W9127822R0008 AM03 DRAWINGS.pdf
PDF 3 MB Posted
- Solicitation number
- W9127822R0008
About this file
This solicitation is for the construction of an approximately 7,000 square foot extension to Building 73 at Eglin Air Force Base in Florida. The project involves conventional design and construction methods to accommodate ongoing mission needs and will be approximately 95% secure compartmented information facility compliant. The North American Industry Classification System code is 236220. Bidders must register in the System for Award Management and submit all bid forms electronically. Critical path methodology is required. A small business is defined as having average annual receipts less than $39.5 million for the past three years. Bid options may be included but are not guaranteed to be awarded. The request for information process will be through ProjNet and questions must be submitted by the advertisement deadline.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LAB 1
E111
LAB 2
E110
CORR.
E103
TLT
E108
LAB 4
E107
LAB 3
E106
CONF.
E105
MANTRAP
E101
ADMIN. SECURITY
E102
COMM.
E104
MECH
E109
E E
EE
E
E
E
E
E
E
E
E
G-004
UP
______1
G-005
______2
G-005
______3
G-005
TEMPORARY ENTRANCE, VESTIBULE,
RAMP, & RAILINGS
UP
UP
EXISTING FACILITY ENTRANCE
UP
EXISTING FACILITY
SECURE AREA BOUNDARY
1' -6
TO FACE OF EXISTING
1. ALL WORK FOR TEMPORARY ENTRANCE AS SHOWN ON SHEETS G-004 AND
G-005 TO BE COMPLETED BEFORE WORK CAN BEGIN THAT WILL MAKE
EXISTING ENTRY DOOR AT MANTRAP (E101) INACCESSIBLE TO FACILITY
USERS AS A FACILITY ENTRANCE.
2. AFTER FACILITY ADDITION IS COMPLETE AND USABLE, REMOVE
TEMPORARY PARTITION, DOOR, AND FRAME FROM CORRIDOR E103; AND
REMOVE TEMPORARY VESTIBULE LANDING, RAMP, RAILINGS, AND
ASSOCIATED TEMPORARY LIGHT AND RECEPTACLE.
3. PROVIDE 26 GA GALVANIZED 5V CRIMP ROOF PANELS (24" COVERAGE)
OVER SELF-ADHERED ROOF UNDERLAYMENT AT TEMPORARY
VESTIBULE/MANTRAP. ANCHOR ROOF PANELS TO P.T. PLYWOOD WITH #
9-15x1 1/2" SCREWS WITH SEALING WASHER AT 12" O.C. PROVIDE 26 GA
GALVANIZED EDGE METAL FLASHING, AND PROVIDE 26 GA GALVANIZED
METAL COUNTERFLASHING WITH CONTINUOUS SEALANT AT RAKE EDGE
AGAINST EXISTING BUILDING.
4. REFER TO THE "E" SHEETS FOR ADDITIONAL ELECTRICAL DETAILS AND
NOTES.
5. REFER TO THE "TY" SHEETS FOR ADDITIONAL SECURITY DETAILS AND
NOTES.
6. SEE 01 14 00, WORK RESTRICTIONS, FOR ADDITIONAL INFORMATION.
7. PAINT ALL EXPOSED SURFACES OF TEMPORARY VESTIBULE/MANTRAP
WALLS AND EXPOSED ROOF JOIST & UNDERSIDE OF ROOF PANELS. ONLY
PAINT P.T. PLYWOOD AND ROOF JOISTS WHEN DRY. DO NOT PAINT P.T.
RAMP & GUARDRAILS.
GENERAL NOTES
GRAPHIC LEGEND
EXISTING WALL
EXISTING ROOM NAME / NUMBER
DESIGNATION
DEAD-END CORRIDOR/TRAVEL
DISTANCE TO EXIT CREATED BY
TEMPORARY PARTITION
NEW WALL CONSTRUCTION
EXISTING FACILITY SECURE AREA LIMITS
ROOM NAME
101A
EXISTING DOOR TO REMAIN E
KEYNOTES
REMOVE EXISTING DOOR AND HARDWARE. EXISTING FRAME TO
REMAIN; MODIFY EXISTING FRAME TO ACCEPT NEW DOOR. PROVIDE
NEW HOLLOW METAL STC 53 DOOR WITH FF-L-2890C TYPE IV HIGH
SECURITY ELECTRIC LOCK WITH INTEGRATED COMBINATION SPIN
DIAL. PAINT NEW DOOR.
INSTALL RECEPTACLE 84" AFF. INSTALL AND CONNECT 2#12 AND 1#12
GROUND IN 1/2" CONDUIT TO THE EXISTING E103 CORR HALLWAY
RECEPTACLE CIRCUIT. EXISTING RECEPTACLE CIRCUIT IS LOCATED
APPROXIMATELY 25' AWAY.
(ABOVE) SURFACE MOUNT LIGHT FIXTURE TYPE 'LSE'. INSTALL AND
CONNECT 2#12 AND 1#12 GROUND IN 1/2" CONDUIT TO THE EXISTING
HALLWAY LIGHTING CIRCUIT. TAP CIRCUIT AHEAD OF THE LOCAL
SWITCH. LIGHT FIXTURE SHALL BE 24/7 ALWAYS 'ON' WITH
EMERGENCY BATTERY BACKUP.
8 GOVERNMENT WILL INSTALL TEMPORARY WHITE NOISE SPEAKER AND
CONNECTION.
9 INSTALL TEMPORARY 3/4" CONDUIT AND PULLSTRING TO CCTV
CABINET IN ROOM E102.
10 INSTALL 3/4" CONDUIT AND PULLSTRING TO EXISTING ACS PANEL IN
CORR. E103.
REMOVE EXISTING GUARDRAIL, STORE, AND REINSTALL AFTER
TEMPORARY VESTIBULE, LANDING, AND RAMP IS REMOVED.
INSTALL FIXTURE TYPE 'X'. INSTALL 2#12 AND 1#12 GROUND IN 1/2"
CONDUIT TO THE EXISTING CORRIDOR LIGHTING CIRCUIT. CONNECT
TO CIRCUIT AHEAD OF THE LOCAL SWITCH.
TEMPORARY METAL STUD AND GYPSUM BOARD PARTITION, EXTEND
FROM TOP OF EXISTING ACCESS FLOOR TO BOTTOM OF EXISTING
CEILING. PROVIDE TEMPORARY HOLLOW METAL DOOR & FRAME WITH
LEVER HANDLE PASSAGE LOCKSET.
TEMPORARY DEAD-END CORRIDOR/TRAVEL DISTANCE TO EXIT AS
SHOWN BY DASHED LINE IS NOT TO EXCEED 50'. ACTUAL DISTANCE
SHOWN IS 48'.
TEMPORARY HOLLOW METAL DOOR AND FRAME WITH 6-PIN
MECHANICAL CIPHER LOCK.
P.T. WOOD RAILINGS, SEE G-005.12
P.T. WOOD RAMP AND LANDING, SEE G-005.13
P.T. WOOD STUD WALLS AND P.T. PLYWOOD SHEATHING, SEE G-005.14
EXISTING CONCRETE STAIRS BELOW.15
S
CRK
C A
M
UP
______1
G-005
______2
G-005
______3
G-005
RAMP (1:12)
TEMPORARY
VESTIBULE/
MANTRAP
7'-10 1/2" 27'-0" +/-
TO FACE OF EXISTING
6' -1
A
SHEET
IDENTIFICATION
US Army Corps of
Engineers ® Mobile District
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S
IG
N E
D B
Y
B U
L L
O C
K T
IC
E
A S
S O
C
IA
T E
S E
C
E R
V A
N T
E S
S T
R E
E T
P E
N S
A C
O L
A F
L O
R
ID
A
2 3 4 5
B
C
D
D R
A W
N B
Y
S B
M T
B Y
P L
O T
S C
A L
E
S
IZ
E
C K
D B
Y
P L
O T
D A
T E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
P R
O J
E C
T N
U M
B E
R
F
IL
E N
A M
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
:1 x
M O
B
IL
E D
IS
T
R
IC
T M
O B
IL
E
A
L A
B A
M A
O C
T
M
E F
AMENDMENT 0003
E G
L
IN
A
IR
F O
R C
E B
A S
E F
L O
R
ID
A B
U
IL
D
IN
G
L
A B
E X
P A
N S
IO
N
G-004FTFA20DR04
T E
M P
O R
A R
Y E
N T
R A
N C
E
M F
O X
C
M O
X L
E Y
B T
A
B
M A
G G
IO
R
E
O C
T O
B E
R
M E
F
G
.D W
G
PLAN
NORTH
TRUE
NORTH 1/8" = 1'-0"G-004
1 B73 TEMPORARY ENTRANCE PLAN
SCALE: 1/8" = 1'-0"
0 4' 8' 16'
PLAN
NORTH
TRUE
NORTH 1/4" = 1'-0"G-004
2 ENLARGED TEMPORARY ENTRANCE PLAN
SCALE: 1/4" = 1'-0"
0 2' 4' 8' 1
T
E M
P O
R A
R Y
E N
T R
A N
C E
S
H E
E T
A D
D E
D
A M
E N
D M
E N
T
J A
N
A
M E
N D
M E
N T
J A
N
R
E V
IS
E
D K
E Y
N O
T E
A N
D D
R A
W
IN
G
CI001FTFA20DR04
EN
ER
A
L C
IV
IL
N O
TE
S
C . H
AT
C
H
ER
D . H
U
IS
M
AN
C . M
AS
O
N
A.
M
O R
AL
ES
M
EF
2C I0
.D
W G
O
CT
O
C
TO
BE
R
GENERAL CIVIL NOTES
A
SHEET
IDENTIFICATION
US Army Corps of Engineers ® Mobile District
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D
ES
IG
N
ED
B
Y:
BU
LL
O
CK
T
IC
E
AS
SO
CI
AT
ES
E.
C
ER
VA
NT
ES
S
TR
EE
T, S
UI
TE
B
PE
NS
AC
O
LA
, F
LO
RI
DA
2 3 4 5
B
C
D
D R
A W
N B
Y:
SB
M
T B
Y:
PL
O
T
SC
A
LE
SI
ZE
C K
D B
Y:
PL
O
T D
A
TE
D A
TE
SO
LI
C
IT
A
TI
O N
N O
C O
N
TR
A C
T N
O
PR
O
JE
C
T N
U M
B
ER
FI
LE
N A
M E:
M A
R K
D
ES
C R
IP
TI
O N
D A
TE
A
PP
R
1:
x
M O
B
IL
E D
IS
TR
IC
T
M O
B
IL
E, A
LA
B
A M
A
M
EF
EG
LI
N
AI
R
FO
RC
E
BA
SE
, F
LO
RI
DA
BU
IL
DI
NG
LA
B
EX
PA
NS
IO
N
V:
\2
6\ ac tiv e\
0\ ci vil
\d ra w in g\
_a m en dm en t_ ds gn
\s he et _f ile s\
M
EF
2C I0
.d w g
/0 1/
:4
AM B
y:
Ha tc he r, C ha nd le r
AMENDMENT 0003
AM
EN
DM
EN
T
ER
OS
IO
N
CO
NT
RO
L N
OT
ES
AN
D
6 R
EV
IS
ED
JA
N
CS
M
AM
EN
DM
EN
T
SP
EC
IA
L R
EQ
UI
RE
ME
NT
N
OT
E 2 R
EV
IS
ED
JA
N
CS
M
GENERAL:
1. BENCHMARK FOR CONSTRUCTION HAS BEEN PROVIDED ON SHEET V-102.
2. SHOP DRAWINGS OF ALL MATERIALS BEING USED SHALL BE SUBMITTED AS
PER SPECIFICATI0NS (SUBMITTALS).
3. ANY PENALTIES, STOP WORK ORDERS OR ADDITIONAL WORK RESULTING
FROM THE CONTRACTOR BEING IN VIOLATION OF THE REQUIREMENTS
ABOVE, SHALL BE FULLY BORNE BY THE CONTRACTOR.
