Binghamton ♦ Canton ♦ Elmira ♦ Plattsburgh ♦ Poughkeepsie ♦ Rochester ♦ Syracuse ♦ Utica ♦ Watertown
Albany 22 Corporate Drive Clifton Park, NY 12065 518-383-9144 (T) atlantictesting.com
ATLANTIC TESTING LABORATORIES
WBE certified company
March 14, 2019
QPK Design 450 South Salina Street, Room 500 Syracuse, New York 13201
Attn: Mr. David McNeil, AIA
Re: Limited Asbestos Survey The Big Gun Shop Building 110- Watervliet Arsenal Watervliet, New York ATL Report No. AT5536AI-01-03-19
Ladies/Gentlemen:
Enclosed is a copy of the Limited Asbestos Survey report prepared for the referenced site. This project was completed in accordance with the scope of work outlined in our contract (ATL No.
AT5998-044-01-19), dated January 22, 2019, and authorized by David McNeil on January 24, 2019.
Please contact our office should you have any questions, or if we may be of further assistance.
Sincerely, ATLANTIC TESTING LABORATORIES, Limited
Tina M. Prouty Project Manager
TMP/JDG/tg
WBE certified company
LIMITED ASBESTOS SURVEY
THE BIG GUN SHOP BUILDING 110 - WATERVLIET ARSENAL
WATERVLIET, NEW YORK
ATL REPORT NO. AT5336AI-01-03-19
PREPARED BY:
ATLANTIC TESTING LABORATORIES, LIMITED
22 Corporate Drive
Clifton Park, New York 12065
PREPARED FOR:
QPK Design, LLP 450 South Salina Street, Room 500
Syracuse, New York 13201
ATL REPORT NO. AT5536AI-01-03-19
March 14, 2019
TABLE OF CONTENTS
1.0 INTRODUCTION
1.1 Purpose
1.2 Project Team and Certifications
2.0 SCOPE OF WORK
2.1 Project Description
2.2 Inaccessible Areas
2.3 Document Review
2.4 Limitations
3.0 ASBESTOS
3.1 Methodology
3.2 Regulatory Compliance
3.3 Summary of Findings
4.0 CONCLUSIONS AND RECOMMENDATIONS
4.1 General
4.2 Asbestos-Containing Materials
APPENDICES
Licenses and Certifications ........................................................................................................ A Sample Location Plans .............................................................................................................. B Laboratory Reports and Custody Documentation ....................................................................... C Summary Tables ........................................................................................................................ D Arcadis US, Inc. Documentation ............................................................................................ E
The Big Gun Shop Building 110 – Watervliet Arsenal, Watervliet, New York March 14, 2019 ATL Report No. AT5536AI-01-03-19
1.0 INTRODUCTION
1.1 Purpose
Atlantic Testing Laboratories, Limited (ATL) was retained by QPK Design, LLP, to perform a limited asbestos survey of designated areas within The Big Gun Shop Building 110 at the Watervliet Arsenal, located at 1 Buffington Street, Watervliet, New York. The limited survey was performed on February 8 through February 19, 2019. The purpose of the limited asbestos survey was to identify asbestos-containing materials (ACM) that are present on exposed surfaces within the subject areas, and may have a significant impact on planned renovation activities. The limited asbestos survey procedures and report format that follow are in general compliance with applicable local, state, and federal rules and regulations.
1.2 Project Team and Certifications
Members of the ATL project team included Tina Prouty, Project Manager; Tina Ganter, Environmental Technician; and Brian Babcock, Environmental Specialist. Certifications of ATL's field survey team members and a copy of applicable company licenses maintained by ATL are included in Appendix A.
2.0 SCOPE OF WORK
2.1 Project Description
The project site is located at 1 Buffington Street, Watervliet, Albany County, New York.
The intent of the limited asbestos survey was to identify suspect ACM that are located within designated areas of the subject building and may be impacted during a proposed renovation project. The limited asbestos survey was conducted for the subject areas, as directed by David McNeil, representing QPK Design, LLP. The roof system, external brick masonry, and east and west window systems were not included in this survey event as directed by representatives of QPK Design. The subject areas were occupied and operational at the time of the sampling event.
2.2 Inaccessible Areas
The extent of inaccessible areas is dependent upon the building type, construction materials, history of renovations and repairs, and project scope. Concealed materials may exist in areas that are not readily exposed to view. Although this limited asbestos survey was performed to identify ACM within the subject areas, potential ACM may have escaped detection that could be encountered during future building demolition and/or renovation activities. Wall, ceiling, floor, and/or other component systems may contain concealed suspect ACM. If any suspect ACM is encountered during demolition and/or renovation activities, the activities disturbing the suspect ACM must stop and the material must be sampled and laboratory analyzed in accordance with applicable regulations.
2.3 Document Review
Documents that were provided to ATL for review during the limited asbestos survey included documentation of previous ACM and Lead Based Paint analysis, dated December 6, 2018, provided by Arcadis US, Inc.
2.4 Limitations
This report has been prepared in accordance with the scope of work outlined in ATL’s contract (ATL No. AT5998-044-01-19), dated January 22, 2019, and should not be used as abatement specifications or design documents. The findings, conclusions, and recommendations presented in this report are based on the field observations made by representatives of ATL and the information provided by representatives of QPK Design, LLP.
Quantities and locations of sampled materials are approximate, and should be verified by the abatement contractor(s) prior to providing actual cost quotations and/or initiating abatement activities. Variations in reported quantities and locations for sampled materials, in addition to the discovery of suspect materials not identified in this report, is possible due to the presence of inaccessible areas, as described in Section 2.2 of this report.
The findings and opinions are relevant to the dates of our site work and should not be relied on to represent conditions at substantially later dates.
3.0 ASBESTOS
3.1 Methodology
A visual examination of the subject areas was conducted by an Asbestos Building Inspector to identify suspect ACM. Functional spaces were identified to assist while locating suspect ACM.
A functional space is defined as a spatially distinct area within a building that contains identifiable populations of building occupants. A functional space may include a room, a group of rooms, or other defined area, and several functional spaces may comprise a single homogeneous sampling area. A homogeneous sampling area is defined as an area that is uniform by color, texture, construction/application, and general appearance. Each identified functional space was visually examined to determine the locations of suspect ACM. These materials were then delineated into homogeneous sampling areas.
Samples of each accessible homogeneous area were collected and placed in clean, labeled containers. The appropriate custody documentation was completed and the suspect ACM samples were submitted to AmeriSci New York (AmeriSci), located in New York, New York.
The samples were laboratory analyzed by polarized light microscopy (PLM) and transmission electron microscopy (TEM) methodologies, as applicable. AmeriSci is a New York State Department of Health (NYSDOH) certified laboratory for PLM and TEM analysis under Environmental Laboratory Approval Program (ELAP) No. 11480. AmeriSci is also accredited by the National Institute of Standards and Technology (NIST), under the National Voluntary Laboratory Accreditation Program (NVLAP).
3.2 Regulatory Compliance
In New York State, there are multiple regulatory agencies that have jurisdiction over ACM in buildings. Asbestos survey requirements are primarily regulated or specified by the New York State Department of Labor (NYSDOL), the New York State Department of Health (NYSDOH), the Occupational Safety and Health Administration (OSHA), and the United States Environmental Protection Agency (EPA).
The NYSDOL established Part 56 of The Official Compilation of Codes, Rules, and Regulations (cited as 12 NYCRR, Part 56) to address the proper identification, handling, removal, and disposal of ACM in buildings. Asbestos survey requirements are specified in Subpart 56-5.1 “Asbestos Survey Requirements for Building/Structure Demolition, Renovation, Remodeling and Repair.” The NYSDOL also works in conjunction with the NYSDOH to establish and maintain asbestos safety training program requirements, and enforce personnel certifications and licensing protocol for asbestos contractors.
