AMEND 1 DRAWING - B181 S102 Rev 1-09112020.pdf

PDF 123 KB Posted

Attached to
Renovation Building 181 Small Air Terminal, #LRXQ172401
Solicitation number
W9127Q-20-B-0024
Issued by

About this file

This solicitation is for renovation services for Building 181 Small Air Terminal at Mississippi Air National Guard 172nd Airlift Wing in Flowood, Mississippi. The services include complete interior and exterior renovation such as replacement of all exterior doors and windows, as well as all interior finishes, HVAC, electrical, fire protection, site work, DDC controls and plumbing systems. The work is classified as NAICS 236220 with a size standard of $39.5 million. The solicitation is set aside entirely for small businesses. The government estimates the contract value will be between $1 million to $5 million. A pre-bid conference will be held on August 25, 2020, and bids are due by September 21, 2020. Funding is not presently available but is expected to be in place by September 30, 2020. Interested parties must register in SAM and access solicitation documents through the beta.sam website.

View the file

Other files

File Type Posted
OF 1419 for B181 Small Air Terminal 09222020.pdf PDF
AMEND 3 SECTION 26 22 13 - B181 Transformers 09172020.pdf PDF
AMENDMENT 3 - W9127Q-20-B-0024 B181 Small Air Terminal LRXQ172401.pdf PDF
RFI 5 QA - W9127Q-20-B-0024 Bldg 181 Small Air Terminal.pdf PDF
AMEND 2 DRAWING - B181 A1.0 REPLACE 09162020 .pdf PDF
AMEND 2 DRAWING - B181 P1.0 REPLACE 09162020 .pdf PDF
AMENDMENT 2 - W9127Q-20-B-0024 B181 Small Air Terminal LRXQ172401.pdf PDF
RFI 4 QA - W9127Q-20-B-0024 Bldg 181 Small Air Terminal.pdf PDF
AMEND 2 DRAWING - B181 D1.0 REPLACE 09162020 .pdf PDF
AMENDMENT 1 - W9127Q-20-B-0024 B181 Small Air Terminal LRXQ172401.pdf PDF
RFI 3 QA - W9127Q-20-B-0024 Bldg 181 Small Air Terminal.pdf PDF
RFI 3 Q-21 - D1.0.pdf PDF
AMEND 1 DRAWING - B181 S101 Rev 1-09112020.pdf PDF
RFI 3 Q-21 - P1.0.pdf PDF
AMEND 1 DRAWING - B181 E1.1 Rev 1-09142020.pdf PDF
RFI 3 Q-21 - A1.0.pdf PDF
RFI 2 QA - W9127Q-20-B-002 Bldg 181 Small Air Terminal.pdf PDF
RFI 2 QA - Fire Sprinkler Flow Test-B181 03-14-19.pdf PDF
RFI 2 QA - B181 Roof Warranty.pdf PDF
RFI 1 QA - W9127Q-20-B-0024 Bldg 181 Small Air Terminal .pdf PDF
SITE VISIT AGENDA-MINUTES - B181.pdf PDF
ROSTER-Site Visit 08-25-2020.pdf PDF
W9127Q-20-B-0024 Solicitation-Bldg 181 Small Air Terminal LRXQ172401.pdf PDF
PreSolicitation Notice - W9127Q-20-B-0024 B181 Small Arms Range REV.pdf PDF
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

B

C

D

F

1 2

3 5 6

8 9

I

11' - 1 1/2" 8' - 10 1/2" 11' - 1 1/2" 8' - 10 1/2" 11' - 1 1/2" 8' - 10 1/2" 3' - 0"

2'

1/ 2"

4'

1/

2" M

E T

A L

D E

C K

1/

2" M

E T

A L

D E

C K

EXISTING BUILDING

EXISTING BUILDING

W

X3

W18X35

W16X26

W

X3

W

X3

W

X3

W16X26

W

X3

W

X3

W10x12 @

2' O.C., MAX.

MOMENT CONNECTION,

TYP., SEE S301

FLOOR SYSTEM: 3" CONC. SLAB W/ 6x6 W2.9xW2.9 WIRE MESH ON 9/16" GALV.

