am_06_31MAY22_Part2.pdf
PDF 20 MB Posted
- Attached to
- Construction of a Central Chilled Water Plant
- Solicitation number
- W9126G22R0043
About this file
This document provides details on a federal contract opportunity for construction services. The solicitation number is W9126G22R0043 and seeks construction of a central chilled water plant at Fort Hood, Texas. The Department of the Army Corps of Engineers Engineering District Fort Worth is the contracting agency. The solicitation was issued on November 8, 2021 and includes drawings and a justification and authorization for HVAC chillers. The opportunity type is listed as a solicitation and responses were due based on the standard FAR solicitation timeline.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| CEP_Site_Visit_Roster_02JUN22.pdf | ||
| am_08_17JUN22.pdf | ||
| am_7_08JUN22.pdf | ||
| am_06_31MAY22_Part1.pdf | ||
| am_06_31MAY22_Part3.pdf | ||
| am_06_31MAY22_Part4.pdf | ||
| am_5_12APR21.pdf | ||
| am_4_17DEC21.pdf | ||
| am_3.pdf | ||
| am_3.pdf | ||
| am_2_30NOV21.pdf | ||
| CEP Site Visit Roster.pdf | ||
| am_1.pdf | ||
| JA Replace Fuel Facilty for Monaco_22R0043_Redacted.pdf | ||
| Electrical Meters_JA_22R0043_Redacted.pdf | ||
| G22R0043_08NOV21.pdf | ||
| G22R0043_Drawings.pdf | ||
| JA_Fort Hood_HVAC Chillers_Redacted.pdf |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
R E
N O
V A
T
IO
N O
F B
U
IL
D
IN
G
Sheet of 26
DIRECTORATE OF
L H
C A
D E
N C
E
FT. HOOD, TEXAS
PUBLIC WORKS
REFERENCE
D e s ig n f il e n o
D ra w in g c o d e
M a rk
A p p r.
D a te
D e s c r ip ti o n
NUMBER
SHEET
P lo t s c a le
P lo t d a te
F il e n a m e
S u b m it te d b y
C k d b y
R ev
D a te
R e v ie w e d b y
D e s ig n e d b y
D w n b y
C A
D E
N C
E C
O N
T R
A C
T S
E R
V
IC
E S
L
L C
C
A S
S H
O W
N0
F T
H
O O
D T
E X
A S
T E
L
-9
/F
A X
(2
-9
C A
D E
N C
E C
O N
T R
A C
T S
E R
V
IC
E S
L
L C
B U
IL
D
IN
G
S
U
IT
E B
P A
J
41009597P
Bldg No.
JOC Project No.
Task Order No.
14010
W91151-06-D-0013
Contract No.
W O
R K
IN
G
D R
A W
IN
G
S F
O R
R E
D L
IN
E
A
A-TX0184-659-26
A S
B U
IL
T
S S
U B
M
IT
T E
D F
O R
A P
P R
O V
A L
B
ELECTRICAL LEGEND
C CC C
WP
SPECIAL PURPOSE OUTLET
MOTOR, HORSEPOWER, FLA, OR KW AS INDICATED
MANUAL MOTOR STARTERSm
J
REFERENCE TO SPECIAL ELECTRICAL NOTE NO. 1
101 ROOM NUMBER
EXIT SIGN, SINGLE FACE, CEILING OR WALL MOUNTED
S
S
PC
F
SD
D
SD
HEAT DETECTOR, CEILING-MOUNTED
SMOKE DETECTOR, CEILING-MOUNTED
SMOKE DETECTOR, DUCT-MOUNTED
R T
R RELAY, FAN SHUTDOWN
FACP
COMBINATION STARTER, SIZE AS NOTED
H L
TRANSFORMER, SIZE & TYPE AS NOTED
C
PANELBOARD
MANUAL PULL STATION, MOUNT AT 48" AFF
HD
STROBE LIGHT, WALL MOUNTED, 80" AFFL
MAGNETIC MOTOR STARTER, SIZE AS NOTED
HORN & LIGHT, WALL MOUNTED, 80" AFF
THE CONTRACTOR; AND AS A PART OF THIS CONTRACT, THE CONTRACTOR SHALL
PROTECTIVE DEVICE IN THE PANEL, SWITCHBOARD, ETC., EXCEPT AS OTHERWISE
ONLY THAT PORTION ASSOCIATED WITH THE DEMOLISHED DEVICE SHALL BE REMOVED
CONDITION.