4. PRIOR TO THE START OF ANY CONSTRUCTION ACTIVITY IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE VARIOUS UTILITIES AND TO
MAKE THE NECESSARY ARRANGEMENTS FOR ANY RELOCATION OF THESE
UTILITIES WITH THE OWNER OF THE UTILITY. THE CONTRACTOR SHALL
EXERCISE CAUTION WHEN CROSSING UNDERGROUND UTILITIES, WHETHER
SHOWN ON THE PLAN OR LOCATED BY THE UTILITY COMPANY. ALL UTILITIES
WHICH INTERFERE WITH THE PROPOSED CONSTRUCTION SHALL BE
BROUGHT TO THE ATTENTION OF THE COR FIRST.
5. THE SEQUENCE OF CONSTRUCTION SHALL BE SUCH THAT ALL
UNDERGROUND INSTALLATIONS OF EVERY KIND, INCLUDING LANDSCAPE
SPRINKLERS LINES, SHALL BE PLACED BENEATH THE PAVEMENT AND ITS
EDGES PRIOR TO THE CONSTRUCTION OF THE PAVEMENT. THE PAVEMENT
SHALL NOT BE CUT WITHOUT PRIOR APPROVAL OF THE COR.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PREVENTING ANY
CONSTRUCTION ACTIVITIES FROM TAKING PLACE OUTSIDE OF THE LIMITS OF
CONSTRUCTION SHOWN ON THE PLANS. ANY ON-SITE OR OFFSITE AREAS
DISTURBED BY CONTRACTOR OR SUB CONTRACTOR (EQUIPMENT AND/OR
PERSONNEL VEHICLES) SHALL BE RESTORED TO ORIGINAL CONDITION OR
BETTER.
7. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE EXISTING SITE
CONDITIONS OF SOIL PRIOR TO NOTICE TO PROCEED. CONTRACTOR TO
DETERMINE IF ANY OFF SITE MATERIALS WILL NEED TO BE IMPORTED TO
ACHIEVE THE GRADES SPECIFIED ON THE PLANS.
8. CONTRACTOR TO PERFORM FIRE FLOW TEST ON ALL ADJACENT FIRE
HYDRANTS. FINAL FLOW TESTS AT THE END OF THE PROJECT WILL BE
REQUIRED ON ALL NEW FIRE HYDRANTS INSTALLED.
9. ALL PERMITTING AND REGULATORY COORDINATION MUST BE CONDUCTED
THROUGH THE EGLIN AFB CIVIL ENGINEER WITH THE EXCEPTION OF THE
NPDES CONSTRUCTION PERMIT, WHICH THE CONTRACTOR MUST
COORDINATE DIRECTLY WITH FDEP, SEE EROSION CONTROL NOTE 6, THIS
SHEET, AND SPECIFICATION SECTION 01 00 00. ADDITIONAL SPECIAL
CONTRACT REQUIREMENTS AND 01 57 19 TEMPORARY ENVIRONMENTAL
CONTROLS. THE CONTRACTOR IS NOT TO CONTACT OR COORDINATE ANY
OTHER PERMITTING / REGULATORY ACTIVITY WITHOUT PRIOR APPROVAL BY
EGLIN AFB.
DEMOLITION:
1. THE CONTRACTOR SHALL OBTAIN NECESSARY PERMITS AND LICENSES FOR
PERFORMING THE DEMOLITION WORK AND SHALL FURNISH A COPY OF SAME
TO THE COR PRIOR TO COMMENCING THE WORK. THE CONTRACTOR SHALL
COMPLY WITH THE REQUIREMENTS OF THE PERMITS.
2. THE CONTRACTOR SHALL NOTIFY ALL UTILITY COMPANIES OR LOCAL
AUTHORITIES FURNISHING ELECTRICAL, POWER SERVICE SO THEY CAN
REMOVE, RELOCATE, DISCONNECT, CAP OR PLUG THEIR EQUIPMENT IN
ORDER TO FACILITATE DEMOLITION. ALL OTHER UTILITIES (WATER,
TELEPHONE OR SEWER) SHALL BE DISCONNECTED, CAPPED OR PLUGGED BY
THE CONTRACTOR AS DIRECTED BY COR REPRESENTATIVE.
3. THE PAVING MARKED FOR DEMOLITION WHICH INCLUDES ALL ASPHALT,
CONCRETE, BASE, AND RETAINING WALLS (INCLUDING THE FOOTERS) SHALL
BE REMOVED.
4. SAW-CUT A SMOOTH STRAIGHT EDGE ON ANY PAVEMENT PROPOSED FOR
DEMOLITION PRIOR TO ITS REMOVAL. PRIOR TO CONNECTING PROPOSED
PAVEMENT TO EXISTING PAVEMENT, THE CONTRACTOR SHALL ENSURE THAT
THE EDGE OF THE EXISTING PAVEMENT IS STRAIGHT AND UNIFORM PRIOR TO
REPAVING.
5. ALL MATERIAL SUCH AS ASPHALT AND CONCRETE SHALL BE STOCKPILED
AND REUSED ON SITE WHERE PRACTICAL. ALL EXCESS WASTE / RECYCLED
MATERIAL NOT RE-USED SHALL BE PROPERLY DISPOSED OF OFF BASE AT AN
APPROVED FACILITY.
OTHER UTILITY INFORMATION:
1. CONTRACTOR SHALL APPLY FOR AN EGLIN AFB DIG PERMIT BEFORE ANY
EXCAVATION IS BEGUN ON THE PROJECT.
2. LANDSCAPING SHALL NOT BE LOCATED WITHIN 3 FEET OF ANY FIRE HYDRANT
AND/OR FIRE DEPARTMENT CONNECTION.
3. WATER FOR FIRE FIGHTING PURPOSES SHALL BE AVAILABLE PRIOR TO
COMBUSTIBLES BEING BROUGHT ON SITE.
STORM DRAINAGE CONSTRUCTION NOTES:
1. UNLESS OTHERWISE NOTED, ALL STORM STRUCTURES SHALL MEET FDOT
STANDARDS.
2. UNLESS OTHERWISE NOTED ON THE PLANS STORM INLETS, MANHOLES, AND
CATCH BASINS SHALL BE PRE-CAST REINFORCED CONCRETE STRUCTURES
OR APPROPRIATE HDPE STRUCTURES SHALL BE REQUIRED AT EACH CHANGE
OF PIPE SIZE, CHANGE IN PIPE DIRECTION, OR PIPE MATERIAL.
3. ORDER OF CONSTRUCTION ACTIVITIES SHALL BE APPROVED BY COR PRIOR
TO CONSTRUCTION.
EARTHWORK, GRADING, STABILIZATION, PAVING AND DRAINAGE:
1. ALL ORGANIC SOILS BELOW UTILITY TRENCHES, PAVEMENT AND BUILDINGS,
SHALL BE REMOVED AND REPLACED WITH SUITABLE MATERIAL AND
COMPACTED TO NO LESS THAN 95% OF THE MODIFIED PROCTOR MAXIMUM
DENSITY (ASTM D-1557).
2. ALL PAVEMENT MARKINGS SHALL BE NON-REFLECTORIZED PAINT UNLESS
OTHER WISE NOTED.
3. THE REINFORCED CONCRETE PIPE SHALL BE CLASS III WITH WALL THICKNESS
"B" CONFORMING TO ASTM C - 76 OR AWWA 302 - 74 AND GASKETS SHALL BE
IN ACCORDANCE WITH ASTM C - 443 OR ASTM D - 412.
4. ALL PIPE CALL OUTS ARE MEASURED CENTER LINE TO CENTER LINE FOR
MANHOLES AND INLETS AND FROM THE END OF THE PIPE FOR MITERED END
SECTIONS.
5. DEWATERING MAY BE REQUIRED. SPECIAL CONDITIONS WILL BE NECESSARY
FOR DEWATERING IF REQUIRED (SEE SPECIFICATIONS).
6. ALL UTILITY PIPES SHALL HAVE 3 FEET MINIMUM COVER UNLESS OTHERWISE
SPECIFIED IN PLANS.
7. PLANS AND SPECIFICATIONS REQUIRE THAT COMPACTED BACKFILL BE
PLACED ALONG SIDE OF AND OVER ALL UTILITIES. TESTING SHALL BE PER
ASUS SPECIFICATIONS AND DETAILS AND CONTRACT SPECIFICATION
SECTION 31 00 00 - EARTHWORK .
8. INSTALL AND MAINTAIN GRASS OR SOD ON EXPOSED SLOPES WITHIN 48
HOURS OF COMPLETED FINAL GRADES, AS NOTED ON PLANS, AND AT ANY
OTHER TIME AS NECESSARY TO PREVENT EROSION, SEDIMENTATION OR
TURBID DISCHARGES TO ANY DOWNSTREAM WATER BODY, WETLAND, OR
OFF-SITE PROPERTY. SODDING ON SLOPES 3:1 AND STEEPER SHALL BE
STAKED.
9. THE CONTRACTOR SHALL TAKE ALL MEASURES NECESSARY TO CONTROL
TURBIDITY AND SEDIMENT INCLUDING, BUT NOT LIMITED TO, THE
INSTALLATION OF TURBIDITY BARRIERS AND SILT FENCES AT ALL LOCATIONS
WHERE THE POSSIBILITY OF TRANSFERRING SUSPENDED SOLIDS INTO THE
RECEIVING WATER BODY EXISTS DUE TO THE PROPOSED WORK. TURBIDITY
AND SEDIMENT BARRIERS MUST BE MAINTAINED AT ALL LOCATIONS UNTIL
CONSTRUCTION IS COMPLETED AND DISTURBED SOIL AREAS ARE
STABILIZED. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR
REMOVING THE BARRIERS. AT NO TIME SHALL THERE BE ANY OFFSITE
DISCHARGE WHICH VIOLATES THE WATER QUALITY STANDARDS IN
CHAPTERS 62-302 AND 62-4, FLORIDA ADMINISTRATIVE CODE.
EROSION CONTROL NOTES:
1. TEMPORARY STABILIZATION IS REQUIRED OF ALL SOIL LEFT BARE. MAXIMUM
TIME FOR BARE SOIL WITHOUT COVER WILL BE 14 DAYS.
2. PERMANENT SOIL STABILIZATION REQUIRED FOR ALL DISTURBED AREAS OF
THE SITE. (NOTE: IT IS NOT ANTICIPATED THAT ANY SLOPES WILL BE
CONSTRUCTED ON THE PROJECT. THE INTENT IS THAT ALL DISTURBED
AREAS SHALL BE REPAIRED WITH SOD).
3. STORMWATER INLETS AND STRUCTURES SHOULD BE PROTECTED FROM SOIL
DEPOSITION FIRST, TO PREVENT SOIL LOSS DURING THE CONSTRUCTION
PROCESS.
4. REQUIRED INSPECTIONS BY CONTRACTOR DURING CONSTRUCTION:
a. ONCE EACH WEEK OR WITHIN 24 HRS OF A STORM EVENT
(GREATER THAN 1/2 IN.) INSPECT ALL CONTROL MEASURES.
b. REPAIR ALL DAMAGED AREAS WITHIN 24 HRS OF DISCOVERY.
c. REMOVE ANY BUILT-UP SEDIMENT AROUND FENCES THAT
REACHES 1/3 OF THE SILT FENCE HEIGHT, REMOVE SEDIMENT
THAT COLLECTS IN DRAINAGE BASINS AND EXFILTRATION
TRENCHES.
d. SILT FENCES SHOULD BE INSPECTED FOR DEPTH OF SEDIMENT
AND TEARS TO INSURE FABRIC HAS NOT PULLED AWAY FROM
POSTS.
e. INSPECT ALL TEMPORARY AND PERMANENT SOIL STABILIZATION
FOR WASHOUTS OR BARE SPOTS.
f. INSPECTION REPORTS MUST BE AVAILABLE FOR INSPECTION AT
ALL TIMES. THE SITE SUPERINTENDENT OR QUALIFIED
STORMWATER INSPECTOR SHALL CONDUCT ALL INSPECTIONS
AND MAINTAIN REPORTS.
g. DATES OF ALL MAJOR GRADING ACTIVITIES MUST BE RECORDED
AND MAINTAINED WITH SITE INSPECTIONS WHEN MAJOR GRADING
HAS CEASED IN ANY AREA, THE DATE MUST ALSO BE RECORDED.
h. INSPECTION AND RECORD KEEPING SHALL BE IN ACCORDANCE
WITH THE PROJECT NPDES PERMIT REQUIRED TO BE OBTAINED
THROUGH FDEP.
