FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_drawings_Part6.pdf

PDF 9 MB Posted

Attached to
$300M Small Business DBB MATOC
Solicitation number
W9128A-19-R-0002
Issued by

About this file

This document provides details for a $300 million Multiple Award Task Order Contract (MATOC) opportunity with the U.S. Army Corps of Engineers Engineering District Honolulu. Small businesses will be able to compete for design-bid-build construction services contracts in the state of Hawaii on a task order basis. The last day for offerors to submit requests for information is September 16, 2019. The MATOC aims to streamline the award of smaller construction projects in Hawaii to small businesses.

Sample Project - Drawing 6 of 12

View the file

Other files

File Type Posted
sf30-19r2-am6.pdf PDF
sf30-19r2-am5.pdf PDF
sf30-19r2-am4.pdf PDF
19r2-sf30-am3.pdf PDF
sf30-19r2-am2.pdf PDF
sf30-19r2-am1.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_drawings_Part11.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_drawings_Part10.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_drawings_Part9_Part3.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_drawings_Part9_Part2.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_drawings_Part8.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_specifications_Part6.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_specifications_Part7.pdf PDF
A.2.11.3_19r2-rfp.pdf PDF
POHMATOC_-_Specifications_6_June_2019.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_drawings_Part7.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_specifications_Part1.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_drawings_Part1.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_specifications_Part9-1.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_specifications_Part8.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_specifications_Part10.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_specifications_Part11.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_drawings_Part2.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_drawings_Part12.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_drawings_Part3.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_specifications_Part4.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_drawings_Part9_Part1.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_specifications_Part2.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_drawings_Part4.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_specifications_Part5.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_specifications_Part3.pdf PDF
FY17_Rpr_by_Rpl_Var_Bldgs_Block_A1_drawings_Part5.pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CG502

V O

LU

M

E

G E

N E

R A

L N

O

TE

S

1. THIS PROTOCOL IS INTENDED TO PROVIDE FOR THE OPTIONAL

USE OF OFF-SITE PTA �UARRIED MATERIAL UNDER

CONDITIONS OF IMMEDIATE AND EXIGENT NEED, BASED ON

CONSIDERATIONS FOR PROJECT SCHEDULES, COSTS, AND THE

AVAILABILITY OF AGGREGATE FROM THE ON-SITE MAIN

�UARRY AT PTA. INCREASED RISK OF IMPORTATION OF

INVASIVE PLANT AND INVERTEBRATE SPECIES TO PTA/KMA

THROUGH THE USE OF OFF-SITE �UARRY MATERIAL IS

UNAVOIDABLE, AND ALTHOUGH THIS PROTOCOL IS DESIGNED

TO REDUCE RISK TO A MINIMUM LEVEL, RISK CANNOT BE

ELIMINATED. THEREFORE, RE�UESTS FOR THE OPTIONAL USE

OF OFF-SITE �UARRY MATERIAL SHALL BE CONSIDERED ONLY

FOR EXCEPTIONAL CIRCUMSTANCES, AND WITH THE ONUS OF

JUSTIFICATION ON THE PROJECT PROPONENT. JUSTIFICATION

OF NEED WILL NOT NECESSARILY LEAD TO AN APPROVAL FOR

USE OF OFF-SITE AGGREGATE. CONDITIONS AT THE OFF-SITE

�UARRY OR OTHER SOURCE, WITH RESPECT TO PRESENCE

AND TYPES OF INVASIVE SPECIES, AND ASSESSED RISKS FOR

IMPORTATION OF INVASIVE SPECIES TO PTA/KMA, SHALL BE

THE FINAL DETERMINING FACTORS.

2. THE PROJECT PROPONENT SHALL SUBMIT A DETAILED RE�UEST

FOR THE USE OF OFF-SITE AGGREGATE TO THE ARMY BIOLOGIST

AT THE PTA NATURAL RESOURCES OFFICE AT LEAST 60 DAYS

PRIOR TO PROPOSED DELIVERY OF MATERIAL TO THE PTA/KMA

CONSTRUCTION SITE. INFORMATION PROVIDED SHALL INCLUDE

BUT NOT NECESSARILY BE LIMITED TO:

DESCRIPTION OF NEGATIVE IMPACTS ON PROJECT

SCHEDULE/COSTS DUE TO USE OF ON-SITE PTA

�UARRY MATERIAL�

LOCATION OF OFF-SITE AGGREGATE SOURCE, AND

CONTACT INFORMATION OF �UARRY OPERATOR�

PROJECT LOCATION AT PTA/KMA�

DISTRIBUTION OF EXISTING INVASIVE SPECIES AT THE

PTA/KMA PROJECT LOCATION�

�UANTITY, TYPE, AND SIZE GRADATION OF OFF-SITE

AGGREGATE�

DESCRIPTION OF THE USE AND DISTRIBUTION OF

OFF-SITE AGGREGATE AT THE PTA/KMA PROJECT SITE�

PROPOSED DELIVERY SCHEDULE FOR OFF-SITE

AGGREGATE�

SCHEDULED PROJECT COMPLETION DATE.

3. IF JUSTIFICATION FOR OPTIONAL USE OF OFF-SITE AGGREGATE IS

ACCEPTED BY THE ARMY BIOLOGIST, A NATURAL RESOURCES

OFFICE BIOLOGIST SHALL CONDUCT A SITE INSPECTION AT THE

PROPOSED OFF-SITE �UARRY OR OTHER SOURCE, TO

DETERMINE THE PRESENCE OF INVASIVE PLANT AND

INVERTEBRATE SPECIES, AND TO EVALUATE THE RISK OF

IMPORTATION OF SPECIES TO PTA, IF INVASIVE SPECIES ARE

PRESENT.

4. INSPECTION PROCEDURES:

4.1. PLANTS: SELECTED AGGREGATE STOCKPILES AT THE

OFF-SITE LOCATION SHALL BE VISUALLY INSPECTED IN THEIR

ENTIRETY FOR THE PRESENCE OF PLANTS, PLANT PARTS, OR

SEEDS, TO THE EXTENT PRACTICAL VIA SURFICIAL SURVEY. IF

PRESENT, PLANT MATTER MUST BE IDENTIFIED TO THE

LOWEST TAXON POSSIBLE AND DOCUMENTED FOR

REPORTING PURPOSES. AREAS ADJACENT TO THE

STOCKPILE SHALL BE INSPECTED TO A DISTANCE OF 100 M

FROM THE STOCKPILE BASE, WITH PARTICULAR ATTENTION

GIVEN TO WINDWARD AREAS. POINTS AND AREAS OF

CONCERN WITHIN STOCKPILE AND FOR ADJACENT AREAS

WILL BE GEO-LOCATED. IF SURVEYS INDICATE THE PRESENCE

OF INVASIVE PLANTS OR PLANT PARTS, MANAGEMENT

MEASURES IN ACCORDANCE WITH 8.1 BELOW WILL BE

IMPLEMENTED IN PLACE PRIOR TO REMOVAL OF AGGREGATE

FROM �UARRY STOCKPILE.

4.2. INSPECTION FOR INVERTEBRATES (ANTS) WILL BE

CONDUCTED AT THE SELECTED SOURCE STOCKPILE, AT TEN

(10) E�UALLY SPACED PERIMETER LOCATIONS BETWEEN THE

STOCKPILE BASE AND ELEVATION 5 M ABOVE EXISTING

GRADE. INSPECTION WILL BE CONDUCTED USING THE "ANT

CARD" METHOD, AS DEVELOPED BY HARTLEY AND LESTER

(HARTLEY, S., LESTER, P.J. 2005. NATIONAL ANT

SURVEILLANCE SENSITIVITY TRIAL: FINAL REPORT.

TECHNICAL REPORT TO NEW ZEALAND MINISTRY OF

AGRICULTURE AND FORESTRY, CONTRACT NO. BER 64/2003).

ALL ANT SPECIES FOUND WILL BE CONSIDERED INVASIVE, SO

TAXONOMIC IDENTIFICATION IS NOT RE�UIRED. IF ANT CARDS

INDICATE THE PRESENCE OF ANTS, MANAGEMENT MEASURES

IN ACCORDANCE WITH 8.2 BELOW WILL BE IMPLEMENTED IN

PLACE PRIOR TO REMOVAL OF AGGREGATE FROM �UARRY

STOCKPILE.

5. ASSESSMENT OF RISK

5.1. GENERAL:

5.1.1. OFF-SITE AGGREGATE MATERIAL WILL BE LIMITED TO

�UARRIED SUB-SURFACE ROCK MATERIAL ONLY, AND

WILL NOT INCLUDE SOIL MATERIAL. ALL OFF-SITE

�UARRIED MATERIAL USED AT PTA/KMA WILL BE

SOURCED EXCLUSIVELY FROM HAWAII ISLAND. BECAUSE

OF THE NATURE OF �UARRIED ROCK (I.E. DEVOID OF

SOIL OVERBURDEN) IT IS UNLIKELY THAT �UARRIED

MATERIAL FROM OFF-SITE WOULD BE A SOURCE OF

INVASIVE PLANTS, PLANT PARTS, SEEDS, OR

INVERTEBRATE SPECIES. MOREOVER, THE USE OF

�UARRIED FILL MATERIAL IN ENGINEERED

CONSTRUCTION FOR ROAD BEDS, TRENCH BACKFILL,

CONCRETE, ETC., DOES NOT PROVIDE A FAVORABLE

ENVIRONMENT FOR THE GROWTH OR PROPAGATION OF

LIVING MATTER. THESE INHERENT CHARACTERISTICS OF

CONDITIONS AT �UARRIES, AND THE END-USE OF

OFF-SITE AGGREGATE PRODUCTS AT PTA/KMA, GREATLY

REDUCE THE PROBABILITY THAT INVASIVE SPECIES WILL

BE INTRODUCED TO PTA/KMA THROUGH THE USE OF

OFF-SITE �UARRIED MATERIAL.

5.2. SPECIFIC:

5.2.1. SPECIFIC RISKS SHALL BE ASSESSED BASED ON PLANT

OR INVERTEBRATE SPECIES IDENTIFIED PER 4.1 AND 4.2

ABOVE. ASSESSMENT OF SPECIFIC RISKS SHALL

ACCOUNT FOR:

TYPES AND NUMBERS OF PLANT/INVERTEBRATE

SPECIES FOUND AT THE OFF-SITE �UARRY�

CURRENT DISTRIBUTION OF THESE SPECIES ACROSS

PTA/KMA�

PROJECT LOCATION AT PTA/KMA

�UANTITY OF OFF-SITE MATERIAL TO BE TRANSPORTED

TO PTA/KMA

END-USE OF OFF-SITE MATERIAL AT PTA/KMA

6. WITHIN 2 WEEKS FOLLOWING THE FIELD INSPECTION AT THE

OFF-SITE �UARRY, THE NATURAL RESOURCES OFFICE BIOLOGIST

SHALL PREPARE A FIELD REPORT OF FINDINGS AND

RECOMMENDATIONS AND SUBMIT THE REPORT TO THE ARMY

BIOLOGIST.

7. THE ARMY BIOLOGIST SHALL REVIEW THE FINDINGS AND

RECOMMENDATIONS, PREPARE MANAGEMENT MEASURES IN

ACCORDANCE WITH FINDINGS AND 7 A) AND 7 B) BELOW, AND

RETURN A DECISION TO THE PROJECT PROPONENT VIA

MEMORANDUM FOR RECORD WITHIN 2 WEEKS FOLLOWING

RECEIPT OF THE INSPECTION REPORT.

