TSF Building Dimensioned Drawings and Reflected Ceilings.pdf

PDF 4 MB Posted

Attached to
Intrusion Detection System (IDS) Conduit Installation Federal contract opportunity
Solicitation number
W912CH-24-R-L002
Issued by
Department of the Army

About this file

This document is a set of design drawings and a reflected ceiling plan for the Training Support Facility (TSF) at the United States Army Aviation Museum at Fort Rucker, Alabama. The drawings depict the floor plans, ceiling layouts, and various building details for Zones A, B, and C of the facility. Key features include the placement of rooms, equipment, furnishings, windows, doors, and other architectural elements. The drawings also show the layout of the mechanical, electrical, and structural systems. This is not a solicitation document, but rather detailed design plans for the construction and build-out of the TSF.

View the file

Other files for this federal contract opportunity

Other files attached to Intrusion Detection System (IDS) Conduit Installation, newest first.
File Type Posted
IDS Conduit SOL_Amendment 0003.pdf PDF
IDS Conduit SOL QA log_14 May.pdf PDF
IDS Conduit SOL_Amendment 0002.pdf PDF
IDS Conduit SOL_Amendment 0001.pdf PDF
IDS Conduit SOL QA log_30 April.docx DOCX document
Technical Exhibit 15 - Delivery Schedule.docx DOCX document
Final_SOW TSF IDS Conduit_revised 24 April.docx DOCX document
Technical Exhibit 14_Architectural Square Footage.pdf PDF
Attachment 1_Photos and Images.pdf PDF
Security 2000 Drawings.pdf PDF
FINAL_SOL_IDS Conduit.pdf PDF
Final_CDRL A001 TSF IDS Conduit Install.pdf PDF
Final_CDRL A002 TSF IDS Conduit Install.pdf PDF
Technical Exhibit 14 - Delivery Schedule.docx DOCX document
Governement Drawings.pdf PDF
Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

B

C

1 2 3

A-301.1

A-302.1

A-413.1

MECHANICAL

ELECTRICAL

COMM

JANITOR

MECHANICAL

ARMS

ELEV.

LOBBY

ELEV

EQUIP

BIKE

STORAGE

106MEN

WOMEN

A-401.1

STAIR

S2

STAIR

S1

CORRIDOR

CORRIDOR

A-410.1

S1A

S1B

116A

S2A

S2B

3C

35' - 2" 2' - 0" 6' - 0" EQ. 120'-0" (WALL TYPE W2) EQ. 6' - 0" 2' - 0" 35' - 2"

A.5

3.51.5 2 A-302.1

3' - 4"

3' - 4"

6'

8"

/8

/8

29' - 0"

10' - 0 1/2" 30' - 3 7/8" 100' - 3 1/2" 10' - 8 1/8"

A-411.1

10' - 5 1/8" 8' - 2" CLR 10' - 6 1/8"

6' - 2" 39' - 0" 30' - 0" 35' - 0" 35' - 0" 30' - 0"

2.5

KN1

KN3

FEB

FEC FEC

2 4

10 10

FEC

CW3

CW3

KN5

KN 9

2" RECESSED SLAB (SHOWN HATCHED)

7'

6"

6'

3"

LINE OF MEZZANINE

ABOVE

MATCHLINEMATCHLINE

A-510.1

A-510.1

A-510.1

A-510.1

OPP.

HAND

5A

9A

116B 9' - 7 3/4" 10' - 0" 9' - 4 1/2"

3'

/2

8' - 8"

6'

3/

4"

10' - 1 3/8"

KN9

FEB

FE

B

A-504.1

MECHANICAL LOUVER,

SEE 10/A-611.1

MECHANICAL LOUVER,

SEE 10/A-611.1

12' - 0" 12' - 0" 13' - 11"

W2

W1 W1

W1 W2 W1

2' - 2 1/2"

CG2

CG2

CG2 EC2 EC2

DISPLAY

CG2

DSDS DS DS

DS

DS

DS

DS

KEY NOTES LEGEND

FEC SEMI-RECESSED FIRE EXTINGUISHER CABINET.

REFER TO DETAIL 3/A-535.1.

FEB WALL MOUNTED FIRE EXTINGUISHER BRACKET.

MOUNT AT 48" AFF.

DS DOWNSPOUT

BEJ BRICK EXPANSION JOINT - REFER TO 3/A-522.1

CJ CONTROL JOINT - SEE STRUCT FOR DETAIL

CG1 VINYL CORNER GUARD - SEE 2/A-511.1

CG2 ALUMINUM CORNER GUARD - SEE 10/A-511.1

EC1 VINYL END CAP - SEE 8/A-511.1

EC2 ALUMINUM END CAP - SEE 9/A-511.1

KN1 MOP SINK - SEE PLUMBING

KN2 ENTRANCE FLOOR MAT (EM-1) CENTERED ON

DOOR FRAME.

KN3 ELECTRIC WATER COOLER

KN4 PROVIDE KNOX BOX - REFER TO DETAIL 1/A-502.1

KN5 PROVIDE 5/8" STAINLESS STEEL EYELETS

W/ 2" DIA. EYE AT 5'-0" A.F.F. SPACING SHALL BE

COORDINATED WITH CONTRACTING OFFICER.

KN6 42" HIGH GUARDRAIL - REFER TO DETAILS ON A-416.1.

KN7 SCREEN WALL WITH METAL PERFORATED IMAGE

PANELS. SEE PLATE A-505.1 FOR DETAILS.

CONSTRUCTION SYSTEMS AND WALL TYPES - REFER TO

PLATES A-001.1 THRU A-002.1.

ROOM NUMBER

WINDOW OR LOUVER TYPE - REFER TO WINDOW AND

LOUVER TYPES AND DETAILS ON PLATES A-602.1

1-HOUR RATED PARTITION

X

KN8 42" REMOVABLE HIGH SWINGABLE GUARDRAIL -

REFER TO DETAIL 3/A-416.1.

KN9 CENTER WALL ON COLUMN CENTERLINE

KN10 GRAPHIC WALL. SEE DETAILS ON PLATE A-505.1.

KN11 ALIGN THESE TWO WALL FACES

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

279105

A-104.1

FI

R

ST

F

LO

O

R P

LA

N

ZO

N E

A

TR

AI

N

IN

G S

U

PP

O R

T

FA

C

IL

IT

Y

AR

M

Y

AV

IA

TI

O N

FO

R

T R

U C

KE

R

, A

LA

BA

M

A M

O

BI

LE

D

IS

TR

IC

T

KN

IG

H T

AR

C

H

IT

EC

TS

, I N

C

P

ER

IM

ET

ER

P

AR

K

D R

IV

E, S U

IT

E

AT

LA

N

TA

G A

JS

W

JS

W

JS

W

JC

K

D

EC

W

8-

-D

-0

W

8F

6F Y1

AS BUILT

1/8" = 1'-0"A-104.1

1 FIRST FLOOR PLAN - ZONE A

PLAN NORTH

04 8 16268

SCALE: 1/8"=1'-0"

KEY PLAN

ZONE A

ZONE B

ZONE C

A

B

B

C

C

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

A

AM

EN

D

. 0

7, R

EP

LA

C

ED

D R

AW

IN

G

JU

N E

B

AM

EN

D

M

EN

T

FE

B

C

AS

I N

O . 0

SE

PT

C

D

E

1 2 3 4

A-302.1

A-301.1

LOBBY

3C

103A

3B

E.5

3.51.5

A-302.1

8'

7"

2.5

FEB FEC

FEB

FEC

KN2

KN7

1'

4"

MATCHLINEMATCHLINE

MATCH

LINE

MATCH

LINE

O F

ST

U

D

6' -8

" C O

L C

L

TO

F

AC

E

O F

ST

U

D

6' -8

" C O

L C

L

TO

F

AC

E

69' - 0" 70' - 0" 69' - 0"

COL CENTERLINE TO FACE OF STUD

40' - 1 3/8"

2' - 10"

A-404.11

10' - 1 3/8"

KN9

KN9

NOTE:

EXISTING CH-47D ARTIFACT MUST BE PLACED INSIDE OF THE BUILDING

PRIOR TO INSTALLATION OF ALL STRUCTURE AND EXTERIOR METAL

PANELS BETWEEN COLUMNS 1D AND 1E. THE ARTIFACT REQUIRES A

24'-0" HEIGHT CLEARANCE. ARTIFACT MUST BE PROTECTED DURING

REMAINING CONSTRUCTION. FINAL PLACEMENT OF ARTIFACT WILL BE

BETWEEN COLUMN LINES D & E AND 1 & 3.

