This solicitation is for the construction of an Information Systems Node facility at Fort Hamilton, NY. The U.S. Army Corps of Engineers, New York District, will issue a request for proposal for the single-story, 10,872 square foot building structure with redundant power, vehicle parking, storage, security systems, and energy monitoring. The NAICS code is 236220 and project value is between $10-25 million. The period of performance is 730 calendar days from notice to proceed. The facility will include operations support space, offices, warehouse, loading dock, and amenities. Sustainability measures will achieve LEED silver certification and follow DoD energy directives. Proposals must be submitted electronically by the deadline specified in the solicitation posted at SAM.gov under solicitation number W912DS22R0001. The point of contact is the listed contract specialist.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
3.1
4 5
D
4 53.1 4.1
10' - 4 7/16" 4' - 7 9/16"
1' - 6 9/16"
ROOF JOIST
ABOVE, TYP.
CANOPY TO BE DESIGNED,
FURNISHED, AND INSTALLED
BY THE CONTRACTOR.
CANOPY TO BE FRAMED INTO
& SUPPORTED BY EXTERIOR
CMU WALL
M A
X
15' - 0"
CMU WALL
D4
S-305
T/SLAB
0' - 0"
ROOF T/STL LOW
16' - 3"
T/PARAPET
20' - 0 3/8"
D
ROOF T/DECK
LOW
16' - 6"
E
12' - 6"
WALL FOOTING
ENTRANCE SLAB w/
THICKENED SLAB EDGE
/1
CMU WALL
S-305
D4
-7' - 0"
MAX
5' - 0"
CANOPY TO BE DESIGNED,
FURNISHED, AND INSTALLED BY
THE CONTRACTOR. CANOPY TO
BE FRAMED INTO & SUPPORTED
BY EXTERIOR CMU WALL
CMU WALL
D4
S-305
D
CMU WALL
ALUMINUM CANOPY
HANGER PIPE
ALUMINUM CANOPY
SUPPORT BEAM
EXTRUDED ALUMINUM
FASCIA (FRONT AND SIDES)
ARCHITECTURAL
WALL ASSEMBLY
NOTES:
1. CANOPY ANCHORAGE SHALL BE DESIGNED BY THE MANUFACTURER TO RESIST DESIGN LOADS INDICATED
ON THE STRUCTURAL DRAWINGS AND SHALL BE SEATED THROUGH THE STRUCTURAL WYTHE.
2. ANCHOR PENETRATIONS SHALL BE SEALED WATERTIGHT.
3. SEE A7/S-503 FOR CMU REINFORCEMENT AT ANCHORAGE.
4. CANOPY TO BE DESIGNED, FURNISHED, AND INSTALLED BY THE CONTRACTOR. CONTRACTOR TO COORDINATE ANCHORAGE DESIGN WITH MANUFACTURER. DESIGN SUBMITTED TO USACE DESIGN ENGINEER FOR REVIEW/APPROVAL PRIOR TO CONSTRUCTION TO ENSURE STRUCTURAL WALLS ARE ADEQUATE.
HANGER PIPE MAX FACTORED REACTIONS (LRFD):
VERTICAL - 1 KIP
HORIZONTAL (OUT OF PLANE) - 1.5 KIP
MAX FACTORED REACTIONS (LRFD):
VERTICAL - 1 KIP
HORIZONTAL (OUT OF PLANE) - 1.5 KIP
1 2
MAX
5' - 0"
D4
S-305
CANOPY TO BE DESIGNED,
FURNISHED, AND INSTALLED
BY THE CONTRACTOR.
CANOPY BY OTHERS TO BE
FRAMED INTO & SUPPORTED
BY EXTERIOR CMU WALL
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N
O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-305
B U
IL
D
IN
G
S E
C T
IO
N
S
F O
R T
H A
M
IL
T O
N N
Y C
A L
C A
L
J S
-0
-2
RTA SUBMITTAL
IN
F
O R
M A
T
IO
N S
E R
V
IC
IN
G
N O
D E
P ro je c t N u m b e r:
3/8" = 1'-0" A1
CANOPY PLAN -TYPE 2
1/4" = 1'-0" D1
SECTION CL 3.1
3/8" = 1'-0" A5
CANOPY PLAN - TYPE 3
N.T.S.
D4
CANOPY SECTION TYP DETAIL
3/8" = 1'-0"
D7
CANOPY PLAN - TYPE 1
CMU VERTICAL REINFORCEMENT
GROUTED SOLID
MORTAR
NOTES:
1. CMU WALLS SHALL BE 8" CMU WITH VERTICAL REINFORCEMENT AS PER TABLE ABOVE.
2. MAXIMUM SPACING FOR VERTICAL REINFORCEMENT SHALL BE 24" WITH VERTICAL REINFORCEMENT ALSO REQUIRED AT EACH SIDE OF OPENINGS AND AT ALL WALL CORNERS. REFER TO DETAIL C5/S-503.
