This pre-solicitation notice concerns a firm-fixed price initial outfitting and transition supply contract for the Medical Center Addition and Alteration project at the Walter Reed National Military Medical Center in Bethesda, Maryland. The contract is a Service-Disabled Veteran Owned Small Business set-aside to be administered by the United States Army Corps of Engineers Engineering District in Little Rock. The project involves renovations and additions totaling 124,050 gross square feet to currently occupied spaces, demolition of 332,000 gross square feet of aging buildings, and construction of 590,000 gross square feet of new medical services facilities in two phases. Transition and outfitting services will be required for the renovated and new buildings, including relocation of equipment and personnel, excess property disposal, and commissioning. The anticipated period of performance is approximately 1,870 days from award. The pre-solicitation notice provides details on the scope of work for each building. The solicitation is expected to be posted on February 1, 2022 but timelines remain subject to change.
View the file
Other files
Show 40 more
Latest 50 of 90 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D
C
B
20 21
AA
BB
CC
DD
PRESENTATION
SERVICES
STORAGE/
STAGING
BB11
SRS01
CORRIDOR BC
BB07
Z9101
PRESENTATION
SERVICES
CUBICLE
BB12A
OFA03
PRESENTATION
SERVICES
CUBICLE
BB12B
OFA03
PRESENTATION
SERVICES
CUBICLE
BB12C
OFA03
CORRIDOR BC
BB04
Z9101
CUBICLE
CORRIDOR
BB06
Z9101
PRESENTATION
SERVICES
CUBICLE
BB12D
OFA03
COPY/ PRINT
AREA
BB15
RPR01
F0250-B
F0740M1 A6046 F2420
F3200
MATCHLINE IF-10B-E2MATCHLINE IF-10B-E1
MATCHLINE IF-10B-B4
MATCHLINE IF-10B-B4
F2000
F0250-B
GREEN
ADMINISTRATIVE
OFFICE
BB21
ZDR01
F0275F0415
E0084M1
F0275
F0275
E0084M1
F0420
F0420
F0415
F0415
F0415
F2026
F0102
U5007
F0465
E0084M1
MATCHLINE IF-10B-E1
F0375M-I
F0250-BF0250-B
F0740M1 F0740M1
F2420M1 F2420M1
F2000 F2025
F2025
F2000
F2025
F2000
CORRIDOR BC
BB03
Z9101
ARCHIVEARCHIVE
BB14
MIST1
FURNITURE GENERAL NOTES
1. FURNITURE OVER 48" HIGH IS REQUIRED TO BE SEISMICALLY ANCHORED. THIS
WILL INCLUDE, BUT IS NOT LIMITED TO: FILE CABINETS, SHELVING UNITS,
BOOKCASES, AND MODULAR WORK STATION PANELS.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL PRODUCT
SPECIFIC ANCHORAGE DETAILS WITH THE FURNITURE MANUFACTURER.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE LOCATION
OF ALL REQUIRED WALL BACKING AND FLOOR ANCHORS WITH THE
FURNITURE MANUFACTURER.
4. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE STAMPED AND
SIGNED BY A LICENSED STRUCTURAL ENGINEER AUTHORIZED TO WORK BY
THE AGENCY HAVING JURISDICTION.
5. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE REVIEWED AND
APPROVED BY THE AGENCY HAVING JURISDICTION.
6. REFER TO BUILDING ELECTRICAL POWER AND DATA PLANS TO COORDINATE
SYSTEMS AND OTHER FURNITURE WHIP CONNECTIONS. FINAL LOCATIONS OF
FLOOR MOUNTED RECEPTACLES SHALL BE COORDINATED WITH FINAL
FURNITURE SELECTIONS.
7. THE SYSTEMS FURNITURE VENDOR IS RESPONSIBLE FOR PROVIDING POWER
WHIPS AND CONNECTING THEM BY A LICENSED ELECTRICIAN.
8. FURNITURE SYSTEMS VENDOR'S INSTALLATIONS SHALL NOT BE CONSIDERED
COMPLETE UNTIL ALL LAMPS AND ELECTRICAL OUTLETS OPERATE.
9. MANUFACTURER/FURNITURE VENDOR SHALL FIELD VERIFY DIMENSIONS
PRIOR TO PLACING FURNITURE ORDERS AND ARE RESPONSIBLE FOR
COORDINATING CHANGES DUE TO CONFLICTS WITH FIELD CONDITIONS.
VENDOR SHALL COORDINATE HANDED WORKSTATION AND PRIVATE OFFICE
FURNITURE LAYOUTS.
10. REFER TO FURNITURE ILLUSTRATION SHEETS FOR MORE INFORMATION.
FURNITURE CLARIFICATION NOTES
1. THE IF SERIES FURNITURE PLANS ARE FOR USE WITH THE COMPREHENSIVE
INTERIOR DESIGN (CID) PACKAGE FOR FURNITURE PLACEMENT AND
PROCUREMENT.
2. THE IF PLANS SHOW ALL ITEMS INCLUDED IN THE CID PACKAGE AS DASHED AND
TAGGED WITH RESPECTIVE JOINT SCHEDULE NUMBER (JSN) CODES.
3. EQUIPMENT ITEMS NOT INCLUDED IN THE CID PACKAGE ARE SHOWN DASHED AND
WITHOUT JSN CODES. THESE ITEMS ARE SHOWN ON THE IF PLANS FOR
COORDINATION AND SPATIAL RELATIONSHIP ONLY.
4. FOR PLANS NOTING JSN CODES FOR ALL LOGCAT EQUIPMENT ITEMS, REFER TO
THE Q-SERIES EQUIPMENT PLANS.
5. FURNITURE DEALER IS RESPONSIBLE FOR FIELD MEASURING PRIOR TO PLACING
ANY ORDER.
6. DESKS AND WALL MONITORS IN SOLID GREY OUTLINE ARE SHOWN FOR
COORDINATION PURPOSES ONLY AND ARE NOT IN CID PACKAGE. FOR ADDITIONAL
INFORMATION REFER TO TV STUDIO SECTION IN DRAWINGS AND SPECIFICATIONS
APPENDICES.
C
D
B
A
ARCHITECTURE | ENGINEERING
& CONSULTING
3001 WASHINGTON BLVD.
SUITE 200
ARLINGTON, VIRGINIA 22201
703-518-8500
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
NAVFAC DRAWING NO.
ePROJECT NO.:
SCALE:
SHEET OF
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
C
D
B
A
4321 5
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW REV
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
FIRE PROTECTION
As indicated
C rv t\
\A R
-1
-A
-F P
-C -P
-B
J O
S W
A L
D .r v t
/8
/2
:0
:1
P
M
IF-10B-B3
B A
S E
M E
N T
F U
R N
IT
U
R E
P L A
N
A R
E A
B
P H
A S
E
13090146
1171746
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N
A V
F A
C W
A S
H
IN
G T
O N
A T
L A
N T
IC
W
R N
M M
C
B e th e s d a
M
D
N S
A /B e th e s d a M
D B
E T
H E
S D
A M
D
P M
E D
IC
A
L C
E N
T E
R A
D D
IT
IO
N A
L T
E R
A T
IO
N
ROBSON/NOURI
NORTH
P1 Q1 R1 R2
Q2 R4
L2 M4 N3 N4M3
L1 M2 N1 N2M1
H2 J4 K3 K4J3
H1 J2 K1 K2J1
E4 F4 G3 G4F3E3
E2 F2 G1 G2F1E1
B4 C2 D1 D2C1B3
B2B1
A2
A1
KEY PLAN
P H
A S
E
P H
A S
E
D3
Z
R3
1/4" = 1'-0"
FURNITURE PLAN LEVEL B - AREA B3 - PHASE 1
0 2'-0" 4'-0" 8'-0"
SYM DESCRIPTION DATE
EBS SUBMISSION 02/28/18
UP
D
C
B
21 22
CC
DD
AVP
EQUIPMENT
STORAGE/
STAGING
BB13
SRS01
CORRIDOR BC
BB03
Z9101
EDIT
BF12
MIST1
CORRIDOR BC
BB04
Z9101
CORRIDOR BC
BB05
Z9101
F3200
STAIR 1
BBST
Z9102
MATCHLINE IF-10B-E2MATCHLINE IF-10B-E1
MATCHLINE IF-10B-B3
MATCHLINE IF-10B-F1MATCHLINE IF-10B-E2
MATCHLINE IF-10B-C1
MATCHLINE IF-10B-B3 MATCHLINE IF-10B-C1
F2010
F2000
GREEN
ADMINISTRATIVE
OFFICE
BB21
ZDR01
F0375M-I
F0250-BF0250-B
F0740M1 F0740M1
F2420M1 F2420M1
A6046
F2010
PASSENGER
ELEVATOR P7
4000 LB
BBESW
Z9103
PATIENT
TRANSPORT
ELEVATOR H1
6000 LB
BBESE
Z9103
F3200
F3200
F2025F2000
TV STUDIOTV STUDIO
BB18
MIST1
ARCHIVEARCHIVE
BB14
MIST1
M PUB TLTM PUB TLT
BB20
TLTM2
CORR BCCORR BC
BB02
Z9101
FURNITURE GENERAL NOTES
1. FURNITURE OVER 48" HIGH IS REQUIRED TO BE SEISMICALLY ANCHORED. THIS
WILL INCLUDE, BUT IS NOT LIMITED TO: FILE CABINETS, SHELVING UNITS,
BOOKCASES, AND MODULAR WORK STATION PANELS.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL PRODUCT
SPECIFIC ANCHORAGE DETAILS WITH THE FURNITURE MANUFACTURER.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE LOCATION
OF ALL REQUIRED WALL BACKING AND FLOOR ANCHORS WITH THE
FURNITURE MANUFACTURER.
4. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE STAMPED AND
SIGNED BY A LICENSED STRUCTURAL ENGINEER AUTHORIZED TO WORK BY
THE AGENCY HAVING JURISDICTION.
5. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE REVIEWED AND
APPROVED BY THE AGENCY HAVING JURISDICTION.
6. REFER TO BUILDING ELECTRICAL POWER AND DATA PLANS TO COORDINATE
SYSTEMS AND OTHER FURNITURE WHIP CONNECTIONS. FINAL LOCATIONS OF
FLOOR MOUNTED RECEPTACLES SHALL BE COORDINATED WITH FINAL
FURNITURE SELECTIONS.
7. THE SYSTEMS FURNITURE VENDOR IS RESPONSIBLE FOR PROVIDING POWER
WHIPS AND CONNECTING THEM BY A LICENSED ELECTRICIAN.
8. FURNITURE SYSTEMS VENDOR'S INSTALLATIONS SHALL NOT BE CONSIDERED
COMPLETE UNTIL ALL LAMPS AND ELECTRICAL OUTLETS OPERATE.
9. MANUFACTURER/FURNITURE VENDOR SHALL FIELD VERIFY DIMENSIONS
PRIOR TO PLACING FURNITURE ORDERS AND ARE RESPONSIBLE FOR
COORDINATING CHANGES DUE TO CONFLICTS WITH FIELD CONDITIONS.