8. MANAGEMENT MEASURES TO MITIGATE RISK. IF THE OPTIONAL

USE OF OFF-SITE AGGREGATE IS APPROVED, THE PTA NATURAL

RESOURCES OFFICE SHALL PREPARE A LIST OF MANAGEMENT

ACTIONS SPECIFIC TO ANY INVASIVE SPECIES FOUND AT THE

OFF-SITE SOURCE, TO MITIGATE ASSESSED RISKS ASSOCIATED

WITH THE USE OF OFF-SITE �UARRY MATERIAL. MANAGEMENT

MEASURES SHALL BE DEVELOPED AND DELIVERED TO THE

PROJECT PROPONENT VIA MEMORANDUM FOR RECORD WITHIN 2

WEEKS OF APPROVAL DATE.

8.1. PLANTS: MANAGEMENT MEASURES FOR INVASIVE PLANT

SPECIES IDENTIFIED AT THE OFF-SITE AGGREGATE

SOURCE WILL INCLUDE APPLICATION OF APPROPRIATE

HERBICIDES IN SITU PRIOR TO REMOVAL OF MATERIAL,

AND MONITORING OF CONSTRUCTION SITES WHERE

OFF-SITE AGGREGATE IS USED. HERBICIDES SELECTED

FOR USE INCLUDE PRE-EMERGENT GENERAL-USE

HERBICIDES LANDMARK XP® (SULFMETHRAN METHYL +

CHLORSULFURAN) OR OUST XP® (SULFMETHRAN METHYL),

AND POST-EMERGENT GENERAL-USE HERBICIDES

ROUNDUP PRO MAX® (GLYPHOSATE) FOR BROADLEAF AND

GRASSY SPECIES AND GARLON 4® (TRICLOPYR) FOR

WOODY SPECIES.MONITORING OF CONSTRUCTION SITES

AT PTA/KMA THAT INCORPORATE OFF-SITE AGGREGATE

WILL BE INCORPORATED INTO THE REGULAR OPERATIONS

OF THE INCIPIENT WEED PROGRAM. IT IS NOTED THAT

MONITORING OF ALL CONSTRUCTION SITES FOR THE

PRESENCE OF INVASIVE PLANT SPECIES IS A

RE�UIREMENT OF THE 2003 BIOLOGICAL OPINION.

8.2. INVERTEBRATES: MANAGEMENT MEASURES FOR INVASIVE

INVERTEBRATE SPECIES IDENTIFIED AT THE OFF-SITE

AGGREGATE SOURCE WILL INCLUDE APPLICATION OF

APPROPRIATE INSECTICIDES IN SITU PRIOR TO REMOVAL OF

MATERIAL. INSECTICIDES SELECTED FOR USE INCLUDE

GENERAL-USE INGESTION INSECTICIDE MAXFORCE ANT BAIT®

(HYDRAMETHYLNON) OR GENERAL-USE CONTACT

INSECTICIDE PYRENONE® (PYRETHRIN). INSECTICIDES WILL

BE APPLIED IN ACCORDANCE WITH LABELING DIRECTIONS TO

ACHIEVE THE MAXIMUM EFFECT.

9. THE PROJECT PROPONENT SHALL BE RESPONSIBLE FOR

IMPLEMENTING ALL MANAGEMENT ACTIONS AS RE�UIRED BY

THE PTA NATURAL RESOURCES OFFICE, IN A TIMELY AND

THOROUGH MANNER, AND IN ACCORDANCE WITH ALL

APPLICABLE RE�UIREMENTS OF THE 2003 BIOLOGICAL OPINION

AND 2008 BIOLOGICAL OPINION.

S O

LI

C

IT

A

TI

O

N N

O

FI

LE

N A

M E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

TI

O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

TE

FI

LE

N U

M B

E R

S

IZ

E

S U

B M

IT

TE

D B

Y

P

LO

T S

C A

LE

D A

TE

M

A R

K D

E S

C R

IP

TI

O N

C O

N

TR

A C

T N

O

D A

TE

A

P P

R

US Army Corps of Engineers

A N

S I D

R H

JG

-T

IT

LB

K

.d gn

IS

S

U E

D A

TE

R E

P A

IR

B

Y R

E P

LA

C

E M

E N

T V

A R

IO

U

S B

U

IL

D

IN

G S

P

O H

A K

U

LO

A T

R A

IN

IN

G A

R E

A (P

TA

IS

LA

N D

O F

H A

W A

II,

H

A W

A

II

/0 5/

SHEET

IDENTIFICATION

A S

N O

TE

D

/0 3/

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

D A

T E

A P

P R fiof Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D R

H J

G -T

IT

L B

K .d g n

IS

S

U E D

A T

E

R E

P A

IR

B

Y R

E P

L A

C E

M E

N T V

A R

IO

U S B

U

IL

D

IN

G S

P O

H A

K U

L O

A T

R A

IN

IN

G A

R E

A P

T A

IS

L

A N

D O

F H

A W

A

II

H A

W A

II

P

C

IF

IC

O

C E

A N

H O

N O

L U

L U

H A

W A

II

/0

/1

IDENTIFICATION

SHEET

A S N

O T

E D

/0

/1

VARIES

BL 65 3

-1 /2

E Q

E Q

3" 3"

SEE DET. 14/A-106

MOUNTED

WALL

MELAMINE

HIGH GRADE

RAISED 1/32"

6" SYMBOL

1/32"

ROMAN RAISED

NEUE 55

HELVETICA

BRAILLE

WITH GRADE 2

DESCRIPTION

ROOM

1" TACTILE

9"

TEXT

TEXTMOUNTED

WALL

MELAMINE

HIGH GRADE

9"

ROMAN RAISED 1/32"

BRAILLE HELVETICA NEUE 55

1" TACTILE TEXT WITH GRADE 2

/4

/8

/4

3/16".

OR DOOR

FINISHED WALL

FOAM TAPE

DOUBLE EMULSION

SHEET

SIDE OF ACRYLIC

BRAILLE TO FRONT

PICTORGRAMS,

3/8" RAISED TEXT,

1 3/16" ACRYLIC SHEET

STRIPS

MESSAGE

/1

/8

/1

/8

/1

ALL AROUND

EDGES

POLISHED

TAPE

DOUBLE FOAM

FINISHED WALL

ALL AROUND

POLISH EDGES

TAPE

DOUBLE FOAM

WHITE ACRYLIC

BONDED TO SIM (1/8")

OR PHOTOPOLYMER

ENGRAVING STOCK

FULL SHEET 1/18"

6" TYP 6" TYP

SIGNSIGN

REGULAR) ON ALUM PANEL

LETTERING (HELVETICA

SENSITIVE WHITE VINYL

SHEETING W/PRESSURE

CORPS BROWN REFLECTED

TYP FOR ALL ROOM SIGNS

NOTE:

PTA

BLDG NUMBER WITH

HT. COORDINATE

ELEVATION FOR MTG

*SEE EXTERIOR

1/4" SPACER

ANCHOR

BOLT W/MASONRY

3/16" DIA HEX HEAD

.080 ALUMINUM SHEET

ANCHOR

BOLT W/MASONRY

3/16" DIA HEX HEAD

NOT REQUIRED

ENAMEL IF REFLECTIVE SHEETING IS

NOTE: FINISH SIGN FACE IN BAKED

1/4"

SMOOTH FACE CMU

ROOF

WALL MOUNT (TYP)

WALL

BUILDING EXTERIOR

1" F/F PULLING ELBOW

PIPE PENETRATION

UNIT

TO STATIC DISCHARGE

MOUNT

VERTICAL

SECTION CUT ELEVATION

FIRE ALARM ANTENNA

ISOMETRIC

& VERTICAL

MOUNT DETAIL

SEE VERTICAL

ISOMETRIC

A, SECTION B, &

ELEVATION, SECTION

SEE WALL MOUNT

MAINTAINABILITY

RECEPTION AND OPTIMIZE

RADIO SIGNAL TRANSMISSION/

LOCATE ANTENNA TO MAXIMIZE

WITH MANUFACTURER DIRECTIONS.

INSTALLED IN STRICT CONFORMANCE

5. SUPPORT ASSEMBLY SHALL BE

300 LBS.

CAPABLE OF SUPPORTING A MINIMUM OF

4. EACH HANGER SUPPORT SHALL BE

153.

GALVANIZED PER ASTM A 123 OR ASTM A

OR A635. FINISH SHALL BE HOT-DIPPED

CONFORMING TO ASTM A575, A576, A36

SHALL BE FABRICATED FROM STEEL

OR ASTM A653 GRADE 33. ALL FITTINGS

CONFORM TO ASTM A1011 SS GRADE 33

3. STEEL CHANNEL MEMBERS SHALL

STUD FRAMING

CONNECTED TO CMU WALL AND METAL

2. SUPPORT FRAMING SHALL BE

PRIOR TO CONSTRUCTION

CONTRACTING OFFICER FOR REVIEW

CALCULATIONS SHALL BE SUBMITTED TO

ASSEMBLY SHOP DRAWINGS AND

PRE-REVIEWED EQUAL. SUPPORT

UNISTRUT CORPORATION OR

CONNECTIONS SHALL BE PROVIDED BY

1. ANTENNA SUPPORT FRAMING AND

UNISTRUT/CHANNEL FRAMING NOTES

AFF, TYP

EL: 7’-4"

B A

EQUAL

SYSTEM OR APPROVED

BY UNISTRUT FRAMING

ALL PARTS SHOWN ARE

TYP.

BOLTS TO WALL,

1/2" DIA. ANCHOR

CLAMP

PIPE/CONDUIT

/8

8" MIN.

O.C., MAX.

BRACKET @ 36"

WALL MOUNTING

DRWGS.

SEE ELECTRICAL

1" DIA. PIPE CONSUIT

WALL MOUNT ELEVATION

FACE OF CMU WALL

MAX.

BRACKET @ 36" O.C.,

WALL MOUNTING

DRWGS.

SEE ELECTRICAL

1" DIA. PIPE CONSUIT

TYP.

BOLTS TO WALL,

1/2" DIA. ANCHOR

CLAMP

PIPE/CONDUIT

IN EPOXY

EXP, BOLT SET

WALL MOUNT SECTION A

FACE OF CMU WALL

TYP.

BOLTS TO WALL,

1/2" DIA. ANCHOR

O.C., MAX.

BRACKET @ 36"

WALL MOUNTING

IN EPOXY

EXP, BOLT SET

WALL MOUNT SECTION B

VERTICAL MOUNT DETAIL

EDGE ANGLE

CONTINUOUS

SYSTEM

ARM SUPPORT

CANTILEVER

UNISTRUT

FITTING

FLAT PLATE

UNISTRUT

PIPE STRAP

STRAP

PIPE

GUTTER

METAL

VERTICAL MOUNT ISOMETRIC

WALL MOUNT ISOMETRIC

A-505

A3

MTL SOFFIT

SEE C2/A501, VOL 0

FOR TYPICAL NOTES,

TYPICAL CMU

HEADER SEE

C5/S005, VOL 0

END TRIM

MTL SOFFIT

EL: 8’-1" AFF, TYP

TYPICAL CMU

HEADER SEE

C5/S005, VOL 0

CONTIUOUS MTL

STUD TRACK

7/8" DEEP 20 GA HAT

CHANNEL @ 16" O.C.

3 5/8" DEEP 20 GA

METAL STUD

@ 16" O.C.

