US Army Corps of Engineers New York District
SY
M
BO
L
R
EV
IS
IO
N D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
D
AT
E:
SC
A L
E:
D R
A W
IN
G C
O D
E :
D
ES
IG
N
ED
B
Y:
D R
A W N
B Y :
C H
E C
KE
D B
Y:
IS
S U
E D
AT
E:
D
AT
E:
EN
G
IN
EE
R
AR
C H
IT
EC
T N
AM
E
PR
O
JE
C
T
EN
G
IN
EE
R
A R
C H
IT
EC
T
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
C O
R
PS
O F
EN
G
IN
EE
R S
N
EW
Y O
R K
D
IS
TR
IC
T, N
Y
SHEET
REFERENCE
NUMBER:
DATE:
FILE PATH: C:\Users\e3endnmw\Documents\ARCH_FY13_REVISED_E3ENDNMW.rvt
1/8/2013 5:10:17 PM
G-004
N W
N W
M J
FY
D
O R
M
IT
O R
Y, TH
U
LE
A
FB
, G R
EE
N
LA
N
D
LI
FE
S
AF
ET
Y
PL
ANLEGEND
FIRE EXTINGUISHER CABINET
TRAVEL PATH
1/2 HOUR FIRE RATED WALL
1 HOUR FIRE RATED WALL
EMERGENCY LIGHT
EXIT LIGHT
OCCUPANCY NUMBER (4.6 SM PER PERSON, PER TABLE 1004.1 OF IBC 2009)
0 10,000MM 20,000MM
CODE ANALYSIS
UNITED FACLITIES CRITERIA (UFC) 1-200-01/ 2009 EDITION
UFC 3-600-01/ 2009 EDITION
NFPA 90A / 2009 EDITION
NFPA 101 LIFE SAFETY CODE 2009 EDITION
1. OCCUPANCY CLASSIFICATION
2. CONSTRUCTION TYPE
3. GROSS AREA PER FLOOR
4. OCCUPANCY
5. HEIGHT AND AREA LIMITATIONS
6. FIRE RESISTANCE REQUIREMENTS
NOTE: ALL STRUCTURAL MEMBERS IN RATED ENCLOSURES WILL BE RATED TO MATCH.
7. EGRESS ANALYSIS: MAXIMUM TRAVEL DISTANCES: FULLY-SPRINKLERED BUILDING
8. MINUMUM STAIR WIDTH
9. MINIMUM DOOR WIDTH
10. MINIMUM CORRIDOR WIDTH
11. FIRE EXTINGUISHERS
GENERAL INFORMATION
REFERENCES
1 : 200G-004A-201
LIFE SAFETY PLAN - FIRST FLOOR1
1 : 200G-004A-201
LIFE SAFETY PLAN - SECOND FLOOR2
1 : 200G-004A-201
LIFE SAFETY PLAN - THIRD FLOOR3
FOR INFORMATION ONLY
P-7P-5
P-5 P-5 P-5
P-5
P-5
P-7P-5
P-5 P-5 P-5
P-5
P-5
P-7 P-5
P-5 P-5 P-5
P-5
P-5
P-23
P-1
P-5
P-1
P-1
P-1
P-17
P-1
P-1
P-1
P-1
P-23
P-1
P-1
1. FIRE RATED CONSTRUCTION SHOULD EXTEND 3M (10FT) BEYOND THE FIRE
RATED ENCLOSURE AT THE STAIRWELLS.
2. ASSEMBLY AREAS CALCULATED AS THE DIFFERENCE BETWEEN THE
OVERALL OCCUPANCY MINUS THE OCCUPANCY OF THE INDIVIDUAL UNITS.
NOTES:
APARTMENT
II-B
1ST FLOOR
2ND FLOOR
3RD FLOOR
1ST FLOOR
2ND FLOOR
3RD FLOOR
APARTMENT
ASSEMBLY
MAXIMUM
FOUR (4) STORIES
18.29 M (60 FEET)
6968 SQM (75,000 SQFT)
STRUCTURAL FRAME
BEARING WALLS EXTERIOR
BEARING WALLS INTERIOR
ROOF CONSTRUCTION
FLOOR CONSTRUCTION-
INCLUDING SUPPORTING
BEAMS AND JOISTS
CORRIDOR/GUEST ROOM WALL
GUEST ROOM/GUEST ROOM WALL
GUEST ROOM/GUEST ROOM FLOOR
BOILER AND FUEL-FIRE HEATER
ROOMS SERVING MORE THAN A
SINGLE DWELLING UNIT
SHAFT ENCLOSURES (<4 STORIES)
STAIRWAY ENCLOSURES (<4 STORIES)
WITHIN DWELLING UNIT
FROM DWELLING UNIT TO EXIT
COMMON PATH OF TRAVEL
DEAD END CORRIDORS
1120 MM (44 INCHES)
810 MM (32 INCHES)
1120 MM (44 INCHES)
10LB ABC TYPE FIRE EXTINGUISHERS WILL BE
USED IN NON-HAZARDOUS AREAS (TYP.) @
EVERY 75FT (MIN. 3 PER FLOOR). 20LB ABC TYPE
FIRE EXTINGUISHERS WILL BE USED IN
ELECTRICAL AND MECHANICAL ROOMS.
R-2
NON-COMBUSTIBLE
984 SQM (10,588 SF)
984 SQM (10,588 SF)
984 SQM (10,588 SF)
66 PERSONS
66 PERSONS
66 PERSONS
18.6 SQM/PERSON (200 SF/PERSON)
1.4 SQM/PERSON (15 SF/PERSON) NET
ACTUAL
THREE (3) STORIES
17.49 M (57.39 FEET)
984 SQM (10,588 SF)
0 HR
0 HR
0 HR
0 HR
0 HR
1/2 HR
1/2 HR
1/2 HR
1 HR
1 HR
1 HR
38.10 M (125 FT)
60.96 M (200 FT)
15.24 M (50 FT)
15.24 M (50 FT)
NATIONAL ELECTRIC CODE / 2011 EDITION
THE INTERNATIONAL BUILDING CODE / 2009 EDITION
INTERNATIONAL PLUMBING CODE
AIR FORCE UNACCOMPANIED HOUSING DESIGN
GUIDE / 2006 PUBLICATION
NFPA 101 3.3.32.3
602 IBC
TABLE 7.3.1.2 NFPA 101
TABLE 7.3.1.2 NFPA 101
TABLE 503 IBC
TABLE 601 IBC
TABLE 601 IBC
TABLE 601 IBC
TABLE 601 IBC
TABLE 601 IBC
NFPA 101 30.3.6.1.2
NFPA 101 30.3.7.2
NFPA 101 30.3.7.2
NFPA 101 30.3.2.1.1
NFPA 101 8.6.5(2)
NFPA 101 7.1.3.2.1(1)
NFPA 101 30.2.6.2
NFPA 101 30.2.6.3
NFPA 101 30.2.6.4
NFPA 101 30.2.5.3.2
NFPA 101 30.2.5.4.2
NFPA 101 7.2.2.2.1.2
NFPA 101 7.2.1.2.3.2
NFPA 101 30.2.3.3
P-1
P-1
P-1 P-2
P-2
P-2
0%
D
ES
IG
N
N O
V.
, 2
AM
EN
D
M
EN
T
2 3 4 5 6 10
A
D
C
B
7 81
A-401
A-401
CORRIDOR
STORAGE
ELECTRICAL
MECHANICAL
UNIT D
UNIT E
UNIT D
UNIT D
LOBBY
UNIT D
UNIT D
CORRIDOR
LAUNDRY
JANITOR
VESTIBULE
STAIR
STAIR
VESTIBULE
VESTIBULE
UNIT D
TOILET
B.1
C.1
111 1 1
1 1
1 1
1 1
1 1
1 1 1 11
E
WALL SCONCE
RECESSED LIGHT
RECESSED CAN LIGHT
FLOURESCENT LIGHT
EXTERIOR LIGHT
EMERGENCY LIGHT
REFLECTED CEILING PLAN LEGEND
1. ALL CEILING HEIGHTS ARE FROM FINISHED FLR.
2. ALL CEILING FINISHES ARE GYPSUM BOARD U.N.O.
3. ALL CEILING FINISHES IN BATHROOMS WILL BE M.R.GWB.
4. REF. ENLARGED UNIT PLANS FOR REFLECTED CEILING PLANS
OF EACH UNIT TYPE.
5. POWER TO EXTERIOR LIGHTS MUST BE CONCEALED. SURFACE
MOUNTED CONDUIT IS NOT PERMITTED.
6. 208 LUX (20 FOOT-CANDLE) REQUIRED FOR CORRIDORS.
7. REF. CID PACKAGE FOR LIGHTING FIXTURE TYPE & LOCATION.
8. REF. SPECIFICATIONS FOR ACCESS PANEL REQUIREMENTS.
REFLECTED CEILING PLAN GENERAL NOTES
CEILING HEIGHT AT 2440MM A.F.F.
CEILING HEIGHT AT 2590MM A.F.F.
CEILING HEIGHT AT 2740MM A.F.F.
CEILING HEIGHT AT 2820MM A.F.F.
CEILING HEIGHT AT 3350MM A.F.F.
EXPOSED STRUCTURE
WALL MTD. LT. LOCATED ON THE LANDING BETWEEN THE
FIRST AND SECOND FLR. LT. IS MTD. @ 1800MM O.C. A.F.F.
WALL MTD. LT. LOCATED ON THE LANDING BETWEEN THE
SECOND AND THIRD FLR. LT. IS MTD. @ 1800MM O.C. A.F.F
CEILING MOUNTED 560MM X 915MM ATTIC ACCESS PANEL
REFLECTED CEILING PLAN KEY NOTES
EXIT LIGHT
600MM X 600MM ACOUSTICAL
CEILING GRID
GYPSUM BOARD CEILING
INSULATED METAL PANEL
US Army Corps of Engineers New York District
SY
M
BO
L
R
EV
IS
IO
N D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
D
AT
E:
SC
A L
E:
D R
A W
IN
G C
O D
E :
D
ES
IG
N
ED
B
Y:
D R
A W N
B Y :
C H
E C
KE
D B
Y:
IS
S U
E D
AT
E:
D
AT
E:
EN
G
IN
EE
R
AR
C H
IT
EC
T N
AM
E
PR
O
JE
C
T
EN
G
IN
EE
R
A R
C H
IT
EC
T
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
C O
R
PS
O F
EN
G
IN
EE
R S
N
EW
Y O
R K
D
IS
TR
IC
T, N
Y
SHEET
REFERENCE
NUMBER:
DATE:
FILE PATH: C:\Users\e3endnmw\Documents\ARCH_FY13_REVISED_E3ENDNMW.rvt
1/8/2013 5:23:55 PM
A-105
N W
N W
M J
FY
D
O R
M
IT
O R
Y, TH
U
LE
A
FB
, G R
EE
N
LA
N
D
R
EF
LE
C
TE
D
C
EI
LI
N
G
PL
AN
FI
R
ST
F
LO
O
R
1 : 100A-105A-201
REFLECTED CEILING PLAN - FIRST FLOOR1
0 5,000MM 10,000MM
SCALE 1:100 (MILLIMETERS)
0%
D
ES
IG
N
N O
V.
, 2
AM
EN
D
M
EN
D
C
B
7 81
CORRIDOR
MECHANICAL
UNIT D
UNIT E
UNIT D
UNIT D
UNIT D
UNIT D
CORRIDOR
LAUNDRY
JANITOR
STAIR 216
UNIT D
STAIR
COMMON AREA
TOILET
ELECTRICAL
B.1
C.1
111 1
1 1
1 1
1 11
1 1
1 1 1 11
1 1
E
A-515
SIM.
