49_21__TFP3.1_Combined_Clinic_TPF_Fire_Suppression_Plan_Phase_1.pdf

PDF 2 MB Posted

Attached to
Tyndall AFB Temporary Modular Medical Facility Federal contract opportunity
Solicitation number
W9127S19Q6039
Issued by
Department of the Army Corps of Engineers Engineering District Little Rock

About this file

Part of Attachment I - As-Builts, 49-TPF Combined

View the file

Other files for this federal contract opportunity

Other files attached to Tyndall AFB Temporary Modular Medical Facility, newest first.
File Type Posted
49_22__TLV2.0_Combined_Clinic_TPF_Low_Voltage_Systems_Notes_&_Details.pdf PDF
1-V1.07_SURVEY_PLAN.pdf PDF
1-V1.02_SURVEY_PLAN.pdf PDF
49_24__TPF2.0_Full_Building_Plan.pdf PDF
49_23__TCP1.4-PII_Combined_Clinic_TPF_RCP-PHASE_II.PDF PDF
1-V1.06_SURVEY_PLAN.pdf PDF
49_24__TPF6.0_Overall_Plumbing_Plan_-_Supply.pdf PDF
49_23__TCP1.1_Combined_Clinic_TPF_RCP.pdf PDF
49_25__TPFV1.0_COVER_SHEET_STAMPED.pdf PDF
49_25__TPFV8.0_CANOPY_ASSEMBLY_AND_FOOTING_DETAILS_STAMPED.pdf PDF
55_TQ3.11D_-_FFE_PLAN_-_TPF_PHASE_1,_AREA_D.pdf PDF
55_TQ4.11_-_FFE_PLAN_-_TPF_PHASE_2.pdf PDF
49_21__TFP1.0_Combined_Clinic_TPF_Life_Safety_Narrative.pdf PDF
49_25__TPFV7.0_RAMP_STEP_AND_PLATFORM_CONNECTION_DETAILS_STAMPED.pdf PDF
1-V1.03_SURVEY_PLAN.pdf PDF
49_23__TCP1.4_Combined_Clinic_TPF_RCP.pdf PDF
1-V1.08_SURVEY_PLAN.pdf PDF
49_21__TFP4.2_Combined_Clinic_TPF_Fire_Alarm_Plan_Phase_2.pdf PDF
49_24__TPF4.0_Overall_Supply_Plumbing_Schematic.pdf PDF
49_24__TPF5.0_Overall_DWV_&_Waste_Schematic.pdf PDF
36_12_TSM1.0_Mechanical_HVAC_Plan.pdf PDF
29_03_TNP4.0_Plumbing_Plan_-_DWV.pdf PDF
29_01_TNC1.0_Cover_Sheet-Notes.pdf PDF
29_03_TNP1.0_Plumbing_Schematics.pdf PDF
43_19_TCCX2.0_Roof_Drain_Details.pdf PDF
43_19_TCCX1.0_Building_Cross_Section.pdf PDF
29_07_TNFD1.0_Foundation_Plan_and_Details.pdf PDF
36_11_TSE1.1_Electrical_Panel_Schedules.pdf PDF
36_10_TSP3.0_Plumbing_Plan_-_Supply_Phase_1.pdf PDF
05_1-CU1.01_UTILITY_PLAN_-_PHASE_1.pdf PDF
43_20_TCCFD1.0_Foundation_Plan_and_Details.pdf PDF
36_09_TSA4.0-PII_Egress_Plan.pdf PDF
07_ES1-01_-_ELECTRICAL_SITE_PLAN_-_MEDICAL_CLINIC_BUILDING_1465.pdf PDF
36_11_TSE3.0-PII_Task_Lighting_Illumination_Plan_Phase_2.pdf PDF
08_T1.10_-_TELECOM_SITE_PLAN_-_CONSTRUCTION_PHASE.pdf PDF
43_17_TCCE2.0_Illumination_Plan.pdf PDF
29_02_TNA2.1_Interior_Elevations.pdf PDF
Attachment_H_-_TPF_Placement_Area.pdf PDF
36_09_TSA4.0_Egress_Plan.pdf PDF
36_08_TSC1.0_Cover_Sheet.pdf PDF
36_11_TSE1.0_Electrical_Plan.pdf PDF
43_18_TCCM1.0_MECHANICAL_HVAC_PLAN.pdf PDF
08_T6.05-TECHNOLOGY_SITE_RISER_DIAGRAM.pdf PDF
36_13_TSX1.0_Building_Cross_Section.pdf PDF
43_15_TCCC1.0_Cover_Sheet_-_Notes.pdf PDF
28_CS.43_-_DWG_INDEX_PKG_I_VOL_3_OF_4.pdf PDF
29_04_TNE1.1_Electrical_Panel_Schedules.pdf PDF
W9127S19Q6039_Tyndall_TMMF_Response_to_Questions_13Aug19.pdf PDF
Attachment_E_-_Installation_Facility_Standards_&_Plans.pdf PDF
Tyndall_TMMF_Statement_of_Work_10Jul19.pdf PDF
Show all 50