VENDOR SHALL COORDINATE HANDED WORKSTATION AND PRIVATE OFFICE
FURNITURE LAYOUTS.
10. REFER TO FURNITURE ILLUSTRATION SHEETS FOR MORE INFORMATION.
FURNITURE CLARIFICATION NOTES
1. THE IF SERIES FURNITURE PLANS ARE FOR USE WITH THE COMPREHENSIVE
INTERIOR DESIGN (CID) PACKAGE FOR FURNITURE PLACEMENT AND
PROCUREMENT.
2. THE IF PLANS SHOW ALL ITEMS INCLUDED IN THE CID PACKAGE AS DASHED AND
TAGGED WITH RESPECTIVE JOINT SCHEDULE NUMBER (JSN) CODES.
3. EQUIPMENT ITEMS NOT INCLUDED IN THE CID PACKAGE ARE SHOWN DASHED AND
WITHOUT JSN CODES. THESE ITEMS ARE SHOWN ON THE IF PLANS FOR
COORDINATION AND SPATIAL RELATIONSHIP ONLY.
4. FOR PLANS NOTING JSN CODES FOR ALL LOGCAT EQUIPMENT ITEMS, REFER TO
THE Q-SERIES EQUIPMENT PLANS.
5. FURNITURE DEALER IS RESPONSIBLE FOR FIELD MEASURING PRIOR TO PLACING
ANY ORDER.
6. DESKS AND WALL MONITORS IN SOLID GREY OUTLINE ARE SHOWN FOR
COORDINATION PURPOSES ONLY AND ARE NOT IN CID PACKAGE. FOR ADDITIONAL
INFORMATION REFER TO TV STUDIO SECTION IN DRAWINGS AND SPECIFICATIONS
APPENDICES.
C
D
B
A
ARCHITECTURE | ENGINEERING
& CONSULTING
3001 WASHINGTON BLVD.
SUITE 200
ARLINGTON, VIRGINIA 22201
703-518-8500
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
NAVFAC DRAWING NO.
ePROJECT NO.:
SCALE:
SHEET OF
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
C
D
B
A
4321 5
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW REV
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
FIRE PROTECTION
As indicated
C rv t\
\A R
-1
-A
-F P
-C -P
-B
J O
S W
A L
D .r v t
/8
/2
:0
:2
P
M
IF-10B-B4
B A
S E
M E
N T
F U
R N
IT
U
R E
P L A
N
A R
E A
B
P H
A S
E
13090147
1171746
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N
A V
F A
C W
A S
H
IN
G T
O N
A T
L A
N T
IC
W
R N
M M
C
B e th e s d a
M
D
N S
A /B e th e s d a M
D B
E T
H E
S D
A M
D
P M
E D
IC
A
L C
E N
T E
R A
D D
IT
IO
N A
L T
E R
A T
IO
N
ROBSON/NOURI
NORTH
P1 Q1 R1 R2
Q2 R4
L2 M4 N3 N4M3
L1 M2 N1 N2M1
H2 J4 K3 K4J3
H1 J2 K1 K2J1
E4 F4 G3 G4F3E3
E2 F2 G1 G2F1E1
B4 C2 D1 D2C1B3
B2B1
A2
A1
KEY PLAN
P H
A S
E
P H
A S
E
D3
Z
R3
1/4" = 1'-0"
FURNITURE PLAN LEVEL B - AREA B4 - PHASE 1
0 2'-0" 4'-0" 8'-0"
C
B
EDIT
BF15
MIST1
EDIT
BF12
MIST1
E0099M E0099M
F0275F0275
CORRIDOR BC
BC01
Z9101
MATCHLINE IF-10B-F1MATCHLINE IF-10B-E2
MATCHLINE IF-10B-B4
MATCHLINE IF-10B-F2MATCHLINE IF-10B-F1
MATCHLINE IF-10B-C2
MATCHLINE IF-10B-B4 MATCHLINE IF-10B-C2
EDIT
BF13A
MIST1
HEALTH
PHYSICIST
OFFICE
BF41A
OFA03
F3200 F3200 F3200
F2025F2000
TV STUDIOTV STUDIO
BB18
MIST1
CORRIDOR BC
BB05
Z9101
FURNITURE GENERAL NOTES
1. FURNITURE OVER 48" HIGH IS REQUIRED TO BE SEISMICALLY ANCHORED. THIS
WILL INCLUDE, BUT IS NOT LIMITED TO: FILE CABINETS, SHELVING UNITS,
BOOKCASES, AND MODULAR WORK STATION PANELS.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL PRODUCT
SPECIFIC ANCHORAGE DETAILS WITH THE FURNITURE MANUFACTURER.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE LOCATION
OF ALL REQUIRED WALL BACKING AND FLOOR ANCHORS WITH THE
FURNITURE MANUFACTURER.
4. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE STAMPED AND
SIGNED BY A LICENSED STRUCTURAL ENGINEER AUTHORIZED TO WORK BY
THE AGENCY HAVING JURISDICTION.
5. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE REVIEWED AND
APPROVED BY THE AGENCY HAVING JURISDICTION.
6. REFER TO BUILDING ELECTRICAL POWER AND DATA PLANS TO COORDINATE
SYSTEMS AND OTHER FURNITURE WHIP CONNECTIONS. FINAL LOCATIONS OF
FLOOR MOUNTED RECEPTACLES SHALL BE COORDINATED WITH FINAL
FURNITURE SELECTIONS.
7. THE SYSTEMS FURNITURE VENDOR IS RESPONSIBLE FOR PROVIDING POWER
WHIPS AND CONNECTING THEM BY A LICENSED ELECTRICIAN.
8. FURNITURE SYSTEMS VENDOR'S INSTALLATIONS SHALL NOT BE CONSIDERED
COMPLETE UNTIL ALL LAMPS AND ELECTRICAL OUTLETS OPERATE.
9. MANUFACTURER/FURNITURE VENDOR SHALL FIELD VERIFY DIMENSIONS
PRIOR TO PLACING FURNITURE ORDERS AND ARE RESPONSIBLE FOR
COORDINATING CHANGES DUE TO CONFLICTS WITH FIELD CONDITIONS.
VENDOR SHALL COORDINATE HANDED WORKSTATION AND PRIVATE OFFICE
FURNITURE LAYOUTS.
10. REFER TO FURNITURE ILLUSTRATION SHEETS FOR MORE INFORMATION.
FURNITURE CLARIFICATION NOTES
1. THE IF SERIES FURNITURE PLANS ARE FOR USE WITH THE COMPREHENSIVE
INTERIOR DESIGN (CID) PACKAGE FOR FURNITURE PLACEMENT AND
PROCUREMENT.
2. THE IF PLANS SHOW ALL ITEMS INCLUDED IN THE CID PACKAGE AS DASHED AND
TAGGED WITH RESPECTIVE JOINT SCHEDULE NUMBER (JSN) CODES.
3. EQUIPMENT ITEMS NOT INCLUDED IN THE CID PACKAGE ARE SHOWN DASHED AND
WITHOUT JSN CODES. THESE ITEMS ARE SHOWN ON THE IF PLANS FOR
COORDINATION AND SPATIAL RELATIONSHIP ONLY.
4. FOR PLANS NOTING JSN CODES FOR ALL LOGCAT EQUIPMENT ITEMS, REFER TO
THE Q-SERIES EQUIPMENT PLANS.
5. FURNITURE DEALER IS RESPONSIBLE FOR FIELD MEASURING PRIOR TO PLACING
ANY ORDER.
6. DESKS AND WALL MONITORS IN SOLID GREY OUTLINE ARE SHOWN FOR
COORDINATION PURPOSES ONLY AND ARE NOT IN CID PACKAGE. FOR ADDITIONAL
INFORMATION REFER TO TV STUDIO SECTION IN DRAWINGS AND SPECIFICATIONS
APPENDICES.
C
D
B
A
ARCHITECTURE | ENGINEERING
& CONSULTING
3001 WASHINGTON BLVD.
SUITE 200
ARLINGTON, VIRGINIA 22201
703-518-8500
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
NAVFAC DRAWING NO.
ePROJECT NO.:
SCALE:
SHEET OF
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
C
D
B
A
4321 5
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW REV
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
FIRE PROTECTION
As indicated
C rv t\
\A R
-1
-A
-F P
-C -P
-B
J O
S W
A L
D .r v t
/8
/2
:0
:3
P
M
IF-10B-C1
B A
S E
M E
N T
F U
R N
IT
U
R E
P L A
N
A R
E A
C
P H
A S
E
13090148
1171746
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N
A V
F A
C W
A S
H
IN
G T
O N
A T
L A
N T
IC
W
R N
M M
C
B e th e s d a
M
D
N S
A /B e th e s d a M
D B
E T
H E
S D
A M
D
P M
E D
IC
A
L C
E N
T E
R A
D D
IT
IO
N A
L T
E R
A T
IO
N
ROBSON/NOURI
NORTH
P1 Q1 R1 R2
Q2 R4
L2 M4 N3 N4M3
L1 M2 N1 N2M1
H2 J4 K3 K4J3
H1 J2 K1 K2J1
E4 F4 G3 G4F3E3
E2 F2 G1 G2F1E1
B4 C2 D1 D2C1B3
B2B1
A2
A1
KEY PLAN
P H
A S
E
P H
A S
E
D3
Z
R3
1/4" = 1'-0"
FURNITURE PLAN LEVEL B - AREA C1 - PHASE 1
0 2'-0" 4'-0" 8'-0"
C
B
E0099M E0099M E0099M
F0275F0275F0275 F0230
F3050
F0275
F0465
F3200
F0230
CORRIDOR BC
BC01
Z9101
MATCHLINE IF-10B-F2MATCHLINE IF-10B-F1
MATCHLINE IF-10B-C1
MATCHLINE IF-10B-G1MATCHLINE IF-10B-F2
MATCHLINE IF-10B-D1
MATCHLINE IF-10B-C1 MATCHLINE IF-10B-D1
F2000F2025
MATCHLINE IF-10B-D3
SAFETY &
HLTH
SAFETY &
HLTH
BF41C
OFA03
SCIENCE
ADVISOR
SCIENCE
ADVISOR
BF42
OFM01
RAD SFTY
OFCR
RAD SFTY
OFCR
BF41B
OFA02
RESEARCH
AREA
RESEARCH
AREA
BF43
LIBS1
DOSIM LABDOSIM LAB
BF44
LBMN1
COMMUNICATIONS
ROOM
BF45
COMC1
ELECTRICAL
ROOM BC
BG11
Z9301
FURNITURE GENERAL NOTES
1. FURNITURE OVER 48" HIGH IS REQUIRED TO BE SEISMICALLY ANCHORED. THIS
WILL INCLUDE, BUT IS NOT LIMITED TO: FILE CABINETS, SHELVING UNITS,
BOOKCASES, AND MODULAR WORK STATION PANELS.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL PRODUCT
SPECIFIC ANCHORAGE DETAILS WITH THE FURNITURE MANUFACTURER.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE LOCATION
OF ALL REQUIRED WALL BACKING AND FLOOR ANCHORS WITH THE
FURNITURE MANUFACTURER.
4. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE STAMPED AND
SIGNED BY A LICENSED STRUCTURAL ENGINEER AUTHORIZED TO WORK BY
THE AGENCY HAVING JURISDICTION.
5. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE REVIEWED AND
APPROVED BY THE AGENCY HAVING JURISDICTION.
6. REFER TO BUILDING ELECTRICAL POWER AND DATA PLANS TO COORDINATE
SYSTEMS AND OTHER FURNITURE WHIP CONNECTIONS. FINAL LOCATIONS OF
FLOOR MOUNTED RECEPTACLES SHALL BE COORDINATED WITH FINAL
FURNITURE SELECTIONS.
7. THE SYSTEMS FURNITURE VENDOR IS RESPONSIBLE FOR PROVIDING POWER
WHIPS AND CONNECTING THEM BY A LICENSED ELECTRICIAN.
8. FURNITURE SYSTEMS VENDOR'S INSTALLATIONS SHALL NOT BE CONSIDERED
COMPLETE UNTIL ALL LAMPS AND ELECTRICAL OUTLETS OPERATE.
9. MANUFACTURER/FURNITURE VENDOR SHALL FIELD VERIFY DIMENSIONS
PRIOR TO PLACING FURNITURE ORDERS AND ARE RESPONSIBLE FOR
COORDINATING CHANGES DUE TO CONFLICTS WITH FIELD CONDITIONS.
VENDOR SHALL COORDINATE HANDED WORKSTATION AND PRIVATE OFFICE
FURNITURE LAYOUTS.
10. REFER TO FURNITURE ILLUSTRATION SHEETS FOR MORE INFORMATION.
FURNITURE CLARIFICATION NOTES
1. THE IF SERIES FURNITURE PLANS ARE FOR USE WITH THE COMPREHENSIVE
INTERIOR DESIGN (CID) PACKAGE FOR FURNITURE PLACEMENT AND
PROCUREMENT.
2. THE IF PLANS SHOW ALL ITEMS INCLUDED IN THE CID PACKAGE AS DASHED AND
TAGGED WITH RESPECTIVE JOINT SCHEDULE NUMBER (JSN) CODES.
3. EQUIPMENT ITEMS NOT INCLUDED IN THE CID PACKAGE ARE SHOWN DASHED AND
WITHOUT JSN CODES. THESE ITEMS ARE SHOWN ON THE IF PLANS FOR
COORDINATION AND SPATIAL RELATIONSHIP ONLY.
4. FOR PLANS NOTING JSN CODES FOR ALL LOGCAT EQUIPMENT ITEMS, REFER TO
THE Q-SERIES EQUIPMENT PLANS.
5. FURNITURE DEALER IS RESPONSIBLE FOR FIELD MEASURING PRIOR TO PLACING
ANY ORDER.
6. DESKS AND WALL MONITORS IN SOLID GREY OUTLINE ARE SHOWN FOR
COORDINATION PURPOSES ONLY AND ARE NOT IN CID PACKAGE. FOR ADDITIONAL
INFORMATION REFER TO TV STUDIO SECTION IN DRAWINGS AND SPECIFICATIONS
APPENDICES.
C
D
B
A
ARCHITECTURE | ENGINEERING
& CONSULTING
3001 WASHINGTON BLVD.
SUITE 200
ARLINGTON, VIRGINIA 22201
703-518-8500
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
NAVFAC DRAWING NO.
ePROJECT NO.:
SCALE:
SHEET OF
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
C
D
B
A
4321 5
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW REV
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
FIRE PROTECTION
As indicated
C rv t\
\A R
-1
-A
-F P
-C -P
-B
J O
S W
A L
D .r v t
/8
/2
:0
:5
P
M
IF-10B-C2
B A
S E
M E
N T
F U
R N
IT
U
R E
P L A
N
A R
E A
C
P H
A S
E
13090149
1171746
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N
A V
F A
C W
A S
H
IN
G T
O N
A T
L A
N T
IC
W
R N
M M
C
B e th e s d a
M
D
N S
A /B e th e s d a M
D B
E T
H E
S D
A M
D
P M
E D
IC
A
L C
E N
T E
R A
D D
IT
IO
N A
L T
E R
A T
IO
N
ROBSON/NOURI
NORTH
P1 Q1 R1 R2
Q2 R4
L2 M4 N3 N4M3
L1 M2 N1 N2M1
H2 J4 K3 K4J3
H1 J2 K1 K2J1
E4 F4 G3 G4F3E3
E2 F2 G1 G2F1E1
B4 C2 D1 D2C1B3
B2B1
A2
A1
KEY PLAN
P H
A S
E
P H
A S
E
D3
Z
R3
1/4" = 1'-0"
FURNITURE PLAN LEVEL B - AREA C2 - PHASE 1
0 2'-0" 4'-0" 8'-0"
C
B
ADMINISTRATIVE
CUBICLE
BG37B
OFA03
MALE PUBLIC
TOILET
BG41
TLTM2
N-S
CORRIDOR
LEVEL
BASEMENT PH
BD01
Z1100
N-S
CORRIDOR
LEVEL
BASEMENT PH
BD02
Z1100
F2010
F0275
F0205M-EF0205M-E
F2000
F3200
N-S
CORRIDOR
LEVEL
BASEMENT PH
BG01
Z1100
MATCHLINE IF-10B-G1MATCHLINE IF-10B-F2
MATCHLINE IF-10B-C2
MATCHLINE IF-10B-G2MATCHLINE IF-10B-G1
MATCHLINE IF-10B-D2
MATCHLINE IF-10B-C2 MATCHLINE IF-10B-D2
F0405
E0078M
MATCHLINE IF-10B-D3 MATCHLINE IF-10B-D3
F2025 F2000
F2025
COMMUNICATIONS
ROOM
BF45
COMC1
ELECTRICAL
ROOM BC
BG11
Z9301
PRIVATE
OFFICE
BG34
OFA02
CORRIDOR BC
BC01
Z9101
FURNITURE GENERAL NOTES
1. FURNITURE OVER 48" HIGH IS REQUIRED TO BE SEISMICALLY ANCHORED. THIS
WILL INCLUDE, BUT IS NOT LIMITED TO: FILE CABINETS, SHELVING UNITS,
BOOKCASES, AND MODULAR WORK STATION PANELS.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL PRODUCT
SPECIFIC ANCHORAGE DETAILS WITH THE FURNITURE MANUFACTURER.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE LOCATION
OF ALL REQUIRED WALL BACKING AND FLOOR ANCHORS WITH THE
FURNITURE MANUFACTURER.
4. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE STAMPED AND
SIGNED BY A LICENSED STRUCTURAL ENGINEER AUTHORIZED TO WORK BY
THE AGENCY HAVING JURISDICTION.
5. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE REVIEWED AND
APPROVED BY THE AGENCY HAVING JURISDICTION.
6. REFER TO BUILDING ELECTRICAL POWER AND DATA PLANS TO COORDINATE
SYSTEMS AND OTHER FURNITURE WHIP CONNECTIONS. FINAL LOCATIONS OF
FLOOR MOUNTED RECEPTACLES SHALL BE COORDINATED WITH FINAL
FURNITURE SELECTIONS.
7. THE SYSTEMS FURNITURE VENDOR IS RESPONSIBLE FOR PROVIDING POWER
WHIPS AND CONNECTING THEM BY A LICENSED ELECTRICIAN.
8. FURNITURE SYSTEMS VENDOR'S INSTALLATIONS SHALL NOT BE CONSIDERED
COMPLETE UNTIL ALL LAMPS AND ELECTRICAL OUTLETS OPERATE.
9. MANUFACTURER/FURNITURE VENDOR SHALL FIELD VERIFY DIMENSIONS
PRIOR TO PLACING FURNITURE ORDERS AND ARE RESPONSIBLE FOR
COORDINATING CHANGES DUE TO CONFLICTS WITH FIELD CONDITIONS.
VENDOR SHALL COORDINATE HANDED WORKSTATION AND PRIVATE OFFICE
FURNITURE LAYOUTS.
10. REFER TO FURNITURE ILLUSTRATION SHEETS FOR MORE INFORMATION.
FURNITURE CLARIFICATION NOTES
1. THE IF SERIES FURNITURE PLANS ARE FOR USE WITH THE COMPREHENSIVE
INTERIOR DESIGN (CID) PACKAGE FOR FURNITURE PLACEMENT AND
PROCUREMENT.
2. THE IF PLANS SHOW ALL ITEMS INCLUDED IN THE CID PACKAGE AS DASHED AND
TAGGED WITH RESPECTIVE JOINT SCHEDULE NUMBER (JSN) CODES.
3. EQUIPMENT ITEMS NOT INCLUDED IN THE CID PACKAGE ARE SHOWN DASHED AND
WITHOUT JSN CODES. THESE ITEMS ARE SHOWN ON THE IF PLANS FOR
COORDINATION AND SPATIAL RELATIONSHIP ONLY.
4. FOR PLANS NOTING JSN CODES FOR ALL LOGCAT EQUIPMENT ITEMS, REFER TO
THE Q-SERIES EQUIPMENT PLANS.
5. FURNITURE DEALER IS RESPONSIBLE FOR FIELD MEASURING PRIOR TO PLACING
ANY ORDER.
6. DESKS AND WALL MONITORS IN SOLID GREY OUTLINE ARE SHOWN FOR
COORDINATION PURPOSES ONLY AND ARE NOT IN CID PACKAGE. FOR ADDITIONAL
INFORMATION REFER TO TV STUDIO SECTION IN DRAWINGS AND SPECIFICATIONS
APPENDICES.
C
D
B
A
ARCHITECTURE | ENGINEERING
& CONSULTING
3001 WASHINGTON BLVD.
SUITE 200
ARLINGTON, VIRGINIA 22201
703-518-8500
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
NAVFAC DRAWING NO.
ePROJECT NO.:
SCALE:
SHEET OF
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
C
D
B
A
4321 5
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW REV
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
FIRE PROTECTION
As indicated
C rv t\
\A R
-1
-A
-F P
-C -P
-B
J O
S W
A L
D .r v t
/8
/2
:0
:1
P
M
IF-10B-D1
B A
S E
M E
N T
F U
R N
IT
U
R E
P L A
N
A R
E A
D
P H
A S
E
13090150
1171746
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N
A V
F A
C W
A S
H
IN
G T
O N
A T
L A
N T
IC
W
R N
M M
C
B e th e s d a
M
D
N S
A /B e th e s d a M
D B
E T
H E
S D
A M
D
P M
E D
IC
A
L C
E N
T E
R A
D D
IT
IO
N A
L T
E R
A T
IO
N
ROBSON/NOURI
NORTH
P1 Q1 R1 R2
Q2 R4
L2 M4 N3 N4M3
L1 M2 N1 N2M1
H2 J4 K3 K4J3
H1 J2 K1 K2J1
E4 F4 G3 G4F3E3
E2 F2 G1 G2F1E1
B4 C2 D1 D2C1B3
B2B1
A2
A1
KEY PLAN
P H
A S
E
P H
A S
E
D3
Z
R3
1/4" = 1'-0"
FURNITURE PLAN LEVEL B - AREA D1 - PHASE 1
0 2'-0" 4'-0" 8'-0"
C
B
GENERAL
STORAGE
BD11
SRS01
MATCHLINE IF-10B-G2MATCHLINE IF-10B-G1
MATCHLINE IF-10B-D1
MATCHLINE IF-10B-D1
F0405
MATCHLINE IF-10B-D3
F2000
F2025
E0117
F0275
N-S CORR
LEVEL B PH 1
N-S CORR
LEVEL B PH 1
BD02
Z1100
FURNITURE GENERAL NOTES
1. FURNITURE OVER 48" HIGH IS REQUIRED TO BE SEISMICALLY ANCHORED. THIS
WILL INCLUDE, BUT IS NOT LIMITED TO: FILE CABINETS, SHELVING UNITS,
BOOKCASES, AND MODULAR WORK STATION PANELS.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL PRODUCT
SPECIFIC ANCHORAGE DETAILS WITH THE FURNITURE MANUFACTURER.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE LOCATION
OF ALL REQUIRED WALL BACKING AND FLOOR ANCHORS WITH THE
FURNITURE MANUFACTURER.
4. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE STAMPED AND
SIGNED BY A LICENSED STRUCTURAL ENGINEER AUTHORIZED TO WORK BY
THE AGENCY HAVING JURISDICTION.
5. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE REVIEWED AND
APPROVED BY THE AGENCY HAVING JURISDICTION.
6. REFER TO BUILDING ELECTRICAL POWER AND DATA PLANS TO COORDINATE
SYSTEMS AND OTHER FURNITURE WHIP CONNECTIONS. FINAL LOCATIONS OF
FLOOR MOUNTED RECEPTACLES SHALL BE COORDINATED WITH FINAL
FURNITURE SELECTIONS.
7. THE SYSTEMS FURNITURE VENDOR IS RESPONSIBLE FOR PROVIDING POWER
WHIPS AND CONNECTING THEM BY A LICENSED ELECTRICIAN.
8. FURNITURE SYSTEMS VENDOR'S INSTALLATIONS SHALL NOT BE CONSIDERED
COMPLETE UNTIL ALL LAMPS AND ELECTRICAL OUTLETS OPERATE.
9. MANUFACTURER/FURNITURE VENDOR SHALL FIELD VERIFY DIMENSIONS
PRIOR TO PLACING FURNITURE ORDERS AND ARE RESPONSIBLE FOR
COORDINATING CHANGES DUE TO CONFLICTS WITH FIELD CONDITIONS.
VENDOR SHALL COORDINATE HANDED WORKSTATION AND PRIVATE OFFICE
FURNITURE LAYOUTS.
10. REFER TO FURNITURE ILLUSTRATION SHEETS FOR MORE INFORMATION.
FURNITURE CLARIFICATION NOTES
1. THE IF SERIES FURNITURE PLANS ARE FOR USE WITH THE COMPREHENSIVE
INTERIOR DESIGN (CID) PACKAGE FOR FURNITURE PLACEMENT AND
PROCUREMENT.
2. THE IF PLANS SHOW ALL ITEMS INCLUDED IN THE CID PACKAGE AS DASHED AND
TAGGED WITH RESPECTIVE JOINT SCHEDULE NUMBER (JSN) CODES.
3. EQUIPMENT ITEMS NOT INCLUDED IN THE CID PACKAGE ARE SHOWN DASHED AND
WITHOUT JSN CODES. THESE ITEMS ARE SHOWN ON THE IF PLANS FOR
COORDINATION AND SPATIAL RELATIONSHIP ONLY.
4. FOR PLANS NOTING JSN CODES FOR ALL LOGCAT EQUIPMENT ITEMS, REFER TO
THE Q-SERIES EQUIPMENT PLANS.
5. FURNITURE DEALER IS RESPONSIBLE FOR FIELD MEASURING PRIOR TO PLACING
ANY ORDER.
6. DESKS AND WALL MONITORS IN SOLID GREY OUTLINE ARE SHOWN FOR
COORDINATION PURPOSES ONLY AND ARE NOT IN CID PACKAGE. FOR ADDITIONAL
INFORMATION REFER TO TV STUDIO SECTION IN DRAWINGS AND SPECIFICATIONS
APPENDICES.
C
D
B
A
ARCHITECTURE | ENGINEERING
& CONSULTING
3001 WASHINGTON BLVD.
SUITE 200
ARLINGTON, VIRGINIA 22201
703-518-8500
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
NAVFAC DRAWING NO.
ePROJECT NO.:
SCALE:
SHEET OF
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
C
D
B
A
4321 5
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW REV
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
FIRE PROTECTION
As indicated
C rv t\
\A R
-1
-A
-F P
-C -P
-B
J O
S W
A L
D .r v t
/8
/2
:0
:0
P
M
IF-10B-D2
B A
S E
M E
N T
F U
R N
IT
U
R E
P L A
N
A R
E A
D
P H
A S
E
13090151
1171746
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N
A V
F A
C W
A S
H
IN
G T
O N
A T
L A
N T
IC
W
R N
M M
C
B e th e s d a
M
D
N S
A /B e th e s d a M
D B
E T
H E
S D
A M
D
P M
E D
IC
A
L C
E N
T E
R A
D D
IT
IO
N A
L T
E R
A T
IO
N
ROBSON/NOURI
NORTH
P1 Q1 R1 R2
Q2 R4
L2 M4 N3 N4M3
L1 M2 N1 N2M1
H2 J4 K3 K4J3
H1 J2 K1 K2J1
E4 F4 G3 G4F3E3
E2 F2 G1 G2F1E1
B4 C2 D1 D2C1B3
B2B1
A2
A1
KEY PLAN
P H
A S
E
P H
A S
E
D3
Z
R3
1/4" = 1'-0"
FURNITURE PLAN LEVEL B - AREA D2 - PHASE 1
0 2'-0" 4'-0" 8'-0"
F
E
CC
DD
EE
FF
WAITWAIT
BE11
WRC01
CORRIDOR BC
BB07
Z9101
CORRIDOR BC
BB04
Z9101
RECEPTION
BE12
RECP1
F0250-B
F0250-B
F0250-B
F0740M1
F0740M1
F0250-B
F0740M1
F3200
F2300M
A6046
A6046
E0042
F2300M
F2420
F2420
F2420
MATCHLINE IF-10B-E4
MATCHLINE IF-10B-E2
MATCHLINE IF-10B-E2
MATCHLINE IF-10B-B4MATCHLINE IF-10B-B3
F0250-B
F0275
E0084M1
F0420
F0275
F0375M-I
F0250-B
F0250-B
F0250-B
MATCHLINE IF-10B-B3
F0275
F2000 F2025
E0123
CORRIDOR BC
BB07
Z9101
F2000
FURNITURE GENERAL NOTES
1. FURNITURE OVER 48" HIGH IS REQUIRED TO BE SEISMICALLY ANCHORED. THIS
WILL INCLUDE, BUT IS NOT LIMITED TO: FILE CABINETS, SHELVING UNITS,
BOOKCASES, AND MODULAR WORK STATION PANELS.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL PRODUCT
SPECIFIC ANCHORAGE DETAILS WITH THE FURNITURE MANUFACTURER.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE LOCATION
OF ALL REQUIRED WALL BACKING AND FLOOR ANCHORS WITH THE
FURNITURE MANUFACTURER.
4. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE STAMPED AND
SIGNED BY A LICENSED STRUCTURAL ENGINEER AUTHORIZED TO WORK BY
THE AGENCY HAVING JURISDICTION.
5. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE REVIEWED AND
APPROVED BY THE AGENCY HAVING JURISDICTION.
6. REFER TO BUILDING ELECTRICAL POWER AND DATA PLANS TO COORDINATE
SYSTEMS AND OTHER FURNITURE WHIP CONNECTIONS. FINAL LOCATIONS OF
FLOOR MOUNTED RECEPTACLES SHALL BE COORDINATED WITH FINAL
FURNITURE SELECTIONS.
7. THE SYSTEMS FURNITURE VENDOR IS RESPONSIBLE FOR PROVIDING POWER
WHIPS AND CONNECTING THEM BY A LICENSED ELECTRICIAN.
8. FURNITURE SYSTEMS VENDOR'S INSTALLATIONS SHALL NOT BE CONSIDERED
COMPLETE UNTIL ALL LAMPS AND ELECTRICAL OUTLETS OPERATE.
9. MANUFACTURER/FURNITURE VENDOR SHALL FIELD VERIFY DIMENSIONS
PRIOR TO PLACING FURNITURE ORDERS AND ARE RESPONSIBLE FOR
COORDINATING CHANGES DUE TO CONFLICTS WITH FIELD CONDITIONS.
VENDOR SHALL COORDINATE HANDED WORKSTATION AND PRIVATE OFFICE
FURNITURE LAYOUTS.
10. REFER TO FURNITURE ILLUSTRATION SHEETS FOR MORE INFORMATION.
FURNITURE CLARIFICATION NOTES
1. THE IF SERIES FURNITURE PLANS ARE FOR USE WITH THE COMPREHENSIVE
INTERIOR DESIGN (CID) PACKAGE FOR FURNITURE PLACEMENT AND
PROCUREMENT.
2. THE IF PLANS SHOW ALL ITEMS INCLUDED IN THE CID PACKAGE AS DASHED AND
TAGGED WITH RESPECTIVE JOINT SCHEDULE NUMBER (JSN) CODES.
3. EQUIPMENT ITEMS NOT INCLUDED IN THE CID PACKAGE ARE SHOWN DASHED AND
WITHOUT JSN CODES. THESE ITEMS ARE SHOWN ON THE IF PLANS FOR
COORDINATION AND SPATIAL RELATIONSHIP ONLY.
4. FOR PLANS NOTING JSN CODES FOR ALL LOGCAT EQUIPMENT ITEMS, REFER TO
THE Q-SERIES EQUIPMENT PLANS.
5. FURNITURE DEALER IS RESPONSIBLE FOR FIELD MEASURING PRIOR TO PLACING
ANY ORDER.
6. DESKS AND WALL MONITORS IN SOLID GREY OUTLINE ARE SHOWN FOR
COORDINATION PURPOSES ONLY AND ARE NOT IN CID PACKAGE. FOR ADDITIONAL
INFORMATION REFER TO TV STUDIO SECTION IN DRAWINGS AND SPECIFICATIONS
APPENDICES.
