:
63. VOLTAGE ADJUSTING CONTROL SW.
12. FIELD BREAKER CONTROL SWITCH
10. RHEOSTAT CONTROL SWITCH
9. REGULATOR TRANSFER SWITCH, DEV.#90TS
5. 3-CKT VOLTMETER SWITCH
1. AMMETER SWITCH
67. SO2C HMI (GFE)
66. LOCKOUT RELAY, DEV.#86T
65. THREE PHASE VOLTMETER
64. AMMETER
55. AUX. GEN. DIF. RELAY, DEV.#87GX
27. ANNUNCIATOR SWITCH
26. ANNUNCIATOR
22. SYNC PANEL SELECTOR SWITCH
17. LOCKING OUT RELAY, DEV.#86G
16. PLC LOCAL CONTROL SELECTOR SWITCH, DEV.#43
15. EMERGENCY STOP SWITCH, DEV.#5
11. OVERSPEED AUX RELAY RESET SWITCH, DEV.#12X
8. CONTROL SWITCH FOR BREAKER
7. CURRENT TEST DEVICE
6. POTENTIAL TEST DEVICE
4. AUTO-RUN SWITCH DEV.#1
3. MANUAL AUTOMATIC SELECTOR SWITCH, DEV.#43
2. SYNCHROSCOPE SWITCH
76. VOLTAGE REGULATOR
75. PILOT EXCITER VOLTAGE
74. GENERATOR FIELD VOLTAGE
73. EXCITER FIELD AMETER
72. GENERATOR FIELD AMETER
71. GENERATOR VARMETER
70. GENERATOR WATTMETER
69. GENERATOR VOLTMETER
68. GENERATOR AMETER
LEGEND:
RESOURCE DRAWINGS:
FRONT ELEVATION - SO STATION SERVICE SWITCHBOARD
C4
2'1'0'
4"2"0"
W E
F
R
M D
P -1 .0
-6 -1
D
W E
R H
O U
S E S
T A
T
IO
N S
E R
V
IC
E
C O
L U
M B
IA
R
IV
E R
O R
E G
O N A
N D W
A S
H
IN
G T
ED201
SCALE: 1" = 1'-0"
INST SHT 1 RO
STATION SERVICE SWBD SO E-202-SK-V2-250 2. ALL HOLES IN PANELS TO BE PATCHED AND PAINTED ANSI-61 GRAY.
1. ITEMS IN BOLD INDICATE EQUIPMENT TO BE REMOVED. DRAWING NUMBER TITLE
2"
XP0131
SEL
WHM
XP0132
SEL
WHM
XP0122
SEL
WHM
FT1 FT1 FT1
FT1FT1FT1
FT1 FT1 FT1
FT1FT1FT1
FT1 FT1 FT1
FT1FT1FT1
FT1 FT1 FT1
FT1FT1FT1
FT1 FT1 FT1
FT1FT1FT1
FT1
FT1 FT1 FT1
FT1FT1FT1
FT1
FT1
FT1FT1
FT1FT1FT1FT1 FT1 FT1
FT1FT1
4'-7 7/8 " 2'-3 15/16 " 2'-3 15/16 " 2'-3 15/16 " 2'-4" 2'-3 15/16 " 1'-7 15/16 " 2'-3 15/16 " 2'-3 15/16 " 2'-3 15/16 " 2"
/8
XP0211
SEL
WHM
XP0212
SEL
WHM
XP0232
SEL
WHM
T02
11T
SEL
WHM
700G
U02
11G
T01
11T
700G
U01
11G
SEL
WHM
700G
SEL
SYNC
CHK
SYNC
(13X)
(38X)
(12X)
(63QX)
(4)
(63QX)
(12X)
(38X)
(13X)
(4)
700G
SEL
SYNC
CHK
SYNC
SOR10 SOR1SOR2SOR3SOR4SOR5SOR6SOR7SOR8SOR9
FT1
61 60
63 64
63 64
61 60
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
C H
E C
K E
D B
Y
A N
S I
D
S
C O
T N
E R
S
M
IL
E S P .E
A
B O
S T
R O
M A
U G
U S
T
(53)
(53)
®of Engineers
US Army Corps ®of Engineers
US Army Corps
D R
A W
IN
G N
O
F
IL
E N
A M
E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
W A
L L
A W
A L L
A D
IS
T R
R B
IN
E A
N D G
E N
E R
A T
O R R
E H
A B
IL
IT
A T
IO
N
P O
W E
R H
O U
S E S
T A
T
IO
N S
E R
V
IC
E
C O
L U
M B
IA
R
IV
E R
O R
E G
O N A
N D W
A S
H
IN
G T
O N
M C
N A
R Y L
O C
K A
N D D
P -1 .0
E
D
X X
X .d g n
R E
M O
V A
L
ED202
C
G
IE
R E
K
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
NOTES:
39. EXCITER RELAY
66. UO1/UO2 11G GENERATOR PROTECTION RELAY (SEL 700G)
65. UO1/UO2 WATT-HOUR METER
64. UO1/UO2 25A SYNC RELAY (SEL 700G)
63. U01/UO2 25CK SYNC CHECK RELAY (SEL 751)
62. TO1/TO2 11T TRANSFORMER DIFFERENTIAL PROTECTION RELAY (SEL 787)
61. FT1 TEST SWITCH, 10 POTENTIAL
60. FT1 TEST SWITCH, 6 CURRENT AND 4 POTENTIAL
59. SPO1/SPO2 FEEDER BREAKER WATT-HOUR METER
58. GENERATOR MASTER RELAY
45. SYN SPEED AUXILIARY RELAY
38. AUX GOV OIL PRESSURE RELAY
37. AUXILIARY BEARING THERMAL RELAY
35. AUXILIARY TURBINE OVERSPEED RELAY
S T
A T
IO
N S
E R
V
IC
E S
O S
W
IT
C H
B O
A R
D
R E
A R
RESOURCE DRAWINGS:
REAR ELEVATION - SO STATION SERVICE SWITCHBOARD
C4
2'1'0'
W E
F
R
M D
P -1 .0
-6 -1
D
STATION SERVICE SWBD SO INST. SHT.2 R1E-203-SK-V2-251
2. ALL HOLES IN THE FRAME TO BE PATCHED AND PAINTED ANSI-61 GRAY.
1. ITEMS IN BOLD INDICATE EQUIPMENT TO BE REMOVED.
SCALE: 1" = 1'-0"
ANN
UNIT 02
1 3 1 3
CONTROL PANEL
STA. SERVICE
SC10 (SOC)
02 01
SPO2
SPO1
XJ941 XJ341
XJ342XJ942
SJ9.1 SJ3.1
UNIT 01
TACHTACH
TEST BLOCKS
SC1 - SC9 SC11
EMER. SHUT DOWN
EMER. SHUT DOWN
OFF
S T O P
S T O P
OFF
S T O P
S T O P
EMER. SHUT DOWN
9. EMERGENCY STOP
OFF
S T O P
S T O P
9 9
8 8 8
31 32
5 6
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
C H
E C
K E
D B
Y
A N
S I
D
S
C O
T N
E R
S
M
IL
E S P .E
A
B O
S T
R O
M A
U G
U S
T
R A
IS
E
LO
W E R
VOLT ADJ RHEO
R A
IS
E
LO
W E R
VOLT ADJ RHEO
R A
IS
E
LO
W E R
EX FLD RHEO
R A
IS
E
LO
W E R
EX FLD RHEO
A-C
AMPERES
A-C
A-C
KILOVARS
VOLTS
MEGAWATTS
0 600 50000
0 25005 2500
A-C
AMPERES
A-C
A-C
KILOVARS
VOLTS
MEGAWATTS
0 600 50000
0 25005 2500
WGRWWGRW RWGRWG
R A
IS
E
LO
W E R
EX FLD RHEO
R A
IS
E
LO
W E R
VOLT ADJ RHEO
RWGWGRW
WHITE = LOWER
GREEN = LOWER LIMIT
RED = UPPER LIMIT
WHITE = RAISE
(FROM LEFT TO RIGHT)
5. VOLTAGE ADJUSTING RHEOSTAT CONTROL
RED = UPPER LIMIT
WHITE = NORMAL
GREEN = LOWER LIMIT
6. EXCITER FIELD RHEOSTAT CONTROL
®of Engineers
US Army Corps ®of Engineers
US Army Corps
D R
A W
IN
G N
O
F
IL
E N
A M
E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
W A
L L
A W
A L L
A D
IS
T R
R B
IN
E A
N D G
E N
E R
A T
O R R
E H
A B
IL
IT
A T
IO
N
P O
W E
R H
O U
S E S
T A
T
IO
N S
E R
V
IC
E
C O
L U
M B
IA
R
IV
E R
O R
E G
O N A
N D W
A S
H
IN
G T
O N
M C
N A
R Y L
O C
K A
N D D
P -1 .0
E
D
X X
X .d g n
ED205
C
G
IE
R E
K
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
NOTES:
R E
M O
V
34. GENERATOR VARMETER
33. GENERATOR WATTMETER
32. GENERATOR VOLTMETER
31. GENERATOR AMMETER
6. EXCITER FIELD RHEOSTAT CONTROL SWITCH
5. VOLTAGE ADJUSTING RHEOSTAT CONTROL SWITCH
N T
R O
L R
O O
M S
C S
W
IT
C H
B O
A
FRONT VIEW - SWITCHES
SCALE: NTS
TACH-TACHOMETER
S.A.-SPEED LEVEL ADJUSTMENT INDICATOR
30. PLC LOCAL CONTROL SELECTOR SWITCH
29. GEN DROP LOCKOUT RELAYS
28. GEN DROP UNIT SELECT SWITCHES
27. GOVERNOR BY-PASS VALVE CONTROL SWITCH
26. AUTO FREQ. CONTROL TRIP-RESET SWITCH
25. BRAKE INDICATING LIGHTS
22. UNIT BREAKAWAY LIGHT
21. UNIT START SWITCH
20. EXCITER SYSTEM VOLTS 500-0-500 ZERO CENTER
AUTO RUN SWITCH19.
