W912BV21R0004_AM0003.pdf
PDF 766 KB Posted
- Attached to
- AIT Complex, Phase 2, Dining Facility, Fort Sill, Oklahoma Federal contract opportunity
- Solicitation number
- W912BV21R0004
About this file
This amendment modifies a solicitation for the construction of an Advanced Individual Training Barracks Dining Facility at Fort Sill, Oklahoma. The amendment removes previously issued drawings IN205, IN207, and S-510 and replaces them in their entirety with revised versions. It also updates references in drawing IN207 from sheet IN208 to the correct sheet IN207. The revisions include changes to wall elevations, tile patterns, and concrete details. Offerors are instructed to replace the specified sheets in the solicitation with the revised versions attached to the amendment.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W912BV21R0004_AM0007.pdf | ||
| W912BV21R0004_AM0006.pdf | ||
| W912BV21R0004_AM0005_Compiled.pdf | ||
| W912BV21R0004_AM0004.pdf | ||
| AM0002 - Sheet - IN601 - MATERIALS FINISH LEGEND.pdf | ||
| Fort Sill Installation Design Standard.pdf | ||
| AM0002 - Section 01 11 00 - Paragraph 1.3 Redacted.pdf | ||
| W912BV21R0004_AM0002.pdf | ||
| AM0002 - Sheet - G-001 - COVER SHEET.pdf | ||
| DFAC Site Visit Location.jpg | JPG image | |
| W912BV21R0004_AM0001.pdf | ||
| _Ft Sill DFAC - Specifications_Final.pdf | ||
| Ft Sill DFAC - PLANS - VOL 1.pdf | ||
| Ft Sill DFAC - PLANS - VOL 3_Part4.pdf | ||
| Ft Sill DFAC - PLANS - VOL 3_Part1.pdf | ||
| Ft Sill DFAC - PLANS - VOL 3_Part7.pdf | ||
| Ft Sill DFAC - PLANS - VOL 3_Part3.pdf | ||
| Ft Sill DFAC - PLANS - VOL 3_Part6.pdf | ||
| Ft Sill DFAC - PLANS - VOL 2.pdf | ||
| Ft Sill DFAC - PLANS - VOL 3_Part5.pdf | ||
| Ft Sill DFAC - PLANS - VOL 3_Part2.pdf |
Show all 21
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
This Amendment is to remove previously issued draw ings IN205, IN207, S-510 in their entirety and replace w ith IN205, IN207, and S-510 hereto.
The POC for this Amendment is the Contract Specialist: Tyler Godw in; tyler.l.godw in@usace.army.mil, 918-669-7281
1. CONTRACT ID CODE PAGE OF PAGES
1 2
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 29-Apr-2022
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X W912BV21R0004
X 9B. DATED (SEE ITEM 11)
24-Mar-2022
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
29-Apr-2022
CODE
CONTRACTING DIV
US ARMY CORPS OF ENGINEERS, TULSA DISTRICT
2488 E. 81ST STREET
TULSA OK 74137-4290
W912BV 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
i
AMENDMENT 0003
W912BV21R0004
AIT Complex, Phase 2, Dining Facility (DFAC) Fort Sill, Oklahoma
The revised/new sections/appendices/pages listed below are hereby added to or revised and made a part of the solicitation. Revised or added/deleted information can be located in the specifications by searching for an asterisk and amendment number (i.e., *AM and *). The beginning of the amendment will begin with *AM and end with an * for each amended section. Changes are shown with green text for additions and red text for deletion.
REVISED SPECIFICATION SECTIONS
Remove previously issued specification section Table of Contents and replace in their entirety with new specification section Table of Contents.
ADDED NEW SPECIFICATION SECTIONS
N/A
ADDED NEW DRAWING SHEETS
N/A
REVISED DRAWINGS
Remove previously issued drawings IN205, IN207, S‐510 in their entirety and replace with IN205, IN207, and S‐510 hereto.
A summary of the changes made to these drawings includes, but is not limited to:
IN205: Details A1 and D1 ‐ Revise dimension string reference sheet annotation from IN208 to IN207.