(E D

G E

O F

W P-

2)

(E

D G

E O

F W

P- 2)

8'

0" 8'

0"

8'

0" 8'

0"

A-504.1

A-504.1

W4W4

W2

DISPLAY

DISPLAY

CG2

CG2

DS

DS

DS

DS

DS

5'

1/

2"

DS

D

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

279106

A-105.1

FI

R

ST

F

LO

O

R P

LA

N

ZO

N E

B

TR

AI

N

IN

G S

U

PP

O R

T

FA

C

IL

IT

Y

AR

M

Y

AV

IA

TI

O N

FO

R

T R

U C

KE

R

, A

LA

BA

M

A M

O

BI

LE

D

IS

TR

IC

T

KN

IG

H T

AR

C

H

IT

EC

TS

, I N

C

P

ER

IM

ET

ER

P

AR

K

D R

IV

E, S U

IT

E

AT

LA

N

TA

G A

JS

W

JS

W

JS

W

JC

K

D

EC

W

8-

-D

-0

W

8F

6F Y1

AS BUILT

1/8" = 1'-0"A-105.1

1 FIRST FLOOR PLAN - ZONE B 04 8 16268

SCALE: 1/8"=1'-0"

PLAN NORTH

KEY PLAN

ZONE A

ZONE B

ZONE C

NOTE:

REFER TO PLATE A-104.1 FOR KEY NOTES

AND LEGEND.

A

B

C

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

A

AM

EN

D

. 0

7, R

EP

LA

C

ED

D R

AW

IN

G

JU

N E

B

AM

EN

D

M

EN

T

FE

B

C

AS

I N

O . 0

SE

PT

D

AS

I N

O . 0

D

EC

F

G

1 2 3 4

A-302.1

STAIR

S4

STAIR

S3

3B

S4A

S4B

S3A

S3B

F.5

E.5

3.51.5

A-302.1

35' - 2" 150' - 0" 35' - 2"

8'

2"

3'

4"

3' - 4"

8'

2"

3'

4"

3' - 4"

A-412.1

A-412.1

2.5

FEC

FECFECCW3 CW3

MATCH

LINE

MATCH

LINE

39' - 0" 30' - 0" 35' - 0" 35' - 0" 30' - 0" 39' - 0"6' - 2" 6' - 2"

KN9

LINE OF MEZZANININE

ABOVE

W2 W2

W2

WIND COLUMN (TYP.)X-BRACING (TYP.)

CG2

DISPLAY

DS

DS

DS

DS DS DS DS

DS

KEY NOTES LEGEND

FEC SEMI-RECESSED FIRE EXTINGUISHER CABINET.

REFER TO DETAIL 3/A-535.1.

FEB WALL MOUNTED FIRE EXTINGUISHER BRACKET.

MOUNT AT 48" AFF.

DS DOWNSPOUT

BEJ BRICK EXPANSION JOINT - REFER TO 3/A-522.1

CJ CONTROL JOINT - SEE STRUCT FOR DETAIL

CG1 VINYL CORNER GUARD - SEE 2/A-511.1

CG2 ALUMINUM CORNER GUARD - SEE 10/A-511.1

EC1 VINYL END CAP - SEE 8/A-511.1

EC2 ALUMINUM END CAP - SEE 9/A-511.1

KN1 MOP SINK - SEE PLUMBING

KN2 ENTRANCE FLOOR MAT (EM-1) CENTERED ON

DOOR FRAME.

KN3 ELECTRIC WATER COOLER

KN4 PROVIDE KNOX BOX - REFER TO DETAIL 1/A-502.1

KN5 PROVIDE 5/8" STAINLESS STEEL EYELETS

W/ 2" DIA. EYE AT 5'-0" A.F.F. SPACING SHALL BE

COORDINATED WITH CONTRACTING OFFICER.

KN6 42" HIGH GUARDRAIL - REFER TO DETAILS ON A-416.1.

KN7 SCREEN WALL WITH METAL PERFORATED IMAGE

PANELS. SEE PLATE A-505.1 FOR DETAILS.

CONSTRUCTION SYSTEMS AND WALL TYPES - REFER TO

PLATES A-001.1 THRU A-002.1.

ROOM NUMBER

WINDOW OR LOUVER TYPE - REFER TO WINDOW AND

LOUVER TYPES AND DETAILS ON PLATES A-602.1

1-HOUR RATED PARTITION

X

KN8 42" REMOVABLE HIGH SWINGABLE GUARDRAIL -

REFER TO DETAIL 3/A-416.1.

KN9 CENTER WALL ON COLUMN CENTERLINE

KN10 GRAPHIC WALL. SEE DETAILS ON PLATE A-505.1.

KN11 ALIGN THESE TWO WALL FACES

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

279107

A-106.1

FI

R

ST

F

LO

O

R P

LA

N

ZO

N E

C

TR

AI

N

IN

G S

U

PP

O R

T

FA

C

IL

IT

Y

AR

M

Y

AV

IA

TI

O N

FO

R

T R

U C

KE

R

, A

LA

BA

M

A M

O

BI

LE

D

IS

TR

IC

T

KN

IG

H T

AR

C

H

IT

EC

TS

, I N

C

P

ER

IM

ET

ER

P

AR

K

D R

IV

E, S U

IT

E

AT

LA

N

TA

G A

JS

W

JS

W

JS

W

JC

K

D

EC

W

8-

-D

-0

W

8F

6F Y1

AS BUILT

1/8" = 1'-0"A-106.1

1 FIRST FLOOR PLAN - ZONE C

PLAN NORTH

04 8 16268

SCALE: 1/8"=1'-0"

KEY PLAN

ZONE A

ZONE B

ZONE C

A

B

B

C

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

A

AM

EN

D

. 0

7, R

EP

LA

C

ED

D R

AW

IN

G

JU

N E

B

AM

EN

D

M

EN

T

FE

B

C

AS

I N

O . 0

SE

PT

C

1 2 3

A-301.1

A-302.1

SUPPLY

122M

ARTIFACTS

121M

A-410.1

S2C

122M

S1C

STAIR

S2

STAIR

S1

A.5

3.51.5

A-302.1

A-411.1

2.5

FEC FEC

FEB

CW2

CW3 CW3

CW2

35' - 2" 150' - 0" 35' - 2"

18' - 11 1/2" 11' - 8"

6'

3" 2'

5/ 8"

SECOND FLOOR

OPENING ABOVE

SECOND FLOOR

OPENING ABOVE

OPEN

TO

BELOW

KN6

OPEN

OPEN

OPEN

OPEN

2' - 5" 39' - 0" 30' - 0" 35' - 0" 35' - 0" 30' - 0"

KN6KN6 KN6

KN8

24' - 3" 20' - 0" (2 SWING OPEN SECTIONS) 24' - 3"

7 1/2" 1' - 0"

A-504.1

OPEN

TO

BELOW

OPEN

TO

BELOW

W1

W1W1

W2A W2A

W1

CG2 CG2

CG2 CG2

17'-7"

17' - 7" 6'

5/ 8"

/8

4' - 11 3/8"

8"

DS

DS

KEY NOTES LEGEND

FEC SEMI-RECESSED FIRE EXTINGUISHER CABINET.