A-502

B U

IL

D

IN

G D

E T

A

IL

S V

O L

U M

E G

E N

IN

F O A

N D D

E T

A

IL

S

C2

ANTENNA MOUNTING DETAILS

D1

SCALE: NTS

EXT BLDG NO SIGN & SECONDARY BLDGS

D2

SCALE: NTS

C1

A1

SCALE: NTS

A2

SCALE: NTS

TYP ROOM SIGN MOUNTING HEIGHT

B4

SCALE: NTS

A4

SCALE: NTS

A3

SCALE: NTS

TYP ROOM SIGN MTG DETAIL - INTERIOR

TYP ROOM SIGN MTG DTL - INT. W/INSERT

TYP ROOM SIGN

TYP RESTROOM ID SIGN TYP EXTERIOR BULDING ID SIGN MTG DETAIL

SCALE: NTS

ROOF OVERHANG DETAIL

SCALE: 1 1/2" = 1’-0"

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

D A

T E

A P

P R fiof Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D R

H J

G -T

IT

L B

K .d g n

IS

S

U E D

A T

E

R E

P A

IR

B

Y R

E P

L A

C E

M E

N T V

A R

IO

U S B

U

IL

D

IN

G S

P O

H A

K U

L O

A T

R A

IN

IN

G A

R E

A P

T A

IS

L

A N

D O

F H

A W

A

II

H A

W

C

IF

IC

O

C E

A N

H O

N O

L U

L U

H A

W A

II

/0

/1

IDENTIFICATION

SHEET

A S N

O T

E D

/0

/1

CONC SIDEWALK

SIDE ELEVATION

SL

(SEE 3/CG501, VOL 0 FOR DETAIL)

5’-0"SEE CIVIL

WATER PROOF MEMBRANE

APPROVED EQUAL

BOBRICK #B985 OR

BASIS OF DESIGN:

HANGER

STAINLESS STEEL

HEAVY DUTY

STAIR ELEVATION

S P

L

IT

F

A C

E C

M U

BIBB

HOSE

C M

U F

A C

E

M

O O

T H

1’-0"

11"

RAILING

DIA. STEEL PIPE

PAINTED 1 1/2"

(4

E Q R

IS

E R

S

1’-0"

1"

GRADE DETAIL

FOR CONC STAIR ON

SEE STRUCTURAL

CONCRETE STAIR.

BEYOND

COLUMN

CONC

BEYOND

DOWNSPOUT

BEYOND

LOW WALL EDGE

METAL FRAME

METAL FRAME

1’ - 3"

LOCKERS

AT END OF

W/END PANEL

SLOPED TOP

BASE

ENCLOSED

COAT HOOK

HANGER ROD

LK-1

METAL SHELF

A-503

B U

IL

D

IN

G D

E T

A

IL

S V

O L

U M

E G

E N

IN

F O A

N D D

E T

A

IL

S

C2

A1

SCALE: 3/4" = 1’-0"

STAIR & RAILING DETAIL

SCALE: 3/4" = 1’-0"

TYPICAL BOOT WASH DETAIL

A4

TYPICAL LOCKER SECTION

SCALE: 1 1/2"" = 1’-0"

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

D A

T E

A P

P R fiof Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D R

H J

G -T

IT

L B

K .d g n

IS

S

U E D

A T

E

R E

P A

IR

B

Y R

E P

L A

C E

M E

N T V

A R

IO

U S B

U

IL

D

IN

G S

P O

H A

K U

L O

A T

R A

IN

IN

G A

R E

A P

T A

IS

L

A N

D O

F H

A W

A

II

H A

W

C

IF

IC

O

C E

A N

H O

N O

L U

L U

H A

W A

II

/0

/1

IDENTIFICATION

SHEET

A S N

O T

E D

/0

/1

42" MIN.

12" MAX.

54" MIN.

36" MIN.

8" MIN.

M

IN

C L E

A R

18" TYP.

30" MIN.

M

IN

7" MIN. / 9" MAX. 16" MIN. / 18" MAX.

T O

IL

E T

U N

IS

X

M A

X

18" TYP.

5’ - 0" CLR

M

IN

1’ - 6"

6" MAX

T .O L

A V

6" MIN

M

IN

S U

R F

A C

E B .O

R E

F L E

C T

IV

E U

N

IS

E X T

O

IL

E T

M A

X

M A

X

(1

M

IN

M A

X

(1

M

IN

T .O F

L U

S H H

A N

D L E

M A

X

M A

X

M

IN

M A

X

M

IN

T .O

H O

O K

M

X

M A

X

DISPENSER

MOUNT SOAP

SURFACE

GRAB BAR

TSCD

TOILET ONLY)

DISPOSAL (WOMEN’S

SANITARY NAPKIN

MIRROR

24"x36"

CL

LC

CLEARANCE

TOE AND KNEE

CLEARANCE

FLOOR

LAVATORY

(ACCESSIBLE STALL)

TYPICAL FRONT ELEVATION

TYPICAL SIDE ELEVATION

LAVATORY - TYPICAL FRONT ELEVATION

LAVATORY -

TYPICAL FLOOR PLAN

LAVATORY -

(ACCESSIBLE STALL)

TYPICAL SIDE ELEVATION

ONLY

AND RESTROOM

IN WOMEN’S

DISPOSAL

NAPKIN

SANITARY ROBE HOOK

FINISH SCHEDULE

VOL NO. NAME HEIGHT FLOOR FINISH CEILING FINISH COMMENTS

VOL 1

VOL 2

BARRACKS - LARGE 8’ - 8" AFF

DOOR DOOR FRAME

GYP-1

FINISH LEGEND

SYMBOL MATERIAL PATTERN/COLOR COMMENTS

GYPSUM BOARD

CT-1 CERAMIC TILE

SLIGHTLY BEVELED MODIFIED STRAIGHT EDGE

GRT-1 GROUT

NON-STAINING, DRY-SET GROUT FOR WALLS, COLOR TO MATCH TILE

COMMERCIAL PORTLAND CEMENT GROUT, WATER RESISTANT,

CONC-1 SEALED CONCRETE

PT-1

CMU WALL)

PAINT (INTERIOR

PT-2

WALL @ VOL 3 & 4)

PAINT (INTERIOR CMU

PT-3

& DOOR FRAMES)

PAINT (METAL DOORS

WILLIAMS - FOGGY DAY SW 6235

SEMI-GLOSS PAINT, COLOR: SHERWIN

COLOR: SHELL WHITE SW 8917

SEMI-GLOSS INTERIOR LATEX PAINT,

GP ADMIN - SMALL 8’ - 8" AFF

8’ - 8" AFF

8’ - 8" AFF

8’ - 8" AFF

9’ - 6" AFF

VOL 3

VOL 4

VOL 5

VOL 9 GP ADMIN - LARGE

VOL 10

VOL 7

DUPLEX

SHOWER/LATRINE

LATRINE ONLY

LAUNDRY

GATHERING

COMMUNITY

BARRACKS - MEDIUM

8’ - 8" AFF

8’ - 8" AFF

PT-3

PT-3

PT-3

PT-3

PT-3

PT-3

PT-3

PT-3

PT-3

PT-3

PT-3

PT-3

PT-3

PT-3

CEILING (GYP-1)

GYPSUM BOARD

CEILING (GYP-1)

GYPSUM BOARD

CEILING (GYP-1)

GYPSUM BOARD

CEILING (GYP-1)

GYPSUM BOARD

CEILING (GYP-1)

GYPSUM BOARD

CEILING (GYP-1)

GYPSUM BOARD

CEILING (GYP-1)

GYPSUM BOARD

CLCL

LC

CL

CL

TYP FRONT VIEW

URINAL

TYP PLAN VIEW

URINAL

SPACE

CLEAR

30" X 48"

- PANEL

METAL SOFFIT

EXT. WALL FINISH INT. WALL FINISH

CMU (PT-1)

PAINT ON

CMU (PT-2)

PAINT ON

CMU (PT-2)

PAINT ON

CMU (PT-1)

PAINT ON

CMU (PT-1)

PAINT ON

CMU (PT-1)

PAINT ON

CMU (CMU-1)

PAINT ON

GP ADMIN - (PT-1)

BID OPTION 3)

UNISEX LATRINE - (CT-1,

CMU (CMU-1)

PAINT ON

CMU (CMU-1)

PAINT ON

CMU (CMU-1)

PAINT ON

CMU (CMU-1)

PAINT ON

CMU (CMU-1)

PAINT ON

CMU (CMU-1)

PAINT ON

VOL 8

VOL 6 DFAC

INDUSTRIAL BUILDING

FOR ALTERNATE FINISHES

SEE BID OPTIONS ON VOL 0, A002-A003

FOR ALTERNATE FINISHES

SEE BID OPTIONS ON VOL 0, A002-A003

FOR ALTERNATE FINISHES

SEE BID OPTIONS ON VOL 0, A002-A003

FOR ALTERNATE FINISHES

SEE BID OPTIONS ON VOL 0, A002-A003

FOR ALTERNATE FINISHES

SEE BID OPTIONS ON VOL 0, A002-A003

FOR ALTERNATE FINISHES

SEE BID OPTIONS ON VOL 0, A002-A003

FOR ALTERNATE FINISHES

SEE BID OPTIONS ON VOL 0, A002-A003

FOR ALTERNATE FINISHES

SEE BID OPTIONS ON VOL 0, A002-A003

CMU-1

SEALER AS SPECIFIED

SEALER AS SPECIFIEDSEALED CMU

(CONC-1)

WATER REPELLENT

(CONC-1)

WATER REPELLENT

(CONC-1)

WATER REPELLENT

(CONC-1)

WATER REPELLENT

(CONC-1)

WATER REPELLENT

(CONC-1)

WATER REPELLENT

(CONC-1)

WATER REPELLENT

(CONC-1)

WATER REPELLENT

TPD

(TPD)

DISPENSER

PAPER

TOILET

(FEC)

CABINET

EXTINGUISHER

FIRE

INDUSTRIAL COATING, COLOR: SHELL WHITE SW 8917

SEMI-GLOSS INTERIOR WATERBORNE LIGHT

BRIGHT GLAZED FINISH. COLOR: 0161 "URBAN PUTTY"

4 1/4" X 4 1/4", DUST PRESSED, WHITE NON-VITREOUS BODY,

LK-1

COLOR: 028 "GRAY"

15"x15"x72" TYPE STC-1 SINGLE TIER, ATTACHED TO 6" CLOSED BASE, W/OPEN SHELF

LOCKERS (METAL)

SEMI-GLOSS INTERIOR LATEX PAINT, COLOR: SHELL WHITE SW 8917 WATER-RESISTANT GYPSUM BOARD @ ADMIN LARGE UNI-SEX LATRINE - BID OPTION 3 (WALL & CEILING)

STALL)

(ACCESSIBLE

DISPENSER

SEAT COVER

TOILET

(TSCD)

IN RESTROOM

DISPENSER

SEAT COVER

TOILET SOAP HOLDER

A-504

C1

TYPICAL MOUNTING HEIGHT

SCALE: NTS

F

IN

IS

H S

C H

E D

U L E L

E G

E N

D T

Y P

IC

A L M

O U

N T

IN

G H

E

IG

H T

V O

L U

M E G

E N

IN

F O A

N D D

E T

A

IL

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

D A

T E

A P

P R fiof Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D R

H J

G -T

IT

L B

K .d g n

IS

S

U E D

A T

E

R E

P A

IR

B

Y R

E P

L A

C E

M E

N T V

A R

IO

U S B

U

IL

D

IN

G S

P O

H A

K U

L O

A T

R A

IN

IN

G A

R E

A P

T A

IS

L

A N

D O

F H

A W

A

II

H A

W

C

IF

IC

O

C E

A N

H O

N O

L U

L U

H A

W A

II

/0

/1

IDENTIFICATION

SHEET

A S N

O T

E D

/0

/1

ELEVATION

PLAN

SECTION

EDGES, TYP.