IN207: Detail A1 ‐ Revise dimension string reference sheet annotation from IN208 to IN207. Detail C1 change detail title from Typical Serving Wall Tile Pattern to Typical Wall Tile Pattern.
S‐510: Revise Detail annotation from A1 to C8.
Revised Page(s) to Project Drawings. Revised page(s) replace the like‐numbered page(s) in the subject solicitation drawings. Changes are indicated by a revision cloud on the sheet. All portions of the revised page(s) shall apply whether or not changes have been indicated.
End of Continuation Sheet
DEPARTMENT OF THE ARMY
Kansas City District, Corps of Engineers
647 Federal Building Kansas City, Missouri 64106
SPECIFICATIONS FOR CONSTRUCTION OF
AIT COMPLEX PHASE II DFAC
FORT SILL, OKLAHOMA
*TABLE OF CONTENTS *AM3
Volume 1 of 3
DIVISION 00 PROCUREMENT AND CONTRACTING REQUIREMENTS
*00 11 00 PRICING (CLIN) SCHEDULE *AM1
*00 21 00 INSTRUCTIONS *AM1
*00 22 11 EVALUATION CRITERIA, BASIS OF AWARD *AM1, *AM2
00 45 00 REPRESENTATIONS AND CERTIFICATIONS
00 72 00 GENERAL CONDITIONS
00 73 00 SUPPLEMENTARY CONDITIONS
01 00 00 GENERAL REQUIREMENTS
DIVISION 01 – GENERAL REQUIREMENTS
01 04 00 COORDINATION, FIELD ENGINEERING, AND MEETINGS (FSAO)
*01 11 00 SUMMARY OF WORK *AM2
01 30 00 ADMINISTRATIVE REQUIREMENTS
01 30 01 ADDITIONAL ADMINISTRATIVE REQUIREMENTS
01 32 01.00 10 PROJECT SCHEDULE FULL DBB
01 33 00.15 DIGITAL SUBMITTAL PROCEDURES & CORRESPONDENCE
01 33 29 SUSTAINABILITY REPORTING
01 35 26.10 10 GOVERNMENTAL SAFETY REQUIREMENTS - FSAO
01 42 00 SOURCES FOR REFERENCE PUBLICATIONS
01 45 00.00 15 QUALITY CONTROL (DBB)
01 45 00.15 10 RESIDENT MANAGEMENT SYSTEM CONTRACTOR MODE (RMS 3.0 CM)
01 45 35 SPECIAL INSPECTIONS
01 50 00 TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS
01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS
01 57 20.10 10 ENVIRONMENTAL PROTECTION – FSAO
01 58 00 BULLETIN BOARD, PROJECT SIGN, AND SAFETY SIGN
01 74 19 CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT
01 78 00.00 15 CLOSEOUT SUBMITTALS
01 78 23.10 10 OPERATION AND MAINTENANCE DATA - FSAO
01 91 00.15 TOTAL BUILDING COMMISSIONING
01 91 00.16 MECHANICAL/BUILDING CONTROL SYSTEMS INTEGRATOR
DIVISION 02 – EXISTING CONDITIONS
02 41 00 DEMOLITION
DIVISION 03 – GENERAL REQUIREMENTS
03 30 00 CAST-IN-PLACE CONCRETE
DIVISION 04 – MASONRY
04 20 00 UNIT MASONRY
DIVISION 05 – METALS
05 05 20.00 27 POST-INSTALLED CONCRETE AND MASONRY ANCHORS
05 12 00 STRUCTURAL STEEL
05 21 00 STEEL JOIST FRAMING
05 30 00 STEEL DECKS
05 40 00 COLD-FORMED METAL FRAMING
05 50 13 MISCELLANEOUS METAL FABRICATIONS
05 51 33 METAL LADDERS
DIVISION 06 – WOOD, PLASTICS, AND COMPOSITES