C
D
B
A
ARCHITECTURE | ENGINEERING
& CONSULTING
3001 WASHINGTON BLVD.
SUITE 200
ARLINGTON, VIRGINIA 22201
703-518-8500
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
NAVFAC DRAWING NO.
ePROJECT NO.:
SCALE:
SHEET OF
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
C
D
B
A
4321 5
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW REV
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
FIRE PROTECTION
As indicated
C rv t\
\A R
-1
-A
-F P
-C -P
-B
J O
S W
A L
D .r v t
/8
/2
:0
:3
P
M
IF-10B-E1
B A
S E
M E
N T
F U
R N
IT
U
R E
P L A
N
A R
E A
E
P H
A S
E
13090152
1171746
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N
A V
F A
C W
A S
H
IN
G T
O N
A T
L A
N T
IC
W
R N
M M
C
B e th e s d a
M
D
N S
A /B e th e s d a M
D B
E T
H E
S D
A M
D
P M
E D
IC
A
L C
E N
T E
R A
D D
IT
IO
N A
L T
E R
A T
IO
N
ROBSON/NOURI
NORTH
P1 Q1 R1 R2
Q2 R4
L2 M4 N3 N4M3
L1 M2 N1 N2M1
H2 J4 K3 K4J3
H1 J2 K1 K2J1
E4 F4 G3 G4F3E3
E2 F2 G1 G2F1E1
B4 C2 D1 D2C1B3
B2B1
A2
A1
KEY PLAN
P H
A S
E
P H
A S
E
D3
Z
R3
1/4" = 1'-0"
FURNITURE PLAN LEVEL B - AREA E1 - PHASE 1
0 2'-0" 4'-0" 8'-0"
E
21 22
DD
EE
FF
PATIENT
STUDIO
BE18
MIST1
PASSPORT
BE15
OFA02
MASTER
CONTROL
BF18
MIST1
VTC
MANAGER
BE23
OFA02
ELECTRICAL
ROOM BC
BE14
Z9301
EDIT
BF12
MIST1
EDIT
BF11
MIST1
CORRIDOR BC
BB04
Z9101
CORRIDOR BC
BB05
Z9101
RECEPTION
BE12
RECP1
FILE ROOM,
GENERAL USE
BE13
FILE1
E0099M E0099M
F0275 F0275F0275
F0275
F0275
E0084
F0275
F0275
E0099M
E0099M
E0099M
E0099M
E0078M
F0275
F0205M-E
A6046
F3200
F0205M-E
E0820
E0078
F0275
F0205M-E
E0820
A6046
F3200
F2000
F0205M-E
E0084
F2000 F2025
F2000 F2025
F2000 F2025
F2000 F2025
F2000 F2025
F2000 F2025
F2000 F2025
F2000 F2025
F0205M-E
F0205M-E
F0205M-E
F0205M-EF0205M-E
F0205M-E
F0415
A6046F0415
F0415
F2025
F2000 F2025
F3200
F0250-B
F2000F2025
F3200
F2300M
A6046
E0042
F0415
CORRIDOR BC
BF01
Z9101
CORRIDOR BC
BE01
Z9101
MATCHLINE IF-10B-E4
MATCHLINE IF-10B-E1
MATCHLINE IF-10B-F3MATCHLINE IF-10B-E4
MATCHLINE IF-10B-F1
MATCHLINE IF-10B-E1
MATCHLINE IF-10B-B4MATCHLINE IF-10B-B3
MATCHLINE IF-10B-F1
MATCHLINE IF-10B-C1MATCHLINE IF-10B-B4
F0340
F0275
F0420
F0250-B
F2010
PASSENGER
ELEVATOR P7
4000 LB
BBESW
Z9103
PATIENT
TRANSPORT
ELEVATOR H1
6000 LB
BBESE
Z9103
PATIENT
TRANSPORT
ELEVATOR H2
6000 LB
BBENE
Z9103
PASSENGER
ELEVATOR P8
4000 LB
BBENW
Z9103
F0275
F2010
COMMUNICATIONS
ROOM
BE17
COMC1
FEMALE
PUBLIC
TOILET
BE10
TLTF2
F2000
F2025
F0275
F3200
E0123
F2000 F2025
F0275E0123
F0275
A6046
CORRIDOR BC
BE02
Z9101
ADMINISTRATIVE
CUBICLES
BE24
OFA02
F3200
F3200
F3200
F2025
F2000
F2025
F2000
F2025
F2000
F2025
F2000
F2000
F2025
FURNITURE GENERAL NOTES
1. FURNITURE OVER 48" HIGH IS REQUIRED TO BE SEISMICALLY ANCHORED. THIS
WILL INCLUDE, BUT IS NOT LIMITED TO: FILE CABINETS, SHELVING UNITS,
BOOKCASES, AND MODULAR WORK STATION PANELS.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL PRODUCT
SPECIFIC ANCHORAGE DETAILS WITH THE FURNITURE MANUFACTURER.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE LOCATION
OF ALL REQUIRED WALL BACKING AND FLOOR ANCHORS WITH THE
FURNITURE MANUFACTURER.
4. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE STAMPED AND
SIGNED BY A LICENSED STRUCTURAL ENGINEER AUTHORIZED TO WORK BY
THE AGENCY HAVING JURISDICTION.
5. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE REVIEWED AND
APPROVED BY THE AGENCY HAVING JURISDICTION.
6. REFER TO BUILDING ELECTRICAL POWER AND DATA PLANS TO COORDINATE
SYSTEMS AND OTHER FURNITURE WHIP CONNECTIONS. FINAL LOCATIONS OF
FLOOR MOUNTED RECEPTACLES SHALL BE COORDINATED WITH FINAL
FURNITURE SELECTIONS.
7. THE SYSTEMS FURNITURE VENDOR IS RESPONSIBLE FOR PROVIDING POWER
WHIPS AND CONNECTING THEM BY A LICENSED ELECTRICIAN.
8. FURNITURE SYSTEMS VENDOR'S INSTALLATIONS SHALL NOT BE CONSIDERED
COMPLETE UNTIL ALL LAMPS AND ELECTRICAL OUTLETS OPERATE.
9. MANUFACTURER/FURNITURE VENDOR SHALL FIELD VERIFY DIMENSIONS
PRIOR TO PLACING FURNITURE ORDERS AND ARE RESPONSIBLE FOR
COORDINATING CHANGES DUE TO CONFLICTS WITH FIELD CONDITIONS.
VENDOR SHALL COORDINATE HANDED WORKSTATION AND PRIVATE OFFICE
FURNITURE LAYOUTS.
10. REFER TO FURNITURE ILLUSTRATION SHEETS FOR MORE INFORMATION.
FURNITURE CLARIFICATION NOTES
1. THE IF SERIES FURNITURE PLANS ARE FOR USE WITH THE COMPREHENSIVE
INTERIOR DESIGN (CID) PACKAGE FOR FURNITURE PLACEMENT AND
PROCUREMENT.
2. THE IF PLANS SHOW ALL ITEMS INCLUDED IN THE CID PACKAGE AS DASHED AND
TAGGED WITH RESPECTIVE JOINT SCHEDULE NUMBER (JSN) CODES.
3. EQUIPMENT ITEMS NOT INCLUDED IN THE CID PACKAGE ARE SHOWN DASHED AND
WITHOUT JSN CODES. THESE ITEMS ARE SHOWN ON THE IF PLANS FOR
COORDINATION AND SPATIAL RELATIONSHIP ONLY.
4. FOR PLANS NOTING JSN CODES FOR ALL LOGCAT EQUIPMENT ITEMS, REFER TO
THE Q-SERIES EQUIPMENT PLANS.
5. FURNITURE DEALER IS RESPONSIBLE FOR FIELD MEASURING PRIOR TO PLACING
ANY ORDER.
6. DESKS AND WALL MONITORS IN SOLID GREY OUTLINE ARE SHOWN FOR
COORDINATION PURPOSES ONLY AND ARE NOT IN CID PACKAGE. FOR ADDITIONAL
INFORMATION REFER TO TV STUDIO SECTION IN DRAWINGS AND SPECIFICATIONS
APPENDICES.
C
D
B
A
ARCHITECTURE | ENGINEERING
& CONSULTING
3001 WASHINGTON BLVD.
SUITE 200
ARLINGTON, VIRGINIA 22201
703-518-8500
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
NAVFAC DRAWING NO.
ePROJECT NO.:
SCALE:
SHEET OF
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
C
D
B
A
4321 5
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW REV
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
FIRE PROTECTION
As indicated
C rv t\
\A R
-1
-A
-F P
-C -P
-B
J O
S W
A L
D .r v t
/8
/2
:0
:0
P
M
IF-10B-E2
B A
S E
M E
N T
F U
R N
IT
U
R E
P L A
N
A R
E A
E
P H
A S
E
13090153
1171746
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N
A V
F A
C W
A S
H
IN
G T
O N
A T
L A
N T
IC
W
R N
M M
C
B e th e s d a
M
D
N S
A /B e th e s d a M
D B
E T
H E
S D
A M
D
P M
E D
IC
A
L C
E N
T E
R A
D D
IT
IO
N A
L T
E R
A T
IO
N
ROBSON/NOURI
NORTH
P1 Q1 R1 R2
Q2 R4
L2 M4 N3 N4M3
L1 M2 N1 N2M1
H2 J4 K3 K4J3
H1 J2 K1 K2J1
E4 F4 G3 G4F3E3
E2 F2 G1 G2F1E1
B4 C2 D1 D2C1B3
B2B1
A2
A1
KEY PLAN
P H
A S
E
P H
A S
E
D3
Z
R3
1/4" = 1'-0"
FURNITURE PLAN LEVEL B - AREA E2 - PHASE 1
0 2'-0" 4'-0" 8'-0"
H
G
F
21 22
FF
GG
HH
PORTRAIT
STUDIO
BE19
MIST1
DEPARTMENT
HEAD
BH11
OFA02
PUBLIC
RELATIONS
BE26
OFA02
DIGITAL
ROOM
BE21
MIPP1
CUBICLE
CORRIDOR
BE22
Z9101
ADMINISTRATIVE
CUBICLES
BE24
OFA02
PASSPORT
BE25
OFA02
PASSPORT
BE27
OFA02
RECEPTION
BE28
RECP1
F0275
E0084
F0275
F0275
F2005
F0120
F0690
F3200
A6046 F3200
E0078M
F0205M-E F0205M-E
E0099M
E0099M
E0099M
E0099M
E0099M
F0275
F0205M-E
E0820
A6046
F3200
F2000
F0205M-E
F0275
F0205M-E
E0820
F2000
E0078M
F0205M-E
A6046
F3200
E0078M
E0820
F0275
F2000
F0205M-E
A6046
F3200
F0275
E0084
F0275
F0275
F2025
F2025
F2025
F2000 F2025
F2000 F2025
F2000
F2025
F2000 F2025
F2000 F2025
F2000 F2025
F2000 F2025
F2025
F0205M-E
F0205M-E
F0205M-E
F0205M-E
F0205M-E
F0415
A6046
F3200
A6046F0415
CORRIDOR BC
BF01
Z9101
CORRIDOR BC
BE02
Z9101
MATCHLINE IF-10B-H1 MATCHLINE IF-10B-J1MATCHLINE IF-10B-H1
MATCHLINE IF-10B-F3
MATCHLINE IF-10B-E2MATCHLINE IF-10B-E1
MATCHLINE IF-10B-F3
MATCHLINE IF-10B-F1MATCHLINE IF-10B-E2
F0420
F0205M-E
F0275
E0078M1
F0420
F3200
A6046
F0205M-E
F0275
F0275
E0084 E0084
F0205M-E
F0205M-E
F0340
E0078M1
F0420
F0420
F2000F2025
ADMINISTRATIVE
CUBICLE
BE31
OFA03
ADMINISTRATIVE
CUBICLE
BE32
OFA03
F2000 F2025
F2000 F2025
MATCHLINE IF-10B-E3
F2010
E0123
E0123
F2000 F2025
F2000
F2025
F0275
F0275
F3200
F2000
F2025
F0275
E0123
F2000 F2025
F0275
E0123
F3200
F2000
F2025
F0275
F3200
E0123
F2000 F2025
F0275E0123
F2000
F2000
F0275
CORRIDOR BC
BE03
Z9101
F3200
ADMIN OFF
SYST FURN
ADMIN OFF
SYST FURN
BJ11
OFA02
FURNITURE GENERAL NOTES
1. FURNITURE OVER 48" HIGH IS REQUIRED TO BE SEISMICALLY ANCHORED. THIS
WILL INCLUDE, BUT IS NOT LIMITED TO: FILE CABINETS, SHELVING UNITS,
BOOKCASES, AND MODULAR WORK STATION PANELS.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL PRODUCT
SPECIFIC ANCHORAGE DETAILS WITH THE FURNITURE MANUFACTURER.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE LOCATION
OF ALL REQUIRED WALL BACKING AND FLOOR ANCHORS WITH THE
FURNITURE MANUFACTURER.
4. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE STAMPED AND
SIGNED BY A LICENSED STRUCTURAL ENGINEER AUTHORIZED TO WORK BY
THE AGENCY HAVING JURISDICTION.
5. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE REVIEWED AND
APPROVED BY THE AGENCY HAVING JURISDICTION.
6. REFER TO BUILDING ELECTRICAL POWER AND DATA PLANS TO COORDINATE
SYSTEMS AND OTHER FURNITURE WHIP CONNECTIONS. FINAL LOCATIONS OF
FLOOR MOUNTED RECEPTACLES SHALL BE COORDINATED WITH FINAL
FURNITURE SELECTIONS.
7. THE SYSTEMS FURNITURE VENDOR IS RESPONSIBLE FOR PROVIDING POWER
WHIPS AND CONNECTING THEM BY A LICENSED ELECTRICIAN.
8. FURNITURE SYSTEMS VENDOR'S INSTALLATIONS SHALL NOT BE CONSIDERED
COMPLETE UNTIL ALL LAMPS AND ELECTRICAL OUTLETS OPERATE.
9. MANUFACTURER/FURNITURE VENDOR SHALL FIELD VERIFY DIMENSIONS
PRIOR TO PLACING FURNITURE ORDERS AND ARE RESPONSIBLE FOR
COORDINATING CHANGES DUE TO CONFLICTS WITH FIELD CONDITIONS.
VENDOR SHALL COORDINATE HANDED WORKSTATION AND PRIVATE OFFICE
FURNITURE LAYOUTS.
10. REFER TO FURNITURE ILLUSTRATION SHEETS FOR MORE INFORMATION.
FURNITURE CLARIFICATION NOTES
1. THE IF SERIES FURNITURE PLANS ARE FOR USE WITH THE COMPREHENSIVE
INTERIOR DESIGN (CID) PACKAGE FOR FURNITURE PLACEMENT AND
PROCUREMENT.
2. THE IF PLANS SHOW ALL ITEMS INCLUDED IN THE CID PACKAGE AS DASHED AND
TAGGED WITH RESPECTIVE JOINT SCHEDULE NUMBER (JSN) CODES.
3. EQUIPMENT ITEMS NOT INCLUDED IN THE CID PACKAGE ARE SHOWN DASHED AND
WITHOUT JSN CODES. THESE ITEMS ARE SHOWN ON THE IF PLANS FOR
COORDINATION AND SPATIAL RELATIONSHIP ONLY.
4. FOR PLANS NOTING JSN CODES FOR ALL LOGCAT EQUIPMENT ITEMS, REFER TO
THE Q-SERIES EQUIPMENT PLANS.
5. FURNITURE DEALER IS RESPONSIBLE FOR FIELD MEASURING PRIOR TO PLACING
ANY ORDER.
6. DESKS AND WALL MONITORS IN SOLID GREY OUTLINE ARE SHOWN FOR
COORDINATION PURPOSES ONLY AND ARE NOT IN CID PACKAGE. FOR ADDITIONAL
INFORMATION REFER TO TV STUDIO SECTION IN DRAWINGS AND SPECIFICATIONS
APPENDICES.
C
D
B
A
ARCHITECTURE | ENGINEERING
& CONSULTING
3001 WASHINGTON BLVD.
SUITE 200
ARLINGTON, VIRGINIA 22201
703-518-8500
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
NAVFAC DRAWING NO.
ePROJECT NO.:
SCALE:
SHEET OF
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
C
D
B
A
4321 5
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW REV
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
FIRE PROTECTION
As indicated
C rv t\
\A R
-1
-A
-F P
-C -P
-B
J O
S W
A L
D .r v t
/8
/2
:0
:1
P
M
IF-10B-E4
B A
S E
M E
N T
F U
R N
IT
U
R E
P L A
N
A R
E A
E
P H
A S
E
13090154
1171746
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N
A V
F A
C W
A S
H
IN
G T
O N
A T
L A
N T
IC
W
R N
M M
C
B e th e s d a
M
D
N S
A /B e th e s d a M
D B
E T
H E
S D
A M
D
P M
E D
IC
A
L C
E N
T E
R A
D D
IT
IO
N A
L T
E R
A T
IO
N
ROBSON/NOURI
NORTH
P1 Q1 R1 R2
Q2 R4
L2 M4 N3 N4M3
L1 M2 N1 N2M1
H2 J4 K3 K4J3
H1 J2 K1 K2J1
E4 F4 G3 G4F3E3
E2 F2 G1 G2F1E1
B4 C2 D1 D2C1B3
B2B1
A2
A1
KEY PLAN
P H
A S
E
P H
A S
E
D3
Z
R3
1/4" = 1'-0"
FURNITURE PLAN LEVEL B - AREA E4 - PHASE 1
0 2'-0" 4'-0" 8'-0"
E
CENTRAL
LOCKER
ROOM (MALE)
SHOWER
BF47
SHWR1
CENTRAL
LOCKER
ROOM
(FEMALE)
SHOWER
BF51
SHWR1
CENTRAL
LOCKER
ROOM
(FEMALE)
TOILET
BF52
TLTU1
CENTRAL
LOCKER
ROOM (MALE)
TOILET
BF48
TLTU1
HEALTH
PHYSICIST
OFFICE
BF41A
OFA03
COPY/ PRINT
AREA
BF46
RPR01
CONFERENCE
ROOM,
MEDIUM
BF19
CRA02
NARRATION
BF17
AVPD1
SERVER
BE16
CMP02
EDIT
BF14
MIST1
EDIT
BF15
MIST1
EDIT
BF13
MIST1
ENGINEERING
BF16
MIST1
CUSTOMER
SERVICE
AREA
BF21
OFA03
N-S
CORRIDOR
LEVEL
BASEMENT PH
BF32
Z1100
EDIT
BF12
MIST1
EDIT
BF11
MIST1
CORRIDOR BC
BF41
Z9101
STUDIO
CONTROL
ROOM
BB17
MIST1
E0099M
F0275
F0275
E0099M
E0099M
F0115
F0220-A
F3050
F0220-A
F0220-A
F0220-A
F0220-A
F0220-A
F0210
F3200
E0099M E0099M
F0275F0275
F0205M-E F0205M-E
F0102
U5007
F2000
F2000 F2025
F2000 F2025
F2000 F2025
F0205M-E
F0205M-E
F3200
F0420
F2025
F2026
F3050 F3050
F0415
F2000
F2025
F0795M2 F0210
F0210
F0220-AF0295-B
F0220-A
F0220-A
F0220-A
F0220-A
F0755F0755
F0755 F0755
F2000F2025
A6046
F3200
CORRIDOR BC
BF02
Z9101
CORRIDOR BC
BF01
Z9101
CORRIDOR BC
BC01
Z9101
MATCHLINE IF-10B-F3MATCHLINE IF-10B-E4
MATCHLINE IF-10B-E2
MATCHLINE IF-10B-F4MATCHLINE IF-10B-F3
MATCHLINE IF-10B-F2
MATCHLINE IF-10B-E2
MATCHLINE IF-10B-C1MATCHLINE IF-10B-B4
MATCHLINE IF-10B-F2
MATCHLINE IF-10B-C2MATCHLINE IF-10B-C1
F0465 F0465 F0465 E0117
F0275
F2025
F2000
E0117
E0117
F0275 F0275 F0275F2026
F0275E0078M
E0820
F2025F2000
F0205M-E
A6046
F3200
F0295-B
F0295-B
F0295-B
F0295-BF0295-B
F0220-A
F2100
U5008U5008U5008
EDIT
BF13A
MIST1
F0275
CUBICLE
CORRIDOR
BF22
Z9101
MGAD STUDIOMGAD STUDIO
BF23
MIST1
F3200 F3200
F3200 F3200
F3200 F3200
F3200
F2025
F2000
F2025
F2000
F2025
F2000
F2025F2000
F2025 F2000
F2025 F2000
F2025 F2000
F2025 F2000
F2000 F2025 F2025
F2000
CORRIDOR BC
BB05
Z9101
F3230
FURNITURE GENERAL NOTES
1. FURNITURE OVER 48" HIGH IS REQUIRED TO BE SEISMICALLY ANCHORED. THIS
WILL INCLUDE, BUT IS NOT LIMITED TO: FILE CABINETS, SHELVING UNITS,
BOOKCASES, AND MODULAR WORK STATION PANELS.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL PRODUCT
SPECIFIC ANCHORAGE DETAILS WITH THE FURNITURE MANUFACTURER.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE LOCATION
OF ALL REQUIRED WALL BACKING AND FLOOR ANCHORS WITH THE
FURNITURE MANUFACTURER.
4. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE STAMPED AND
SIGNED BY A LICENSED STRUCTURAL ENGINEER AUTHORIZED TO WORK BY
THE AGENCY HAVING JURISDICTION.
5. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE REVIEWED AND
APPROVED BY THE AGENCY HAVING JURISDICTION.
6. REFER TO BUILDING ELECTRICAL POWER AND DATA PLANS TO COORDINATE
SYSTEMS AND OTHER FURNITURE WHIP CONNECTIONS. FINAL LOCATIONS OF
FLOOR MOUNTED RECEPTACLES SHALL BE COORDINATED WITH FINAL
FURNITURE SELECTIONS.
7. THE SYSTEMS FURNITURE VENDOR IS RESPONSIBLE FOR PROVIDING POWER
WHIPS AND CONNECTING THEM BY A LICENSED ELECTRICIAN.