5. GOOD HOUSEKEEPING. THE SITE SHOULD BE KEPT IN AN ORDERLY FASHION,
THE CONTRACTOR SHALL INSURE THE FOLLOWING ITEMS ARE ADDRESSED.
a. AN EFFORT TO STORE ONLY WHAT IS NEEDED ON THE SITE.
b. KEEP ALL STORED MATERIALS IN A NEAT AND ORDERLY FASHION
IN THE ORIGINAL CONTAINERS WHEN POSSIBLE.
c. FOLLOW ALL MANUFACTURERS RECOMMENDED PROCEDURES
FOR DISPOSAL OF WASTE MATERIAL.
d. INSPECT DAILY TO ENSURE WASTE MATERIAL IS DISPOSED OF
PROPERLY.
6. THIS PROJECT HAS LESS THAN ONE ACRE OF DISTURBED SOIL AND WILL NOT
REQUIRE AN NPDES PERMIT.
SPILL CONTROL NOTES:
1. IN ADDITION TO THE GOOD HOUSEKEEPING AND MATERIAL MANAGEMENT
PRACTICES DISCUSSED IN THE PREVIOUS NOTES OF THIS PLAN, THE
FOLLOWING PRACTICES WILL BE FOLLOWED FOR SPILL PREVENTION AND
CLEANUP IAW PROJECT SPECIFICATION SECTION 01 57 19.
a. ALL SPILLS WILL BE REPORTED TO THE AIR FORCE IMMEDIATELY
TO EGLIN AFB ENVIRONMENTAL DEPARTMENT (850.240.1628)
PRIOR TO ANY CLEAN UP, AND IF AN IMMEDIATE EMERGENCY
CALL 911 FIRST. POINT OF CONTACT IS ROBERT (BRUCE)
STIPPICH.
b. ALL SPILL PREVENTION, CONTROL, CLEAN UP AND/OR DISPOSAL
SHALL BE IAW PROJECT SPECIFICATION SECTION
01 57 19.
SURVEY:
1. HORIZONTAL COORDINATES BASED ON FLORIDA STATE PLANE - NORTH ZONE
(NAD83), US SURVEY FEET. SURVEY PERFORMED BY SAM, LLC.
2. ELEVATIONS ARE BASED ON NORTH AMERICAN VERTICAL DATUM OF 1988
(NAVD88) UNITED STATES COASTAL AND GEODETIC SURVEY (U.S.C. & G.S.),
AS DETERMINED BY SAM, LLC.
3. CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF ALL SURVEY AND
PROPERTY MONUMENTS. IF A MONUMENT IS DISTURBED, THE CONTRACTOR
SHALL CONTRACT WITH THE SURVEYOR OF RECORD FOR REINSTALLATION
OF THE MONUMENT.
4. ALL CONSTRUCTION LINES AND GRADES SHALL BE ESTABLISHED AND
MAINTAINED BY THE CONTRACTOR.
OUTAGES:
1. CONTRACTOR SHALL COORDINATE ALL UTILITY OUTAGES A MINIMUM OF 14
WORKING DAYS PRIOR TO THE SCHEDULED EVENT WITH COR
REPRESENTATIVE AND ASUS.
2. TEMPORARY UTILITY TIE-INS: FOR TEMPORARY UTILITY TIE-INS, (I.E.
CONTRACT'S TRAILER) ELECTRICITY AND POTABLE WATER ARE USUALLY
AVAILABLE ON EGLIN AND THE CONTRACTOR MAY TIE INTO THESE. BOTH
TIE-INS MUST MEET CODE REQUIREMENTS, MUST BE METERED WITH
APPROVED REMOTE READABLE METERS, AND THE CONTRACTOR SHALL
PROVIDE ALL MANPOWER/EQUIPMENT FOR THESE TIE-INS. EGLIN WILL ONLY
PERFORM THE FINAL ELECTRICAL TIE-IN TO BASE LINES; ALL OTHER WORK
WILL BE ACCOMPLISHED BY THE CONTRACTOR.
3. CONTRACTOR AWARDED THIS PROJECT IS RESPONSIBLE FOR MONITORING
CONSTRUCTION AND SUBMITTING TO THE DISTRICT/FDEP NOTICE OF
CONSTRUCTION COMMENCEMENT AND AS-BUILT CERTIFICATIONS FOR THE
PROJECT WHEN COMPLETED THE CONTRACTOR SHALL UTILIZE A
PROFESSIONAL ENGINEER TO MONITOR THE CONSTRUCTION ACTIVITIES FOR
THE WATER, SEWER AND STORM WATER IMPROVEMENTS PER THE
CONDITIONS OF THE APPROVED PERMITS. A PROFESSIONAL ENGINEER IS
REQUIRED BY PERMIT CONDITIONS TO SUBMIT THE CONSTRUCTION
COMPLETION PERMITS TO THE PERMITTING AGENCIES
GAS NOTES:
1. OKALOOSA GAS DISTRICT FACILITIES ARE AVAILABLE IN THE AREA ADJACENT
TO THE PROJECT SITE. NO IMPROVEMENTS ARE EXPECTED TO THE NATURAL
GAS INFRASTRUCTURE AS PART OF THE PROJECT.
2. SHORT DURATION OUTAGES WILL BE PERMITTED AND MUST BE APPROVED
BY THE CONTRACTING OFFICER, GAS MAIN SHUTDOWNS/OUTAGES SHALL
LAST NO LONGER THAN 60 MINUTES AND CAN OCCUR NO MORE THAN 2 TIMES
DURING THE CONSTRUCTION PERIOD.
SPECIAL REQUIREMENTS:
1. THIS PROJECT REQUIRES WORK ON THE EXISTING SANITARY SEWER
SYSTEM. THE EXISTING SANITARY SEWER SYSTEM MUST REMAIN IN
OPERATION DURING CONSTRUCTION. SHORT DURATION OUTAGES WILL BE
PERMITTED AND MUST BE APPROVED BY THE CONTRACTING OFFICER.
SANITARY SEWER SHUTDOWNS/OUTAGES SHALL LAST NO LONGER THAN 60
MINUTES, AND CAN OCCUR NO MORE THAN 4 TIMES DURING THE
CONSTRUCTION PERIOD. NO SHUTDOWN/OUTAGES SHALL OCCUR DURING
WET WEATHER EVENTS. THE CONTRACTOR SHALL COORDINATE ALL
SHUTDOWNS/OUTAGES WITH THE USACE AND BASE CIVIL ENGINEERING
OFFICE.
2. THE AMERICAN STATES UTILITIES SERVICES, INC. (ASUS) STANDARD DETAILS
AND SPECIFICATIONS ARE INCLUDED IN CONTRACT DOCUMENTS APPENDIX E
FOR REFERENCE TO THE WORK THEY WILL BE PERFORMING FOR
COORDINATION PURPOSES BY THE GENERAL CONTRACTOR. ANY WORK
PERFORMED BY THE CONTRACTOR SHALL BE GOVERNED BY DIVISIONS 01
THROUGH 41 OF THE PROJECT SPECIFICATIONS.
3. THE CONTRACTOR SHALL SUBMIT THE TEMPORARY AIRFIELD SECURITY
FENCING AND/OR FOREIGN OBJECT DEBRIS/DAMAGE (FOD) TEMPORARY
FENCING LOCATION FOR APPROVAL BY THE BASE ENGINEER AND SECURITY
FORCES PRIOR TO CONSTRUCTION ACTIVITIES COMMENCING AT THE
PROJECT SITE. THE TEMPORARY AIRFIELD SECURITY FENCE SHALL FOLLOW
DESIGN CRITERIA AS STATED ON THE ENGINEERING DESIGN MANUAL, EGLIN
AIR FORCE BASE (AFB) FLORIDA, FEBRUARY 2019 AND UFC 3-260-01,
APPENDIX B SECTION 14. THE TEMPORARY AIRFIELD SECURITY FENCING
SHALL BE INSTALLED BEFORE EXISTING FENCE CAN BE REMOVED.
TEMPORARY FENCE CANNOT BE WITHIN 50 FEET OF REDLINE. TEMPORARY
FENCE SHALL BE 6 FEET HIGH (MINIMUM) CHAIN LINK WITH TOP AND BOTTOM
RAILS AND MESH FABRIC SCREENING. THE TEMPORARY AIRFIELD SECURITY
FENCE SHALL HAVE MOUNTED SIGNS AT 100 FEET ON CENTERS IDENTIFYING
A “CONTROLLED AREA” SIGN LEGEND.
4. CONSTRUCTION ACTIVITIES ON THE AIRFIELD, IN PROXIMITY TO, OR
AFFECTING AIRCRAFT OPERATIONAL AREAS OR NAVIGABLE AIRSPACE, SHALL
BE COORDINATED WITH ALL AIRFIELD USERS BEFORE INITIATING SUCH
ACTIVITIES. IN ADDITION, BASIC RESPONSIBILITIES MUST BE IDENTIFIED AND
ASSIGNED PROCEDURES DEVELOPED AND DISSEMINATED TO INSTRUCT
CONSTRUCTION PERSONNEL IN AIRPORT PROCEDURES AND FOR
MONITORING CONSTRUCTION ACTIVITIES FOR CONFORMANCE WITH SAFETY
REQUIREMENTS. THESE AND OTHER SAFETY CONSIDERATIONS SHALL BE
ADDRESSED IN THE EARLIEST STAGES OF PROJECT FORMULATION AND
INCORPORATED IN THE CONTRACT SPECIFICATIONS, THE WORK ORDER
PROJECT REQUIREMENTS CHECKLIST, AND/OR OTHER PROJECT GUIDANCE
DOCUMENTS DEVELOPED FOR IN-HOUSE. CONSTRUCTION PROJECTS. THE
QUALITY ASSURANCE PERSONNEL, AIRFIELD MANAGER, AND CONTRACT
ADMINISTRATOR SHOULD CLOSELY MONITOR CONSTRUCTION ACTIVITY
THROUGHOUT ITS DURATION TO ENSURE CONTINUAL COMPLIANCE WITH
SAFETY REQUIREMENTS DELINEATED ON THE PROJECT PLANS. THE QUALITY
ASSURANCE PERSONNEL, AIRFIELD MANAGER, AND CONTRACT
ADMINISTRATOR SHOULD CLOSELY MONITOR CONSTRUCTION ACTIVITY
THROUGHOUT ITS DURATION TO ENSURE CONTINUAL COMPLIANCE WITH
SAFETY REQUIREMENTS.
5. EXISTING GOVERNMENT OWNED CONEX TRAILERS TO BE RELOCATED PRIOR
TO CONSTRUCTION WORK COMMENCING.
SS
x
SS
x
W x
W x
W x
W x
W x
W x
W x
Wx Wx
W x
W x
W x
W x
W x
W x
W x
W x
W x
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
E x
E x
E x
E x
E x
E x
E x
STEPS
RAMP
BUILDING 73
1 STORY BLOCK
F.F.E.=57.30'
BUILDING 71
2 STORY BLOCK
F.F.E.=56.06'
BUILDING 71
2 STORY BLOCK
F.F.E.=56.06'
E x
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
E x
E x
E x
E x
E x
E x
E x
E x
E x
Ex Ex
Ex Ex
COMM
Ex Ex
E x
E x
Ex
Wx Wx Wx Wx
CO
M
M
CO
M
M
C O
M M
CO
M
M
C O
M M
C O
M M
CO
M
M
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
E x
Ex
ExExEx
Ex Ex
Ex Ex
Ex Ex
Ex Ex
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
Ex Ex
Ex Ex
Ex Ex
E x
E x
E x
E x
Wx Wx Wx Wx Wx Wx Wx Wx Wx
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
ExExExExExExExExExExExExE x
E x
E x
E x
E x
E x
E x
E x
E x
E x
Ex Ex
E x
E x
E x
E x
E x
E x
Ex Ex
Ex Ex
Ex Ex E x
Ex Ex Ex Ex Ex
Ex
E x
E x
E x E x
E x
E x
E x
E x
E x
COMM
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
W x
Wx Wx Wx
G
G
G G
G
G
SDx SDx
Ex
Ex
E x
E x
SD x
SD x
SD x
SD x
Wx Wx Wx Wx
W x
W x
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
COMM
METAL DECK
WOOD DECK
WOOD DECK
METAL DECK
DECK OVERHANG
1 S
TO
RY
M
ET
AL
F.