3. HORIZONTAL REINFORCEMENT SHALL BE CONTINUOUS AT FLOOR AND ROOF LEVELS AND AT TOPS OF
WALLS, AND BE PROVIDED AT 48" MAXIMUM SPACING IN BETWEEN.
4. PARAPET WALLS TO BE FULLY GROUTED AND HORIZONTAL REINFORCEMENT SHALL BE CONTINUOUS
IN BOND BEAMS ALONG TOP OF PARAPET.
5. LINTELS SHALL BE PROVIDED ACROSS THE TOP OF ALL OPENINGS REINFORCED WITH A #6 BAR AND
GROUTED SOLID. REFER TO DETAIL E4/S-503.
6. HORIZONTAL REINFORCEMENT SHALL BE PROVIDED AT 16" MAXIMUM SPACING AT CONTROL JOINTS.
7. CONTROL JOINTS SHALL BE CONTINUOUS AND VERTICAL, AND SHALL OCCUR AT 18 FOOT MAXIMUM
SPACING.
8. CONTROL JOINTS SHALL NOT BE LOCATED AT OPENINGS.
CMU WALL VERTICAL REINFORCEMENT
SIZE AND SPACING
EXTERIOR CMU WALLS #6 @ 24" MAX
INTERIOR CMU SHEAR WALLS #6 @ 24" MAX
INTERIOR WALLS (NON LOAD BEARING) #6 @ 24" MAX
SPACING OF
GROUTED CELLS
24" MAX W/ VERT. REINF.
24" MAX W/ VERT. REINF.
24" MAX W/ VERT. REINF.
VERTICAL REINFORCEMENT SPACING VERTICAL REINFORCEMENT SPACING
GROUTED AS PER
TABLE ABOVE
PARAPET WALL #6 @ 24" MAX FULLY GROUTED
EXTERIOR CMU WALLS AT CANOPY
(AS NOTED IN PLANS) #6 @ 8" MAX FULLY GROUTED
TYPICAL CMU BOND BEAM
/8
0' - 7 5/8"
LINTEL REINFORCEMENT
# 6 CONT.
L = 5 FT MAX
H
8" MIN. BOND BEAM BEARING
8" MIN. BOND BEAM BEARING
NOTES:
1. HORIZONTAL REINFORCEMENT SHALL BE CONTINUOUS AT FLOOR AND ROOF LEVELS AND AT TOPS OF WALLS, AND BE PROVIDED AT 48" MAXIMUM SPACING IN BETWEEN WITHIN BOND BEAMS.
2. LINTELS ACROSS THE TOP OF OPENINGS SHALL BE REINFORCED WITH A # 6 BAR A GROUTED SOLID.
3. OPENINGS IN THE CMU WALLS GREATER THAN 5 FEET SHALL RECEIVE STEEL LINTELS.
GROUTED SOLID
CMU LINTEL
NOTES:
1. USE ONE CORNER BAR FOR EACH LAYER OF REINFORCING.
2. CORNER BARS SHALL MATCH HORIZONTAL STEEL IN SIZE AND SPACING.
CMU VERTICAL
REINFORCEMENT
GROUTED SOLID
HORIZONTAL
REINFORCEMENT
CORNER BAR
DOWELS INTO FOUNDATION TO
MATCH VERTICAL BARS IN SIZE &
LOCATION
TOP OF WALL
BOTTOM OF WALL
OPENING
OPENING TWO (2) FULL HEIGHT VERTICAL
BARS ON EACH SIDE OF OPENING, TYP.
HORIZONTAL BARS AT TOP
& BOTTOM OF WALLS, FLOOR
LEVELS, AND 48" MAX IN
BETWEEN WITHIN BOND BEAMS
VERTICAL BARS AS PER
"CMU WALLS" DETAIL BASED
ON AREA OF BUILDING
HOOK IF MIN LENGTH NOT AVAILABLE
2' - 0" MIN TYP.
REINFORCE & GROUT
LAST TWO CELLS ON
BOTH SIDES OF JOINT
CONTINUOUS FORMED RUBBER
CONTROL JOINT
0' - 0 3/8" TYP.
NOTE: VERTICAL REINFORCEMENT AS PER "CMU
WALLS" DETAIL, BASED ON AREA OF BUIDLING.
REINFORCE & GROUT
LAST TWO CELLS
1/2" STEEL SUPPORT
PLATE
ANGLE STEEL LINTEL
SEE TABLE
CONCRETE MASONRY UNIT
8"X8"X16"
CONCRETE MASONRY UNIT
8"X8"X16"
SEE CMU WALL DETAILS FOR
WALL REINFORCEMENT
REQUIREMENTS
STEEL LINTEL BEARING
ON CMU WALL
ANGLE STEEL LINTEL
AS PER TABLE
SEE ARCH DWGS FOR SIZES AND LOCATIONS
OPENING IN CMU WALLS
MIN.
