Text version
E
E UGP
UGP
UGP UGP UGP UGP UGP UGP UGP UGP
UGS UGS UGS UGS
UGS
UGS UGS UGS UGS UGS UGS UGS UGS
UGS
UGS
U G
S
U G
S
UGP
UGP
UGP UGP UGP UGP UGP UGP UGP UGP
E E E E E E
E E
E UGP
UGP UGP UGP UGP UGP
UGS UGS
UGS
UGS UGS UGS UGS
UGS
U G
S
UGP
UGP UGP UGP UGP
C-103
M A
T C
H L
IN
E
S E
E S
H E
E T
C -1
M A
T C
H L
IN
E
S E
E S
H E
E T
C -1
C
IV
IL
S
IT
E U
T
IL
IT
Y
L A
Y O
U T
P A
N E
L
McCHORD DRIVE SW
B R
ID
G
E P
O R
T W
A Y
S W
W E
S T
E N
T R
A N
C E
R O
A D
C H
IC
A G
O A
V E S
W
T R
U E
L A
N E
S W
McCHORD DRIVE SW
.0
' (T
Y P
NEW 13.8 kV
DISTRIBUTION POLE LINE
SEE NOTE 4
CLEARING ZONE
150.00' (TYP)
LAKEWOOD
526-T MH 01
NEW 13.8 kV
DISTRIBUTION LINE
3. REMOVE 13.8 kV UNDERBUILD (CONDUCTORS, CROSS ARMS AND BRACKETS, AND ASSOCIATED
GUY WIRES FROM TPU-OWNED 115 kV
TRANSMISSION POLES 484 THRU 480.
4. PROVIDE 13.8 kV OVERHEAD DISTRIBUTION LINE AS
INDICATED, PROVIDE 13.8 kV UNDERGROUND DUCT
BANK FROM POLE 526 AND MANHOLES FROM POLE
526 EAST TO THE RAILROAD TRACKS (SEE SHEET
C-104). UNDERGROUND DUCT BANK SHALL BE
INSTALLED USING DIRECTIONAL BORING IN LIEU OF
TRENCHING.
5. SEE SHEET C-200 FOR UNDERGROUND DUCTBANK
PROFILE.
6. POLE MOUNTED TRANSFORMER TO BE REMOVED
AND REPLACED BY PAD MOUNTED TRANSFORMER
AT POLE 526-T. CONNECT TRANSFORMER
SECONDARY TO EXISTING JUNCTION BOX FOR
EXISTING SIGN AND ROADWAY LIGHTING.
TRANSFORMER SHALL BE 50 kVA, 13800-240/120V.
7. SEE SHEET G-002 FOR LEGEND, ABBREVIATIONS,
AND GENERAL NOTES.
8. SEE SHEET C-700 FOR NEW POWER POLE
COORDINATES
E-501
3DEMOLITION
SEE NOTE 3 (TYP)
A
E-502
SEE NOTE 5
B
E-502
SIMILAR
TRANSITION
02 03 04
KEY PLAN
SEE NOTE 6
NOTES:
1. NEW 13.8 kV CONSTRUCTION SHALL BE GRADE C
PER IEEE C2 UNLESS OTHERWISE NOTED.
2. SEE SHEET E-705 FOR WOOD POLE SCHEDULE
(DEMOLITION AND NEW CONSTRUCTION)
B
E-502
F
E-502
W E
S T
E N
T R
A N
C E
R O
A D
EXISTING SIGN
JUNCTION BOX
EXISTING SIGN
McCHORD DRIVE SW
50 kVA
TRANSFORMER
SEE NOTE 6
3-250 KCMIL & 1 #2 GRD, 4" C
(ROUTE THRU MANHOLE TO
EXISTING SIGN JB)
C
E-502
G E
-5
E-505
G E-502
ENLARGEMENT
NOT TO SCALE
Amendment 0003
Manning, S (man67358) Snapshot
Manning, S (man67358) Snapshot
Manning, S (man67358) Text Box 8/26/16
Manning, S (man67358) Snapshot
G3ECNMJK
Text Box NOTE No. 9: CONTRACTOR TO PROVIDE AND INSTALL PRE-CAST VAULT WITH INSIDE DIMENSIONS OF 4'-0" X 6'-4" X 3'-7" AND SINGLE STEEL LOCKING ACCESS COVER WHICH IS OFFSET ALLOWING FOR PLACEMENT OF TRANSFORMER ON TOP OF VAULT. SECONDARY CONDUIT AND CONDUCTORS ARE TO BE ROUTED THROUGH NEW PRIMARY VAULT ENROUTE TO THE EXISTING McCHORD SIGN JUNCTION BOX. CONDUIT AND CONDUCTORS CAN BE ROUTED DIRECTLY TO THE SIGN JUNCTION BOX ONLY WHEN PULLING CALCULATIONS ARE SUBMITTED TO GOVERMENT DEMONSTRATING THAT THE MAXIMUM PULLING TENSION AND SIDWALL PRESSURE IS NOT EXCEEDED IN ANY BEND PER JBLM/NEC CRITERIA. AN ALTERNATE SOLUTION IS TO PROVIDE AND INSTALL SMALL HANDHOLE ENROUTE PRIOR TO INTERCEPTING THE SIGN JUNCTION BOX - THUS MINIMIZING THE NUMBER OF BENDS.
