49_21__TFP3.2_Combined_Clinic_TPF_Fire_Suppression_Plan_Phase_2.pdf

PDF 2 MB Posted

Attached to
Tyndall AFB Temporary Modular Medical Facility
Solicitation number
W9127S19Q6039
Issued by

About this file

Part of Attachment I - As-Builts, 49-TPF Combined

View the file

Other files

File Type Posted
49_22__TLV2.0_Combined_Clinic_TPF_Low_Voltage_Systems_Notes_&_Details.pdf PDF
55_TQ3.11A_-_FFE_PLAN_-_TPF_PHASE_1,_AREA_A.pdf PDF
49_21__TFP1.0_Combined_Clinic_TPF_Life_Safety_Narrative.pdf PDF
49_25__TPFV5.0_STANDARD_CANOPY_DETAILS_STAMPED.pdf PDF
49_25__TPFV3.0_STANDARD_RAMP_AND_STAIR_DETAILS_STAMPED.pdf PDF
49_24__TPF2.1-P2_Full_Building_Plan_Phase_2.pdf PDF
1-V1.03_SURVEY_PLAN.pdf PDF
49_21__TFP2.0_Combined_Clinic_TPF_Life_Safety_Plan.pdf PDF
1-V1.01_SURVEY_PLAN.pdf PDF
49_23__TCP1.4_Combined_Clinic_TPF_RCP.pdf PDF
1-V1.04_SURVEY_PLAN.pdf PDF
55_TQ3.11B_-_FFE_PLAN_-_TPF_PHASE_1,_AREA_B.pdf PDF
49_21__TFP3.3_Combined_Clinic_TPF_Fire_Suppression_Notes_and_Details.pdf PDF
49_23__TCP1.0_Combined_Clinic_TPF_RCP.pdf PDF
49_24__TPF3.0_Full_Luminary_Plan.pdf PDF
56_SGT.02_TEMP_SIGNAGE_TPF_PHASE_1.pdf PDF
49_22__TLV1.0_Combined_Clinic_TPF_LV_Systems_Notes_&_Details.pdf PDF
55_TQ3.01_-_FFE_JSN_LEGEND.pdf PDF
49_25__TPFV6.0_CANOPY_FOOTING_DETAILS_STAMPED.pdf PDF
49_24__TPF4.0_Overall_Supply_Plumbing_Schematic.pdf PDF
1-V1.08_SURVEY_PLAN.pdf PDF
55_TQ3.11C_-_FFE_PLAN_-_TPF_PHASE_1,_AREA_C.pdf PDF
49_24__TPF2.0-PI_Full_Building_Plan-Phase_1.pdf PDF
49_25__TPFV2.0_STANDARD_RAMP_AND_STAIR_DETAILS_STAMPED.pdf PDF
49_23__TCP1.3_Combined_Clinic_TPF_RCP.pdf PDF
55_TQ4.11D_-_FFE_PLAN_-_TPF_PHASE_2,_AREA_D.pdf PDF
1-V1.05_SURVEY_PLAN.pdf PDF
49_23__TCP1.5_Combined_Clinic_TPF_RCP.pdf PDF
55_TQ4.11C_-_FFE_PLAN_-_TPF_PHASE_2,_AREA_C.pdf PDF
49_23__TCP1.2_Combined_Clinic_TPF_RCP.pdf PDF
55_TQ3.11_-_FFE_PLAN_-_TPF_PHASE_1.pdf PDF
49_21__TFP4.3_Combined_Clinic_TPF_Fire_Alarm_Details_and_Notes.pdf PDF
55_TQ4.01_-_FFE_JSN_LEGEND.pdf PDF
49_23__TCP1.4-PI_Combined_Clinic_TPF_RCP-PHASE_1.pdf PDF
49_21__TFP4.2_Combined_Clinic_TPF_Fire_Alarm_Plan_Phase_2.pdf PDF
49_24__TPF5.0_Overall_DWV_&_Waste_Schematic.pdf PDF
56_SGT.03_TEMP_SIGNAGE_TPF_PHASE_2.pdf PDF
49_25__TPFV4.0_STANDARD_RAMP_AND_STAIR_DETAILS_STAMPED.pdf PDF
49_21__TFP4.1_Combined_Clinic_TPF_Fire_Alarm_Plan_Phase_1.pdf PDF
49_25__TPFV7.0_RAMP_STEP_AND_PLATFORM_CONNECTION_DETAILS_STAMPED.pdf PDF
55_TQ3.02_-_FFE_JSN_LEGEND.pdf PDF
49_24__TPF1.0_Full_Building_Elevations.pdf PDF
49_24__TPF7.0_Overall_Plumbing_Plan_-_D.W.V.pdf PDF
55_TQ3.11D_-_FFE_PLAN_-_TPF_PHASE_1,_AREA_D.pdf PDF
49_23__TCP1.4-PII_Combined_Clinic_TPF_RCP-PHASE_II.PDF PDF
1-V1.06_SURVEY_PLAN.pdf PDF
49_23__TCP1.1_Combined_Clinic_TPF_RCP.pdf PDF
49_25__TPFV8.0_CANOPY_ASSEMBLY_AND_FOOTING_DETAILS_STAMPED.pdf PDF
49_21__TFP3.1_Combined_Clinic_TPF_Fire_Suppression_Plan_Phase_1.pdf PDF
1-V1.02_SURVEY_PLAN.pdf PDF
Show 40 more