Tyndall AFB Temporary Modular Medical Facility has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HAZARD CATAGORY 1 (HC-1)

.10/1500 + 250 HOSE STEAM

ENTIRE BUILDING

HAZARD CATAGORY 2 (HC-2)

.20/2500 + 250 HOSE STEAM

AS NOTED

AREA DESIGN CRITERIA

PER UFC 3-600-01 CHANGE 3

TPF#2

AMBULANCE

SERVICES

TPF#1

PUBLIC

HEALTH

ENTRANCE / EXIT CORRIDOR

UGW UGW

FD SIAMESE WITH

CHECK VALVE AND

AUTOMATIC DRAIN

FORWARD FLOW

TEST HEADER

THROUGH SKIRT

SEE PROJECT

SITE PLAN FOR

CONTINUATION

SPECIFICALLY LISTED CONCEALED SPACE SPRINKLER - THESE SPRINKLERS

MUST BE LOCATED AND INSTALLED IN ACCORDANCE WITH THE LISTING.

SEE DETAIL ON DRAWING FP3.2

30 GAL

W/H

DN

DN

CORRIDOR CORRIDOR

SPRINKLER RISER

LO

C

LO

C

LO

C

NOTE:

CEILING HEIGHT IN "EXCERCISE

AREA" TO BE MINIMUM OF

9'-0"; MODULES "E" & "F" AND

ONLY

NOTE:

CEILING HEIGHT IN "EXCERCISE

AREA" TO BE MINIMUM OF

9'-0"; MODULES "E" & "F" AND

ONLY

A B C D E F G H i J K L M N o P

STORAGE

STAFF

LOUNGE/TEAM

CONFERENCE

ROOM

NCO

OFFICE

(SHARED)