EASE ALL OF

SEE DETAIL C2/A-505

METAL DOWNSPOUT,

SEE DETAIL C3/A-505

SPLASH BLOCK,

1’- 4"

2"

1’-0"6 1/8"

/2

EQ

EQ

EQ

2"

EQ

ASSEMBLY

EXTERIOR WALL

DOWNSPOUT

4" DIA. METAL

SST BOLT W/ BLKG

STRAP W/ 1/4" OC X 2"

PAINTED METAL

2" (W) X 3/16" THICK

FINISH FLOORFINISH FLOOR

(WHERE OCCURS)

CEILING

SEALANT

CONT NON-HARDENING

STRUCTURE

UNDERSIDE OF

SEALANT

CONT NON-HARDENING

FINISH FLOOR

STRUCTURE

UNDERSIDE OF

LATRINE

UNI-SEX

-LARGE

GP ADMIN

EXIST STRUCTURE

EXTEND STUD TO

STRUCTURE

UNDERSIDE OF

T.O. WALL

EL: +7’-10"

6" METAL STUDS @ 16" O.C.

EXHAUST DUCT

DRAFT DAMPER

SPRING LOADED BACK

SET CAP IN SEALANT

WALL CAP

CMU EXP. FASTENER, TYP

CMU WALL

GLASS MAT GYPSUM BOARDFOR LIMITS AND PATTERN

SEE INTERIOR ELEVATIONS

(BID OPTION 3).

BOARD @ UNI-SEX LATRINE

CT THIN SET ON BACKER

FOR LIMITS AND PATTERN

SEE INTERIOR ELEVATIONS

(BID OPTION 3).

BOARD @ UNI-SEX LATRINE

CT THIN SET ON BACKER

CMU WALL

PARTIAL HEIGHT

WALL W/TILE

GYP/GLASS MAT

6" STUD

W/ EPOXY PAINT

CMU WALL

W/ EPOXY PAINT

CMU WALL

W/ EPOXY PAINT

CMU WALL

8" CMU WALL

FULL HEIGHT

COUNTER FLASHING

SHEET METAL

SEALANT

EDGE METAL

PANS TO ENGAGE

FOLD PANEL

EDGE-METAL FLASHING

DOWNSLOPE PERIMETER

UNDERLAYMENT

METAL ROOF PANEL

PANEL CLIP

METAL GUTTER

SUPPORT

GUTTER BRACKET

BRACKETS

PLACED BETWEEN

GUTTER SPACER

METAL DOWNSPOUT

SEE STRUCT

CONT FASCIA

END TRIM

SEE STRUCT

CLIP ANGLE

SOFFIT

METAL

FLASHING FASCIA

SHEET METAL

METAL ROOFING

PENTRATION

CONDUIT

RUNOFF

TO FACILITATE

SEALANT TOOLED

FLASHING

PENETRATION

PREFORMED

OF SEALANT

CONTINUOUS BEAD

RING IN

SET SCUREMENT

PENETRATION

FIX PANEL AT

DECK SO AS NOT TO

PANEL AND NOT TO

FLANGE TO ROOF

FLASHING COLLAR

FASTENERS SECURE

GASKETED

DRAWBAND

SST

A-505

B U

IL

D

IN

G D

E T

A

IL

S V

O L

U M

E G

E N

IN

F O A

N D D

E T

A

IL

S

B3

PARTITION TYPES

SCALE: NTS

C3

CONC SPLASH BLOCK ISOMETRIC DETAIL

SCALE: 1 1/2" = 1’-0"

C1

SCALE: 1 1/2" = 1’-0"

GUTTER DETAIL

C2

GUTTER DOWNSPOUT DETAIL

SCALE: 6" = 1’-0"

A1

SCALE: NTS

EXHAUST WALL CAP

A2

EAVE WITH GUTTER DETAIL

SCALE: 3" = 1’ - 0"

A4

SCALE: 3" = 1’ - 0"

TYPCIAL CONDUIT PENETRATION DETAIL

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

D A

T E

A P

P R fiof Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D R

H J

G -T

IT

L B

K .d g n

IS

S

U E D

A T

E

R E

P A

IR

B

Y R

E P

L A

C E

M E

N T V

A R

IO

U S B

U

IL

D

IN

G S

P O

H A

K U

L O

A T

R A

IN

IN

G A

R E

A P

T A

IS

L

A N

D O

F H

A W

A

II

H A

W

C

IF

IC

O

C E

A N

H O

N O

L U

L U

H A

W A

II

/0

/1

IDENTIFICATION

SHEET

A S N

O T

E D

/0

/1

HEADRAIL

ALUMINUM

(S T

D

SHOE

PLASTER

(OPTIONAL)

SHOWER SEAT

(A .F .F

/2

/2

SHOWER BASE

TERRAZO

PREFABRICATED

COMPARTMENTS

DRESSING

SHOWER/

PLASTIC

SOLID

CURTAIN ROD

CURTAIN AND

FRONT ELEVATION

(A .F .F

BRACKETS

CONTINUOUS

C O

N N

B A

C K W

A L L S P

IL

A S

T E

R /P

A N

L

H

O W

E R C

O R

N E B

R A

C K

E T S

T

C O

N T

B R

A C

K E

T S

/2

H

IG

H C

O N

T

IN

U O

U S A

L U

M

36" BASE

COMPARTMENT

SHOWER

COMPARTMENT

DRESSING

COMPARTMENTS

SHOWER/DRESSING

SOLID PLASTIC

PARTITIONS

BETWEEN

JOINTS

SEAL ALL

BENCH

FIXED

RABBET JOINT

SEALANT AT

SHOWER BASE

TERRAZO

FABRICATED

PRE

SEE PLAN

7"3’-3"

CURTAIN ROD

CURTAIN AND

SECTION

A-506

B U

IL

D

IN

G D

E T

A

IL

S V

O L

U M

E G

E N

IN

F O A

N D D

E T

A

IL

S

A1

SHOWER & DRESSING COMPARTMENT DETAIL

AT CONC WALLS

OC, PROVIDE EXP SHIELDS

1/4" SST FASTENERS @ 16"

20 GA SST FLASHING

CAP FLASHING

SEALANT

SST CORNER JOINT

16 GA SST ANGLE

SHOWER PANEL

SCALE: 3" = 1’-0"

#8 SST SCREWS @ 6" OC

CAP FLASHING

20 GA SST

JOINT

SST CORNER

PANEL

SHOWER

END WALL - BACK CHASE PLAN -BACK

END WALL - FRONT CHASE PLAN -FRONT END WALL - CORNER

CAP

SST TOP

JOINT

SST CORNER

SEAMING

SHOWER

RECEPTOR

SHOWER

RECEPTOR

SHOWER

SST CORNER JOINT

SEALANT

SHOWER RECEPTOR

RECEPTOR BASE

SST CORNER JOINT

SHOWER PANEL

SHOWER PANEL

W/ANCHORS

W/#12 SST SCREWS

STRIP, FASTEN TO WALL

20 GA SST SEAMING

BASE

RECEPTOR

SHOWER PANEL

PANEL

SHOWER

JOINT

SST CORNER

PANEL, FASTEN TO WALL

SHOWER SEAMING

BENCH

SHOWER PANEL

3"

7"

PANEL, FASTEN TO WALL

SHOWER SEAMING

BENCH

SHOWER PANEL

SECTION - BACK WALL AT TOP SECTION - CHASE AT TOP

ELEVATION AT TOP

SECTION - CHASE

PANEL

SEAMING

SHOWER

SECTION - CHASE AT BASE ELEVATION - CHASE BASESECTION - BACK WALL AT BASE

BRACKET

CONTINUOUS

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

D A

T E

A P

P R fiof Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D R

H J

G -T

IT

L B

K .d g n

IS

S

U E D

A T

E

R E

P A

IR

B

Y R

E P

L A

C E

M E

N T V

A R

IO

U S B

U

IL

D

IN

G S

P O

H A

K U

L O

A T

R A

IN

IN

G A

R E

A P

T A

IS

L

A N

D O

F H

A W

A

II

H A

W

C

IF

IC

O

C E

A N

H O

N O

L U

L U

H A

W A

II

/0

/1

IDENTIFICATION

SHEET

A S N

O T

E D

/0

/1

D

D

3’ 10"

3’ 0"

1 3/4" THICK, HOLLOW METAL,

FLUSH PANEL METAL DOOR.

3’ 6"

3’ 4"

D

6’ 0"

6’ 4"

DIMENSIONS SHOWN ARE TO ROUGH OPENING, TYP.

1 3/4" THICK, HOLLOW METAL,

FLUSH PANEL METAL DOOR.

1 3/4" THICK, HOLLOW METAL,

FLUSH PANEL METAL DOOR.

UTILITY CLOSET (10)

5’ 0" AT VOL 4

W

W

8’ 0" 4’ 0"

W

4’ 0"

W

8’ 0"

DIMENSIONS SHOWN ARE TO ROUGH OPENING, TYP.

PREFINSIHED ALUMINUM SLIDING WINDOWS, TYP.

SILL

4" PRECAST

SILL

4" PRECAST

SILL

4" PRECAST

SILL

4" PRECAST

GLASS

LOW EMISSIVITY INSULATING

NO. 4 SURFACE.

TRANSLUCENT FILM ON

AS SPECIFIED WITH

1/4" LAMINATED GLASS

GLASS

LOW EMISSIVITY INSULATING

GLASS

LOW EMISSIVITY INSULATING

NO. 4 SURFACE.

TRANSLUCENT FILM ON

AS SPECIFIED WITH

1/4" LAMINATED GLASS

GLASS

LOW EMISSIVITY INSULATING

SILL

BELOW

4" CMU

SILL

BELOW

4" CMU

SILL

BELOW

4" CMU

SILL

BELOW

4" CMU

L

2’ 8"

3’ 4" 1’ 4" 2’ 0"

L

L

L

DIMENSIONS SHOWN ARE TO ROUGH OPENING, TYP.

PREFINSIHED ALUMINUM STORM-RESISTANT LOUVERS, TYP.

7 5/8 "

EQ.

5 1/2 "

EQ.

D O

O R S

IZ

E

/8

DOOR SIZE2"

D O

O R S

IZ

E /2

4"

EACH SIDE

CONT. SEALANT

DOOR

DOOR

BEYOND

FRAME

DOOR

BITUMINOUS MATERIAL

WITH CORROSION-INHIBITING

INSIDE FACE OF FRAMES

SOLID GROUTED. COAT

DOOR FRAMES SHALL BE

BITUMINOUS MATERIAL

WITH CORROSION-INHIBITING

INSIDE FACE OF FRAMES

SOLID GROUTED. COAT

DOOR FRAMES SHALL BE

OVER CMU WALL

PLASTER FINISH

SKIM COAT

BID OPTION 11:

AS SPECIFIED

SET IN SEALANT

THRESHOLD

WALL

PERPENDICULAR

TO THE ADJACENT

ON THE HINGE SIDE

TYP

8"

METAL FRAME

PAINTED

ANCHORS, TYP.