G3ECNMJK
Callout SEE NOTE No.9
G3ECNMJK
Text Box REV-1 TRANSFORMER VAULT INSTALLATION, NOTE No.9 08AUG2017 mjk
G3ECNMJK
Polygon
G3ECNMJK
Polygon
G3ECNMJK
Text Box
G3ECNMJK
Polygonal Line
G3ECNMJK
Text Box
G3ECNMJK
Polygonal Line x x x x
2-24" CASING PIPES
(SEE DETAIL F ON
SHEET E-502)
x x x x x x x
2-24" CASING PIPES
(SEE DETAIL E
ON SHEET E-502)
C-200
C
IV
IL
U N
D E
R G
R O
U N
D D
U C
T B
A N
K P
R O
F
IL
E
M A
T C
H L
IN
E
S
E E
B E
L O
W
M A
T C
H L
IN
E
S
E E
A B
O V
E
13.8 kV DISTRIBUTION LINE DUCTBANK
(SEE SHEETS C-103 AND C-104 FOR UTILITY LAYOUT)
13.8 kV DISTRIBUTION LINE DUCTBANK
(SEE SHEETS C-103 AND C-104 FOR UTILITY LAYOUT)
Work occurring around the existing Perimeter Security Fence (i.e. excavations, bore pits etc) must continue to maintain the secure conditions as provided by the cantonment fence. Any breach in the security fence will require supplemental measures be made by the contractor to ensure continuous perimeter security is maintained (i.e. supplemental temporary fencing etc.) in coordination with Security Forces criteria.
General Note: As part of the contractor’s ‘Means & Methods’ of accomplishing work, the location of bore pit(s) and length of bore can be adjusted in the field to allow for providing adequate clearances around existing utilities which are to be encountered as identified per the underground ductbank and boring profiles depicted
Amendment 0003
Manning, S (man67358) Snapshot
Manning, S (man67358) Snapshot
Manning, S (man67358) Text Box 8/26/16
G3ECNMJK
Line
G3ECNMJK
Line
G3ECNMJK
Text Box
G3ECNMJK
Polygonal Line
G3ECNMJK
Polygon
G3ECNMJK
Line
G3ECNMJK
Polygon
G3ECNMJK
Text Box REV-1; Bore Pit Allowances and Security Fence Requirements 08Aug2017 mjk
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
UGP
UGP
UGP
UGP
UGP
UGP
UGP
UGP
UGP
UGP
UGP
UGP
UGP
UGP
UGP
UGP
UGP
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
U G
P
NOTES:
1. EXPAND GINGKO SUBSTATION SWITCHGEAR
BUILDING AND ADD TWO 13.8 KV SWITCHGEAR
CUBICLES AND CIRCUIT BREAKERS.
2. SEE SHEET E-705 FOR WOOD POLE SCHEDULE
(DEMOLITION AND NEW CONSTRUCTION)
E-401
E L E
C T
R
IC
A L
E N
L A
R G
E D
G
IN
G K
O P
L A
N
I- 5
HIGHWAY
M A
T C
H L
IN
E
S E
E S
H E
E T
C -1
3. REMOVE 13.8 kV UNDERGROUND RISER FROM POLE
494 TO GINGKO SUBSTATION SWITCHGEAR.
4. PROVIDE 13.8 kV UNDERGROUND DISTRIBUTION TO
POLE 501.