WORKSTATION

WORKSTATION

STORAGE

SHELVING

OFFICE

COMMANDER

ADMIN

OFFICE

MED

RECORDS

WORKSTATION

CONSULT

OFFICE

PERSONAL

PROPERTY

LOCKERS

TREATMENT

AREA/TRACTION

EXERCISE

AREA

PATIENT

TOILET

TREATMENT

CUBICLE

TREATMENT

CUBICLE

STAFF

TOILET JANITOR'S

CLOSET

30 GAL

W/H

STAFF

LOUNGE /

CONFERENCE

ROOM

NCOIC

OFFICE

WAITING

RECEPTION

COPY/FILE

DISTRO

OFFICE

EXAM

ROOM

COMM

ROOM

OFFICE

EXAM

ROOM

APPOINTMENT

CLEARKS

SHIPPING/

RECEIVING

TECHNICAL

SUPERVISOR

SHARED

NCOIC

OFFICE

OIC

OFFICE

CENTRAL

STORAGE

M/TLT

MICRO

BIOLOGY

JANITOR

30 GAL

W/H

F/TLT

SPECIMEN

TOILET

WAITING

RECEPTION

COPY/FILE

DISTRO

TECH

TECH

BLOOD

DRAW AREA

CORE

LAB

STAFF

LOUNGE/TEAM

CONFERENCE

ROOM

SIMULATION

CLASSROOM

CHIEF

ED&T

OFFICE

MDG

COMPUTER

CLASSROOM

MAIN

CLASSROOM

EXERCISE

AREA

B-102

B-104

B-101

S-106

S-105

S-103

S-101d

82.50 SF

S-101a

S-104

S-102 G-109aG-109b

G-103a

178.33 SF

V.C.T.

A-107

G-108

A-106 G-107 G-106

G-102

G-101

G-103

G-103

G-103c V.C.T.

A-101

A-102

G-105

G-104

A-105

A-104

A-103

K-107

K-103

K-104

K-104a

K-101

K-102

K-108 K-109

K-111 K-112

P-106

K-105a

K-105

P-101

A-108

P-102

P-103

STAFF

TOILET

B-103

ON-CALL

ROOM

B-105

KITCHEN

B-104a

S-101c

S-101b

G-103b

G-102a

K-105b

STAFF

TOILET

JANITOR

A-106 K-106

STORAGE

P-105

TECH

OFFICE

A-646

CRUTCH

SPLINT/STO

G-107

OIC

OFFICE

PATIENT

TOILET

30 GAL

W/H C-2

C-2

C-2

C-2

C-2

A-2 A-2

A-2 A-2

B-2

B-2

ON-CALL

ROOM

B-106

S

IN

K

SINK S

IN

K

A B C i K MJ L N o P

MEDICAL

STANDARDS

OFFICE

(MSME)

