This solicitation seeks proposals for construction services to renovate Building 181 Small Air Terminal at Mississippi Air National Guard 172nd Airlift Wing in Flowood, Mississippi. The scope of work includes complete interior and exterior renovation with replacement of all exterior doors and windows as well as interior finishes, HVAC, electrical, fire protection, site work, and plumbing systems. The NAICS code is 236220 and the solicitation is set aside entirely for small businesses with average annual revenue under $39.5 million for the previous three years. Proposals are due by September 21, 2020 and the pre-bid conference will be held on August 25, 2020. Interested offerors must register in SAM and the solicitation documents are available through beta.sam.gov. The contract value is estimated between $1-5 million and funds are anticipated but not presently guaranteed to become available by September 30, 2020.

View the file

Other files

File Type Posted
OF 1419 for B181 Small Air Terminal 09222020.pdf PDF
AMEND 3 SECTION 26 22 13 - B181 Transformers 09172020.pdf PDF
AMENDMENT 3 - W9127Q-20-B-0024 B181 Small Air Terminal LRXQ172401.pdf PDF
RFI 5 QA - W9127Q-20-B-0024 Bldg 181 Small Air Terminal.pdf PDF
AMEND 2 DRAWING - B181 A1.0 REPLACE 09162020 .pdf PDF
AMEND 2 DRAWING - B181 P1.0 REPLACE 09162020 .pdf PDF
AMENDMENT 2 - W9127Q-20-B-0024 B181 Small Air Terminal LRXQ172401.pdf PDF
RFI 4 QA - W9127Q-20-B-0024 Bldg 181 Small Air Terminal.pdf PDF
AMEND 2 DRAWING - B181 D1.0 REPLACE 09162020 .pdf PDF
AMENDMENT 1 - W9127Q-20-B-0024 B181 Small Air Terminal LRXQ172401.pdf PDF
RFI 3 QA - W9127Q-20-B-0024 Bldg 181 Small Air Terminal.pdf PDF
RFI 3 Q-21 - D1.0.pdf PDF
AMEND 1 DRAWING - B181 S102 Rev 1-09112020.pdf PDF
RFI 3 Q-21 - P1.0.pdf PDF
AMEND 1 DRAWING - B181 E1.1 Rev 1-09142020.pdf PDF
RFI 3 Q-21 - A1.0.pdf PDF
RFI 2 QA - W9127Q-20-B-002 Bldg 181 Small Air Terminal.pdf PDF
RFI 2 QA - Fire Sprinkler Flow Test-B181 03-14-19.pdf PDF
RFI 2 QA - B181 Roof Warranty.pdf PDF
RFI 1 QA - W9127Q-20-B-0024 Bldg 181 Small Air Terminal .pdf PDF
SITE VISIT AGENDA-MINUTES - B181.pdf PDF
ROSTER-Site Visit 08-25-2020.pdf PDF
W9127Q-20-B-0024 Solicitation-Bldg 181 Small Air Terminal LRXQ172401.pdf PDF
PreSolicitation Notice - W9127Q-20-B-0024 B181 Small Arms Range REV.pdf PDF
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S201A

S201

B

C

D

F

1 2

3 5 6

8 9

I

9'

9'

8' - 2"

F5.0 F5.0

S201

HSS4x4x1/4

TYP.

11' - 1 1/2" 8' - 10 1/2" 11' - 1 1/2" 8' - 10 1/2" 11' - 1 1/2" 8' - 10 1/2"

2'

1/ 2"

4'

1*

A*

2* 3* 4* 5* 6* 7*

B*

C*

D*

E*

.1* 3.1*.2*

F*

G*

8.2* 9.1*

G

SEE S104 FOR

MORE INFORMATION

2'

1/ 2"

4'

8' - 10 1/2"

S202

S202

5' - 1 1/2"

1'

E

H

C1 C1

C1 C1

C1, SIM.C1,

SIM.

2'x2'x2'

SUMP PIT

5" CONC. SLAB W/ #3 @

12" O.C., EA. WAY

S203

S203

TYP.

TYP.

HSS4x4x3/8 TYP.

@ SCREEN WALL

5' - 0"

1' - 0"

CORE DRILL (4) 8" DIAMETER HOLES

IN THE BOTTOM OF THE PIT. FILL PIT

WITH COMPACTED SAND. PROVIDE

5" CONC. SLAB OVER SAND PER DETAIL

ON S201.

NEW 4" DIA. XS

PIPE, TYPICAL

NEW 4" DIA. XS

PIPE, TYPICAL

NEW 4" DIA. XS

PIPE, TYPICAL

PROVIDE 8" CONC. WALL TO

CLOSE OFF UNDER SLAB. REINF.

W/ #5 @ 12" O.C., EA. WAY, 1 LAYER

S401

C2

C2

C2

C2, SIM

C2, SIM

NEW 4" DIA. XS

PIPE, TYPICAL

C2

CURB, SEE ARCH. FOR

ALL LOCATIONS

S201

HSS6x6x1/4

TYP. EA. SIDE

S202

SEE 3/S202 FOR

CURB

KE

NN

ETH SIMMONS MCGRAT H

STATE OF M ISS ISS IP

PI

ENGINEERLI

CE

NSED PROFESSIONA

L

17092

P.O. BOX 4328 JACKSON, MS 39216

(601) 982-7766

Spencer-Engineers, Inc.

Consultants

WAGGONER

Jackson, MS Hernando, MS Gulfport, MS Ruston, LA New Orleans, LA www.waggonereng.com 1-800-661-3733

Inspire. Engage. Deliver.

DRAWING REVISIONS

DATE:DESIGNED BY:

LRXQ 172401PROJECT:CHECKED BY:

DRAWING TITLE:

SHEET NUMBER:

SEAL:

SCALE:DRAWN BY:

P R

O

JE

C T

LR

X Q

M S

A

IR

N A

T

IO

N A

L G

U A

R D

2N

D A

IR

LI

F T

W

IN

G

R E

N O

V A

T E

S M

A

LL

A

IR

T E

R M

IN

A

L B

SE# 18042

5−7−2020

1/8" = 1'-0"

FOUNDATION AND

FIRST FLOOR

FRAMING PLAN

KSM

Designer

S101

April 2020

Checker

1/8" = 1'-0"

FOUNDATION AND FLOOR FRAMING PLAN

HSS8x8x3/8

TYPICAL

NOTES:

1. VERIFY ALL DIMENSIONS WITH ARCHITECT.

2. AT ALL SLAB INFILL LOCATIONS, PROVIDE NEW SLAB

PER DETAIL ON S201

NO. REMARKS DATE

1 Revision 1 9-11-2020