W912DS19B0017_Amendment_5_-_REVISION_1_RTA_A-005.pdf
PDF 486 KB Posted
- Attached to
- Building 110 Renovation at Watervliet, NY
- Solicitation number
- W912DS19B0017
About this file
Amendment 5 - drawings
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
E- 7 E- 8
E- 9 E- 10
SYMBOL KEY:
EXIT LIGHT
FIRE EXTINGUISHER
EYE WASH
FE
EW
FE FE
FE
FE
FE
FE
FE
FE
FE
FE
EWS EWS
M A
T C
H L
IN
E
S-2
B
INCIDENTAL USE
S-2
S-2
B
F-1 F-1
BAY
2345678910111213141516171819202122
232425
262728
293031
3233343536373839404142434445464748495051525354555657585960616263646566676869
E- 1
TRAVEL DISTANCE
LINE TO EXIT
TRAVEL DISTANCE
PATH- SEE SCHEDULE
FOR DISTANCE
BUILDING 110 - BIG GUN SHOP
NOTE: THIS CODE REVIEW WAS CREATED BASED ON EXISTING CONDITIONS. UPON
PROJECT COMPLETION THE BUILDING WILL COMPLY WITH ALL CODE REQUIREMENTS
NOT CURRENTLY SATISFIED.
APPLICABLE CODES & GUIDELINES
IBC 2015, NFPA 101, UFC 3-600-01
ADA & ABA ACCESSIBILITY GUIDELINES
OCCUPANCY CLASSIFICATION - NON-SEPARATED USE
F-1 (MODERATE HAZARD FACTORY INDUSTRIAL)
B (BUSINESS - ACCESSORY OCCUPANCY)
S-2 (STORAGE - ACCESSORY USE)
CONSTRUCTION TYPE
TYPE IIIB (602.3)
FIRE RESISTANCE RATINGS FOR TYPE IIB (TABLE 601)
PRIMARY STRUCTURAL FRAME 0 HOURS
BEARING WALLS - EXTERIOR 0 HOURS
NONBEARING WALLS AND PARTITIONS 0 HOURS
FLOOR CONSTRUCTION 0 HOURS
ROOF CONSTRUCTION 0 HOURS
OCCUPANCY SEPARATION REQUIREMENTS (TABLE 508.4)
F-1 TO B - NO SEPARATION REQUIREMENT - NON-SPRINKLERED
S-2 TO F-1 ACCESSORY USE - NO SEPARATION REQUIRED
AREA LIMITATIONS PER STORY (TABLE 506.2) - EXEMPT
TYPE IIB - NON-SPRINKLERED
12,000 SQUARE FEET / 2 STORY FOR F-1 OCCUPANCY ALLOWED
9,000 SQUARE FEET ADDED PER 75% FRONTAGE INCREASE (506.2)
_ 21,000 SQUARE FEET PER FLOOR ALLOWED _______________________
209,160 SQUARE FEET PER FLOOR ACTUAL GROSS
UNLIMITED AREA AND HEIGHT PERMITTED PER 503.1.1 SPECIAL INDUSTRIAL OCCUPANCIES
MAXIMUM HEIGHT - 55 FEET -EXEMPT PER 503.1.1 SPECIAL INDUSTRIAL OCCUPANCIES
OCCUPANT CAPACITY (IBC TABLE 1004.1.2; NFPA TABLE 7.3.1.2)
FIRST FLOOR
F-1 AREA = 188,881 SF/ 100 SF/ PERSON = 1,889 PERSONS
B AREA = 3,376 SF/ 100 SF/ PERSON = 55 PERSONS
S-2 AREA = 9,532 SF/ 300 SF/ PERSON = 32 PERSONS
SECOND FLOOR
B AREA = 2,127 SF/ 100 SF/ PERSON = 22 PERSONS
S-2 AREA = 756 SF/ 100 SF/ PERSON = 8 PERSONS
EXIST TRAVEL DISTANCE WITH A SPRINKLER SYSTEM (IDC TABLE 1017.2 NFPA TABLE 42.2.6)-
F-1 - 250 FEET
B - 300 FEET
S-2 - 300 FEET
MEANS OF EGRESS - NOT IN COMPLIANCE
FOUR EXITS PROVIDED (IBC 1006.3.1; NFPA 7.4.1.2); TRAVEL DISTANCE GOVERNS REQUIRING MORE EXIT LOCATIONS:
BUILDING AREAS COMPLY EXCEPT:
EXISTING SECOND FLOOR OFFICE SUITE IS NOT PERMISSIBLE PER NFPA 101 39.2.4.4 BASED ON THE FOLLOWING;
OCCUPANT LOAD: 21 (REQUIRED: < 30) COMPLIES
TRAVEL DISTANCE: (REQUIRED: LESS THAN 100’) DOES NOT COMPLY
EXIT DISCHARGE: (REQUIRED: DIRECT TO OUTSIDE) DOES NOT COMPLY
INTERIOR FINISH REQUIREMENTS - NON-SPRINKLERED (IBC 803.11; NFPA)
INTERIOR EXIT PASSAGE WAYS AND STAIRS - B
INTERIOR ROOMS - C
NOTED DEFICIENCIES:
FACILITY DOES NOT HAVE HANDICAPPED ACCESSIBLE FACILITIES. LOCKER ROOMS AND ACCESSORY OFFICES ARE ON
SECOND FLOORS.