W/ MASONRY

METAL FRAME

PAINTED

OVER CMU WALL

PLASTER FINISH

SKIM COAT

BID OPTION 11:

7 5/8 "

1/2 "4"

/8

/2

1 1/4 "

/2

R .O

R.O.

R .O

4"

/8

9 5/8 "

SCREEN

REMOVABLE

WINDOW

EACH SIDE

CONT. SEALANT

FRAME

ALUMINUM

EACH SIDE

CONT. SEALANT

FRAME

ALUMINUM

WINDOW

SCREEN

REMOVABLE

WINDOW

SILL

CONCRETE

PRECAST

OVER CMU WALL

PLASTER FINISH

SKIM COAT

BID OPTION 11:

OVER CMU WALL

PLASTER FINISH

SKIM COAT

BID OPTION 11:

OVER CMU WALL

PLASTER FINISH

SKIM COAT

BID OPTION 11:

CONCRETE SILL

PRECAST

WINDOW SILL

4" CMU UNDER

7 5/8 "

/8

M .O

M.O.

M .O

SCREEN

REMOVABLE

WINDOW

EACH SIDE

CONT. SEALANT

3 1/8"4"1/2"

/2

/8

3 1/8"4" 1/2"

SCREEN

BIRD/INSECT

LOUVER MFR

CLIP ANGLE BY

LOUVER MFR

SEALANT BY

SET ON BED OF

METAL SILL PAN

METAL LOUVER

LOUVER MFR

CLIP ANGLE BY

METAL LOUVER

SCREEN

BIRD/INSECT

SCREEN

BIRD/INSECT

LOUVER MFR

CLIP ANGLE BY

EACH SIDE

SEALANT

CONT.

OVER CMU WALL

PLASTER FINISH

SKIM COAT

BID OPTION 11: OVER CMU WALL

PLASTER FINISH

SKIM COAT

BID OPTION 11:

OVER CMU WALL

PLASTER FINISH

SKIM COAT

BID OPTION 11:

D

QTY MARK #

D

D

LAUNDRY (VOL 5)

THK COMMENT

SHOWER/LATRINE (VOL 3)

SHOWER/LATRINE (VOL 3)

LAUNDRY STOR INT (VOL 5)

BARRACKS (VOL 10)2

ADMIN (VOL 2)2 1

1 9

BARRACKS (VOL 1)2 7

ADMIN (VOL 9)2 4

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

HMD

HMD

HMD

HMD

HMD

HMD

HMD

HMD

DRSET

HW

FR

HMF

HMF

HMF

HMF

HMF

HMF

HMF

HMF

DR BETWEEN LAUNDRY & STOR

MODE

SGL

SGL

SGL

SGL

SGL

SGL

SGL

PR

DR INTO LAUNDRY

DR INTO CHASE SPACE

FINISH

PT-2

PT-2

PT-2

PT-2

PT-2

PT-2

PT-2

PT-2

SHOWER/LATRINE (VOL 3) 3 SGL 1 3/4" HMD HMF PT-2

3 SGL 1 3/4" HMD HMF PT-2LATRINE (VOL 4)

LATRINE (VOL 4)1 10 1 3/4" HMD HMFPR DR INTO UTILITY CLOSETPT-2

MAIN ENTRANCES

MAIN ENTRANCES

1 LAUNDRY (VOL 5) 1 1 3/4" HMD HMFSGL DR INTO STORAGEPT-2

EXT DR (HW#4), UNI-SEX DR (BID OP#3 -HW#2)

DR INTO STORAGE ROOM

A-510

D E

T A

IL

S D

O O

R

W

IN

D O

W

A N

D S

IG

N A

G E

V O

L U

M E G

E N

IN

F O A

N D D

E T

A

IL

S

SCALE: 1/4" = 1’-0"

B1

WINDOW TYPES

SCALE: 1/4" = 1’-0"

A1

LOUVER TYPES

SCALE: 1/4" = 1’-0"

C1

DOOR TYPES

SCALE: 3" = 1’-0"

C3

DOOR HEAD

SCALE: 3" = 1’-0"

C4

DOOR JAMB

SCALE: 3" = 1’-0"

C5

DOOR THRESHOLD

SCALE: 3" = 1’-0"

B3

WINDOW HEAD

SCALE: 3" = 1’-0"

B4

WINDOW JAMB

SCALE: 3" = 1’-0"

B5

WINDOW SILL

SCALE: 3" = 1’-0"

A3

LOUVER HEAD

SCALE: 3" = 1’-0"

A4

LOUVER JAMB

SCALE: 3" = 1’-0"

A5

LOUVER SILL

S-001

R H

J

V O

L S -0

.d g n

S T

R U

C T

U R

A L G

E N

E R

A L N

O T

E S

V O

L U

M E G

E N

IN

F O

A N

D D

E T

A

IL

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

D A

T E

A P

P R

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

IS

S

U E D

A T

E

R E

P A

IR

B

Y R

E P

L A

C E

M E

N T V

A R

IO

U S B

U

IL

D

IN

G S

P O

H A

K U

L O

A T

R A

IN

IN

G A

R E

A P

T A

IS

L

A N

D O

F H

A W

A

II

H A

W

C

IF

IC

O

C E

A N

H O

N O

L U

L U

H A

W A

II

/0

/1

IDENTIFICATION

SHEET

A S N

O T

E D

/0

/1

PERCENT RELATIVE COMPACTION.

ABOVE THE OPTIMUM MOISTURE CONTENT AND COMPACTED TO AT LEAST 95

EXCEEDING 6 INCHES IN LOOSE THICKNESS, MOISTURE-CONDITIONED TO

STRUCTURAL FILL MATERIALS SHOULD BE PLACED IN LEVEL LIFTS NOT 7.

A WELL-GRADED MATERIAL.

TO PROVIDE THE REQUIRED GRADATION AND PARTICLE SIZES TO DEVELOP

LARGE-SIZED ROCK FRAGMENTS OR BOULDERS SHOULD BE CONSIDERED

TO PRODUCE A WELL-GRADED MATERIAL, OFF-SITE CRUSHING OF

IF THE EXCAVATED ON-SITE MATERIALS DO NOT CONTAIN SUFFICIENT FINES 6.

REQUIREMENTS.

PROCESSED TO MEET MAXIMUM PARTICLE SIZE AND GRADATION

STRUCTURAL FILL MATERIALS, PROVIDED THAT THE MATERIALS ARE

EXCAVATED ON-SITE MATERIALS MAY BE RE-USED AS A SOURCE OF

PREVENT THE OCCURRENCE OF VOIDS IN THE COMPACTED MASS. THE

MATERIALS 1-1/2 INCHES IN LARGEST DIMENSION WITH SUFFICIENT FINES TO

STRUCTURAL FILL MATERIALS SHALL CONSIST OF WELL-GRADE GRANULAR 5.

STRUCTURAL FILL AS REQUIRED.

MATERIAL, INCLUDING ASH AND ORGANICS AND REPLACE WITH COMPACTED

CONTRACTOR'S GEOTECHNICAL ENGINEER. REMOVE UNSATISFACTORY

SHALL BE NOTIFIED. FOOTINGS MAY BE ALTERED AS REQUIRED BY THE

EXPECTED CONDITIONS, THE CONTRACTOR'S GEOTECHNICAL ENGINEER

SOIL ENCOUNTERED AT THESE DEPTHS APPEAR UNSTABLE AND VARY FROM

FOOTINGS SHALL BE PLACED ON UNDISTURBED EXISTING SOIL. SHOULD 4.

AREA OF WORK AS NECESSARY.

DRAWINGS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS IN

ALL EXISTING BUILDING DIMENSIONS ARE BASED ON AVAILABLE EXISTING 5.

CONCRETE AND CMU WALLS AND SLABS.

NEW PIPES AND CONDUITS SHALL NOT BE EMBEDDED IN EXISTING 4.

NEW OPENINGS IN EXISTING SLABS AND WALLS SHALL NOT BE OVERCUT.3.

TO THE CONTRACTING OFFICERS'S ATTENTION PRIOR TO STARTING WORK.

STARTING WORK. ANY DISCREPANCIES WITH DRAWINGS SHALL BE BROUGHT

DIMENSIONS SHALL BE VERIFIED BY CONTRACTOR IN FIELD PRIOR TO

SEE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. ALL EXISTING 2.

DEMOLITION WORK.

CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AND BRACING FOR ALL 1.

DEMOLITION NOTES

REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.4.

FIBER WRAP SYSTEM SHALL CONFORM TO ACI 440.2R.3.

AS A MINIMUM.

LOCATIONS AND FORCE DEMANDS THAT FIBER WRAP SYSTEM MUST RESIST

STRUCTURAL DRAWINGS BY NAGAMINE OKAWA ENGINEERS INC. PROVIDE 2.

FOR REVIEW AND COMMENT.

WRAP DESIGN ENGINEER SHALL BE PROVIDED TO CONTRACTING OFFICER

CALCULATIONS AND SHOP DRAWINGS STAMPED AND SIGNED BY FIBER

AND SHALL BE DESIGNED BY A LICENSED STRUCTURAL ENGINEER.

FIBER WRAP STRENGTHENING SHALL BE PROVIDED BY THE CONTRACTOR 1.

FIBER WRAP STRENGTHENING

SUSPENDED CEILINGS, MECHANICAL DUCTS, PIPING, ETC.

METAL DECKING WITHOUT TOPPING SHALL NOT BE USED TO SUPPORT 12.

ALL WELDS SHALL HAVE TOUCH-UP.

MANUFACTURER'S RECOMMENDATIONS. UPON COMPLETION OF ERECTION,

INDICATED ON THE DRAWINGS AND IN ACCORDANCE WITH

BE ATTACHED TO ALL SUPPORTING STEEL MEMBERS BY WELDING AS

MINIMUM BEARING OF DECKING ON SUPPORTS SHALL BE 2". SHEETS SHALL 11.

SHALL SPAN OVER THREE OR MORE SUPPORTS.

PROTECTIVE COATING OF ZINC (G60). SEE SPECIFICATIONS. DECK UNITS

CONFORMING TO ASTM A446, GRADE A. THE STEEL SHALL HAVE A METAL

STEEL SHEETS HAVING A MINIMUM YIELD STRENGTH OF 33,000 PSI AND

THE DRAWINGS. DECKING AND ALL ACCESSORIES SHALL BE FORMED FROM

THE STEEL DECKING SHALL BE OF THE TYPE AND GAUGE AS CALLED FOR ON 10.

5,000 PSI. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.

CONCRETE WALLS, ETC., SHALL BE NON-SHRINK, NON-STAINING, WITH f'c =

ALL GROUT (OR DRYPACK) BELOW BASE PLATES, BEAMS BEARING ON 9.

COATED WITH TWO COATS OF ZINC RICH PRIMER.

ASTM A123 OR A153. ALL WELDS AFTER HOT DIP GALVANIZING SHALL BE

HOT DIP GALVANIZED STEEL REFERENCED ON PLAN SHALL CONFORM TO 8.

SPECIFICATIONS.

CODE AWS D1.1-04 OF THE AMERICAN WELDING SOCIETY; SEE

ALL WELDS SHALL BE IN CONFORMITY WITH THE STRUCTURAL WELDING 7.

MASONRY SHALL BE CLEAN AND LEFT UNPAINTED.