06 10 00 ROUGH CARPENTRY
06 20 00 FINISH CARPENTRY
06 61 16 SOLID SURFACING FABRICATIONS
DIVISION 07 – THERMAL AND MOISTURE PROTECTION
07 05 23 PRESSURE TESTING AN AIR BARRIER SYSTEM FOR AIR
TIGHTNESS
07 11 13 BITUMINOUS DAMPPROOFING
07 21 13 BOARD AND BLOCK INSULATION
07 21 16 MINERAL FIBER BLANKET INSULATION
07 24 00 EXTERIOR INSULATION AND FINISH SYSTEMS
07 27 10.00 10 BUILDING AIR BARRIER SYSTEM
07 27 19.01 SELF-ADHERING AIR BARRIERS
07 27 26 FLUID-APPLIED MEMBRANE AIR BARRIERS
07 27 36 SPRAY FOAM AIR BARRIERS
07 41 13 METAL ROOF PANELS
07 60 00 FLASHING AND SHEET METAL
07 84 00 FIRESTOPPING
07 92 00 JOINT SEALANTS
DIVISION 08 – OPENINGS
08 11 13 STEEL DOORS AND FRAMES
08 22 20 FIBERGLASS REINFORCED PLASTIC (FRP) DOORS AND FRAMES
08 33 23 OVERHEAD COILING DOORS
08 36 13 SECTIONAL OVERHEAD DOORS
08 41 13 ALUMINUM-FRAMED ENTRANCE AND STOREFRONTS
08 51 13 ALUMINUM WINDOWS
08 71 00 DOOR HARDWARE
08 81 00 GLAZING
08 91 00 METAL WALL LOUVERS
DIVISION 09 – FINISHES
09 22 00 SUPPORTS FOR PLASTER AND GYPSUM BOARD
09 29 00 GYPSUM BOARD
09 30 10 CERAMIC, QUARRY, AND GLASS TILING
09 51 00 ACOUSTICAL CEILINGS
09 65 00 RESILIENT FLOORING
09 67 23.13 STANDARD RESINOUS FLOORING
09 90 00 PAINT AND COATINGS
09 96 00 HIGH-PERFORMANCE COATINGS
DIVISION 10 – SPECIALTIES
10 11 00 VISUAL DISPLAY UNITS
10 14 00.20 INTERIOR SIGNAGE
10 21 13 TOILET COMPARTMENTS
10 26 00 WALL AND DOOR PROTECTION
10 28 13 TOILET ACCESSORIES
10 44 16 FIRE EXTINGUISHERS
10 51 13 METAL LOCKERS
Volume 2 of 3
DIVISION 11 – EQUIPMENT
11 05 40 COMMON WORK RESULTS FOR FOODSERVICE EQUIPMENT
11 06 40.13 FOODSERVICE EQUIPMENT SCHEDULE
11 13 19.13 LOADING DOCK LEVELERS
11 42 00 FOOD PREPARATION EQUIPMENT
11 46 00 FOOD DISPENSING EQUIPMENT
11 47 00 ICE MACHINES
11 48 00 CLEANING AND DISPOSAL EQUIPMENT
DIVISION 12 – FURNISHINGS
12 21 00 WINDOW BLINDS
12 48 13 ENTRANCE FLOOR MATS AND FRAMES
DIVISION 13 – SPECIAL CONSTRUCTION
13 48 00 SEISMIC AND AT/FP BRACING FOR MISCELLANEOUS COMPONENTS AND
SYSTEMS
DIVISION 21 – FIRE SUPPRESSION
21 13 13.00 10 WET PIPE SPRINKLER SYSTEM, FIRE PROTECTION
DIVISION 22 – PLUMBING, GENERAL PURPOSE
22 00 00 PLUMBING, GENERAL PURPOSE
DIVISION 23 – HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)
23 00 00 AIR SUPPLY, DISTRIBUTION, VENTILATION, AND EXHAUST
23 05 15 COMMON PIPING FOR HVAC
23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC
23 07 00 THERMAL INSULATION FOR MECHANICAL SYSTEMS
23 09 00 INSTRUMENTATION AND CONTROL FOR HVAC
23 09 13 INSTRUMENTATION AND CONTROL DEVICES FOR HVAC
23 09 23.02 BACNET DIRECT DIGITAL CONTROL FOR HVAC AND OTHER
BUILDING CONTROL SYSTEMS
