49_24__TPF1.0_Full_Building_Elevations.pdf

PDF 478 KB Posted

Attached to
Tyndall AFB Temporary Modular Medical Facility Federal contract opportunity
Solicitation number
W9127S19Q6039
Issued by
Department of the Army Corps of Engineers Engineering District Little Rock

About this file

Part of Attachment I - As-Builts, 49-TPF Combined

View the file

Other files for this federal contract opportunity

Other files attached to Tyndall AFB Temporary Modular Medical Facility, newest first.
File Type Posted
49_22__TLV2.0_Combined_Clinic_TPF_Low_Voltage_Systems_Notes_&_Details.pdf PDF
1-V1.07_SURVEY_PLAN.pdf PDF
1-V1.02_SURVEY_PLAN.pdf PDF
49_24__TPF2.0_Full_Building_Plan.pdf PDF
49_23__TCP1.4-PII_Combined_Clinic_TPF_RCP-PHASE_II.PDF PDF
1-V1.06_SURVEY_PLAN.pdf PDF
49_24__TPF6.0_Overall_Plumbing_Plan_-_Supply.pdf PDF
49_21__TFP3.1_Combined_Clinic_TPF_Fire_Suppression_Plan_Phase_1.pdf PDF
49_23__TCP1.1_Combined_Clinic_TPF_RCP.pdf PDF
49_25__TPFV1.0_COVER_SHEET_STAMPED.pdf PDF
49_25__TPFV8.0_CANOPY_ASSEMBLY_AND_FOOTING_DETAILS_STAMPED.pdf PDF
55_TQ3.11D_-_FFE_PLAN_-_TPF_PHASE_1,_AREA_D.pdf PDF
55_TQ4.11_-_FFE_PLAN_-_TPF_PHASE_2.pdf PDF
49_21__TFP1.0_Combined_Clinic_TPF_Life_Safety_Narrative.pdf PDF
1-V1.04_SURVEY_PLAN.pdf PDF
49_25__TPFV4.0_STANDARD_RAMP_AND_STAIR_DETAILS_STAMPED.pdf PDF
55_TQ3.11C_-_FFE_PLAN_-_TPF_PHASE_1,_AREA_C.pdf PDF
55_TQ3.11_-_FFE_PLAN_-_TPF_PHASE_1.pdf PDF
55_TQ4.11C_-_FFE_PLAN_-_TPF_PHASE_2,_AREA_C.pdf PDF
49_24__TPF3.0_Full_Luminary_Plan.pdf PDF
36_12_TSM1.0_Mechanical_HVAC_Plan.pdf PDF
29_03_TNP4.0_Plumbing_Plan_-_DWV.pdf PDF
29_01_TNC1.0_Cover_Sheet-Notes.pdf PDF
29_03_TNP1.0_Plumbing_Schematics.pdf PDF
43_19_TCCX2.0_Roof_Drain_Details.pdf PDF
43_19_TCCX1.0_Building_Cross_Section.pdf PDF
29_07_TNFD1.0_Foundation_Plan_and_Details.pdf PDF
36_11_TSE1.1_Electrical_Panel_Schedules.pdf PDF
36_10_TSP3.0_Plumbing_Plan_-_Supply_Phase_1.pdf PDF
05_1-CU1.01_UTILITY_PLAN_-_PHASE_1.pdf PDF
43_20_TCCFD1.0_Foundation_Plan_and_Details.pdf PDF
36_09_TSA4.0-PII_Egress_Plan.pdf PDF
07_ES1-01_-_ELECTRICAL_SITE_PLAN_-_MEDICAL_CLINIC_BUILDING_1465.pdf PDF
36_11_TSE3.0-PII_Task_Lighting_Illumination_Plan_Phase_2.pdf PDF
29_06_TNX1.0_Building_Cross_Section.pdf PDF
43_16_TCCA1.0_Exterior_Elevations.pdf PDF
36_10_TSP3.0-PII_Plumbing_Plan_-_Supply_Phase_2.pdf PDF
07_E0-02_-_SYMBOL_LEGEND_AND_GENERAL_NOTES.pdf PDF
36_09_TSA2.0_Floor_Plan.pdf PDF
36_11_TSE3.0_Task_Lighting_Illumination_Plan.pdf PDF
29_02_TNA4.0_Egress_Plan.pdf PDF
36_09_TSA3.0_Reflective_Ceiling_Plan.pdf PDF
29_03_TNP2.0_Plumbing_Schematics.pdf PDF
43_16_TCCA4.0_Egress_Plan.pdf PDF
43_17_TCCE1.0_Elec_Plan.pdf PDF
29_04_TNE3.0_Task_Lighting_Illumination_Plan.pdf PDF
29_05_TNM1.0_Mechanical_HVAC_Plan.pdf PDF
Attachment_C_-_AFMSA_Design_Guidance.pdf PDF
Attachment_B_-_Utility_Plans.pdf PDF
W9127S19Q6039_Tyndall_TMMF_Combined_Synopsis_Solicitation.pdf PDF
Show all 50

