AMENDMENT 2 - W9127Q-20-B-0024 B181 Small Air Terminal LRXQ172401.pdf

PDF 87 KB Posted

Attached to
Renovation Building 181 Small Air Terminal, #LRXQ172401
Solicitation number
W9127Q-20-B-0024
Issued by

About this file

This document provides details for Amendment 2 to Solicitation Number W9127Q-20-B-0024 for renovation services at Building 181 Small Air Terminal. The amendment revises specifications for gutters and downspouts, deletes certain lighting and control specifications, adds generator power to building corridors, notes demolition requirements for floor raceways and boxes, and replaces site and floor plans. Services required include interior and exterior renovation with replacement of doors, windows, finishes, HVAC, electrical, fire protection, plumbing and DDC control systems. The solicitation is a 100% small business set-aside for qualified offerors between $1-5 million. The pre-proposal conference was on August 25, 2020 and proposals are due by September 21, 2020. The agency is the Department of the Army Mississippi Army National Guard for the 172nd Airlift Wing located in Flowood, Mississippi.

View the file

Other files

File Type Posted
OF 1419 for B181 Small Air Terminal 09222020.pdf PDF
AMEND 3 SECTION 26 22 13 - B181 Transformers 09172020.pdf PDF
AMENDMENT 3 - W9127Q-20-B-0024 B181 Small Air Terminal LRXQ172401.pdf PDF
RFI 5 QA - W9127Q-20-B-0024 Bldg 181 Small Air Terminal.pdf PDF
AMEND 2 DRAWING - B181 A1.0 REPLACE 09162020 .pdf PDF
AMEND 2 DRAWING - B181 P1.0 REPLACE 09162020 .pdf PDF
RFI 4 QA - W9127Q-20-B-0024 Bldg 181 Small Air Terminal.pdf PDF
AMEND 2 DRAWING - B181 D1.0 REPLACE 09162020 .pdf PDF
AMENDMENT 1 - W9127Q-20-B-0024 B181 Small Air Terminal LRXQ172401.pdf PDF
RFI 3 QA - W9127Q-20-B-0024 Bldg 181 Small Air Terminal.pdf PDF
RFI 3 Q-21 - D1.0.pdf PDF
AMEND 1 DRAWING - B181 S102 Rev 1-09112020.pdf PDF
AMEND 1 DRAWING - B181 S101 Rev 1-09112020.pdf PDF
RFI 3 Q-21 - P1.0.pdf PDF
AMEND 1 DRAWING - B181 E1.1 Rev 1-09142020.pdf PDF
RFI 3 Q-21 - A1.0.pdf PDF
RFI 2 QA - W9127Q-20-B-002 Bldg 181 Small Air Terminal.pdf PDF
RFI 2 QA - Fire Sprinkler Flow Test-B181 03-14-19.pdf PDF
RFI 2 QA - B181 Roof Warranty.pdf PDF
RFI 1 QA - W9127Q-20-B-0024 Bldg 181 Small Air Terminal .pdf PDF
SITE VISIT AGENDA-MINUTES - B181.pdf PDF
ROSTER-Site Visit 08-25-2020.pdf PDF
W9127Q-20-B-0024 Solicitation-Bldg 181 Small Air Terminal LRXQ172401.pdf PDF
PreSolicitation Notice - W9127Q-20-B-0024 B181 Small Arms Range REV.pdf PDF
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

W9127Q-20-B-0024 B181 Small Air Terminal, #LRXQ172401

AMENDMENT #2

17 September 2020

8. Gutter Specifications: REPLACE/REVISE Specification Section 076200 Sheet Metal

Flashing and Trim, subsection 2.05 Gutter and Downspout Fabrication to read as follows:

A. Gutters: Gutters shall be fabricated from sheet metal at gauge given below. Finish shall match metal trim and metal panels. Fabricate to cross section indicated, complete with end pieces, outlet tubes, and other accessories as required. Furnish flat-stock gutter spacers and gutter brackets fabricated from same metal as gutters, of size recommended by SMACNA but not less than twice the gutter thickness. Fabricate expansion joints, expansion joint covers, and gutter accessories from same metal as gutters. SMACNA rectangular profile, Figure 1-2, Style A, gauge as follows:

1. 8"x 8" or larger: 22 gauge.

2. Smaller than 8" x 8": 24 gauge.

B. Downspouts: Profile as indicated.

C. Gutters and Downspouts: Size as indicated.

D. Accessories: Profiled to suit gutters and downspouts.

1. Anchorage Devices: In accordance with SMACNA (ASMM) requirements.

2. Gutter Supports: Brackets

3. Downspout Supports: Supports as indicated in the drawings.

9. REPLACE sheets D1.0, A1.0, and P1.0

10. Sheet D1.0 – demolition note #4 regarding gypsum board.

REMOVE Demolition Note #4 as there are no interior gypsum board partitions. At all locations noted with Demo Note #4, REPLACE with Demo Note #16.

11. DELETE this reference marker, sheet MA8.4. No longer in this project.

AMENDMENT #1

15 September 2020

1. While we had the Siprnet and Plan Room on the emergency panel for generator power, we needed to have the corridors on generator power as well. Circuits are revised as shown.

ADD/REPLACE - AMEND 1 DRAWING - B181 E1.1 REV-1 09142020

2. Specifications section 26 09 42 – DELETE items 2.1 (A)(1) and (2). There will be no prior approval given on lighting and controls.

W9127Q-20-B-0024 B181 Small Air Terminal, #LRXQ172401

3. Sheet E1.2 - Floor raceway keynote #5, ADD “Contractor shall demolish existing slab to install metal raceway flush with floor, Leviton “Walkerduct” or equal with all appropriate fittings and accessories.”

4. Sheet ED1.2 – NOTE/ADD Symbol with “FB” in rectangle denotes existing floor box to be demolished.

5. REPLACE Plan sheet S101 with:

AMEND 1 DRAWING - B181 S101 Rev 1-09112020 (Question #6 of RFI #3)

7. REPLACE Plan sheet S102.

AMEND 1 DRAWING - B181 S102 Rev 1-09112020 (Question #7 of RFI #3)

REMINDER:

1. Proposal Due Date – Monday, September 21, 2020 @ 10:00 AM (CST)