23 11 25 FACILITY GAS PIPING
23 21 23 HYDRONIC PUMPS
23 52 00 HEATING BOILERS
23 64 10 WATER CHILLERS, VAPOR COMPRESSION TYPE
23 64 26 CHILLED, CHILLED-HOT, AND CONDENSER WATER PIPING
23 81 00 DECENTRALIZED UNITARY HVAC EQUIPMENT
DIVISION 25 – INTEGRATED AUTOMATION
25 05 11.10 CYBERSECURITY FOR FACILITY-RELATED CONTROL SYSTEMS
– BACNET DIRECT DIGITAL CONTROL FOR HVAC & OTHER
BUILDING CONTROL SYSTEMS
25 05 11.11 CYBERSECURITY FOR FACILITY-RELATED CONTROL SYSTEMS
– FIRE DETECTION AND ALARM SYSTEM
25 05 11.12 CYBERSECURITY FOR FACILITY-RELATED CONTROL SYSTEMS
– LIGHTING CONTROLS & OTHER SYSTEMS
25 08 10 UTILITY MONITORING AND CONTROL SYSTEM TESTING
25 10 10 UTILITY MONITORING AND CONTROL SYSTEM (UMCS) FRONT
END AND INTEGRATION
DIVISION 26 – ELECTRICAL
26 05 48.00 10 SEISMIC PROTECTION FOR ELECTRICAL EQUIPMENT
26 08 00 APPARATUS INSPECTION AND TESTING
26 12 19.10 THREE-PHASE PAD-MOUNTED TRANSFORMERS
26 13 01 PAD-MOUNTED DEAD-FRONT AIR INSULATED SWITCHGEAR
26 20 00 INTERIOR DISTRIBUTION SYSTEM
26 24 13 SWITCHBOARDS
26 28 01.00 10 COORDINATED POWER SYSTEM PROTECTION
26 29 23 ADJUSTABLE SPEED DRIVE (ASD) SYSTEMS UNDER 600 VOLTS
26 41 00 LIGHTNING PROTECTION SYSTEM
26 42 14.00 10 CATHODIC PROTECTION SYSTEM (SACRIFICIAL ANODE)
26 51 00 INTERIOR LIGHTING
26 56 00 EXTERIOR LIGHTING
Volume 3 of 3
DIVISION 27 – COMMUNICATIONS
27 10 00 BUILDING TELECOMMUNICATIONS CABLING SYSTEM
27 51 16 PUBLIC ADDRESS SYSTEM
DIVISION 28 – ELECTRONIC SAFETY AND SECURITY
28 31 76 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM,
ADDRESSABLE
DIVISION 31 – EARTHWORK
31 00 00 EARTHWORK
31 11 00 CLEARING AND GRUBBING
31 32 23 FOUNDATION DRILLING AND GROUTING
31 62 23.13 CAST-IN-PLACE CONCRETE PILES, STEEL CASING
31 63 26 DRILLED CASSIONS
DIVISION 32 – EXTERIOR IMPROVEMENTS
32 05 33 LANDSCAPE ESTABLISHMENT
32 11 13.13 LIME TREATED SUBGRADE
32 11 23 AGGREGATE BASE COURSES
32 11 29 LIME-STABLIZED SUBGRADE
32 13 13.06 PORTLAND CEMENT CONCRETE PAVEMENT FOR ROADS & SITE
FACILITIES
32 16 19 CONCRETE CURBS, GUTTERS AND SIDEWALKS
32 17 23 PAVEMENT MARKINGS
32 92 23 SODDING
32 93 00 EXTERIOR PLANTS
DIVISION 33 – UTILITIES
33 11 00 WATER UTILITY DISTRIBUTION PIPING
33 30 00 SANITARY SEWERAGE
33 40 00 33 51 15
STORM DRAINAGE UTILITIES
NATURAL-GAS / LIQUEFIED PETROLEUM GAS
DISTRIBUTION PIPELINES
33 71 01 OVERHEAD TRANSMISSION AND DISTRIBUTION
33 71 02 UNDERGROUND ELECTRICAL DISTRIBUTION
*ATTACHMENTS
Fort Sill Installation Design Standard *AM2
- END OF TABLE OF CONTENTS - *AM3
WALL PAINT
(PT-1)
PRE-FABRICATED
LAVATORY (SSM-4);
RE : SPEC 22 00 00
WALL PAINT
(PT-1)
PTD
SD
HEAD COUNT
STATION. REF:
IN401 & IN503
TYP.