ALL STRUCTURAL STEEL SURFACES THAT ARE ENCASED IN CONCRETE OR 6.

SIZE OF BOLT USED, UNLESS OTHERWISE NOTED.

BOLT HOLES IN STEEL SHALL BE 1/16" LARGER DIAMETER THAN NOMINAL 5.

REVIEW BEFORE FABRICATION.

ALL STRUCTURAL STEEL RESPECTIVELY, FOR CONTRACTING OFFICER'S

THE STRUCTURAL STEEL FABRICATOR SHALL FURNISH SHOP DRAWINGS OF 4.

GALVANIZED.

RODS EPOXY EMBEDDED SHALL CONFORM TO ASTM A36 AND BE HOT DIP

CONFORMING TO ASTM A325 OR A490. UNLESS OTHERWISE NOTED, ANCHOR

UNLESS OTHERWISE NOTED. USE ALTERNATIVE DESIGN FASTENER

ALL BOLTS SHALL CONFORM TO ASTM A325N HIGH STRENGTH BOLTS, 3.

= A500, GRADE BTUBES

= A500, GRADE BPIPES

= A36PLATES, MISC. STEEL

CHANNELS, ANGLES, TEES,

= A992, GRADE 50WIDE FLANGES

DESIGNATIONS:

STRUCTURAL STEEL SECTIONS SHALL CONFORM TO THE FOLLOWING ASTM 2.

FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS."

ACCORDANCE WITH THE "AISC SPECIFICATION FOR THE DESIGN,

STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN 1.

STRUCTURAL STEEL

STEEL" OF THE AMERICAN WELDING SOCIETY.

CONFORM TO AWS D1.4 "AWS STRUCTURAL WELDING CODE - REINFORCING

SHOWN ON THE DRAWINGS. WELDING OF REINFORCING STEEL SHALL

WELDING OF REINFORCING STEEL IS NOT PERMITTED UNLESS OTHERWISE 8.

FROM REVIEWED DRAWINGS ONLY.

CONTRACTING OFFICER'S REVIEW PRIOR TO FABRICATION. FABRICATE

CONTRACTOR SHALL SUBMIT REINFORCING BAR LAYOUTS AND DETAILS FOR 7.

MODIFIED BY THE PROJECT DRAWINGS AND SPECIFICATIONS.

CONFORMANCE WITH THE "ACI DETAILING MANUAL - 2004" (SP-66) AS

ALL REINFORCING STEEL SHALL BE DETAILED AND PLACED IN 6.

ALL REINFORCING BAR BENDS SHALL BE MADE COLD.5.

SECURELY TIED IN PLACE BEFORE CONCRETE IS POURED.

ANCHOR BOLTS, DOWELS AND OTHER EMBEDDED ITEMS ARE TO BE 4.

DRAWINGS.

REINFORCING SPLICES SHALL BE MADE ONLY WHERE INDICATED ON THE 3.

U.O.N.

AND SPACING OR NUMBERS AS THE VERTICAL REINFORCING RESPECTIVELY,

DOWELS BETWEEN FOOTING AND WALL SHALL BE THE SAME GRADE, SIZE 2.

REQUIREMENTS OR ASTM A706 WHERE WELDING IS REQUIRED.

REINFORCING BARS SHALL CONFORM TO ASTM A-615 GRADE 60 1.

REINFORCING STEEL

AMPLITUDE OF 1/4".

ALL ROUGHENED SURFACES IN CONCRETE SHALL BE MADE WITH A MINIMUM 11.

SHALL NOT BE USED.

CONCRETE ADMIXTURES CONTAINING CHLORIDE OR CHLORIDE SALTS 10.

SPECIFYING CONCRETE POURS IN UPCOMING THREE WEEKS.

CONTRACTOR SHALL PROVIDE THE CONTRACTING OFFICER A SCHEDULE 9.

BEFORE USE.

ARCHITECTURAL FINISH SHALL BE APPROVED BY THE FINISH SUPPLIER

CURING COMPOUNDS USED ON CONCRETE THAT IS TO RECEIVE AN 8.

SHOWN ON THE DRAWINGS.

NOTIFY THE CONTRACTING OFFICER IN ADVANCE OF CONDITIONS NOT

CONFLICT. CORING IN CONCRETE IS NOT PERMITTED EXCEPT AS SHOWN.

CONCRETE BEFORE PLACING. DO NOT CUT ANY REINFORCING WHICH MAY

PROVIDE SLEEVES FOR PLUMBING AND ELECTRICAL OPENINGS IN 7.

SHALL BE WELL SECURED IN POSITION PRIOR TO PLACING CONCRETE.

ALL REINFORCING BARS, ANCHOR BOLTS AND OTHER CONCRETE INSERTS 6.

2" CLEAR TO STIRRUPS AND TIESBEAMS AND COLUMNSD.

1" CLEAR TO REINFORCINGWALLSC.

1 1/2" CLEAR AT TOP (EXTERIOR)

1" CLEAR AT TOP (INTERIOR)SLAB ON GRADEB.

3" CLEAR TO REINFORCING AGAINST EARTH

CONCRETE DIRECTLY A.

BE AS FOLLOWS (U.O.N.):

CLEAR COVERAGE OF CONCRETE OVER OUTER REINFORCING BARS SHALL 5.

PROJECT SITE.

SHALL ACCOUNT FOR TRAVEL TIME AND TEMPERATURE CONDITIONS AT THE

OFFICER FOR REVIEW PRIOR TO CONSTRUCTION. CONCRETE MIX DESIGN

WHERE MIX IS USED. MIX DESIGN SHALL BE SUBMITTED TO CONTRACTING

CONCRETE MIX DESIGN SUBMITTAL SHALL STATE LOCATION OF STRUCTURE 4.

4,000 PSIMISC CONCRETE

3,000 PSIFOUNDATIONS, CURBS & SLAB ON GRADE

4,000 PSICOLUMNS

SCHEDULE OF STRUCTURAL CONCRETE 28-DAY STRENGTH AND TYPES:3.

CONTRACTING OFFICER FOR REVIEW.

QUALIFIED TESTING LABORATORY AND SHALL BE SUBMITTED TO THE

ASTM C-150 TYPE I OR II. CONCRETE MIXES SHALL BE DESIGNED BY A

HARD ROCK TYPE (150#/CU. FT.) PORTLAND CEMENT SHALL CONFORM TO

ALL CONCRETE UNLESS OTHERWISE NOTED SHALL BE NORMAL WEIGHT 2.

CONCRETE WORK SHALL BE IN ACCORDANCE WITH ACI 301, UON.1.

CONCRETE

UNTIL PERMANENT STRUCTURAL FRAMING IS INSTALLED.

CONTRACTOR SHALL PROVIDE BRACING/SHORING OF CMU CONSTRUCTION 11.

TYPE.

FOR SURFACE TEXTURE AND HEIGHT OF UNITS, LAYING PATTERN AND JOINT

CONVENTIONAL RUNNING BOND. REFER TO ARCHITECTURAL DRAWINGS

UNLESS NOTED OTHERWISE, ALL WALLS SHALL BE CONSTRUCTED IN 10.

SETTING BLOCKS.

CONCRETE SURFACES SHALL BE CLEANED OF ALL LAITANCE PRIOR TO 9.

VERT. BARS WITH POSITIONERS AT 8'-0" MAX.

SET TO ALIGN WITH CORES CONTAINING REINFORCING STEEL. SECURE

CELL SHALL BE IN VERTICAL ALIGNMENT. DOWELS IN FOOTING SHALL BE 8.

PROVIDE CLEANOUT AT BASE FOR CELL CONTAINING REINFORCING.

IF BLOCK IS LAYED TO A HEIGHT EXCEEDING 5'-4" FOR EACH GROUT LIFT, 7.

GROUT SOLID ALL CELLS IN CONCRETE BLOCKS.6.

MASONRY UNITS.

PROVIDE A MINIMUM OF 1/2" GROUT BETWEEN MAIN REINFORCING AND 5.

REQUIREMENTS.

REINFORCING BARS - SEE NOTE UNDER REINFORCING STEEL FOR 4.

SEGREGATION. COMPRESSIVE STRENGTH AT 28 DAYS = 3,000 PSI.

GROUT SHALL FLOW INTO ALL JOINTS OF THE MASONRY WITHOUT 3.

ATTAIN COMPRESSIVE STRENGTH OF 1,800 PSI AT 28 DAYS.

ALL WALLS SHALL BE CONSTRUCTED WITH TYPE S MORTAR. MORTAR SHALL 2.

UNIT CONFORMING TO ASTM C 90, NORMAL WEIGHT, f'm = 1,500 PSI.

CONCRETE BLOCK SHALL BE HOLLOW LOAD-BEARING CONCRETE MASONRY 1.

CONCRETE MASONRY (CMU)

ENGINEER'S SHORING DESIGN AS REQUIRED FOR INFORMATION ONLY.

BE PROVIDED AND INSTALLED BY THE CONTRACTOR. SUBMIT STRUCTURAL

PROPERTY FREE FROM THE DAMAGE RESULTING FROM THE WORK, SHALL

THE EXCAVATIONS, EARTH BANKS AND ADJACENT STRUCTURES AND

SHORING, SHEETING, CRIBBING AND LAGGING, AS REQUIRED TO PRESERVE 15.

TO EM 385-1-1 SAFETY AND HEALTH REQUIREMENTS MANUAL.

CONTRACTOR AGAINST DANGER TO LIFE, LIMB AND PROPERTY. CONFORM

ALL EXCAVATIONS SHALL BE PROTECTED AND GUARDED BY THE 14.

BACKFILL UNTIL CONCRETE WALL HAS ATTAINED FULL DESIGN STRENGTH.

FOR RETAINING WALLS WITH BACKFILL ON ONE SIDE, DO NOT PLACE 13.

BACKFILL MATERIAL SHALL CONSIST OF NON-EXPANSIVE GRANULAR SOIL.12.

COMPACTION.

BACKFILL SHALL BE COMPACTED BETWEEN 90 AND 95 PERCENT RELATIVE

FACILITATE COMPACTION OF THE BACKFILL USING HAND EQUIPMENT.

WALL) SHALL BE LIMITED TO A MAXIMUM PARTICLE SIZE OF 1-1/2 INCHES TO

BACKFILL BEHIND RETAINING WALLS (WITHIN 40 INCHES OF THE BACK OF 11.

DENSITY AS DETERMINED BY ASTM D 1557.

COMPACTION EQUAL TO OR BETTER THAN 95 PERCENT OF MAXIMUM

WHICH SHALL BE COMPACTED AT OPTIMUM MOISTURE CONTENT TO

FILL SHALL BE PLACED IN SUCCESSIVE LOOSE LAYERS 6 INCHES DEEP 10.

LAYERS BY PNEUMATIC TAMPER INTO A DENSE MASS.

BACKFILL AROUND FOOTINGS AND FOUNDATIONS SHALL BE COMPACTED IN 9.

ASTM C33, NO. 67 GRADATION.

USING A VIBRATORY COMPACTOR. CUSHION LAYER SHALL CONFORM TO

CUSHION LAYER OF CLEAN GRAVEL AND COMPACT TO A LEVEL SURFACE

UNLESS OTHERWISE NOTED, FOR FILL UNDER SLAB ON GRADE, USE A 4 INCH 8.

ARE FOUND AND GROUTING IS REQUIRED.

