Text version
O V
E R
A
LL
S U
P P
LY
P
LU
M
B
IN
G S
C H
E M
A
TI
C
TPF-
4.0
A
54321
B
C
D
E
B A
S E
C
IV
IL
E
N G
IN
EE
R /D
EP
U
TY
C H
IE
F
E N
G
IN
E E
R
IN
G F
LI
G
H T
(C
EP
C H
IE
F
C O
N
TR
AC
TS
S
EC
TI
O
N (C
EP
M
R
EC
O M
M E
N D
ED
R
EC
O M
M E
N D
ED
A P
P R
O
VE
D
E N
G
IN
E E
R \D
ES
IG
N
ER
D R
A W
N B
Y
S C
A
LE
D
AT
E
R
EV
3/
/2
S O
LI
C
IT
AT
IO
N
N U
M B
ER
C O
N
TR
AC
T
N U
M
BE
R D
ES
IG
N T
E
AM
C
EP
M
U S
IN
G
A G
EN
C
Y
C H
E C
K
ED
B Y
H O
EF
ER
W
YS
O C
K I
A R
C H
IT
EC
TS
JE DUNN + HWA
CLEARWATER, FL 33756
CONSULTING ENGINEER
1765 CARNEGIE AVENUE
Ph: (727) 505-9941
JAMES E. BRADLEY, P.E.
J E B
0' 4' 8' 16' 32' 1/8" = 1'-0"
0' 2' 4' 8' 16' 1/4" = 1'-0"
0' 1' 2' 3/4" = 1'-0"
4'0' 1' 1 1/2" = 1'-0"
2' 2'1'6"6"3"0' 6" 3" = 1'-0"
1'3"
2500 INDUSTRIAL STREET LEESBURG, FL 34748 (352) 728-2930
TPF TYNDALL -
CONNECTING CORRIDOR
TY
N
D A
LL
A
FB
C
O N
N E
C
TI
N G
C O
R R
ID
O
R
M
A G
N O
LI
A
C
IR
C
LE
T
YN
D
AL
L A
FB
, F
L
A S
IN
D
IC
AT
ED
J.
L.
B.
W
5-
-R -6
W
5-
-D
-6
JA
M
E S
E . B
R A
D
LE
Y, P
.E
JE
D
U N
N
S U
B M
IT
TA
L #4
C
O R
R E
C
TE
D F
IN
A
L A
M E
N D
M E
N T
J.
E
.B
Sy m bo l
D es cr ip tio n
Tr ac ki ng
N o.
A ct io n
D at e
TPF TYNDALL - NORTH
PUBLIC HEALTH BLDG
TPF TYNDALL - SOUTH
AMBULANCE SERVICES BLDG
MODULE A
MODULE B
MODULE C
MODULE D
MODULE E
MODULE F
MODULE G
MODULE H
MODULE I
MODULE J
MODULE K
MODULE L
MODULE M
MODULE N
MODULE O
MODULE P
MODULE
PERIMETER
MODULE A
MODULE B
MODULE C
MODULE D
MODULE E
MODULE F
MODULE G
MODULE
MATELINE
MODULE H
MODULE I
MODULE J
MODULE K
MODULE L
MODULE M
MODULE N
MODULE O
MODULE P
MODULE A
MODULE B
MODULE C
MODULE D
MODULE E
MODULE F
MODULE G
MODULE H
MODULE I
MODULE J
MODULE K
MODULE L
MODULE M
MODULE N
MODULE O
MODULE P
REFERENCE UTILITY
PLAN 1-CU1.01 FOR
ADDITIONAL WASTE
PIPING INFORMATION
SUPPLY LINE NOTES:
1. SUPPLY LINE SIZING IS BASED ON AN ASSUMED AVAILABLE PRESSURE OF
60 PSI AT THE LOCATION OF THE INLET(S) SHOWN AFTER ANY DEDUCTIONS
FOR PRESSURE LOSS DUE TO METER, TAP INTO MAIN, WATER PRESSURE
REDUCING VALVES, SPECIAL EQUIPMENT SUCH AS BACKFLOW PREVENTOR,
FILTER, SOFTENER, ETC. THIS AVAILABLE PRESSURE MUST BE VERIFIED
PRIOR TO CONSTRUCTION. IF A BOOSTER PUMP IS NEEDED TO ACHIEVE
REQUIRED PRESSURE THEN THE BUILDING OWNER IS RESPONSIBLE FOR
DESIGN AND INSTALLATION OF PUMP SYSTEM.
2. SUPPLY LINE INLET(S) SHOWN ON THESE PLANS ARE ASSUMED TO
EXTEND ONLY TO EXTERIOR WALL. ALL SERVICE SUPPLY LINES UP TO THE
INLET(S) ARE DESIGNED BY OTHERS AND SITE INSTALLED UNLESS
OTHERWISE SPECIFIED.
3. SUPPLY LINE SIZING MUST BE REDESIGNED IF THE BUILDING DOES NOT
COMPLY WITH ANY OF THE ABOVE ASSUMPTIONS.
4. UNLESS OTHERWISE SPECIFIED ALL SUPPLY LINES ARE 1"Ø MINIMUM TO
FLUSHOMETER VALVE WATER CLOSETS AND 3/4"Ø MINIMUM TO ALL
OTHER FIXTURES. UNLESS OTHERWISE SPECIFIED ALL STUB-UPS ARE 1"Ø TO
FLUSHOMETER WATER CLOSETS, 3/4"Ø TO FLUSH VALVE URINALS AND
1/2"Ø TO ALL OTHER FIXTURES.