The OSHA defines requirements for asbestos surveys and identification of ACM and presumed asbestos-containing materials (PACM) in 29 CFR 1926.1101 (k) “Communication of Hazards.”
Under this regulation, OSHA makes reference to conducting inspections according to
1926.1101 (k)(5)(ii)(B) and 1926.1101 (k)(5)(iii) or pursuant to the requirements of the Asbestos Hazard Emergency Response Act (AHERA) 40 CFR Part 763, Subpart E “Asbestos-Containing Materials in Schools.” The AHERA is regulated by the EPA, and applies to primary and secondary schools only; however, the procedures mandated under AHERA are generally considered the industry standards for surveys, as these are typically the most stringent.
3.3 Summary of Findings
A total of 106 homogeneous areas of suspect ACM were identified during the visual examination, from which 104 bulk samples were collected and subsequently submitted to a NYSDOH approved laboratory for analysis. Approximate sample locations are depicted on the Sample Location Plans, contained in Appendix B. A copy of laboratory reports and sample custody documentation are contained in Appendix C. Table D-I, contained in Appendix D, provides a summary of the identified suspect ACM and associated analytical results.
The EPA, NYSDOL, and other regulatory agencies define ACM as any material containing greater than 1% of asbestos. Materials listed in bold font in Table D-I of Appendix D were determined or assumed to be ACM.
Materials containing trace asbestos (i.e., less than 1%) are not considered ACM; however, OSHA recognizes materials that contain trace amounts of asbestos, and requires these materials be handled in accordance with their standard interpretation letter titled “Requirements for demolition operations involving material containing <1% asbestos “, dated August 13, 1999.
As shown in Table D-I of Appendix D, 4 materials were determined to contain trace amounts of asbestos.
Other materials that were observed, but are not considered suspect ACM, include the following;
• Glass • Nylon-Coated Wire Jacket
• Wood • Metal
• Ceramic Tile • Wooden Doors
4.0 CONCLUSIONS AND RECOMMENDATIONS
The following conclusions and recommendations are prepared from ATL’s understanding that the subject building may be subject to renovation projects. Should the management of the building areas change, it is recommended that the findings be revisited to reflect appropriate operations and management practices for hazardous materials containing items.
4.1 General
1. Concealed regulated hazardous materials may exist at the site that could be encountered during future building renovation activities. Wall, ceiling, floor, roofing, and/or other component systems may contain concealed suspect hazardous materials. If any suspect hazardous materials or hazardous materials-containing items are encountered during demolition and/or renovation activities, the activities disturbing the suspect material must stop and the material must be sampled and laboratory analyzed or otherwise managed pursuant to in accordance with applicable regulations.
4.2 Asbestos-Containing Materials
1. The materials listed in bold in Table D-I of Appendix D were determined or assumed to be
ACM. The referenced table also shows materials that contain trace concentrations of asbestos and are regulated under OSHA.
2. Subpart 56-5(h) of 12 NYCRR Part 56 requires that no demolition, renovation, remodeling, or repair work be commenced by any owner or the owner’s agent prior to the completion of asbestos abatement. Asbestos abatement must be performed by an asbestos abatement contractor that maintains a current asbestos handling license, and employs NYSDOL certified asbestos handlers and supervisors. It is recommended that a 12 NYCRR 56 certified Project Monitor oversee abatement activities.
3. Subpart 56-5(g) of 12 NYCRR Part 56 specifies requirements for transmittal of asbestos survey information by the owner or owner’s agent. One copy of the asbestos survey report shall be sent to the local government entity charged with issuing a permit for such demolition, renovation, remodeling, or repair work under applicable State or local laws. If controlled demolition or pre-demolition activities will be performed, one copy of the asbestos survey report shall be submitted to the appropriate Asbestos Control Bureau district office.
One copy of the asbestos survey report must be kept on the construction site throughout the duration of the asbestos project and any associated demolition, renovation, remodeling, or repair project.
A
APPENDIX A
LICENSES AND CERTIFICATIONS
Asbestos Certificate Code Classifications The following letter codes shown on the enclosed asbestos certificates represent the corresponding asbestos classifications:
A - Asbestos Handler F - Operations & Maintenance B - Allied Trades G - Asbestos Supervisor C - Air Sampling Technician H - Asbestos Project Monitor D - Building Inspector I - Asbestos Project Designer E - Management Planner
New York State – Department of Labor Division of Safety and Health License and Certificate Unit State Campus, Building 12
Albany, NY 12240
ASBESTOS HANDLING LICENSE
Atlantic Testing Laboratories, Limited
P.O. Box 29
Canton, NY 13617
FILE NUMBER: 99-0911
LICENSE NUMBER: 29276
LICENSE CLASS: RESTRICTED
DATE OF ISSUE: 10/31/2018
EXPIRATION DATE: 10/31/2019
Duly Authorized Representative – Marijean B Remington:
This license has been issued in accordance with applicable provisions of Article 30 of the Labor Law of New York State and of the New York State Codes, Rules and Regulations (12 NYCRR Part 56). It is subject to suspension or revocation for a (1) serious violation of state, federal or local laws with regard to the conduct of an asbestos project, or (2) demonstrated lack of responsibility in the conduct of any job involving asbestos or asbestos material.
This license is valid only for the contractor named above and this license or a photocopy must be prominently displayed at the asbestos project worksite. This license verifies that all persons employed by the licensee on an asbestos project in New York State have been issued an Asbestos Certificate, appropriate for the type of work they perform, by the New York State Department of Labor.
Eileen M. Franko, Director SH 432 (8/12) For the Commissioner of Labor
B
APPENDIX B
SAMPLE LOCATION PLANS
ASBESTOS KEY NOTES :
Light Gray Window Glazing
Partial First Floor Sample Location Plan - South
Scale: NTS
Drawing: Project No.: Date :
Albany, NY
Plattsburgh, NY
Canton, NY
Watertown, NY
Poughkeepsie, NY
Syracuse, NY
Elmira, NY
Utica, NY
Binghamton, NY
Rochester, NY
Drawn By:
March 2019
SAMPLE LOCATION PLAN
__ of __
Watervliet Arsenal
The Big Gun Shop Building 110
Watervliet, New York www.AtlanticTesting.com
Scale:
As Noted1 4
WBE Certified Company