TYP.
WB WB WB
REF: SHEET IN207 FOR TYPICAL TILE PATTERN
13' - 10"
R E
F : S
H E
E T
IN
F
O R
T Y
P
IC
A L
T
IL
E P
A T
T E
R N
6'
PORCELAIN BASE
TILE (PBT-1)
(TYPICAL 12" X 6")
0' - 11 1/4" 2' - 3" 1' - 2" 2' - 2" 2' - 2" 1' - 2" 2' - 3" 1' - 9"
WALL PAINT
(PT-2)
PRE-FABRICATED
LAVATORY (SSM-4);
REF SPEC: 22 00 00
PORCELAIN WALL
TILE (PWT-1)
WALL PAINT (PT-1)
PTD
SD
TYP.
TYP.
HEAD COUNT STATION
REF: IN401 & IN503
WB WB WB
R E
F : S
H E
E T
IN
F
O R
T Y
P
IC
A L
T
IL
E P
A T
T E
R N
6'
REF: SHEET IN207 FOR TYPICAL TYLE PATTERN
13' - 9 3/4"
0' - 11 1/4"2' - 3"1' - 2"2' - 2"2' - 2"1' - 2"2' - 3"1' - 8 3/4"
1. UNLESS OTHERWISE NOTED, VERTICAL DIMENSIONS ARE TAKEN FROM
FINISH FLOOR.
GENERAL SHEET NOTES
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
US Army Corps of Engineers
S O
LI
C
IT
A
T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T
E D
B Y
D A
T E
C O
N T
R A
C T
N O
C
H E
C K
E D
B Y
D R
A W
N B
Y
IS
S
U E
D A
T E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
Plot Date: 4/26/2022 1:39:36 PM
IN205
IN
T
E R
IO
R
E
LE
V A
T
IO
N S
F T
S
IL
L, O
K
LA
H O
M A
K A
N S
A S
C
IT
Y D
IS
T
R
IC
T
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
W . F
O R
D
W . F
O R
D
C . B
R O
W N
C . G
A T
E W
O O
D
F E
B R
U A
R Y
F
IL
E N
A M
E
BCOES
D
IN
IN
G
F A
C
IL
IT
Y
D
F A
C
F O
R A
IT
B
A R
R A
C K
S P
N
3, P
P N
3_ F
T S
-A
IT
II-
D
F A
C _R
V T
_A
I
E . 1
2T H
S T
R E
E T
K A
N S
A S
C
IT
Y , M
O
T U
LS
A
D
IS
T R
IC
T
S
E
A V
E T
U
LS
A , O
K
-4
A
N S
I D
1/2" = 1'-0"A1 HEAD COUNT & HAND WASH STATION - TYPICAL SOUTH WALL ELEVATION
1/2" = 1'-0"D1 HEAD COUNT & HAND WASH STATION - TYPICAL NORTH WALL ELEVATION
2'1' 4'0
2'1' 4'0
TOILET ACCESSORIES LEGEND
CODE DESCRIPTION
BN FLOOR MOUNTED BENCH
FSS FOLDING SHOWER SEAT
FWM FRAMED WALL MIRROR
GB18 18" GRAB BAR
GB36 36" GRAB BAR
GB42 42" GRAB BAR
GB-S SHOWER GRAB BARS
PTD PAPER TOWEL DISPENSER
RH SURFACE MOUNTED ROBE HOOK
RH-B SURFACE MOUNTED ROBE HOOK - BARRIER FREE
SC/SCR SHOWER CURTAIN / SHOWER CURTAIN ROD
SD SOAP DISPENSER
SND SANITARY NAPKIN DISPOSAL
TTD TOILET TISSUE DISPENSER
WB WASTE BASKET
A
M
C H
A N
G E
D
IN
R E
F E
R E
N C
E S
T O
IN
/2 6/
FOR SERVICE ACCESS
6" SIDE CLEARANCE
WALL PAINT
(PT-1)
RUBBER BASE
(RB-1)
DOOR FRAME
(PT-5)
REF: SHEET IN207 FOR TYPICAL TILE PATTERN
21' - 9 3/4"
R E
F : S
H E
E T
IN
F
O R
T Y
P
IC
A L
T
IL
E P
A T
T E
R N
7'
PORCELAIN BASE
TILE (PBT-1) ON GYP
SURFACES; WALLS WITH
CMU COVE BASE SHALL
RECIEVE NO BASE TILE
PORCELAIN WALL
TILE (PWT-3)
(TYPICAL)
PORCELAIN WALL
TILE (PWT-2)
(TYPICAL)
PORCELAIN WALL
TILE (PWT-1)
(TYPICAL)
PATTERN REPEAT
7' - 0"
1'
P A
T T
E R
N R
E P
E A
T
1. UNLESS OTHERWISE NOTED, VERTICAL DIMENSIONS ARE TAKEN FROM
FINISH FLOOR.