17. AUTOMATIC SYNCHRONIZER
16. EMERGENCY FREQUENCY METER SWITCH
15. REGULATOR TRANSFER INDICATING LIGHTS
14. FIELD BREAKER CONTROL SWITCH
13. ANNUNCIATOR SWITCH
12. UNIT OPERATION SELECTOR SWITCH
11. LOCAL CENTRAL CONTROL INDICATING LIGHTS
10. AUTOMATIC SYNCHRONIZING SWITCH
9. EMERGENCY STOP SWITCH
8. BREAKER CONTROL SWITCH
7. GOVERNOR MOTOR RESPONSE RHEOSTAT
4. VOLTAGE REGULATOR CONTROL SWITCH
3. GATE LIMIT CONTROL SWITCH
2. SYNCHRONIZING SWITCH
1. SPEED CONTROL SWITCH
RESOURCE DRAWINGS:
FRONT VIEW PANELS- SC SWITCHBOARD
W E
F
R
M D
P -1 .0
-6 -1
A
A3
ED205
STATION SERVICE SWBD SO INST. SHT.2 R1E-203-SK-V2-251
2. ALL HOLES IN THE FRAME TO BE PATCHED AND PAINTED ANSI-61 GRAY.
1. ITEMS IN BOLD INDICATE EQUIPMENT TO BE REMOVED.
ALL SJ3.1 & SJ9.1 CTS ARE STANDARD AMRAN #CT102
200:5
T5
FT2
FT1
T2
11F 11F11F 11F 11F11F11F11F 11F 11F11F 11F 11F11F 11F 11F 11F 11F 11F 11F 11F11F
11F11F 11F
11F 11F
11F11F 11F 11F 11F 11F
WHM WHMWHM WHM WHM WHM WHM WHM WHM WHM WHM WHM
WHM
WHM
WHM WHMWHM WHM WHM WHM WHM WHM WHM WHM WHM WHM WHMWHM
WHM WHM WHM
11F11F 11F
WHM WHM WHM
WHM
WHM
ARRESTOR
SURGE
SERVICE
NEW STATION
ARRESTOR
SURGE
SERVICE
NEW STATION
BUS PT
FROM SPO2
METERING &
SYNC EQPT
& SYNC EQPT
TO METERING
& SYNC EQPT
TO METERING
FROM SPO1
BUS PT
TO 11T-TO2
TO METERING
& SYNC EQPT
ZJJFF
MANUAL
TRANSFER
F T
J F F
FACILITY
TO SPO2
BUS PT
SWITCH FOR
JUVENILE
FISH
AMAM
TO2
AM AMAMVM
11T
TIE
AM
11B
SJ3.1
11B
SJ9.1
AM
U-O2
WT
WT
11G
UO2
25A
U02
UO1
TO1
11T
VM
U-O1 25A
U01
11G
AMAMAM AM
AM
AM
AM
AMAM AMAM AM AMAMAM
AM AMAMAM AM
WHMAMWHM
AMAMAMAM AM AMAMAM
200:5 200:5
1200:51200:5 1200:51200:5
200:5
1200:5
200:5
1200:5
200:5 1200:5
1200:51200:5 1200:51200:5 1200:5
200:5200:5
1200:5
200:5 *600:5 *400:5200:5 *600:5
1200:51200:5 1200:51200:5 1200:51200:5 1200:51200:5
F S
P
*600:5 *400:5200:5 *600:5 200:5 200:5200:5 200:5
B U
S
1200:5 B
U S
F S
P
200:5200:5
1200:5
200:5
C200
X P
O
(*)2000:5
200:5 4200:120V200:5
ZJO1.1ZJO1.2
X P
O
SPO1
(*)2000:5
C200
(*)2000:5
C200
(3)
ZJO2.1ZJO2.2
600:5
UNW PUMP FDR NO.1
NAV LOCK FDR NO.1
BPA SUB FDR NO.1
600:5
1200:5
200:5
1200:5
SJ3.1 BUS 2SJ3.1 BUS 1
1200:5
SJ9.1 BUS 1
200:5 200:5200:5 200:5
200:5 200:5
200:5 200:5
1200:5
4200:120V
(3)
5000KVA
4.16KV
X P
O
X P
O
HRG
R E
S
1200:5
200:5
1200:5 1200:5
TO1
13.8KV
200:5 200:5
X J
X J
X J 2X
J
X J
X J
X J
X J 2 X J
X J
X J 2 X
J
X J
X J
X J
X J
X J
S Q
O F
D R
S Q
F
D R
S Q
F
D R
S Q
F
D R
S P
A R
E
S Q
F
D R
S Q
O F
D R
S Q
F
D R
X J
X J
X J
X J
S Q
F
D R
S Q
F
D R
X J
S P
A R
E
C L
R
FT2
U-3
X J
LINE 2
T5
FT1
LINE 5
X J
U-9U-10 U-4
X J
X J
C L
R
T2
X J
X J
X J
X J
X J
X J
X J
X J
5000KVA
4.16KV
(EXISTING)
13.8KV
5000KVA
4.16KV
(EXISTING)
13.8KV
3-66.7MVA
13.8 KV
BPA SUB FDR NO.2
230 KV
13.8 KV
SJ9.1 BUS 2
230 KV
3-66.7MVA
NAV LOCK FDR NO.2
(*)2000:5
X P
O
SPO2
C200
X P
O
C200
(*)2000:5
:1
V
C200
UNW PUMP FDR NO.2
(3
1200A BUS
(3
:1
V
F D
R
(*)2000:5
1200A BUS
P R
O J S
B
J F F F
D R
N O .1
(3)4000:5
*C400
S P
A R
E
S P
A R
E
J F F F
D R
N O .2
:1
V
(3
S Q
F
D R
P R
O J S
U B F
D R
(3)4000:5
*C400
:1
V
(3
S P
A R
E
4200:120V
(3)
4200:120V
(3)
X P
O
X P
O
HRG
Z J .1
Z J .1
1200:5
S P
A R
E
5000KVA
4.16KV
TO2
13.8KV
1200:5 1200:51200:5
R E
S
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
C H
E C
K E
D B
Y
A N
S I
D
S
C O
T N
E R
S
M
IL
E S P .E
A
B O
S T
R O
M A
U G
U S
T
VOLT.
REG.
TO UO1
TO UO2
VOLT.
REG.