REFER TO DETAIL 3/A-535.1.

FEB WALL MOUNTED FIRE EXTINGUISHER BRACKET.

MOUNT AT 48" AFF.

DS DOWNSPOUT

BEJ BRICK EXPANSION JOINT - REFER TO 3/A-522.1

CJ CONTROL JOINT - SEE STRUCT FOR DETAIL

CG1 VINYL CORNER GUARD - SEE 2/A-511.1

CG2 ALUMINUM CORNER GUARD - SEE 10/A-511.1

EC1 VINYL END CAP - SEE 8/A-511.1

EC2 ALUMINUM END CAP - SEE 9/A-511.1

KN1 MOP SINK - SEE PLUMBING

KN2 ENTRANCE FLOOR MAT (EM-1) CENTERED ON

DOOR FRAME.

KN3 ELECTRIC WATER COOLER

KN4 PROVIDE KNOX BOX - REFER TO DETAIL 1/A-502.1

KN5 PROVIDE 5/8" STAINLESS STEEL EYELETS

W/ 2" DIA. EYE AT 5'-0" A.F.F. SPACING SHALL BE

COORDINATED WITH CONTRACTING OFFICER.

KN6 42" HIGH GUARDRAIL - REFER TO DETAILS ON A-416.1.

KN7 SCREEN WALL WITH METAL PERFORATED IMAGE

PANELS. SEE PLATE A-505.1 FOR DETAILS.

CONSTRUCTION SYSTEMS AND WALL TYPES - REFER TO

PLATES A-001.1 THRU A-002.1.

ROOM NUMBER

WINDOW OR LOUVER TYPE - REFER TO WINDOW AND

LOUVER TYPES AND DETAILS ON PLATES A-602.1

1-HOUR RATED PARTITION

X

KN8 42" REMOVABLE HIGH SWINGABLE GUARDRAIL -

REFER TO DETAIL 3/A-416.1.

KN9 CENTER WALL ON COLUMN CENTERLINE

KN10 GRAPHIC WALL. SEE DETAILS ON PLATE A-505.1.

KN11 ALIGN THESE TWO WALL FACES

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

279108

A-107.1

M

EZ

ZA

N

IN

E

FL

O

O R

P

LA

N

ZO

N

E A

TR

AI

N

IN

G S

U

PP

O R

T

FA

C

IL

IT

Y

AR

M

Y

AV

IA

TI

O N

FO

R

T R

U C

KE

R

, A

LA

BA

M

A M

O

BI

LE

D

IS

TR

IC

T

KN

IG

H T

AR

C

H

IT

EC

TS

, I N

C

P

ER

IM

ET

ER

P

AR

K

D R

IV

E, S U

IT

E

AT

LA

N

TA

G A

JS

W

JS

W

JS

W

JC

K

D

EC

W

8-

-D

-0

W

8F

6F Y1

AS BUILT

1/8" = 1'-0"A-107.1

1 MEZZANINE FLOOR PLAN - ZONE A

04 8 16268

SCALE: 1/8"=1'-0"

PLAN NORTH

KEY PLAN

ZONE A

ZONE B

ZONE C

A

B B

C

C

C CD

D

D

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

A

AM

EN

D

. 0

7, R

EP

LA

C

ED

D R

AW

IN

G

JU

N E

B

AM

EN

D

M

EN

T

D

EC

C

AM

EN

D

M

EN

T

FE

B

D

AS

I N

O . 0

N O

V

1 2 3

A-302.1

F.5

E.5

3.51.5

A-302.1

2.5

S4C S3C

ARTIFACTS

123M

KN6KN6

KN6

24' - 3" 20' - 0" (2 SWING OPEN SECTIONS) 24' - 3"

KN6

KN8

A-412.1

A-412.1

FEC FEC

A-416.1

X-BRACING (TYP.) WIND COLUMN (TYP.)

W1

W2A

W1

W2A

W1

W1

W2

W1

W1

W2

DS

DS

KEY NOTES LEGEND

FEC SEMI-RECESSED FIRE EXTINGUISHER CABINET.

REFER TO DETAIL 3/A-535.1.

FEB WALL MOUNTED FIRE EXTINGUISHER BRACKET.

MOUNT AT 48" AFF.

DS DOWNSPOUT

BEJ BRICK EXPANSION JOINT - REFER TO 3/A-522.1

CJ CONTROL JOINT - SEE STRUCT FOR DETAIL

CG1 VINYL CORNER GUARD - SEE 2/A-511.1

CG2 ALUMINUM CORNER GUARD - SEE 10/A-511.1

EC1 VINYL END CAP - SEE 8/A-511.1

EC2 ALUMINUM END CAP - SEE 9/A-511.1

KN1 MOP SINK - SEE PLUMBING

KN2 ENTRANCE FLOOR MAT (EM-1) CENTERED ON

DOOR FRAME.

KN3 ELECTRIC WATER COOLER

KN4 PROVIDE KNOX BOX - REFER TO DETAIL 1/A-502.1

KN5 PROVIDE 5/8" STAINLESS STEEL EYELETS

W/ 2" DIA. EYE AT 5'-0" A.F.F. SPACING SHALL BE

COORDINATED WITH CONTRACTING OFFICER.

KN6 42" HIGH GUARDRAIL - REFER TO DETAILS ON A-416.1.

KN7 SCREEN WALL WITH METAL PERFORATED IMAGE

PANELS. SEE PLATE A-505.1 FOR DETAILS.

CONSTRUCTION SYSTEMS AND WALL TYPES - REFER TO

PLATES A-001.1 THRU A-002.1.

ROOM NUMBER

WINDOW OR LOUVER TYPE - REFER TO WINDOW AND

LOUVER TYPES AND DETAILS ON PLATES A-602.1

1-HOUR RATED PARTITION

X

KN8 42" REMOVABLE HIGH SWINGABLE GUARDRAIL -

REFER TO DETAIL 3/A-416.1.

KN9 CENTER WALL ON COLUMN CENTERLINE

KN10 GRAPHIC WALL. SEE DETAILS ON PLATE A-505.1.

KN11 ALIGN THESE TWO WALL FACES

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

279109

A-108.1

M

EZ

ZA

N

IN

E

FL

O

O R

P

LA

N

ZO

N

E C

TR

AI

N

IN

G S

U

PP

O R

T

FA

C

IL

IT

Y

AR

M

Y

AV

IA

TI

O N

FO

R

T R

U C

KE

R

, A

LA

BA

M

A M

O

BI

LE

D

IS

TR

IC

T

KN

IG

H T

AR

C

H

IT

EC

TS

, I N

C

P

ER

IM

ET

ER

P

AR

K

D R

IV

E, S U

IT

E

AT

LA

N

TA

G A

JS

W

JS

W

JS

W

JC

K

D

EC

W

8-

-D

-0

W

8F

6F Y1

AS BUILT

1/8" = 1'-0"A-108.1

1 MEZZANINE FLOOR PLAN - ZONE C

KEY PLAN

ZONE A

ZONE B

ZONE C

04 8 16268

SCALE: 1/8"=1'-0"

PLAN NORTH

A

B

B

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

A

AM

EN

D

. 0

7, R

EP

LA

C

ED

D R

AW

IN

G

JU

N E

B

AM

EN

D

M

EN

T

FE

B

C

1 2 3

A-301.1

A-302.1

STORAGE

COMM

JANITOR

MEN

WOMEN

MECH

REFERENCE

LIBRARY

BREAKROOM

CORRIDOR

CONFERENCE

OFFICE

209A

OFFICE

CLASSROOM

STORAGE

LOBBY

EMCS

A-401.1

A-410.1

CORRIDOR

CORRIDOR

C O

R R

ID

O

R

201 202

S1D206B

6A

5A

7A

209A

210B

0A

5B

9A

219B

S2D

STAIR

S2

STAIR

S1

A.5

3.51.5

A-302.1

A-411.1

A-403.1

2.5

KN1

KN6

KN8

OPEN

TO BELOW

FECFEC

FEC

FEB

8 8

8 8

8 8

CW2 CW2

CW3

CW3

CW1

40' - 9 3/8" 9' - 6 5/8" 19' - 0" 6' - 7" 20' - 0" 34' - 8 1/2"

1/

8"

0"

10' - 8"10' - 0 1/2"

SF1

10' - 0" 50' - 0"

4' - 7 7/8"

KN9

KN9

35' - 2" 150' - 0" 35' - 2"

/8

4'

7/

8"

10' - 0" 10' - 8"

2' - 5" 39' - 0" 30' - 0" 35' - 0" 35' - 0" 30' - 0"

MATCHLINE MATCHLINE

DISPLAY

DISPLAY

OFFICE

209BRECEPTION

208A

207B

A-510.1

A-403.1 2

A-510.1

A-510.1

A-510.1

A-510.1

A-510.1

SIM.