PSI). CONTRACTOR SHALL PROVIDE UNIT PRICE PER CUBIC YARD IF VOIDS

FOOTING). IF VOIDS ARE FOUND, FILL VOID WITH LEAN CONCRETE (f'c = 1,500

GREATER (FOR EXAMPLE, MINIMUM 24'-0" DEEP PROBE AT 12'-0" WIDE

MINIMUM DEPTH OF 2 TIMES THE FOOTING WIDTH OR 10 FEET WHICHEVER IS

FOOTING AND EVERY 20 FEET OF WALL FOOTING. PROBE SHALL EXTEND A

PROVIDE A MINIMUM OF ONE PROBE FOR VOIDS BELOW EACH COLUMN

VOIDS THAT MAY BE ENCOUNTERED DURING FOUNDATION CONSTRUCTION.

SPECIAL CONSIDERATION SHALL BE GIVEN TO LAVA TUBES AND OTHER

= 0.25COEFFICIENT OF FRICTION

PCF= 150LATERAL PASSIVE PRESSURE

= 75 PCF (ASSUMED)AT-REST PRESSURE

= 50 PCF (ASSUMED)ACTIVE PRESSURE

AS WIND OR SEISMIC (ASSUMED)

SHORT DURATION LOADS SUCH

= 1,500 PSF W/ 1/3 INCREASE FOR ALLOWABLE BEARING PRESSURE

FOUNDATION DESIGN PARAMETERS:3.

CONTRACTOR SHALL HIRE AND PAY FOR A GEOTECHNICAL ENGINEER.2.

CODE, TABLE 1806.2, ITEM 4.

THE FOUNDATION DESIGN IS BASED ON THE 2012 INTERNATIONAL BUILDING 1.

FOUNDATION

SHALL APPLY.

DRAWINGS AND SPECIFICATIONS, THE MORE STRINGENT REQUIREMENT

SHOULD THERE BE CONFLICTS IN THE REQUIREMENTS BETWEEN THE 13.

SUBMITTED TO CONTRACTING OFFICER WITHIN 72 HOURS.

SPECIAL INSPECTION. ALL SPECIAL INSPECTION REPORTS SHALL BE

LEAST 2 DAYS IN ADVANCE FOR WORK TO BE PERFORMED REQUIRING

SAFETY ON SITE. CONTRACTOR SHALL NOTIFY SPECIAL INSPECTOR AT

ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS AND TO PROVIDE

CONTRACTOR OF HIS RESPONSIBILITIES TO COMPLETE THE PROJECT IN

AND TESTING SERVICES. SPECIAL INSPECTION SHALL NOT RELIEVE THE

CONTRACTOR SHALL HIRE AND PAY FOR THIRD-PARTY SPECIAL INSPECTION

REQUIREDUPLIFT TIESG.

REQUIREDMASONRY (LEVEL B)F.

REQUIREDEPOXY EMBEDSE.

REQUIREDANCHOR BOLTSD.

REQUIREDHIGH-STRENGTH BOLTSC.

REQUIREDREINFORCING STEEL B.

REQUIREDCONCRETE A.

STRUCTURAL DRAWINGS.

GOVERNING PORTIONS OF THE STRUCTURAL WORK SHOWN IN THE

PROVISIONS OF SECTION 1704 OF THE 2012 INTERNATIONAL BUILDING CODE

ALL SPECIAL INSPECTION SHALL BE DONE PER IBC SPECIAL INSPECTIONS

STRUCTURAL SPECIAL INSPECTION REQUIREMENTS:12.

= BALANCED DESIGNDESIGN METHOD

= 6 DEGREESEND ROTATION LIMIT

= 7DUCTILITY RATIO LIMIT

4-010-01

PER TABLE 2-1 OF UFC

ACCORDING TO ASTM F1642

= “VERY LOW HAZARD” GLASS PERFORMANCE RATING

= 55.4 PSI-MSECFULLY REFLECTED POSITIVE IMPULSE

= 15.8 PSIPEAK REFLECTED POSITIVE PRESSURE

THAT IS NOT CONTROLLED

PARAMETERS APPLYING TO WINDOWS 50 FEET OR MORE FROM PARKING

WINDOW DYNAMIC BLAST PARAMETERS

= D SEISMIC DESIGN CATEGORY

= 0.60g D1

S = 1.00g

DS

S

= DSITE CLASS

= 0.60g

S

= 1.50g S

S

II =RISK CATEGORY

= 1.00 IMPORTANCE FACTOR

D. SEISMIC (ASCE 7-10)

= 1.5

ZT

K

= CWIND EXPOSURE

II= RISK CATEGORY

= 130 MPHBASIC WIND SPEED

C. WIND (ASCE 7-10)

FLOOR LOADS TYPICALLY SUPPORTED BY SLAB ON GRADE.

ALL LIVE LOADS REDUCIBLE, UON

= 20 PSFROOF (FLAT TO LESS THAN 4:12)

= 125 PSFINDUSTRIAL BUILDING

= 100 PSFCOMMUNITY GATHERING AREA

= 100 PSFDINING FACILITY

= 100 PSFLATRINE

= 100 PSFSHOWER

= 100 PSFGP ADMIN

= 100 PSFBARRACKS

B. LIVE LOADS

UFC 3-301-01A. GENERAL STRUCTURAL DESIGN

DESIGN CRITERIA11.

FLOORS OR ROOF.

CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED 10.

STRUCTURAL MEMBERS.

NOT SHOWN ON THE STRUCTURAL DRAWINGS, BUT WHICH ARE LOCATED IN

DRAWINGS BY OTHERS SHOW OPENINGS, POCKETS, ETC., LARGER THAN 6"

STRUCTURAL DRAWINGS. NOTIFY THE CONTRACTING OFFICER WHEN

SLABS, BEAMS, WALLS, ETC., UNLESS SPECIFICALLY DETAILED ON THE

OPENINGS, POCKETS, ETC. LARGER THAN 6" SHALL NOT BE PLACED IN

CONCRETE OR OTHERWISE INCORPORATED IN STRUCTURAL WORK

SLEEVES, ELECTRICAL CONDUITS AND OTHER ITEMS TO BE EMBEDDED IN

LOCATION OF ALL OPENINGS REQUIRED FOR DUCTS, PIPES AND ALL PIPE

SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR SIZE AND 9.

AND WALL OPENINGS, FLOOR FINISHES, ETC.

SEE ARCHITECTURAL DRAWINGS FOR SIZE AND LOCATION OF ALL FLOOR 8.

SHOP DRAWINGS WILL BE REJECTED.

PHOTOCOPIES OR DUPLICATES OF CONTRACT DOCUMENTS SUBMITTED AS

TO THE CONTRACTING OFFICER FOR REVIEW PRIOR TO FABRICATION.

SHOP DRAWINGS REQUIRED BY THE SPECIFICATIONS SHALL BE SUBMITTED 7.

DIMENSIONS.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL 6.

GENERAL NOTES AND TYPICAL DETAILS.

NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER 5.

PROCEEDING WITH THE WORK.

ATTENTION OF THE CONTRACTING OFFICER AND BE RESOLVED BEFORE

EXISTING STRUCTURES. ALL DISCREPANCIES SHALL BE CALLED TO THE

THE WORK OF ALL TRADES AND SHALL CHECK ALL DIMENSIONS INCLUDING

THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR COORDINATING 4.

PROPERTY AND UTILITIES.

PROCEDURES INCLUDING LAGGING, SHORING AND PROTECTION OF

THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXCAVATION 3.

RESPONSIBILITIES.

NOR RELIEVE THE CONTRACTOR OF HIS/HER OBLIGATIONS, DUTIES AND

GOVERNMENT'S A/E SHALL NOT INCLUDE INSPECTION OF THE ABOVE ITEMS

OBSERVATION VISITS TO THE SITE BY THE CONTRACTING OFFICER AND

STRUCTURAL ENGINEER HIRED AND PAID FOR BY THE CONTRACTOR.

SHORING AND BRACING SYSTEMS SHALL BE DESIGNED BY A LICENSED

DUE TO CONSTRUCTION EQUIPMENT, WIND AND SEISMIC LOADING. ALL

SHALL INCLUDE, BUT NOT BE LIMITED TO BRACING, SHORING FOR LOADS

PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES

SHALL BE RESPONSIBLE FOR AND PROVIDE ALL MEASURES NECESSARY TO

DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR

THE STRUCTURAL DRAWINGS REPRESENT THE FINISHED STRUCTURE AND 2.

AND SPECIFICATIONS.

ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE DRAWINGS 1.

GENERAL

PERCENT RELATIVE COMPACTION.

ABOVE THE OPTIMUM MOISTURE CONTENT AND COMPACTED TO AT LEAST 95

EXCEEDING 6 INCHES IN LOOSE THICKNESS, MOISTURE-CONDITIONED TO

STRUCTURAL FILL MATERIALS SHOULD BE PLACED IN LEVEL LIFTS NOT 7.

A WELL-GRADED MATERIAL.

TO PROVIDE THE REQUIRED GRADATION AND PARTICLE SIZES TO DEVELOP

LARGE-SIZED ROCK FRAGMENTS OR BOULDERS SHOULD BE CONSIDERED

TO PRODUCE A WELL-GRADED MATERIAL, OFF-SITE CRUSHING OF

IF THE EXCAVATED ON-SITE MATERIALS DO NOT CONTAIN SUFFICIENT FINES 6.

REQUIREMENTS.

PROCESSED TO MEET MAXIMUM PARTICLE SIZE AND GRADATION

STRUCTURAL FILL MATERIALS, PROVIDED THAT THE MATERIALS ARE

EXCAVATED ON-SITE MATERIALS MAY BE RE-USED AS A SOURCE OF

PREVENT THE OCCURRENCE OF VOIDS IN THE COMPACTED MASS. THE

MATERIALS 1-1/2 INCHES IN LARGEST DIMENSION WITH SUFFICIENT FINES TO

STRUCTURAL FILL MATERIALS SHALL CONSIST OF WELL-GRADE GRANULAR 5.

STRUCTURAL FILL AS REQUIRED.

MATERIAL, INCLUDING ASH AND ORGANICS AND REPLACE WITH COMPACTED

CONTRACTOR'S GEOTECHNICAL ENGINEER. REMOVE UNSATISFACTORY

SHALL BE NOTIFIED. FOOTINGS MAY BE ALTERED AS REQUIRED BY THE

EXPECTED CONDITIONS, THE CONTRACTOR'S GEOTECHNICAL ENGINEER

SOIL ENCOUNTERED AT THESE DEPTHS APPEAR UNSTABLE AND VARY FROM

FOOTINGS SHALL BE PLACED ON UNDISTURBED EXISTING SOIL. SHOULD 4.

AREA OF WORK AS NECESSARY.

DRAWINGS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS IN

ALL EXISTING BUILDING DIMENSIONS ARE BASED ON AVAILABLE EXISTING 5.

CONCRETE AND CMU WALLS AND SLABS.

NEW PIPES AND CONDUITS SHALL NOT BE EMBEDDED IN EXISTING 4.

NEW OPENINGS IN EXISTING SLABS AND WALLS SHALL NOT BE OVERCUT.3.

TO THE CONTRACTING OFFICERS'S ATTENTION PRIOR TO STARTING WORK.

STARTING WORK. ANY DISCREPANCIES WITH DRAWINGS SHALL BE BROUGHT

DIMENSIONS SHALL BE VERIFIED BY CONTRACTOR IN FIELD PRIOR TO

SEE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. ALL EXISTING 2.

DEMOLITION WORK.

CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AND BRACING FOR ALL 1.