8. FURNITURE SYSTEMS VENDOR'S INSTALLATIONS SHALL NOT BE CONSIDERED
COMPLETE UNTIL ALL LAMPS AND ELECTRICAL OUTLETS OPERATE.
9. MANUFACTURER/FURNITURE VENDOR SHALL FIELD VERIFY DIMENSIONS
PRIOR TO PLACING FURNITURE ORDERS AND ARE RESPONSIBLE FOR
COORDINATING CHANGES DUE TO CONFLICTS WITH FIELD CONDITIONS.
VENDOR SHALL COORDINATE HANDED WORKSTATION AND PRIVATE OFFICE
FURNITURE LAYOUTS.
10. REFER TO FURNITURE ILLUSTRATION SHEETS FOR MORE INFORMATION.
FURNITURE CLARIFICATION NOTES
1. THE IF SERIES FURNITURE PLANS ARE FOR USE WITH THE COMPREHENSIVE
INTERIOR DESIGN (CID) PACKAGE FOR FURNITURE PLACEMENT AND
PROCUREMENT.
2. THE IF PLANS SHOW ALL ITEMS INCLUDED IN THE CID PACKAGE AS DASHED AND
TAGGED WITH RESPECTIVE JOINT SCHEDULE NUMBER (JSN) CODES.
3. EQUIPMENT ITEMS NOT INCLUDED IN THE CID PACKAGE ARE SHOWN DASHED AND
WITHOUT JSN CODES. THESE ITEMS ARE SHOWN ON THE IF PLANS FOR
COORDINATION AND SPATIAL RELATIONSHIP ONLY.
4. FOR PLANS NOTING JSN CODES FOR ALL LOGCAT EQUIPMENT ITEMS, REFER TO
THE Q-SERIES EQUIPMENT PLANS.
5. FURNITURE DEALER IS RESPONSIBLE FOR FIELD MEASURING PRIOR TO PLACING
ANY ORDER.
6. DESKS AND WALL MONITORS IN SOLID GREY OUTLINE ARE SHOWN FOR
COORDINATION PURPOSES ONLY AND ARE NOT IN CID PACKAGE. FOR ADDITIONAL
INFORMATION REFER TO TV STUDIO SECTION IN DRAWINGS AND SPECIFICATIONS
APPENDICES.
C
D
B
A
ARCHITECTURE | ENGINEERING
& CONSULTING
3001 WASHINGTON BLVD.
SUITE 200
ARLINGTON, VIRGINIA 22201
703-518-8500
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
NAVFAC DRAWING NO.
ePROJECT NO.:
SCALE:
SHEET OF
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
C
D
B
A
4321 5
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW REV
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
FIRE PROTECTION
As indicated
C rv t\
\A R
-1
-A
-F P
-C -P
-B
J O
S W
A L
D .r v t
/8
/2
:0
:4
P
M
IF-10B-F1
B A
S E
M E
N T
F U
R N
IT
U
R E
P L A
N
A R
E A
F
P H
A S
E
13090155
1171746
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N
A V
F A
C W
A S
H
IN
G T
O N
A T
L A
N T
IC
W
R N
M M
C
B e th e s d a
M
D
N S
A /B e th e s d a M
D B
E T
H E
S D
A M
D
P M
E D
IC
A
L C
E N
T E
R A
D D
IT
IO
N A
L T
E R
A T
IO
N
ROBSON/NOURI
NORTH
P1 Q1 R1 R2
Q2 R4
L2 M4 N3 N4M3
L1 M2 N1 N2M1
H2 J4 K3 K4J3
H1 J2 K1 K2J1
E4 F4 G3 G4F3E3
E2 F2 G1 G2F1E1
B4 C2 D1 D2C1B3
B2B1
A2
A1
KEY PLAN
P H
A S
E
P H
A S
E
D3
Z
R3
1/4" = 1'-0"
FURNITURE PLAN LEVEL B - AREA F1 - PHASE 1
0 2'-0" 4'-0" 8'-0"
E
SAFETY AND
HEALTH
BF41C
OFA03
SCIENCE
ADVISOR
BF42
OFM01
VENDING
AREA
BF55
BX001
CENTRAL
LOCKER
ROOM
(FEMALE)
BF53
LR002
CENTRAL
LOCKER
ROOM (MALE)
BF49
LR002
CENTRAL
LOCKER
ROOM (MALE)
SHOWER
BF47
SHWR1
CENTRAL
LOCKER
ROOM
(FEMALE)
SHOWER
BF51
SHWR1
CENTRAL
LOCKER
ROOM
(FEMALE)
TOILET
BF52
TLTU1
CENTRAL
LOCKER
ROOM (MALE)
TOILET
BF48
TLTU1
PROCESSING
LAB
BF59
LBMN1
RESEARCH
AREA
BF43
LIBS1
RADIATION
SAFETY
OFFICER
(00OD-ED)
BF41B
OFA02
TLD SHIPPING
CLERK
BF61
OFA03
TLD SHIPPING
CLERK
BF58
OFA03
SUPERVISOR
FOR
OPERATIONS
BF62
OFA03
HEALTH
PHYSICIST
OFFICE
BF41A
OFA03
COPY/ PRINT
AREA
BF46
RPR01
CORRIDOR BC
BF41
Z9101
DOSIMETRY
LAB
BF44
LBMN1
JANITORS'
CLOSET
BF56
JANC1
STORAGE
ROOM, TLD
BG13
SRS01
COMMUNICATIONS
ROOM
BF45
COMC1
F0210 F0275
F0205M-E
A6046
F3200
F2000
E0078M2
F0205M-E
F0275 F0420
F2000
E0078M2
F0205M-E
F3200
A6046
E0099M E0099M E0099M
E0084
F0275
F0275
F0275F0275F0275
F0205M-E F0205M-E F0205M-E
F0102
F0465U5007
F0230
F2000
F3050
F3200
F3200F3200
A6046
E0114M
F0275
F0465
F0115
F0205M-E
E0820
F0205M-E
F0420
F3050
F0115
F0115
F2010
F2010
F0230M
F2000
F2000 F2025
F2000 F2025
F0420
F2025
F2026
F3050 F3050 F3050
F0415 F0415 F0415
F2000
F2025
F2000
F2025
F0795M2 F0210
F0210
F3200
F2025 F2025
F0420
F3200
F3200
F2025
F0230
F0230M
F0230M F0230
F2000 F2025
F2025
F2000
CORRIDOR BC
BC01
Z9101
CORRIDOR BC
BF04
Z9101
CORRIDOR BC
BF05
Z9101
MATCHLINE IF-10B-F4MATCHLINE IF-10B-F3
MATCHLINE IF-10B-F1
MATCHLINE IF-10B-G3MATCHLINE IF-10B-F4
MATCHLINE IF-10B-G1
MATCHLINE IF-10B-F1
MATCHLINE IF-10B-C2MATCHLINE IF-10B-C1
MATCHLINE IF-10B-G1
MATCHLINE IF-10B-D1MATCHLINE IF-10B-C2
E0084
F2000F2025
E0820
ELECTRICAL
ROOM BC
BG11
Z9301
COMMCOMM
BG12
COMC1
FURNITURE GENERAL NOTES
1. FURNITURE OVER 48" HIGH IS REQUIRED TO BE SEISMICALLY ANCHORED. THIS
WILL INCLUDE, BUT IS NOT LIMITED TO: FILE CABINETS, SHELVING UNITS,
BOOKCASES, AND MODULAR WORK STATION PANELS.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL PRODUCT
SPECIFIC ANCHORAGE DETAILS WITH THE FURNITURE MANUFACTURER.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE LOCATION
OF ALL REQUIRED WALL BACKING AND FLOOR ANCHORS WITH THE
FURNITURE MANUFACTURER.
4. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE STAMPED AND
SIGNED BY A LICENSED STRUCTURAL ENGINEER AUTHORIZED TO WORK BY
THE AGENCY HAVING JURISDICTION.
5. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE REVIEWED AND
APPROVED BY THE AGENCY HAVING JURISDICTION.
6. REFER TO BUILDING ELECTRICAL POWER AND DATA PLANS TO COORDINATE
SYSTEMS AND OTHER FURNITURE WHIP CONNECTIONS. FINAL LOCATIONS OF
FLOOR MOUNTED RECEPTACLES SHALL BE COORDINATED WITH FINAL
FURNITURE SELECTIONS.
7. THE SYSTEMS FURNITURE VENDOR IS RESPONSIBLE FOR PROVIDING POWER
WHIPS AND CONNECTING THEM BY A LICENSED ELECTRICIAN.
8. FURNITURE SYSTEMS VENDOR'S INSTALLATIONS SHALL NOT BE CONSIDERED
COMPLETE UNTIL ALL LAMPS AND ELECTRICAL OUTLETS OPERATE.
9. MANUFACTURER/FURNITURE VENDOR SHALL FIELD VERIFY DIMENSIONS
PRIOR TO PLACING FURNITURE ORDERS AND ARE RESPONSIBLE FOR
COORDINATING CHANGES DUE TO CONFLICTS WITH FIELD CONDITIONS.
VENDOR SHALL COORDINATE HANDED WORKSTATION AND PRIVATE OFFICE
FURNITURE LAYOUTS.
10. REFER TO FURNITURE ILLUSTRATION SHEETS FOR MORE INFORMATION.
FURNITURE CLARIFICATION NOTES
1. THE IF SERIES FURNITURE PLANS ARE FOR USE WITH THE COMPREHENSIVE
INTERIOR DESIGN (CID) PACKAGE FOR FURNITURE PLACEMENT AND
PROCUREMENT.
2. THE IF PLANS SHOW ALL ITEMS INCLUDED IN THE CID PACKAGE AS DASHED AND
TAGGED WITH RESPECTIVE JOINT SCHEDULE NUMBER (JSN) CODES.
3. EQUIPMENT ITEMS NOT INCLUDED IN THE CID PACKAGE ARE SHOWN DASHED AND
WITHOUT JSN CODES. THESE ITEMS ARE SHOWN ON THE IF PLANS FOR
COORDINATION AND SPATIAL RELATIONSHIP ONLY.
4. FOR PLANS NOTING JSN CODES FOR ALL LOGCAT EQUIPMENT ITEMS, REFER TO
THE Q-SERIES EQUIPMENT PLANS.
5. FURNITURE DEALER IS RESPONSIBLE FOR FIELD MEASURING PRIOR TO PLACING
ANY ORDER.
6. DESKS AND WALL MONITORS IN SOLID GREY OUTLINE ARE SHOWN FOR
COORDINATION PURPOSES ONLY AND ARE NOT IN CID PACKAGE. FOR ADDITIONAL
INFORMATION REFER TO TV STUDIO SECTION IN DRAWINGS AND SPECIFICATIONS
APPENDICES.