GENERAL SHEET NOTES
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
US Army Corps of Engineers
S O
LI
C
IT
A
T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T
E D
B Y
D A
T E
C O
N T
R A
C T
N O
C
H E
C K
E D
B Y
D R
A W
N B
Y
IS
S
U E
D A
T E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
Plot Date: 4/26/2022 1:39:49 PM
IN207
IN
T
E R
IO
R
E
LE
V A
T
IO
N S
F T
S
IL
L, O
K
LA
H O
M A
K A
N S
A S
C
IT
Y D
IS
T
R
IC
T
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
W . F
O R
D
W . F
O R
D
C . B
R O
W N
C . G
A T
E W
O O
D
F E
B R
U A
R Y
F
IL
E N
A M
E
BCOES
D
IN
IN
G
F A
C
IL
IT
Y
D
F A
C
F O
R A
IT
B
A R
R A
C K
S P
N
3, P
P N
3_ F
T S
-A
IT
II-
D
F A
C _R
V T
_A
I
E . 1
2T H
S T
R E
E T
K A
N S
A S
C
IT
Y , M
O
T U
LS
A
D
IS
T R
IC
T
S
E
A V
E T
U
LS
A , O
K
-4
A
N S
I D
1/2" = 1'-0"A1 SODA FOUNTAIN WALL ELEVATION
1/2" = 1'-0"C1 TYPICAL WALL TILE PATTERN
2'1' 4'0
2'1' 4'0
A
M 0 0
C H
A N
G E
D
IN
R E
F E
R E
N C
E S
T O
IN
/2 6/
#4 @ 12" OC EW
3/4" CHAMFER
4"
FOR EXACT EQUIPMENT SIZES AND LOCATIONS
SIZE FOR 6" CLEAR ALL AROUND EQUIPMENT -
COORDINATE WITH MECHANICAL & ELECTRICAL CONTRACTORS
CAULK, TYP
NOTES:
1. ANCHOR EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS.
2. DOWELS MAY BE DRILLED AND EPOXIED W/ APPROVED ADHESIVE ANCHORING
SYSTEM USING OVERSIZE HOLES. CLEAN AND PREPARE HOLES PER EPOXY MFR.
DOWEL EMBEDMENT SHALL BE 4".