JDF AT5536
Tan 1-Inch and 2-Inch TSI Pipe Jacket
AT5536AI97A
AT5536AI97B
AT5536AI98A
AT5536AI98B
AT5536AI99A
AT5536AI99B
AT5536AI13A
AT5536AI13B
AT5536AI08A
AT5536AI08B
AT5536AI08C
AT5536AI44A
AT5536AI45A
AT5536AI46A
AT5536AI47A
AT5536AI48A
AT5536AI48B
AT5536AI49A
AT5536AI49B
AT5536AI52A
AT5536AI52B
AT5536AI52C
AT5536AI53A
AT5536AI53B
AT5536AI53C
AT5536AI56A
AT5536AI57A
AT5536AI58A
AT5536AI58B
AT5536AI07A
AT5536AI07B
AT5536AI56B
AT5536AI57B
AT5536AI39B
AT5536AI15C
AT5536AI42A
AT5536AI42B
AT5536AI17A
AT5536AI17B
AT5536AI17C
AT5536AI18A
AT5536AI18B
AT5536AI18C
LEGEND :
Suspect Asbestos Sample ID and Approximate Location
AT5536AI01A
ATL Room Designation for Labeling Purposes
A
White Pipe TSI associated with Tan 1-Inch and 2-Inch
TSI Pipe Jacket
White Window Overlap Caulk
Off-White Interior Window Glazing
Gray Door Frame Caulk
Partial First Floor Sample Location Plan - Center
Scale: NTS
Drawing: Project No.: Date :
Albany, NY
Plattsburgh, NY
Canton, NY
Watertown, NY
Poughkeepsie, NY
Syracuse, NY
Elmira, NY
Utica, NY
Binghamton, NY
Rochester, NY
Drawn By:
March 2019
SAMPLE LOCATION PLAN
__ of __
Watervliet Arsenal
The Big Gun Shop Building 110
Watervliet, New York www.AtlanticTesting.com
Scale:
As Noted2 4
WBE Certified Company
JDF AT5536
Dark Red and Black Checker Pattern 12- by 12-Inch Floor
Tile
AT5536AI12A
AT5536AI54A
AT5536AI61A
AT5536AI61B
AT5536AI62A
AT5536AI62B
AT5536AI63A
AT5536AI63B
AT5536AI64A
AT5536AI64B
AT5536AI67A
AT5536AI39A
AT5536AI54B
AT5536AI65A
AT5536AI66A
AT5536AI67B
AT5536AI104A
AT5536AI104B
AT5536AI41A
AT5536AI41B
AT5536AI41C
AT5536AI40A
AT5536AI40B
AT5536AI38A
AT5536AI38B
AT5536AI95A
AT5536AI95B
AT5536AI65B
AT5536AI66B
AT5536AI70A
AT5536AI70B
AT5536AI71A
AT5536AI71B
AT5536AI72A
AT5536AI72B
AT5536AI73A
AT5536AI73B
AT5536AI105A
AT5536AI105B
AT5536AI12B
AT5536AI68A
AT5536AI69A
AT5536AI87A
AT5536AI106A
AT5536AI106B
AT5536AI76A
AT5536AI77A
AT5536AI44B
AT5536AI45B
AT5536AI46B
AT5536AI47B
AT5536AI75A
AT5536AI75B
AT5536AI107A
AT5536AI107B
AT5536AI108A
AT5536AI108B
AT5536AI76B
AT5536AI77B
AT5536AI90A
AT5536AI90B
AT5536AI91A
AT5536AI91B
AT5536AI74A
AT5536AI74B
AT5536AI109A
AT5536AI109B
AT5536AI78B
AT5536AI85B
AT5536AI68B
AT5536AI69B
AT5536AI81B
AT5536AI87A
AT5536AI78A
AT5536AI79A
AT5536AI79B
AT5536AI80A
AT5536AI80B
LEGEND :
Suspect Asbestos Sample ID and Approximate Location
AT5536AI01A
ATL Room Designation for Labeling Purposes
A
Note: Closet 114C was homogeneous to Room 114 and sampled accordingly.
Black Mastic Associated with Dark Red and Black
Checker Pattern 12- by 12-Inch Floor Tile
Dark Red 9- by 9-Inch Marbled Floor Tile
Yellow 9- by 9-Inch Sub-Floor Tile
Tan with Orange Streaks 9- by 9-Inch Floor Tile
Gray Window Perimeter Caulk
White 12- by 12-Inch Mottle Floor Tile
Black Mastic Associated with White 12- by 12-Inch Mottle
Floor Tile
14 15
Black Floor Filler Associated with Black with Light Gray
Mottled 12- by 12-Inch Floor Tile
Partial First Floor Sample Location Plan - North
Scale: NTS
Drawing: Project No.: Date :
Albany, NY
Plattsburgh, NY
Canton, NY
Watertown, NY
Poughkeepsie, NY
Syracuse, NY
Elmira, NY
Utica, NY
Binghamton, NY
Rochester, NY
Drawn By:
March 2019
SAMPLE LOCATION PLAN
__ of __
Watervliet Arsenal
The Big Gun Shop Building 110
Watervliet, New York www.AtlanticTesting.com
Scale:
As Noted3 4
WBE Certified Company
JDF AT5536
AT5536AI25A
AT5536AI25B
AT5536AI92A
AT5536AI92B
AT5536AI110A
AT5536AI110B
AT5536AI20A
AT5536AI81A
AT5536AI94B
AT5536AI20B
AT5536AI24A
AT5536AI24B
AT5536AI22A
AT5536AI22B
AT5536AI22C
AT5536AI23A
AT5536AI23B
AT5536AI23C
AT5536AI20C
AT5536AI24C
AT5536AI26A
AT5536AI27A
AT5536AI29A
AT5536AI29B
AT5536AI29C
AT5536AI30A
AT5536AI30B
AT5536AI27B
AT5536AI35A
AT5536AI35B
AT5536AI96A
AT5536AI96B
AT5536AI94A
AT5536AI31A
AT5536AI31B
AT5536AI100A
AT5536AI100B
AT5536AI101A
AT5536AI101B
AT5536AI102A
AT5536AI102B
AT5536AI103A
AT5536AI103B
AT5536AI32A
AT5536AI32B
AT5536AI15A
AT5536AI15B
AT5536AI26B
AT5536AI33A
AT5536AI33B
AT5536AI34A
AT5536AI34B
LEGEND :
Suspect Asbestos Sample ID and Approximate Location
AT5536AI01A
ATL Room Designation for Labeling Purposes
B
C
D
E
F
G
H
I
J
Second Floor Sample Location Plan
Scale: NTS
Drawing: Project No.: Date :
Albany, NY
Plattsburgh, NY
Canton, NY
Watertown, NY
Poughkeepsie, NY
Syracuse, NY
Elmira, NY
Utica, NY
Binghamton, NY
Rochester, NY
Drawn By:
March 2019
SAMPLE LOCATION PLAN
__ of __
Watervliet Arsenal
The Big Gun Shop Building 110
Watervliet, New York www.AtlanticTesting.com
Scale:
As Noted4 4
WBE Certified Company
JDF AT5536
LEGEND :
Suspect Asbestos Sample ID and Approximate Location
AT5536AI01A
ATL Room Designation for Labeling Purposes
A
AT5536AI83A
AT5536AI83B
AT5536AI85A
AT5536AI86A
AT5536AI86B
C
APPENDIX C
LABORATORY REPORTS AND CUSTODY DOCUMENTATION
AuenrScr
Atlantic Testing Laboratories, Attn: Tina Prouty
6431 US Higway 11
Canton, NY 13617
AmeriSci New York
1 17 EAST 3OTH ST.
NEWYORK, NY 10016
lEL: (212) 679-8600 . F M: (212) 679-3114
PLM Bulk Asbestos Report Limited Date Received
Date Examined
ELAP #
RE: 4T5536; Big
03109119 AmeriSci Job # 219031960 03t10t19 P.O. # 19025 11480 Page 1 of 1
Green Shop Bldg. 110; Bldg. 110
Glient No. / HGA Lab No. Asbestos Present Total % Asbestos
4T5536AT12A
21 9031 960-01 Location: Rm 112- Tan Seam Tape
Tan/Brown, Homogeneous, Fibrous, Bulk Material
Cellulose 96 %, Non-fibrous 4 %
A/o NAD 7
(by NYS ELAP 198.1) by Bo Sun on 03/10/19
Analyst Description:
Asbestos Types:
Other Material:
AT5536AT128
21 9031 960-02 Location: Rm 114 - Tan Seam Tape
Tan/Brown, Homogeneous, Fibrous, Bulk Material
Cellulose 95 %, Non-fibrous 5 7o
IVo NAD (by NYS ELAP 198.1) by Bo Sun on 03/10/19
Analyst Description:
Asbestos Types:
Other Material:
Reporting Notes:
(l) This job was - Analygg:d usilg Motic BA3l0 Pol Scope S,4.1 1190000538
Analyzed by: Bo Sun ;[>C .\ .-'- "NAD/NSD =no asbestos det5cted; NA =not analyzed: NfuPS=not analyzed/positive stop, (SOF-V) = Sprayed On Fireproofing containing Vermiculite;
(SM-V) = Surfacing Material containing Vermiculite; PLM Bulk Asbestos Analysis by Appd E to Subpt E, 40 CFR 763 (NVLAP 200546-0), ELAP PLM Method 198.1 for NY friable samples, which includes the identification and quantitation of vermiculite or 198.6 for NOB samples or EPA 400 pt ct by Appd E to Subpt E, 40 CFR 763 (NY ELAP Lab 1 1480); Note:PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. NAD or Trace results by PLM are inconclusive, TEM is currently the only method that can be used to determine if this material can be considered or treated as non asbestos-containing in NY State (also see EPA Advisory for floor tile, FR 59,146,38970,8/1/94) National lnstitute of Standards and Technology Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the lab.This PLM report relates ONLY to the items tested. AIHA-LAP, LLC Lab lD 102843, Rl Cert AAL-094, CT Cert PH-0186, Mass Cert A4000054.