Latest 50 of 129 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HAZARD CATAGORY 1 (HC-1)

.10/1500 + 250 HOSE STEAM

ENTIRE BUILDING

HAZARD CATAGORY 2 (HC-2)

.20/2500 + 250 HOSE STEAM

AS NOTED

AREA DESIGN CRITERIA

PER UFC 3-600-01 CHANGE 3

TPF#2

AMBULANCE

SERVICES

TPF#1

PUBLIC

HEALTH

ENTRANCE / EXIT CORRIDOR

FD SIAMESE WITH

CHECK VALVE AND

AUTOMATIC DRAIN

FORWARD FLOW

TEST HEADER

THROUGH SKIRT

SEE PROJECT

SITE PLAN FOR

CONTINUATION

SPECIFICALLY LISTED CONCEALED SPACE SPRINKLER - THESE SPRINKLERS

MUST BE LOCATED AND INSTALLED IN ACCORDANCE WITH THE LISTING.

SEE DETAIL ON DRAWING FP3.2

A B C D G i K ME F H J L N o P

MEDICAL

STANDARDS

OFFICE

(MSME)

PROVIDER

OFFICE

PHA

TECHNICIAN

WORKSTATION

PHA

TECHNICIAN

WORKSTATION

NURSE

WORKROOM

SOILED

UTILITY

NCOIC

OFFICE

NCOIC

OFFICE

PHA

INTERVIEW

ROOM

STAFF

TOILET

JANITOR'S

CLOSET

30 GAL

W/H

ELECTRICAL

ROOM

COMM

ROOM

PHA/DEPLOYMENT

MED/EXAM

ROOM

LPN

OFFICE

NCOIC

OFFICE

OIC

OFFICE

OPTOMETRIST

OFFICE

VISUAL

FIELD

OPTOMETRIST

OFFICE

SUB-WAITING

TOILET

COPY/FILE

DISTRORECEPTIONWAITING

VISUAL

SCREENING

MULTI-DIAGNOSTIC

ROOM

PUBLIC

HEATH

CENTER

AUDIO

TESTINGTECH

OFFICE /

INT OCC

HEALTH

EXAM

ROOM

EXAM

ROOM

IDMT

EXAM

ROOM

EXAM

ROOM

CLEAN

UTILITY

PROVIDER

OFFICE/OICY

PROVIDER

OFFICE

PROVIDER

OFFICE

TECHNOLOGY

OFFICE

STAFF

LOUNGE/TEAM

CONFERENCE

ROOM

TECH

TECH

IDMT

TECH

IDMT

TECH

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

TREATMENT

ROOM

MULTI-DIAGNOSTIC

ROOM

TECH

RECORD

FIXED

SHELVING

TECHNICIAN

OFFICE/INTERVIEW

COMMUNITY

HEALTH

COPY/FILE

DISTRO

DEPLOYMENT

MED OFFICE

COUNSELING

ROOM

TECHNICIAN

OFFICE/INTERVIEW

COMMUNITY