KN6

KN6

KN6

KN8

1"

(2 S

W

IN

G O

PE

N

S

EC

TI

O

N S)

10' - 0"

1"

(2 S

W

IN

G O

PE

N

S

EC

TI

O

N S)

9'

/4

18' - 7 1/8"

SF3

SF2

209B

A-510.1

KN11

X-BRACING (TYP)

WIND COLUMN (TYP)

W1

W1W1

W1

W4

KN11

X-BRACING (TYP)

WIND COLUMN (TYP)

CG1

EC1

CG1

CG1

CG1

CG1

W2A W2A

DS

DS

KEY NOTES LEGEND

FEC SEMI-RECESSED FIRE EXTINGUISHER CABINET.

REFER TO DETAIL 3/A-535.1.

FEB WALL MOUNTED FIRE EXTINGUISHER BRACKET.

MOUNT AT 48" AFF.

DS DOWNSPOUT

BEJ BRICK EXPANSION JOINT - REFER TO 3/A-522.1

CJ CONTROL JOINT - SEE STRUCT FOR DETAIL

CG1 VINYL CORNER GUARD - SEE 2/A-511.1

CG2 ALUMINUM CORNER GUARD - SEE 10/A-511.1

EC1 VINYL END CAP - SEE 8/A-511.1

EC2 ALUMINUM END CAP - SEE 9/A-511.1

KN1 MOP SINK - SEE PLUMBING

KN2 ENTRANCE FLOOR MAT (EM-1) CENTERED ON

DOOR FRAME.

KN3 ELECTRIC WATER COOLER

KN4 PROVIDE KNOX BOX - REFER TO DETAIL 1/A-502.1

KN5 PROVIDE 5/8" STAINLESS STEEL EYELETS

W/ 2" DIA. EYE AT 5'-0" A.F.F. SPACING SHALL BE

COORDINATED WITH CONTRACTING OFFICER.

KN6 42" HIGH GUARDRAIL - REFER TO DETAILS ON A-416.1.

KN7 SCREEN WALL WITH METAL PERFORATED IMAGE

PANELS. SEE PLATE A-505.1 FOR DETAILS.

CONSTRUCTION SYSTEMS AND WALL TYPES - REFER TO

PLATES A-001.1 THRU A-002.1.

ROOM NUMBER

WINDOW OR LOUVER TYPE - REFER TO WINDOW AND

LOUVER TYPES AND DETAILS ON PLATES A-602.1

1-HOUR RATED PARTITION

X

KN8 42" REMOVABLE HIGH SWINGABLE GUARDRAIL -

REFER TO DETAIL 3/A-416.1.

KN9 CENTER WALL ON COLUMN CENTERLINE

KN10 GRAPHIC WALL. SEE DETAILS ON PLATE A-505.1.

KN11 ALIGN THESE TWO WALL FACES

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

279110

A-109.1

SE

C

O N

D F

LO

O

R P

LA

N

ZO

N E

A

TR

AI

N

IN

G S

U

PP

O R

T

FA

C

IL

IT

Y

AR

M

Y

AV

IA

TI

O N

FO

R

T R

U C

KE

R

, A

LA

BA

M

A M

O

BI

LE

D

IS

TR

IC

T

KN

IG

H T

AR

C

H

IT

EC

TS

, I N

C

P

ER

IM

ET

ER

P

AR

K

D R

IV

E, S U

IT

E

AT

LA

N

TA

G A

JS

W

JS

W

JS

W

JC

K

D

EC

W

8-

-D

-0

W

8F

6F Y1

AS BUILT

1/8" = 1'-0"A-109.1

1 SECOND FLOOR PLAN - ZONE A

PLAN NORTH

04 8 16268

SCALE: 1/8"=1'-0"

KEY PLAN

ZONE A

ZONE B

ZONE C

A

B

B

B

B

C

C

C

D

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

A

AM

EN

D

. 0

7, R

EP

LA

C

ED

D R

AW

IN

G

JU

N E

B

AM

EN

D

M

EN

T

FE

B

C

AS

I N

O . 0

N O

V

D

AS

I N

O . 0

SE

PT

E

1 2 3 4

A-302.1

A-301.1

E.5

3.51.5

A-302.1

2.5

FEB

FEB

FEB

FEB

KN6

KN6

KN6

OPEN

TO

BELOW

2' - 5" 39' - 0" 30' - 0" 35' - 0" 35' - 0" 30' - 0" 39' - 0" 2' - 5"

MATCHLINE MATCHLINE

MATCHLINE MATCHLINE

68' - 6"

SL

O

PE

/4 " P

ER

F

O O

T

SL

O

PE

/4

" P

ER

F O

O T

PVC ROOF MEMBRANE ON

RIGID INSULATION OVER

METAL DECK (ROOF TYPE R2)

KN10

A-416.1

A-312.1

W1

W1W1

W1

STAINLESS STEEL

SPLASH PAN

STAINLESS STEEL

SPLASH PAN

DS

DS

B

BB

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

279111

A-110.1

SE

C

O N

D F

LO

O

R P

LA

N

ZO

N E

B

TR

AI

N

IN

G S

U

PP

O R

T

FA

C

IL

IT

Y

AR

M

Y

AV

IA

TI

O N

FO

R

T R

U C

KE

R

, A

LA

BA

M

A M

O

BI

LE

D

IS

TR

IC

T

KN

IG

H T

AR

C

H

IT

EC

TS

, I N

C

P

ER

IM

ET

ER

P

AR

K

D R

IV

E, S U

IT

E

AT

LA

N

TA

G A

JS

W

JS

W

JS

W

JC

K

D

EC

W

8-

-D

-0

W

8F

6F Y1

AS BUILT

1/8" = 1'-0"A-110.1

1 SECOND FLOOR PLAN - ZONE B

04 8 16268

SCALE: 1/8"=1'-0"KEY PLAN

ZONE A

ZONE B

ZONE C

PLAN NORTH

NOTE:

REFER TO PLATE A-109.1 FOR KEY NOTES

AND LEGEND.

A

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

A

AM

EN

D

. 0

7, R

EP

LA

C

ED

D R

AW

IN

G

JU

N E

B

AS

I N O

. 0

D

EC

2 3

A-302.1

S4D S3D

STAIR

S4

STAIR

S3

F.5

E.5

3.51.5

A-302.1

A-412.1

A-412.1

2.5

FEB

FEC FEC

MATCHLINE MATCHLINE

35' - 2" 150' - 0" 35' - 2"

2' - 5" 39' - 0" 30' - 0" 35' - 0" 35' - 0" 30' - 0"

W1

W2A W2A

W1

W1

W1 W1

W2W2

W1

DS

DS

KEY NOTES LEGEND

FEC SEMI-RECESSED FIRE EXTINGUISHER CABINET.

REFER TO DETAIL 3/A-535.1.