TO CROSS CURRENT
COMPENSATOR/EXCITER
TO CROSS CURRENT
COMPENSATOR/EXCITER
(1)
800:5
600:5
(1)
800:5
600:5
®of Engineers
US Army Corps ®of Engineers
US Army Corps
D R
A W
IN
G N
O
F
IL
E N
A M
E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
W A
L L
A W
A L L
A D
IS
T R
R B
IN
E A
N D G
E N
E R
A T
O R R
E H
A B
IL
IT
A T
IO
N
P O
W E
R H
O U
S E S
T A
T
IO
N S
E R
V
IC
E
C O
L U
M B
IA
R
IV
E R
O R
E G
O N A
N D W
A S
H
IN
G T
O N
M C
N A
R Y L
O C
K A
N D D
P -1 .0
E
D
X X
X .d g n
ED601
C
G
IE
R E
K
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
NOTES:
K
V S
W G
R A
N D S
T A
T
IO
N S
E R
V
IC
E G
E N
E R
A T
O R
S
O N
E L
IN
E D
IA
G R
A M
R E
M O
V A
L
RESOURCE DRAWINGS:
ONE LINE DIAGRAM
SCALE: NTSA4
W
E
F
R
M D
P -1 .0
-6 -1
D
ONE LINE DIAGRAM R1E-603-SK-V2-043
2. CONTRACTOR TO USE EXISTING PT AND PROVIDE NEW CT.
1. ITEMS IN BOLD INDICATE EQUIPMENT TO BE REMOVED.
GR1
GR2
4160/240V
10KVA 1-PH
HRG
OHM RESISTOR
1.587-0.794
C1
C2
C3
C11
C12
C13
Z01
Z03
Z05
Z02
Z04
Z06
SEL-735
Z07
Z08
Z09
Z10
C21
C22
C23
1B11
1B13
1B32
1B12
1B00
1B31
1B33
1B30
521A 277 RPM
4160V 0.8pf
3750KVA
U01
GB
HC
7 10
8 11
7 10
8 11
12 11
4 3
8 7
12 11
2 1
8 7
1 2
5 6
3 4
C0
1B11
1B13
1B12
1B00
(C)
(B)
(A)
(C)
(B)
(A) 1
HC
C31
C32
C33
(SO5 DB)
PTD
MV11
MV13
MV12
(SC10 CX)
PTD
MV11
MV13
MV12
C71
C73
C1X
C111
C113
C4X
V1
V2
1B12
1B13
1B11
1B12
1B13
1B11
:5
6KV, 5.1MCOV
ARRESTER
SURGE
4160V, 1.5UF
CAPACITORS
SURGE
TO AO1.1
TO AO1.1
(SOR5)
RR
IA
IC
IA
IC
VB
VA
VC
VB
VB
VA
VC
VB
(SOR5)
WT1
(SOR5)
WT2
1B11
1B13
1B12
1B00
AC3
AC2
AC1
AC0
AC11
AC12
AC13
AC21
AC22
AC23
HA
E01
SEL-700G
E03
E05
E02
E04
E06
Z09
Z10
Z11
Z12
AC31
AC32
AC33
E07
E08 HA
G3
G2
G1
G0
G11
G12
G13
G21
G22
G23
HB
Z01
Z03
Z05
Z02
Z04
Z06
G31
G32
G33
HB
AC41
AC42
AC43
DA
G41
G42
G43
DB
E01
SEL-700G
E03
E05
E02
E04
E06
Z01
Z03
Z05
Z02
Z04
Z06
AC51
AC52
AC53
DA
G51
G52
G53
G0
E11
E12
GR1
GR2
GR21
GR22
11G U01
DB
SYNC
1B21
1B23
1B22
1B20
IAX
IBX
ICX
IAX
IBX
ICX
IAY
IBY
ICY
IAY
IBY
ICY
E11
E12
18 17
20 19
GR1
GR2
GR11
GR12
CAGA
AC0
18 17
20 19
1B11
1B13
1B11
1B12
1B11
1B13
1B12
1B00
(SOR5)
RR
(SOR5)
RR
HA
HB
(AO1.1)
PTI/1
MV11
MV13
MV0
(AO1.1)
PTI/2
1B11
1B13
1B12
1B00
A Hi
B Hi
C Hi
(SO5 BN)
NEXUS 1250
A Lo
B Lo
C Lo
VA
VC
VB
VREF
VM SW 16SB1CF11
POSITIONS
C-AHANDLE END
CONTACTS
1 2
3 4
B-C A-B OFF
X X
XX
X
X
POSITIONS
CONTACTS
1 2
AM SW 16SB1CA7
X
C I I I B I I I A
X X X X X X X
X X
X X
5 6
X X X X X X X
9 10
X X X X X X X X
X X
X X
X X X
X X X
X
GR1
GR2
B
FV
CA
FV
AB
OFF
BC
CA
(SO6)
DISPLAY
(SC10 CY)
CTD
(SC10 CY)
CTD
(SO5 DE)
CTD
(SO5 DE)
CTD
C O
N T
IN
U E
D O
N E
D
F R
O M U
O M
E T
E R
IN
G P
T
E D
C O
N T
IN
U E
D O
N
F R
O M X
P C
T S
ED613
CONTINUED ON
TO XPO112
TO SYNC SPD DEVICE
13X
U01 VOLTAGE TO SYNC
SYSTEM
AT "S0" BOARDS CONTINUED
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
C H
E C
K E
D B
Y
A N
S I
D
S
C O
T N
E R
S
M
IL
E S P .E
A
B O
S T
R O
M A
U G
U S
T
G0
G3
G2
G1
1 1C
9 9C
5 5C
(SO5 BE)
AM SW
1 3
5 7
1 3
5 7
C1 C2
C3 C4
1 3
5 7
1 3
5 7
6 4 7
P1
P3
P2
P4
22C
1C
33C
44C
(SO5 AG)
0-5000V
VM
6 4 7
(SC10 DB)
AUTO XFMR
(SO5 BD)
VM SW
(SC10 AM)
0-5000V
VM
1 2 1 2
2 3C
:5
:5
(SO5 AH)
0-600A
AM
(SC10 AN)
0-600A
AM
(SO5 AE)
+/-2500KVAR
VAR
(SO5 AF)
0-5MW
WM
(SC10 AR)
+/-2.5MVAR
VAR
(SC10 AS)
0-5MW
WM
SEE ED654
EXCITER
COMPENSATOR/
CURRENT
TO CROSS
(SO5 CD)
AUTO XFMR
(NOTE 2)
(SO5 CE)
TC
®of Engineers
US Army Corps ®of Engineers
US Army Corps
D R
A W
IN
G N
O
F
IL
E N
A M
E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
W A
L L
A W
A L L
A D
IS
T R
R B
IN
E A
N D G
E N
E R
A T
O R R
E H
A B
IL
IT
A T
IO
N
P O
W E
R H
O U
S E S
T A
T
IO
N S
E R
V
IC
E
C O
L U
M B
IA
R
IV
E R
O R
E G
O N A
N D W
A S
H
IN
G T
O N
M C
N A
R Y L
O C
K A
N D D
P -1 .0
E
D
X X
X .d g n
ED611
C
G
IE
R E
K
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
NOTES:
R E
M O
V A
L
U N
IT
S
T A
T
IO
N S
E R
V
IC
E G
E N
E R
A T
O R
T H
R E
E -L
IN
E D
IA
G R
A M
LEGEND: RESOURCE DRAWINGS:
SCALE: NTS
THREE LINE DIAGRAM GENERATOR UNIT 01
A4
W E
F
R
M D
P -1 .0
-6 -1
D
ONE LINE DIAGRAME-203-SSSS
WATT TRANSDUCERWT
WATT METERWM
VOLT METERVM
THERMAL CONVERTERTC
DIG. GOV. FREQ. XDCRPTI
POTENTIAL TEST DEVICEPTD
CURRENT TEST DEVICECTD
AMMETERAM
LONGER SERVES A PURPOSE AND WILL BE REMOVED.