3. SEE MECHANICAL AND ELECTRICAL SHEETS FOR LOCATION OF EQUIPMENT PADS.
EQUIPMENT
SIZE FOR 12" CLEAR ALL AROUND EQUIPMENT
6"
1'
8" #5 CONT, TYP
#4 @ 12" EW FOR
6" CONCRETE SLAB
REFER TO CIVIL
DRAWINGS
FOR SUBBASE
PREPARATION
FINISHED GRADE
RE: CIVIL
CHAMFER
EDGE
ROUGHEN CONSTRUCTION JOINT
KEYED CONSTRUCTION JOINT
S
LA
B T
H
IC
K N
E S
S
T
S
LA
B T
H
IC
K N
E S
S
T
ROUGHEN SURFACE
CONTINUE REINF THROUGH
CONSTRUCTION JOINT
E Q
E Q
E
Q CONT KEYWAY
1 1/2" WIDE
LAP
PROPERLY PREPARED
NATIVE SOILS OR FILL
10 MIL VAPOR BARRIER, UNO
REBAR REINF - REFER TO
FOUNDATION PLAN
STRUCTURAL SLAB. REFER TO
FOUNDATION PLAN
6" CARTON FORM, SEE SPEC 03 30 00
TYP
0' - 2"0' - 4"
CONCRETE
BEAM CONTINUOUS BEAM
REINFORCING THROUGH JOINT
ROUGHEN SURFACE
TO 1/4" AMPLITUDE
LOCATE WITHIN
MIDDLE 1/3 OF SPAN
ADDITIONAL #4 STIRRUPS,
EACH SIDE OF JOINT, TYP
NOTES:
1. WAIT MINIMUM OF 7 DAYS BETWEEN ADJACENT CONCRETE
POURS. CONTRACTOR SHALL SUBMIT POUR SEQUENCE FOR
APPROVAL PRIOR TO CONCRETE PLACEMENT.
2. REINF SHALL BE CONTINUOUS THROUGH JOINT.
3. ALL LAITANCE ON HARDENED CONCRETE TO BE REMOVED AND
SURFACE TO BE CLEANED AND WETTED IMMEDIATELY PRIOR TO
POURING FRESH CONCRETE.
GRADE BEAM
STANDARD
HOOK
LAP SPLICE +6"
STANDARD
HOOK
STIRRUPS, TYP
GRADE BEAM
STIRRUPS, TYP
M A
X T
Y P
M A
X T
Y P
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
US Army Corps of Engineers
S O
LI
C
IT
A
T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T
E D
B Y
D A
T E
C O
N T
R A
C T
N O
C
H E
C K
E D
B Y
D R
A W
N B
Y
IS
S
U E
D A
T E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
Plot Date: 4/25/2022 8:32:32 AM
S-510
T Y
P
IC
A L
C O
N C
R E
T E
D E
T A
IL
S
F O
R T
S
IL
L, O
K
LA
H O
M A
K A
N S
A S
C
IT
Y D
IS
T
R
IC
T
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
L.
S
C H
U S
T E
R
L.
S
C H
U S
T E
R
A . S
V
IT
A K
J.
B
U S
H
IE
S E
P T
E M
B E
R
S E
E C
O V
E R
P A
G E
S E
E C
O V
E R
P A
G E
F
IL
E N
A M
E
BCOES
A
IT
C O
M P
LE
X
P H
A S
E
II
D
F A
C P
N
3, P
P N
3_ F
T S
-A
IT
II-
D
F A
C _R
V T
_S
E . 1
2T H
S T
R E
E T
K A
N S
A S
C
IT
Y , M
O
T U
LS
A
D
IS
T R
IC
T
S
E
A V
E T
U
LS
A , O
K
-4
A
N S
I D
NTSE1 TYPICAL INTERIOR EQUIP PAD
NTSE4
TYPICAL EXTERIOR
EQUIPMENT PAD
NTSC4
SLAB CONSTRUCTION JOINT
NTSC8 TYPICAL STRUCTURAL SLAB DETAIL
NTSC1 TYPICAL BEAM CONSTRUCTION JOINT
3/4" = 1'-0"E8
TYPICAL GRADE BEAM INTERSECTION
DETAIL
A
M
U P
D A
T E
D D
E T
A
IL
C
| W912BV21R0004_AM0003.pdf |
| W912BV21R0004_AM0003 DRAFT compiled.pdf |
| _AM3 CONT SHEET |
| AM0003 - Compiled Sheets |
| Sheets |
| IN205 - INTERIOR ELEVATIONS |
| IN207 - INTERIOR ELEVATIONS |
| AM0003 - Sheet - S-510 - TYPICAL CONCRETE DETAILS.pdf |
| Sheets |
| S-510 - TYPICAL CONCRETE DETAILS |
| AM0003 - Sheet - IN207 - INTERIOR ELEVATIONS.pdf |
| Sheets |
| IN205 - INTERIOR ELEVATIONS |
| IN207 - INTERIOR ELEVATIONS |
File details come from the government source that posted it. Updated .