ES-114.pdf
PDF 361 KB Posted
- Solicitation number
- W912DS24B0014
About this file
This document appears to be a site plan for a federal construction contract opportunity. The U.S. Army Corps of Engineers, New York District intends to issue a solicitation for the construction of the Phase II, Contract 4B components of the Port Monmouth Hurricane and Storm Damage Reduction Project in Middletown Township, New Jersey. The project scope includes constructing 1,521 LF of floodwall, 1,040 LF of levee, 3,100 CY of contaminated non-hazardous material removal, 15,510 CY of excess material haul and disposal, 2,405 CY of borrow material, and two road closure gates, among other requirements. The procurement will be a Small Business Set-Aside with an estimated contract value between $50 million and $75 million. The anticipated solicitation release is on or about May 10, 2024, with bids due approximately 30 days later. The base period of performance is 1,300 calendar days from the Notice to Proceed.
View the file
Other files
Show 40 more
Latest 50 of 82 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MATCH LINE SHEET ES-113
MATCH LINE SHEET ES-115
010 20 4020
SCALE: 1" = 20'-0"
ES-114
SITE PLAN - AREA Q
A
U G
-2
A M
E N
D M
E N
T
IS
S
U E
D A
T E h tt p
/w w w .n a n .u s a c e .a rm y .m il
N E
W Y
O R
K
U S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
A
P R
S O
L
IC
IT
A
T
IO
N N
O
W
D A
T E
D E
S C
R
IP
T
IO
N M
A R
K A
P P
R
A P
P R
D
A T
E D
E S
C R
IP
T
IO
N
M A
R K
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E
C O
N T
R A
C T
N O
1 2 3 4 5
D
C
A
B
F I L
E N
A M
E
U S
E R
N A
M E
S u b m i t t e d b y
D
D -M
M M
-Y Y
Y Y
H H
:M M
P l o t
D a t e
-0
N E
W Y
O R
K N
Y
R O
O M
F E
D E
R A
L P
L A
Z A
Sheet of 131
®of Engineers
US Army Corps
New York District
Number
Reference
Sheet
X .X
.X
X .X
.X
P O
R T
M O
N M
O U
T H
N
E W
J E
R S
E Y
P H
A S
E I
I
C O
N T
R A
C T
B
R A
R
IT
A N
B A
Y
S A
N D
Y H
O O
K B
A Y
H U
R R
IC
A
N E
S
T O
R M
D A
M A
G E
R E
D U
C T
IO
N
ES-114
S
IT
E P
L A
N
A R
E A
Q
JC2423MDT
GATE
SLUICE
E
E
E
E
CONDUITS
ENCASED
CONCRETE
COATED (TYP.)
GROUND PVC
2" RSC UNDER
2" RSC
(AREA Q)
ACTUATOR
ELECTRIC
SLUICE GATE
C2-4
TOP OF FLOODWALL
ACCESS POINT
TOP OF FLOODWALL
ACCESS POINT
TOP OF FLOODWALL
ACCESS POINT
Campbel l Ave
JC8672MDT
GUIDE POLE
DETAIL)
PANEL (SEE
NEW ELECTRICAL
120/208V, 3P
TOTAL - 75KVA
JCP&L (3) 25KVA
21588/A57986
JCP&L POLE
BT40939MDT
BT-40189MDT
WINCH
CLOSURE
ROAD
WINCH
CLOSURE
ROAD
4" PVC SCH. 40
2" RSC
SCH. 80
4" PVC
OF FLOODWALL
CONDUIT AT TOP
4" PVC SCH. 40
JC1004MDT
JC-2840MDT
25 FOOT POLE
FLOOD LIGHT ON
TWO (2) - LED
25 FOOT POLE
FLOOD LIGHT ON
TWO (2) - LED
25 FOOT POLE
FLOOD LIGHT ON
TWO (2) - LED
CONDUITS
ENCASED
CONCRETE
JC1003MDT
STRUCT. DWGS.)
GATE (SEE
ROAD CLOSURE
OF FLOODWALL
CONDUIT AT TOP
4" PVC SCH. 40
CampbellAve
CampbellAve
-1.1
G
W
W
W
W
S
R=5.95
G .2
G .2
G .5
C re e k
R d
C o m p to n s C re e k
3.2
3.3
C B
C B
6.4
5.6
C B
23+00
24+00
25+00
22+10
22+20
22+30
22+40
22+50
22+60
22+70
22+80
22+90
23+10
23+20
23+30
23+40
23+50
23+60
23+70
23+80
23+90
24+10
24+20
24+30
24+40
24+50
24+60
24+70
24+80
24+90
CampbellAve
CampbellAve
-1.1
G
W
W
W
W
S
R=5.95
G .2
G .2
G .5
C re e k
R d
C o m p to n s C re e k
3.2
3.3
C B
C B
6.4
5.6
C B
File details come from the government source that posted it. Updated .