TO ITS NEW LOCATION. CONDUIT SHALL BE ROUTED SO AS NOT TO INTERFERE
CONTRACTOR SHALL RELOCATE AND RECONNECT CIRCUITRY ASSOCIATED WITH THE
RELOCATION OF THE ITEM.
NEW LOCATION. PROVIDE CONNECTION OF SUCH RELOCATED ITEMS TO NEW OR
EXTENDED CIRCUITRY AS SHOWN ON THE DRAWINGS.
GENERAL DEMOLITION NOTES:
1. REMOVED ELECTRICAL EQUIPMENT AND MATERIALS SHALL BECOME THE PROPERTY OF
2. EACH ITEM OF EQUIPMENT, RECEPTACLES, LIGHT FIXTURES, MOTORS, ETC., SHOWN
D. WHERE SUCH INACCESSIBLE CONDUIT ENDS OR MUST BE TERMINATED IN
3. WHERE ONLY A PORTION OF A CIRCUIT’S LOAD IS SCHEDULED TO BE REMOVED,
4. WHERE EXTENSION OF AN EXISTING CIRCUIT IS REQUIRED, CONDUIT AND WIRE
5. WHERE AN ITEM OF EQUIPMENT IS SCHEDULED TO BE REMOVED AND RELOCATED, ITS
PHOTOELECTRIC CELL, MAST MOUNTED
REMOVE EQUIPMENT AND MATERIAL OFF THE PROPERTY.
WITH THE USE OR MAR THE AESTHETICS OF THE AREA. WHERE NECESSARY, THE
ALONG WITH ITS ASSOCIATED SWITCHGEAR AND DEVICES, ETC., AND RELOCATED TO THE
ELECTRICAL ABBREVIATIONS
SHALL BE RUN (CONCEALED WHERE POSSIBLE) FROM THE ITEM’S EXISTING LOCATION
AL2-12
F
Q
Z
3J
CONCEALED CONDUIT WITH ONE PHASE CONDUCTOR AND
ONE NEUTRAL CONDUCTOR AND A SEPARATE GROUND
CONDUCTOR (GREEN WIRE)
DISCONNECT SWITCH (NON-FUSED, UNLESS
OTHERWISE NOTED), SIZE AS NOTED
WALL-MOUNTED FIXTURE; LETTER DENOTES TYPE IN
FIXTURE SCHEDULE
COMPUTER OUTLET, MOUNT AT 18" AFF UNLESS
OTHERWISE NOTED
EXIT SIGN, DOUBLE FACE, WITH DIRECTIONAL ARROWS,
CEILING-MOUNTED
WALL SWITCH, SINGLE POLE, 20A, 120/277 VOLT;
WP= WEATHERPROOF, MOUNT AT 48" AFF
REMOTE TEST SWITCH FOR DUCT SMOKE DETECTOR
CONDUIT WITH HOMERUN ARROW TO BREAKER NO. 12
IN PANEL "AL2"
DUPLEX RECEPTACLE, WEATHERPROOF,
MOUNT 24" ABOVE FINISHED FLOOR
FLUORESCENT FIXTURE; LETTER DENOTES TYPE IN
FIXTURE SCHEDULE
INCANDESCENT OR HID FIXTURE, CEILING-MOUNTED;
LETTER DENOTES TYPE IN FIXTURE SCHEDULE
WALL SWITCH, 3-WAY; 4= 4-WAY; 2= DOUBLE-POLE;
P= PILOT LIGHTED HANDLE, MOUNT AT 48" AFF
FIRE ALARM CONTROL PANEL, SEMI-RECESSED IN
WALL, WITH TOP AT 5’-10" AFF
C. WHERE CONDUIT IS ASSOCIATED WITH AN ITEM SHOWN TO BE REMOVED AND
TO A POINT WHERE THE REMAINING LOAD IS ACTIVE AND IN GOOD OPERATING
ASSOCIATED CIRCUITRY SHALL ALSO BE REMOVED IN ACCORDANCE WITH NOTE 2 ABOVE,
MENTIONED IN NOTES 3 AND 4 BELOW.