0' - 8"
MIN.
0' - 8"
SECTION VIEW
LINTEL DESIGN TABLE
OPENING SIZE LINTEL SIZE
LESS THAN 7' - 0" L 8 x 6 x 1/2 (LLH)
LESS THAN 10' - 0" L 8 x 8 x 5/8
NOTE: STEEL LINTELS SHALL BE USED
AT ALL EXTERIOR CMU OPENINGS WITH
CORRESPONDING OPENING SIZE.
L8x8x5/8 LINTEL MIN
CMU BOND BEAM @
OPENINGS IN CMU WALLS
BRICK LINTEL @ OPENINGS IN CMU WALLS BRICK LINTEL @ STEEL LINTEL OPENINGS
1/2" DIA ANCHOR EMBED 5"
MIN INTO GROUTED CELL
@ 12" O.C. FOR ENTIRE
LENGTH OF LINTEL. ANCHOR TO
RESIST 750 LBS OF SHEAR AND
1500 LBS OF TENSION, SERVICE
LEVEL LOADING
1/2" THICK HIGH STRENGTH
STRUCT. THERMAL BREAK PAD
AS PER ARCH DWGS. 1/2" THICK HIGH STRENGTH STRUCT.
THERMAL BREAK PAD AS PER ARCH DWGS.
ARCH WALL ASSEMBLY
0' - 8 5/8"
ARCH WALL ASSEMBLY
0' - 8 5/8"
1/2" DIA ANCHOR EMBED 5"
MIN INTO GROUTED CELL
@ 12" O.C. FOR ENTIRE
LENGTH OF LINTEL. ANCHOR TO
RESIST 750 LBS OF SHEAR AND
1500 LBS OF TENSION, SERVICE
LEVEL LOADING
SEE DETAIL 3/S-502 FOR
LINTEL ANGLE SIZE
CMU @ OPENINGS IN
CMU WALLS
NOTE: PROVIDE CORROSIVE PROTECTION TO EXPOSED STEEL PER GENERAL NOTES.
L8x8x5/8
LINTEL MIN
METAL ROOF
DECK
(2) L6X4X3/8 (LLV)
CLIPS, TYP.
1" CLEAR DISTANCE BETWEEN TOP OF
WALL AND UNDERSIDE OF ROOF DECK.
INSTALL FIRE-PROOFING AS REQUIRED
CMU NON-
BEARING WALL
C3X6 SPANNING BETWEEN JOIST
TOP CHORDS, WEB FACING
UNDERSIDE OF ROOF DECK.
CMU ADDITIONAL #6 BAR VERTICAL
REINFORCEMENT GROUTED SOLID AT
CANOPY SUPPORTS, FULL HEIGHT OF WALL
ANCHORAGE DESIGN COORDINATED WITH
MANUFACTURER REQUIREMENTS. MIN (2)
ANCHORS PER ANCHORAGE PLATE.
BRICK EXTERIOR
FACADE
8" CMU WALL
PARAPET WALL ABOVE, FULLY
GROUTED
BOND BEAM WITH
REINFORCEMENT BARS
VERTICAL REINFORCEMENT
IN GROUTED CELLS
ROOF METAL DECK
BEARING ON ANGLE
L6X6X1/2 A36 CONTINUOUS ANGLE, 1/2" DIA
ANCHORS SPACED 16" MAX, 3" FROM BOTTOM
EDGE OF VERTICAL LEG. ANCHORS SHALL
SUPPORT THE FOLLOWING SERVICE LEVEL
LOADS: SHEAR - 600 LBS, TENSION - 900 LBS
BOND BREAKER
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N
O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-503
C M
U D
E T
A
IL
S
F O
R T
H A
M
IL
T O
N N
Y C
A L
C A
L
J S
-0
-2
RTA SUBMITTAL
IN
F
O R
M A
T
IO
N S
E R
V
IC
IN
G
N O
D E
P ro je c t N u m b e r:
NTS
E1
CMU WALLS
NTS
E4
TYPICAL CMU BOND BEAM DETAIL
NTS
C5
TYPICAL CMU WALL CORNER DETAIL
1/4" = 1'-0"
C7
TYPICAL CMU WALL REINFORCEMENT
NTS
B1
TYPICAL CMU CONTROL JOINT DETAIL
NTS
A1
TYPICAL END OF CMU WALL DETAIL
NTS
E7
STEEL ANGLE LINTEL SUPPORTS
1 1/2" = 1'-0" C1
BRICK VENEER SUPPORT LINTELS
N.T.S.
A5
NON BEARING CMU WALL TO ROOF
DECK
1 1/2" = 1'-0" A7
CANOPY ANCHORAGE REINFORCEMENT DETAIL
N.T.S.
A3
METAL DECK TO CMU WALL
CONNECTION
| Sheets |
| S-305 - BUILDING SECTIONS |
| S-503 - CMU DETAILS |