REMOVED IN THE DIGITAL GOVERNOR UPGRADE. THE TC NO
THE ORIGINAL U01/U02 WATT RECORDER SYSTEM THAT WAS
2. EXISTING THERMAL CONVERTER WAS PREVIOUSLY PART OF
AC3
AC2
AC1
AC0
AC11
AC12
AC13
AC21
AC22
AC23
HA
E01
SEL-700G
E03
E05
E02
E04
E06
Z09
Z10
Z11
Z12
AC31
AC32
AC33
E07
E08 HA
G3
G2
G1
G0
G11
G12
G13
G21
G22
G23
HB
Z01
Z03
Z05
Z02
Z04
Z06
G31
G32
G33
HB
AC41
AC42
AC43
DA
G41
G42
G43
DB
E01
SEL-700G
E03
E05
E02
E04
E06
Z01
Z03
Z05
Z02
Z04
Z06
AC51
AC52
AC53
DA
GR1
GR2
G51
G52
G53
G0
C1
C2
C3
C11
C12
C13
Z01
Z03
Z05
Z02
Z04
Z06
SEL-735
Z07
Z08
Z09
Z10
C21
C22
C23
1B11
1B13
1B32
1B12
1B00
1B31
1B33
1B30
11G U02
DB
SYNC
1B21
1B23
1B22
1B20
IAX
IBX
ICX
IAX
IBX
ICX
IAY
IBY
ICY
IAY
IBY
ICY
E11
E12
18 17
20 19
GR1
GR2
GR11
GR12
CAGA
AC0
GB
7 10
8 11
7 10
8 11
12 11
4 3
8 7
12 11
2 1
8 7
1 2
5 6
3 4
C0
1B11
1B13
1B12
1B00
(C)
(B)
(A)
(C)
(B)
(A) 1
C31
C32
C33
A Hi
B Hi
C Hi
A Lo
B Lo
C Lo
VA
VC
VB
VREF
MV11
MV13
MV12
C71
C73
C1X
C111
C113
C4X
V1
V2
1B12
1B13
1B11
1B12
1B13
1B11
1B11
1B13
1B12
1B00
1B11
1B13
1B11
1B12
1B11
1B13
1B12
1B00
1B11
1B13
1B12
1B00
HA
HB
MV11
MV13
MV0
:5
VM SW 16SB1CF11
POSITIONS
C-A
1 2
3 4
A-B OFF
X X
XX
X
X
POSITIONS
1 2
AM SW 16SB1CA7
X
C I I I B I I I A
X X X X X X X
X X
X X
5 6
X X X X X X X
9 10
X X X X X X X X
X X
X X
X X X
X X X
X
B-C
E11
E12
GR1
GR2
GR21
GR22
18 17
20 19
17GR1
GR2
MV11
MV13
MV12U02 VOLTAGE TO SYNC
SYSTEM
AT "S0" BOARDS CONTINUED
(SC10 CZ)
PTD
TO AO2.1TO AO2.1
NEXUS 1250
(SO7 BN)
HC
PTD
(SO7 DB)
(SO8)
DISPLAY
VA
VB
VC
VB
VB
IC
(SOR7)
RR
IA IA
IC
SURGE
(SOR7)
CAPACITORS
4160V, 1.5UF
WT2
VC
VA
VB
(SOR7)
WT1
RR
(SOR7)
RR
(SOR7)
(AO2.1)
PTI/2PTI/1
(AO2.1)
10KVA 1-PH
HRG
4160/240V OHM RESISTOR
1.587-0.794
6KV, 5.1MCOV
ARRESTER
SURGE
(SO7 DE)
CTD
HC
(SC10 DA)
CTD
(SC10 DA)
CTD
(SO7 DE)
CTD
U02
3750KVA
521A 277 RPM
4160V 0.8pf
BCAB
HANDLE END
CA
FV
OFF
CONTACTS
A C B
CONTACTS
FV
TO SYNC SPD DEVICE 13X
E D
C O
N T
IN
U E
D
F
O M X
P C
T S
ED614
CONTINUE ON
TO XPO222
C O
N T
IN
U E
D O
N E
D
F R
O M U
O M
E T
E R
IN
G P
T
1111 1010
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
C H
E C
K E
D B
Y
A N
S I
D
S
C O
T N
E R
S
M
IL
E S P .E
A
B O
S T
R O
M A
U G
U S
T
1 1C
9 9C
5 5C
1 3
5 7
1 3
5 7
C1 C2
C3 C4
1 3
5 7
1 3
5 7
6 4 7
P1
P3
P2
P4
22C
1C
33C
44C
6 4 7
1 2 1 2
2 3C
:5
:5
G3
G2
G1
G0
AUTO XFMR
(SC10 DC)
(SO7 BD)
VM SW
VM
(SO7 AG)
0-5000V
(SC10 AO)
0-5000V
VM
VAR
(SC10 AT)
+/-2.5MVAR
(SC10 AP)
0-5MW
WM
(SC10 AU)
0-600A
AM
(SO7 AH)
VAR
+/-2500KVAR
WM
(SO7 AE)
0-600A
AM
(SO7 AF)
0-5MW TC
(SO7 CE)
(SO7 CD)
AUTO XFMR
(SO7 BE)
AM SW
SEE ED657
EXCITER
COMPENSATOR/
CURRENT
TO CROSS
®of Engineers
US Army Corps ®of Engineers
US Army Corps
D R
A W
IN
G N
O
F
IL
E N
A M
E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
W A
L L
A W
A L L
A D
IS
T R
R B
IN
E A
N D G
E N
E R
A T
O R R
E H
A B
IL
IT
A T
IO
N
P O
W E
R H
O U
S E S
T A
T
IO
N S
E R
V
IC
E
C O
L U
M B
IA
R
IV
E R
O R
E G
O N A
N D W
A S
H
IN
G T
O N
M C
N A
R Y L
O C
K A
N D D
P -1 .0
E
D
X X
X .d g n
ED612
C
G
IE
R E
K
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
NOTES:
R E
M O
V A
L
U N
IT
S
T A
T
IO
N S
E R
V
IC
E G
E N
E R
A T
O R
T H
R E
E -L
IN
E D
IA
G R
A M
LEGEND: RESOURCE DRAWINGS:
THREE - LINE DIAGRAM GENERATOR UNIT 02
SCALE: NTSA4
W E
F
R
M D
P -1 .0
-6 -1
D
ONE LINE DIAGRAME-203-SSSS
WATT TRANSDUCERWT
WATT METERWM
VOLT METERVM
THERMAL CONVERTERTC
DIG. GOV. FREQ. XDCRPTI
POTENTIAL TEST DEVICEPTD
CURRENT TEST DEVICECTD
AMMETERAM
LONGER SERVES A PURPOSE AND WILL BE REMOVED.
REMOVED IN THE DIGITAL GOVERNOR UPGRADE. THE TC NO
THE ORIGINAL U01/U02 WATT RECORDER SYSTEM THAT WAS
2. EXISTING THERMAL CONVERTER WAS PREVIOUSLY PART OF
1. ITEMS IN BOLD INDICATES EQUIPMENT TO BE REMOVED.
1B17 1B18
1B19 1B0
2TD1
2TD3
2TD2
2TD0
1200A
S B
LOCATIONTC3-BS
S B
LOCATIONTC3-NS
C O
N N .2
:5
:5 M
R
B
B
B
B
B
B
B
B
C O
N N .2
:5
:5 M
R
S B
(1
G1
G0
T S -V
S E
L -7
18 20
D A
C41
C42
C43
DA
C3
C2
C1
C0
C11
C12
C13
C21
C22
C23
TS-C
SEL-751
Z01
SEL-751
Z03
Z05
Z02
Z04
Z06
Z09
TS-C
SEL-751
Z01
Z03
Z05
Z02
Z04
Z06
2 1
Z10
Z11
Z12
SEL-735
Z07
Z08
Z09
Z10
G
G
VS #1
1200A
S B
LOCATIONTC3-BS
S B
LOCATIONTC3-NS
C O
N N .2
:5
:5 M
R
C O
N N .2
:5
:5 M
R
VS #2
A X1
X2
X3
X4
6A
PG
P
1E
B
C
4200/120V
A X1
X2
X3
X4
6A
PG
P
1B11
1B12
1B13
1B00
1E
B
C
4200/120V
CT TAP CONNECTION:
1TD0
1TD1
1TD2
1TD3
122A
122N
0-200A
C51
C52
C53
C0
11C31
C32
C33
C31
C32
C33
C0
C31
C32
C33
C0
6AA X1
X2
X3
X4
PG
P
1B19
1B0
1E
B
C
4200/120V
AC1
AC2
AC3
AC0
AMMETER SWITCH
D E
C K
S POSITIONS
C*B*A
CONTACTS
A C
B
2TD1
2TD3
2TD2
2TD0
CA
G10G11 Z07 Z08 181716 15
1B17
1B18
1DV01
1DV02
1DV11
1V2
120/120V
1V17
1V18
1V19
X1-X2
X1-X3
X4-X5
X3-X4
X2-X4
X1-X4
X3-X5
X2-X5
X1-X5
X2-X3 100:5
200:5
300:5
400:5
500:5
600:5
800:5
900:5
1000:5
1200:5
SEC.
TAPS
CURRENT
RATIO
MR CT
1200:5
X1
X2
X3
X4
X5
X1-X2
X4-X5
X2-X3
X2-X4
X1-X3
X1-X4
X2-X5
X1-X5
X3-X4 300:5
400:5
500:5
800:5
1100:5
1200:5
1500:5
1600:5
2000:5
SEC.