FEB WALL MOUNTED FIRE EXTINGUISHER BRACKET.

MOUNT AT 48" AFF.

DS DOWNSPOUT

BEJ BRICK EXPANSION JOINT - REFER TO 3/A-522.1

CJ CONTROL JOINT - SEE STRUCT FOR DETAIL

CG1 VINYL CORNER GUARD - SEE 2/A-511.1

CG2 ALUMINUM CORNER GUARD - SEE 10/A-511.1

EC1 VINYL END CAP - SEE 8/A-511.1

EC2 ALUMINUM END CAP - SEE 9/A-511.1

KN1 MOP SINK - SEE PLUMBING

KN2 ENTRANCE FLOOR MAT (EM-1) CENTERED ON

DOOR FRAME.

KN3 ELECTRIC WATER COOLER

KN4 PROVIDE KNOX BOX - REFER TO DETAIL 1/A-502.1

KN5 PROVIDE 5/8" STAINLESS STEEL EYELETS

W/ 2" DIA. EYE AT 5'-0" A.F.F. SPACING SHALL BE

COORDINATED WITH CONTRACTING OFFICER.

KN6 42" HIGH GUARDRAIL - REFER TO DETAILS ON A-416.1.

KN7 SCREEN WALL WITH METAL PERFORATED IMAGE

PANELS. SEE PLATE A-505.1 FOR DETAILS.

CONSTRUCTION SYSTEMS AND WALL TYPES - REFER TO

PLATES A-001.1 THRU A-002.1.

ROOM NUMBER

WINDOW OR LOUVER TYPE - REFER TO WINDOW AND

LOUVER TYPES AND DETAILS ON PLATES A-602.1

1-HOUR RATED PARTITION

X

KN8 42" REMOVABLE HIGH SWINGABLE GUARDRAIL -

REFER TO DETAIL 3/A-416.1.

KN9 CENTER WALL ON COLUMN CENTERLINE

KN10 GRAPHIC WALL. SEE DETAILS ON PLATE A-505.1.

KN11 ALIGN THESE TWO WALL FACES

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

279112

A-111.1

SE

C

O N

D F

LO

O

R P

LA

N

ZO

N E

C

TR

AI

N

IN

G S

U

PP

O R

T

FA

C

IL

IT

Y

AR

M

Y

AV

IA

TI

O N

FO

R

T R

U C

KE

R

, A

LA

BA

M

A M

O

BI

LE

D

IS

TR

IC

T

KN

IG

H T

AR

C

H

IT

EC

TS

, I N

C

P

ER

IM

ET

ER

P

AR

K

D R

IV

E, S U

IT

E

AT

LA

N

TA

G A

JS

W

JS

W

JS

W

JC

K

D

EC

W

8-

-D

-0

W

8F

6F Y1

AS BUILT

1/8" = 1'-0"A-111.1

1 SECOND FLOOR PLAN - ZONE C

04 8 16268

SCALE: 1/8"=1'-0"

KEY PLAN

ZONE A

ZONE B

ZONE C

PLAN NORTH

A

B

B

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

A

AM

EN

D

. 0

7, R

EP

LA

C

ED

D R

AW

IN

G

JU

N E

B

AM

EN

D

M

EN

T

FE

B

C

1 2 3

A-301.1

A-302.1

A.5

3.51.5

A-302.1

2.5

111 110

S2 S1

106 105

OPEN

TO

ABOVE

A.F.F.9' - 0" A.F.F.9' - 0"A.F.F.9' - 0"

KN1

KN2

KN2

A.F.F.10' - 0"

KN2

MEZZANINE ABOVE

GENERAL NOTES

1. DO NOT SCALE DRAWINGS.

2. CENTER CEILING GRIDS IN EACH ROOM AS INDICATED.

3. ALL PENETRATIONS THROUGH CEILING, INCLUDING BUT NOT LIMITED TO MECHANICAL

GRILLES, EXHAUST FANS, LIGHT FIXTURES, AND SPRINKLER HEADS, SHALL BE CENTERED

IN THE CEILING TILE.

4. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.

5. FOR AREAS WHERE NO CEILING FINISH IS INDICATED, THE CEILING IS OPEN TO

STRUCTURE.

6. ALL EXPOSED STRUCTURE SHALL BE PAINTED PNT-6.

7. ALL EXPOSED MECHANICAL AND ELECTRICAL EQUIPMENT AND ASSOCIATED

APPURTENANCES SHALL BE PAINTED PT-1 UNLESS OTHERWISE REQUIRED BY CODE.

8. REFER TO INTERIOR DRAWINGS FOR ADDITIONAL FINISH REQUIREMENTS.

LEGEND

A.F.F.9'-0" CEILING HEIGHT, ABOVE FINISH FLOOR

101 ROOM NUMBER

GYP. BD. CEILING

2 X 4 LIGHT FIXTURE

2 x 2 LIGHT FIXTURE

SUSPENDED STRIP LIGHT

RETURN AIR GRILLE

SUPPLY AIR GRILLE

EXHAUST AIR GRILLE

2' x 2' ACT CEILING

EXIT SIGN

2 X 4 LIGHT FIXTURE W/ EMERGENCY

POWER

SUSPENDED PENDANT FIXTURE

SUSPENDED PENDANT FIXTURE W/

EMERGENCY POWER

SUSPENDED STRIP LIGHT W/

EMERGENCY POWER

WALL MOUNTED FIXTURE W/

EMERGENCY POWER

C1 CEILING TYPE. SEE PLATE A-001.1 FOR

DETAILS

2 x 2 LIGHT FIXTURE W/

EMERGENCY POWER

KEY NOTES

KN1 BULKHEAD - REFER TO DETAIL

4/A-511.1

KN2 EXPOSED DUCTWORK - TYP.

RECESSED COMPACT FIXTURE

EXTERIOR WALL MOUNTED FIXTURE

W/ BATTERY PACK

UNIT HEATER

1-HOUR RATED PARTITION

UNDERSIDE OF METAL DECK

ABOVE - PAINT PNT-6

LED INDUSTRIAL HIGH BAY FIXTURE

W/ EMERCENCY BACKUP

LED INDUSTRIAL HIGH BAY FIXTURE

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

279113

A-121.1

FI

R

ST

F

LO

O

R R

EF

LE

C

TE

D C

EI

LI

N G

P

LA

N

ZO

N

E A

TR

AI

N

IN

G S

U

PP

O R

T

FA

C

IL

IT

Y

AR

M

Y

AV

IA

TI

O N

FO

R

T R

U C

KE

R

, A

LA

BA

M

A M

O

BI

LE

D

IS

TR

IC

T

KN

IG

H T

AR

C

H

IT

EC

TS

, I N

C

P

ER

IM

ET

ER

P

AR

K

D R

IV

E, S U

IT

E

AT

LA

N

TA

G A

JS

W

JS

W

JS

W

JC

K

D

EC

W

8-

-D

-0

W

8F

6F Y1

AS BUILT

1/8" = 1'-0"A-121.1

1 FIRST FLOOR CEILING PLAN - ZONE A

04 8 16268

SCALE: 1/8"=1'-0"

PLAN NORTH

KEY PLAN

ZONE A

ZONE B

ZONE C

A

B

B

C

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

A

AM

EN

D

. 0

7, R

EP

LA

C

ED

D R

AW

IN

G

JU

N E

B

AS

I N O

. 0

SE

PT

C

AS

I N O

. 0

D

EC

E

1 2 3 4

A-302.1

A-301.1

E.5

3.51.5

A-302.1

2.5

OPEN

TO ABOVE

KN2

KN2

KN2

A-312.1

METAL PANEL

SOFFIT

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

279114

A-122.1

FI

R

ST

F

LO

O

R R

EF

LE

C

TE

D C

EI

LI

N G

P

LA

N

ZO

N

E B

TR

AI

N

IN

G S

U

PP

O R

T

FA

C

IL

IT

Y

AR

M

Y

AV

IA

TI

O N

FO

R

T R

U C

KE

R

, A

LA

BA

M

A M

O

BI

LE

D

IS

TR

IC

T

KN

IG

H T

AR

C

H

IT

EC

TS

, I N

C

P

ER

IM

ET

ER

P

AR

K

D R

IV

E, S U

IT

E

AT

LA

N

TA

G A

JS

W

JS

W

JS

W

JC

K

D

EC

W

8-

-D

-0

W

8F

6F Y1

AS BUILT

1/8" = 1'-0"A-122.1

1 FIRST FLOOR CEILING PLAN - ZONE B PLAN NORTH

04 8 16268

SCALE: 1/8"=1'-0"KEY PLAN

ZONE A

ZONE B

ZONE C

NOTE:

REFER TO PLATE A-121.1 FOR KEY NOTES

AND LEGEND.