Reviewed By: END OF REPORT
<v H8 urA io ooo
IE
Eo o fo{I
.E !o o E.
E6a t(5 dI tno o (Doo s att FEo
TL
(D iI (0 co E g c u.l o Eo
LL
id
E
.e, B E ar .U -F
*st\ ob(Do EEg E#q IJL.E e<i
=e!9v
= o'!5>o- H -9
I "9o io0&EnE;gtr (n q=o.:
Jr dr tr
@rt
F
.E+ d tr
N tr oz E trlF o N dt z J!.
o ooI z
I oD q, o o& ir,) c!\5 iO c-
S, t-gg
,=crlErlCil; -;;
Elfrf;$ slZ EsF
;ri B
3; e.
$a:$E sli ?r r
.* .s >;
g
Es^^ O H;E::E fl.:alIO al8 899o EF;;
IJJ O
E.
,,-g$ee El e>i*g;2{q elrgx;
91 r^fidtr3 fiIE?Ee sEEE
}G F-5ctlle^ 913> E E Et'! z j.;
dli EEt st gEcc ElEriI -El+ i .i "iI{E EF!:
;i hFl&
>oo s;;
,Er6 6 o6^^dkr
2fr9 d;d s
.gl,E Clls iDl E
-glt fx 8.,IF
OIJ
Etd d aAv t'{a Q t tr'l o
Iz l+{t*t U rq Fl& r=(a a M c)
FA
ac H0 E] FEa rtl t{ trIgI tF t)
Ea
N tr S
FI
tr oq *i U
F
FI
Ea
Nt\ t)!\!\ k !.1!\
D
APPENDIX D
SUMMARY TABLES
D
KEY FOR SUMMARY TABLES
Acronyms for the Known or Assumed ACM:
CFT = Ceramic Floor Tile CWT = Ceramic Wall Tile EPDM = Ethylene Propylene Diene Monomer
HVAC = Heating, Ventilation, and Air Conditioning TSI = Thermal System Insulation
Abbreviations for Friable/ACM Type:
Y = Yes N= No M = Miscellaneous S = Surfacing T = Thermal System Insulation
Descriptions for Conditions:
The listed conditions of Good, Fair, and Poor generally correspond with the AHERA descriptions of Good, Damaged, and Significantly Damaged for different types of materials. The following summarizes additional details relative to the listed conditions.
Surfacing (Surf.) and Miscellaneous (Misc.) Materials
• Good: Material with no visible damage or deterioration, or showing only very limited damage or deterioration
• Fair: Material with characteristics of surface crumbling, blistered, water-stained, gouged, marred, or otherwise abraded over less than one tenth of the surface if the damage is evenly distributed or one quarter if the damage is localized.
• Poor: Material with one or more of the following characteristics:
- Surface crumbling or blistering is present over at least one tenth of the surface, if the damage is evenly distributed or one quarter if the damage is localized.
- One tenth (or one quarter, if localized) of material hanging from the surface, deteriorated, or showing adhesive failure.
- Water stains, gouges, or mars over at least one tenth of the surface if the damage is evenly distributed or one quarter if the damage is localized.
Thermal System Insulation (TSI) Materials
• Good: Material with no visible damage or deterioration, or showing only very limited damage or deterioration
• Fair: Material with one or more of the following characteristics:
- A few water stains or less than one tenth of insulation with missing jackets.
- Crushed insulation or water stains, gouges, punctures, or mars on up to one tenth of the insulation if the damage is evenly distributed or up to one quarter if the damage is localized.
• Poor: Material with one or more of the following characteristics:
- Missing jackets on at least one tenth of the piping or equipment.
- Crushed or heavily gouged or punctured insulation on at least one tenth of the component (pipe runs/risers, boiler, tank, duct, etc.) if the damage is evenly distributed or one quarter if the damage is localized.
Notes:
1 Sample Location Plan(s) are enclosed in Appendix B.
2a NAD = No Asbestos Detected/ 2b ND = Not detected above the laboratory method detection limit.
3 Quantities and locations are approximate and must be verified by asbestos abatement contractors prior to providing actual cost quotations and/or initiating abatement activities.
4 NA = Not Applicable
5 Material is determined to be ACM due to being comingled with asbestos-containing mastic
6 Material is assumed (ACM) based on inaccessibility
7 Reference data in Arcadis US, Inc. sample analysis report.
Table D-I Summary of Suspect ACM and Analytical Results
D1
Material General Location1 Friable / ACM Type % Asbestos2a,2b Condition Sample Numbers7 Estimated
Quantity3,4
White Newer Pipe TSI Jacket
West Center Side, West South Side, and South Center;
Room Nos. 102, 104, 112, 113b, 114, 114a, 135, and 241
Y/T Non-Detect Fair A00497
A00507
A00517
N/A
White Pipe TSI End Sealant
West End, South West, South Center, and North Wall;
Adjacent to Column Nos. A32 and A57
Y/T Non-Detect Fair A00467
A00477
A00487
N/A
Brown Window and Door
Perimeter Caulk
West of Columns G48 and F64;
Adjacent to Column Nos. A22, B23, A32, A37, A62, A67;
Column C68 adjacent to main door
N/M Non-Detect Fair A00197
A00207 N/A
Off-White Cloth Pipe TSI Jacket
South West, Center West, and South
Areas; North Wall;
Column Nos. G48 and C22; Room No.
Y/T Non-Detect Fair A00017
A00027
A00037
N/A
White Pipe TSI
South West, Center West, and South
Areas; North Wall;
Room No. 220
Y/T Non-Detect Fair A00497
A00507
A00517
N/A
Off-White Mudded Pipe TSI Fitting Associated with Off-White Pipe TSI Jacket
South West, Center West, and South
Areas; North Wall;
Room No. 220
Y/T Non-Detect Fair
A00047
A00057
A00067
A00077
A00087
A00097
N/A
Summary of Suspect ACM and Analytical Results Continued
D2
Material General Location1 Friable / ACM Type % Asbestos2a,2b Condition Sample Numbers7 Estimated
Quantity3,4
Black Vibration Dampening Cloth
West Side LP 174 Unit and West Side near G55 Column
N/M NAD Good
AT5536AI07A
AT5536AI07B
N/A
Tan Paper TSI Pipe Jacket
Adjacent to Column No. F59
Y/ T NAD Fair
AT5536AI08A
AT5536AI08B
AT5536AI08C
N/A
Off-White Mudded Pipe TSI
Fitting
Adjacent to Column No. F59
Y/T Assumed6 Fair AT5536AI09 6 Linear Feet
White Gypsum Board
Room Nos. 100, 131, 132, 112, 112 2nd floor, 113, 113 2nd floor, 113a, and 114;
Column Nos. C21, C18, C17, C16 and
C15
Y/M Non-Detect Fair
A00307
A00317
A00427
A00427
N/A
White Joint Compound
Associated with White Gypsum
Board
Room Nos. 100, 131, 132, 112, 112 2nd floor, 113, 113 2nd floor, 113a, and 114;
Column Nos. C21, C18, C17, C16, and
C15
N/M Non-Detect Fair A00507
A00517 N/A
White Seam Tape Associated with
Off-White Gypsum Wall Board
Room Nos. 100, 114, 131, 132, 112 and
112 2nd floor Column Nos. C21, C18, C17, C16 and
C15
N/M NAD Fair
AT5536AI12A
AT5536AI12B
N/A
Light Gray Window Glazing
South End N/ M 1.4 Poor
AT5536AI13A
AT5536AI13B
275 Square Feet
Off-White Lag Cloth Patch TSI
Column Nos. G68, E20, E67, C19, and A22; Adjacent to Walls South West and North
Y/T Non-Detect Fair A00167
A00177
A00187
D3
Material General Location1 Friable / ACM Type % Asbestos2a,2b Condition Sample Numbers7 Estimated
Quantity3,4
Silver HVAC TSI Jacket
Adjacent to column Nos. D68, B5, and
A57 Y / T NAD Fair
AT5536AI15A
AT5536AI15B
AT5536AI15C
N/A
Tan 1-Inch and 2- Inch TSI Pipe
Jacket
Adjacent to column No. C52 1/2
Y/ T 1.5 Fair
AT5536AI17A
AT5536AI17B
AT5536AI17C
80 Linear Feet
White Pipe TSI Associated with
Tan 1-Inch and 2- Inch TSI Pipe
Jacket
Adjacent to column No. C52 1/2
Y / T 26.7 Fair
AT5536AI18A
AT5536AI18B
AT5536AI18C
80 Linear Feet
Off-White Mudded Pipe TSI Fitting Associated with Tan 1- Inch and 2- Inch TSI
Pipe Jacket
Adjacent to column No. C52 1/2
Y / T Assumed6 Fair AT5536AI19 6 Square Feet
Gray Insulation Backing Paper
Associated with Pink Fiberglass
Adjacent to column Nos. C31 1/2, C22, C18, E20, and E5;
Walls North, and East; Room Nos.