DUPLEX RECEPTACLE, 20A, 125V, GROUNDED-TYPE,
MOUNT 18" ABOVE FINISHED FLOOR UNLESS OTHERWISE NOTED.
IG = ISOLATED GROUND TYPE
GFI = GROUND FAULT INTERRUPTER TYPE
EXISTING INCANDESCENT LIGHT TO BE REMOVED
EXISTING 3-WAY WALL SWITCH TO BE REMOVED
EXISTING WALL SWITCH TO BE REMOVED
EXISTING EXIT LIGHT TO BE REMOVED
EXISTING 1’x 4’ FLUORESCENT FIXTURE TO BE REMOVED
EXISTING 2’x 4’ FLUORESCENT FIXTURE TO BE REMOVED
EXISTING JUNCTION BOX TO BE REMOVED
EXISTING TELEPHONE OUTLET TO BE REMOVED
EXISTING SPECIAL PURPOSE OUTLET TO BE REMOVED
EXISTING DUPLEX RECEPTACLE TO BE REMOVED
ACCESS CONTROL PANEL
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AIR HANDLING UNIT
AMPERE
APPROXIMATE
ARCHITECTURAL
AUTOMATIC
AMERICAN WIRE GAUGE
AUTOMATIC TRANSFER SWITCH
ALUMINUM
ACP
AFF
AFG
AHU
AMP, A
APPROX
ARCH
AUTO
AWG
ATS
ALUM
BELOW FINISHED GRADE
BUILDING
BFG
BLDG
CONDUIT
CABINET
CIRCUIT BREAKER
CLOSE CIRCUIT TELEVISION
CHILLED WATER PUMP
CIRCUIT
CEILING
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
COPPER
C
CAB
CB
CCTV
CHP
CKT
CLG
CMU
COL
CONC
CU
DETAIL
DIAMETER
DIMENSION
DISCONNECT
DOWN
DRAWINGS
DET
DIA
DIM
DISC
DN
DWGS
FIRE ALARM CONTROL PANEL
FAN COIL UNIT
FLOOR
FULL LOAD AMPERES
FLEXIBLE
FLUORESCENT
FOOT: FEET
FACP
FCU
FL, FLR
FLA
FLEX
FLUOR
FT
GAUGE
GALVANIZED
GROUND FAULT INTERRUPTER
GROUND
GA
GALV
GFI
GRND
HANDICAPPED
HIGH INTENSITY DISCHARGE
HAND OFF AUTOMATIC SWITCH
HORSEPOWER
HIGH PRESSURE SODIUM
HEIGHT
HEATER
HOT WATER
HOT WATER PUMP
HC
HID
HOA
HP
HPS
HT
HTR
HW
HWP
IN ACCORDANCE WITH
ISOLATED GROUND
INCANDESCENT
JUNCTION BOX
THOUSAND CIRCULAR MILS
KILOVOLT
KILOVOLT AMPERES
KILOWATT
KILOWATT HOUR
IAW
IG
INCAND
J-BOX
kcmil kV kVA kW kWH
LIGHT EMITTING DIODE
LINEAL FOOT
LOW VOLTAGE
MAXIMUM
MAIN CIRCUIT BREAKER
MOTOR CONTROL CENTER
THOUSAND CIRCULAR MILS
MANUFACTURER
METAL HALIDE
MINIMUM
MAIN LUGS ONLY
MOUNTING
METER
MILLIMETER
LED
LF
LV
MAX
MCB
MCC
MCM
MFR
MH
MIN
MLO
MTG
m mm
NORMALLY CLOSED
NATIONAL ELECTRICAL CODE
NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION
NON-FUSED
NORMALLY OPEN
NOMINAL
NOT TO SCALE
NOT IN CONTRACT
ON CENTER
OPPOSITE HAND OR OVERHEAD
OPPOSITE
POLE
PUSHBUTTON
POWER FACTOR
PHASE
PANEL
PRIMARY
POLYVINYL CHLORIDE
NC
NEC
NEMA
NF
NO
NOM
NTS
NIC
OC
OH
OPP
P
PB
PF
PH, 0
PNL
PRIM
PVC
ELECTRICAL GENERAL NOTES
EACH
EXHAUST FAN
ELECTRICAL
ELEVATION: ELEVATOR
ENCLOSURE
EXPLOSIVE PROOF
EQUAL
EQUIPMENT
ELECTRICAL WATER COOLER
EXHAUST
EXTERIOR
EA
EF
ELEC
ELEV, EL
ENCL
EP
EQ
EQUIP
EWC
EXH
EXT
A. ASSOCIATED CIRCUITRY SHALL BE DEFINED TO INCLUDE ALL CONDUIT,
CONDUCTORS, BOXES, WIRING DEVICES, COVERPLATES, LAMPS, FIXTURES,
WIREWAYS, SWITCHES, STARTERS, ETC., THAT ARE ASSOCIATED WITH THE
ITEM SHOWN TO BE REMOVED.
B. THE PROTECTIVE DEVICE SHALL REMAIN AS AN INTEGRAL PART OF THE
EXISTING PANEL, SWITCHBOARD, ETC., AND SHALL BE LABELED AS A SPARE
OR BE USED FOR NEW CIRCUITRY AS SHOWN.
1. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CONFIRM COMPATIBILITY BETWEEN
CEILING TYPE, AS DEFINED ON THE ARCHITECTURAL ROOM FINISH SCHEDULE AND LIGHT FIXTURE
TRIM AS DEFINED ON THE FIXTURE SCHEDULE. HOWEVER, NO CHANGE OR DEVIATION SHALL BE
MADE FROM THE CONTRACT DOCUMENTS WITHOUT PRIOR APPROVAL.
2. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE TO THE PROPER SIDE OF
THE DOOR ANY SWITCH, RECEPTACLE OR DEVICE BEING AFFECTED BY ANY CHANGE IN DIRECTION
OF DOOR SWINGS AS SHOWN ON THE ARCHITECTURAL FLOOR PLANS.
3. LIGHTING IN MECHANICAL ROOMS SHALL BE ADJUSTED IN FIELD FOLLOWING INSTALLATION OF
MECHANICAL AND ELECTRICAL EQUIPMENT TO PROVIDE RELATIVELY UNIFORM LIGHTING AS
GENERALLY OUTLINED ON THE DRAWINGS.
4. REMOTE MOUNTED MOTORS SHALL BE PROVIDED WITH RECEPTACLE AND PLUG OR DISCONNECT
SWITCH TO BE COMPATIBLE WITH TYPE CONSTRUCTION AND N.E.C.
5. EACH MOTOR BEING INSTALLED ON THIS CONTRACT SHALL BE PROVIDED WITH THERMAL OVERLOAD
PROTECTION IN EITHER A MANUAL OR MAGNETIC STARTER. THERMAL ELEMENTS SHALL BE SIZED
AND INSTALLED ACCORDING TO THE FLA OF EACH MOTOR.
6. KILOWATT (kW) RATINGS FOR EQUIPMENT MOTOR LOADS OF 4kW AND LARGER ARE AS DESIGNED
WITH 95% POWER FACTOR RATING ASSUMED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
INCREASING FOR LOADS 4kW AND LARGER, AS REQUIRED OF ALL FEEDERS AND PROTECTIVE
DEVICES SERVING ANY ITEM OF EQUIPMENT SUPPLIED WITH POWER FACTOR RATINGS LESS THAN 95%.
7. IN ALL AREAS THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION BETWEEN THE
ELECTRICAL AND MECHANICAL TRADES TO PROVIDE CLEARANCES ABOVE CEILING BETWEEN RECESSED
LIGHT FIXTURES AND THERMAL INSULATION IN ACCORDANCE WITH N.E.C. PARAGRAPH 410-66.
8. THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF LIGHT FIXTURES WITH
REFLECTED CEILING PLANS FOR EXACT LOCATION OF FIXTURES. IT SHALL ALSO BE THE
CONTRACTOR’S RESPONSIBILITY TO COORDINATE WITH THE MECHANICAL CONTRACTOR AND OTHER
TRADES TO ENSURE THE PROPER INSTALLATION OF LIGHT FIXTURES, AIR DIFFUSERS, FIRE ALARM
DEVICES AND OTHER ITEMS SHOWN ON THE PLANS TO BE INSTALLED IN OR ON THE CEILING.
9. EQUIPMENT SIZES ARE AS DESIGNED. CIRCUIT BREAKERS, CONDUIT, MOTOR STARTERS,
DISCONNECT SWITCHES AND CONDUCTOR SIZES, ETC. SHALL BE ADJUSTED TO THE
EQUIPMENT SUBMITTED AND APPROVED FOR INSTALLATION ON THIS PROJECT.
THIS SHALL INCLUDE THE FOLLOWING:
A. MECHANICAL SYSTEM EQUIPMENT (INCLUDES PLUMBING SYSTEM)
B. AUTOMATIC FIRE ALARM SYSTEM EQUIPMENT
TO BE DEMOLISHED SHALL HAVE ITS ASSOCIATED CIRCUITRY REMOVED BACK TO THE
RECEPTACLE
ROOM
RAPID START
RETURN AIR
SECONDARY
SHEET
SOLID NEUTRAL
STANDARD
STEEL
SWITCH
SYSTEM
SUPPLY AIR
SWITCHBOARD
TELEPHONE
THICK
TELEPHONE TERMINAL BOARD
TYPICAL
UNDERGROUND
UNIT HEATER
UNDERWRITERS LABORATORY
UNINTERRUPTABLE POWER
SUPPLY
VOLTS
VOLT-AMPERE
WATTS: WIDE: OR WIRE
WEATHER PROOF
PHASE
SINGLE PHASE
THREE PHASE
REC
RM
RS
R/A
SEC
SHT
SN
STD
STL
SW
SYS
S/A
SWBD
TEL
THK
TTB
TYP
UG
UH
UL
UPS
V
VA
W
WP
1 0
3 0
IS IN AN INACCESSIBLE AREA SUCH AS ENCASED IN CONCRETE, ONLY THAT
INACCESSIBLE CONDUIT SHALL BE ABANDONED IN PLACE. ALL CONDUCTORS
SHALL BE REMOVED, THEN CONDUIT SHALL BE SEALED, CAPPED
OR OTHERWISE TERMINATED IN A SAFE MANNER ACCEPTABLE TO THE
CONSTRUCTION MANAGER OR AS OTHERWISE STATED IN ITEM 2D BELOW.
FINISHED SPACE, THE CONDUIT OR J-BOX SHALL BE REMOVED TO BELOW THE
FINISHED SURFACE OF WALL, CEILING OR FLOOR. THEN VOID SHALL BE
FILLED WITH NON-SHRINKING GROUT, RESURFACED, AND REFINISHED TO
MATCH SURROUNDING SURFACES.
MOTOR SENSOR WITH "ON", "OFF" CONTROL
FLUORESCENT FIXTURE WITH BUILT-IN BATTERY
PC
MOTION SENSOR (LIGHTING)
COMMUNICATION DUAL R.J.-45 OUTLET, 18" AFF, UNLESS
OTHERWISE NOTED
JUNCTION BOX (FLUSH-MOUNTED UNLESS OTHERWISE
NOTED), WITH COVER
D
PC
DIMING BALLAST CONTROL SWITCH
COMBINATION ELECTRICAL/COMMUNICATION POST WITH 2
DUPLEX RECEPTACLES AND 2 DUAL COMMUNICATION
OUTLET FOR MODULAR FURNITURE
E-001
E L
E C
T R
IC
A
L L
E G
E N
D
N O
T E
S A
N D
A B
B R
E V
IA
T
IO
N
S
B U
IL
D
IN
G
M-001
PC PUMPED CONDENSATE
FT HD FEET HEAD
dB DECIBELS
BALANCING VALVE - PLUMBING
BALANCING VALVE - MECHANICAL
DDC DIRECT DIGITAL CONTROL
SOUND ATTENUATORSA
INCHES OF WATER GAGEIN. W.G.