C
D
B
A
ARCHITECTURE | ENGINEERING
& CONSULTING
3001 WASHINGTON BLVD.
SUITE 200
ARLINGTON, VIRGINIA 22201
703-518-8500
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
NAVFAC DRAWING NO.
ePROJECT NO.:
SCALE:
SHEET OF
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
C
D
B
A
4321 5
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW REV
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
FIRE PROTECTION
As indicated
C rv t\
\A R
-1
-A
-F P
-C -P
-B
J O
S W
A L
D .r v t
/8
/2
:0
:5
P
M
IF-10B-F2
B A
S E
M E
N T
F U
R N
IT
U
R E
P L A
N
A R
E A
F
P H
A S
E
13090156
1171746
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N
A V
F A
C W
A S
H
IN
G T
O N
A T
L A
N T
IC
W
R N
M M
C
B e th e s d a
M
D
N S
A /B e th e s d a M
D B
E T
H E
S D
A M
D
P M
E D
IC
A
L C
E N
T E
R A
D D
IT
IO
N A
L T
E R
A T
IO
N
ROBSON/NOURI
NORTH
P1 Q1 R1 R2
Q2 R4
L2 M4 N3 N4M3
L1 M2 N1 N2M1
H2 J4 K3 K4J3
H1 J2 K1 K2J1
E4 F4 G3 G4F3E3
E2 F2 G1 G2F1E1
B4 C2 D1 D2C1B3
B2B1
A2
A1
KEY PLAN
P H
A S
E
P H
A S
E
D3
Z
R3
1/4" = 1'-0"
FURNITURE PLAN LEVEL B - AREA F2 - PHASE 1
0 2'-0" 4'-0" 8'-0"
H
G
F
GG
HH
STAFF
LOUNGE
BF54
SL001
GENERAL
SUPPLY
BF57
MMGS1
SUPERVISOR,
NETWORK
ADMINISTRATOR
BF73A
OFA03
IT SUPPLY
STORAGE
BF71
SRS01
FILE ROOM,
GENERAL USE
BJ13
FILE1
ADMINISTRATIVE
OFFICER
BF31
OFA02
VI MANAGER
BF28
OFA02
PROJECT
OFFICER
BF27
OFA02
DEPUTY
BF26
OFA02
ADMINISTRATIVE
CUBICLE
BF22E
OFA03
MGAD
STORAGE
BF24
SRSE1
FACILITATOR
BF25
OFA02
ADMINISTRATIVE
CUBICLE
BF22D
OFA03
ADMINISTRATIVE
CUBICLE
BF22A
OFA03
ADMINISTRATIVE
CUBICLE
BF22F
OFA03
CUSTOMER
SERVICE
AREA
BF21
OFA03
COPY ROOM
BJ12
RPR01
N-S
CORRIDOR
LEVEL
BASEMENT PH
BF32
Z1100
CUBICLE
CORRIDOR
BF22
Z9101
CORRIDOR BC
BF03
Z9101
ADMINISTRATIVE
CUBICLE
BF22B
OFA03
MGAD STUDIO
BF23
MIST1
DEPUTY
BF29
OFA02
ADMINISTRATIVE
CUBICLE
BF22C
OFA03
PASSPORT
BE27
OFA02
RECEPTION
BE28
RECP1
E0099M
F0275
F0275
E0099M
F0275
F0275
E0078M1
F0275
F0205M-E
E0820
A6046
F3200
F2000
E0078M2
F0205M-E
F0275
F0205M-E
E0820
A6046
F3200
F2000
E0078M
F0205M-E
F0275
F0205M-E
A6046
F3200
F2000
E0078M2
F0205M-E
F0275
F0205M-E
E0820
A6046
F3200
F2000
E0820
E0078M1
F0275
F2000
F0205M-E F0205M-E
A6046
F3200
F0275
F0205M-E
E0820
A6046
F3200
F2000
E0078M2
F0205M-E
F2005
F0690
F3200
A5155
F0205M-E
E0099M
E0099M
F0205M-E
F0205M-E
F0205M-E
F0205M-E
F3200
E0078M
F0205M-E
A6046
F3200
F0275
F0115
F3050
F0210
F2025
F2025
F2025
F2025
F2000 F2025
F2000 F2025
F2025
F0205M-E
F0205M-E
F2000 F2025
F2000F2025 F2000F2025
F2000 F2025
F2025 F2025 F2025
F0275
F2000
A6046
F0275
E0084
F2000 F2025
F3050
F0420
F3200
F3050
F0415
F0795M2 F0210
F0210
F0210
F2026M
F3010
F2000F2025
F0415
F0415
CORRIDOR BC
BF01
Z9101
STAIR 2
BJST
Z9102
MATCHLINE IF-10B-J1MATCHLINE IF-10B-H1
MATCHLINE IF-10B-E4
MATCHLINE IF-10B-J2.1
MATCHLINE IF-10B-J1
MATCHLINE IF-10B-F4
MATCHLINE IF-10B-E4
MATCHLINE IF-10B-F1MATCHLINE IF-10B-E2
MATCHLINE IF-10B-F4
MATCHLINE IF-10B-F2MATCHLINE IF-10B-F1
F2025
F0465 F0465 F0465
F0415M
F0415M
F0415M
F0420
F0205M-E
F0275
F0205M-E F0205M-E
F0205M-E F0205M-E
F0275F0275
F2025
E0099M
F2000 F2000
F2025
E0099M
E0117
F0275
F2025
F2000
F0275
F2025
F2000
E0117
E0117
F0275 F0275 F0275F2026
F2000
F2025
F0295-BF0295-B
F0415M
E0099M E0099M
F0115F0115F0115F0115
F0275
E0078M1
F0780M
F0780M
U5008U5008
U5008U5008U5008
E0081
F0465M
F0275
PC
CONFIGURATION/
REPAIR AREA
BJ14
BMWS1
F3200
ADMIN OFF
SYST FURN
ADMIN OFF
SYST FURN
BJ11
OFA02
FURNITURE GENERAL NOTES
1. FURNITURE OVER 48" HIGH IS REQUIRED TO BE SEISMICALLY ANCHORED. THIS
WILL INCLUDE, BUT IS NOT LIMITED TO: FILE CABINETS, SHELVING UNITS,
BOOKCASES, AND MODULAR WORK STATION PANELS.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL PRODUCT
SPECIFIC ANCHORAGE DETAILS WITH THE FURNITURE MANUFACTURER.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE LOCATION
OF ALL REQUIRED WALL BACKING AND FLOOR ANCHORS WITH THE
FURNITURE MANUFACTURER.
4. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE STAMPED AND
SIGNED BY A LICENSED STRUCTURAL ENGINEER AUTHORIZED TO WORK BY
THE AGENCY HAVING JURISDICTION.
5. ALL ANCHORAGE DETAILS AND CALCULATIONS SHALL BE REVIEWED AND
APPROVED BY THE AGENCY HAVING JURISDICTION.
6. REFER TO BUILDING ELECTRICAL POWER AND DATA PLANS TO COORDINATE
SYSTEMS AND OTHER FURNITURE WHIP CONNECTIONS. FINAL LOCATIONS OF
FLOOR MOUNTED RECEPTACLES SHALL BE COORDINATED WITH FINAL
FURNITURE SELECTIONS.
7. THE SYSTEMS FURNITURE VENDOR IS RESPONSIBLE FOR PROVIDING POWER
WHIPS AND CONNECTING THEM BY A LICENSED ELECTRICIAN.
8. FURNITURE SYSTEMS VENDOR'S INSTALLATIONS SHALL NOT BE CONSIDERED
COMPLETE UNTIL ALL LAMPS AND ELECTRICAL OUTLETS OPERATE.
9. MANUFACTURER/FURNITURE VENDOR SHALL FIELD VERIFY DIMENSIONS
PRIOR TO PLACING FURNITURE ORDERS AND ARE RESPONSIBLE FOR
COORDINATING CHANGES DUE TO CONFLICTS WITH FIELD CONDITIONS.
VENDOR SHALL COORDINATE HANDED WORKSTATION AND PRIVATE OFFICE
FURNITURE LAYOUTS.
10. REFER TO FURNITURE ILLUSTRATION SHEETS FOR MORE INFORMATION.
FURNITURE CLARIFICATION NOTES
1. THE IF SERIES FURNITURE PLANS ARE FOR USE WITH THE COMPREHENSIVE
INTERIOR DESIGN (CID) PACKAGE FOR FURNITURE PLACEMENT AND
PROCUREMENT.
2. THE IF PLANS SHOW ALL ITEMS INCLUDED IN THE CID PACKAGE AS DASHED AND
TAGGED WITH RESPECTIVE JOINT SCHEDULE NUMBER (JSN) CODES.
3. EQUIPMENT ITEMS NOT INCLUDED IN THE CID PACKAGE ARE SHOWN DASHED AND
WITHOUT JSN CODES. THESE ITEMS ARE SHOWN ON THE IF PLANS FOR
COORDINATION AND SPATIAL RELATIONSHIP ONLY.
4. FOR PLANS NOTING JSN CODES FOR ALL LOGCAT EQUIPMENT ITEMS, REFER TO
THE Q-SERIES EQUIPMENT PLANS.
5. FURNITURE DEALER IS RESPONSIBLE FOR FIELD MEASURING PRIOR TO PLACING
ANY ORDER.
6. DESKS AND WALL MONITORS IN SOLID GREY OUTLINE ARE SHOWN FOR
COORDINATION PURPOSES ONLY AND ARE NOT IN CID PACKAGE. FOR ADDITIONAL
INFORMATION REFER TO TV STUDIO SECTION IN DRAWINGS AND SPECIFICATIONS
APPENDICES.
C
D
B
A
ARCHITECTURE | ENGINEERING
& CONSULTING
3001 WASHINGTON BLVD.
SUITE 200
ARLINGTON, VIRGINIA 22201
703-518-8500
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
NAVFAC DRAWING NO.
ePROJECT NO.:
SCALE:
SHEET OF
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
C
D
B
A
4321 5
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW REV
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
FIRE PROTECTION
As indicated
C rv t\
\A R
-1
-A
-F P
-C -P
-B
J O
S W
A L
D .r v t
/8
/2
:0
:3
P
M
IF-10B-F3
B A
S E
M E
N T
F U
R N
IT
U
R E
P L A
N
A R
E A
F
P H
A S
E
13090157
1171746
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N
A V
F A
C W
A S
H
IN
G T
O N
A T
L A
N T
IC
W
R N
M M
C
B e th e s d a
M
D
N S
A /B e th e s d a M
D B
E T
H E
S D
A M
D
P M
E D
IC
A
L C
E N
T E
R A
D D
IT
IO
N A
L T
E R
A T
IO
N
ROBSON/NOURI
NORTH
P1 Q1 R1 R2
Q2 R4
L2 M4 N3 N4M3
L1 M2 N1 N2M1
H2 J4 K3 K4J3
H1 J2 K1 K2J1
E4 F4 G3 G4F3E3
E2 F2 G1 G2F1E1
B4 C2 D1 D2C1B3
B2B1
A2
A1
KEY PLAN
P H
A S
E
P H
A S
E
D3
Z
R3
1/4" = 1'-0"
FURNITURE PLAN LEVEL B - AREA F3 - PHASE 1
0 2'-0" 4'-0" 8'-0"
G
F
QUARTERDECK
BJ18
LOB01
SEA…