WALL SCONCE
RECESSED LIGHT
RECESSED CAN LIGHT
FLOURESCENT LIGHT
EXTERIOR LIGHT
EMERGENCY LIGHT
REFLECTED CEILING PLAN LEGEND
1. ALL CEILING HEIGHTS ARE FROM FINISHED FLR.
2. ALL CEILING FINISHES ARE GYPSUM BOARD U.N.O.
3. ALL CEILING FINISHES IN BATHROOMS WILL BE M.R.GWB.
4. REF. ENLARGED UNIT PLANS FOR REFLECTED CEILING PLANS
OF EACH UNIT TYPE.
5. POWER TO EXTERIOR LIGHTS MUST BE CONCEALED. SURFACE
MOUNTED CONDUIT IS NOT PERMITTED.
6. 208 LUX (20 FOOT-CANDLE) REQUIRED FOR CORRIDORS.
7. REF. CID PACKAGE FOR LIGHTING FIXTURE TYPE & LOCATION.
8. REF. SPECIFICATIONS FOR ACCESS PANEL REQUIREMENTS.
REFLECTED CEILING PLAN GENERAL NOTES
CEILING HEIGHT AT 2440MM A.F.F.
CEILING HEIGHT AT 2590MM A.F.F.
CEILING HEIGHT AT 2740MM A.F.F.
CEILING HEIGHT AT 2820MM A.F.F.
CEILING HEIGHT AT 3350MM A.F.F.
EXPOSED STRUCTURE
WALL MTD. LT. LOCATED ON THE LANDING BETWEEN THE
FIRST AND SECOND FLR. LT. IS MTD. @ 1800MM O.C. A.F.F.
WALL MTD. LT. LOCATED ON THE LANDING BETWEEN THE
SECOND AND THIRD FLR. LT. IS MTD. @ 1800MM O.C. A.F.F
CEILING MOUNTED 560MM X 915MM ATTIC ACCESS PANEL
REFLECTED CEILING PLAN KEY NOTES
EXIT LIGHT
600MM X 600MM ACOUSTICAL
CEILING GRID
GYPSUM BOARD CEILING
INSULATED METAL PANEL
US Army Corps of Engineers New York District
SY
M
BO
L
R
EV
IS
IO
N D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
D
AT
E:
SC
A L
E:
D R
A W
IN
G C
O D
E :
D
ES
IG
N
ED
B
Y:
D R
A W N
B Y :
C H
E C
KE
D B
Y:
IS
S U
E D
AT
E:
D
AT
E:
EN
G
IN
EE
R
AR
C H
IT
EC
T N
AM
E
PR
O
JE
C
T
EN
G
IN
EE
R
A R
C H
IT
EC
T
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
C O
R
PS
O F
EN
G
IN
EE
R S
N
EW
Y O
R K
D
IS
TR
IC
T, N
Y
SHEET
REFERENCE
NUMBER:
DATE:
FILE PATH: C:\Users\e3endnmw\Documents\ARCH_FY13_REVISED_E3ENDNMW.rvt
1/8/2013 5:23:56 PM
A-106
N W
N W
M J
FY
D
O R
M
IT
O R
Y, TH
U
LE
A
FB
, G R
EE
N
LA
N
D
R
EF
LE
C
TE
D
C
EI
LI
N
G
PL
AN
SE
C
O N
D F
LO
O
R
1 : 100A-106A-201
REFLECTED CEILING PLAN - SECOND FLOOR1
N
TRUE NORTH
WIND
PLAN NORTH
0 5,000MM 10,000MM
SCALE 1:100 (MILLIMETERS)
0%
D
ES
IG
N
N O
V.
, 2
AM
EN
D
M
EN
D
C
B
7 81
CORRIDOR
MECHANICAL
UNIT D
UNIT E
UNIT D
UNIT D
UNIT D
UNIT D
CORRIDOR
STAIR
UNIT D
STAIR
ELECTRICAL
COMMON AREA
TOILET
B.1
C.1
LAUNDRY
JANITOR
111 1
1 1
1 1
1 11
1 1
1 1 1 11
1 1
E
A-515
SIM.
WALL SCONCE
RECESSED LIGHT
RECESSED CAN LIGHT
FLOURESCENT LIGHT
EXTERIOR LIGHT
EMERGENCY LIGHT
REFLECTED CEILING PLAN LEGEND
1. ALL CEILING HEIGHTS ARE FROM FINISHED FLR.
2. ALL CEILING FINISHES ARE GYPSUM BOARD U.N.O.
3. ALL CEILING FINISHES IN BATHROOMS WILL BE M.R.GWB.
4. REF. ENLARGED UNIT PLANS FOR REFLECTED CEILING PLANS
OF EACH UNIT TYPE.
5. POWER TO EXTERIOR LIGHTS MUST BE CONCEALED. SURFACE
MOUNTED CONDUIT IS NOT PERMITTED.
6. 208 LUX (20 FOOT-CANDLE) REQUIRED FOR CORRIDORS.
7. REF. CID PACKAGE FOR LIGHTING FIXTURE TYPE & LOCATION.
8. REF. SPECIFICATIONS FOR ACCESS PANEL REQUIREMENTS.
REFLECTED CEILING PLAN GENERAL NOTES
CEILING HEIGHT AT 2440MM A.F.F.
CEILING HEIGHT AT 2590MM A.F.F.
CEILING HEIGHT AT 2740MM A.F.F.
CEILING HEIGHT AT 2820MM A.F.F.
CEILING HEIGHT AT 3350MM A.F.F.
EXPOSED STRUCTURE
WALL MTD. LT. LOCATED ON THE LANDING BETWEEN THE
FIRST AND SECOND FLR. LT. IS MTD. @ 1800MM O.C. A.F.F.
WALL MTD. LT. LOCATED ON THE LANDING BETWEEN THE
SECOND AND THIRD FLR. LT. IS MTD. @ 1800MM O.C. A.F.F
CEILING MOUNTED 560MM X 915MM ATTIC ACCESS PANEL
REFLECTED CEILING PLAN KEY NOTES
EXIT LIGHT
600MM X 600MM ACOUSTICAL
CEILING GRID
GYPSUM BOARD CEILING
INSULATED METAL PANEL
US Army Corps of Engineers New York District
SY
M
BO
L
R
EV
IS
IO
N D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
D
AT
E:
SC
A L
E:
D R
A W
IN
G C
O D
E :
D
ES
IG
N
ED
B
Y:
D R
A W N
B Y :
C H
E C
KE
D B
Y:
IS
S U
E D
AT
E:
D
AT
E:
EN
G
IN
EE
R
AR
C H
IT
EC
T N
AM
E
PR
O
JE
C
T
EN
G
IN
EE
R
A R
C H
IT
EC
T
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
C O
R
PS
O F
EN
G
IN
EE
R S
N
EW
Y O
R K
D
IS
TR
IC
T, N
Y
SHEET
REFERENCE
NUMBER:
DATE:
FILE PATH: C:\Users\e3endnmw\Documents\ARCH_FY13_REVISED_E3ENDNMW.rvt
1/8/2013 5:23:57 PM
A-107
N W
N W
M J
FY
D
O R
M
IT
O R
Y, TH
U
LE
A
FB
, G R
EE
N
LA
N
D
R
EF
LE
C
TE
D
C
EI
LI
N
G
PL
AN
TH
IR
D F
LO
O
R
1 : 100A-107A-201
REFLECTED CEILING PLAN - THIRD FLOOR1
N
TRUE NORTH
WIND
PLAN NORTH
0 5,000MM 10,000MM
SCALE 1:100 (MILLIMETERS)
0%
D
ES
IG
N
N O
V.
, 2
AM
EN
D
M
EN
97 8
ML
I-402
I-402 17
I-4029
I-402
I-402
3416 3260
3416 3260
1730 1530 251 3380 3036
D1 D2
D3
D4 D5
D
D6
D7 D8
A
A AA
G
G
G
A
A
C
A
G
A
ML
BEDROOM BEDROOMLIVING AREA LIVING AREA
KITCHEN
/ ENTRY
BATHROOM CLOSET BATHROOMCLOSET
73.5
1 1 1
22 2 23
333 3
A
B
2 2
4 5 6
A
B
I-403
A
AA A
A
A
G
BC B C
E3
E2
E1
E5
299 3180 3647 1645
E8
E7
E9
E11
E12
E
E10
AG
A
I-4033
I-403 7
I-403
E6 B
14 12
I-403
I-403
1686 1390 6604 4180
ML
ML
E4
A-507
A-507
A-509
A-509
B
1 RECESSED LIGHT
RECESSED CAN LIGHT
REFLECTED CEILING PLAN LEGEND
1. ALL CEILING HEIGHTS ARE FROM FINISHED FLR.
2. ALL CEILING FINISHES ARE GYPSUM BOARD U.N.O.
3. ALL CEILING FINISHES IN BATHROOMS WILL BE M.R.GWB.
4. REF. REFLECTED CEILING PLANS FOR CORRIDORS AND MAIN
SPACES.
5. REF. CID PACKAGE FOR LIGHTING FIXTURE TYPE & LOCATION.
REFLECTED CEILING PLAN GENERAL NOTES
CEILING HEIGHT AT 2440MM A.F.F.
CEILING HEIGHT AT 2590MM A.F.F.
CEILING HEIGHT AT 2740MM A.F.F.
CEILING HEIGHT AT 2820MM A.F.F.
REFLECTED CEILING PLAN KEY NOTES
GYPSUM BOARD CEILING
600MM X 600MM ACOUSTICAL
CEILING GRID
US Army Corps of Engineers New York District
SY
M
BO
L
R
EV
IS
IO
N D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
D
AT
E:
SC
A L
E:
D R
A W
IN
G C
O D
E :
D
ES
IG
N
ED
B
Y:
D R
A W N
B Y :
C H
E C
KE
D B
Y:
IS
S U
E D
AT
E:
D
AT
E:
EN
G
IN
EE
R
AR
C H
IT
EC
T N
AM
E
PR
O
JE
C
T
EN
G
IN
EE
R
A R
C H
IT
EC
T
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
C O
R
PS
O F
EN
G
IN
EE
R S
N
EW
Y O
R K
D
IS
TR
IC
T, N
Y
SHEET
REFERENCE
NUMBER:
DATE:
FILE PATH: C:\Users\e3endnmw\Documents\ARCH_FY13_REVISED_E3ENDNMW.rvt
1/8/2013 5:10:10 PM
A-401
N W
N W
M J
FY
D
O R
M
IT
O R
Y, TH
U
LE
A
FB
, G R
EE
N
LA
N
D
EN
LA
R G
ED
P
LA
N
R
C P
- D
E U
N
IT
S
1 : 50A-401A-101
UNIT D ENLARGED PLAN1
1 : 50A-401A-105
UNIT D ENLARGED RCP2
1 : 50A-401A-105
UNIT E ENLARGED RCP3
1 : 50A-401A-101
UNIT E ENLARGED PLAN4
N
TRUE NORTH
WIND
PLAN NORTH 0 1,250MM 2,500MM
SCALE 1:50 (MILLIMETERS)
0%
D
ES
IG
N
N O
V.
, 2
2 2
AM
EN
D
M
EN
6 7
MECHANICAL
STORAGE
ELECTRICAL
LOBBY
VESTIBULE
TOILET
C
G
B
A
I-401
I-401
2256 2015 2895 4127
C
GYM AREA
A-508
A-508
A-509
G
G
A
A
G
A
A
GYM
ENCLOSURE
N.I.C.