PROVIDER

OFFICE

PHA

TECHNICIAN

WORKSTATION

PHA

TECHNICIAN

WORKSTATION

NURSE

WORKROOM

SOILED

UTILITY

NCOIC

OFFICE

OIC

OFFICE

PHA

INTERVIEW

ROOM

STAFF

TOILET

JANITOR'S

CLOSET

30 GAL

W/H

ELECTRICAL

ROOM

COMM

ROOM

PHA/DEPLOYMENT

MED/EXAM

ROOM

LPN

OFFICE

NCOIC

OFFICE

OIC

OFFICE

OPTOMETRIST

OFFICE

VISUAL

FIELD

OPTOMETRIST

OFFICE

SUB-WAITING

TOILET

COPY/FILE

DISTRORECEPTIONWAITING

VISUAL

SCREENING

MULTI-DIAGNOSTIC

ROOM

PUBLIC

HEATH

CENTER

AUDIO

TESTINGTECH

OFFICE /

INT OCC

HEALTH

EXAM

ROOM

EXAM

ROOM

IDMT

EXAM

ROOM

EXAM

ROOM

CLEAN

UTILITY

PROVIDER

OFFICE/OICY

PROVIDER

OFFICE

PROVIDER

OFFICE

TECHNOLOGY

OFFICE

STAFF

LOUNGE/TEAM

CONFERENCE

ROOM

TECH

TECH

IDMT

TECH

IDMT

TECH

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

TREATMENT

ROOM

MULTI-DIAGNOSTIC

ROOM

TECH

RECORD

FIXED

SHELVING

TECHNICIAN

OFFICE/INTERVIEW

COMMUNITY

HEALTH

COPY/FILE

DISTRO

DEPLOYMENT

MED OFFICE

COUNSELING

ROOM

TECHNICIAN

OFFICE/INTERVIEW

COMMUNITY

HEALTH

AUDIO

TESTING

FULL

EYE-LANE

FULL

EYE-LANE

FRAMES

CONTACTS

STORAGE

FOLDED

EYE-LANE

FOLDED

EYE-LANE

FITTING

DISPENSING

AREA

MULTI-DIAGNOSTIC

ROOM

WAITING

RECEPTION RECEPTION

COPY/FILE

DISTRO

STORAGE

STAFF

TOILET

PHA

INTERVIEW

ROOM

PHA

INTERVIEW

ROOM

WAITING

TECH

WORKSTATION

CR

C

RCR

CR

C R

CR

CRCR

SUGGESTED SPRINKLER PIPING LAYOUT. THIS LAYOUT IS DIAGRAMMATIC AND MUST BE COORDINATED WITH BUILDING

SERVICES FULL HEIGHT WALLS AND STRUCTURE BY THE INSTALLING CONTRACTOR. THIS LAYOUT DOES NOT PRECLUDE THE

SHOP DRAWING REQUIREMENTS OF UFC3 600-01, 4-1 - SPRINKLER CONTRACTOR IS TO PROVIDE COMPLETE SHOP DRAWINGS

IAW NFPA13 AND SUBMIT TO THE FIRE PROTECTION DOR FOR APPROVAL

0"

'-1

01 2"

'-1 1 2"

'-0

'-1

0"

'-1

'-8

4' -8

8'

-0

'-0

9'

-0

9' -1

1"

4' -8

8'

-0

11'-51 2" 8'-0" 7'-8" 75'-01

2"

'-1

1"

77'-10"

'-0

HYDRAULIC REMOTE AREA

D1

D2

D3

D4

D5

D6

D12

D12

D13

D7

D8

D9

D10

D11

M1 M2 M3 M4

M5

M6

M7

TOR

BOR

HYDRAULIC REMOTE AREA - SYSTEM DEMAND AT BASED OF RISER - 319.39 gpm @ 41.26 ps

DEMAND AT TIE-IN POINT IS 569.39 gpm @50.26 psi.(15.31 psi Cushion at Demand)

All SYSTEM PIPING MUST MATCH SIZES IN REMOTE AREA CALCULATION.

11 2"

4"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2" 11 2"

11 2" 11 2"

11 2" 11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

4" 4" 4" 4" 4" 4" 4" 4" 4"

4" 4" 4"

4"

4"

4' -8

8'

-0

11 2" 11 2"

11 2" 11 2"

11 2"

4' -8

8'

-0

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"8' -1

01 2"

'-7

7' -5

1 2"

'-1

'-3

1 2"

9' -3

'-2

'-4

'-3

9' -3

9' -2

1 2"

9' -1

1 2"

9' -2

9' -1

1 2"

9' -1

1 2"

9' -1

1 2"

8' -2

0'

-1 11 2"

9' -1

1 2"

9' -1

1 2"

'-7

9' -0

7'

-3

9' -0

7' -5

1 2" 1'

-8

7' -3

4'

-7 1 2"

6' -1

1 2" 8'

-0

'-1

0" 9'

-1 0"

3' -5

1 2" 8'

-1 1"

'-9

1 2"

8'-10" 11'-51 2" 12'-0" 10'-0" 7'-3" 6'-9" 9'-11" 5'-111

2" 2'-10" 6'-4" 2'-0" 7'-5" 9'-61 2" 4'-111

2" 4'-4" 9'-4" 9'-41 2" 9'-21

2" 10'-61 2"

'-0

'-0

3' -7

1 2" 4'

-2

'-0

1'

-8

8' -4

3'

-8

6' -8

3'

-4

2' -3

7'

-9

1' -8

8'

-4

'-0

6'

-7

6' -8

2'

-4

7' -8

7'

-9 1 2"

2' -2

1 2"

'-0

'-0

0' -1

0" 2'

-2 1 2"

7' -9

1 2" 1'

-8

0' -1

0" 5'

-2

2' -4

6'

-9

3' -3

3' -4

" 3'-2"

7' -4

2'

-8

6' -8

3'

-4

4' -5

5'

-7

2' -0

8'

-0

'-0

0'

-6

7' -1

0" 2'

-2

'-0

7'

-8

5' -0

7'

-4

0' -8

8' -0

0'

-1

2' -7

2'

-4

7' -8

0'

-7

9' -5

'-0

9' -2

'-0

'-0

3' -8

4'

-0

2' -4

'-0

'-0

9'

-6

'-6

1'

-0 1 2"

8' -1

11 2"

8' -1

1" 1'

-1

6' -5

3'

-7 "0

'-6

7' -2

2'

-4

6' -9

3'

-3

3' -4

1 2" 6'

-7

2' -5

5'

-3

2' -5

1 2" 1'

-7

8' -4

1 2"

'-0

6' -7

3'

-4

3' -4

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2" 11 2"

11 2" 11 2"

11 2"

11 2"

11 2"

11 2"

11 2"

11 2" 11 2" 11 2" 11 2"

11 2"

11 2"11 2" 11 2"

11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2" 11 2"

11 2" 11 2"

11 2" 11 2" 11 2"

11 2"

11 2"

11 2" 11 2"

11 2" 11 2" 11 2"11 2"11 2"

11 2" 11 2"

11 2" 11 2"

11 2"11 2"

11 2" 11 2"

11 2" 11 2" 11 2"

11 2" 11 2" 11 2" 11 2"

11 2" 11 2"

11 2" 11 2" 11 2"

11 2" 11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"11 2"

11 2"

4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4"

2" 11

2" 11 2" 11

2" 11 2" 11

2" 11 2" 11

2" 11 2" 11

2" 11 2"

FIRE SUPPRESSION LEGEND:

PENDANT SPRINKLER - CHROME PLATED SEMI RECESSED

SPECIFIC LISTED CONCEALED SPACE SPRINKLER ABOVE CEILING

54321

54321

/7

/2

:2 :0

P

M

KEY PLAN

N

C O

M B

IN

E

D C

L

IN

IC

T

P F

F

IR

E S

U P

P R

E S

S

IO

N P

L A

N P

H A

S E

T Y

N D

A L L A

F B

TFP3.1

S y m b o l

D es cr ip ti o n

T ra ck in g N o

A ct io n

D at e

L

IT

T L E

R O

C K

D

IV

IS

IO

N

L

IT

T L E

R O

C K

A

R K

A N

S A

S

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

B A

S E

C

IV

IL

E

N G

IN

E

E R

/D E

P U

T Y

C H

IE

F

E N

G

IN

E E

R

IN

G F

L

IG

H T

C

E P

C H

IE

F

C O

N T

R A

C T

S S

E C

T

IO

N

C E

P M

R E

C O

M M

E N

D E

D

R E

C O

M M

E N

D E

D

A P

P R

O V

E D

H O

E F

E R

W Y

S O

C K

I A

R C

H

IT

E C

T S

JE DUNN + HWA

NATIONAL HEALTHCARE DEISGN-BUILD TEAM

TPF FIRE SUPPRESSION PLAN PHASE 1

SCALE: 3 16"=1'-0"N

SEE DRAWING FP-3.3 FOR NOTES AND DETAILS

INDICATES PHASE 2 AREA-

SPRINKLERS WILL BE RELOCATED AS REQUIRED ON FLEXIBLE DROPS OR MAY REMAIN IN PLACE UNLESS THEY ARE <6' APART.

FIRE ALARM DEVICES WILL REMAIN AS INSTALLED.

A s i n d ic a te d

H O

E F

E R

W Y

S O

C K

I

W N

P W

N P

S U

B M

IT

T

A L

C o rr e c te d F in a l

W -1

-R

-6

W -1

-D

-6

R E

V D

A T

E E

N G

IN

E

E R

\D E

S

IG

N E

R

D R

A W

N B

Y

S C

A L E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

C O

N T

R A

C T

N U

M B

E R

D E

S

IG

N T

E A

M J E

D U

N N

U S

IN

G

A G

E N

C Y

C H

E C

K E

D B

Y

/1

/2

U S

A F tracbr Rectangle tracbr Text Box 3/15/2017 tracbr Text Box Amendment 1 tim.kitchens Snapshot

File details come from the government source that posted it.