A

B

C

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

A

AM

EN

D

. 0

7, R

EP

LA

C

ED

D R

AW

IN

G

JU

N E

B

AM

EN

D

M

EN

T

FE

B

C

AS

I N

O . 0

SE

PT

1 2 3 41 A-302.1

F.5

E.5

3.51.5 2 A-302.1

____________________________________________________2.5

KN2

KN2

MEZZANINE ABOVE

GENERAL NOTES

1. DO NOT SCALE DRAWINGS.

2. CENTER CEILING GRIDS IN EACH ROOM AS INDICATED.

3. ALL PENETRATIONS THROUGH CEILING, INCLUDING BUT NOT LIMITED TO MECHANICAL

GRILLES, EXHAUST FANS, LIGHT FIXTURES, AND SPRINKLER HEADS, SHALL BE CENTERED

IN THE CEILING TILE.

4. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.

5. FOR AREAS WHERE NO CEILING FINISH IS INDICATED, THE CEILING IS OPEN TO

STRUCTURE.

6. ALL EXPOSED STRUCTURE SHALL BE PAINTED PNT-6.

7. ALL EXPOSED MECHANICAL AND ELECTRICAL EQUIPMENT AND ASSOCIATED

APPURTENANCES SHALL BE PAINTED PT-1 UNLESS OTHERWISE REQUIRED BY CODE.

8. REFER TO INTERIOR DRAWINGS FOR ADDITIONAL FINISH REQUIREMENTS.

LEGEND

A.F.F.9'-0" CEILING HEIGHT, ABOVE FINISH FLOOR

101 ROOM NUMBER

GYP. BD. CEILING

2 X 4 LIGHT FIXTURE

2 x 2 LIGHT FIXTURE

SUSPENDED STRIP LIGHT

RETURN AIR GRILLE

SUPPLY AIR GRILLE

EXHAUST AIR GRILLE

2' x 2' ACT CEILING

EXIT SIGN

2 X 4 LIGHT FIXTURE W/ EMERGENCY

POWER

SUSPENDED PENDANT FIXTURE

SUSPENDED PENDANT FIXTURE W/

EMERGENCY POWER

SUSPENDED STRIP LIGHT W/

EMERGENCY POWER

WALL MOUNTED FIXTURE W/

EMERGENCY POWER

C1 CEILING TYPE. SEE PLATE A-001.1 FOR

DETAILS

2 x 2 LIGHT FIXTURE W/

EMERGENCY POWER

KEY NOTES

KN1 BULKHEAD - REFER TO DETAIL

4/A-511.1

KN2 EXPOSED DUCTWORK - TYP.

RECESSED COMPACT FIXTURE

EXTERIOR WALL MOUNTED FIXTURE

W/ BATTERY PACK

UNIT HEATER

1-HOUR RATED PARTITION

UNDERSIDE OF METAL DECK

ABOVE - PAINT PNT-6

LED INDUSTRIAL HIGH BAY FIXTURE

W/ EMERCENCY BACKUP

LED INDUSTRIAL HIGH BAY FIXTURE

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

279115

A-123.1

FI

R

ST

F

LO

O

R R

EF

LE

C

TE

D C

EI

LI

N G

P

LA

N

ZO

N

E C

TR

AI

N

IN

G S

U

PP

O R

T

FA

C

IL

IT

Y

AR

M

Y

AV

IA

TI

O N

FO

R

T R

U C

KE

R

, A

LA

BA

M

A M

O

BI

LE

D

IS

TR

IC

T

KN

IG

H T

AR

C

H

IT

EC

TS

, I N

C

P

ER

IM

ET

ER

P

AR

K

D R

IV

E, S U

IT

E

AT

LA

N

TA

G A

JS

W

JS

W

JS

W

JC

K

D

EC

W

8-

-D

-0

W

8F

6F Y1

AS BUILT

1/8" = 1'-0"A-123.1

1 FIRST FLOOR CEILING PLAN - ZONE C

PLAN NORTH

04 8 16268

SCALE: 1/8"=1'-0"

KEY PLAN

ZONE A

ZONE B

ZONE C

A

AS

I N O

. 0

O

T

C

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

A

AM

EN

D

. 0

7, R

EP

LA

C

ED

D R

AW

IN

G

JU

N E

B

AS

I N O

. 0

SE

PT

C

AS

I N O

. 0

D

EC

C

1 2 3

A-301.1

A-302.1

A-413.1

A.5

3.51.5

A-302.1

2.5

122M A.F.F.10' - 0"

KN2

KN2

KN2KN2

GENERAL NOTES

1. DO NOT SCALE DRAWINGS.

2. CENTER CEILING GRIDS IN EACH ROOM AS INDICATED.

3. ALL PENETRATIONS THROUGH CEILING, INCLUDING BUT NOT LIMITED TO MECHANICAL

GRILLES, EXHAUST FANS, LIGHT FIXTURES, AND SPRINKLER HEADS, SHALL BE CENTERED

IN THE CEILING TILE.

4. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.

5. FOR AREAS WHERE NO CEILING FINISH IS INDICATED, THE CEILING IS OPEN TO

STRUCTURE.

6. ALL EXPOSED STRUCTURE SHALL BE PAINTED PNT-6.

7. ALL EXPOSED MECHANICAL AND ELECTRICAL EQUIPMENT AND ASSOCIATED

APPURTENANCES SHALL BE PAINTED PT-1 UNLESS OTHERWISE REQUIRED BY CODE.

8. REFER TO INTERIOR DRAWINGS FOR ADDITIONAL FINISH REQUIREMENTS.

LEGEND

A.F.F.9'-0" CEILING HEIGHT, ABOVE FINISH FLOOR

101 ROOM NUMBER

GYP. BD. CEILING

2 X 4 LIGHT FIXTURE

2 x 2 LIGHT FIXTURE

SUSPENDED STRIP LIGHT

RETURN AIR GRILLE

SUPPLY AIR GRILLE

EXHAUST AIR GRILLE

2' x 2' ACT CEILING

EXIT SIGN

2 X 4 LIGHT FIXTURE W/ EMERGENCY

POWER

SUSPENDED PENDANT FIXTURE

SUSPENDED PENDANT FIXTURE W/

EMERGENCY POWER

SUSPENDED STRIP LIGHT W/

EMERGENCY POWER

WALL MOUNTED FIXTURE W/

EMERGENCY POWER

C1 CEILING TYPE. SEE PLATE A-001.1 FOR

DETAILS

2 x 2 LIGHT FIXTURE W/

EMERGENCY POWER

KEY NOTES

KN1 BULKHEAD - REFER TO DETAIL

4/A-511.1

KN2 EXPOSED DUCTWORK - TYP.