A
D
C
B
MECHANICAL
COMMON AREA
TOILET
ELECTRICAL
I-402
3 4
I-402
2456 8838
A-509
2456 1085 420 7445
2087 7582
G
C
A
A
A
G
US Army Corps of Engineers New York District
SY
M
BO
L
R
EV
IS
IO
N D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
D
AT
E:
SC
A L
E:
D R
A W
IN
G C
O D
E :
D
ES
IG
N
ED
B
Y:
D R
A W N
B Y :
C H
E C
KE
D B
Y:
IS
S U
E D
AT
E:
D
AT
E:
EN
G
IN
EE
R
AR
C H
IT
EC
T N
AM
E
PR
O
JE
C
T
EN
G
IN
EE
R
A R
C H
IT
EC
T
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
C O
R
PS
O F
EN
G
IN
EE
R S
N
EW
Y O
R K
D
IS
TR
IC
T, N
Y
SHEET
REFERENCE
NUMBER:
DATE:
FILE PATH: C:\Users\e3endnmw\Documents\ARCH_FY13_REVISED_E3ENDNMW.rvt
1/8/2013 5:10:12 PM
A-402
N W
Au th or M
J
FY
D
O R
M
IT
O R
Y, TH
U
LE
A
FB
, G R
EE
N
LA
N
D
EN
LA
R G
ED
P
LA
N
LO
BB
Y
C
O M
M O
N
AR
EA
1 : 50A-402A-101
ENLARGED PLAN - LOBBY AREA1
1 : 50A-402A-102
ENLARGED PLAN - COMMON AREA2
0 1,250MM 2,500MM
SCALE 1:50 (MILLIMETERS)
N
TRUE NORTH
WIND
PLAN NORTH
0%
D
ES
IG
N
N O
V.
, 2
AM
EN
D
M
EN
9.01
9.07
9.08
9.04
5.12
R
EF
ER
T O
R
EF
LE
C
TE
D
C
EI
LI
N
G
PL
AN
F
O R
C
EI
LI
N
G H
EI
G
H T
AB
O
VE
H
IG
H
ES
T
M
IN
C
EI
LI
N
G
9.04
9.08
9.07
9.25
9.11
5.12
5.12
7.25
R
EF
ER
T
O R
EF
LE
C
TE
D C
EI
LI
N G
PL
AN
F O
R C
EI
LI
N G
H
EI
G H
T
R
EF
ER
T
O R
EF
LE
C
TE
D C
EI
LI
N G
P
LA
N
FO
R C
EI
LI
N G
H
EI
G H
T
13 95 13
WALL
UL RATING: U411 (EQUIVALENT)
NGC 2288: STC 53 (EQUIVALENT)
2HR. RATED
5.12
9.25
9.07
9.08
9.04
7.25
139513
R
EF
ER
T
O R
EF
LE
C
TE
D C
EI
LI
N G
PL
AN
F O
R C
EI
LI
N G
H
EI
G H
T
WALL
UL RATING: U411 (EQUIVALENT)
NGC 2288: STC 53 (EQUIVALENT)
2HR. RATED
R
EF
ER
T
O R
EF
LE
C
TE
D C
EI
LI
N G
PL
AN
F O
R C
EI
LI
N G
H
EI
G H
T
5.12
9.25
9.07
9.08
9.04
9.02 7.25
139513
R
EF
ER
T
O R
EF
LE
C
TE
D C
EI
LI
N G
P
LA
N
FO
R C
EI
LI
N G
H
EI
G H
T
R
EF
ER
T
O R
EF
LE
C
TE
D C
EI
LI
N G
PL
AN
F O
R C
EI
LI
N G
H
EI
G H
T
2HR. RATED WALL
UL RATING: U420 (EQUIVALENT)
RAL-TL-76-156: STC 57 (EQUIVALENT)
95VARIES
R
EF
ER
T
O R
EF
LE
C
TE
D C
EI
LI
N G
P
LA
N
FO
R C
EI
LI
N G
H
EI
G H
T
R
EF
ER
T
O R
EF
LE
C
TE
D C
EI
LI
N G
PL
AN
F O
R C
EI
LI
N G
H
EI
G H
T
1HR. RATED WALL
5.12
9.11
9.12
9.07
9.08
9.04
5.12
15013 13
UL RATING: U407 (EQUIVALENT)
ENCASE ELECTRICAL PANELS AND FIRE EXTINGUISHER
CABINETS IN 2 LAYERS OF GYP TO MAINTAIN FIRE RATING
KEYED NOTES
30MM METAL DECK INSTALLED PERPENDICULAR TO DECK
BELOW. REF. STRUCTURAL.
200MM COLD FORM METAL "C" JOIST SUSPENDED FROM
STRUCTURE @ 1800MM O.C.
50MM RIGID MINERAL FIBER FLOOR INSULATION.
CONTINUOUS 89MM THICK MINERAL-FIBER BATT INSULATION
FRICTION-FIT BETWEEN STUDS.
95MM METAL STUD WALL WITH (2) LAYERS OF TYPE "X" 13MM
GYPSUM BOARD ON BOTH SIDES.
(1) 19MM GYPSUM BOARD OVER (2) LAYERS OF 13MM GYPSUM
BOARD.
(1) LAYER OF 13MM GYPSUM BOARD INSTALLED PERPENDICULAR
TO METAL DECK BELOW.
(2) LAYERS OF SUSPENDED 13MM GYPSUM BOARD CEILING
ATTACHED TO 45MM METAL HAT CHANNELS AT 400MM O.C.
FINISHED FLOOR. REF. CID PACKAGE UNDER SEPARATE COVER.
FINISHED WALL. REF. CID PACKAGE UNDER SEPARATE COVER.
(2) LAYERS OF 13MM TYPE "X" GYPSUM BOARD ATTACHED TO
THE UNDERSIDE OF DECKING AND EXTENDED A MINIMUM OF
300MM PAST THE CORRIDOR WALLS INTO THE UNITS.
150MM METAL STUD WALL WITH (2) LAYERS OF 13MM TYPE "X"
GYPSUM BOARD ON BOTH SIDES.
95MM METAL STUD WALL WITH (2) LAYERS OF 13MM TYPE "X"
GYPSUM BOARD ON BOTH SIDES OF METAL STUD TO THE
UNDERSIDE OF DECKING.
(2) 95MM METAL STUD WALLS WITH (2) LAYERS OF 13MM TYPE "X"
GYPSUM BOARD OUTER SIDES OF METALS STUDS TO
UNDERSIDE OF DECKING.
5.12
7.25
9.01
9.04
9.07
9.08
9.11
9.12
9.25
9.26
5.03
7.03
9.02
9.03
PARTITION TYPE NOTES:
1. NGC REFERS TO THE NATIONAL GYPSUM COMPANY
2. STC REFERS TO SOUND TRANSMISSION CLASS AS PER AMERICAN
SOCIETY FOR TESTING AND MATERIALS PROCEDURES (ASTM).
3. UL REFERS TO UNDERWRITERS LABORATORIES INC.
4. RAL REFERS TO RIVERBANK ACOUSITCAL LABORATORIES
US Army Corps of Engineers New York District
SY
M
BO
L
R
EV
IS
IO
N D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
D
AT
E:
SC
A L
E:
D R
A W
IN
G C
O D
E :
D
ES
IG
N
ED
B
Y:
D R
A W N
B Y :
C H
E C
KE
D B
Y:
IS
S U
E D
AT
E:
D
AT
E:
EN
G
IN
EE
R
AR
C H
IT
EC
T N
AM
E
PR
O
JE
C
T
EN
G
IN
EE
R
A R
C H
IT
EC
T
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
C O
R
PS
O F
EN
G
IN
EE
R S
N
EW
Y O
R K
D
IS
TR
IC
T, N
Y
SHEET
REFERENCE
NUMBER:
DATE:
FILE PATH: C:\Users\e3endnmw\Documents\ARCH_FY13_REVISED_E3ENDNMW.rvt
1/8/2013 5:10:12 PM
A-510
N W
/C S
N W
M J
FY
D
O R
M
IT
O R
Y, TH
U
LE
A
FB
, G R
EE
N
LA
N
D
PA
R
TI
TI
O N
T
YP
ES
0 250MM 500MM
SCALE 1:5 (MILLIMETERS)
1 : 5A-510
PARTITION TYPE A1
1 : 5A-510
PARTITION TYPE B2
1 : 5A-510
PARTITION TYPE D4
1 : 5A-510
PARTITION TYPE G5
0%
D
ES
IG
N
N O
V.
, 2
1 : 5A-510
PARTITION TYPE C3
AM
EN
D
M
EN
4" MAX
STRINGER
PREPRINTED ON VER. PIPE RAIL @ LOC. IND.
CABLES PASS THROUGH 12MM DIA. HOLES
WIRE CLAMP TYP. EACH CONNECTION
AS SHOWN
TENSION CABLE SPACED
VERTICAL POSTS IS 1200MM O.C.
MAXIMUM SPAN BETWEEN
RAIL AND VERTICALS
50MM DIA. PIPE RAIL @ TOP
TURN BUCKLE TYP. EACH CABLE
LINE
FLOOR
EQ10
EQ
EQ
EQ
EQ
EQ
EQ
LINE
FLOOR
LOADING.
MAINTAIN REQUIRED HANDRAIL
BLOCKING TO SPAN SOLIDLY
BETWEEN MTL. STUDS TO
IN MTL. STUD AND GWB WALL
SOLID BLOCKING CONCEALED
DOTTED LINES REPRESENT
TOP OF
STRINGER
CHANNEL
POSTS @ CENTER RAIL
O.C. MAX. WALL SUPPORTS
SUPPORTED @ 1200MM
WALL MOUNTED
38MM DIA. PIPE RAIL
STRINGER
BOTTOM OF CHANNEL
TREAD STAIR
METAL PAN CONC.
RUN IS SIMILAR
TOP OF STAIR
BLOCKING AT
RETURN TO
HANDRAIL TO
WALL (TYP).
TREAD WIDTH
9.10
5.06
9.08
9.19
9.07
9.04
5.12
9.21
5.05
5.14
9.07
9.21
9.04
5.12
5.27
5.26
50MM DIA. VERTICAL PIPE RAIL. RAIL TO HAVE 10MM DIA. HALF RING WELDS TO RECEIVE CABLE.5.27
5.26 6MM DIA. CABLE WITH CABLE ELBOW AT RING CONNECTION.
KEYED NOTES:
FINISHED FLOOR. RE: CID PACKAGE UNDER SEPARATE COVER.9.07
9.19 RUBBER BASE. RE: CID PACKAGE UNDER SEPARATE COVER
9.08 FINISHED WALL. RE: CID PACKAGE UNDER SEPARATE COVER.
5.14 STEEL FRAMED STAIRS WITH CONCRETE FILLED TREADS AND LANDINGS.
STEEL BEAM. RE: STRUCTURAL.5.06
9.10 (2) LAYERS OF 13MM GYPSUM BOARD OVER 50MM 'Z' CHANNEL PLACED HORIZONTALLY
@ 400MM O.C. WITH 50MM BATT INSULATION OVER (1) LAYER OF 13MM GYPSUM BOARD
OVER 45MM HAT CHANNEL PLACED VERTICALLY @ 400MM O.C.
9.04 (2) LAYERS OF SUSPENDED 13MM GYPSUM BOARD CEILING ATTACHED TO 45MM METAL HAT
CHANNELS AT 400MM O.C.
5.12 200MM COLD FROM METAL "C" JOIST SUSPENDED FROM STRUCTURE @ 1800 MM O.C.
9.21 "Z" REVEAL MOULDING. FLANGE OF "Z" REVEAL IS TO BE
FASTENED TO THE SURFACE OF THE DRYWALL. FASTENERS WILL BE CONCEALED AND
FEATHERED WITH DRYWALL COMPOUND AND TAPE.
5.05 STEEL COLUMN. RE: STRUCTURAL.
TYP.