TAPS
CURRENT
RATIO
MR CT
2000:5
X1
X2
X3
X4
X5
(SO5)
10A
S P
V
L T
A G
E
S T
E M
A T
S
B
A R
D S
TO BPA SUB
FDR 1
L33
(SPO122)
AA
(SOR9)
XPO122
CD
XPO122
AMMETERAMMETER
SWITCH
XPO122
BD
XPO112
E D
C O
N T
IN
U E
D O
N
"1
G
D
IF
F
R E
L A
Y
T O G
E N
C O
N T
IN
U E
D O
N E
D
A T S
M E
T E
R
IN
G A
N D S
Y N
C
T O G
E N U
U O
V
O L T
A G
E
ED611
CONTINUED ON
GENERATOR
FROM UNIT 01
S E
L -7
"1 T -T
D
IF
F
R E
L A
Y
T O R
E M
O T
E X
F M
R
S E
L -7
"1 T -T
O
D
IF
F
R E
L A
Y
T O R
E M
O T
E X
F M
R
B U
S A
N D M
E T
E R
IN
G
X
M F
R T
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
C H
E C
K E
D B
Y
A N
S I
D
S
C O
T N
E R
S
M
IL
E S P .E
A
B O
S T
R O
M A
U G
U S
T
RV3
RV0
RV1
TEST LINK
(SO6)
E D
C O
N T
IN
U E
D O
N
R E
G U
L A
T O
R
U V
O L T
A G
E
®of Engineers
US Army Corps ®of Engineers
US Army Corps
D R
A W
IN
G N
O
F
IL
E N
A M
E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
W A
L L
A W
A L L
A D
IS
T R
R B
IN
E A
N D G
E N
E R
A T
O R R
E H
A B
IL
IT
A T
IO
N
P O
W E
R H
O U
S E S
T A
T
IO
N S
E R
V
IC
E
C O
L U
M B
IA
R
IV
E R
O R
E G
O N A
N D W
A S
H
IN
G T
O N
M C
N A
R Y L
O C
K A
N D D
P -1 .0
E
D
X X
X .d g n
ED613
C
G
IE
R E
K
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
NOTES:
R E
M O
V A
L
S P
O
K V S
W
IT
C H
G E
A R
T H
R E
E -L
IN
E D
IA
G R
A
RESOURCE DRAWINGS:
SECTION 2
B7SCALE: NTS
SECTION 1
B2
THREE LINE DIAGRAM 5KV SWGR UNIT 01
A4
W E
F
R
M D
P -1 .0
-6 -1
D
5KV CONTROL DIAGRAM SP01 R10.3E-613A-SK-V2-
1B17 1B18
1B19 1B0
1TD1
1TD3
1TD2
1TD0
1200A
S B
LOCATION
S B
LOCATIONTC3-NS
C O
N N .2
:5
:5 M
R
B
B
B
B
B
B
B
B
C O
N N .2
:5
:5 M
R
S B
(1
G1
G0
T S -V
S E
L -7
18 20
H A
C41
C42
C43
HA
C3
C2
C1
C0
C11
C12
C13
C21
C22
C23
TS-C
SEL-751
Z01
SEL-751
G10G11
Z03
Z05
Z02
Z04
Z06
Z07 Z08
Z09
TS-C
SEL-751
Z01
Z03
Z05
Z02
Z04
Z06
2 1
Z10
Z11
Z12
SEL-735
Z07
Z08
Z09
Z10
G
G
VS #3
1200A
S B
LOCATION
S B
LOCATIONTC3-NS
C O
N N .2
:5
:5 M
R
C O
N N .2
:5
:5 M
R
VS #4
A X1
X2
X3
X4
6A
PG
P
1E
B
C
4200/120V
A X1
X2
X3
X4
6A
PG
P
1B11
1B12
1B13
1B00
1E
B
C
4200/120V
1V17
1V18
1TD0
1TD1
1TD2
1TD3
232A
232N
0-200A
C51
C52
C53
C0
11C31
C32
C33
C31
C32
C33
C0
C31
C32
C33
C0
6AA X1
X2
X3
X4
PG
P
1B17
1B18
1B19
1B0
1E
B
C
4200/120V
1B17 1B18
1B19 1B0
AC1
AC2
AC3
AC0
AMMETER SWITCH
D E
C K
S POSITIONS
C*B*A
CONTACTS
A C
B
GA
16 15
(SO7)
2DV01
2DV02
2DV11
2V2
120/120V 1V19
X1-X2
X1-X3
X4-X5
X3-X4
X2-X4
X1-X4
X3-X5
X2-X5
X1-X5
X2-X3 100:5
200:5
300:5
400:5
500:5
600:5
800:5
900:5
1000:5
1200:5
SEC.
TAPS
CURRENT
RATIO
MR CT
1200:5
X1
X2
X3
X4
X5
X1-X2
X4-X5
X2-X3
X2-X4
X1-X3
X1-X4
X2-X5
X1-X5
X3-X4 300:5
400:5
500:5
800:5
1100:5
1200:5
1500:5
1600:5
2000:5
SEC.
TAPS
CURRENT
RATIO
MR CT
2000:5
X1
X2
X3
X4
X5
10A
T O G
E N
D
IF
F
R E
L A
Y
"1
G
C O
N T
IN
U E
D O
N
S P V
O L T
A G
E
T O S
Y N
C S
Y S
T E
M
A T S
B O
A R
D S
TO BPA SUB
FDR 2
XP0232XP0222
L33
(SPO232)(SOR9)
FF
EC DC
XP0232
AMMETER
XP0232
AMMETER
SWITCH
CT TAP CONNECTION:
ED612
CONTINUED ON
GENERATOR
FROM UNIT 02
S E
L -7
"1 T -T
D
IF
F
R E
L A
Y
T O R
E M
O T
E X
F M
R
S E
L -7
"1 T -T
D
IF
F
R E
L A
Y
T O R
E M
O T
E X
F M
R
B U
S A
N D M
E T
E R
IN
G
T O X
F M
R T
E D
C O
N T
IN
U E
D O
N
A T S
M E
T E
R
IN
G A
N D S
Y N
C
T O G
E N U
U V
O L T
A G
E
E -6
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
C H
E C
K E
D B
Y
A N
S I
D
S
C O
T N
E R
S
M
IL
E S P .E
A
B O
S T
R O
M A
U G
U S
T
RV3
RV0
RV1
TEST LINK
(SO8)
E D
C O
N T
IN
U E
D O
N
R E
G U
L A
T O
R
U V
O L T
A G
E ®of Engineers
US Army Corps ®of Engineers
US Army Corps
D R
A W
IN
G N
O
F
IL
E N
A M
E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
W A
L L
A W
A L L
A D
IS
T R
R B
IN
E A
N D G
E N
E R
A T
O R R
E H
A B
IL
IT
A T
IO
N
P O
W E
R H
O U
S E S
T A
T
IO
N S
E R
V
IC
E
C O
L U
M B
IA
R
IV
E R
O R
E G
O N A
N D W
A S
H
IN
G T
O N
M C
N A
R Y L
O C
K A
N D D
P -1 .0
E
D
X X
X .d g n
ED614
C
G
IE
R E
K
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
NOTES:
R E
M O
V A
L
S P
O
K V S
W
IT
C H
G E
A R
T H
R E
E -L
IN
E D
IA
G R
A M
SECTION 3
SECTION 4
THREE LINE DIAGRAM 5KV SWGR SPO2
A2 A6
A4
W E
F
R
M D
P -1 .0
-6 -1
D
5KV SWITCHGEAR SP02 R8.2E-612B-SK-V2
VERTICAL SECTION NO. 1D
N1
P1
R
NB0112
V D
C S
O U
R C
E
SCHEMATIC FOR FEEDER BREAKER XPO112 - TO GENERATOR UNIT 01
1 2
LS
A
M bb
PS2
bb
LOCATION
LS LSPS Y
LC
Y
Y bb aa b
SR
LOCATION
b
LOCATION
PBO112
R
R
2 3
E-MAX
TCM
TCM
30A
30A
CS
C 20A
20A
P
V D
C S
O U
R C
E
PM0112
NM0112
R
52b
T C
M
(S
(S
(S
(S
(S
(S
(S
(S
(S
(S
(S a b a
(S
(S
(S b a b a
(H
(H
(H
(H
(H
(H
(H
(H
(H
(H
(H
(H
(H
(H
LOCATION
b a b a b a b
B K
R C
L O
S E
S T
A T
U S
LOCATION
B K
R O
P E
N
S T
A T
U S
E L E
C
IN
T E
R L
O C
K X
J
LOSS OF 250V DC
B
A
G I
N S
O R
C
RCB
R C
B C
CS
C
CS
T
K42/A1
PLC TRIP
E L E
C
IN
T E
R L
O C
K X
J
S P
A R
E
B R
A K
E S
S P
A R
E
E L E
C
IN
T E
R L
O C
K X
J
E L E
C
IN
T E
R L
O C
K X
J
AUX
TCM
SEL-700G IN304
B K
R R
A C
K E
D I
N S
T A
T U
S
TOC
TOC
TOC
T
RCB
A
S E
E
S C
H
A
86G
TC
a a
TO S02C
M8-05
11T TO1
OUT401
11G UO1
OUT301
GX
X01 86G
86T
TO1
CS
T
RGGG