135, 143, 144, and
Y / T NAD Poor
AT5536AI20A
AT5536AI20B
AT5536AI20C
N/A
Off-White Interior Window Glazing
Center Interior Wood Windows, North Interior Wood Windows; Room
Nos. 134, 220, and 220A
N/M 3.4 Fair A00777
A00787 163 Square
Feet
Gray Skim Coat Wall Plaster
Adjacent to column No. C21
Y / S NAD Fair
AT5536AI22A
AT5536AI22B
AT5536AI22C
D4
Material General Location1 Friable / ACM Type % Asbestos2a,2b Condition Sample Numbers7 Estimated
Quantity3,4
Gray Base Coat Wall Plaster
Adjacent to column No. C21
Y / S NAD Fair
AT5536AI23A
AT5536AI23B
AT5536AI23C
N/A
Off-White Mudded Pipe TSI Fitting Associated with Gray Insulation Backing Paper Associated with Pink Fiberglass
Adjacent to column No. C18, E20, and E5; Walls East and
North
Y / T NAD Fair
AT5536AI24A
AT5536AI24B
AT5536AI24C
N/A
White Caulk Associated with
Door Frame Room No. 144 N / M NAD Fair
AT5536AI25A
AT5536AI25B
N/A
Brown Floor Expansion Board
Adjacent to column Nos. C18, C17, C16, C15, B4, B5, and A6
East Side, Center East, and South East of Building
N/ M NAD Fair
AT5536AI26A
AT5536AI26B
N/A
Brown 4-Inch Cove Base
Adjacent to column Nos. C18, C17, C16, and C15 N / M NAD Fair
AT5536AI27A
AT5536AI27B
N/A
White Adhesive Associated with
Brown 4-Inch Cove Base
Adjacent to Column Nos. C18, C17, C16, and C15 N/ M Non-Detect Fair
A00677
A00687 N/A
Silver Pipe TSI Jacket
Adjacent to column No. C18
N / T NAD Fair
AT5536AI29A
AT5536AI29B
AT5536AI29C
N/A
Gray Expansion Joint Caulk
Throughout Building N / M NAD Fair
AT5536AI30A
AT5536AI30B
D5
Material General Location1 Friable / ACM Type % Asbestos2a,2b Condition Sample Numbers7 Estimated
Quantity3,4
White Gypsum Associated with
Beige Wall Board Textured Panels
Center of Building Y/M NAD Good
AT5536AI31A
AT5536AI31B
N/A
Brown Expansion Joint Caulk
Adjacent to column Nos. A1 and C1
N / M NAD Fair
AT5536AI32A
AT5536AI32B
N/A
Brown Vibration Dampening Cloth
Adjacent to column No. B5
N / M NAD Good
AT5536AI33A
AT5536AI33B
N/A
Gray Floor Filler Patch
Adjacent to column No. B5
N / M NAD Fair
AT5536AI34A
AT5536AI34B
N/A
Off-White Window Glazing
Adjacent to column No. A16
Interior Windows Room Nos. 141 and
141 2nd Floor
N / M NAD Fair
AT5536AI35A
AT5536AI35B
N/A
Orange Pipe TSI Jacket
Adjacent to column Nos. A16 and A22;
Center East Wall
Y / T Assumed6 Fair AT5536AI36 133 Square
Feet
Off-White Mudded Pipe TSI Fitting Associated with Orange Pipe
TSI Jacket
Adjacent to column Nos. A16 and A22
N / T Assumed6 Fair AT5536AI37 2 Square Feet
Orange Gasket Adjacent to column
No. B29 N / M NAD Fair
AT5536AI38A
AT5536AI38B
N/A
Black Tar Expansion Joint
Patch
Center and South East of Building
N / M NAD Fair
AT5536AI39A
AT5536AI39B
N/A
Gray Door Frame Caulk
Adjacent to column No. B31
N / M 2.4 Fair
AT5536AI40A
AT5536AI40B
4 Square Feet
D6
Material General Location1 Friable / ACM Type % Asbestos2a,2b Condition Sample Numbers7 Estimated
Quantity3,4
Older White Pipe TSI Jacket
Adjacent to column No. A32
Y / T NAD Fair
AT5536AI41A
AT5536AI41B
AT5536AI41C
N/A
White Interface Caulk
Adjacent to column No. A56
N / M NAD Fair
AT5536AI42A
AT5536AI42B
N/A
White 2-by 2-Foot Fissured and
Pinholed Ceiling Tile
Room Nos. 102 and
Y/M Non-Detect Fair A00387
A00397 N/A
Gray Grout Associated with
Large Tan Rectangular CWT
Room Nos. 102, 137, and 136
Y / M NAD Fair
AT5536AI44A
AT5536AI44B
N/A
Off-White Mortar Associated with
Large Tan Rectangular CWT
Room Nos. 102, 137, and 136
Y / M NAD Fair
AT5536AI45A
AT5536AI45B
N/A
Gray Grout Associated with 1-
Inch and 2- Inch Tan and Beige CFT
Room Nos. 102, 137, and 136
N / M NAD Fair
AT5536AI46A
AT5536AI46B
N/A
Gray Mortar Associated with 1-
Inch and 2- Inch Tan and Beige CFT
Room Nos. 102, 137, and 136
Y / M NAD Fair
AT5536AI47A
AT5536AI47B
N/A
Gray Grout Associated with 1-by 1- Inch CFT Patch
Room No. 102 Y / M NAD Fair
AT5536AI48A
AT5536AI48B
N/A
Gray Pattern Mortar Associated with 1- by 1- Inch
CFT Patch
Room No. 102 Y / M NAD Fair
AT5536AI49A
AT5536AI49B
D7
Material General Location1 Friable / ACM Type % Asbestos2a,2b Condition Sample Numbers7 Estimated
Quantity3,4
White Skim Coat Wall Plaster
Room Nos. 103, 134, 135, and 144
Y/S Non-Detect Poor A00607
A00617
A00627
N/A
Gray Base Coat Wall Plaster
Room Nos. 103, 134, 135, and 144
Y/S Non-Detect Poor A00647
A00657
A00667
N/A
White Skim Coat Ceiling Plaster
Room Nos. 103, 104, and 134
Y / S NAD Fair
AT5536AI52A
AT5536AI52B
AT5536AI52C
N/A
Gray Base Coat Ceiling Plaster
Room Nos. 103, 104, and 134
Y / S NAD Fair
AT5536AI53A
AT5536AI53B
AT5536AI53C
N/A
Black 4-Inch Cove Base
Room Nos. 103, 112, 112 2nd Floor, 113, 113 2nd Floor, 114, 114A, and 138
N / M NAD Fair
AT5536AI54A
AT5536AI54B
N/A
Black Adhesive Associated with
Black 4-Inch Cove Base
Room Nos. 103, 112, 112 2nd Floor, 113, 113 2nd Floor, 114, 114A, and 138
N/M Non-Detect Fair A00717
A00727 N/A
Red Fire Stop Room Nos. 104 and
Adjacent to 104 N / M NAD Fair
AT5536AI56A
AT5536AI56B
N/A
Brown Fire Stop Room Nos. 104 and
Adjacent to 104 N / M NAD Fair
AT5536AI57A
AT5536AI57B
N/A
Black Residual Mastic Associated with Painted Floor