F.
E.
=0
.00
2 S
TO
RY
M
ET
AL
F.
F.
E.
=0
.00
6"
CATV LINE
WALL
x
SD
x
E x
E x
E x
E x
E x
E x
ExEx
CO
M
M
COMM
BUILDING 85
2 STORY BRICK
F.F.E.=57.80'
AC
AC
BUILDING 78
1 STORY BRICK
F.F.E.=56.80'
WALKWAY
OVERHANG
CONEX
CONEX
CONEX
Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx
0 20' 40'
N
48 HOURS BEFORE DIGGING
1-800-432-4770
SUNSHINE STATE ONE CALL CENTER
CALL 811
TOLL FREE
OR
Know what's below.
Call before you dig.
CD101FTFA20DR04
O
VE
R A
LL
D
EM
O
LI
TI
O N
E
R O
SI
O
N C
O N
TR
O
L
PL
A N
S
C . H
AT
C
H
ER
D . H
U
IS
M
AN
C . M
AS
O
N
A.
M
O R
AL
ES
M
EF
2C D
1.
D W
G
O
CT
O
C
TO
BE
R
EXISTING PARKING LOT
SOD REMOVAL
DEMOLITION LEGEND
CONCRETE REMOVAL
STRUCTURE AND PAVEMENT
DEMOLITION
STRUCTURE(S) TO BE REMOVED BY GOVERNMENT PRIOR TO
CONTRACTOR COMMENCING WORK
UTILITY DEMOLITION
DEMOLITION NOTES
1. FOR EXISTING CONDITIONS LEGEND REFER TO SHEET V-101 AND V-102.
2. FOR PROPOSED WORK LEGEND REFER TO SHEET CI002.
3. REFER TO GC004 FOR PROPOSED FOREIGN OBJECT DEBRIS (FOD) AND
CONSTRUCTION FENCE LOCATIONS.
4. DOUBLE SAW CUT METHOD SHALL BE NECESSARY TO PREVENT
BINDING OF SAWING BLADE.
5. PCC DEMOLITION SHALL EXTEND TO THE NEAREST JOINT BASED ON
THE CONCRETE REMOVAL LIMITS.
6. CONTRACTOR SHALL COORDINATE UTILITY DEMOLITION WITH
CONTRACTING OFFICER. VERIFY ALL UTILITIES NOTED FOR
DEMOLITION HAVE BEEN SHUT OFF AND ABANDONED PRIOR TO ANY
WORK.
7. CONTRACTOR SHALL FIELD VERIFY ALL UTILITIES PRIOR TO BEGINNING
CONSTRUCTION ACTIVITIES. COORDINATE WITH CONTRACTING
OFFICER AND NOTIFY IMMEDIATELY OF ANY DISCREPANCY WITH
UTILITY LOCATIONS. EACH CONTRACTOR IS RESPONSIBLE FOR ANY
AND ALL DAMAGE TO UTILITIES CAUSED BY THEIR CONSTRUCTION
ACTIVITIES.
8. CONTRACTOR SHALL PROVIDE A TEMPORARY TRAFFIC CONTROL PLAN
FOR APPROVAL BY CONTRACTING OFFICER AND BASE ENGINEER
PRIOR TO STARTING CONSTRUCTION ACTIVITIES. TEMPORARY TRAFFIC
CONTROL PLAN SHALL COMPLY WITH FDOT MAINTENANCE AND
TRAFFIC DESIGN REQUIREMENTS, SPECIFICATIONS, AND 600 SERIES
INDEXES LATEST EDITION.
9. CONTRACTOR SHALL PERFORM AIRFIELD DEMOLITION AS NECESSARY
AT THE LOCATION OF AN EXISTING CONCRETE JOINT.
10. SEE SHEET GC004 FOR TEMPORARY CONSTRUCTION FENCE AND GATE
LOCATION.
CONEX TRAILERS, TYP. 6
(ANTICIPATED LOCATIONS AT
TIME OF PROJECT)
PAVEMENT MARKING REMOVAL
PROTECT EXISTING 10"
WATER LINE
PROTECT EXISTING
BURIED ELECTRIC LINE PROTECT EXISTING BURIED
ELECTRIC AND COMM LINES
PROTECT EXISTING BURIED
ELECTRIC AND COMM LINES
PROTECT EXISTING
BURIED ELECTRIC
AND COMM LINES PROTECT EXISTING
BURIED ELECTRIC LINE
PROTECT EXISTING WATER LINE
PROTECT EXISTING
COMM LINES
PROTECT EXISTING GAS LINE
1 OVERALL DEMOLITION PLAN
1" = 20'
A
SHEET
IDENTIFICATION
US Army Corps of Engineers ® Mobile District
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D
ES
IG
N
ED
B
Y:
BU
LL
O
CK
T
IC
E
AS
SO
CI
AT
ES
E.
C
ER
VA
NT
ES
S
TR
EE
T, S
UI
TE
B
PE
NS
AC
O
LA
, F
LO
RI
DA
2 3 4 5
B
C
D
D R
A W
N B
Y:
SB
M
T B
Y:
PL
O
T
SC
A
LE
SI
ZE
C K
D B
Y:
PL
O
T D
A
TE
D A
TE
SO
LI
C
IT
A
TI
O N
N O
C O
N
TR
A C
T N
O
PR
O
JE
C
T N
U M
B
ER
FI
LE
N A
M E:
M A
R K
D
ES
C R
IP
TI
O N
D A
TE
A
PP
R
1:
x
M O
B
IL
E D
IS
TR
IC
T
M O
B
IL
E, A
LA
B
A M
A
M
EF
EG
LI
N
AI
R
FO
RC
E
BA
SE
, F
LO
RI
DA
BU
IL
DI
NG
LA
B
EX
PA
NS
IO
N
V:
\2
6\ ac tiv e\
0\ ci vil
\d ra w in g\
_a m en dm en t_ ds gn
\s he et _f ile s\
M
EF
2C D1
.d w g
/0 1/
:5
AM B
y:
Ha tc he r, C ha nd le r
EXISTING GOVERNMENT
OWNED CONEX TRAILERS
TO BE RELOCATED PRIOR
TO CONSTRUCTION WORK
COMMENCING (NIC)
PROTECT EXISTING
CONCRETE
REMOVE CONCRETE TO THE
NEAREST JOINT AS SHOWN.
CONTRACTOR TO VERIFY
LOCATION. IF SAW CUTTING
IS NECESSARY, USE DOUBLE
SAW CUT METHOD PER
UFC 3-260-02 & UFC 3-270-01.
DEMO EXISTING STAIRS AND FOUNDATION,
SEE ARCHITECTURAL & STRUCTURAL
DRAWINGS FOR ADDITIONAL INFORMATION
DEMO EXISTING BOLLARDS
B-1
B-2
REMOVE STEEL PLATING TO NEAREST JOINT AND FILL UNDERGROUND
VAULT WITH COMPACTED SAND AND AGGREGATE BASE COURSE TO
SUPPORT NEW CONCRETE PAVEMENT. CONSTRUCT CONCRETE
PARTITION AT REMOVAL LIMIT TO CLOSE VAULT.
STEEL COVER REMOVAL
EXISTING UNDERGROUND VAULT
WITH STEEL PLATE COVERS
PROTECT EXISTING
FIRE HYDRANT
TEMPORARY FENCE HAS
BEEN REMOVED FROM
THE SITE SINCE THE
TIME OF THE SURVEYREMOVE EXISTING FENCE
TO LIMITS OF DEMOLITION
.0 1.
A
M
EN
D M
EN
T
N
O
TE
F O
R T
EM
PO
R A
R Y
FE
N
C E
A D
D
ED
A N
D F
EN
C
E D
EM
O
LI
TI
O N
C
LA
R
IF
IC
A
TI
O
N
AMENDMENT 0003
.0 1.
REMOVE ABANDONED
ELECTRIC MANHOLE
AND FILL WITH
COMPACTED SUITABLE
BACKFILL
.0 1.
A
M
EN
D M
EN
T
EX
. E
LE
C
TR
IC
A
L M
H R
EM
O
VA
L
N O
TE
A
D D
ED
C
SM
C
SM
C
SM
MEG 55
.61
MEG 56
.07
MEG 55
.74
55.97
55.97
MEG 55.74
MEG 55.68
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
1.0%
MEG 55.25
STR #2
MODIFIED FDOT TYPE “E” INLET
INDEX #425-052
H-20 TRAFFIC RATING
TOP EL = 55.65
INV EL = 50.83 S
STR #1
FDOT TYPE “C” INLET
INDEX #425-052
TOP EL = 55.47
INV EL = 52.05 E
INV EL = 52.00 N
CO #03
CLEANOUT
TOP EL = 56.24
INV EL = 51.67 S
INV EL = 51.84 SE
INV EL = 51.67 N
CO #02
CLEANOUT
TOP EL = 56.23
INV EL = 51.56 S
INV EL = 51.56 SE
INV EL = 51.56 N
CO #01A
CLEANOUT
TOP EL = 56.24
INV EL = 51.34 S
INV EL = 51.59 SE
INV EL = 51.34 N
CO #01
CLEANOUT
TOP EL = 56.23
INV EL = 51.33 SE
INV EL = 51.14 N
STR #3
MODIFIED FDOT TYPE “E” INLET
INDEX #425-052
H-20 TRAFFIC RATING
TOP EL = 56.10
INV EL = 49.04 SE
CO #06
CLEANOUT
TOP EL = 55.80
INV EL = 49.50 S
INV EL = 49.50 W
INV EL = 49.50 N
CO #05
CLEANOUT
TOP EL = 55.47
INV EL = 49.36 S
INV EL = 49.36 NW
5 LF 6" PVC @ 1.32%
12 LF 8" PVC @ 1.00%
LF
8" P
VC
1.
7 LF 6" PVC @ 1.00%
6 LF 6" PVC @ 1.00%
8 LF 6" PVC @ 0.61%
LF
8" P
VC
1.
LF
8"
P
VC
0.
7 LF 6" PVC @ 1.00%
56.35
56.40
56.40
LF
8" P
VC
0.
MEG 55.75 MEG 55.75
MEG 55.79
MEG 55.77
22 LF 8" PVC @ 0.64%
LF
8" P
VC
1.
3 LF 6" PVC @ 4.62%
3 LF 6" PVC @ 4.66%
20 LF 8" PVC @ 1.56%
CO #07
CLEANOUT
TOP EL = 55.67
INV EL = 49.81 W
INV EL = 49.81 N
55.53
55.57
MEG 55.49
MEG 55.46 MEG 55.42
55.53 55.63
55.55
MEG 55.70
MEG 56.09
55.72
MEG 55.68
MEG 55.72
1.
0%
1.