K44/A1
PLC DB
K40/A1
PLC 0112
25CK-UO1
K40/A2
PLC 0112
SPO1
MAN
SPO1
AUTO
C
D E
C K
B
J
B
C
K22
TO1
TO SOR5
D
C
SEL-700G IN303
TO S0R5
D
IG
G
O V P
L C
A O
.1
M -I
N
25S
(C02)
MB
D01
D02
C01
C02
11 18
16 17
X
T R
IP
N O
R M
A L
C L
O S
E
X
D E
C K
S
CONTACTS
TRIP
CLOSE
XPO112 BREAKER CONTROL SWITCH
MB
JA
1C
1C
A1X
A1Y
A1X
A1Y
A1X
A1Y
8C
A03
A04
A03
A04
A2X
A2Y
(OUT101)
FA
25A-UO1
(OUT407)
EA
UO1-25A
OUT301
C01
C02
EA
JA
SEL751
TS-I/O6
B
S E
E
S C
H
S E
E
S C
H
S E
E
S C
H
S P
A R
E
MOC1 TOC
C
C K
A
C K
D
C K
C
D
E
F
G
C K E
11T-TO1
SEL-787
OUT407
MA
T C
M
T C
M
T C
M a
(S a
(S b
(S b
(S
(S a b
(S a
(S
S P
A R
E
S P
A R
E
S P
A R
E (S
(S
S P
A R
E
S P
A R
E
S P
A R
E (S
(S
(S
S P
A R
E (S
(S
MOC3
16 11
(S
(S
(S
(S
(S
(S
(S
(S
(S
(S a b a b
(S
(S
(S a b a
S P
A R
E
S P
A R
E
S P
A R
E
S P
A R
E
S P
A R
E
S P
A R
E
S P
A R
E
(S
MOC2
MAN
A
B
25S
3C
MA
TO SO2C
TO SO2C
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
C H
E C
K E
D B
Y
A N
S I
D
S
C O
T N
E R
S
M
IL
E S P .E
A
B O
S T
R O
M A
U G
U S
T
V O
L T
A G
E R
E G
U L
A T
IO
N
N H
E X
C
IT
E R R
H E
O S
T A
T C
O N
T R
O L
M R
®of Engineers
US Army Corps ®of Engineers
US Army Corps
D R
A W
IN
G N
O
F
IL
E N
A M
E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
W A
L L
A W
A L L
A D
IS
T R
R B
IN
E A
N D G
E N
E R
A T
O R R
E H
A B
IL
IT
A T
IO
N
M C
N A
R Y L
O C
K A
N D D
P -1 .0
E
D
X X
X .d g n
ED650
C
G
IE
R E
K
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
R E
M O
V A
L
S P
O
K V S
W
IT
C H
G E
A R
X P C
O N
T R
O L D
IA
G R
A M
NOTE 2
LEGEND:
NOTES:
CONTROL DIAGRAM 5KV SPO1 XPO112
A4
W E
F
R
M D
P -1 .0
-6 -4
D
W E
R H
O U
S E S
T A
T
IO
N S
E R
V
IC
E
C O
L U
M B
IA
R
IV
E R
O R
E G
O N A
N D W
A S
H
IN
G T
O N
5KV SWITCHGEAR SP02 R8.2E-612B-SK-V2
RCB = REMOTE PENDANT OPERATOR
LOCATED IN REMOTE PANEL "SO"
LOCATED IN CONTROL ROOM "SC10"
LOCATED IN GOVERNOR PLC CABINET "A01.1"
LOCATED IN THE PLC CABINET "SO2C"
TERMINAL BLOCK IN SPO1
TITLE
BOARD ONLY.
WILL CHANGE. CONTRACTOR TO REMOVE CONNECTIONS TO CONTACTS AT SO6
2. CONTACTS WILL BE REUSED IN NEW EXCITATION SYSTEM. FUNCTION OF CONTACTS
DRAWING NUMBER
VERTICAL SECTION NO. 3D
N1
P1
R
NB0222
V D
C S
O U
R C
E
SCHEMATIC FOR FEEDER BREAKER XP0222 - TO GENERATOR UNIT 02
1 2
LS
A
M bb
PS2
bb
LOCATION
LS LSPS Y
LC
Y
Y bb aa b
SR
LOCATION
b
LOCATION
PB0222
R
R
2 3
E-MAX
TCM
TCM
30A
30A
CS
C 20A
20A
P
V D
C S
O U
R C
E
PM0222
NM0222
R
T C
M
(S
(S
(S
(S
(S
(S
(S
(S
(S
(S
(S a b a
(S
(S
(S b a b a MOC1
(H
(H
(H
(H
(H
(H
(H
(H
(H
(H
(H
(H
(H
(H
LOCATION
TOCb a b a b a b
B K
R C
L O
S E
S T
A T
U S
LOCATION
B K
R O
P E
N
S T
A T
U S
S
S
S
S
E L E
C
IN
T E
R L
O C
K X
J
LOSS OF 250V DC
B
A
G I
N S
O
C
RCB
R C
B C
CS
C
MAN
A
CS
T
K45/A1
PLC TRIP
E L E
C
IN
T E
R L
O C
K X
J
S P
A R
E
B R
A K
E S
S P
A R
E
E L E
C
IN
T E
R L
O C
K X
J
E L E
C
IN
T E
R L
O C
K X
J
AUX
TCM
SEL-700G IN304
B K
R R
A C
K E
D I
N S
T A
T U
S
TOC
TOC
TOC
T
RCB
A
S E
E
S C
H
A
86G
TC
a a
C O
N T 'D O
N S
K -V
-2
-E
D
C O
N T 'D O
N S
K -V
-2
-E
C
TO S02C
M8-05 11T T02
OUT401
11G U02
OUT301
GX
X01
86G 86T
T02
CS
T
RGGG
K47/A1
PLC DB
K41/A3
PLC 0222
25CK-U01
K41/A4
PLC 0222
SP02SP02
AUTO
B
C
D E
C K
B
J
B
C
K22
T02
TO SOR7
D
C
SEL-700G IN303
TO S0R7
D
IG
G
O V P
L C
A .1
M -I
N
25S
25S
(C02)
MB
D01
D02
C01
C02
11 18
16 17
X
T R
IP
N O
R M
A L
C L
O S
E
X
D E
C K
S
CONTACTS
TRIP
CLOSE
XP0222 BREAKER CONTROL SWITCH
MB
JA
1C
1C
A1X
A1Y
A1X
A1Y
A3X
A3Y
10C
A03
A04
A03
A04
A4X
A4Y
(OUT101)
25CK2D
FA
25A-U01
(OUT407)
MAN
DC
EA
U02-25A
OUT301
C01
C02
JA
EA
B
C K
A
S E
E
S C
H
S E
E
S C
H
S E
E
S C
H
S P
A R
E
52b
C
C K E
25CK2C
3C a
(S a
(S b
(S b
(S
(S a b
(S a
(S
S P
A R
E
S P
A R
E
S P
A R
E (S
(S
S P
A R
E
S P
A R
E
S P
A R
E (S
(S
(S
S P
A R
E (S
(S
MOC3
(S
(S
(S
(S
(S
(S
(S
(S
(S
(S a b a b
(S
(S
(S a b a
S P
A R
E
S P
A R
E
S P
A R
E
S P
A R
E
S P
A R
E
S P
A R
E
S P
A R
E
(S
MOC2
11T-TO2
SEL-787
OUT407
MA
MA
a ab b b
TO SO2C
TO SO2C
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
C H
E C
K E
D B
Y
A N
S I
D
S
C O
T N
E R
S
M
IL
E S P .E
A
B O
S T
R O
M A
U G
U S
T
V O
L T
A G
E R
E G
U L
A T
IO
N
N H
E X
C
IT
E R R
H E
O S
T A
T C
O N
T R
O L
M R
®of Engineers
US Army Corps ®of Engineers
US Army Corps
D R
A W
IN
G N
O
F
IL
E N
A M
E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
W A
L L
A W
A L L
A D
IS
T R
R B
IN
E A
N D G
E N
E R
A T
O R R
E H
A B
IL
IT
A T
IO
N
M C
N A
R Y L
O C
K A
N D D
P -1 .0
E
D
X X
X .d g n
ED651
C
G
IE
R E
K
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
R E
M O
V A
L
S P
O
K V S
W
IT
C H
G E
A R
X P C
O N
T R
O L D
IA
G R
A M
NOTES:
NOTE 2
CONTROL DIAGRAM 5KV SPO1 XPO222
LEGEND:
A4
W E
F
R
M D
P -1 .0
-6 -4
D
W E
R H
O U
S E S
T A
T
IO
N S
E R
V
IC
E
C O
L U
M B
IA
R
IV
E R
O R
E G
O N A
N D W
A S
H
IN
G T
O N
5KV SWITCHGEAR SP02 R8.2E-612G-SK-V2
RCB = REMOTE PENDANT OPERATOR
LOCATED IN REMOTE PANEL "SO"
LOCATED IN CONTROL ROOM "SC10"
LOCATED IN GOVERNOR PLC CABINET "A01.1"
LOCATED IN THE PLC CABINET "SO2C"
TERMINAL BLOCK IN SPO1
BOARD ONLY.