METAL DECK

9'

9'

1*

A*

2* 3* 4* 5* 6* 7*

B*

C*

D*

E*

.1* 3.1*.2*

F*

G*

8.2* 9.1*

EXISTING 20H6 EXISTING 12H3

EXISTING 12H3

8H3

EXISTING

16H4

EXISTING

W10X12 (EXISTING) W10X12 (EXISTING) W10X12 (EXISTING) W10X12 (EXISTING) W10X12 (EXISTING) W10X12 (EXISTING)

W

X1

(E

XI

ST

IN

G

W

X1

(E

XI

ST

IN

G

W

X1

(E

XI

ST

IN

G

W

X1

(E

XI

ST

IN

G )E

X

IS

T

IN

G

6H

EXISTING 16H4

8H3

EXISTING

8H3

EXISTING

12H3

EXISTINGEXISTING 8H3

EXISTING 8H3

EXISTING 14H3

EXISTING 14H3

EXISTING 16H

E X

IS

T

IN

G

4H

E

X

IS

T

IN

G

H

E X

IS

T

IN

G

2H

E X

IS

T

IN

G

2H

NEW LINTEL,

SEE S301

W16X26

NEW LINTEL,

SEE S301

W

X2

NEW 4" DIA. XS

PIPE, TYPICAL

NEW LINTEL,

SEE S301

NEW LINTEL,

SEE S301

PROVIDE CHANNEL LINTEL

FROM S301 (3) PLACES

NEW LINTEL,

SEE S301

CONTRACTOR SHALL VERIFY ROOF

FRAMING AS SHOWN. NOTIFY THE

ENGINEER IMMEDIATELY IF ANY

DISCREPANCIES ARE FOUND

8' - 2"

G

E

H

S302

S301

S301

3'

4"

W14X22

S203

TYP.

HSS7x4x3/8

TYP.

HSS4x2x1/4

TYP.

2'

1/ 2"

4'

8' - 10 1/2"

S203

SCREEN WALL

BELOW

S302

L2x2x1/4 "X" BRACE

BETWEEN VERT. ANGLES

EA. SIDE

MECH. UNIT,

SEE MECH.

HVAC FRAME HANGING

FROM JOIST, SEE DETAIL

PER DETAIL S301

REINF. BAR JOIST

L2x2x1/4 "X" BRACE

BETWEEN VERT. ANGLES

EA. SIDE

MECH. UNIT,

SEE MECH.

HVAC FRAME HANGING

FROM JOIST, SEE DETAIL

SEE DETAIL S301

REINF. BAR JOIST

C12 LINTEL, SEE S301

CONNECT TO PIPE COL.

NEW 4" DIA. XS

PIPE, TYPICAL

LINTEL, SEE

DETAIL

LINTEL FOR NEW

LOUVER

WELD C12'S

TOGETHER

NEW LINTEL,

SEE S301

W

X1

NEW 4" DIA. XS

PIPE, TYPICAL

S303

TYP.

HSS7x4x3/8

TYP.

HSS4x2x1/4

TYP.

KE

NN

ETH SIMMONS MCGRAT H

STATE OF M ISS ISS IP

PI

ENGINEERLI

CE

NSED PROFESSIONA

L

17092

P.O. BOX 4328 JACKSON, MS 39216

(601) 982-7766

Spencer-Engineers, Inc.

Consultants

WAGGONER

Jackson, MS Hernando, MS Gulfport, MS Ruston, LA New Orleans, LA www.waggonereng.com 1-800-661-3733

Inspire. Engage. Deliver.

DRAWING REVISIONS

DATE:DESIGNED BY:

LRXQ 172401PROJECT:CHECKED BY:

DRAWING TITLE:

SHEET NUMBER:

SEAL:

SCALE:DRAWN BY:

P R

O

JE

C T

LR

X Q

M S

A

IR

N A

T

IO

N A

L G

U A

R D

2N

D A

IR

LI

F T

W

IN

G

R E

N O

V A

T E

S M

A

LL

A

IR

T E

R M

IN

A

L B

SE# 18042

5−7−2020

1/8" = 1'-0"

SECOND FLOOR

AND CANOPY

FRAMING PLAN

KSM

Designer

S102

April 2020

Checker

1/8" = 1'-0"

SECOND FLOOR, LOW ROOF, AND CANOPY FRAMING PLAN

REINFORCE ALL BAR JOISTS

THAT SUPPORT THE NEW

MECH. UNIT, SEE S301 FOR

DETAIL

REINFORCE ALL BAR JOISTS

THAT SUPPORT THE NEW

MECH. UNIT, SEE S301 FOR

DETAIL

NOTES:

1. VERIFY ALL DIMENSIONS WITH ARCHITECT.

2. PROVIDE C12 LINTEL PER S301 AT ALL OPENINGS IN LOAD

BEARING WALLS. NOT ALL LOCATIONS ARE SHOWN. IT IS

THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL

LOCATIONS.

NO. REMARKS DATE

1 Revision 1 9-11-2020