UNOCCUPIED THIRD FLOOR (ROOM 320) APPEARS UNSAFE WITH DAMAGED FLOORS AND LIMITED ACCESS.
NON-RATED
1 HOUR RATED
2 HOUR RATED
3 HOUR RATED
P R
O J E
C T
N O
R T
H
0' 8' 16' 64'32' 0' 6" 1'3"0' 1' 2'6"0' 2' 4'1'0' 2' 4' 8' 16'0' 4' 8' 16' 32'0' 8' 16' 32' 64'0' 4' 8' 32'16'
Q P
K D
E S
IG
N
S
O U
T H
S A
L
IN
A S
T R
E E
T S
Y R
A C
U S
E N
E W
Y O
R K
US Army Corps of Engineers
1 2 3 54
A
B
C
D
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
N E
W Y
O R
K D
IS
T
R
IC
T S
O L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T
E D
B Y
P L O
T S
C A
L E
P
L O
T D
A T
E
C O
N T
R A
C T
N O
W
D S
-1
-D -0
-0
R
E P
A
IR
F A
C
IL
IT
IE
S D
E F
IC
IE
N C
IE
S
B
U
IL
D
IN
G
W A
T E
R V
L
IE
T A
R S
E N
A L
F Y
W
A T
E R
V L
IE
T
N
Y
WARNING: THIS DOCUMENT MAY CONTAIN SENSITIVE SECURITY INFORMATION AND THEREFORE MUST BE TREATED AS A CONFIDENTIAL DOCUMENT. THE INFORMATION CONTAINED IN THIS DOCUMENT MUST BE MAINTAINED IN A CONFIDENTIAL MANNER TO PREVENT COMPROMISING HOMELAND SECURITY AS PROVIDED IN SECTION 214 OF THE HOMELAND SECURITY ACT OF 2002. NO PART OF THIS DOCUMENT SHALL BE REPRODUCED, RELEASED OR DISTRIBUTED WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE UNITED STATES ARMY CORPS OF ENGINEERS, NEW YORK DISTRICT (USACE - NYD). UNAUTHORIZED REPRODUCTION, RELEASE OR DISTRIBUTION MAY RESULT IN CIVIL PENALTY OR OTHER ACTION BY USACE-NYD.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
A S
IN
D
IC
A
T E
D
X
/1
/2
:2
:5
P M
A-005
/3
/2
D e s ig n e r
C h e c k e r A u th o r
B U
IL
D
IN
G
R
E G
U L A
T O
R Y
P L A
N
N O
R T
H E
N D
SCALE: 1/16" = 1'-0"
A1
REGULATORY PLAN - NORTH END
SCHEDULE-TRAVEL DISTANCE PATHS
PATH LENGTH COMMENTS
1 165'-1"
2 159'-2"
3 72'-2"
4 141'-8"
5 79'-9"
6 108'-5"
7 120'-10"
8 231'-10"
9 202'-2"
10 96'-5"
SCALE: 12" = 1'-0"
C2
CODE COMPLIANCE SUMMARY
SCALE: NO SCALE
D1
TRAVEL DISTANCE SCHEDULE
C
O D
E C
O R
R E
C T
IO
N
S
/1 /2
| Sheets |
| A-005 - BUILDING 110 REGULATORY PLAN - NORTH END |
File details come from the government source that posted it.