WILL CHANGE. CONTRACTOR TO REMOVE CONNECTIONS TO CONTACTS AT SO8
2. CONTACTS WILL BE REUSED IN NEW EXCITATION SYSTEM. FUNCTION OF CONTACTS
PCO1
NCO1
(A01.1)
M7-11
K12
W
(SC10)
W
W
(SO5)
S E
E V
-E
A
T O U
O M
E T
E R
IN
G P
T 7
1B11
R E
S
13X
1B13
(A01.1)
M7-07
K87
13X
(A01.1)
M5-IN13
UNIT AT VOLTAGE
(A01.1)
IN04
M4
(A01.1)
IN03
M4
(A01.1)
IN00
M4
(A01.1)
IN01
M4
86G
9C
87GX
9C
86T01
(A01.1)
IN02
M4
(XPO112)
52a
(SC10)
START
CS
(SC10)
STOP
CS
(SO5)
STOP
CS
(S02C)
PLC SR
K03/A1
(SO5)
START
CS
(S02C)
PLC STOP
K01/A1
(S02C)
START
K00/A1
(SC10)
SR
CS
(SJ9.1C)
SR
CS
(A01.1)
IN05
M4
(SJ9.1C)
SL
CS
(SC10)
SL
CS
FIELD
SERIES
BLKSTS
NSO1
5X
(A01.1)
M5-IN11
131313
12X 38X
QX
141414
12X 38X 63QX
(AO1)
MAN
CS
A
B
12X a
(155 PSI)
Q2
38G38T
A1Y
A1X
R R R
90a
(AO1)
BA
(AO1)
(SC10)
A1Y
(A01.1)
M8-03
K20
A1X
20A
SOL
AUTO(AO1)
CS
20A
Y
20A
M
20A
CL
A-5
A-2
BRAKING
(AO1)
AUTO
CS
A-1
SIREN
PSO1/P5
A-4
91/92
5X
(SPO112)
52b-MOC
BELOW
CONT.
BELOW
CONT.
MANUAL SPEED CONTROLSGOVERNOR START-STOP CONTROLS
(SO5)
RESET SW
OVERSPEED
(A01.1)
IN06
M4
(A01.1)
IN07
M4
(A01.1)
IN08
M4
(A01.1)
IN09
M4
LOWER
CS
RAISE
CS
(SC10) (SC10)
(S02C)
ENABLE
SYNC
K43/B1
(S02C)
ENABLE
SYNC
K43/B2
AUTO SYNC SPEED CONTROL GATE LIMIT CONTROL
(SOR5)
RAISE
OUT403
25A-UO1
(SOR6)
OUT406
11T-TO1
(SJ3.1C)
SR
CS
(SJ3.1C)
SL
CS
(S02C)
PLC SL
K04/A1
OFF
LOWER
MAN AUTO
FV
CONTROL SW (AO1)
GEN BRAKE
POSITIONS
CONT
3 X
X
AUTO
X
MAN
SPD. CONT SWITCH (SC10)
TO OFF
RETURN
SPRING
X
OFF
FV
1 X
STOP
CONT
FV
LOWERRAISE
POSITIONS
OFF
1 X
X
X
X
X
(SO5)(SC10)
AUTO-RUN
CONT
POSITIONS
START
RAISE
PCO1
NCO1
(SC10)
STARTSTOP
15A
U
U
U
U
U
U
U
U
U
U
(A01.1)
M8-02
K19
(A01.1)
IN10
M4
(AO1.1)
CNV/1
P S
M
ABOVE
FROM
CONT.
ABOVE
FROM
CONT.
(A01.1)
IN11
M4
P S
M
(A01.1)
IN01
M5
(SOR6)
OUT405
11T-TO1
U
SPARE
(AO1.1)
CNV/2
(A01.1)
IN03
M5
(SO5)
AUTO
U
IN AUTO
CONTROL
GENERATOR
(A01.1)
IN04
M5
U
(A01.1)
IN05
M5
(YO1)
49XO1
U
RELAY
THERMAL
CO2
(A01.1)
IN06
M5
U
(A01.1)
IN09
M5
(AO1)
63BA
U
(A01.1)
IN10
M5
U
DISENGAGED
WHEEL
HAND
(A01.1)
IN11
M5
(AO1.1)
5X
X -1
LOCKOUT
AUX
(A01.1)
IN12
M5
(AO1.1)
BLK STS
B L
K S
T S -3
LOCKOUT
GOV TRIP
(AO1.1)
IN13
M5
(AO1.1)
13X
U
VOLTAGE
UNIT AT
AT 145%
CLOSES
(G01)
AT 130%
CLOSES
(AO1.1)
M7-08
K9
GENERATOR PROTECTION
A1X
A1Y (A01.1)
M8-04
K21
15A
SIREN
PCO1
NCO1
(AO1.1)
M8-07
K24
38X
13X
SPARE
13X
SPARE
SPARE
SPARE
AUTO
FV
1 X
MAN
CONT
POSITIONS
AUTO
MAN
X
X
X
86G
(A01.1)
M5-IN12
TRIP
RESET
FV
(SO5)
12X OVERSPEED RESET
R E
S E
T
T
IP
1 2
X
86G
12X
ANN/PLC
SPARE
ANN/PLC
SPARE
SPARE
(A01.1)
5X
ANN/PLC
SPARE
SPARE
(A01.1)
SPARE
OPEN
GATES
(SOR6) (SOR6)
(DOME)
CLOSED
GEN BKR
(SOR6) (SOR6) (SOR6)
GENERATOR PROTECTION
(A01.1)
1 2
(SOR5)
LOWER
OUT404
25A-UO1
NORM
LOWER
GATE LIMIT SWITCH (SC10)
FV
LOWER
POSITIONS
NORMAL
1 X
X
X2
CONT
RAISE
RAISE
P24
(AO1.1)
M7-02
K3
86G
7C
A
C
65SD
N24
B
87GX
86T01
B
C
10C
PCO1
NCO1
63QX
VALVE
GATE SHUTDOWN
F R
O M D
IG
G O
V
C A
B
A O
.1
V D
C C
O N
T R
O L P
O W
E R
(AO1)
#1
MONITOR
SUPPLY
POWER
LOW
PRESSURE
AIR
BRAKE
SELECTOR (SO5)
43 OPERATION
#2
MONITOR
SUPPLY
POWER
P O
W E
R C
E O
B
K R
V D
C C
O N
T R
(AO1)
MESH
PINION IS IN
HAND-WHEEL
WHEN
OPENS
CONTACT
ON GOV.