SUPPLY REGISTERSG
RF RETURN, TRANSFER GRILLE
LINEAR SLOT SUPPLY DIFFUSERLS
HWCP HEATING WATER CIRCULATION PUMP
STEAM HUMIDIFICATION UNITHUM
EG EXHAUST, TRANSFER, RETURN GRILLE
BIO-SAFETY DAMPERBSD
HIGH PRESSURE STEAM SUPPLYHPS
HPR
GF GLYCOL FEEDER DOSING PUMP
FAN COIL UNITFCU
AV AIR CONTROL VALVE
TSP TOTAL STATIC PRESSURE
LEAVING WATER TEMPERATURELWT
LEAVING AIR TEMPERATURELAT
ENTERING WATER TEMPERATUREEWT
ABBREVIATIONS LEGEND
GATE VALVE
RS REFRIGERANT SUCTION
RL REFRIGERANT LIQUID
MAX MAXIMUM
FAN TERMINAL UNITFTU
AS AIR SEPARATOR
PH PHASE
KW KILOWATT
PASCALSPa
CHILLED WATER PUMPCHWP
HWP HEATING WATER PUMP
RELIEF HOODRH
AIR COMPRESSORAC
SUPPLY FANSF
HX HEAT EXCHANGER
RETURN AIR FANRF
SOLENOID VALVE
GAS VALVE
POTABLE HOT WATER CIRCULATING
POTABLE HOT WATER (110 DEG F)
POTABLE COLD WATER
VARIABLE FREQUENCY DRIVEVFD
PRE FILTERPF
BSC BIOSAFETY CABINET
HUMIDIFIERHUM
COLD WATERCW
HEATING COILHC
CHILLED WATER RETURN
CHILLED WATER SUPPLY
HEATING WATER SUPPLY
HEATING WATER RETURN
HVAC PIPING
HWS
HWR
CWR
CWS
PLUMBING PIPING
LEAVING
LRA
LWB
LVG
LDB
LOCKED ROTOR AMPS
LEAVING WET BULB TEMPERATURE
LEAVING DRY BULB TEMPERATURE
BALL VALVE
BUTTERFLY VALVE
SWING GATE CHECK VALVE
VALVES
MINIMUM
MBH
MIN
NC
NO
OA
PRV
PSIG
PSI
PD
NORMALLY OPEN
THOUSAND BTU PER HOUR
POUNDS PER SQUARE INCH
PRESSURE REDUCING VALVE
PSI GAUGE
OUTSIDE AIR
PRESSURE DROP
NORMALLY CLOSED
RA
RH
RLA
SA
S.P.