HEALTH

AUDIO

TESTING

FULL

EYE-LANE

FULL

EYE-LANE

FRAMES

CONTACTS

STORAGE

FOLDED

EYE-LANE

FOLDED

EYE-LANE

FITTING

DISPENSING

AREA

MULTI-DIAGNOSTIC

ROOM

WAITING

RECEPTION RECEPTION

COPY/FILE

DISTRO

STORAGE

STAFF

TOILET

PHA

INTERVIEW

ROOM

PHA

INTERVIEW

ROOM

DN

DN

CORRIDOR CORRIDOR

SPRINKLER RISER

LO

C

LO

C

LO

C

NOTE:

CEILING HEIGHT IN "EXCERCISE

AREA" TO BE MINIMUM OF

9'-0"; MODULES "E" & "F" AND

ONLY

NOTE:

CEILING HEIGHT IN "EXCERCISE

AREA" TO BE MINIMUM OF

9'-0"; MODULES "E" & "F" AND

ONLY

A B C D E F G H i J K L M N o P

STORAGE

STAFF

LOUNGE/TEAM

CONFERENCE

ROOM

NCO

OFFICE

(SHARED)

PERSONAL

PROPERTY

LOCKERS

PATIENT

TOILET

STAFF

TOILET JANITOR'S

CLOSET

30 GAL

W/H

STAFF

LOUNGE /

CONFERENCE

ROOM

WAITING

COMM

ROOM

SHIPPING/

RECEIVING

TECHNICAL

SUPERVISOR

SHARED

NCOIC

OFFICE

OIC

OFFICE

CENTRAL

STORAGE

M/TLT

MICRO

BIOLOGY

JANITOR

30 GAL

W/H

F/TLT

SPECIMEN

TOILET

WAITING

RECEPTION

COPY/FILE

DISTRO

TECH

TECH

BLOOD

DRAW AREA

CORE

LAB

STAFF

LOUNGE/TEAM

CONFERENCE

ROOM

FIT

B-102

B-104

B-101

S-102 G-109aG-109b

A-107

G-108

A-106 G-107 G-106

G-101

G-103

G-103

A-102

G-104

A-105

A-104

A-103

K-107

K-103

K-104

K-104a

K-101

K-102

K-108 K-109

K-111 K-112

P-106

K-105a

K-105

P-101

A-108

P-103

STAFF

TOILET

B-103

ON-CALL

ROOM

B-105

KITCHEN

B-104a

K-105b

STAFF

TOILET

JANITOR

A-106 K-106

P-105

TECH

OFFICE

A-646

CRUTCH

SPLINT/STO

G-107

PATIENT

TOILET

30 GAL

W/H

A-2

C-2 C-2

E-2

E-2

ON-CALL

ROOM

B-106 S

IN

K

SINK S

IN

K

S O S

HSMR

STORAGE

STORAGE

/0 x

/8

C

3/0x6/8

C

747.40 SF

V.C.T.

168.42 SF

V.C.T.

FIT

170.00 SF

V.C.T.

LIBRARY

V.C.T.