8%
4.1%
3.7%
MEG 55.75
MEG 55.74
MEG 55.87
11 LF 8" PVC @ 1.10%
CO #08
CLEANOUT
TOP EL = 56.15
INV EL = 51.88 S
INV EL = 51.76 N
TOS 56.35
TOS 56.02
TOS 56.02
TOS 56.35
TOS 56.45
TOS 56.45
TOS 56.45
TOS 56.45
TOS 56.35
TOS 56.35
TOS 56.35
TOS 56.35
TOS 56.35TOS 56.35
TOS 56.35
TOS 56.35
TOS 56.35
TOS 56.35
TOS 56.35
TOS 56.35
TOS 56.40TOS 56.27
TOS 55.71
TOS 56.33
TOS 56.33
55.95
56.10
55.85
55.85
55.90
55.85
MEG 55.76
55.97
CG101FTFA20DR04
G R
A D
IN
G
D
R A
IN
A
G E
PL
A
N
C . H
AT
C
H
ER
D . H
U
IS
M
AN
C . M
AS
O
N
A.
M
O R
AL
ES
M
EF
2C G
1.
D W
G
O
CT
O
C
TO
BE
R
0 10' 20'
N
1 GRADING & DRAINAGE PLAN
1" = 10'
BUILDING 73
ADDITION
FFE = 56.47
EXISTING
BUILDING 73
FFE = 57.30
NOTES:
1. REFER TO SHEET V-101 FOR EXISTING SITE LEGEND
2. REFER TO SHEET CI002 FOR NEW WORK LEGEND
LEGEND
PROPOSED BUILDING
PROPOSED CONCRETE PAVEMENT
PROPOSED STORM STRUCTURE NOTES:
FDOT TYPE E INLET MODIFICATIONS (STR #2 & #3):
1. CAST-IN-PLACE WITH OPEN BOTTOM (NO FLOOR)
2. WALL DEPTH TO EXTEND 18 INCHES BELOW PIPE INVERT.
3. UNDERLAY STRUCTURE WITH FDOT TYPE D3, CLASS “A”
GEOTEXTILE ON TOP OF UNDISTURBED SOIL. NO SEAMS
BENEATH FLOOR OPENING. BEND FABRIC UP ALL EXTERIOR
SIDES OF FINISHED STRUCTURE AND RETAIN WITH BACKFILL.
4. FILL BOTTOM 15 INCHES OF STRUCTURE WITH FDOT #57
COARSE AGGREGATE.
5. STEEL OR CAST IRON GRATE MAY BE USED.
6. THE PROPOSED STRUCTURES #2 & #3 ARE PERCOLATION
CHAMBERS, WITH SOIL INTERFACE APPROXIMATELY 7 FEET
BELOW GROUND SURFACE.
A
SHEET
IDENTIFICATION
US Army Corps of Engineers ® Mobile District
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D
ES
IG
N
ED
B
Y:
BU
LL
O
CK
T
IC
E
AS
SO
CI
AT
ES
E.
C
ER
VA
NT
ES
S
TR
EE
T, S
UI
TE
B
PE
NS
AC
O
LA
, F
LO
RI
DA
2 3 4 5
B
C
D
D R
A W
N B
Y:
SB
M
T B
Y:
PL
O
T
SC
A
LE
SI
ZE
C K
D B
Y:
PL
O
T D
A
TE
D A
TE
SO
LI
C
IT
A
TI
O N
N O
C O
N
TR
A C
T N
O
PR
O
JE
C
T N
U M
B
ER
FI
LE
N A
M E:
M A
R K
D
ES
C R
IP
TI
O N
D A
TE
A
PP
R
1:
x
M O
B
IL
E D
IS
TR
IC
T
M O
B
IL
E, A
LA
B
A M
A
M
EF
EG
LI
N
AI
R
FO
RC
E
BA
SE
, F
LO
RI
DA
BU
IL
DI
NG
LA
B
EX
PA
NS
IO
N
V:
\2
6\ ac tiv e\
0\ ci vil
\d ra w in g\
_a m en dm en t_ ds gn
\s he et _f ile s\
M
EF
2C G
1.
dw g
/0 1/
2:
P M B y:
Ha tc he r, C ha nd le r
EXISTING
BUILDING 71
FFE = 56.06
EQUIPMENT PADS
(SEE MECHANICAL)
STANDARD CONCRETE SPLASH BLOCKFFE = 57.30
PROPOSED BUILDING RAMP
GROUND FLOOR
(LOW)
GROUND FLOOR
(HIGH)
ANTICIPATED CONEX CONTAINER
LOCATION
AREA RESERVED
FOR FUTURE
CONEX CONTAINERS
TOS XXX PROPOSED TOP OF SLAB ELEVATION
ELEV PROPOSED SPOT ELEVATION
MODIFIED FDOT TYPE E INLET
CG101
MODIFIED FDOT TYPE E INLET
CG101
PCCP FINISHED
GRADE
W
AL
L D
EP
TH
FDOT #57 COARSE
AGGREGATE
FDOT TYPE E INLET STRUCTURE
GRATE
4'-4" C-I-P
EYEBOLTS
SEE TABLE
#4 BARS @ 12"
CTRS.
3" CI.
HORIZONTAL WALL REINFORCING
SCHEDULES
WALL
DEPTH SCHEDULE
AREA
(IN.2/FT)
MAX. SPACING
BARS WWF
0' - 5' AI2 0.20 12" 8"
0' - 7.5' A6 0.20 6" 5"
7.5' - 10' B5.5 0.24 51 2" 5"
10' - 15' C6.5 0.37 61 2" 6"
FDOT TYPE D3, CLASS "A"
GEOTEXTILE FABRIC
2 MODIFIED FDOT TYPE E INLET
NTS
THICKENED CONCRETE TRANSITION TO
DOOR ELEVATION
THICKENED CONCRETE TRANSITION TO
DOOR ELEVATION
8" C-I-P
5'-
" C -I-
P
4'-4" C-I-P
PLAN
SECTION
3'-4"
4'- 6"
GRATE
.0 1.
A
M
EN
D M
EN
T
, R
EV
IS
IO
N T
O M
O D
IF
IE
D F
D O
T
TY
PE
E
IN
LE
T D
ET
A
IL
AMENDMENT 0003
UP
UP
GRAPHIC LEGEND
EXISTING WALL
EXISTING ROOM NAME / NUMBER
DESIGNATION
ROOM NAME
DEMOLISH
HR HAND RAIL
GR GUARD RAIL
EXISTING
ANTENNA
TOWER
UP
UP
UP
(SALVAGE) REMOVE AND
RELOCATE CELLPHONE
AND LAPTOP LOCKER
EXISTING HANGER (B71)
DEMOLISH EXISTING CANOPY
DEMOLISH EXISTING CONCRETE
STAIRS, RAMP, LANDING, &
GUARDRAILS
DEMOLISH EXISTING CONCRETE
RAMP, LANDING, & GUARDRAILS
MANTRAP
E101
CORR.
E103
COMM.
E104ADMIN. SECURITY
E102
CONF.
E105
LAB 3
E106
LAB 4
E107
LAB 2
E110
LAB 1
E111
MECH
E109
TLT
E108
DEMOLISH EXISTING STEEL STAIRS,
GUARDRAIL/HANDRAILS, STEEL POSTS,
AND CONCRETE PEDESTAL
FOUNDATIONS AFTER NEW STAIR IS
INSTALLED, APPROVED, & FUNCTIONAL
'-9
PROVIDE GUARDRAIL AT LOCATION
WHERE STAIR & GUARDRAIL IS REMOVED
AFTER EXISTING STAIR IS DEMOLISHED
PROVIDE NEW EMERGENCY EGRESS STAIR,
HANDRAIL/GUARDRAILS, STEEL POSTS, AND
CONCRETE FOUNDATION, SEE STRUCTURAL
REMOVE/MODIFY PORTION OF EXISTING
HANDRAIL/GUARDRAIL FOR NEW STAIR LOCATION
25'-2"
EXISTING DRIVE
EXISTING ELEVATED EMERGENCY
STAIR PLATFORM
AD101
PROVIDE NEW CONCRETE
SIDEWALK TO EXISTING
PAVING, SEE CIVIL
EDGE OF EXISTING
CONCRETE PAVING
CONCRETE FOOTING,
SEE STRUCTURAL
EXISTING STEEL PLATE
TRENCH COVER
CONCRETE PAVING,
SEE CIVIL
REMOVE EXISTING GUARDRAIL & KICK
PLATE TO 1'-0" FROM END OF PLATFORM
AD101
1' -0
" 1' -0
GOVERNMENT TO REMOVE GALVANIZED METAL
ICE BRIDGE CABLE RACEWAY, ASSOCIATED
SUPPORT STRUCTURES, AND MOUNTED DEVICES
1. GENERAL DEMOLITION WORK TO THE EXISTING BUILDING FOR
THE INSTALLATION OF NEW UTILITIES AND SERVICES SHALL BE
INCLUDED IN THE SCOPE OF WORK. SAW-CUTTING AND
EXCAVATION; FILLING AND PATCHING OF EXISTING WALLS AFTER
INSTALLATION OF NEW UTILITIES AND SERVICES SHALL ALSO BE
INCLUDED IN THE SCOPE OF WORK. REFER TO TELECOM
DRAWINGS FOR NEW UTILITIES AND SERVICES.
2. PATCHING OF EXISTING STUD WALLS AND GYPSUM
WALLBOARD TO REMAIN SHALL ALSO BE INCLUDED IN SCOPE OF
WORK.
3. REFER TO ELECTRICAL, PLUMBING AND MECHANICAL
DRAWINGS FOR ADDITIONAL DEMOLITION REQUIREMENTS.
DEMOLITION NOTES
AD101
AD101
HR & GR
C
LE
A R
3' -2
GALVANIZED STEEL GRATE
LANDING, TREADS, & RISERS,
PAINT, SEE STRUCTURAL
4 TREADS @ 11"
5 RISERS @ 7" 5'-0"
18 TREADS @ 11"
19 RISERS @ 7"
GALV. METAL RAILING, PAINT
HR & GR
25'-2"1'-0"
1' -0
1'
-0
CONCRETE FOOTING
BEYOND, SEE STRUCTURAL CONCRETE FOOTING
BEYOND, SEE STRUCTURAL
GALVANIZED STEEL GRATE
LANDING, PAINT, SEE STRUCTURAL
GALVANIZED STEEL STAIR
STRINGER, PAINT, SEE STRUCTURAL
3'-2"
STEEL ANGLE MOUNTED BRACKET
BOLTED TO STAIR STRINGER,
PAINT, SEE STRUCTURAL
1 1/2" DIA. RAIL POST, PAINT
1 1/2" DIA. TOP RAIL, PAINT
1 1/2" DIA. LOW RAIL, PAINT
1 1/2" 1 1/2"
1 1/2" DIA. HANDRAIL, PAINT
2 1/4" 2 1/4"
3/4" DIA. PICKET, PAINT
AD101
T
R E
A D
S
1"
R
IS
E
R S
T
R E
A D
S
1"
R
IS
E
R S
HR & GR
GALV. STEEL GRATE LANDING, TREADS,
& RISERS, PAINT, SEE STRUCTURAL
GALVANIZED METAL
RAILING, PAINT GALV. STEEL TUBE FRAMING,
PAINT, SEE STRUCTURAL
3' -6
GR
EXISTING PLATFORM
'-0
1" NOSING
HR
2' -1
0"
CONCRETE FOOTING, TYP.,
SEE STRUCTURAL
CONCRETE FOOTING, TYP.,
SEE STRUCTURAL
CONCRETE SIDEWALK,
SEE STRUCTURAL
EXISTING GUARDRAIL
4" O.C. MAX. TYP.
4'-0" O.C. MAX. TYP.