DEMOLITION NOTES

REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.4.

FIBER WRAP SYSTEM SHALL CONFORM TO ACI 440.2R.3.

AS A MINIMUM.

LOCATIONS AND FORCE DEMANDS THAT FIBER WRAP SYSTEM MUST RESIST

STRUCTURAL DRAWINGS BY NAGAMINE OKAWA ENGINEERS INC. PROVIDE 2.

FOR REVIEW AND COMMENT.

WRAP DESIGN ENGINEER SHALL BE PROVIDED TO CONTRACTING OFFICER

CALCULATIONS AND SHOP DRAWINGS STAMPED AND SIGNED BY FIBER

AND SHALL BE DESIGNED BY A LICENSED STRUCTURAL ENGINEER.

FIBER WRAP STRENGTHENING SHALL BE PROVIDED BY THE CONTRACTOR 1.

FIBER WRAP STRENGTHENING

SUSPENDED CEILINGS, MECHANICAL DUCTS, PIPING, ETC.

METAL DECKING WITHOUT TOPPING SHALL NOT BE USED TO SUPPORT 12.

ALL WELDS SHALL HAVE TOUCH-UP.

MANUFACTURER'S RECOMMENDATIONS. UPON COMPLETION OF ERECTION,

INDICATED ON THE DRAWINGS AND IN ACCORDANCE WITH

BE ATTACHED TO ALL SUPPORTING STEEL MEMBERS BY WELDING AS

MINIMUM BEARING OF DECKING ON SUPPORTS SHALL BE 2". SHEETS SHALL 11.

SHALL SPAN OVER THREE OR MORE SUPPORTS.

PROTECTIVE COATING OF ZINC (G60). SEE SPECIFICATIONS. DECK UNITS

CONFORMING TO ASTM A446, GRADE A. THE STEEL SHALL HAVE A METAL

STEEL SHEETS HAVING A MINIMUM YIELD STRENGTH OF 33,000 PSI AND

THE DRAWINGS. DECKING AND ALL ACCESSORIES SHALL BE FORMED FROM

THE STEEL DECKING SHALL BE OF THE TYPE AND GAUGE AS CALLED FOR ON 10.

5,000 PSI. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.

CONCRETE WALLS, ETC., SHALL BE NON-SHRINK, NON-STAINING, WITH f'c =

ALL GROUT (OR DRYPACK) BELOW BASE PLATES, BEAMS BEARING ON 9.

COATED WITH TWO COATS OF ZINC RICH PRIMER.

ASTM A123 OR A153. ALL WELDS AFTER HOT DIP GALVANIZING SHALL BE

HOT DIP GALVANIZED STEEL REFERENCED ON PLAN SHALL CONFORM TO 8.

SPECIFICATIONS.

CODE AWS D1.1-04 OF THE AMERICAN WELDING SOCIETY; SEE

ALL WELDS SHALL BE IN CONFORMITY WITH THE STRUCTURAL WELDING 7.

MASONRY SHALL BE CLEAN AND LEFT UNPAINTED.

ALL STRUCTURAL STEEL SURFACES THAT ARE ENCASED IN CONCRETE OR 6.

SIZE OF BOLT USED, UNLESS OTHERWISE NOTED.

BOLT HOLES IN STEEL SHALL BE 1/16" LARGER DIAMETER THAN NOMINAL 5.

REVIEW BEFORE FABRICATION.

ALL STRUCTURAL STEEL RESPECTIVELY, FOR CONTRACTING OFFICER'S

THE STRUCTURAL STEEL FABRICATOR SHALL FURNISH SHOP DRAWINGS OF 4.

GALVANIZED.

RODS EPOXY EMBEDDED SHALL CONFORM TO ASTM A36 AND BE HOT DIP

CONFORMING TO ASTM A325 OR A490. UNLESS OTHERWISE NOTED, ANCHOR

UNLESS OTHERWISE NOTED. USE ALTERNATIVE DESIGN FASTENER

ALL BOLTS SHALL CONFORM TO ASTM A325N HIGH STRENGTH BOLTS, 3.

= A500, GRADE BTUBES

= A500, GRADE BPIPES

= A36PLATES, MISC. STEEL

CHANNELS, ANGLES, TEES,

= A992, GRADE 50WIDE FLANGES

DESIGNATIONS:

STRUCTURAL STEEL SECTIONS SHALL CONFORM TO THE FOLLOWING ASTM 2.

FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS."

ACCORDANCE WITH THE "AISC SPECIFICATION FOR THE DESIGN,

STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN 1.

STRUCTURAL STEEL

STEEL" OF THE AMERICAN WELDING SOCIETY.

CONFORM TO AWS D1.4 "AWS STRUCTURAL WELDING CODE - REINFORCING

SHOWN ON THE DRAWINGS. WELDING OF REINFORCING STEEL SHALL

WELDING OF REINFORCING STEEL IS NOT PERMITTED UNLESS OTHERWISE 8.

FROM REVIEWED DRAWINGS ONLY.

CONTRACTING OFFICER'S REVIEW PRIOR TO FABRICATION. FABRICATE

CONTRACTOR SHALL SUBMIT REINFORCING BAR LAYOUTS AND DETAILS FOR 7.

MODIFIED BY THE PROJECT DRAWINGS AND SPECIFICATIONS.

CONFORMANCE WITH THE "ACI DETAILING MANUAL - 2004" (SP-66) AS

ALL REINFORCING STEEL SHALL BE DETAILED AND PLACED IN 6.

ALL REINFORCING BAR BENDS SHALL BE MADE COLD.5.

SECURELY TIED IN PLACE BEFORE CONCRETE IS POURED.

ANCHOR BOLTS, DOWELS AND OTHER EMBEDDED ITEMS ARE TO BE 4.

DRAWINGS.

REINFORCING SPLICES SHALL BE MADE ONLY WHERE INDICATED ON THE 3.

U.O.N.

AND SPACING OR NUMBERS AS THE VERTICAL REINFORCING RESPECTIVELY,

DOWELS BETWEEN FOOTING AND WALL SHALL BE THE SAME GRADE, SIZE 2.

REQUIREMENTS OR ASTM A706 WHERE WELDING IS REQUIRED.

REINFORCING BARS SHALL CONFORM TO ASTM A-615 GRADE 60 1.

REINFORCING STEEL

AMPLITUDE OF 1/4".

ALL ROUGHENED SURFACES IN CONCRETE SHALL BE MADE WITH A MINIMUM 11.

SHALL NOT BE USED.

CONCRETE ADMIXTURES CONTAINING CHLORIDE OR CHLORIDE SALTS 10.

SPECIFYING CONCRETE POURS IN UPCOMING THREE WEEKS.

CONTRACTOR SHALL PROVIDE THE CONTRACTING OFFICER A SCHEDULE 9.

BEFORE USE.

ARCHITECTURAL FINISH SHALL BE APPROVED BY THE FINISH SUPPLIER

CURING COMPOUNDS USED ON CONCRETE THAT IS TO RECEIVE AN 8.

SHOWN ON THE DRAWINGS.

NOTIFY THE CONTRACTING OFFICER IN ADVANCE OF CONDITIONS NOT

CONFLICT. CORING IN CONCRETE IS NOT PERMITTED EXCEPT AS SHOWN.

CONCRETE BEFORE PLACING. DO NOT CUT ANY REINFORCING WHICH MAY

PROVIDE SLEEVES FOR PLUMBING AND ELECTRICAL OPENINGS IN 7.

SHALL BE WELL SECURED IN POSITION PRIOR TO PLACING CONCRETE.

ALL REINFORCING BARS, ANCHOR BOLTS AND OTHER CONCRETE INSERTS 6.

2" CLEAR TO STIRRUPS AND TIESBEAMS AND COLUMNSD.

1" CLEAR TO REINFORCINGWALLSC.

BE AS FOLLOWS (U.O.N.):

CLEAR COVERAGE OF CONCRETE OVER OUTER REINFORCING BARS SHALL 5.

PROJECT SITE.

SHALL ACCOUNT FOR TRAVEL TIME AND TEMPERATURE CONDITIONS AT THE

OFFICER FOR REVIEW PRIOR TO CONSTRUCTION. CONCRETE MIX DESIGN

WHERE MIX IS USED. MIX DESIGN SHALL BE SUBMITTED TO CONTRACTING

CONCRETE MIX DESIGN SUBMITTAL SHALL STATE LOCATION OF STRUCTURE 4.

4,000 PSIMISC CONCRETE

3,000 PSIFOUNDATIONS, CURBS & SLAB ON GRADE

4,000 PSICOLUMNS

SCHEDULE OF STRUCTURAL CONCRETE 28-DAY STRENGTH AND TYPES:3.

CONTRACTING OFFICER FOR REVIEW.

QUALIFIED TESTING LABORATORY AND SHALL BE SUBMITTED TO THE

ASTM C-150 TYPE I OR II. CONCRETE MIXES SHALL BE DESIGNED BY A

HARD ROCK TYPE (150#/CU. FT.) PORTLAND CEMENT SHALL CONFORM TO

ALL CONCRETE UNLESS OTHERWISE NOTED SHALL BE NORMAL WEIGHT 2.

CONCRETE WORK SHALL BE IN ACCORDANCE WITH ACI 301, UON.1.

CONCRETE

UNTIL PERMANENT STRUCTURAL FRAMING IS INSTALLED.

CONTRACTOR SHALL PROVIDE BRACING/SHORING OF CMU CONSTRUCTION 11.

TYPE.

FOR SURFACE TEXTURE AND HEIGHT OF UNITS, LAYING PATTERN AND JOINT

CONVENTIONAL RUNNING BOND. REFER TO ARCHITECTURAL DRAWINGS

UNLESS NOTED OTHERWISE, ALL WALLS SHALL BE CONSTRUCTED IN 10.

SETTING BLOCKS.

CONCRETE SURFACES SHALL BE CLEANED OF ALL LAITANCE PRIOR TO 9.

VERT. BARS WITH POSITIONERS AT 8'-0" MAX.

SET TO ALIGN WITH CORES CONTAINING REINFORCING STEEL. SECURE

CELL SHALL BE IN VERTICAL ALIGNMENT. DOWELS IN FOOTING SHALL BE 8.

PROVIDE CLEANOUT AT BASE FOR CELL CONTAINING REINFORCING.

IF BLOCK IS LAYED TO A HEIGHT EXCEEDING 5'-4" FOR EACH GROUT LIFT, 7.

GROUT SOLID ALL CELLS IN CONCRETE BLOCKS.6.

MASONRY UNITS.

PROVIDE A MINIMUM OF 1/2" GROUT BETWEEN MAIN REINFORCING AND 5.

REQUIREMENTS.

REINFORCING BARS - SEE NOTE UNDER REINFORCING STEEL FOR 4.

SEGREGATION. COMPRESSIVE STRENGTH AT 28 DAYS = 3,000 PSI.

GROUT SHALL FLOW INTO ALL JOINTS OF THE MASONRY WITHOUT 3.

ATTAIN COMPRESSIVE STRENGTH OF 1,800 PSI AT 28 DAYS.

ALL WALLS SHALL BE CONSTRUCTED WITH TYPE S MORTAR. MORTAR SHALL 2.

UNIT CONFORMING TO ASTM C 90, NORMAL WEIGHT, f'm = 1,500 PSI.

CONCRETE BLOCK SHALL BE HOLLOW LOAD-BEARING CONCRETE MASONRY 1.

CO…