Room No. 104 (under floor paint)
N / M NAD Fair
AT5536AI58A
AT5536AI58B
N/A
White 12- by 12- Inch Mottled
Floor Tile
Room Nos. 112, 112- 2nd Floor, 113, and
113B Y/M Non-Detect5 Fair
A00737
A00747 985 Square
Feet
D8
Material General Location1 Friable / ACM Type % Asbestos2a,2b Condition Sample Numbers7 Estimated
Quantity3,4
Black Mastic Associated with White 12- by 12-
Inch Mottled Floor Tile
Room Nos. 112, 112- 2nd Floor, 113, and
113B N/M 2.5 Fair
A00757
A00767 985 Square
Feet
Off-White Grout Associated with 4-by 4- Inch Tan Speckled CWT
Room No. 112 Y / M NAD Fair
AT5536AI61A
AT5536AI61B
N/A
White Adhesive Associated with 4-by 4- Inch Tan Speckled CWT
Room No. 112 N / M NAD Fair
AT5536AI62A
AT5536AI62B
N/A
Black Grout Associted with 1-by 1- Inch Tan CFT
Room No. 112 Y / M NAD Fair
AT5536AI63A
AT5536AI63B
N/A
Gray Mortar Associted with 1-by 1- Inch Tan CFT
Room No. 112 Y / M NAD Fair
AT5536AI64A
AT5536AI64B
N/A
White Grout Associated with 4-by 4- Inch White
Speckled CWT
Room Nos. 113 and 114B
Y / M NAD Fair
AT5536AI65A
AT5536AI65B
N/A
White Adhesive Associated with 4-by 4- Inch White
Speckled CWT
Room Nos. 113 and 114B
N / M NAD Fair
AT5536AI66A
AT5536AI66B
N/A
White Fixture Caulk
Room Nos. 112, 113, and 114B
N/M NAD Fair
AT5536AI67A
AT5536AI67B
D9
Material General Location1 Friable / ACM Type % Asbestos2a,2b Condition Sample Numbers7 Estimated
Quantity3,4
White 2- by 4-Foot Rough Fissured
Ceiling Tile
Room Nos. 114 and 138A
Y / M NAD Fair
AT5536AI68A
AT5536AI68B
N/A
Light Gray 12- by 12-Inch Mottled
Floor Tile
Room Nos. 114, 138A, 238J, and
238G N/M NAD Fair
AT5536AI69A
AT5536AI69B
N/A
Dark Gray Pattern Grout Associated with 1- by 1- Inch Yellow and White
Patterned CFT
Room No. 114B Y / M NAD Fair
AT5536AI70A
AT5536AI70B
N/A
Gray Mortar Associated with 1-by 1- Inch Yellow and White Patterned CFT
Room No. 114B Y / M NAD Fair
AT5536AI71A
AT5536AI71B
N/A
White 2- by 2-Foot Pitted Ceiling Tile
Room No. 114A Y / M NAD Fair
AT5536AI72A
AT5536AI72B
N/A
Gray and Tan Marbled Linoleum
Room No. 114A N / M NAD Good
AT5536AI73A
AT5536AI73B
N/A
Gray Fire Stop Room No. 135 N / M NAD Fair
AT5536AI74A
AT5536AI74B
N/A
White Terrazzo Associated with
Shower Pan Room No. 137 N / M NAD Fair
AT5536AI75A
AT5536AI75B
N/A
Dark Red and Black Checker
Pattern 12- by 12- Inch Floor Tile
Room Nos. 134, 133, 143, and 141
N / M 4.3 Fair
AT5536AI76A-114L1
AT5536AI76B-115L1
3,105 Square Feet
Dark Red and Black Checker
Pattern 12- by 12- Inch Floor Tile
Room Nos. 134, 133, 143, and 141
N / M 3.1 Fair
AT5536AI76A-114L2
AT5536AI76B-115L2
3,105 Square
D10
Material General Location1 Friable / ACM Type % Asbestos2a,2b Condition Sample Numbers7 Estimated
Quantity3,4
Black Mastic Associated with
Dark Red and Black Checker
Pattern Floor Tile
Room Nos. 134, 133, 143, and 141
N / M 2.1 Fair
AT5536AI77A
AT5536AI77B
3,105 Square Feet
White 2- by 4-Foot Smooth Ceiling
Tile
Room Nos. 138, 139, 139A, and 139B
Y / M NAD Fair
AT5536AI78A
AT5536AI78B
N/A
Light Gray Pebble/ Crackle Pattern 12-by 12- Inch Floor
Tile
Room No. 138 N/M NAD Fair
AT5536AI79A
AT5536AI79B
N/A
Black Mastic Associated with
Light Gray 12- by 12-Inch Crackle
Pattern Floor Tile
Room No. 138 N / M NAD Fair
AT5536AI80A
AT5536AI80B
N/A
Tan 4-Inch Cove Base
Room Nos. 138, 138A, 150, 154, 153, and 152 N / M NAD Fair
AT5536AI81A
AT5536AI81B
N/A
Tan Adhesive Associated with Tan 4-Inch Cove
Base
Room Nos. 138, 138A, 150, 154, 153, and 152 N/M Non-Detect Fair
A00447
A00457 N/A
White 2- by 4-Foot Fissured and
Extremely Pinholed Ceiling
Tile
Room No. 238 Y / M NAD Fair
AT5536AI83A
AT5536AI83B
N/A
White 2- by 4-Foot Short-Fissured and
Pinholed Ceiling Tile
Room Nos. 238, 238A, 238C, 238D, 238E, 238F, 238H, 238i, 152, 153, and
Y/M Non-Detect Fair A00367
A00377 N/A
D11
Material General Location1 Friable / ACM Type % Asbestos2a,2b Condition Sample Numbers7 Estimated
Quantity3,4
Black 4-Inch Cove Base
Room Nos. 238, 238A, 238C, 238D, 238E, 238F, 238G, 238H, 238i, 238J, 139, 139A, and 139B
N / M NAD Good
AT5536AI85A
AT5536AI85B
N/A
White Adhesive Associated with
Black 4-Inch Cove Base
Room Nos. 238, 238A, 238C, 238D, 238E, 238F, 238G, 238H, 238i, 238J, 139, 139A, and 139B
N / M NAD Fair
AT5536AI86A
AT5536AI86B
N/A
Black Mastic Associated with
Light Gray 12- by 12-Inch Mottled
Floor Tile
Room Nos. 114, 138A, 238J, and
238G N / M Trace Fair
AT5536AI87A
AT5536AI87B
1,481 Square Feet
Yellow Adhesive Associated with
Gray and Tan Mottled 2- by 2- Foot Carpet Tile
Room Nos. 139, 139A, and 139B
N/M Non-Detect Good A00697
A00707 N/A
Dark Red 9- by 9- Inch Marbled
Floor Tile Room No. 133 N / M 10.2 Fair
AT5536AI90A
AT5536AI90B
6 Square Feet
Black Mastic Associated with
Dark Red 9- by 9- Inch Marbled
Floor Tile
Room No. 133 N / M NAD Fair
AT5536AI91A
AT5536AI91B
N/A
Black and Light Gray 12- by 12-
Inch Mottled Floor Tile
Room No. 144 N / M NAD Fair
AT5536AI92A
AT5536AI92B
D12
Material General Location1 Friable / ACM Type % Asbestos2a,2b Condition Sample Numbers7 Estimated
Quantity3,4
Yellow Mastic Comingled with
White Floor Leveler Associated with Black and Light Gray 12- by 12-Inch Mottled