EXISTING GRADE, SEE CIVIL
FIELD VERIFY
4'-7"
EXISTING STEEL GUARDRAIL
EXISTING STEEL PLATFORM
GALVANIZED STEEL
GUARDRAIL, PAINT TO MATCH
EXISTING, SEE STRUCTURAL
EXISTING STEEL BEAM
AD101
1'-0"1'-0"
TO CENTER OF NEW
GUARDRAIL POST
GALVANIZED STEEL
GUARDRAIL, PAINT TO MATCH
EXISTING, SEE STRUCTURAL
AD101
EXISTING STEEL
GUARDRAIL
1' -0
EXISTING STEEL
PLATFORM
1'-0"
TO CENTER OF NEW
GUARDRAIL POST
TO CENTER OF NEW
GUARDRAIL POST
FIELD VERIFY
4'-7"
1'-0"
1' -0
GALVANIZED STEEL KICK
PLATE, PAINT TO MATCH
EXISTING, SEE STRUCTURAL EXISTING STEEL
PLATFORM
EXISTING STEEL
GUARDRAIL BEYOND
GALVANIZED STEEL GUARDRAIL,
POST & KICK PLATE, PAINT TO
MATCH EXISTING, SEE STRUCTURAL
EXISTING STEEL BEAM
EXISTING STEEL
KICK PLATE
1'-0"
TO CENTER OF NEW
GUARDRAIL POST
A
SHEET
IDENTIFICATION
US Army Corps of
Engineers ® Mobile District
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S
IG
N E
D B
Y
B U
L L
O C
K T
IC
E
A S
S O
C
IA
T E
S E
C
E R
V A
N T
E S
S T
R E
E T
P E
N S
A C
O L
A F
L O
R
ID
A
2 3 4 5
B
C
D
D R
A W
N B
Y
S B
M T
B Y
P L
O T
S C
A L
E
S
IZ
E
C K
D B
Y
P L
O T
D A
T E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
P R
O J
E C
T N
U M
B E
R
F
IL
E N
A M
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
:1 x
M O
B
IL
E D
IS
T
R
IC
T M
O B
IL
E
A
L A
B A
M A
O C
T
M
E F
AMENDMENT 0003
E G
L
IN
A
IR
F O
R C
E B
A S
E F
L O
R
ID
A B
U
IL
D
IN
G
L
A B
E X
P A
N S
IO
N
AD101FTFA20DR04
D E
M O
L
IT
IO
N
F L
O O
R P
L A
N
H A
N G
E R
S T
A
IR
M O
D
IF
IC
A
T
IO
N
M F
O X
C
M O
X L
E Y
B
M A
G G
IO
R
E
B T
A
O C
T O
B E
R
M E
F
A
D
.D W
G
PLAN
NORTH
TRUE
NORTH 1/8" = 1'-0"AD101
1 DEMOLITION & B.71 STAIR FLOOR PLAN
SCALE: 1/8" = 1'-0"
0 4' 8' 16'
PLAN
NORTH
TRUE
NORTH 1/4" = 1'-0"AD101
2 ENLARGED STAIR PLAN
3/4" = 1'-0"AD101
3 STAIR SECTION
1/4" = 1'-0"AD101
4 STAIR SECTION
NOTE: STAIR DESIGN TO BE +/- ONE TREAD AND
RISER BASED ON FIELD VERIFIED CONDITION
SCALE: 3/4" = 1'-0"
0 8" 1'-4" 2'-8"
SCALE: 1/4" = 1'-0"
0 2' 4' 8'
1/4" = 1'-0"AD101
GUARDRAIL
ELEVATION
1/4" = 1'-0"AD101
5 GUARDRAIL PLAN
3/4" = 1'-0"AD101
GUARDRAIL
SECTION 1
A
M E
N D
M E
N T
J A
N
C
L A
R
IF
IE
D
G O
V E
R N
M E
N T
D E
M O
L
IT
IO
N
W O
R K
GROUND FLOOR (LOW)
6"
MEZZANINE
17'-6"
A-141
P.T. 2X NAILER
LOW SLOPE MEMBRANE
ROOFING SYSTEM
GALV. METAL DECK,
SEE STRUCTRAL
R-30 RIGID INSULATION
1/2" GLASS MAT GYPSUM
SHEATHING ROOF BOARD
5/8" GLASS MAT GYPSUM
SHEATHING ROOF BOARD
STEEL BEAM, SEE STRUCTURAL
(2) LAYERS OF 5/8" TYPE "X" GYPSUM
WALLBOARD, SEAL TO DECK ABOVE
PREFINISHED METAL FLASHING
2 1/2" - 16GA GALV. METAL
STUDS, SEE STRUCTURAL
2 1/2" GALV. METAL FRAMING, TYP.
FILL CAVITY WITH BATT INSULATION, TYP.
SECURITY/STC 50 MIN.
ROOF/CEILING ASSEMBLY
(RAL# TL11-006, STC 56)
SECURITY/STC 50 MIN.
WALL ASSEMBLY
8" - 16GA GALV. METAL
STUDS, SEE STRUCTURAL
R-19 THERMAL BATT INSULATION
LAB 6
8" - 16GA GALV. METAL
STUDS, SEE STRUCTURAL
R-5 RIGID INSULATION
FLUID APPLIED AIR AND
MOISTURE BARRIER
(2) LAYERS OF 5/8" TYPE "X"
EXTERIOR GYPSUM SHEATHING
R-19 THERMAL BATT INSULATION
1" NOMINAL CEMENTITIOUS
STUCCO SYSTEM OVER
GALV. METAL LATH
3/4" - 10GA EXPANDED METAL
SECURITY MESH
STEEL WIND BEAM, SEE STRUCTURAL
CONCRETE SLAB, SEE STRUCTURAL
VAPOR BARRIER,
SEAL AT JOINTS,
SEE STRUCTURAL
CONCRETE APRON, SEE CIVIL
VARIES
ROOF
A
CONCRETE FOOTING,
SEE STRUCTURAL
4"
4"
3 1/4"
11 1/4"
STAINLESS STEEL TRANSITION FLASHING,
PAINT TO MATCH STUCCO
STUCCO WEEP SCREED
CLOSED CELL SPRAY
FOAM INSULATION
A-510
7 1/4"
1/
2"
1/
2"
7/8" - 18 GA. METAL FURRING
CHANNEL @ 24" O.C.
R-13 FIBERGLASS BATT INSULATION
BOTTOM OF STEEL BEAM BEYOND
5/8" TYPE "X" GYPSUM BOARD
6" - 18 GA. GALVANIZED METAL FRAMING
@ 48" O.C. MIN., SEE STRUCTURAL
5 3/4"
TO FACE OF BENT PLATE
2"
GROUND FLOOR (HIGH)
1'-4"
VARIES
EXISTING ROOF
VARIES
LOW ROOF
F
SECURITY/STC 50 MIN.
ROOF/CEILING ASSEMBLY
(RAL# TL11-006, STC 56)
CORR.
VAPOR BARRIER, SEAL AT
JOINTS, SEE STRUCTURAL
CONCRETE SLAB, SEE STRUCTURAL
CEILING AS SCHEDULED
CONCRETE FOOTING,
SEE STRUCTURAL
EXISTING HOLLOW
METAL DOOR & FRAME
2 1/2" GALV. METAL
STUD FRAMING
5/8" TYPE "X" GYPSUM
WALLBOARD
EXISTING CONCRETE & INFILLED
12" SMOOTH FACE CMU WALL
STEEL TUBE, SEE STRUCTURAL
PREFINISHED METAL FLASHING WITH
SLIP JOINT/ EXPANSION JOINT
P.T. WOOD NAILER
FLEXIBLE VAPOR RETARDER WITH
COMPRESSIBLE INSULATION
LOW SLOPE MEMBRANE WALL FLASHING
REPLACEMENT MEMBRANE ROOFING SYSTEM
LOW SLOPE MEMBRANE
ROOFING SYSTEM
GALV. METAL DECK,
SEE STRUCTRAL
R-30 RIGID INSULATION
1/2" GLASS MAT GYPSUM
SHEATHING ROOF BOARD
5/8" GLASS MAT GYPSUM
SHEATHING ROOF BOARD
STEEL BEAM, SEE
STRUCTURAL
P.T. 2X NAILER
PREFINISHED METAL FLASHING
2 1/2" - 16GA GALV. METAL
STUDS, SEE STRUCTURAL
2 1/2" GALV. METAL FRAMING, TYP.
FILL CAVITY WITH BATT INSULATION, TYP.
6"
GALV. METAL STUD FRAMING
14GA GALV. METAL BENT PLATE,
ANCHOR TO EXISTING WALL
(2) LAYERS 1/2" FIRE RETARDENT TREATED
PLYWOOD FOR METAL FLASHING & WALL
MEMBRANE ANCHOR SUBSTRATE
1" NOMINAL CEMENTITIOUS STUCCO
SYSTEM OVER GALV. METAL LATH
EXPANSION JOINT COVER,
EXTRUDED ALUMINUM RECIEVER
AND ELASTOMETRIC SEAL
CLOSED CELL SPRAY FOAM
INSULATION
A-141
NOTE: SEE 1/A-310 FOR MATERIALS
NOT IDENTIFIED ON THIS SECTION
EXISTING RAISED ACCESS FLOORING
0'-0"
EXISTING RECESSED SLAB
A-143
STC 50 MIN. EXPANSION JOINT, EXPANDING FOAM
SYSTEM WITH FACTORY APPLIED SILICONE FACING
±2'-0" TYP.
EXISTING RECESSED CONCRETE SLAB
STEEL TUBE BEYOND, SEE STRUCTURAL
11 1/4"
4"
4"
3 1/4"
GALVANIZED METAL CLIP WITH
VERTICAL SLOTTED HOLES TO
BRACE TOP OF WALL
7 1/4"
EXISTING SECURITY WALL
1/
2"
1/
2"
5 3/4"
TO FACE OF BENT PLATE
GROUND FLOOR (LOW)
6"
ROOF
28'-6"
MEZZANINE
17'-6"
4"
4"
3 1/4"
SECURITY/STC 50 MIN.
FLOOR/CEILING ASSEMBLY
(RAL# TL01/215, STC 60)
SECURITY/STC 50 MIN.
WALL ASSEMBLY
SECURITY/STC 50 MIN.
WALL ASSEMBLY
SECURITY/STC 50 MIN.
ROOF/CEILING ASSEMBLY
(RAL# TL11-006, STC 56)
P.T. 2X NAILER
LOW SLOPE MEMBRANE
ROOFING SYSTEM
GALV. METAL DECK,
SEE STRUCTRAL
R-30 RIGID INSULATION
1/2" GLASS MAT GYPSUM
SHEATHING ROOF BOARD
5/8" GLASS MAT GYPSUM
SHEATHING ROOF BOARD
STEEL BEAM, SEE
STRUCTURAL
8" - 16GA GALV. METAL
STUDS, SEE STRUCTURAL
R-5 RIGID INSULATION
FLUID APPLIED AIR AND
MOISTURE BARRIER
(2) LAYERS OF 5/8" TYPE "X"
EXTERIOR GYPSUM SHEATHING
R-19 THERMAL BATT INSULATION
CEILING AS SCHEDULED
CONCRETE SLAB,
SEE STRUCTURAL
VAPOR BARRIER, SEAL AT
JOINTS, SEE STRUCTURAL
CONCRETE APRON, SEE CIVIL
CONCRETE SLAB ON GALV.
METAL DECK, SEE STRUCTURAL
(2) LAYERS OF 5/8" TYPE "X" GYPSUM
WALLBOARD, SEAL TO DECK ABOVE
PREFINISHED METAL FLASHING
1" NOMINAL CEMENTITIOUS
STUCCO SYSTEM OVER GALV.
METAL LATH
CONCRETE FOOTING,
SEE STRUCTURAL
STAINLESS STEEL TRANSITION FLASHING,
PAINT TO MATCH STUCCO
8" - 16GA GALV. METAL
STUDS, SEE STRUCTURAL
R-19 THERMAL BATT INSULATION
STEEL BEAM, SEE STRUCTURAL
3/4" - 10GA EXPANDED METAL
SECURITY MESH
2 1/2" - 16GA GALV. METAL
STUDS, SEE STRUCTURAL
2 1/2" GALV. METAL FRAMING, TYP.
FILL CAVITY WITH BATT
INSULATION, TYP.
CAST IRON DOWNSPOUT TO CONNECT TO
UNDERGROUND STORMWATER PIPING, SEE CIVIL
PREFINISHED METAL GUTTER
AND DOWNSPOUT
1/2" / 1'-0"
LAB 7
MEZZANINE
2 1/2" - 16GA GALV. METAL
STUDS, SEE STRUCTURAL
2 1/2" GALV. METAL FRAMING, TYP.