Tyndall AFB Temporary Modular Medical Facility has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F U

L L B

U

IL

D

IN

G E

L E

V A

T

IO

N S

TPF-

1.0

GENERAL NOTES:

1. RE. DESIGN ANALYSIS FOR EXTERIOR AND INTERIOR FINISH

SCHEDULE AND CUT SHEETS.

2. RE FLOOR PLANS FOR WINDOW TYPES.

3. RE. TCC-X1.0 FOR GUTTER AND ROOF DRAINAGE DETAILS.

A

54321

B

C

D

E

B A

S E

C

IV

IL

E

N G

IN

E

E R

/D E

P U

T Y

C H

IE

F

E N

G

IN

E E

R

IN

G F

L

IG

H T

C

E P

C H

IE

F

C O

N T

R A

C T

S S

E C

T

IO

N

C E

P M

R E

C O

M M

E N

D E

D

R E

C O

M M

E N

D E

D

A P

P R

O V

E D

R E

V D

A T

E E

N G

IN

E

E R

\D E

S

IG

N E

R

D R

A W

N B

Y

S C

A L E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

C O

N T

R A

C T

N U

M B

E R

D E

S

IG

N T

E A

M C

E P

M

U S

IN

G

A G

E N

C Y

C H

E C

K E

D B

Y

H O

E F

E R

W Y

S O

C K

I

A R

C H

IT

E

C T

S

/3

/2

JE DUNN + HWA

CLEARWATER, FL 33756

CONSULTING ENGINEER

1765 CARNEGIE AVENUE

Ph: (727) 505-9941

JAMES E. BRADLEY, P.E.

J E B

0' 4' 8' 16' 32'

1/8" = 1'-0"

0' 2' 4' 8' 16'

1/4" = 1'-0"

0' 1' 2'

3/4" = 1'-0"

4'0' 1'

1 1/2" = 1'-0"

2' 2'1'6"6"3"0' 6"

3" = 1'-0"

1'3"

NOT FOR CONSTRUCTION

2500 INDUSTRIAL STREET LEESBURG, FL 34748 (352) 728-2930

TPF TYNDALL -

CONNECTING CORRIDOR

T Y

N D

A L

L A

F B

C O

N N

E C

T

IN

G C

O R

R

ID

O R

M

A G

N O

L

IA

C

IR

C L

E T

Y N

D A

L L

A F

B

F L

A S

I N

D

IC

A T

E D

J .L

.B

W -1

-R

-6

W -1

-D

-6

J A

M E

S E

B

R A

D L E

Y P

.E

J E

D U

N N

S U

B M

IT

T

A L

C

O R

R E

C T

E D

F

IN

A L

J .E

.B

S y m b o l

D es cr ip ti o n

T ra ck in g N o

A ct io n

D at e

TPF TYNDALL - NORTH

PUBLIC HEALTH BLDG

TPF TYNDALL - SOUTH

AMBULANCE SERVICES BLDG

SCALE: 1/4"=1'-0"