3/0x6/8

C

OFFICEOFFICE

STORAGE

BEE

WORK ROOM

OFFICE

LAB

VACANTVACANT

BMET

VACANT

VACANT

VACANT

VACANT

VACANT

A-2A-2

A-2A-2

A-2

A-2

A-2

A-2

A-2

CFM

J

CR

C

RCR

CR

C R

CR

CRCR

SUGGESTED SPRINKLER PIPING LAYOUT. THIS LAYOUT IS DIAGRAMMATIC AND MUST BE COORDINATED WITH BUILDING

SERVICES FULL HEIGHT WALLS AND STRUCTURE BY THE INSTALLING CONTRACTOR. THIS LAYOUT DOES NOT PRECLUDE THE

SHOP DRAWING REQUIREMENTS OF UFC3 600-01, 4-1 - SPRINKLER CONTRACTOR IS TO PROVIDE COMPLETE SHOP DRAWINGS

IAW NFPA13 AND SUBMIT TO THE FIRE PROTECTION DOR FOR APPROVAL

UGW UGW

'-1

01 2"

'-1 1 2"

'-0

'-1

0"

'-1

'-8

4' -8

8'

-0

'-0

9'

-0

9' -1

1"

4' -8

8'

-0

11'-51 2" 8'-0" 7'-8" 75'-01

2"

'-1

1"

77'-10"

'-0

11 2"

4"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2" 11 2"

11 2" 11 2"

11 2" 11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

4" 4" 4" 4" 4" 4" 4" 4" 4"

4" 4" 4"

4"

4"

4' -8

8'

-0

11 2" 11 2"

11 2" 11 2"

11 2"

4' -8

8'

-0

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2"8' -1

01 2"

'-7

7' -5

1 2"

'-1

'-3

1 2"

9' -3

'-2

'-4

'-3

9' -3

9' -2

1 2"

9' -1

1 2"

9' -2

9' -1

1 2"

9' -1

1 2"

9' -1

1 2"

8' -2

0'

-1 11 2"

9' -1

1 2"

9' -1

1 2"

'-7

9' -0

7'

-3

9' -0

7' -5

1 2" 1'

-8

7' -3

4'

-7 1 2"

6' -1

1 2" 8'

-0

'-1

0" 9'

-1 0"

3' -5

1 2" 8'

-1 1"

'-9

1 2"

8'-10" 11'-51 2" 12'-0" 10'-0" 7'-3" 6'-9" 9'-11" 5'-111

2" 2'-10" 6'-4" 2'-0" 7'-5" 9'-61 2" 4'-111

2" 4'-4" 9'-4" 9'-41 2" 9'-21

2" 10'-61 2"

'-0

'-0

3' -7

1 2" 4'

-2

'-0

1'

-8

8' -4

3'

-8

6' -8

3'

-4

2' -3

7'

-9

1' -8

8'

-4

'-0

6'

-7

6' -8

2'

-4

7' -8

7'

-9 1 2"

2' -2

1 2"

'-0

'-0

0' -1

0" 2'

-2 1 2"

7' -9

1 2" 1'

-8

0' -1

0" 5'

-2

2' -4

6'

-9

3' -3

3' -4

" 3'-2"

7' -4

2'

-8

6' -8

3'

-4

4' -5

5'

-7

2' -0

8'

-0

'-0

0'

-6

7' -1

0" 2'

-2

'-0

7'

-8

5' -0

7'

-4

0' -8

8' -0

0'

-1

2' -7

2'

-4

7' -8

0'

-7

9' -5

'-0

9' -2

'-0

'-0

3' -8

4'

-0

2' -4

'-0

'-0

9'

-6

'-6

1'

-0 1 2"

8' -1

11 2"

8' -1

1" 1'

-1

6' -5

3'

-7 "0

'-6

7' -2

2'

-4

6' -9

3'

-3

3' -4

1 2" 6'

-7

2' -5

5'

-3

2' -5

1 2" 1'

-7

8' -4

1 2"

'-0

6' -7

3'

-4

3' -4

11 2" 11 2"

11 2" 11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2" 11 2"

11 2" 11 2"

11 2"

