49_24__TPF1.0_Full_Building_Elevations.pdf
PDF 478 KB Posted
- Attached to
- Tyndall AFB Temporary Modular Medical Facility Federal contract opportunity
- Solicitation number
- W9127S19Q6039
About this file
Part of Attachment I - As-Builts, 49-TPF Combined
View the file
Other files for this federal contract opportunity
Show all 50
Tyndall AFB Temporary Modular Medical Facility has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F U
L L B
U
IL
D
IN
G E
L E
V A
T
IO
N S
TPF-
1.0
GENERAL NOTES:
1. RE. DESIGN ANALYSIS FOR EXTERIOR AND INTERIOR FINISH
SCHEDULE AND CUT SHEETS.
2. RE FLOOR PLANS FOR WINDOW TYPES.
3. RE. TCC-X1.0 FOR GUTTER AND ROOF DRAINAGE DETAILS.
A
54321
B
C
D
E
B A
S E
C
IV
IL
E
N G
IN
E
E R
/D E
P U
T Y
C H
IE
F
E N
G
IN
E E
R
IN
G F
L
IG
H T
C
E P
C H
IE
F
C O
N T
R A
C T
S S
E C
T
IO
N
C E
P M
R E
C O
M M
E N
D E
D
R E
C O
M M
E N
D E
D
A P
P R
O V
E D
R E
V D
A T
E E
N G
IN
E
E R
\D E
S
IG
N E
R
D R
A W
N B
Y
S C
A L E
S O
L
IC
IT
A
T
IO
N N
U M
B E
R
C O
N T
R A
C T
N U
M B
E R
D E
S
IG
N T
E A
M C
E P
M
U S
IN
G
A G
E N
C Y
C H
E C
K E
D B
Y
H O
E F
E R
W Y
S O
C K
I
A R
C H
IT
E
C T
S
/3
/2
JE DUNN + HWA
CLEARWATER, FL 33756
CONSULTING ENGINEER
1765 CARNEGIE AVENUE
Ph: (727) 505-9941
JAMES E. BRADLEY, P.E.
J E B
0' 4' 8' 16' 32'
1/8" = 1'-0"
0' 2' 4' 8' 16'
1/4" = 1'-0"
0' 1' 2'
3/4" = 1'-0"
4'0' 1'
1 1/2" = 1'-0"
2' 2'1'6"6"3"0' 6"
3" = 1'-0"
1'3"
NOT FOR CONSTRUCTION
2500 INDUSTRIAL STREET LEESBURG, FL 34748 (352) 728-2930
TPF TYNDALL -
CONNECTING CORRIDOR
T Y
N D
A L
L A
F B
C O
N N
E C
T
IN
G C
O R
R
ID
O R
M
A G
N O
L
IA
C
IR
C L
E T
Y N
D A
L L
A F
B
F L
A S
I N
D
IC
A T
E D
J .L
.B
W -1
-R
-6
W -1
-D
-6
J A
M E
S E
B
R A
D L E
Y P
.E
J E
D U
N N
S U
B M
IT
T
A L
C
O R
R E
C T
E D
F
IN
A L
J .E
.B
S y m b o l
D es cr ip ti o n
T ra ck in g N o
A ct io n
D at e
TPF TYNDALL - NORTH
PUBLIC HEALTH BLDG
TPF TYNDALL - SOUTH
AMBULANCE SERVICES BLDG
SCALE: 1/4"=1'-0"
SIDEWALL ELEVATION - TYNDALL NORTH
SCALE: 1/4"=1'-0"
ENDWALL ELEVATION - TYNDALL NORTH
SCALE: 1/4"=1'-0"
SIDEWALL ELEVATION - TYNDALL NORTH
20.50
22.50
19.10
22.50
19.10
22.50
20.50
22.50
19.60
22.50
ABCDGiK EFHJLNoP M
P
A
EPDM RUBBER
ROOFING
5/16 NICHIHA PANELS OVER
APPROVED MOISTURE
5/16 NICHIHA TRIM
5/16 NICHIHA PANELS OVER
APPROVED MOISTURE
ALUM
GUTTER,
TYP.
ALUM
DOWNSPOUT,
TYP.
ALUM GUTTER,
TYP.
ALUM
DOWNSPOUT,
TYP.
30.50
34.00
30.50
34.00
30.50
34.00
11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8"
186'-8"
60'-0"
ALUM
DOWNSPOUT,
TYP.
ALUM GUTTER
ALUM GUTTER
RE. TCC 1.0 FOR CENTER PORTION
AND THE ENTIRE EAST ELEVATION
RE TPF 1.0 FOR CONTINUATION OF
ELEVATION.
SCALE: 3/16"=1'-0"
ENDWALL ELEVATION - TYNDALL SOUTH
SCALE: 3/16"=1'-0"
SIDEWALL ELEVATION - TYNDALL SOUTH
SCALE: 3/16"=1'-0"
SIDEWALL ELEVATION - TYNDALL SOUTH
19.50
22.50
19.50
22.50
19.60
22.50
19.60
22.50
EPDM RUBBER
ROOFING
5/16 NICHIHA PANELS OVER
APPROVED MOISTURE
5/16 NICHIHA TRIM
5/16 NICHIHA PANELS OVER
APPROVED MOISTURE
/2
A B C D G i KE F H J L N o PM
P
A
ALUM
GUTTER,
TYP.
ALUM
DOWNSPOUT,
TYP.
19.40
22.50
19.80
22.50
SITE INSTALLED CANOPY
SITE INSTALLED CANOPY
SITE INSTALLED CANOPY
30.50
34.00
30.50
34.00
30.50
34.00
30.50
34.00
6'-0"
6'-0"
11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8"
186'-8"
ALUM GUTTER
ALUM
GUTTER,
TYP.
60'-0"
RE. TCC 1.0 FOR CENTER PORTION
AND THE ENTIRE EAST ELEVATION
RE TPF 1.0 FOR CONTINUATION OF
ELEVATION.
ALUM GUTTER,
TYP.
60'-0"
RE. TCC 1.0 FOR CENTER PORTION
AND THE ENTIRE EAST ELEVATION
RE TPF 1.0 FOR CONTINUATION OF
ELEVATION.
60'-0"
RE. TCC 1.0 FOR CENTER PORTION
AND THE ENTIRE EAST ELEVATION
RE TPF 1.0 FOR CONTINUATION OF
ELEVATION.
SCALE: 1/4"=1'-0"
ENDWALL ELEVATION - TYNDALL CORRIDOR
A
EPDM RUBBER
ROOFING
5/16 NICHIHA PANELS OVER
APPROVED MOISTURE
SITE INSTALLED CANOPY
5/16 NICHIHA PANELS OVER
APPROVED MOISTURE
SCALE: 1/4"=1'-0"
RIGHT ENDWALL ELEVATION - TYNDALL CORRIDOR
B
SITE INSTALLED CANOPY
10'-0"
VALID
January 27, 2017
File details come from the government source that posted it.