5. SEE CABLE CONDUIT LIST ON SHEET E-601 FOR "A"
THRU "F" AND "UC".
6. SEE SHEETS S-521 AND S-522 FOR STRUCTURAL
DETAILS.
GINGKO
SUBSTATION
DEMOLITION
SEE NOTE 3
E-501
EXISTING
GAS SWITCH
02 03 04
KEY PLAN
MATCHLINE SEE SHEET C-101
MATCHLINE SEE SHEET C-101
GROUNDING ROD
7' CHAINLINK
SECURITY FENCE
GRAVEL
EXISTING
BUILDING
POWER POLE W/
RISER
POWER POLE W/
RISER
#TP32494
NN
0 8' 16'
RELOCATED
VOLTAGE
REGULATOR
SEE
NOTE 1
BYPASS SWITCH
STRUCTURE
EXISTING
TRANSFORMER
30 kVA TRANSFORMER
GAS SWITCH
A
SEE NOTE
4 & 5 (TYP)A
B
E
C
F
VR103
VR104
VR102
VR101
E-505
D
INTERNAL
TO VAULT
MH 04
CLEARING
ZONE
E-402
Amendment 0003
Manning, S (man67358) Snapshot
G3ECNMJK
Text Box
7. REMOVE 13.8kV UNDERBUILD (CONDUCTORS, CROSS-ARMS AND BRACKETS, 13.8 kV CABLE TERMINATIONS AND ARRESTORS) FROM TPU-OWNED POLE #494. 13.8kV SPAN GUY FROM TPU-OWNED POLE #494 TO ADJACENT DISTRIBUTION POLE (WITH RISER) TO THE SOUTHWEST SHALL BE REMOVED, WITH NEW GUY WIRE(S) (QTY:2) TO BE INSTALLED ON BOTH THE ADJACENT DISTRIBUTION POLE (WITH RISER) AND THE TPU-OWNED POLE #494.
G3ECNMJK
Callout SEE NOTE No.7
G3ECNMJK
Line
G3ECNMJK
Text Box Rev-1; Added Note No.7 (TPU-Owned Pole #494 Demolition Work) 31Jul2017 MJK
G3ECNMJK
Callout
WEIGHT OF EXISTING VOLTAGE REGULATOR (TO BE RELOCATED) IS 25.25 TONS
G3ECNMJK
Text Box
8. CONDUIT RUN BETWEEN VOLTAGE REGULATOR AND EXIST'G TRANSFORMER IS TO BE ABOVE GROUND MOUNTED AS INDICATED ON DWG SHT E-601, ITEM-B IN THE 'CABLE LIST' (NOT UG). SEE DETAIL No.1 ON DWG SHT E-402 DEPICTING THE (EIGHT) 4"C (FOUR 4"C TO THE VR, AND FOUR 4"C FROM THE VR) TURNING UP AT THE BYPASS SWITCH SUPPORT STRUCTURE. THE TURN-UP IS TO BE A UNISTRUT-TYPE RACK ATTACHED TO THE SUPPORT STRUCTURE LEG. THE CONDUITS ARE TO EXIT THE TRANSFORMER CONNECTION BOX AT A HEIGHT OF 48-INCHES FOR INSTALLATION ABOVE GROUND. AN INTERMEDIATE SUPPORT CONSISTING OF A UNISTRUT RACK IS TO BE ANCHORED TO THE SLAB. ONLY ONE INTERMEDIATE SUPPORT WILL BE REQUIRED, LOCATED AT THE NORTH EDGE OF THE TRANSFORMER SLAB.
G3ECNMJK
Polygon
G3ECNMJK
Text Box
G3ECNMJK
Polygonal Line
G3ECNMJK
Callout SEE NOTE No.8
G3ECNMJK
Line
G3ECNMJK
Text Box
G3ECNMJK
Polygonal Line
G3ECNMJK
Text Box Rev-2; Added Note No. 8 (Above Ground Conduit Run VR to Transfrmer) 08Aug2017 mjk
| C-103 Site Utility Layout Panel-03_Rev-1_08Aug2017 |
| C-200 Boring Profile_Rev-1_08Aug2017 |
| E-401 Elec Enlarged Gingko Plan_Rev-2_08Aug2017 |