11 2"

11 2"

11 2"

11 2"

11 2" 11 2" 11 2" 11 2"

11 2"

11 2"11 2" 11 2"

11 2"

11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2" 11 2"

11 2" 11 2"

11 2" 11 2" 11 2"

11 2"

11 2"

11 2" 11 2"

11 2" 11 2" 11 2"11 2"11 2"

11 2" 11 2"

11 2" 11 2"

11 2"11 2"

11 2" 11 2"

11 2" 11 2" 11 2"

11 2" 11 2" 11 2" 11 2"

11 2" 11 2"

11 2" 11 2" 11 2"

11 2" 11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"

11 2" 11 2"11 2"

11 2"

4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4"

2" 11

2" 11 2" 11

2" 11 2" 11

2" 11 2" 11

2" 11 2" 11

2" 11 2"

FIRE SUPPRESSION LEGEND:

PENDANT SPRINKLER - CHROME PLATED SEMI RECESSED

SPECIFIC LISTED CONCEALED SPACE SPRINKLER ABOVE CEILING

54321

54321

/7

/2

:2 :0

P

M

KEY PLAN

N

C O

M B

IN

E

D C

L

IN

IC

T

P F

F

IR

E S

U P

P R

E S

S

IO

N P

L A

N P

H A

S E

T Y

N D

A L L A

F B

TFP3.2

S y m b o l

D es cr ip ti o n

T ra ck in g N o

A ct io n

D at e

L

IT

T L E

R O

C K

D

IV

IS

IO

N

L

IT

T L E

R O

C K

A

R K

A N

S A

S

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

B A

S E

C

IV

IL

E

N G

IN

E

E R

/D E

P U

T Y

C H

IE

F

E N

G

IN

E E

R

IN

G F

L

IG

H T

C

E P

C H

IE

F

C O

N T

R A

C T

S S

E C

T

IO

N

C E

P M

R E

C O

M M

E N

D E

D

R E

C O

M M

E N

D E

D

A P

P R

O V

E D

H O

E F

E R

W Y

S O

C K

I A

R C

H

IT

E C

T S

JE DUNN + HWA

NATIONAL HEALTHCARE DEISGN-BUILD TEAM

SEE DRAWING FP-3.3 FOR NOTES AND DETAILS

A s i n d ic a te d

H O

E F

E R

W Y

S O

C K

I

W N

P W

N P

S U

B M

IT

T

A L

C o rr e c te d F in a l

W -1

-R

-6

W -1

-D

-6

R E

V D

A T

E E

N G

IN

E

E R

\D E

S

IG

N E

R

D R

A W

N B

Y

S C

A L E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

C O

N T

R A

C T

N U

M B

E R

D E

S

IG

N T

E A

M J E

D U

N N

U S

IN

G

A G

E N

C Y

C H

E C

K E

D B

Y

/1

/2

U S

A F

N

INDICATES PHASE 2 AREA-

SPRINKLERS WILL BE RELOCATED AS REQUIRED ON FLEXIBLE DROPS OR MAY REMAIN IN PLACE UNLESS THEY ARE <6' APART.

FIRE ALARM DEVICES WILL REMAIN AS INSTALLED.

N

INDICATES PHASE 2 AREA-

SPRINKLERS WILL BE RELOCATED AS REQUIRED ON FLEXIBLE DROPS OR MAY REMAIN IN PLACE UNLESS THEY ARE <6' APART.

FIRE ALARM DEVICES WILL REMAIN AS INSTALLED.

TPF FIRE SUPPRESSION PLAN PHASE 2

SCALE: 3 16"=1'-0"N

INDICATES PHASE 2 AREA-

SPRINKLERS WILL BE RELOCATED AS REQUIRED ON FLEXIBLE DROPS OR MAY REMAIN IN PLACE UNLESS THEY ARE <6' APART.

FIRE ALARM DEVICES WILL REMAIN AS INSTALLED.