A-524
280 280
M
IN
305 280
M
IN
280 280
US Army Corps of Engineers New York District
SY
M
BO
L
R
EV
IS
IO
N D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
D
AT
E:
SC
A L
E:
D R
A W
IN
G C
O D
E :
D
ES
IG
N
ED
B
Y:
D R
A W N
B Y :
C H
E C
KE
D B
Y:
IS
S U
E D
AT
E:
D
AT
E:
EN
G
IN
EE
R
AR
C H
IT
EC
T N
AM
E
PR
O
JE
C
T
EN
G
IN
EE
R
A R
C H
IT
EC
T
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
C O
R
PS
O F
EN
G
IN
EE
R S
N
EW
Y O
R K
D
IS
TR
IC
T, N
Y
SHEET
REFERENCE
NUMBER:
DATE:
FILE PATH: C:\Users\e3endnmw\Documents\ARCH_FY13_REVISED_E3ENDNMW.rvt
1/8/2013 5:10:13 PM
A-524
N W
N W
M J
FY
D
O R
M
IT
O R
Y, TH
U
LE
A
FB
, G R
EE
N
LA
N
D
ST
AI
R D
ET
AI
LS
0 250MM 500MM
SCALE 1:5 (MILLIMETERS)
NTSA-524A-305
RAILING ELEVATION1
NTSA-524A-305
OUTSIDE WALL HANDRAIL ELEVATION2
1 : 5A-524A-504
STAIR LANDING DETAIL3
1 : 5A-524A-504
STAIR LANDING DETAIL4
NTSA-524A-524
TENSION CABLE DETAIL5
0%
D
ES
IG
N
N O
V.
, 2
AM
EN
D
M
EN
T
1 : 5A-524
HANDRAIL RETURN AT BOTTOM TREAD9
1 : 5A-524
HANDRAIL RETURN AT TOP TREAD6
1 : 5A-524
HANDRAIL RETURN GUARDRAIL BOTTOM7
(BACKSPLASH)
S W
IT
C H S E
N S
O R
W A L L
P
H O
N E
T E L E P
H O
N E
P O
W E R
PLANE
FLOOR
TYPICAL MOUNTING HEIGHTS
(NOT TO SCALE)
C A R
D
R E
A D E R K E
Y P
A D
4"
VOICEDATA
BLANKBLANK
S
SINK COUNTER
PLANE
DROPPED CEILING
B O
X E S
J U
N C T
IO
N
P D
E
C
J W
C S
N S
A
S
IP
R N E T
L O
C K B
O X E S
D A T
A V
O
IP
C
A T
V
INSTRUCTIONS.
SHALL BE INSTALLED PER MFR
ALL CEILING MOUNTED EXIT SIGNS
18"(458MM)
~100MM
M M
M M
M M
(COORDINATE WITH ARCH)
2" (50MM) ABOVE BACKSPLASH
REFRIGERATOR
M M
E-002
E L E
C T
R
IC
A L N
O T
E S
ARCHITECTURAL THEME.
BE DRESSED IN A DECORATIVE FINISH IN ACCORDANCE WITH THE SURROUNDING
3. PANELBOARD SURFACES, WHERE INSTALLED IN PUBLIC/ACCESSIBLE HALLWAY, SHALL
APPROVAL PRIOR TO MATERIAL PROCUREMENT.
ARCHITECTURAL THEME. PROVIDE SHOP DRAWINGS FOR GOVERNMENT REVIEW AND
THE GOVERNMENT (COR), ALL EXPOSED FINISHES SHALL MATCH WITH THE SURROUNDING
IN SITUATION WHERE EXPOSED INSTALLATION IS DEEMED NECESSARY, AND APPROVED BY
2. ALL INSTALLATION SHALL BE CONCEALED BEHIND WALLS OR IN ABOVE CEILING VOID.
REVIEW AND APPROVAL PRIOR TO PROCUREMENT.
SHALL BE IVORY. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR GOVERNMENT
ARCHITECTURAL THEME IN THE SURROUNDING. STANDARD FACEPLATES COLOR
1. RECEPTACLE AND SWITCH FACEPLATE SHALL BE IN ACCORDANCE WITH THE
INTERIOR ELECTRICAL FINISHING NOTES:
AND DIMMING EQUIPMENT).
COMPRISED OF FIXTURES, LAMPS, SWITCHES BALLASTS, OCCUPANCY SENSORS
(ONE EXAMPLE OF AN ELECTRICAL SYSTEM IS THE BUILDING LIGHTING SYSTEM
MANUFACTURERS FOR USE WITH ALL OTHER COMPONENTS WITHIN THE SYSTEM.
COMPATIBLE WITH ONE ANOTHER AND SHALL BE APPROVED BY THE VARIOUS
24. COMPONENTS WHICH CONSTITUTE AN ELECTRICAL SYSTEM SHALL BE FULLY
2#12, 1#12G IN 1/2" C UNLESS OTHERWISE INDICATED.
23. CONNECT MOTORIZED DAMPERS TO CORRESPONDING MOTOR CIRCUIT WITH
ROUGHING IN.
EQUIPMENT WITH EQUIPMENT SUPPLIERS’ ROUGH-IN DRAWINGS BEFORE
22. VERIFY EXACT LOCATION OF ALL OUTLETS AND BOXES SERVING KITCHEN
WITH OTHER TRADES TO ASSURE ELECTRIC OUTLETS ARE CONCEALED.
21. COORDINATE HEIGHT AND LOCATION OF ELECTRIC WATER COOLER OUTLETS
CONDUIT WINDOWS CONFIGURED FOR THE EQUIPMENT.
EXTEND 6-INCHES BEYOND EQUIPMENT ON ALL SIDES. PADS SHALL INCLUDE
4-INCH THICK REINFORCED CONCRETE WITH CHAMFERED EDGES. PADS SHALL
TRANSFORMERS SHALL BE MOUNTED ON HOUSEKEEPING PADS. PADS SHALL BE
20. ALL MAJOR FLOOR MOUNTED EQUIPMENT SUCH AS SWITCHBOARDS, AND
PRIOR TO COORDINATION.
INSTALLED BY OTHER TRADES. NO ELECTRICAL EQUIPMENT SHALL BE ROUGHED-IN
RELAY CABINETS SHALL BE COORDINATED WITH THE LAYOUT OF EQUIPMENT TO BE
EQUIPMENT INCLUDING TRANSFORMERS, POWER PANELS, CONTROL PANELS AND
FOR ACTUAL EQUIPMENT SELECTED PRIOR TO ROUGHING-IN EQUIPMENT ELECTRICAL
19. VERIFY ELECTRICAL EQUIPMENT DIMENSIONS AND LAY-OUT ELECTRICAL ROOMS
GENERAL NOTES: (CONTINUED)
REFER TO MANUFACTURER INSTRUCTION FOR INSTALLATION REQUIREMENT.
OCCUPANCY SENSORS AND DAYLIGHTING CONTROLS SHALL BE FULLY COMPATIBLE.
10. FOR LED FIXTURES, DIMMING DRIVERS, DIMMING SWITCHES,
OCCUPANCY SENSORS AND DAYLIGHTING CONTROLS SHALL BE FULLY COMPATIBLE.
9. FOR FLUORESCENT FIXTURES, DIMMING BALLASTS, DIMMING SWITCHES,
ENGRAVED ’OCCUPANCY SENSOR POWER PACK’.
THE ROOM AND 4 FEET AFF. THE BOX FACEPLATE SHALL BE PERMANENTLY
8. POWER PACK BOXES SHALL BE LOCATED 6 INCHES FROM INSIDE CORNER OF
THE RECOMMENDATIONS OF THE SENSOR MANUFACTURER.
POWER PACK BOXES SHALL BE SINGLE OR DOUBLE GANG IN ACCORDANCE WITH
MOUNTED IN A RECESSED SWITCH BOX WHERE CEILING SPACE IS INACCESSIBLE.
CEILING WHERE CEILING SPACE IS ACCESSIBLE. POWER PACKS SHALL BE
7. POWER PACKS FOR OCCUPANCY SENSORS SHALL BE MOUNTED ABOVE THE
CONTROLS. SEE DWG EL-502 FOR WIRING REQUIREMENTS.
6. WIRE COUNTS ARE NOT SHOWN FOR CIRCUITS WITH OCCUPANCY SENSOR
OF OCCUPANCY SENSOR SYSTEM SHALL BE PROVIDED.
MANUFACTURER FOR COMPLETE ROOM COVERAGE. FACTORY COMMISSIONING
ACTUAL LOCATIONS AND QUANTITIES SHALL BE DETERMINED BY THE SENSOR
5. LOCATIONS AND QUANTITIES OF OCCUPANCY SENSORS ARE APPROXIMATE.
CONTAINING EXPOSED DUCTWORK AND PIPING.
4. COORDINATE EXACT LOCATION OF LIGHTS WITH OTHER TRADES IN ROOMS
START BALLAST.
3. ALL FLUORESCENT FIXTURES USED SHALL BE EQUIPPED WITH PROGRAMMED
PLATES.
ROW SHALL BE FURNISHED WITH PROPER NUMBER OF CONNECTORS AND END
WITH TWO END PLATES. FLUORESCENT FIXTURES MOUNTED IN A CONTINUOUS
2. FLUORESCENT FIXTURES MOUNTED INDEPENDENTLY SHALL BE FURNISHED
SPECIFICATION.
1. SEE DWG EL-501 FOR LIGHTING FIXTURE SCHEDULE AND EL503 FOR FIXTURE
LIGHTING NOTES:
C O
R R
ID
O R
R E C P
(1000MM)
39"
G F C I R
E C P
DRYERS
WASHERS
M M
W A S
H E R D R
Y E R
R E C P
BE NECESSARY.
EQUIPMENT. SOME ADJUSTMENTS TO THE HEIGHTS GIVEN MAY
WITH THE MANUFACTURER, AND PHYSICAL DIMENSION OF THE
MOUNTING HEIGHTS FOR APPLIANCES SHALL BE COORDINATED 2.
MOUTNING HEIGHTS ARE PROVIDED FOR REFERENCE ONLY. 1.
MOUNTING HEIGHT NOTES:
THAN 300MM X 300MM FOR ACCESS MEANS.
DIRECT ACCESS IS NOT POSSIBBLE, PROVIDE ACCESS PANELS OF SIZE NO SMALLER
THE INSTALLATION IS TO BE FLUSHED OR CONCEALED (I.E. ABOVE CEILING) AND
19. ALL INSTALLATION OF FIXTURES AND BOXES SHALL BE FULLY ACCESSIBLE. IF
WILL BE ALLOWED.
FOUNDATION WALLS. NO DRILLING OR PUNCHING THROUGH THE FOUNDATION WALLS
CONDUITS THROUGH THE FOUNDATION WALL DURING CONSTRUCTION OF THE
18. PROVIDE PIPE SLEEVES FOR POWER AND COMMUNICATION ENTRANCE AND EXIT
OF GROUNDING.
FOR THE BUILDING EXPANSION AND CONTRACTION AND TO PROVIDE FOR CONTINUITY
WITH SUITABLE EXPANSION FITTINGS OR OTHER SUITABLE MEANS TO COMPENSATE
CROSSING STRUCTURAL EXPANSION JOINTS OR SEISMIC JOINTS SHALL BE PROVIDED
CONDUITS (POWER, SIGNAL, ETC.) THAT RUN THROUGH FIRE WALLS. RACEWAYS
17. PROVIDE FIRE STOPPING IN ACCORDANCE WITH SPECIFICATIONS FOR ALL
INDICATED OTHERWISE.
16. ALL OUTLET BOXES, WIRING, ETC. SHALL BE CONCEALED UNLESS EXPLICITLY
EACH END TO INDICATE LOCATION OF OTHER END.
15. ALL EMPTY CONDUIT SHALL INCLUDE A PULL WIRE AND SHALL BE TAGGED AT
TUBING (EMT) UNLESS OTHERWISE INDICATED OR REQUIRED BY NEC.
14. CONDUIT INSIDE THE FACILITY SHALL BE INSTALLED IN ELECTRICAL METALLIC
367’151’ #8 AWG
233’101’ #10 AWG
127’62’ #12AWG
277 VOLTS120 VOLTS
PHASE CIRCUIT (ONE WAY) SHALL NOT EXCEED THE VALUES LISTED:
CIRCUIT WIRING AND SELECT WIRE SIZE ACCORDINGLY. THE LENGTH OF A SINGLE
13. CONSIDER VOLTAGE DROP WHEN DETERMINING THE EXACT ROUTING OF BRANCH
INDOOR LOCATIONS SHALL BE TYPE THHN.
GROUNDING CONDUCTOR SIZED PER THE NATIONAL ELECTRICAL CODE. WIRING IN
12. ALL BRANCH CIRCUIT WIRING SHALL INCLUDE A GREEN SOLID EQUIPMENT
" CONDUIT.4
33-#6, 1-#10G IN
LOCATED IN A SEPERATE ENCLOSURE EXTERNAL OF THE PANELBOARD. PROVIDE
11. SEE PANELBOARD SCHEDULES FOR REQUIRED TVSS UNITS. TVSS UNITS SHALL
RECOMMENDATIONS.
ACCORDANCE WITH NFPA 70 AND THE MANUFACTURES’ INSTALLATION
HOUSEKEEPING PADS. WORKING AND VENTILATION CLEARANCES SHALL BE IN
FLOOR MOUNTED DRY TYPE TRANSFORMERS SHALL BE MOUNTED ON
TRANSFORMERS FROM THE CEILING WHEN ALLOWED BY THE MANUFACTURER.
CANNOT BE FIT IN ELECTRIC ROOM, THE CONTRACTOR MAY TRAPEZE MOUNT THE
AND IN COMPLIANCE WITH NEC WORKING CLEARANCES. IF SELECTED EQUIPMENT
10. DRY TYPE TRANSFORMERS SHALL BE FLOOR MOUNTED WHERE PRACTICAL
PRESENCE OF THE COR.
USE EQUIPMENT. SETTINGS SHALL BE COORDINATED WITH AND SET IN THE
9. TRANSFORMER TAPS SHALL BE SET TO YIELD THE OPTIMAL VOLTAGE AT END
AVERAGE WINDING TEMP ERATURE RISE ABOVE A 40 DEG C AMBINENT.
PROVIDED WITH AN INSULATION SYSTEM RATED 220 DEG C AND WITH 80 DEG C
TRANSFORMER SHALL BE VACUUM PRESSURE IMPREGNATED (VPI) TYPE AND BE
AND TWO (2) 2.5 PERCENT TAPS BELOW NORMAL FULL CAPACITY. DRY TYPE
8. DRY TYPE TRANSFORMERS SHALL INCLUDE TWO (2) 2.5 PERCENT TAPS ABOVE
DRY-TYPE TRANSFORMER:
VAR, THD, PF, FREQUENCY AND REAL ENERGY (Whr).
(PF). THE DEVICES SHALL ALSO DISPLAY AND LOG MAXIMUM AND MINIMUM V, I, W,
APPARENT POWER (VA) , TOTAL HARMONIC DISTORTION (THD) AND POWER FACTOR
PHASE VOLTAGE (V) , CURRENT (I) , REAL POWER (W) , REACTIVE POWER (VAR),
7. THE PANELBOARD MONITOR AND METER DEVICES SHALL DIGITALLY DISPLAY PER
CONNECT THE METER TO THE BASEWIDE EMCS SYSTEM VIA LOCAL AREA NETWORK.
SHALL BE OF TYPE SUITABLE FOR INTERFACE WITH BASE-WIDE EMCS SYSTEM.
AS SHOWN ON DRAWINGS. THE METER SHALL BE PROVIDED WITH ETHERNET PORT AND
6. PROVIDE AND INSTALL THE FACILITY TRANSFORMER POWER AND ENERGY METER
LISTED FOR USE AS SERVICE ENTRANCE EQUIPMENT.
5. MAIN DISTRIBUTION PANELS MDP AND POWER TRANSFER SWITCH SHALL BE UL
TO MOTOR STARTERS.
SECTIONS IN THE SPECIFICATIONS, DISCONNECT SWITCHES ARE REQUIRED ADJACENT
SPECIFICATIONS. WHERE COMBINATION STARTERS ARE NOT COVERED UNDER OTHER
COMBINATION STARTERS SHALL BE FURNISHED AS SPECIFIED IN SECTIONS OF THE
4. ELECTRICAL DRAWINGS INDICATE SEPARATE DISCONNECTS AND MOTOR STARTERS.
SHALL BE AS REQUIRED BY THE NATIONAL ELECTRICAL CODE
3. MOUNTING HEIGHTS FOR SAFETY SWITCHES, MOTOR STARTERS, AND PANELBOARDS
FOR SPECIFIC LOCATIONS.
ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL CONTRACTOR
MOTORS SHOWN ON THE ELECTRICAL DRAWINGS ARE GENERAL LOCATIONS. THE
2. THE LOCATION OF EXHAUST FANS, A/C UNITS, MOTOR STARTERS, AND OTHER
SCALED, REFER TO THE ARCHITECTURAL DRAWINGS FOR DIMENSIONS.
PULL BOXES, AND OBSTRUCTIONS. THE DRAWINGS ARE NOT INTENDED TO BE
WITHIN THE SCOPE OF THE DRAWINGS TO SHOW ALL NECESSARY OFFSETS, BENDS,
BUT SUBJECT TO APPROVAL FOR VISUAL AND STRUCTURAL REASONS. IT IS NOT
OF OTHER TRADES AND STRUCTURE. SIMPLIFY INSTALLATION WHEREVER POSSIBLE,
SUCH AS FOR MECHANICAL EQUIPMENT, COORDINATE CONDUIT RUNS WITH THE WORK
SPACE WILL PERMIT. WHERE CONDUIT RUNS ARE NOT SHOWN ON THE DRAWINGS,
AS CLOSELY AS PROPER COORDINATION WITH THE WORK OF OTHER TRADES AND
THE ACTUAL ROUTES OF CONDUITS, WHERE INDICATED, THEY SHALL BE FOLLOWED
THE REQUIRED WIRING. ALTHOUGH THE DRAWINGS DO NOT NECESSARILY INDICATE
GENERAL LOCATION OF OUTLETS, EQUIPMENT, AND THE CIRCUIT ARRANGEMENT OF
1. THE ELECTRICAL DRAWINGS ARE DIAGRAMMATICAL IN NATURE AND INDICATE THE
GENERAL NOTES:
R
E V
IS
E D N
O T
E S
D
E C
A C
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R of Engineers
US Army Corps
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
C O
N T
R A
C T N
O
SHEET OF XXX
IP
S
H O
R T
D E
S
IG
N
A N
S I
D
U S
E R
N A
M E
P L
O T
T E
D B
Y
S
Y T
IM
E
F I L
M E
U S
E R
N A
M E
S u b m i t t e d b y
D D
M M
M
Y Y
Y
H
:M
M P l o t a t e
New York District
NUMBER
REFERENCE
SHEET
N E
W Y
O R
K D
IS
T R
IC
T
N Y
C O
R P
S O
F E
N G
IN
E E
R S
U S
A R
M Y E
N G
IN
E E
R D
IS
T R
IC
T F
Y D
O R
M
IT
O R
Y T
H U
L E A
F B
G R
E E
N L
A N
D N
O V
K-7
N.C. N.C.
90E
Z=5.75%
4.16KV - 120/208Y
500KVA (CUBICLE)
"XMFR-7101"
1600AT
1600AF
150AT
200AF
200AT
200AF
SPARE
K-16
120/208V, 3PH, 4W, 2000A, 60HZ, 50,000 AIC
(#01401)
K-PLANTCKT
TIE
L.A.
CLASS
STATION
9KV
BIL = 60KV
40KA Isc ASYM.
(NON-FUSED)
HVLcc CLASS
BLDG.101
DORM
TO NEW
SUBSTATION
FOR NEW
HOUSE PANEL
SPACE SPACE
-----AT
400AF
-----AT
400AF
#07101
SUBSTATION
NEW CUBICLE
ES-601
D
IS
T R
IB
U T
IO
N D
IA
G R
A M
S
IT
E E
L E
C T
R
IC
A L
SHEATH (OKOGUARD C-L-X TYPE MV-105 OR APPROVED EQUAL)
AWG #4/0 TYPE MV-105 5KV SHIELDED POWER CABLE WITH ALUMINUM 1
FEEDER NOTES
2000AT
2000AF
SEE NOTE 7
METERING
ELECTRONIC
M
3 CT’S
2000A
SECTION,
MAIN BREAKER
SECONDARY
PROVIDE APPROXIMATELY 20KW HVAC (HEATERS, 4-5KW EA.) FOR INTERIOR.5.
LIGHTING LEVEL SHALL BE 30FC 3-FT ABOVE FINISHED FLOOR.4.
LOADING AND INSTALLATION.
SUBSTATION ENCLOSURE SHALL BE EQUIPPED WITH REMOVABLE WALL SECTIONS FOR EQUIPMENT3.
GOVERNMENT REVIEW AND APPROVAL.
OF THE UNIT SUBSTATION. DIMENSION OF PACKAGED UNIT SUBSTATION SHALL BE SUBMITTAL FOR REFER TO SPECIFICATION 26 11 16 "SECONDARY WALK-IN UNIT SUBSTATION" FOR SPECIFICATION2.
STEEL GRADE SHALL BE ASTM A572, C10 OR GREATER.
ENCLOSURE SHALL BE NEMA 3R RATED, AND SHALL BE FABRICATED FROM STEEL CHANNELS.1.
SUBSTATION ENCLOSURE NOTE:
DETAIL: PACKAGED SUBSTATION RISER DIAGRAM (SEE NOTES BELOW)
BELOW)
(SEE NOTE 8
= 40kA Isc ASYM
2000A
PANEL SECTION,
DISTRIBUTION
I-LINE
D
E C
A C
SIZED PER MFR OF PACKAGED SUBSTATION
= 40kA??
Isc ASYM
90E, 360MVA
LIMITING FUSE,
WITH CURRENT
HVLcc CLASS
NOTE 10 BELOW
(SEE ES-102) SEE ALSO
RELOCATED K-16 FEEDER
EXISTING AWG #4/0 TYPE MV-105 5KV SHIELDED POWER CABLE WITH ALUMINUM SHEATH
SEE ALSO NOTE 10 BELOW
NEW FEEDER (SEE ES-102)
LOOP DISTRIBUTION
TO DOWNSTREAM K-7
ROUTING LOCATION.
7605, ETC.) SEE ES-102
(SUB. BLDG. 7102, 7608,
LOOP DISTRIBUTION
TO DOWNSTREAM K16
T-7102
SECTION
BREAKER
DISTRIBUTION
1600A
SECTION 3 SECTION 4 SECTION 5 SECTION 6SECTION 1, 2 SECTION 7
ARMOURED POWER CABLE TO NEW DORMITORY BLDG. 101
6 SETS OF 750MCM AND #4/0 GND - TYPE MC-HL 600V, XHHW-2,
BELOW
FEEDER NOTES
SEE NOTE 2 AND
SERIES DRAWINGS.
REFER TO PHASING NOTES REGARDING FEEDER INSTALLATION WORK IN DWG ES-602xx 10.
ALL ELECTRICAL EQUIPMENT SHALL BE OF SQUARE D PRODUCTS OR APPROVED EQUAL. 9.
USED AT THULE AIR BASE. COORDINATE METERING REQUIREMENT WITH THULE BCE.
MODEL OR APPROVED EQUAL, AND SHALL BE COMPATIBLE WITH THE COMMUNICATION PROTOCOL
PROVIDE ELECTRONIC METER AS SHOWN. ELECTRONIC METER SHALL BE E-MON CLASS 50008.
SWITCHBOARD SECTIONS. REFER TO SPEC SEC 26 28 01.00 10 FOR REQUIREMENTS..
PROVIDE DIGITAL ADJUSTABLE TRIP ELEMENTS FOR ALL BREAKERS IN DISTRIBUTION 7.
ARC FLASH STUDIES AND SUBSEQUENT RATING OF EQUIPMENT.
TRANSFORMERS SHALL BE USED FOR FAULT CURRENT, PROTECTIVE COORDINATION AND
(AIC) RATINGS. ACTUAL IMPEDANCE VALUES FOR UTILITY AND CONTRACTOR PROPOSED
WERE USED FOR DESIGN CALCULATIONS TO DETERMINE AMPERE INTERRUPTING CURRENT
THE IMPEDANCE VALUE (%Z) IS PROVIDED FOR INFORMATION ONLY. THE INDICATED VALUES6.
SUBSTATION.
OR OTHER PROTECTIVE MATERIAL AND SHALL BE LOCATED BY THE ENTRANCE OF THE
INSTALLED EQUIPMENT. THE ONE-LINE DIAGRAM SHALL BE MOUNTED IN RIGID PLEXIGLASS
SHOW ALL INFORMATION INCLUDED ON THIS DRAWING, CORRECTED TO MATCH ACTUAL
DIAGRAM SHALL BE UPDATED AS OF THE BENEFICIAL OCCUPANCY DATE, AND SHALL
DISTRIBUTION SHALL BE WALL MOUNTED WITHIN THE NEW SUBSTATION. THE ONE-LINE
A COMPUTER GENERATED 11"X17" POWER ONE-LINE DIAGRAM SHOWING THE NEW 5.
ELECTRICAL WORK DESCRIPTION.
SUBSTATION B.7102 TO NEW PACKAGED SUBSTATION B.7101. SEE ES-102 FOR EXTERIOR
PROVIDE NEW AWG #4/0 TYPE MV-105 5KV SHIELDED POWER CABLES FROM EXISTING
RELOCATE PORTION OF EXISTING K16 FEEDERS FROM K-PLANT TO NEW SUBSTATION (B.7101).4.
SEE ES-101 THRU ES-102 FOR ELECTRICAL SITE DRAWINGS AND NOTES.3.
SEE SHEET EP-601, EP-602 FOR FEEDER SCHEDULES.2.
SEE E-001 FOR ELECTRICAL LEGENDS AND SYMBOLS.1.
NOTE:
R
E V
IS
E D N
O T
O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R of Engineers
US Army Corps
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
C O
N T
R A
C T N
O
SHEET OF XXX
IP
S
H O
R T
D E
S
IG
N
A N
S I
D
U S
E R
N A
M E
P L
O T
T E
D B
Y
S
Y T
IM
E
M E
U S
E R
N A
M E
S u b m i t t e d b y
D D
M M
M
Y Y
:M
M P l t e
New York District
NUMBER
REFERENCE
SHEET
N E
W Y
O R
K D
IS
T R
IC
T
N Y
C O
R P
S O
F E
N G
IN
E E
R S
U S
A R
M Y E
N G
IN
E E
R D
IS
T R
IC
T F
Y D
O R
M
IT
O R
Y T
H U
L E A
F B
G R
E E
N L
A N
D N
O V
F
D W
DNDN
UP
F
D W
F
F
DW
D D
D
DN
F
D W
W W
F DW
D
W
F
D W
SB
SB
P P
P P
P
P 3
D D D
D
D
D D
D
T
T
J
J
2 3 4 5 6 10
A
D
C
B
7 81
C.1
P5
E.2
E
6.2
6.4
P4P3
A.1
PA
PB
P1 P2
9.1 P6
TYPE A
(TYP)
P1A
P1B
P1C
P1D
P1E
P1F
P1G
TYPE BL
(TYP)
TYPE WL (TYP)
ON CKT H-1,12,
VIA LIGHTING
CONTACTOR
MDP-DISTR
MDP-MAIN
H-1
P-1
FACP
TYPE B14
(TYP)
TYPE A
(TYP)
TYPE B14
(TYP)
TYPE B14
(TYP)
TYPE S3
(TYP)
TYPE S3
(TYP)
TYPE WL
(TYP) VIA
LIGHTING
CONTACTOR
TYPE L2
(TYP)
TYPE LL2
(TYP)
TYPE W4
(TYP)
TYPE LL1
(TYP)
TYPE BL
(TYP)
E E
E
E E
E
E
E
E
E
E
E E
E
E
HT1
EL-402
HT2M-1
E
TYPE LL1
(TYP)
TYPE BL
(TYP)
TYPE A
(TYP)
TYPE LL2
(TYP)
7 8
TYP UL4
(TYP) 10
TYPE LL1
(TYP)
5 11 12 6
TYPE UL4
(TYP)16
TYPE LL2
(TYP)
TYPE LL2
(TYP)
H-1, D-1
TYPE LL2
(TYP)
H-1, 19"
RACK H-1,
H-1, H-1, TYP WL,
H-1, 12
H-1, H-1, H-1, TO WALL PAKS
ON UPPER
FLOORS WITH
SWITCH
TYP WL
SEE NOTE 11
ON EL-101
EL-402
H-1,5
H-1,5
H-1,5
H-1,5
H-1,5 H-1,5
H-1,5
H-1,5
H-1,5
SEE NOTE
7 (TYP)
SEE NOTE
7 (TYP)
EL-402
EL-402
EL-401
Sim
EL-401
Sim
EL-402
STAIRWELL A
STAIRWELL B
EL-402
TYPE A
(TYP)
TYPE A
(TYP)
TYPE A
(TYP)
TYPE A
(TYP)
NL NL NL NL NL NL
NL
NL
NL
NL NL
NL
SEE CIRCUITING IN DETAIL 1, EL-401
US Army Corps of Engineers New York District
SY
M
BO
L
R
EV
IS
IO
N D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
D
AT
E:
N O
V 5, SC
A L
E:
D R
A W
IN
G C
O D
E :
D
ES
IG
N
ED
B
Y:
D R
A W N
B Y :
C H
E C
KE
D B
Y:
IS
S U
E D
AT
E:
D
AT
E:
EN
G
IN
EE
R
AR
C H
IT
EC
T N
AM
E
PR
O
JE
C
T
EN
G
IN
EE
R
A R
C H
IT
EC
T
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
C O
R
PS
O F
EN
G
IN
EE
R S
N
EW
Y O
R K
D
IS
TR
IC
T, N
Y
SHEET
REFERENCE
NUMBER:
DATE:
FILE PATH: S:\Projects\Thule_AB\FY13_Dormitory\Con_Docs\BIM_Models\Electrical\ELEC_FY13_DORM.rvt
12/21/2012 4:02:09 PM
EL-101
AC AC TS
FY
D
O R
M
IT
O R
Y, T
H U
LE
A
FB
G R
EE
N
LA
N
D
LI
G
HT
IN
G
FI
RS
T
FL
O O
R
PL
AN
1 : 1001 LIGHTING FIRST FLOOR
NOTE:
1. ALL LIGHTING CIRCUITS ALONG CORRIDORS/STAIRWELLS SHALL BE CONTROLLED VIA CEILING MOUNTED OCCUPANCY SENSORS. SEE EL-
502 FOR LIGHTING CONTROLS AND PROGRAMMING REQUIREMENTS.
2. REFER TO LIGHTING FIXTURE SCHEDULE IN EL-501.
3. ALL CORRIDOR LIGHTING CIRCUITS SHALL BE A MINIMUM OF AWG #10 (5.5MM2) WIRE SIZES.
4. SEE TYPICAL DETAILS FOR MODULE A, B, AND D IN EL-401..
5. ALL NUMBERS NEXT TO DEVICES REPRESENTS THE CIRCUIT NUMBERS. THE PANEL SUPPLYING THE CIRCUITS ARE LOCATED WITHIN EACH PAIR OF MODULE A, OR MODULE B. FOR MODULE D, ALL DEVICES ARE SERVED BY A COMMON PANEL FOR THE UNIT.
6. FOR LIGHTING FIXTURES IN MECH AND ELEC ROOMS, CONTRACTOR SHALL ADJUST MOUNTING LOCATIONS AVOIDING CONFLICTS OF
NEARBY UTILITY PIPES.
7. LIGHTING FIXTURES IN ELECTRICAL & MECHANICAL ROOMS SHALL BE CLEARED FROM OTHER EQUIPMENT INSIDE THOSE ROOMS (I.E.
DUCTWORK, HYDRONIC PIPING, STEEL STRUCTURES, ETC.). WHERE REQUIRED, ORIENTATION MAYBE ALTERED TO ACHIEVE INSTALLATION
REQUIREMENT.
8. SEE ARCH CEILING AND FLOORPLANS FOR COORDINATED SPACINGS OF DEVICES (E.G. LIGHTING FIXTURES, SPEAKERS, ETC) AMONG ALL
TRADES.
9. CONTRACTOR SHALL PROVIDE AND INSTALL PHOTOCELL FOR FACADE LIGHTING (TYPE WL) AT FRONT OF BUILDING (OUTSIDE CANOPY).
ADJUST POSITION FOR OPTIMAL LIGHT EXPOSURE.
10. EXTERIOR FIXTURES (I.E.TYPE WL, ETC.) SHALL BE INSTALLED WITHOUT ANY EXPOSED CONDUITS ON FACADE OF BLDG.
11. EXTERIOR FIXTURES FOR CARGO DOORS SHALL BE INSTALLED CLEARED AWAY FROM LIFT OPERATION AND EQUIPMENT SETUP
LOCATIONS. REQUIRES COORDINATION WITH USER ON SETUP LOCATION.
12. PROVIDE ACCESS PANELS NO SMALLER THAN 300MM X 300MM FOR FIXTURES AND BOXES WHERE DIRECT ACCESS IS NOT PRACTICAL.
COORDINATE ACCESS PANEL LOCATIONS WITH OTHER TRADES.
R
EV
IS
ED
N
O
TE
S
/2 1/
AC
F
D W
DNDN
UP
F
D W
F
F
DW
D D
D
DN
F
D W
W W
F DW
D W
F
D W
SB
SB
A
AA
A A
G
A A
A
A
A
A A
A
A
G G
G
A A
A A
A
A A
A
A A
G
A
A
A
AA
G
A
A A A
A A
A
A A
G G
G
A
A
A A A
A
A
A
A A
G
G
G
G
G
G
G G
G
G
G
G G
G
AA A
G
D
D D
D
G G
G
G
G
J
J
J
J J
J
J
J
J J
J
J
2 3 4 5 6 10
A
D
C
B
7 81
B.1
C.1
P5
E.2
E
6.2
6.4
P4P3
A.1
PA
PB
9.1 P6
P1A P1C
P1D
P1E
P1F
P1G
P1B
MDP-DISTR
MDP-MAIN
H-1
P-1
FACP
19"
TELCOM
RACK
EP-404
DISHWASHER
REFRIG
+1880
MICROWAVE
WASHERS
RECP,
NEMA 6-20R
SEE NOTE 1 (TYP)
RANGE,
208V
REFRIG
+1880
DISH-
WASHER
RANGE,
208V
D-1
M-1 HT1
DRYERS
RECP,
208V, 30A
NEMA 6-30R
HT2
TREADMILL
RECP (TYP)
1 2
65 12
19,21
HOOD
9 10
HOOD
15 23
MICROWAVE
1719,21
H-1, CKT 1
H-1, H-1, H-1, H-1, CKT 3
H-1, H-1, H-1, CKT 3
H-1, H-1, H-1, H-1, UH-4, 16W,
CKT. H-1,18
UH-4,
16W, H-1,18
UH-2,
25W
UH-2,
25W
UH-2,
25W
CUH-1,
16W
H-1, 18
CUH-1,
16W, CKT.
H-1,18
UH-2,
25W, CKT. H-1,18
CUH-1,
16W
UH-2,
25W
H-1,18
D-1, 1,3
2,4
5,7
6,8
9,11
5HP/S
2HP/R
M-1, 1,3,5
STAIRWELL A
STAIRWELL B
EP-401
Sim
EP-401
Sim
HX-PKG-3
P-5
P-6
0.3KW
0.3KW M-1,
2,4,6 AHU-1
NOTE 1A, EP-101
EP-404
EP-404
SEE EP-404 FOR
J-BOX SIZE
NOTE 11 (TYP)
SF-1
0.25W
M-1, US Army Corps of Engineers New York District
SY
M
BO
L
R
EV
IS
IO
N D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
D
AT
E:
N O
V 5, SC
A L
E:
D R
A W
IN
G C
O D
E :
D
ES
IG
N
ED
B
Y:
D R
A W N
B Y :
C H
E C
KE
D B
Y:
IS
S U
E D
AT
E:
D
AT
E:
EN
G
IN
EE
R
AR
C H
IT
EC
T N
AM
E
PR
O
JE
C
T
EN
G
IN
EE
R
A R
C H
IT
EC
T
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
C O
R
PS
O F
EN
G
IN
EE
R S
N
EW
Y O
R K
D
IS
TR
IC
T, N
Y
SHEET
REFERENCE
NUMBER:
DATE:
FILE PATH: S:\Projects\Thule_AB\FY13_Dormitory\Con_Docs\BIM_Models\Electrical\ELEC_FY13_DORM.rvt
12/21/2012 4:02:32 PM
EP-101
AC AC TS
FY
D
O R
M
IT
O R
Y, T
H U
LE
A
FB
G R
EE
N
LA
N
D
PO
W
ER
P
LA
N
- F
IR
ST
FL
O O
R
1 : 1001 POWER PLAN - FIRST FLOOR
NOTE:
1. RECEPTACLES IN CORRIDORS SHOULD BE SPACED 10M OR LESS. IN ADDITION, ALL CORRIDOR RECP SHALL BE MOUNTED 1M AFF FOR
MAINTENANCE PURPOSES.
1A. ALL RECP IN JANITOR CLOSETS/HOUSEKEEPING/LAUNDRY ROOMS SHALL BE MOUNTED 1M AFF FOR MAINTENANCE PURPOSES.
2. REFER TO E-001 FOR LEGEND AND NOTES.
3. SEE TYPICAL DETAILS FOR MODULES D AND E IN EP-401.
4. ALL MECHANICAL EQUIPMENT SHALL BE EQUIPED WITH A DISCONNECT MEAN. SEE FEEDER SCHEDULE FOR SIZES.
5. ALL NUMBERS NEXT TO DEVICES REPRESENTS THE CIRCUIT NUMBERS. ALL DEVICES ARE SERVED BY A COMMON PANEL FOR THE MODULE UNITS D AND E. TENTATIVE LOCATIONS FOR PANELS SHOWN, HOWEVER CONTRACTOR SHALL FURTHER COORDINATE FOR OPTIMAL LOCATION
BASED UPON CLEARNACE FOR DOORWAY AND OTHER UTILITIES/PLUMBING LINES, ETC..
6. CONTRACTOR SHOULD INSTALL DRIP-PROOF DEVICES FOR ALL ELECTRICAL DEVICES IN MECHANICAL/UTILITY ROOMS WHERE FOREIGN
PIPES
WILL TRAVERSE INTO DEDICATED ELECTRICAL SPACE PER NFPA 70. ART.110.
7. COORDINATE INSTALLATION LOCATION OF ELECTRICAL DEVICES WITH OTHER DISCIPLINES (I.E. MECHANICAL, FIRE PROTECTION, PLUMBING, ETC.) WHENEVER NECESSARY. WHERE CONFLICTS OCCUR, CONTRACTOR SHALL RELOCATE ELECTRICAL DEVICES TO ANOTHER SUITABLE
LOCATIONS WHICH WILL COMPLY WITH NFPA 70.
8. RECEPTACLE FACEPLATE SHALL MATCH WITH ARCHITECTURAL FINISH. REFER TO FINISHING NOTES IN E-002.
9. SEE ARCH CEILING AND FLOORPLANS FOR COORDINATED SPACINGS OF DEVICES (E.G. LIGHTING FIXTURES, SPEAKERS, ETC) AMONG ALL
TRADES.
10. MECH LOAD: NOT ALL SMALL MECH LOADS (I.E. SUPPLY FANS, EXHAUST FANS, ETC.) MAY HAVE BEEN ACCOUNTED FOR. COORDINATE WITH MECH TRADES FOR EXACT LOAD SIZES, AND PROVIDE APPROPRIATE CIRCUIT SIZING AS REQUIRED.
11. ALL RECESSED WALL-MOUNTED PANELBOARDS SHALL BE COORDINATED FOR OPTIMAL LOCATIONS WHERE WALL SPACE AND CLEARANCES ARE ACCESSIBLE. OPTIMAL LOCATIONS SHALL BE FREE OF CONFLICTS WITH OTHER PIPING (GAS, PLUMBING, WATER LINES, ETC.)
12. PROVIDE ACCESS PANELS NO SMALLER THAN 300MM X 300MM FOR FIXTURES AND BOXES WHERE DIRECT ACCESS IS NOT PRACTICAL.
COORDINATE ACCESS PANEL LOCATIONS WITH OTHER TRADES.
R
EV
IS
ED
N
O
TE
S
/2 1/
EP-601
TYPE TVSS SCHEUDLE
E L E
C T
R
IC
A L R
IS
E R D
IA
G R
A M
S
P1A P1B P1D P1E P1F P1G
P-1
1ST FLR
ELEC RM
H-1
225AF
225AT
P-2
2ND FLR
ELEC RM
H-2
P-3
3RD FLR
ELEC RM
H-3
150AF
125AT
D-1
D-2
D-3
M-1
225AF
225AT
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
MECH RM FIRST FLOOR
MECH RM SECOND FLOOR
MECH RM THIRD FLOOR
MOD D MOD D
M-2
M-3
HT-1
M
1600:5
SECTION
MAIN BREAKER
STACKED
ES-601.
CUBICLE. SEE
FROM TRANSFORMER
BOTTOM FED
3RD FLR
LAUNDRY
2ND FLR
LAUNDRY
1ST FLR
LAUNDRY
G
FEEDER SCHEDULE
100AF
30AT
SPARE
PROVIDE FULLY RATED NEUTRAL BUS.
SYMMETRICAL INTERRUPTING CAPACITY (A.I.C.) MINIMUM.
STATE TRIP TYPE, 3 POLE, AND HAVE 42,000 AMPS
ALL CIRCUIT BREAKERS SHALL BE OF THE SOLID
1600A MCB, 208-120Y, 3PHASE 4WIRE, 2000A BUS, 42KAIC
MDP - ELECTRICAL ROOM (1ST FLR)
ENTRY INTO BUILDING
SHEATH ARMORED POWER CABLE. PROVIDE BOOTS AND CABLE SUPPORT AT CABLE
6 SETS OF AWG 750KCM WITH #4/0 GND - 600V TYPE MC-HL, XHHW-2 ALUMINUM
INCLUDE DIGITAL SURGE COUNTER AND AUDIBLE ALARM
SERVICE ENTRANCE CLASS. 400KA/PHASE, L-N, L-G & N-G SUPPRESSION,
INCLUDE DIGITAL SURGE COUNTER AND AUDIBLE ALARM
SUBPANEL CLASS. 100KA/PHASE, L-N, L-G & N-G SUPPRESSION,
TVSS1
TVSS3
TVSS1
G
TVSS3
G
TYPICAL FOR ALL PANELS
SEE NOTE 9
#2/0 G TO NEAREST POWER GROUND BAR (PMGB)
P1C
MOD E
P2A P2B P2D P2E P2F P2G
MOD D MOD D
P2C
MOD E
P3A P3B P3D P3E P3F P3G
MOD D MOD D
P3C
MOD E
SIZED PER MFR
1600AF
1600AT
4-350KCM + 1-#2/0 GND IN 3"C EMT U.O.N.
4-500KCM + 1-#2/0 GND IN 3"C EMT U.O.N.
4 #2 + #2 GND IN 1-1/2"C EMT U.O.N.
400AF
350AT
400AF
350AT
400AF
350AT
400AF
350AT
HT-2
MLO
400AF
300AT
400AF
350AT
400AF
350AT
400AF
350AT
400AF
350AT
100AF
80AT
100AF
80AT
150AF
100AT
150AF
100AT
100AF
100AT
100AF
80AT
150AF
125AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
45 5
5555555
5555555
5555555
PER NEC ART.430.176.
7. FOR VFD TYPE MOTORS, PROVIDE OVER TEMPERATURE PROTECTION
BE RATED BASED UPON THE SERVICE FACTOR OF THE MOTOR UNIT.
ENCLOSURE, OR THE CONTROLLER. OVERLOAD PROTECTION SHALL
THE OVERLOAD DEVICE SHALL BE INTEGRAL TO THE MOTOR UNIT,
MOTOR NAMEPLATE FLA, WHENEVER APPROPRIATE. PREFERRABLY,
OVERLOAD PROTECTION SHALL BE DESIGNED/SELECTED BASED UPON
6. PROVIDE OVERLOAD PROTECTION FOR ALL MOTOR CIRCUITS.
AND INSTALLATION REQUIREMENTS.
GROUND FAULT PROTECTION. FOLLOW MANUFACTURER SPECIFICATION
CIRCUIT BREAKERS FOR HVAC EQUIPMENT FOR SHORT CIRCUIT AND
5. WHEN REQUIRED BY MANUFACTURER, PROVIDE LISTED HACR-TYPE
EQUIPMENT SELECTED
FAULT DEVICES, ETC.) SHALL BE SIZED BASED UPON ACTUAL
4. ALL MOTOR CIRCUITS (I.E. FEEDERS, OVERCURRENT AND GROUND
STARTING IN-RUSH CURRENTS.
SOFT STARTING TYPES, IN ORDER TO REDUCT EXCESSIVE MOTOR
FREQUENCY DRIVES, SHALL BE OF REDUCED VOLTAGE STARTING OR
3. ALL MOTOR STARTERS, ASIDE FROM THOSE THAT USE VARIABLE
ACCORDINGLY BASED UPON ACTUAL EQUIPMENT SELECTION.
THE BRANCH CIRCUITS AND BREAKER SIZES SHALL BE REVISED
OVERCURRENT PROTECTION). IF EQUIPMENT SELECTED SHOWS DEVIATION,
MANUFACTURER TO FINALIZE CIRCUIT SIZES (FEEDER SIZES AND
CONTRACTOR SHALL OBTAIN EQUIPMENT LOAD INFORMATION FROM
EQUIPMENT LOAD INFORMATION (ESPECIALLY FOR MECHANICAL LOAD).
1. CIRCUIT SIZES IN PANEL SCHEDULES ARE BASED ON ASSUMED
MOTOR CIRCUIT NOTES
4 4 4
NOT USED
SHOWN IN THESE DRAWINGS (I.E. ES-502, ES-601, EP-601, ETC.)
DIMENSION ARE SUITABLE AND CONSISTENT WITH THE DESIGN INTENT
MANUFACTURER, HE SHALL VERIFY ALL DESIGN SETTINGS, RATINGS AND
APPROVED EQUAL. SHOULD CONTRACTOR SELECT A DIFFERENT
11. ALL ELECTRICAL EQUIPMENT SHALL BE OF SQUARE D PRODUCTS OR
(I.E. CIRCUIT BREAKER, CONDUITS, ETC.) SHALL BE UPSIZED ACCORDINGLY.
CASES, CONTRACTOR SHALL ASSURE THAT ALL ASSOCIATED EQUIPMENT
STANDARD SIZE AND THE NEXT LARGER SIZE MAY BE USED. IN SUCH
10. CIRCUIT CONDUCTOR SIZES CALCULATED MAY NOT CORRESPOND TO A
RS-485, AND ETHERNET CONNECTION.
UMCS CONNECTION WITH BUILDING ENERGY CONTROL SYSTEM, RS-232,
VOLTS AND AMPS PER PHASE, AND KW DEMAND. PROVIDE INTERFACE FOR
THULE BCE. EQUIPMENT MUST BE CAPABLE TO READ KWH, POWER FACTOR,
USED AT THULE AIR BASE. COORDINATE METERING REQUIREMENT WITH
EQUAL, AND SHALL BE COMPATIBLE WITH THE COMMUNICATION PROTOCOL
9. ELECTRONIC METER SHALL BE E-MON CLASS 5000 MODEL OR APPROVED
TVSS SCHEDULE FOR TVSS CLASS TYPES.
ELECTRODE, COUNTERPOISE, OR BUILDING STEEL AS APPLICABLE. SEE
REQUIREMENT. TVSS SHALL BE GROUNDED TO THE NEAREST GROUND
MFR REQUIREMENTS. PROVIDE FUSE/OVERCURRENT PROTECTION PER MFR
AS SHORT DISTANCE AS POSSIBLE TO THE PANEL IT PROTECTS, IAW
8. PROVIDE TVSS ELEMENTS IN ALL PANELS. TVSS MUST BE INSTALLED
7. NOT USED.
SCHEDULE EP-602.
PANEL SCHEDULES IN EP-611 THRU EP-615. SEE ALSO FEEDER
6. SHORT CIRCUIT INTERRUPTING CAPACITY ARE REFERENCED IN THE
SEC 26 28 01.00 10 FOR REQUIREMENTS..
BREAKERS IN THE MAIN DISTRIBUTION PANEL (MDP). REFER TO SPEC
5. PROVIDE DIGITAL (SOLID STATE) ADJUSTABLE TRIP ELEMENTS FOR ALL
4. REFER TO MECH DWG ON ALL VFD PUMP CONTROLS REQUIREMENT.
CONTRACTING OFFICER’S REPRESENTATIVE.
MATERIAL AND SHALL BE LOCATED IN COORDINATION WITH THE
BE MOUNTED IN RIGID PLEXIGLASS OR OTHER APPROVED PROTECTIVE
MATCH ACTUAL INSTALLED EQUIPMENT. THE ONE-LINE DIAGRAM SHALL
SHOW ALL INFORMATION INCLUDED ON THIS DRAWING, CORRECTED TO
BE CURRENT AS OF THE BENEFICIAL OCCUPANCY DATE AND SHALL
WALL-MOUNTED IN ELECTRICAL ROOM 107. THE ONE-LINE DIAGRAM SHALL
3. A COMPUTER GENERATED 11"x17" POWER ONE-LINE DIAGRAM SHALL BE
BRANCH CIRCUITS SIZES. SEE EP-611 TO EP-615 FOR PANEL SCHEDULES.
2. SEE DWG EP-602 AND EP603 FOR FEEDER SCHEDULES AND EQUIPMENT
NOTES AND OTHER REQUIREMENTS.
1. SEE DWG E-001 AND E-002 FOR ELECTRICAL LEGENDS, ABBREVIATIONS,
NOTES
R
E V
IS
E D N
O T
E S
D
E C
A C
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R of Engineers
US Army Corps
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
C O
N T
R A
C T N
O
SHEET OF XXX
IP
S
H O
R T
D E
S
IG
N
A N
S I
D
U S
E R
N A
M E
P L
O T
T E
D B
Y
S
Y T
IM
E
M E
U S
E R
N A
M E
S u b m i t t e d b y
D D
M M
M
Y Y
:M
M P l t e
New York District
NUMBER
REFERENCE
SHEET
N E
W Y
O R
K D
IS
T R
IC
T
N Y
C O
R P
S O
F E
N G
IN
E E
R S
U S
A R
M Y E
N G
IN
E E
R D
IS
T R
IC
T F
Y D
O R
M
IT
O R
Y T
H U
L E A
F B
G R
E E
N L
A N
D N
O V
F
D W
DNDN
UP
F
D W
F
F
DW
D D
D
DN
F
D W
W W
F DW
D
W
F
D W
SB
SB
W
CR KP
CR KP
CR KP
C R
K P
W
CR CR
CR CR
CR
CR
C R
CR CR
C R
CR
CR CR
CR KP
CR KP CR
CR
CR CR
CR CR
C R
C R
C R
S S S
S S
S S S S
S
S
S
S
S S
W
W
CR
CR KP
S s s
S
S
PROVIDE
WITH WP
ENCLOSURE
PROVIDE
WITH WP
ENCLOSURE
PROVIDE WALL MTD SPEAKER
FOR MECH & ELEC ROOMS, TO
BE MTD 8'-0" AFF.
19" FRONT-
ACCESS RACK
(TYP)
D C.1
C
B
A
10987654321
B.1
P5 P6
P1 P2
6.1
E.1
E.2
A.1
P7 P8
PROVIDE
WITH WP
ENCLOSURE
PROVIDE W/
SPILLPROOF
ENCLOSURE
P1A
P1B
P1C
P1D
H-1
P-1
FACP
P1E
P1F
P1G
M-1 HT1 HT2
D-1
WALL MOUNTED
SPEAKERS (TYP)
SEE ET-604 FOR
SPEC.
SEE
NOTE 6
CARD READERS
WITH KEYPAD
(TYP)
CEILNG MTD
SPEAKER.
SEE ET-604
FOR SPEC.
4"Wx2"D WIRE MESH TRAY ALONG
CORRIDOR. SEE NOTE 8 (TYP)
CARD READERS
WITH KEYPAD
(TYP)
MDP-DISTR
MDP-MAIN
6"Wx4"D WIRE
MESH CABLE
TRAY. SEE
NOTE 8
4"Wx2"D WIRE MESH TRAY ALONG
CORRIDOR. SEE NOTE 8 (TYP)
EP-404
US Army Corps of Engineers New York District
SY
M
BO
L
R
EV
IS
IO
N D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
D
AT
E:
N O
V 5, SC
A L
E:
D R
A W
IN
G C
O D
E :
D
ES
IG
N
ED
B
Y:
D R
A W N
B Y :
C H
E C
KE
D B
Y:
IS
S U
E D
AT
E:
D
AT
E:
EN
G
IN
EE
R
AR
C H
IT
EC
T N
AM
E
PR
O
JE
C
T
EN
G
IN
EE
R
A R
C H
IT
EC
T
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
C O
R
PS
O F
EN
G
IN
EE
R S
N
EW
Y O
R K
D
IS
TR
IC
T, N
Y
SHEET
REFERENCE
NUMBER:
DATE:
FILE PATH: S:\Projects\Thule_AB\FY13_Dormitory\Con_Docs\BIM_Models\Electrical\ELEC_FY13_DORM.rvt
12/21/2012 4:02:47 PM
ET-101
AC AC TS
FY
D
O R
M
IT
O R
Y, T
H U
LE
A
FB
G R
EE
N
LA
N
D
TE
LE
CO
M
S
EC
UR
IT
Y
PL
AN
FI
RS
T
FL
O
O R
1 : 1001 COMM FIRST FLOOR
NOTES: (NOTES SHALL BE APPLICABLE TO ALL TELCOM DRAWINGS)
1. MAINTAIN A MINIMUM OF 2-FT (610MM) SEPARATION BETWEEN POWER AND TELCOM EQUIPMENT.
2. SEE DETAILS IN PLATE ET-505 FOR WALL PLATE CONFIGURATION OF TELECOM JACKS.
3. COORDINATE CEILING SPEAKERS LAYOUT WITH CEILING TILES AND LIGHTING FIXTURES. LOCATE SPEAKER JACKS ABOVE CEILING VOID FOR
CONNECTION.
4. PROVIDE ACCESSIBLE MEANS/PANELS TO ACCESS CABLE TRAYS ABOVE CEILING.
5. CARD ACCESS SHALL BE PROVIDED ON ALL MODULES. CARD ACCESS WITH KEY PAD SHALL BE PROVIDED IN MECH ROOMS, ELEC ROOM, LAUNDRY, JANITOR CLOSET AND COMMON TOLIETS. CARD ACCESS SYSTEM SHALL BE SIEMENS SIPASS OR APPROVED EQUAL. REFER TO DWG ET-
603 FOR DETAILS.
6. COORDINATE LOCATION OF DATA JACK WITH BUILDING AUTMATION PANEL LOCATION. COORDINATE WITH MECHANICAL/ELECTRICAL TRADES.
7. SEE ARCH CEILING AND FLOORPLANS FOR COORDINATED SPACINGS OF DEVICES (E.G. LIGHTING FIXTURES, SPEAKERS, MECH DEVICES, ETC)
AMONG ALL TRADES.
8. CABLE TRAY ABOVE CEILING SHALL BE WIRE MESH TYPE CABLE TRAY SIZE IN CORRDORS AND LOW USAGE AREAS SHALL BE 4"Wx2"D. CABLE TRAY COMING OUT FROM TELECOM RACK SHALL BE 6"Wx4"D. AT ALL TIMES, CONTRACTOR SHALL ASSURE CABLE FILL RATIO WILL NOT EXCEED 50%
OF THE CROSS SECTIONAL AREA OF CABLE TRAY.
9. IN TIGHT CORNERS, TURNS OR ACCESS SPACE ABOVE CEILING, PROVIDE MANUFACTURER SOLUTION OR RE-ROUTE CABLE TRAY AROUND TO ACCOMODATE CONNECTIONS IN LAYOUT, SUCH AS VIA THE USE OF SMALLER CABLE TRAY (WHERE CABLE FILL RATIO PERMITTED) AND JOINING OF
MULTIPLE BENDING SECTIONS PER MANUFACTURER REQUIREMENTS.
10. FROM CABLE TRAY TO INDIVIDUAL OUTLET LOCATIONS, WIRING SHALL BE ROUTED IN 1-1/4" CONDUITS EMT.
11. ALL TELECOM RACEWAYS SHALL BE INSTALLED CONCEALED IN PARTITIONS OR WALL STRUCTURES. WHERE EXPOSED INSTALLATION IS UNAVOIDABLE AND NECESSARY, NOTIFY THE CONTRACTOR OFFCIER REPRESENTATIVE (COR) FOR COORDINATION, REVIEW OF METHOD AND
APPROVAL.
12. PROVIDE ACCESS PANELS NO SMALLER THAN 300MM X 300MM FOR FIXTURES AND BOXES WHERE DIRECT ACCESS IS NOT PRACTICAL.
COORDINATE ACCESS PANEL LOCATIONS WITH OTHER TRADES.
R
EV
IS
ED
N
O
TE
S
/2 1/
| E-002 - ELEC NOTES-AMEND2 |
| ES-601 - SITE ELEC RISER DIAGRAM-AMEND2 |
| EL-101 - LIGHTING - FIRST FLOOR PLAN - AMEND2 |
| EP-101 - POWER PLAN - FIRST FLOOR - AMEND2 |
| EP-601 - RISER DIAGRAM-AMEND2 |
| ET-101 - TELECOM & SECURITY PLAN - FIRST FLOOR - AMEND2 |
File details come from the government source that posted it. Updated .