Floor Tile
Room No. 144 N/M Non-Detect Fair A00347
A00357 N/A
Black Window Butyl
Room Nos. 150, 154, 153, and 152
N / M NAD Fair
AT5536AI94A
AT5536AI94B
N/A
White Window Glazing Patch on Wooden Window
Frames
Room Nos. 220 and 220A
N / M NAD Fair
AT5536AI95A
AT5536AI95B
N/A
Black Door Light Butyl
Room Nos. 154, 153 and 152
N / M NAD Fair
AT5536AI96A
AT5536AI96B
N/A
White Window Glazing Patch on Metal Window
Frames
South Facade Y / M NAD Fair
AT5536AI97A
AT5536AI97B
N/A
Light Gray Door Caulk
South Facade N / M NAD Fair
AT5536AI98A
AT5536AI98B
N/A
White Window Overlap Caulk
South Façade N / M 1.7 Fair
AT5536AI99A
AT5536AI99B
3 Square Feet
Off-White Cementitious Seam Grout
North Façade N / M NAD Fair
AT5536AI100A
AT5536AI100B
N/A
Pink Window Glazing
North Facade N / M NAD Fair
AT5536AI101A
AT5536AI101B
D13
Material General Location1 Friable / ACM Type % Asbestos2a,2b Condition Sample Numbers7 Estimated
Quantity3,4
White Window Glazing Associated with Wooden Windows and
Mullions
North Facade N/M Trace Fair
AT5536AI102A
AT5536AI102B
1,000 Square Feet
Off-White Window Glazing Patch
Associated with Wooden Windows and Mullions
North Facade N / M Trace Fair
AT5536AI103A
AT5536AI103B
N/A
Brown Adhesive Associated with 4-by 4-Inch Speckled
CWT
Room Nos. 113 and
N / M NAD Fair
AT5536AI104A
AT5536AI104B
N/A
Yellow 9- by 9- Inch Sub-Floor Tile
Room Nos. 114A and 114
N / M 6.9 Fair
AT5536AI105A-04L1
AT5536AI105B-04L1
1,396 Square Feet
Black Mastic Associated with
Yellow 9- by 9-Inch Sub-Floor Tile
Room Nos. 114A and
N/M Trace Fair
AT5536AI105A-04L2
AT5536AI105B-04L2
N/A
Clear Glue Associated with
Yellow 9- by 9-Inch Sub-Floor Tile
Room Nos. 114A and
N/M Trace Fair
AT5536AI105A-04L3
AT5536AI105B-04L3
N/A
Tan with Oranges Streaks 9- by 9- Inch Floor Tile
Room No. 114 N / M 2.8 Fair
AT5536AI106A
AT5536AI106B
1,300 Square Feet
Gray Floor Filler Room No. 141 N / M NAD Fair
AT5536AI107A
AT5536AI107B
N/A
Gray Window Perimeter Caulk
Room No. 141 N / M 2.9 Fair
AT5536AI108A
AT5536AI108B
54 Square Feet
D14
Material General Location1 Friable / ACM Type % Asbestos2a,2b Condition Sample Numbers7 Estimated
Quantity3,4
Gray Putty Room No. 135 (Pipe
Penetrations) N / M NAD Fair
AT5536AI109A
AT5536AI109B
N/A
Black Floor Filler Associated with Black with Light
Gray Mottled 12-by 12-Inch Floor
Tile
Room No. 144 N / M 1.9 Fair
AT5536AI110A
AT5536AI110B
320 Square
E
APPENDIX E
ARCADIS US, INC. DOCUMENTATION
Analyzed Date Asbestos Fibrous Non-FibrousTest Color
Non Asbestos
Test Report:Asbestos Analysis of Bulk Material
EMSL Analytical, Inc.
200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com cinnasblab@EMSL.com
041835210 CustomerID: ACAD78BJ CustomerPO: 02118227.0000 ProjectID:
EMSL Order:
Attn: Joe Ashman ARCADIS U.S., Inc.
50 Fountain Plaza Suite 600 Buffalo, NY 14202
Received: 11/29/18 10:40 AM
02118227.0000 - Watervliet Arsenal - Building 10 - Watervliet, NY
Fax: (716) 667-0279 Phone: (716) 667-0900
Project:
12/5/2018Analysis Date:
11/27/2018Collected:
A001 041835210-0001
Description North End - A7 Wall - Cloth Jacketing a/w Fiberglass Pipe Insulation (FPI)
PLM NYS 198.1 Friable 12/5/2018
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
None Detected
Not Analyzed
Not Analyzed
Gray
Sample ID Homogeneity Homogeneous
PLM NYS 198.6 VCM Not Analyzed
Cellulose20.00% Glass5.00%
Non-fibrous (other)75.00%
A002 041835210-0002
Description North End - A19 Wall - Cloth Jacketing a/w Fiberglass Pipe Insulation (FPI)
PLM NYS 198.1 Friable 12/5/2018
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
None Detected
Not Analyzed
Not Analyzed
Gray
Sample ID Homogeneity Homogeneous
PLM NYS 198.6 VCM Not Analyzed
Cellulose20.00% Glass5.00%
Non-fibrous (other)75.00%
A003 041835210-0003
Description North End - A21 Wall - Cloth Jacketing a/w Fiberglass Pipe Insulation (FPI)
PLM NYS 198.1 Friable 12/5/2018
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
None Detected
Not Analyzed
Not Analyzed
Gray
Sample ID Homogeneity Homogeneous
PLM NYS 198.6 VCM Not Analyzed
Cellulose15.00% Glass10.00%
Non-fibrous (other)75.00%
A004 041835210-0004
Description North End - A7 Wall - Approximately 3" Mudded Pipe Fitting a/w FPI
PLM NYS 198.1 Friable 12/5/2018
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
None Detected
Not Analyzed
Not Analyzed
Gray
Sample ID Homogeneity Homogeneous
PLM NYS 198.6 VCM Not Analyzed
Min. Wool20.00% Non-fibrous (other)80.00%
A005 041835210-0005
Description North End - A7 Wall - Approximately 3" Mudded Pipe Fitting a/w FPI
PLM NYS 198.1 Friable 12/5/2018
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
None Detected
Not Analyzed
Not Analyzed
Gray
Sample ID Homogeneity Homogeneous
PLM NYS 198.6 VCM Not Analyzed
Min. Wool20.00% Non-fibrous (other)80.00%
Page 1Test Report 198VCM-7.30.0 Printed: 12/6/2018 7:34:04 PM
Initial Report From 12/06/2018 19:34:04 http://www.EMSL.com mailto:cinnasblab@EMSL.com
Asbestos Fibrous Non-FibrousTest Color Non Asbestos
Test Report:Asbestos Analysis of Bulk Material
EMSL Analytical, Inc.