FILL CAVITY WITH BATT
INSULATION, TYP.
STUCCO WEEP SCREED
11 1/4"
CLOSED CELL SPRAY FOAM
INSULATION
A-143
A-510
SIM
7 1/4"
5/8" TYPE "X" GYPSUM BOARD
RESILIENT ISOLATION CLIP (RSIC-1 OR EQUAL)
6" - 18 GA. GALVANIZED METAL FRAMING
@ 48" O.C. MIN., SEE STRUCTURAL
7/8" - 25 GA. METAL FURRING CHANNEL @ 24" O.C.
5/8" TYPE "X" GYPSUM BOARD
6" - 18 GA. GALVANIZED METAL FRAMING
@ 48" O.C. MIN., SEE STRUCTURAL
7/8" - 18 GA. METAL FURRING CHANNEL @ 24" O.C.
R-13 FIBERGLASS BATT INSULATION
1/
2"
1/ 2"
(2) LAYERS OF 5/8" TYPE "X" GYPSUM
WALLBOARD, SEAL TO DECK ABOVE
1/
2"
1/
4"
BOTTOM OF STEEL BEAM BEYOND
5 3/4"
TO FACE OF BENT PLATE
6 1/2"
STORMWATER PIPING,
SEE CIVIL
2"
A
SHEET
IDENTIFICATION
US Army Corps of
Engineers ® Mobile District
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S
IG
N E
D B
Y
B U
L L
O C
K T
IC
E
A S
S O
C
IA
T E
S E
C
E R
V A
N T
E S
S T
R E
E T
P E
N S
A C
O L
A F
L O
R
ID
A
2 3 4 5
B
C
D
D R
A W
N B
Y
S B
M T
B Y
P L
O T
S C
A L
E
S
IZ
E
C K
D B
Y
P L
O T
D A
T E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
P R
O J
E C
T N
U M
B E
R
F
IL
E N
A M
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
:1 x
M O
B
IL
E D
IS
T
R
IC
T M
O B
IL
E
A
L A
B A
M A
O C
T
M
E F
AMENDMENT 0003
E G
L
IN
A
IR
F O
R C
E B
A S
E F
L O
R
ID
A B
U
IL
D
IN
G
L
A B
E X
P A
N S
IO
N
A-310FTFA20DR04
W A
L L
S E
C T
IO
N
S
M F
O X
C
M O
X L
E Y
B
M A
G G
IO
R
E
B T
A
O C
T O
B E
R
M E
F
A
.D W
G
3/4" = 1'-0"A-310
2 WALL SECTION
3/4" = 1'-0"A-310
3 WALL SECTION
3/4" = 1'-0"A-310
1 WALL SECTION
SCALE: 3/4" = 1'-0"
0 8" 1'-4" 2'-8"
A
M E
N D
M E
N T
J A
N
R E
V
IS
E D
S T
C C
E
IL
IN
G
F R
A M
ROOF
28'-6"
1'-0"
7/ 8"
SECURITY/STC 50 MIN.
ROOF/CEILING ASSEMBLY
(RAL# TL11-006, STC 56)
LOW SLOPE MEMBRANE
ROOFING SYSTEM
GALV. METAL DECK,
SEE STRUCTRAL
R-30 RIGID INSULATION
1/2" GLASS MAT GYPSUM
SHEATHING ROOF BOARD
5/8" GLASS MAT GYPSUM
SHEATHING ROOF BOARD
STEEL BEAM, SEE
STRUCTURAL
(2) LAYERS OF 5/8" TYPE
"X" GYPSUM WALLBOARD,
SEAL TO DECK ABOVE
PREFINISHED METAL FLASHING
2 1/2" - 16GA GALV. METAL
STUDS, SEE STRUCTURAL
2 1/2" GALV. METAL FRAMING, TYP.
FILL CAVITY WITH BATT
INSULATION, TYP.
PREFINISHED METAL GUTTER
PREFINISHED METAL LOUVER, SEE MECHANICAL
A-611
A-611
PREFINISHED METAL
OVERHEAD COILING DOOR
PREFINISHED METAL
OHCD HOUSING
PREFINISHED PRE-ENGINEERED
METAL CANOPY
PREFINISHED METAL OHCD
HOUSING
1/ 2" 1/4" / 1'-0"
6 1/2"
VAPOR BARRIER, SEAL AT
JOINTS, SEE STRUCTURAL
CONCRETE SLAB,
SEE STRUCTURAL
CONCRETE FOOTING,
SEE STRUCTURAL
CONCRETE APRON, SEE CIVIL
ALUMINUM WALL BRACKETS, CONFIGURE ANCHOR BOLTS
HORIZONTALLY AT BRACKET TO MINIMIZE HEIGHT OF
BRACKET IF MORE THAN ONE BOLT PER BRACKET REQ.
PREFINISHED ALUMINUM TUBE SUPPORTS
PRE-ENGINEERED CANOPY DECK
ALUMINUM SADDLE BRACKET
PREFINISHED METAL WALL FLASHING
PREFINISHED ALUMINUM
BEAM/GUTTER, TYP.
PROVIDE SUPPORT
GALV. METAL STUD
FRAMING AS REQUIRED
FOR OVERHEAD DOORS
20'-11"
CANOPY (LOW-END)
LAB 6
P.T. 2X NAILER
STEEL WIND BEAM, SEE STRUCTURAL
GALV. METAL STUD BOX BEAM,
SEE STRUCTURAL
4" 4" 3 1/4"
11 1/4"
CANOPY DEPTH
4'-0"
CLOSED CELL SPRAY FOAM INSULATION
'-5
STEEL ANGLE, SEE
STRUCTURAL
ANCHOR BY PRE-ENGINEERED CANOPY MFR.,
ANCHOR SYSTEM TO BE COMPATIBLE W/ SUBSTRATE
AND STUCCO W/ STUD BLOCKING ANCHOR POINT
GALV METAL STUD BLOCKING, SEE STRUCTURAL
SECURITY/STC 50 MIN.
WALL ASSEMBLY
NOTE: SEE 1/A-310 FOR MATERIALS
NOT IDENTIFIED ON THIS SECTION
A-143
1/
2"
1/ 2"
2 1/2"
1/4" PER FOOT SLOPE
'-5
7 1/4"
18'-11"
BOT. PLATE
5 3/4"
TO FACE OF BENT PLATE
SIM
GROUND FLOOR (LOW)
6"
MEZZANINE
17'-6"
C C.6
14GA GALV. METAL CLIP
SECURITY/STC 50 MIN.
FLOOR/CEILING ASSEMBLY
(RAL# TL01/215, STC 60)
SECURITY/STC 50 MIN.
WALL ASSEMBLY
SECURITY/STC 50 MIN.
ROOF/CEILING ASSEMBLY
(RAL# TL11-006, STC 56)
SECURITY/STC 50 (MIN.)
SHAFT WALL ASSEMBLY
(RAL-OT-04-020, STC 51)
SECURITY/STC 50 MIN.
WALL ASSEMBLY
LOW SLOPE MEMBRANE
ROOFING SYSTEM
GALV. METAL DECK,
SEE STRUCTRAL
R-30 RIGID INSULATION
1/2" GLASS MAT GYPSUM
SHEATHING ROOF BOARD
5/8" GLASS MAT GYPSUM
SHEATHING ROOF BOARD
STEEL BEAM, SEE
STRUCTURAL
(2) LAYERS OF 5/8" TYPE
"X" GYPSUM WALLBOARD,
SEAL TO DECK ABOVE
3 1/2" SOUND ATTENUATION INSULATION
3 5/8" GALV. METAL STUD FRAMING
4" GALV. METAL
JAMB STRUT
1" GYPSUM LINER PANEL
(2) LAYERS OF 5/8" TYPE
"X" GYPSUM WALLBOARD
STEEL BEAM, SEE
STRUCTURAL
STEEL BEAM, SEE
STRUCTURAL
CEILING AS SCHEDULED
CONCRETE SLAB ON GALV.
METAL DECK, SEE STRUCTURAL
STEEL ANGLE MOUNTING BRACKET,
WELD TO EDGE OF BENT PLATE
METAL GUARDRAIL, PAINTED
(2) LAYERS OF 5/8" TYPE
"X" GYPSUM WALLBOARD,
SEAL TO DECK ABOVE
3 1/2" SOUND
ATTENUATION INSULATION
6" GALV. METAL
STUD FRAMING
2 1/2" GALV. METAL
FRAMING, TYP.
FILL CAVITY WITH BATT
INSULATION, TYP.
1 5/8" GALV. METAL
FRAMING, TYP.
GALV. METAL STUD BOX
HEADER, SEE STRUCTURAL
STC 45 RATED HOLLOW
METAL DOOR AND FRAME
LAB 9
MEZZANINE
STC DOOR THRESHOLD
VAPOR BARRIER, SEAL AT
JOINTS, SEE STRUCTURAL
CONCRETE SLAB,
SEE STRUCTURAL
3' -6
M
IN
SOUND ATTENUATION
INSULATION, FILL
CAVITY COMPLETELY
6"
1/2"
C.2
'-0
A-510
5/8" TYPE "X" GYPSUM BOARD
RESILIENT ISOLATION CLIP (RSIC-1 OR EQUAL)
6" - 18 GA. GALVANIZED METAL FRAMING
@ 48" O.C. MIN., SEE STRUCTURAL
7/8" - 25 GA. METAL FURRING
CHANNEL @ 24" O.C.
BOTTOM OF STEEL
BEAM BEYOND
1/
4"
1/
2"
1/ 4"
1/
2"
1/
2" 5/8" TYPE "X" GYPSUM BOARD
6" - 18 GA. GALVANIZED METAL FRAMING
@ 48" O.C. MIN., SEE STRUCTURAL
7/8" - 18 GA. METAL FURRING CHANNEL @ 24" O.C.
R-13 FIBERGLASS BATT INSULATION
SIM
COMPLETELY FILL VOID BETWEEN
TOP TRACK AND DECK WITH SOUND
ATTENUATION INSULATION
A
SHEET
IDENTIFICATION
US Army Corps of
Engineers ® Mobile District
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S
IG
N E
D B
Y
B U
L L
O C
K T
IC
E
A S
S O
C
IA
T E
S E
C
E R
V A
N T
E S
S T
R E
E T
P E
N S
A C
O L
A F
L O
R
ID
A
2 3 4 5
B
C
D
D R
A W
N B
Y
S B
M T
B Y
P L
O T
S C
A L
E
S
IZ
E
C K
D B
Y
P L
O T
D A
T E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
P R
O J
E C
T N
U M
B E
R
F
IL
E N
A M
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
:1 x
M O
B
IL
E D
IS
T
R
IC
T M
O B
IL
E
A
L A
B A
M A
O C
T
M
E F
AMENDMENT 0003
E G
L
IN
A
IR
F O
R C
E B
A S
E F
L O
R
ID
A B
U
IL
D
IN
G
L
A B
E X
P A
N S
IO
N
A-311FTFA20DR04
W A
L L
S E
C T
IO
N
S
M F
O X
C
M O
X L
E Y
B
M A
G G
IO
R
E
B T
A
O C
T O
B E
R
M E
F
A
.D W
G
3/4" = 1'-0"A-311
1 WALL SECTION
3/4" = 1'-0"A-311
2 WALL SECTION SCALE: 3/4" = 1'-0"
0 8" 1'-4" 2'-8"
A
M E
N D
M E
N T
J A
N
R E
V
IS
E D
S T
C C
E
IL
IN
G
F R
A M
GROUND FLOOR (HIGH)
1'-4"
D
3 5/8" GALV. METAL
STUD FRAMING
(2) LAYERS OF 5/8" TYPE "X"
GYPSUM WALL BOARD,
EXTEND TO SLAB BELOW
3/4" - 10GA EXPANDED METAL SECURITY
MESH, END METAL MESH AT HIGHER SLAB
CONCRETE SLAB, SEE STRUCTURAL
CONCRETE SLAB,
SEE STRUCTURAL
VAPOR BARRIER, SEAL AT JOINTS
(2) LAYERS OF 5/8" TYPE "X"
GYPSUM WALL BOARD
SEALANT
LAB 10
116LAB 8
3 5/8" GALV. METAL STUD NAILER FOR
METAL MESH ATTACHMENT
3 1/2" SOUND ATTENUATION
INSULATION
SECURITY/STC 50 MIN.
