EP-601
TYPE TVSS SCHEUDLE
E L E
C T
R
IC
A L R
IS
E R D
IA
G R
A M
S
P1A P1B P1D P1E P1F P1G
P-1
1ST FLR
ELEC RM
H-1
225AF
225AT
P-2
2ND FLR
ELEC RM
H-2
P-3
3RD FLR
ELEC RM
H-3
150AF
125AT
D-1
D-2
D-3
M-1
225AF
225AT
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
MECH RM FIRST FLOOR
MECH RM SECOND FLOOR
MECH RM THIRD FLOOR
MOD D MOD D
M-2
M-3
HT-1
M
1600:5
SECTION
MAIN BREAKER
STACKED
ES-601.
CUBICLE. SEE
FROM TRANSFORMER
BOTTOM FED
3RD FLR
LAUNDRY
2ND FLR
LAUNDRY
1ST FLR
LAUNDRY
G
FEEDER SCHEDULE
100AF
30AT
SPARE
PROVIDE FULLY RATED NEUTRAL BUS.
SYMMETRICAL INTERRUPTING CAPACITY (A.I.C.) MINIMUM.
STATE TRIP TYPE, 3 POLE, AND HAVE 42,000 AMPS
ALL CIRCUIT BREAKERS SHALL BE OF THE SOLID
1600A MCB, 208-120Y, 3PHASE 4WIRE, 2000A BUS, 42KAIC
MDP - ELECTRICAL ROOM (1ST FLR)
ENTRY INTO BUILDING
SHEATH ARMORED POWER CABLE. PROVIDE BOOTS AND CABLE SUPPORT AT CABLE
6 SETS OF AWG 750KCM WITH #4/0 GND - 600V TYPE MC-HL, XHHW-2 ALUMINUM
INCLUDE DIGITAL SURGE COUNTER AND AUDIBLE ALARM
SERVICE ENTRANCE CLASS. 400KA/PHASE, L-N, L-G & N-G SUPPRESSION,
INCLUDE DIGITAL SURGE COUNTER AND AUDIBLE ALARM
SUBPANEL CLASS. 100KA/PHASE, L-N, L-G & N-G SUPPRESSION,
TVSS1
TVSS3
TVSS1
G
TVSS3
G
TYPICAL FOR ALL PANELS
SEE NOTE 9
#2/0 G TO NEAREST POWER GROUND BAR (PMGB)
P1C
MOD E
P2A P2B P2D P2E P2F P2G
MOD D MOD D
P2C
MOD E
P3A P3B P3D P3E P3F P3G
MOD D MOD D
P3C
MOD E
SIZED PER MFR
1600AF
1600AT
4-350KCM + 1-#2/0 GND IN 3"C EMT U.O.N.
4-500KCM + 1-#2/0 GND IN 3"C EMT U.O.N.
4 #2 + #2 GND IN 1-1/2"C EMT U.O.N.
400AF
350AT
400AF
350AT
400AF
350AT
400AF
350AT
HT-2
MLO
400AF
300AT
400AF
350AT
400AF
350AT
400AF
350AT
400AF
350AT
100AF
80AT
100AF
80AT
150AF
100AT
150AF
100AT
100AF
100AT
100AF
80AT
150AF
125AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
100AF
80AT
45 5
5555555
5555555
5555555
PER NEC ART.430.176.
7. FOR VFD TYPE MOTORS, PROVIDE OVER TEMPERATURE PROTECTION
BE RATED BASED UPON THE SERVICE FACTOR OF THE MOTOR UNIT.
ENCLOSURE, OR THE CONTROLLER. OVERLOAD PROTECTION SHALL
THE OVERLOAD DEVICE SHALL BE INTEGRAL TO THE MOTOR UNIT,
MOTOR NAMEPLATE FLA, WHENEVER APPROPRIATE. PREFERRABLY,
OVERLOAD PROTECTION SHALL BE DESIGNED/SELECTED BASED UPON
6. PROVIDE OVERLOAD PROTECTION FOR ALL MOTOR CIRCUITS.
AND INSTALLATION REQUIREMENTS.
GROUND FAULT PROTECTION. FOLLOW MANUFACTURER SPECIFICATION
CIRCUIT BREAKERS FOR HVAC EQUIPMENT FOR SHORT CIRCUIT AND
5. WHEN REQUIRED BY MANUFACTURER, PROVIDE LISTED HACR-TYPE
EQUIPMENT SELECTED
FAULT DEVICES, ETC.) SHALL BE SIZED BASED UPON ACTUAL
4. ALL MOTOR CIRCUITS (I.E. FEEDERS, OVERCURRENT AND GROUND
STARTING IN-RUSH CURRENTS.
SOFT STARTING TYPES, IN ORDER TO REDUCT EXCESSIVE MOTOR
FREQUENCY DRIVES, SHALL BE OF REDUCED VOLTAGE STARTING OR
3. ALL MOTOR STARTERS, ASIDE FROM THOSE THAT USE VARIABLE
ACCORDINGLY BASED UPON ACTUAL EQUIPMENT SELECTION.
THE BRANCH CIRCUITS AND BREAKER SIZES SHALL BE REVISED
OVERCURRENT PROTECTION). IF EQUIPMENT SELECTED SHOWS DEVIATION,
MANUFACTURER TO FINALIZE CIRCUIT SIZES (FEEDER SIZES AND
CONTRACTOR SHALL OBTAIN EQUIPMENT LOAD INFORMATION FROM
EQUIPMENT LOAD INFORMATION (ESPECIALLY FOR MECHANICAL LOAD).
1. CIRCUIT SIZES IN PANEL SCHEDULES ARE BASED ON ASSUMED
MOTOR CIRCUIT NOTES
SHOWN IN THESE DRAWINGS (I.E. ES-502, ES-601, EP-601, ETC.)
DIMENSION ARE SUITABLE AND CONSISTENT WITH THE DESIGN INTENT
MANUFACTURER, HE SHALL VERIFY ALL DESIGN SETTINGS, RATINGS AND
APPROVED EQUAL. SHOULD CONTRACTOR SELECT A DIFFERENT
11. ALL ELECTRICAL EQUIPMENT SHALL BE OF SQUARE D PRODUCTS OR
(I.E. CIRCUIT BREAKER, CONDUITS, ETC.) SHALL BE UPSIZED ACCORDINGLY.
CASES, CONTRACTOR SHALL ASSURE THAT ALL ASSOCIATED EQUIPMENT
STANDARD SIZE AND THE NEXT LARGER SIZE MAY BE USED. IN SUCH
10. CIRCUIT CONDUCTOR SIZES CALCULATED MAY NOT CORRESPOND TO A
AND ETHERNET CONNECTION.
CONNECTION WITH BUILDING ENERGY CONTROL SYSTEM, RS-232, RS-485,
AND AMPS PER PHASE, AND KW DEMAND. PROVIDE INTERFACE FOR UMCS
EQUIPMENT MUST BE CAPABLE TO READ KWH, POWER FACTOR, VOLTS
AIR BASE. COORDINATE METERING REQUIREMENT WITH THULE BCE.
BE COMPATIBLE WITH THE COMMUNICATION PROTOCOL USED AT THULE
9. ELECTRONIC METER SHALL BE ION7650 OR APPROVED EQUAL, AND SHALL
TVSS SCHEDULE FOR TVSS CLASS TYPES.
ELECTRODE, COUNTERPOISE, OR BUILDING STEEL AS APPLICABLE. SEE
REQUIREMENT. TVSS SHALL BE GROUNDED TO THE NEAREST GROUND
MFR REQUIREMENTS. PROVIDE FUSE/OVERCURRENT PROTECTION PER MFR
AS SHORT DISTANCE AS POSSIBLE TO THE PANEL IT PROTECTS, IAW
8. PROVIDE TVSS ELEMENTS IN ALL PANELS. TVSS MUST BE INSTALLED
7. NOT USED.
SCHEDULE EP-602.
PANEL SCHEDULES IN EP-611 THRU EP-615. SEE ALSO FEEDER
6. SHORT CIRCUIT INTERRUPTING CAPACITY ARE REFERENCED IN THE
SEC 26 28 01.00 10 FOR REQUIREMENTS..
BREAKERS IN THE MAIN DISTRIBUTION PANEL (MDP). REFER TO SPEC
5. PROVIDE DIGITAL (SOLID STATE) ADJUSTABLE TRIP ELEMENTS FOR ALL
4. REFER TO MECH DWG ON ALL VFD PUMP CONTROLS REQUIREMENT.
CONTRACTING OFFICER’S REPRESENTATIVE.
MATERIAL AND SHALL BE LOCATED IN COORDINATION WITH THE
BE MOUNTED IN RIGID PLEXIGLASS OR OTHER APPROVED PROTECTIVE
MATCH ACTUAL INSTALLED EQUIPMENT. THE ONE-LINE DIAGRAM SHALL
SHOW ALL INFORMATION INCLUDED ON THIS DRAWING, CORRECTED TO
BE CURRENT AS OF THE BENEFICIAL OCCUPANCY DATE AND SHALL
WALL-MOUNTED IN ELECTRICAL ROOM 107. THE ONE-LINE DIAGRAM SHALL
3. A COMPUTER GENERATED 11"x17" POWER ONE-LINE DIAGRAM SHALL BE
BRANCH CIRCUITS SIZES. SEE EP-611 TO EP-615 FOR PANEL SCHEDULES.
2. SEE DWG EP-602 AND EP603 FOR FEEDER SCHEDULES AND EQUIPMENT
NOTES AND OTHER REQUIREMENTS.
1. SEE DWG E-001 AND E-002 FOR ELECTRICAL LEGENDS, ABBREVIATIONS,
NOTES
4 4 4
4 #1 + #1 GND IN 2"C EMT U.O.N.
R
E V
IS
IO
N O
N F
E E
D E
R S
C H
E D
U L E
/0
/2
A C
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R of Engineers
US Army Corps
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
C O
N T
R A
C T N
O
SHEET OF XXX
IP
S
H O
R T
D E
S
IG
N
A N
S I
D
U S
E R
N A
M E
P L
O T
T E
D B
Y
S
Y T
IM
E
F I L
E
N A
M E
U S
E R
N A
M E
S u b m i t t e d b y
D D
M M
M
Y Y
Y
H
:M
M P l o t
D a t e
New York District
NUMBER
REFERENCE
SHEET
N E
W Y
O R
K D
IS
T R
IC
T
N Y
C O
R P
S O
F E
N G
IN
E E
R S
U S
A R
M Y E
N G
IN
E E
R D
IS
T R
IC
T F
Y D
O R
M
IT
O R
Y T
H U
L E A
F B
G R
E E
N L
A
EP-602
E
E D
E R S
C H
E D
U L E C
A L
C U
L A
T
IO
N
1. CABLE LENGTH SHOWN IN SCHEDULE IS APPROXIMATE. CONTRACTOR SHALL VERIFY IN THE FIELD.
NOTES:
/0
/2
A C
R E
V
IS
IO
N O
N F
E E
D E
R S
IZ
E S
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R of Engineers
US Army Corps
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
C O
N T
R A
C T N
O
SHEET OF XXX
IP
S
H O
R T
D E
S
IG
N
A N
S I
D
U S
E R
N A
M E
P L
O T
T E
D B
Y
S
Y T
IM
E
I L
E
A
M E
U S
E R
N A
M E
S u b m i t t e d b y
D D
M M
M
Y Y
:M
M P l o t a t e
New York District
NUMBER
REFERENCE
SHEET
N E
W Y
O R
K D
IS
T R
IC
T
N Y
C O
R P
S O
F E
N G
IN
E E
R S
U S
A R
M Y E
N G
IN
E E
R D
IS
T R
IC
T F
Y D
O R
M
IT
O R
Y T
H U
L E A
F B
G R
E E
N L
A