RECESSED COMPACT FIXTURE

EXTERIOR WALL MOUNTED FIXTURE

W/ BATTERY PACK

UNIT HEATER

1-HOUR RATED PARTITION

UNDERSIDE OF METAL DECK

ABOVE - PAINT PNT-6

LED INDUSTRIAL HIGH BAY FIXTURE

W/ EMERCENCY BACKUP

LED INDUSTRIAL HIGH BAY FIXTURE

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

279116

A-124.1

M

EZ

ZA

N

IN

E

R

EF

LE

C

TE

D

C

EI

LI

N

G P

LA

N

ZO

N E

A

TR

AI

N

IN

G S

U

PP

O R

T

FA

C

IL

IT

Y

AR

M

Y

AV

IA

TI

O N

FO

R

T R

U C

KE

R

, A

LA

BA

M

A M

O

BI

LE

D

IS

TR

IC

T

KN

IG

H T

AR

C

H

IT

EC

TS

, I N

C

P

ER

IM

ET

ER

P

AR

K

D R

IV

E, S U

IT

E

AT

LA

N

TA

G A

JS

W

JS

W

JS

W

JC

K

D

EC

W

8-

-D

-0

W

8F

6F Y1

AS BUILT

1/8" = 1'-0"A-124.1

1 MEZZANINE CEILING PLAN - ZONE A

04 8 16268

SCALE: 1/8"=1'-0"

PLAN NORTH

KEY PLAN

ZONE A

ZONE B

ZONE C

A

B

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

A

AM

EN

D

. 0

7, R

EP

LA

C

ED

D R

AW

IN

G

JU

N E

B

AS

I N O

. 0

D

EC

1 2 3

A-302.1

F.5

E.5

3.51.5

A-302.1

2.5

S4 S3

KN2

KN2

GENERAL NOTES

1. DO NOT SCALE DRAWINGS.

2. CENTER CEILING GRIDS IN EACH ROOM AS INDICATED.

3. ALL PENETRATIONS THROUGH CEILING, INCLUDING BUT NOT LIMITED TO MECHANICAL

GRILLES, EXHAUST FANS, LIGHT FIXTURES, AND SPRINKLER HEADS, SHALL BE CENTERED

IN THE CEILING TILE.

4. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.

5. FOR AREAS WHERE NO CEILING FINISH IS INDICATED, THE CEILING IS OPEN TO

STRUCTURE.

6. ALL EXPOSED STRUCTURE SHALL BE PAINTED PNT-6.

7. ALL EXPOSED MECHANICAL AND ELECTRICAL EQUIPMENT AND ASSOCIATED

APPURTENANCES SHALL BE PAINTED PT-1 UNLESS OTHERWISE REQUIRED BY CODE.

8. REFER TO INTERIOR DRAWINGS FOR ADDITIONAL FINISH REQUIREMENTS.

LEGEND

A.F.F.9'-0" CEILING HEIGHT, ABOVE FINISH FLOOR

101 ROOM NUMBER

GYP. BD. CEILING

2 X 4 LIGHT FIXTURE

2 x 2 LIGHT FIXTURE

SUSPENDED STRIP LIGHT

RETURN AIR GRILLE

SUPPLY AIR GRILLE

EXHAUST AIR GRILLE

2' x 2' ACT CEILING

EXIT SIGN

2 X 4 LIGHT FIXTURE W/ EMERGENCY

POWER

SUSPENDED PENDANT FIXTURE

SUSPENDED PENDANT FIXTURE W/

EMERGENCY POWER

SUSPENDED STRIP LIGHT W/

EMERGENCY POWER

WALL MOUNTED FIXTURE W/

EMERGENCY POWER

C1 CEILING TYPE. SEE PLATE A-001.1 FOR

DETAILS

2 x 2 LIGHT FIXTURE W/

EMERGENCY POWER

KEY NOTES

KN1 BULKHEAD - REFER TO DETAIL

4/A-511.1

KN2 EXPOSED DUCTWORK - TYP.

RECESSED COMPACT FIXTURE

EXTERIOR WALL MOUNTED FIXTURE

W/ BATTERY PACK

UNIT HEATER

1-HOUR RATED PARTITION

UNDERSIDE OF METAL DECK

ABOVE - PAINT PNT-6

LED INDUSTRIAL HIGH BAY FIXTURE

W/ EMERCENCY BACKUP

LED INDUSTRIAL HIGH BAY FIXTURE

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

279117

A-125.1

M

EZ

ZA

N

IN

E

R

EF

LE

C

TE

D

C

EI

LI

N

G P

LA

N

ZO

N E

C

TR

AI

N

IN

G S

U

PP

O R

T

FA

C

IL

IT

Y

AR

M

Y

AV

IA

TI

O N

FO

R

T R

U C

KE

R

, A

LA

BA

M

A M

O

BI

LE

D

IS

TR

IC

T

KN

IG

H T

AR

C

H

IT

EC

TS

, I N

C

P

ER

IM

ET

ER

P

AR

K

D R

IV

E, S U

IT

E

AT

LA

N

TA

G A

JS

W

JS

W

JS

W

JC

K

D

EC

W

8-

-D

-0

W

8F

6F Y1

AS BUILT

1/8" = 1'-0"A-125.1

1 MEZZANINE CEILING PLAN - ZONE C

04 8 16268

SCALE: 1/8"=1'-0"

PLAN NORTH

KEY PLAN

ZONE A

ZONE B

ZONE C

A

B

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

A

AM

EN

D

. 0

7, R

EP

LA

C

ED

D R

AW

IN

G

JU

N E

B

AS

I N O

. 0

D

EC

C

1 2 3 4

A-301.1

A-302.1

A.5

3.51.5

A-302.1

2.5

S2

214 213

212 211

209A

KN1 KN1 KN1

KN2

KN2

S1

A.F.F.12' - 0"

A.F.F.12' - 0"

A.F.F.9' - 0" A.F.F.9' - 0" A.F.F.9' - 0"

PREFINISHED 3" METAL PANEL (MP-1)

SOFFIT SYSTEM

AT WIND COLUMNS PENTRATIONS, CREATE

OPENING WITH SUSPENSION TEE AT ALL (4)

SIDES, WITH 1" CLEARANCE FOR PENETRATING

STRUCTURE - TYP.

PROVIDE GWB SOFFIT @ 9'-0" AFF BETWEEN COLUMNS AT

X-BRACING LOCATIONS IN FINISHED CEILING AREAS. FRAME

RECTANGULAR OPENINGS WHERE STRUCTURAL PENETRATION

OCCURS - TYP.

DOWNSPOUT FROM GUTTER

ABOVE - TYP.

GENERAL NOTES

1. DO NOT SCALE DRAWINGS.

2. CENTER CEILING GRIDS IN EACH ROOM AS INDICATED.

3. ALL PENETRATIONS THROUGH CEILING, INCLUDING BUT NOT LIMITED TO MECHANICAL

GRILLES, EXHAUST FANS, LIGHT FIXTURES, AND SPRINKLER HEADS, SHALL BE CENTERED

IN THE CEILING TILE.

4. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.

5. FOR AREAS WHERE NO CEILING FINISH IS INDICATED, THE CEILING IS OPEN TO

STRUCTURE.

6. ALL EXPOSED STRUCTURE SHALL BE PAINTED PNT-6.

7. ALL EXPOSED MECHANICAL AND ELECTRICAL EQUIPMENT AND ASSOCIATED

APPURTENANCES SHALL BE PAINTED PT-1 UNLESS OTHERWISE REQUIRED BY CODE.

8. REFER TO INTERIOR DRAWINGS FOR ADDITIONAL FINISH REQUIREMENTS.

LEGEND

A.F.F.9'-0" CEILING HEIGHT, ABOVE FINISH FLOOR

101 ROOM NUMBER

GYP. BD. CEILING

2 X 4 LIGHT FIXTURE

2 x 2 LIGHT FIXTURE

SUSPENDED STRIP LIGHT

RETURN AIR GRILLE

SUPPLY AIR GRILLE

EXHAUST AIR GRILLE

2' x 2' ACT CEILING

EXIT SIGN

2 X 4 LIGHT FIXTURE W/ EMERGENCY

POWER

SUSPENDED PENDANT FIXTURE

SUSPENDED PENDANT FIXTURE W/

EMERGENCY POWER

SUSPENDED STRIP LIGHT W/

EMERGENCY POWER

WALL MOUNTED FIXTURE W/

EMERGENCY POWER

C1 CEILING TYPE. SEE PLATE A-001.1 FOR

DETAILS

2 x 2 LIGHT FIXTURE W/

EMERGENCY POWER

KEY NOTES

KN1 BULKHEAD - REFER TO DETAIL

4/A-511.1

KN2 EXPOSED DUCTWORK - TYP.