200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com cinnasblab@EMSL.com
041835210 CustomerID: ACAD78BJ CustomerPO: 02118227.0000 ProjectID:
EMSL Order:
A006 041835210-0006
Description North End - E5 Wall - Approximately 3" Mudded Pipe Fitting a/w FPI
PLM NYS 198.1 Friable 12/5/2018
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
None Detected
Not Analyzed
Not Analyzed
Gray
Sample ID Homogeneity Homogeneous
PLM NYS 198.6 VCM Not Analyzed
Min. Wool20.00% Non-fibrous (other)80.00%
A007 041835210-0007
Description North End - A7 Wall - Approximately 6" Mudded Pipe Fitting a/w FPI
PLM NYS 198.1 Friable 12/5/2018
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
None Detected
Not Analyzed
Not Analyzed
Gray
Sample ID Homogeneity Homogeneous
PLM NYS 198.6 VCM Not Analyzed
Min. Wool30.00% Non-fibrous (other)70.00%
A008 041835210-0008
Description North End - A7 Wall - Approximately 6" Mudded Pipe Fitting a/w FPI
PLM NYS 198.1 Friable 12/5/2018
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
None Detected
Not Analyzed
Not Analyzed
Gray
Sample ID Homogeneity Homogeneous
PLM NYS 198.6 VCM Not Analyzed
Min. Wool30.00% Non-fibrous (other)70.00%
A009 041835210-0009
Description North End - A6 Wall - Approximately 6" Mudded Pipe Fitting a/w FPI
PLM NYS 198.1 Friable 12/6/2018
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
None Detected
Not Analyzed
Not Analyzed
Gray
Sample ID Homogeneity Homogeneous
PLM NYS 198.6 VCM Not Analyzed
Min. Wool35.00% Non-fibrous (other)65.00%
A010 041835210-0010
Description North End - A19 Wall - Brick Mortar
PLM NYS 198.1 Friable 12/5/2018
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
None Detected
Not Analyzed
Not Analyzed
Gray
Sample ID Homogeneity Homogeneous
PLM NYS 198.6 VCM Not Analyzed
Non-fibrous (other)100.00%
A011 041835210-0011
Description North End - A7 Wall - Brick Mortar
PLM NYS 198.1 Friable 12/5/2018
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
None Detected
Not Analyzed
Not Analyzed
Gray
Sample ID Homogeneity Homogeneous
PLM NYS 198.6 VCM Not Analyzed
Non-fibrous (other)100.00%
Page 2Test Report 198VCM-7.30.0 Printed: 12/6/2018 7:34:04 PM
Initial Report From 12/06/2018 19:34:04
Test Report:Asbestos Analysis of Bulk Material
EMSL Analytical, Inc.
200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com cinnasblab@EMSL.com
041835210 CustomerID: ACAD78BJ CustomerPO: 02118227.0000 ProjectID:
EMSL Order:
A012 041835210-0012
Description North End - E7 Wall - Brick Mortar
PLM NYS 198.1 Friable 12/6/2018
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
None Detected
Not Analyzed
Not Analyzed
Gray
Sample ID Homogeneity Homogeneous
PLM NYS 198.6 VCM Not Analyzed
Non-fibrous (other)100.00%
A013 041835210-0013
Description North End - A7 Wall - Parging at Interior Window Sill
PLM NYS 198.1 Friable 12/5/2018
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
None Detected
Not Analyzed
Not Analyzed
Gray
Sample ID Homogeneity Homogeneous
PLM NYS 198.6 VCM Not Analyzed
Non-fibrous (other)100.00%
A014 041835210-0014
Description North End - A19 Wall - Parging at Interior Window Sill
PLM NYS 198.1 Friable 12/5/2018
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
None Detected
Not Analyzed
Not Analyzed
Gray
Sample ID Homogeneity Homogeneous
PLM NYS 198.6 VCM Not Analyzed
Non-fibrous (other)100.00%
A015 041835210-0015
Description Center - A32 Wall - Parging at Interior Window Sill
PLM NYS 198.1 Friable 12/6/2018
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
None Detected
Not Analyzed
Not Analyzed
Gray
Sample ID Homogeneity Homogeneous
PLM NYS 198.6 VCM Not Analyzed
Non-fibrous (other)100.00%
A016 041835210-0016
Description North End - A17 Wall - Lag Cloth Repaired Mudded Fitting
PLM NYS 198.1 Friable 12/5/2018
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
None Detected
Not Analyzed
Not Analyzed
Gray
Sample ID Homogeneity Homogeneous
PLM NYS 198.6 VCM Not Analyzed
Min. Wool40.00% Non-fibrous (other)60.00%
A017 041835210-0017
Description North End - A19 Wall - Lag Cloth Repaired Mudded Fitting
PLM NYS 198.1 Friable 12/5/2018
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
None Detected
Not Analyzed
Not Analyzed
Gray
Sample ID Homogeneity Homogeneous
PLM NYS 198.6 VCM Not Analyzed
Min. Wool40.00% Non-fibrous (other)60.00%
Page 3Test Report 198VCM-7.30.0 Printed: 12/6/2018 7:34:04 PM
Initial Report From 12/06/2018 19:34:04
Test Report:Asbestos Analysis of Bulk Material
EMSL Analytical, Inc.
200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com cinnasblab@EMSL.com
041835210 CustomerID: ACAD78BJ CustomerPO: 02118227.0000 ProjectID:
EMSL Order:
A018 041835210-0018
Description North End - E7 Wall - Lag Cloth Repaired Mudded Fitting
PLM NYS 198.1 Friable 12/6/2018
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
None Detected
Not Analyzed
Not Analyzed
Gray
Sample ID Homogeneity Homogeneous
PLM NYS 198.6 VCM Not Analyzed
Glass10.00% Min. Wool35.00%
Non-fibrous (other)55.00%
A019 041835210-0019
Description North End - A22 Door - Interior Dark Brown Door Frame Caulk
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
12/5/2018
12/6/2018
Not Analyzed
Inconclusive: None Detected
None Detected
Brown
Brown
Sample ID Homogeneity Homogeneous
PLM NYS 198.6 VCM Not Analyzed
A020 041835210-0020
Description North End - A22 Door - Interior Dark Brown Door Frame Caulk
PLM NYS 198.1 Friable
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
12/5/2018
12/6/2018
Not Analyzed
Inconclusive: None Detected
None Detected
Brown
Brown
Sample ID Homogeneity Homogeneous
PLM NYS 198.6 VCM Not Analyzed
A021 041835210-0021
Description North End - C Office - Single Coat Plaster
PLM NYS 198.1 Friable 12/5/2018
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
None Detected
Not Analyzed
Not Analyzed
Gray
Sample ID Homogeneity Homogeneous
PLM NYS 198.6 VCM Not Analyzed
Synthetic10.00% Non-fibrous (other)90.00%
A022 041835210-0022
Description North End - C Office - Single Coat Plaster
PLM NYS 198.1 Friable 12/5/2018
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
None Detected
Not Analyzed
Not Analyzed
Gray
Sample ID Homogeneity Homogeneous
PLM NYS 198.6 VCM Not Analyzed
Synthetic10.00% Non-fibrous (other)90.00%
A023 041835210-0023
Description North End - C Office - Single Coat Plaster
PLM NYS 198.1 Friable 12/6/2018
PLM NYS 198.6 NOB
TEM NYS 198.4 NOB
None Detected
Not Analyzed
Not Analyzed
Gray
Sample ID Homogeneity Homogeneous
PLM NYS 198.6 VCM Not Analyzed
Hair4.00% Non-fibrous (other)96.00%
Page 4Test Report 198VCM-7.30.0 Printed: 12/6/2018 7:34:04 PM
Initial Report From 12/06/2018 19:34:04
Test Report:Asbestos Analysis of Bulk Material
EMSL Analytical, Inc.
200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com cinnasblab@EMSL.com
041835210 CustomerID: ACAD78BJ CustomerPO: 02118227.0000 ProjectID:
EMSL Order:
A024 041835210-0024
Description North End - C Office - 12"x12"…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.