RFI 3 Q-21 - A1.0.pdf
PDF 1 MB Posted
- Solicitation number
- W9127Q-20-B-0024
About this file
This solicitation is for construction services to renovate Building 181 Small Air Terminal at Mississippi Air National Guard 172nd Airlift Wing in Flowood, MS. Services include complete interior and exterior renovation with replacement of all exterior doors and windows, interior finishes, HVAC, electrical, fire protection, and plumbing systems. The work is a 100% small business set-aside with a NAICS code of 236220 and size standard of $39.5 million average annual revenue. The estimated value ranges from $1-5 million. Interested offerors must attend the pre-bid conference on August 25, 2020 and submit quotes by the bid opening date of September 21, 2020. The solicitation and plans are available through the SAM website.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
XX
COVERED
SCREENED
MECHANICAL
AREA 443 SF
XXX
XXX
RAMP
STAIR 2
S2
HVAC ABOVE
SEE STRUC. & MECH.
PALLET BUILD-UP
& STORAGE AREA
AERIAL DELIVERY PREP
& STORAGE AREA
106A SECURE STORAGE
106B
SECURE STORAGE
106C
SECURE STORAGE
106D
JOINT INSPECTION TEAM
(TRAINING & TESTING)
COMFORT ITEM
STORAGE
ENTRY VESTIBULE
100A
LOBBY
100B
PASSAGE
PASSAGE
FLEET NON-EXPENDABLES
/EXPENDABLES STORAGE
WORK RM/COPY
BREAK AREA
AIRCRAFT SERVICES /
CONFERENCE ROOM
103 PPE TRAINING
BAG STORAGE
DATA
JANITOR
MECHANICAL /
ELETRICAL
A3.0
A4.0
STAIR 1
S1
WOMENS
MENS
PASSENGER
RECEPTION
CHIEFS
1ST SRGT
ADMIN. COMMAND 1
A
A
MA
TC
HL
IN
E
MA
TC
HL
IN
E
A4.0
A3.0
A3.1
A4.0
1HR
1H R
REF.MW
DS OD LAMB'S
TONGUE
BENCH
SLOPED WALK (1:20 MAX. SLOPE)- SEE CIVIL
FD FD FD
FD FD
FD
A B
C
9'- 3"
9'- 3"
230'-0"
100'-8" 9'-4"
2'-
61 4"
'-0
'-8
3 4"
'-3 1 2"
230'-0" 65'-33
8"VIF 26'-85
8"VIF 18'-0"± 8'-2"
5'- 0"
FACE OF
EXIST. CMU
1'-6"
291.94'
292.5' 290.5'
REF.OIM
JI EQUIP STORAGE
JI EQUIPMENT
STORAGE
1H R
1H R
1HR 1HR 1HR 1HR 1HR
1HR
1HR
104105106107
108B
H
BDD
EXIST.
CONC.
EXIST.
ROLLERS
113A
A5.0
A5.0
EX
EX
EX
EX
JOINT INSPECTION
A6.0
A5.2
1/A11.0 2/A11.0
TV
M8.0.48 S4.0.49
S6.0.51 S4.0.49
F1.0.0
S4.0.0
S4.0.49 S9.0.49
S4.0.49 S4.0.49
M8.0.48 M8.0.48
S6.0.0 F1.0.0
M6.0.45
COMFORT PALLETS - N.I.C.
S4.0.49
S4.0.0
S4.0.49M6.0.45 F1.0.0
F1.0.0S4.0.49
S4.0.49
F1.0.0
S11.0.51
F1.0.0F1.0.0
M6.0.45
S6.1.51
S4.0.49
F1.0.0
S11.0.51F1.0.0
F1.0.0
F1.0.0
S4.0.49
S4.0.49
1HR1HR1HR1HR1HR1HR1HR
ELEVATOR
EL 1
G G
F
291.94'
291.94'
291.94'
291.94'
289.86'
EJBEJ BEJ
289.95'
A6.0
F1.0.0
F1.0.0
2 6
2 6
A6.1 1A
A6.1 2A
CONCRETE BENCH - SEE AS1.0
1'-2" 8'-0"
35'-71 2" 6" 12'-91
8" 35 8" 11'-63
8" 35 8" 11'-113
4"
A6.0 1A
FEC
FEC
A5.1
A5.1
L1
L2
FENCING
TO DECK -
SEE SPEC
PTD
EXISTING
LADDER
108A
FENCING
TO DECK -
SEE SPEC
EX EX EX EX EX EX
PTD STL
COLUMN
PTD STL
COLUMN
PTD STL
COLUMN
PTD STL
COLUMN
F1.0.0
A5.0
A5.0
FLOOR PLAN LEGEND
NEW EXTERIOR WALL-SEE WALL SECTIONS
EXISTING WALL TO REMAIN -
SHOWN LIGHT GRAY W/ NO HATCH
NEW CMU PARTITION - SEE WALL TYPES
NEW STUD PARTITION - SEE WALL TYPES
NEW ALUMINUM STOREFRONT - SEE SPEC
1 HR FIRE RATING - SEE WALL TYPES1HR 1HR
NEW CONCRETE SLAB
WIRE MESH PARTITION-SEE WALL TYPESX X X
F1.0.0 WALL TYPES - SEE A0.0
ELECTRIC DRINKING FOUNTAIN - SEE MECH
FEC FIRE EXTINGUISHER W/ CABINET
EDF
FD
NEW DOOR W/ TAG - SEE DOOR SCHEDULE
NEW FLOOR DRAIN - SEE PLUMBING
NEW PLUMBING FIXTURES - SEE PLUMBING
1/8"=1'-0"
FIRST FLOOR PLAN - NORTH1
0 2' 4' 8' 16' 30'
N
WAGGONER
Jackson, MS Hernando, MS Gulfport, MS Ruston, LA New Orleans, LA www.waggonereng.com 1-800-661-3733
Inspire. Engage. Deliver.
DRAWING REVISIONS
NO. REMARKS DATE
SEAL
PR
OJ
EC
T#
LR
XQ
MS
A
IR
N
AT
IO
NA
L G
UA
RD
2N
D
AI
RL
IF
T W
IN
G
RE
NO
VA
TE
S
MA
LL
A
IR
TE
RM
IN
AL
B
APRIL 2020
APRIL 2020
APRIL 2020
DRAWN BY:
DESIGNED BY:
CHECKED BY:
SCALE:
DATE:
PROJECT: LRXQ172401
DRAWING TITLE
SHEET NUMBER
1/8"=1'-0"ZRH
ZRH/MDP
AMD
FIRST FLOOR PLAN-
A1.0
NORTH
AutoCAD SHX Text
MODELNUMBER
AutoCAD SHX Text
TRADENAME
AutoCAD SHX Text
PRODUCT
AutoCAD SHX Text
MATERIAL
Scott Thaggard Polygon
Scott Thaggard Line
Scott Thaggard Typewritten Text There's no slab demo shown at this location on D1.0
Scott Thaggard Rectangle
Scott Thaggard Line
Scott Thaggard Typewritten Text Should new concrete be shown here?
Concrete removed per D1.0
Scott Thaggard Typewritten Text There's no slab demo shown at this location on D1.0
Scott Thaggard Line
Scott Thaggard Typewritten Text There's under slab piping at these locations
Scott Thaggard Line
Scott Thaggard Polygon
Scott Thaggard Polygon
Scott Thaggard Typewritten Text Under slab piping crossing at these locations.
Scott Thaggard Line
Scott Thaggard Line
Scott Thaggard Polygon
Scott Thaggard Polygon
File details come from the government source that posted it. Updated .