RECESSED COMPACT FIXTURE

EXTERIOR WALL MOUNTED FIXTURE

W/ BATTERY PACK

UNIT HEATER

1-HOUR RATED PARTITION

UNDERSIDE OF METAL DECK

ABOVE - PAINT PNT-6

LED INDUSTRIAL HIGH BAY FIXTURE

W/ EMERCENCY BACKUP

LED INDUSTRIAL HIGH BAY FIXTURE

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

279118

A-126.1

SE

C

O N

D F

LO

O

R R

EF

LE

C

TE

D C

EI

LI

N G

PL

AN

ZO

N E

A

TR

AI

N

IN

G S

U

PP

O R

T

FA

C

IL

IT

Y

AR

M

Y

AV

IA

TI

O N

FO

R

T R

U C

KE

R

, A

LA

BA

M

A M

O

BI

LE

D

IS

TR

IC

T

KN

IG

H T

AR

C

H

IT

EC

TS

, I N

C

P

ER

IM

ET

ER

P

AR

K

D R

IV

E, S U

IT

E

AT

LA

N

TA

G A

JS

W

JS

W

JS

W

JC

K

D

EC

W

8-

-D

-0

W

8F

6F Y1

AS BUILT

1/8" = 1'-0"A-126.1

1 SECOND FLOOR CEILING PLAN - ZONE A

PLAN NORTH

04 8 16268

SCALE: 1/8"=1'-0"

KEY PLAN

ZONE A

ZONE B

ZONE C

A

B

C

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

A

AM

EN

D

. 0

7, R

EP

LA

C

ED

D R

AW

IN

G

JU

N E

B

AS

I N O

. 0

SE

PT

C

AS

I N O

. 0

D

EC

E

1 2 3 4

A-302.1

A-301.1

E.5

3.51.5

A-302.1

2.5

KN2 KN2

DOWNSPOUT FROM GUTTER

ABOVE - TYP.

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

279119

A-127.1

SE

C

O N

D F

LO

O

R R

EL

EC

TE

D

C

EI

LI

N

G P

LA

N

- Z O

N E

B

TR

AI

N

IN

G S

U

PP

O R

T

FA

C

IL

IT

Y

AR

M

Y

AV

IA

TI

O N

FO

R

T R

U C

KE

R

, A

LA

BA

M

A M

O

BI

LE

D

IS

TR

IC

T

KN

IG

H T

AR

C

H

IT

EC

TS

, I N

C

P

ER

IM

ET

ER

P

AR

K

D R

IV

E, S U

IT

E

AT

LA

N

TA

G A

JS

W

JS

W

JS

W

JC

K

D

EC

W

8-

-D

-0

W

8F

6F Y1

AS BUILT

1/8" = 1'-0"A-127.1

1 SECOND FLOOR CEILING PLAN - ZONE B

04 8 16268

SCALE: 1/8"=1'-0"

PLAN NORTH

KEY PLAN

ZONE A

ZONE B

ZONE C

NOTE:

REFER TO PLATE A-126.1 FOR KEY NOTES

AND LEGEND.

A

B

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

A

AM

EN

D

. 0

7, R

EP

LA

C

ED

D R

AW

IN

G

JU

N E

B

AS

I N O

. 0

D

EC

1 2 3

A-302.1

F.5

E.5

3.51.5 2 A-302.1

2.5

S3S4

A.F.F.12' - 0" A.F.F.12' - 0"

KN2 KN2

DOWNSPOUT FROM GUTTER

ABOVE - TYP.

GENERAL NOTES

1. DO NOT SCALE DRAWINGS.

2. CENTER CEILING GRIDS IN EACH ROOM AS INDICATED.

3. ALL PENETRATIONS THROUGH CEILING, INCLUDING BUT NOT LIMITED TO MECHANICAL

GRILLES, EXHAUST FANS, LIGHT FIXTURES, AND SPRINKLER HEADS, SHALL BE CENTERED

IN THE CEILING TILE.

4. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.

5. FOR AREAS WHERE NO CEILING FINISH IS INDICATED, THE CEILING IS OPEN TO

STRUCTURE.

6. ALL EXPOSED STRUCTURE SHALL BE PAINTED PNT-6.

7. ALL EXPOSED MECHANICAL AND ELECTRICAL EQUIPMENT AND ASSOCIATED

APPURTENANCES SHALL BE PAINTED PT-1 UNLESS OTHERWISE REQUIRED BY CODE.

8. REFER TO INTERIOR DRAWINGS FOR ADDITIONAL FINISH REQUIREMENTS.

LEGEND

A.F.F.9'-0" CEILING HEIGHT, ABOVE FINISH FLOOR

101 ROOM NUMBER

GYP. BD. CEILING

2 X 4 LIGHT FIXTURE

2 x 2 LIGHT FIXTURE

SUSPENDED STRIP LIGHT

RETURN AIR GRILLE

SUPPLY AIR GRILLE

EXHAUST AIR GRILLE

2' x 2' ACT CEILING

EXIT SIGN

2 X 4 LIGHT FIXTURE W/ EMERGENCY

POWER

SUSPENDED PENDANT FIXTURE

SUSPENDED PENDANT FIXTURE W/

EMERGENCY POWER

SUSPENDED STRIP LIGHT W/

EMERGENCY POWER

WALL MOUNTED FIXTURE W/

EMERGENCY POWER

C1 CEILING TYPE. SEE PLATE A-001.1 FOR

DETAILS

2 x 2 LIGHT FIXTURE W/

EMERGENCY POWER

KEY NOTES

KN1 BULKHEAD - REFER TO DETAIL

4/A-511.1

KN2 EXPOSED DUCTWORK - TYP.

RECESSED COMPACT FIXTURE

EXTERIOR WALL MOUNTED FIXTURE

W/ BATTERY PACK

UNIT HEATER

1-HOUR RATED PARTITION

UNDERSIDE OF METAL DECK

ABOVE - PAINT PNT-6

LED INDUSTRIAL HIGH BAY FIXTURE

W/ EMERCENCY BACKUP

LED INDUSTRIAL HIGH BAY FIXTURE

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

279120

A-128.1

SE

C

O N

D F

LO

O

R R

EF

LE

C

TE

D C

EI

LI

N G

PL

AN

ZO

N E

C

TR

AI

N

IN

G S

U

PP

O R

T

FA

C

IL

IT

Y

AR

M

Y

AV

IA

TI

O N

FO

R

T R

U C

KE

R

, A

LA

BA

M

A M

O

BI

LE

D

IS

TR

IC

T

KN

IG

H T

AR

C

H

IT

EC

TS

, I N

C

P

ER

IM

ET

ER

P

AR

K

D R

IV

E, S U

IT

E

AT

LA

N

TA

G A

JS

W

JS

W

JS

W

JC

K

D

EC

W

8-

-D

-0

W

8F

6F Y1

AS BUILT

1/8" = 1'-0"A-128.1

1 SECOND FLOOR CEILING PLAN - ZONE B

04 8 16268

SCALE: 1/8"=1'-0"

PLAN NORTH

KEY PLAN

ZONE A

ZONE B

ZONE C

A

B

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

A

AM

EN

D

. 0

7, R

EP

LA

C

ED

D R

AW

IN

G

JU

N E

B

AS

I N O

. 0

D

EC