SIDEWALL ELEVATION - TYNDALL NORTH

SCALE: 1/4"=1'-0"

ENDWALL ELEVATION - TYNDALL NORTH

SCALE: 1/4"=1'-0"

SIDEWALL ELEVATION - TYNDALL NORTH

20.50

22.50

19.10

22.50

19.10

22.50

20.50

22.50

19.60

22.50

ABCDGiK EFHJLNoP M

P

A

EPDM RUBBER

ROOFING

5/16 NICHIHA PANELS OVER

APPROVED MOISTURE

5/16 NICHIHA TRIM

5/16 NICHIHA PANELS OVER

APPROVED MOISTURE

ALUM

GUTTER,

TYP.

ALUM

DOWNSPOUT,

TYP.

ALUM GUTTER,

TYP.

ALUM

DOWNSPOUT,

TYP.

30.50

34.00

30.50

34.00

30.50

34.00

11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8"

186'-8"

60'-0"

ALUM

DOWNSPOUT,

TYP.

ALUM GUTTER

ALUM GUTTER

RE. TCC 1.0 FOR CENTER PORTION

AND THE ENTIRE EAST ELEVATION

RE TPF 1.0 FOR CONTINUATION OF

ELEVATION.

SCALE: 3/16"=1'-0"

ENDWALL ELEVATION - TYNDALL SOUTH

SCALE: 3/16"=1'-0"

SIDEWALL ELEVATION - TYNDALL SOUTH

SCALE: 3/16"=1'-0"

SIDEWALL ELEVATION - TYNDALL SOUTH

19.50

22.50

19.50

22.50

19.60

22.50

19.60

22.50

EPDM RUBBER

ROOFING

5/16 NICHIHA PANELS OVER

APPROVED MOISTURE

5/16 NICHIHA TRIM

5/16 NICHIHA PANELS OVER

APPROVED MOISTURE

/2

A B C D G i KE F H J L N o PM

P

A

ALUM

GUTTER,

TYP.

ALUM

DOWNSPOUT,

TYP.

19.40

22.50

19.80

22.50

SITE INSTALLED CANOPY

SITE INSTALLED CANOPY

SITE INSTALLED CANOPY

30.50

34.00

30.50

34.00

30.50

34.00

30.50

34.00

6'-0"

6'-0"

11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8"

186'-8"

ALUM GUTTER

ALUM

GUTTER,

TYP.

60'-0"

RE. TCC 1.0 FOR CENTER PORTION

AND THE ENTIRE EAST ELEVATION

RE TPF 1.0 FOR CONTINUATION OF

ELEVATION.

ALUM GUTTER,

TYP.

60'-0"

RE. TCC 1.0 FOR CENTER PORTION

AND THE ENTIRE EAST ELEVATION

RE TPF 1.0 FOR CONTINUATION OF

ELEVATION.

60'-0"

RE. TCC 1.0 FOR CENTER PORTION

AND THE ENTIRE EAST ELEVATION

RE TPF 1.0 FOR CONTINUATION OF

ELEVATION.

SCALE: 1/4"=1'-0"

ENDWALL ELEVATION - TYNDALL CORRIDOR

A

EPDM RUBBER

ROOFING

5/16 NICHIHA PANELS OVER

APPROVED MOISTURE

SITE INSTALLED CANOPY

5/16 NICHIHA PANELS OVER

APPROVED MOISTURE

SCALE: 1/4"=1'-0"

RIGHT ENDWALL ELEVATION - TYNDALL CORRIDOR

B

SITE INSTALLED CANOPY

10'-0"

VALID

January 27, 2017

File details come from the government source that posted it.