CUT OUT SW
C E
O .1 B
K R
P O
W E
R
V D
C C
O N
T R
RESET
RELAYS
LOCKOUT
AUX. SW
CONT
BRAKE
HAND GRIP
ED653
CONT. ON
ED653
CONT. ON
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
C H
E C
K E
D B
Y
A N
S I
D
S
C O
T N
E R
S
M
IL
E S P .E
A
B O
S T
R O
M A
U G
U S
T
(SXO1)
EXC. BKR
CLOSED
BREAKER
FIELD
(SO6)
REG
TS
MODE
REGULATING
EXCITER
®of Engineers
US Army Corps ®of Engineers
US Army Corps
D R
A W
IN
G N
O
F
IL
E N
A M
E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
W A
L L
A W
A L L
A D
IS
T R
R B
IN
E A
N D G
E N
E R
A T
O R R
E H
A B
IL
IT
A T
IO
N
P O
W E
R H
O U
S E S
T A
T
IO
N S
E R
V
IC
E
C O
L U
M B
IA
R
IV
E R
O R
E G
O N A
N D W
A S
H
IN
G T
O N
M C
N A
R Y L
O C
K A
N D D
P -1 .0
E
D
X X
X .d g n
ED652
C
G
IE
R E
K
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
NOTES:
R E
M O
V
IT
C
O N
T R
O L S
C H
E M
A T
IC
S
H
4 MASTER CONTACTOR OR RELAY
5 STOP DEVICE (EMERG)
11G GENERATOR PROTECTION RELAY
12 OVERSPEED DEVICE
13X SYNCHRONOUS SPEED AUX RELAY
20 ELECTRICALLY OPERATED VALVE
25 SYNCHRONIZING RELAY
38 BEARING THERMAL RELAY
41 FIELD CONTACTOR
43 MAN-AUTO OPERATION SELECTOR SWITCH
49 A-C THERMAL RELAY OR DEVICE
51 A-C OVERCURRENT RELAY
52 A-C CIRCUIT BREAKER OR CONTACTOR
63 FLUID PRESSURE, LEVEL OR FLOW RELAY
65 GOVERNOR
86 LOCKING OUT SHUTDOWN RELAY
87 DIFFERENTIAL CURRENT RELAY
A
B BRAKE
C CLOSE, COIL
F FREQUENCY
G GENERATOR, GREEN OR GATE
L LOW, LOWER, LIMIT OR LINE
M MOTOR OR MANUAL
N NEGATIVE , NORMAL OR NEUTRAL
P POSITIVE
Q OIL OR QUICK
R RED, RAISE, RHEOSTAT, RECEIVER
S SPEED
(S) DEVICE LOCATED ON STRUCTURE
T TRIP, TRANSFORMER, TIME OR TRANSMITTER
V VOLTMETER
W WATER, WEST OR WHITE
X-Y AUXILIARY RELAY
AM AUTO-MANUAL SWITCH
ANN ANNUNCIATOR
(AO1) DEVICES LOCATED IN ACTUATOR CABINET
(A01.1)
BLKSTS BLACK START SWITCH
CC CLOSING COIL
CL CLUTCH
CNV DC-DC CONVERTER
CO2 CARBON DIOXIDE EQUIPMENT
CS CONTROL SWITCH
LS LIMIT SWITCH
MOC MECHANISM OPERATED CONTACT
PLC PROGRAMMABLE LOGIC CONTROLLER
SD SHUTDOWN SOLENOID
SL SPEED LOWER
SR SPEED RAISE
(SC10) DEVICE LOCATED IN SS SWBD IN CONT RM
(SJ3.1C) DEVICE LOCATED IN 15KV SWGR SJ3.1C PLC
(SJ9.1C) DEVICE LOCATED IN 15KV SWGR SJ9.1C PLC
(SO) DEVICE LOCATED IN SS SWBD ON GEN FLOOR
(SO2C) DEVICE LOCATED IN SO2C PLC AT SOR10
(SPO1) DEVICES LOCATED IN SPO1 SWGR
TC TRIP COIL
TS REGULATOR TRANSFER SWITCH
ALTERNATING CURRENT, AMBER, AMMETER,AIR
DEVICES LOCATED IN DIGITAL GOVERNOR PANEL
EXCITATION CONTROL SWITCH1E
REGULATOR VOLTAGERV
CONTROL SCHEMATIC UNIT 01
A4
W E
F
R
M D
P -1 .0
-6 -4
D
CENTRALIZED CONTROL SCHEDULE UNIT 1 R1E-614-SK-V2-176
C09
C10
C11 C12
C13
C14
A10
A11
A12 C15
C16
P C
A
A
A
JB
A01
A02
JB
N C
B
N C
A
P L
C S
P
A
P L
C S
P
A
S
T A
S
T
D
A
D
JC
SEL-735
UO1-WHM
A01
A02
N C
C
P C
C
T C
M
A T
C M
(GB)
SEL-700G
11G-UO1
(GA)
A10
A11
A12
A01
A02
D13
D14
A01
A02
A03
A04
N C
A
N C
B
P C
A
P C
C
P C
C
K N
C
C K
NOTE 1
P C
B
25CK1B
NOTE 1
PCO1
NEUTRAL
NCO1
125VDC
5 52
6 61
C05
C06
CO3
CO4
86G
52TC
86G
65SD
ANN/PLC
52CC
41TC
87GX
ANN/PLC
CO2
SPARE
86G
SPARE
52TC
41TC
SPARE
SPARE
SPARE
SPARE
65SD
87GX
SPARE
X
X
X
X
X
X
X
X
5C
CO3
CO4
CO5
CO6
PC251A
PC1A
12C
25CK1E
12C
7C
9C
3C
4C
11C
8C
1C
10C
2C
5C
6C
12C
7C
9C
3C
4C
11C
8C
1C
10C
2C
5C
6C
TBC-6 TBC-6TBC-8
MM-2 MM-4 MM-6
25CK1C
TBC-5 TBC-5TBC-7
MM-1 MM-3 MM-5
25CK1A
25CK1D
12C
(SOR5)
K1
K2
11G-UO1 GENERATOR PROTECTION
A03 A04
A05 A06
A07 A08
A09
JAC02C01
JAC04C03
C06C05
C08C07
3 4
JA
5 6
JA
D02D01
D04D03
D06D05
D08D07
D10D09
D12D11
D14D13
D16D15
7 8
9 10
2 1
KA
3 4
KA
2 1
KA
5 6
KA
AP01
AP01
2 1
KA
AP01
7 8
KA
2 1
JA
PBO112
PTO1A
2 1
JB
2 1
JB
19 20
JA
17 18
JA
2 1
KA
18 17
KA
9 10
KA
19 20
KA
2 1
KA
11 12
KA
2 1
KA
13 14
KA
2 1
KA
15 16
KA
59X
C09 C10
C11 C12
C13 C14
C15 C16
A06A05
A08A07
A10 A11
A12
A05 A06
A07 A08
A09
SPARE
25CK-UO1 751 SYNC CHECK
D01 D02
D03 D04
D05 D06
D08D07
D10D09
D12D11
D14D13
25A-UO1 700G SYNC
D16D15
A09
SPARE
C02C01
C04C03
C06C05
C08C07
A04A03 5 6
A03 A04 3 4
AP01
2 1
FA
AP01
AP01
2 1
FA
AP01
AP01
2 1
FA
AP01
5 6
7 8
3 4
5 6
7 8
9 10
2 1
EA
PBO112
2 1
EB
2 1
EB
FA
FA
FA
EA
EA
EA
EA
2 1
FA
AP01
18 17
FA
9 10
19 20
FA
FA
EA
EA
EA
EA
EA
FA
2 1
FA
AP01
DC
10 9
DC
AP01
11 12
DC
SPARE
PCO1
PCO1
12 11
JA
16 15
JA
13 14
JA
A1X A1Y
A2X A2Y
A3X A3Y
A4X A4Y
OUT102
OUT103
25A
OUT103
OUT401
25CK
25CK
AP01
PLC DI42-6
OVER EXCITATION
PLC DI42-5
V/HZ
AP01
SPARE
SPARE
AP01
OUT101
OUT302
OUT303
OUT304
OUT101
PLC DI38-4
RT ANN
(THIS DRAWING)
CIRCUITS
BREAKER CLOSE
OUT404
OUT405
OUT402
OUT403
OUT408
OUT301
OUT406
OUT407
OUT407
OUT408
OUT401
86T01 (SO10)
OUT402
86G (SO5)
OUT404
OUT405
OUT406
PLC DI42-1
50/51 ANN
OUT403
TESTING OUTPUT
PLC
K44/1
DB
(SO2C)
PLC DI42-8
BRKF (XPO112)
AP01
PLC DI38-5
TRBL ANN
52CC (XPO112)
11T-TO1IN303
PLC DI42-2
64G
N-4LL-5
(THIS DRAWING)
PCO1
SPARE
L-6L-5
L-4
LL-5
N-7LL-5
SS-4
N-5LL-5
L-2
LL-1
L-3LL-1
59X
PLC DI42-8
11T-TO1 IN303
PLC DI42-2,
64G ANN
BRKF…
This is the start of the file's text. The full file is on GovTribe.