5. EACH URINAL SHALL NOT REQUIRE MORE THAN 15 PSI OF PRESSURE (12
GPM) TO ACTIVATE THE FLUSHOMETER VALVE.
6. EACH WATER CLOSET SHALL NOT REQUIRE MORE THAN 25 PSI OF
PRESSURE (25 GPM) TO ACTIVATE THE FLUSHOMETER VALVE.60 PSI AT MAIN INLET AND SHOULD BE VERIFIED
AN ASSUMED AVAILABLE PRESSURE OF 46 TO
SPECIFIED. SUPPLY LINE SIZING IS BASED ON
PRIOR TO CONSTURCTION.
STUB-UPS SHALL BE 1/2" UNLESS OTHERWISE
ALL SUPPLY LINES SHALL BE 3/4" AND ALL
SUPPLY RISER
COLD
HOT
SCALE: N.T.S.
SINK
SHOWER
SINK
WC
LAV
LAV SHOWER
LAV
SINK
WC
LAV
MOP
SINK
LAV
LAV
WC
URINAL
URINAL
LAV
LAV MOP
SINK
LAV
WC
WC
WC
WCLAV
LAV
MOP
SINK
SINK
SINK
SINK
SINK
LAV
1/2"
1/ 2"
1/ 2"
1/ 2"
WC
F.D.
w/T.P. 1/2"
3/4"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
LAV
F.D.
w/T.P.
F.D.
w/T.P.
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"1/
2"
1/ 2"
1/ 2"
1/ 2"
1/ 2" 1/
2"1/ 2"
1/ 2"
1/ 2"
1/ 2"
3/ 4"
3/ 4"
1/ 2" 3/4"
1/2"
3/4"
1" 1/2"
3/4"
3/4"
3/4"
3/4"
1/2"
1"
1"
1"
1/ 2"
1/ 2"
1/ 2"
1/ 2" 1/2"1/2"
1/2"1/2"
F.D.
w/T.P.
F.D.
w/T.P.
3/4" 3/4"
3/4"
3/4" 3/4"
3/4" 3/4"
3/4"
3/4"
1/2"
F.D.
w/T.P.
1" 1"
3/4" 3/4"
1" 1"
1/ 2"1/
2"1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2" 1/
2"
1/ 2"
1/ 2"
1/2"1/2"
WC
3/4"
3/4" 3/4"
1/2"
1/ 2"1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
3/4"3/4"
3/4"3/4"
3/4"1"
1"
VALVE
T&P
30 GAL.
W/H
1"
VALVE
T&P
30 GAL.
W/H
3/4"
3/4"
3/4"
3/4"
3/4"
1/2"3/4" 1"
1/2"
1 1/4"
1 1/4"
1 1/4"
1 1/4"
1 1/4"
1 1/4"
1 1/4"
1 1/4"
1/2" 1/2"
1"
3/ 4"
3/ 4"
VALVE
T&P
30 GAL.
W/H
1/2"
1/2"
3/4"
3/4"
3/4"3/4"
3/4"
1/2"
3/4"
1/2"
REFERENCE TPF-5.0
FOR OVERALL WASTE
PIPING ISOMETRIC
STAINLESS
STEEL WALL
MOUNTED
HAND SINK
1/ 2"
1/ 2"
SINK
1/ 2"
1/ 2"
3/4"
1/2" 1/2"
EYE
WASH
STATION
1/2"
1/2"1/2"
MODULE
PERIMETER
MODULE A
MODULE B
MODULE C
MODULE D
MODULE E
MODULE F
MODULE G
MODULE
MATELINE
MODULE H
MODULE I
MODULE J
MODULE K
MODULE L
MODULE M
MODULE N
MODULE O
MODULE P
MODULE H
SINK
SINK
LAV
LAV
LAV
WC
LAV
WC
LAV
LAV
LAV
LAV
LAV
LAV
LAV
MOP
SINK
LAV
LAV
1/2"
1/ 2"1/
2"
3/4"
1/ 2"1/
2"
VALVE
T&P
30 GAL.
W/H
1" A-112
1"
1"
1"
1"
1" 1/2"
SINK
1/2"
1/ 2"1/
2" 1/2"
1/2"
1/2"
3/4"
3/4"
1/2" 1/2"
LAV
LAV 3/4"
3/4"
1/2" 1/2"
LAV
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
WF
1/2"
1"
1"
1"
1" 3/4"
3/4"
3/4"
1"
1"
1/2"
1/ 2"1/
2"
1/2"
1/ 2"1/
2"
1/ 2"1/
2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1"
1 1/4"
1 1/4"
1" 3/4"
1/2"
1/2"
1/ 2"1/ 2"
1/ 2"
WC
1/ 2"1/
2"
1 1/4"
1 1/4"
1 1/4"
1 1/4"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"1/ 2"
1/ 2"
1/ 2"
1/ 2"1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
F.D.
w/T.P.
F.D.
w/T.P.
F.D.
w/T.P.
F.D.
w/T.P.
1"
1"
1"
1"
1"
3/4"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1/2"
3/4"
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
HOT RETURN
P D
F cr ea te d w ith p df Fa ct or y tri al v er si on w w w
.p df fa ct or y.
co m http://www.pdffactory.com tim.kitchens Snapshot