WALL ASSEMBLY
MEZZANINE
17'-6"
CEILING AS SCHEDULED
STEEL BEAM, SEE
STRUCTURAL
3 5/8" GALV. METAL STUD FRAMING
5/8" TYPE "X" GYPSUM WALL BOARD
CONCRETE SLAB ON GALV.
METAL DECK, SEE STRUCTURAL
CONTINUOUS STEEL BENT
PLATE, SEE STRUCTURAL
1" X 1" BOTTOM RAIL
3/4" X 3/4" PICKET
1 1/2" X 1 1/2" POST
1 1/2" X 1 1/2" TOP RAIL
LAB 6
MEZZANINE
1" 2"
1/2"
3' -6
M
IN
1/
2"
1 1/2"
STEEL ANGLE MOUNTING BRACKET,
WELD TO EDGE OF BENT PLATE
3 5/8" GALV. METAL FRAMING, TYP.
18GA GALV. METAL
CLIP ANGLE
MEZZANINE
17'-6"
FILL CAVITY WITH BATT INSULATION, TYP.
(2) LAYERS OF 5/8" TYPE "X" GYPSUM
WALL BOARD, SEAL TO DECK ABOVE
3 1/2" SOUND ATTENUATION INSULATION
2 1/2" GALV. METAL FRAMING
3 5/8" GALV. METAL FRAMING
CONCRETE SLAB ON GALV.
METAL DECK, SEE STRUCTURAL
CONTINUOUS STEEL BENT
PLATE, SEE STRUCTURAL
STEEL BEAM, SEE STRUCTURAL
3 1/2" SOUND
ATTENUATION INSULATION
3 5/8" GALV. METAL FRAMING
2 1/2" SOUND ATTENUATION INSULATION
SECURITY/STC 50 MIN.
WALL ASSEMBLY
SECURITY/STC 50 MIN.
WALL ASSEMBLY
2 1/2" GALV. METAL FRAMING
2 1/2" GALV. METAL FRAMING
COMPLETELY FILL VOID BETWEEN
TOP TRACK AND DECK WITH SOUND
ATTENUATION INSULATION
MEZZANINE
17'-6"
2.8
2" M
IN
ALIGN 2 1/2" METAL STUD WITH FACE OF
OUTSIDE FACE OF GYPSUM BOARD BELOW
1/
4"
1/ 2"
(2) LAYERS OF 5/8" TYPE "X" GYPSUM
WALL BOARD, SEAL TO DECK ABOVE
CONCRETE SLAB ON GALV.
METAL DECK, SEE STRUCTURAL
3 1/2" SOUND ATTENUATION INSULATION
3 5/8" GALV. METAL FRAMING
SECURITY/STC 50 MIN.
WALL ASSEMBLY
STEEL BEAM, SEE STRUCTURAL
5/8" TYPE "X" GYPSUM BOARD
RESILIENT ISOLATION CLIP
(RSIC-1 OR EQUAL)
6" - 18 GA. GALVANIZED METAL FRAMING
@ 48" O.C. MIN., SEE STRUCTURAL
7/8" - 25 GA. METAL FURRING
CHANNEL @ 24" O.C.
SECURITY/STC 50 MIN.
FLOOR/CEILING ASSEMBLY
(RAL# TL01/215, STC 60)
2 1/2" GALV. METAL FRAMING
(2) LAYERS OF 5/8" TYPE "X" GYPSUM
WALL BOARD, SEAL TO DECK ABOVE
FILL CAVITY WITH BATT
INSULATION, TYP.
COMPLETELY FILL VOID BETWEEN
TOP TRACK AND DECK WITH SOUND
ATTENUATION INSULATION
BOTTOM OF STEEL
BEAM BEYOND
1/
2"
1/
4"
MEZZANINE
17'-6"
1/
4"
1/ 2"
1/
2"
1/ 4"
(2) LAYERS OF 5/8" TYPE "X" GYPSUM
WALL BOARD, SEAL TO DECK ABOVE
CONCRETE SLAB ON GALV.
METAL DECK, SEE STRUCTURAL
3 1/2" SOUND ATTENUATION INSULATION
GALV. METAL FRAMING AS SCHEDULED
SECURITY/STC 50 MIN.
WALL ASSEMBLY
STEEL BEAM, SEE STRUCTURAL
5/8" TYPE "X" GYPSUM BOARD
RESILIENT ISOLATION CLIP
(RSIC-1 OR EQUAL)
6" - 18 GA. GALVANIZED METAL FRAMING
@ 48" O.C. MIN., SEE STRUCTURAL
7/8" - 25 GA. METAL FURRING
CHANNEL @ 24" O.C.
SECURITY/STC 50 MIN.
FLOOR/CEILING ASSEMBLY
(RAL# TL01/215, STC 60)
BOTTOM OF STEEL
BEAM BEYOND
COMPLETELY FILL VOID BETWEEN
TOP TRACK AND DECK WITH SOUND
ATTENUATION INSULATION
GROUND FLOOR (LOW)
6"
A
4"
CONCRETE SLAB,
SEE STRUCTURAL
CONCRETE APRON, SEE CIVIL
STAINLESS STEEL TRANSITION
FLASHING, PAINT TO MATCH STUCCO
STUCCO WEEP SCREED
PROVIDE 8" WIDE SELF-ADHERED
MEMBRANE FLASHING 4" ONTO VERTICAL
LEG OF STAINLESS STEEL FLASHING
(2) LAYERS OF 5/8" TYPE
"X" GYPSUM WALLBOARD,
SEAL TO DECK ABOVE
R-5 RIGID INSULATION
FLUID APPLIED AIR AND
MOISTURE BARRIER
1" NOMINAL CEMENTITIOUS STUCCO
SYSTEM OVER GALV. METAL LATH
8" - 16GA GALV. METAL
STUDS, SEE STRUCTURAL
R-19 THERMAL
BATT INSULATION
3/4" - 10GA EXPANDED
METAL SECURITY MESH
(2) LAYERS OF 5/8" TYPE "X"
EXTERIOR GYPSUM SHEATHING
2"
PAINT CONCRETE TO MATCH
STUCCO COLOR
A
SHEET
IDENTIFICATION
US Army Corps of
Engineers ® Mobile District
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S
IG
N E
D B
Y
B U
L L
O C
K T
IC
E
A S
S O
C
IA
T E
S E
C
E R
V A
N T
E S
S T
R E
E T
P E
N S
A C
O L
A F
L O
R
ID
A
2 3 4 5
B
C
D
D R
A W
N B
Y
S B
M T
B Y
P L
O T
S C
A L
E
S
IZ
E
C K
D B
Y
P L
O T
D A
T E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
P R
O J
E C
T N
U M
B E
R
F
IL
E N
A M
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
:1 x
M O
B
IL
E D
IS
T
R
IC
T M
O B
IL
E
A
L A
B A
M A
O C
T
M
E F
AMENDMENT 0003
E G
L
IN
A
IR
F O
R C
E B
A S
E F
L O
R
ID
A B
U
IL
D
IN
G
L
A B
E X
P A
N S
IO
N
A-510FTFA20DR04
F L
O O
R
C E
IL
IN
G A
S S
E M
B L
Y D
E T
A
IL
S
M F
O X
C
M O
X L
E Y
B
M A
G G
IO
R
E
B T
A
O C
T O
B E
R
M E
F
A
.D W
G
1 1/2" = 1'-0"A-510
2 FLOOR SLAB DETAIL
1 1/2" = 1'-0"A-510
3 SECTION AT GUARDRAIL
SCALE: 1 1/2" = 1'-0"
0 4" 8" 1'-4"
1 1/2" = 1'-0"A-510
4 BEAM/FLOOR FURR-OUT DETAIL
1 1/2" = 1'-0"A-510
6 STC CEILING & WALL DETAIL AT BEAM
1 1/2" = 1'-0"A-510
TYPICAL STC WALL & FLOOR/CEILING
ASSEMBLY DETAIL
3" = 1'-0"A-510
1 EXTERIOR WALL AT SLAB DETAIL
SCALE: 3" = 1'-0"
0 2" 4" 8"
A
M E
N D
M E
N T
J A
N
R E
V
IS
E D
S T
C C
E
IL
IN
G
F R
A M
ROOM FINISH / COLOR SCHEDULE KEY
INTERIOR FLOOR FINISHES
EF1 EPOXY FLOORING: DURALL DURA SEAL; 400 EPOXY COATING,
2 COATS WITH WHITE ALUMINUM OXIDE - FINE ADDITIVE;
COLOR: 110-LIGHT GRAY
EF2 EPOXY FLOORING: DURALL DURA SEAL; 400 EPOXY COATING,
2 COATS WITH WHITE ALUMINUM OXIDE - MEDIUM ADDITIVE;
COLOR: 110-LIGHT GRAY
GR1 GROUT: CUSTOM BUILDING PRODUCTS; SANDED GROUT
COLOR: PEWTER 19; PROVIDE 2 COATS GROUT SEALER
PA1 PORCELAIN TILE: DALTILE; VOLUME 1.0 SERIES;
COLOR: AMPLIFY BLACK VL70; SIZE: 6" X 6"
RM2 RESILIENT MATERIAL: STATIC WORX; ECLIPSE EC RUBBER;
COLOR: PRESTO (GRAY BACKGROUND WITH SALT/PEPPER
COLORING); SIZE: 24" X 24" X 2mm
SC SEALED CONCRETE; H&C COLOR TOP SOLVENT BASED
SOLID COLOR SEALER 250 SHERWIN WILLIAMS;
COLOR: GREY SCREEN SW7071
INTERIOR BASE FINISHES
CTB1 CERAMIC TILE BASE: DALTILE; COLORWHEEL SERIES;
COLOR: SUEDE GRAY 0182, SEMI-GLOSS; SIZE: 6" X 6"
FLAT TOP COVE BASE #A-3601
GR2 GROUT: CUSTOM BUILDING PRODUCTS;
COLOR: BRIGHT WHITE 381;
PROVIDE 2 COATS GROUT SEALER
RM1 RESILIENT MATERIALS: TARKETT; TIGHTLOCK WALL BASE
4" HIGH COVE BASE; COLOR: MEDIUM GRAY 28
INTERIOR WALL FINISHES
CBB CEMENTITIOUS BACKER BOARD
CT1 CERAMIC TILE: DALTILE; COLORWHEEL SERIES;
COLOR: ARCTIC WHITE 0190, SEMI-GLOSS; SIZE 6" X 6"
INSTALLATION METHOD: STACK BOND
CT2 CERAMIC TILE: DALTILE; COLORWHEEL SERIES;
COLOR: SUEDE GRAY 0182, SEMI-GLOSS; SIZE 6" X 6"
INSTALLATION METHOD: STACK BOND
GWB GYPSUM WALL BOARD
GR2 GROUT: CUSTOM BUILDING PRODUCTS;
COLOR: BRIGHT WHITE 381; PROVIDE 2 COATS GROUT SEALER
PT1 PAINT: SHERWIN WILLIAMS; GRAY SCREEN SW7071
EGG-SHELL FINISH
INTERIOR CEILING FINISHES
ACT1 ACOUSTICAL CEILING TILE: ARMSTRONG;
OPTIMA SQUARE LAY-IN; 24"x24"x3/4"; COLOR: WHITE
GRID: 15/16" PRELUDE XL; COLOR: WHITE
EXP EXPOSED STRUCTURE, PAINTED PT3
PT3 PAINT: SHERWIN WILLIAMS: CEILING BRIGHT WHITE SW7007;
SEMI-GLOSS FINISH
PT4 PAINT: SHERWIN WILLIAMS: CEILING BRIGHT WHITE SW7007;
FLA…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .