O V
E R
A L
L D
W V
W
A S
T E
S C
H E
M A
T
IC
TPF-
5.0
A
54321
B
C
D
E
B A
S E
C
IV
IL
E
N G
IN
E
E R
/D E
P U
T Y
C H
IE
F
E N
G
IN
E E
R
IN
G F
L
IG
H T
C
E P
C H
IE
F
C O
N T
R A
C T
S S
E C
T
IO
N
C E
P M
R E
C O
M M
E N
D E
D
R E
C O
M M
E N
D E
D
A P
P R
O V
E D
R E
V D
A T
E E
N G
IN
E
E R
\D E
S
IG
N E
R
D R
A W
N B
Y
S C
A L
E
S O
L
IC
IT
A
T
IO
N N
U M
B E
R
C O
N T
R A
C T
N U
M B
E R
D E
S
IG
N T
E A
M C
E P
M
U S
IN
G
A G
E N
C Y
C H
E C
K E
D B
Y
H O
E F
E R
W Y
S O
C K
I
A R
C H
IT
E
C T
S
3/
/2
JE DUNN + HWA
CLEARWATER, FL 33756
CONSULTING ENGINEER
1765 CARNEGIE AVENUE
Ph: (727) 505-9941
JAMES E. BRADLEY, P.E.
J E B
0' 4' 8' 16' 32'
1/8" = 1'-0"
0' 2' 4' 8' 16'
1/4" = 1'-0"
0' 1' 2'
3/4" = 1'-0"
4'0' 1'
1 1/2" = 1'-0"
2' 2'1'6"6"3"0' 6"
3" = 1'-0"
1'3"
2500 INDUSTRIAL STREET LEESBURG, FL 34748 (352) 728-2930
TPF TYNDALL -
CONNECTING CORRIDOR
T Y
N D
A L
L A
F B
C O
N N
E C
T
IN
G C
O R
R
ID
O R
M
A G
N O
L
IA
C
IR
C L
E T
Y N
D A
L L
A F
B
F L
A S
I N
D
IC
A T
E D
J .L
.B
W
-1
-R -6
W
-1
-D -6
J A
M E
S E
B
R A
D L
E Y
P
.E
J E
D U
N N
S U
B M
IT
T
A L
C O
R R
E C
T E
D F
IN
A
L A
M E
N D
M E
N T
J .E
.B
& ASSOCIATES
HILBORN, WERNER, CARTER
1627 SOUTH MYRTLE AVE.
CLEARWATER, FLORIDA 33756
THIRD PARTY:
S y m b o l
D es cr ip ti o n T ra ck in g N o
A ct io n
D at e
TPF TYNDALL - NORTH
PUBLIC HEALTH BLDG
TPF TYNDALL - SOUTH
AMBULANCE SERVICES BLDG
MODULE P
REFERENCE UTILITY
PLAN 1-CU1.01 FOR
ADDITIONAL WASTE
PIPING INFORMATION
MODULE
PERIMETER
MODULE A
MODULE B
MODULE C
MODULE D
MODULE E
MODULE F
MODULE G
MODULE
MATELINE
MODULE H
MODULE I
MODULE J
MODULE K
MODULE L
MODULE M
MODULE N
MODULE O
MODULE P
MODULE A
MODULE B
MODULE C
MODULE D
MODULE E
MODULE F
MODULE G
MODULE H
MODULE I
MODULE J
MODULE K
MODULE L
MODULE M
MODULE N
MODULE O
MODULE P
MODULE
PERIMETER
MODULE A
MODULE B
MODULE C
MODULE D
MODULE E
MODULE F
MODULE G
MODULE
MATELINE
MODULE H
MODULE I
MODULE J
MODULE K
MODULE L
MODULE M
MODULE N
MODULE O
MODULE P
MODULE A
MODULE B
MODULE C
MODULE D
MODULE E
MODULE F
MODULE G
MODULE H
MODULE I
MODULE J
MODULE K
MODULE L
MODULE M
MODULE N
MODULE O
MODULE P
6" DRAIN
3" DRAIN
3" DRAIN
1 1
2" VTR
1 1 2"
2" D
RAIN
2" D
RAIN
LAV
1 1 2"
1 1 2" A.V.
SINK
1 1 2"
1 1
2" VTR
1 1 2"
1 1 2"
SINK
1 1 2"
2" D
RAIN
1 1
2" VTR
1 1 2"
2" D
RAIN
LAV
1 1 2"
1 1
2" VTR
1 1 2"
LAV
1 1 2"
1 1
2" VTR
1 1 2"
2" D
RAIN
LAV
1 1 2"
1 1
2" VTR
1 1 2"
LAV
1 1 2"
2" D
RAIN
1 1
2" VTR
1 1
2" LAV
1 1 2"
1 1
2" VTR
1 1 2"
LAV
1 1 2"
1 1
2" VTR
1 1 2"
2" D
RAIN
WF
1 1 2"
3" VTR
3"
WC
LAV
1 1 2"
3"
3" WC
LAV
1 1 2"
1 1/2" B V
3" D
RAIN
3" D
RAIN
1 1
2" VTR
1 1 2"
1 1 2"
2" D
RAIN
LAV
1 1 2"
2" D
RAIN
1 1
2" VTR
1 1
2" LAV
1 1 2"
2" D
RAIN
1 1
2" VTR
1 1
2" LAV
1 1
2"LAV
1 1 2"
4" D
RAIN
1 1
2" VTR
1 1
2" LAV
1 1 2"
3" VTR
3"
WC
3"
LAV
1 1 2"
3"
3" D
RAIN
2" VTR
2"
3" D
RAIN
MOP
SINK
2" 3"
LAV
1 1 2"
1 1 2"
1 1 2"
1 1
2" VTR
1 1
2" VTR
1 1 2"
LAV
3"C.O.
3" DRAIN
3"C.O.
2" D
RAIN
3" DRAIN
3" DRAIN
3" DRAIN
3" DRAIN
4" DRAIN
4" DRAIN
4" DRAIN
4" D
RAIN
FD
3"
3"
3" D
RAIN
F.D.
3"
3"
F.D.
3" F.D.
4"C.O.
4" DRAIN
3" D
RAIN
3" DRAIN
3" VTR
3"
SINK
1 1 2"
3"
SHOWER
2"
2" VTR
2"
WC
3"
1 1
2" VTR
1 1 2"
1 1/2" D
RAIN
SINK
1 1 2"
3" VTR
3"
3"
WC
3"
LAV
1 1 2"
3" VTR
3"
3"
WC
3"
LAV
1 1 2"
3"
3" D
RAIN
3"
1 1/2"
VTR
SHOWER
LAV
2"
2"
2"
1 1 2"
1 1
2" VTR
1 1 2"
SINK
1 1 2"
1 1 2"
3" VTR
3"
WC 3"
LAV
1 1 2"
3"
3"
3" D
RAIN
1 1
2" VTR
1 1 2"
MOP
SINK
2"
3"
1 1/2" D
RAIN
1 1
2" VTR
1 1 2"
LAV
1 1 2"
1 1
2" VTR
1 1 2"
LAV
1 1 2"
1 1/2" D
RAIN
3" VTR
3"
2" B V
WC
3"
3"
URINAL
URINAL
2"
2"
2"
2"
2" VTR
2" 2" B
V
2"
2"
LAV
1 1
2"
LAV
1 1 2"
MOP
SINK
2"
2"
2"
LAV
1 1
2"
LAV
1 1 2"
2" B V
3" VTR
3"
WC
3"
3"
2"
WC
3" 3"
WC
3"
2" B V
WC
3"
LAV
1 1 2"
1 1
2" VTR
1 1 2"
1 1 2"
LAV
1 1 2"
1 1
2" VTR
2"
1 1 2"
MOP
SINK
1 1/2"
SINK
1 1 2" A.V.
2"
WC 3"
LAV
1 1 2" 3"
3"
1 1/2"
SINK
2" D
RAIN
3" DRAIN
4" DRAIN
4" DRAIN
4" DRAIN
4" D
RAIN
C.O.
STAINLESS STEEL
WALL MOUNTED
HAND SINK
1 1/2"
SINK
1 1
2" A.V.
4" D
RAIN
3"
F.D.
3"
2"B.V.
3" VTR
3"
FD
4"C O
3"
3" D
RAIN
2" D
RAIN
FD
FD
3" D
RAIN
3" D
RAIN
3" D
RAIN
3" D
RAIN
3" D
RAIN
4"C.O.
4" DRAIN
1 1 2"
FD
3"
3"
FD
3"
3"
3" D
RAIN
1 1/2" D
RAIN
1 1/2" D
RAIN
1 1/2" D
RAIN
3" DRAIN
3" DRAIN
3" DRAIN1 1
2" VTR
1 1 2"
1 1
2" VTR
1 1 2"
1 1 2"
3" D
RAIN
2" VTR
2"
3"
F.D.
3"
3"
F.D.
SINK
SINK
1 1/2"
1 1/2"
1 1/2" tim.kitchens Snapshot