TEMP
TDH
RPM
RUNNING LOAD AMPS
REVOLUTIONS PER MINUTE
STATIC PRESSURE
SUPPLY AIR
TOTAL DYNAMIC HEAD
RETURN AIR
RELATIVE HUMIDITY
TEMPERATURE
BHP
AMPS
BRAKE HORSEPOWER
MECHANICAL ABBREVIATIONS
AMPERES
CFM
CWS
CWR
BTU
BTUH
BDD
DB
EAT
COND
ENTERING AIR TEMPERATURE
DRY BULB
CUBIC FEET PER MINUTE
CHILLED WATER SUPPLY
CHILLED WATER RETURN
CONDENSATE
BTU PER HOUR
BACK DRAFT DAMPER
BRITISH THERMAL UNIT
%%dF
ESP
ENT
EWB
FLA
ENTERING WET BULB TEMPERATURE
FULL LOAD AMPS
DEGREES FAHRENHEIT
EXTERNAL STATIC PRESSURE
ENTERING
ENTERING DRY BULB TEMPERATUREEDB
GLOBE VALVE
CAP OR PLUG
ELBOW, TURNED DOWN
ELBOW, TURNED UP
FLANGED CONNECTION
TEE, OUTLET UP
TEE, OUTLET DOWN
PIPE UNION
FITTINGS
VOLTS
TYPICALTYP
VD
V
WB
WG
WC
WATER GAUGE
WATER COLUMN
VOLUME DAMPER
WET BULB
LOUVER
PUMP
REFRIGERATED AIR DRYER
INVERTED BUCKET TRAP
DIRECTION OF FLOW
STEAM TRAP
EXPANSION TANK
SUPPLY DIFFUSER
GAUGE
FEET
GA
FT
GC
FPM
GPM
HERTZ
HP
HZ
HORIZ
GENERAL CONTRACTOR
FEET PER MINUTE
GALLONS PER MINUTE
HORSEPOWER
HORIZONTAL
L
RAD
P
IB
CC
FD
EF
F & T
AHU
FIRE DAMPER
FLOAT & THERMOSTATIC
EXHAUST FAN
AIR HANDLING UNIT
COOLING COIL
EQUIPMENT ABBREVIATIONS
ST
ET
HC
HUH HYDRONIC UNIT HEATER
HYDRONIC HEATING COIL
SD
ELECTRIC OPERATED GATE VALVE
3WAY ELECMOTOR CONTROLLER
M
M
S
CW DOMESTIC COLD WATER
DOMESTIC HOT WATER GENERATOR
DOMESTIC HOT WATER, CIRCULATING
REDUCED PRESSURE BACKFLOW PREVENTER
DOMESTIC HOT WATER
STANDARDSTD
SANITARY
RPBFP
SAN
HARD COLD WATER
INVERT ELEVATION
HDCW
HWC
INV. EL.
HW
DOWN
FLOOR CLEANOUT
FLOOR DRAIN
DN
FD
DHWG
FCO
PLUMBING ABBREVIATIONS
CIRCULATINGCIRC
BASEBOARD HYDRONIC HEATERBBH
CRU CONDENSATE RECOVERY UNIT
CRAC COMPUTER ROOM AIR CONDITION
EAU EXHAUST AIR UNIT
SAV SUPPLY AIR VALVE
EAV EXHAUST AIR VALVE
SHF SUPPLY AIR HEPA FILTER
EXHAUST AIR HEPA FILTEREHF
PHF PLUMBING HEPA FILTER
IF INTERMEDIATE FILTER
PHC HYDRONIC PREHEAT COIL
EBSD EXHAUST AIR BIO-SAFETY DAMPER
SBSD SUPPLY AIR BIO-SAFETY DAMPER
HRCP HEAT RECOVERY PUMP
CLEAN OUTCO
CONDENSATE RETURN PUMPCRP
HOSE BIBHB
SHOWER DRAINSHD
SEWAGE EJECTORSE
SUMP PUMPSP
DOMESTIC HOT WATER CIRCULATORDHWCP
MEDIUM PRESSURE STEAM SUPPLYMPS
LOW PRESSURE STEAM SUPPLYLPS
HEAT RECOVERY SUPPLY
HEAT RECOVERY RETURN
HRS
HRR
CONDENSATE VENTCV
BALL VALVE
CA COMPRESSED AIR
SHOP AIRSA
SOA STATIC OUTSIDE AIR
HIGH PRESSURE STEAM CONDENSATE
MEDIUM PRESSURE STEAM CONDENSATEMPR
LOW PRESSURE STEAM CONDENSATELPR
CA
SBIO
CO2
NPCW
PHW
PCW
PHWR
NON POTABLE HOT WATER CIRCULATING
NON POTABLE HOT WATER (110 DEG F)
NON POTABLE COLD WATER
SANITARY WASTE - BIOHAZARD
LABORATORY COMPRESSED AIR
CARBON DIOXIDE GAS
VENT - NON BIOHAZARD
SANITARY WASTE - NON BIOHAZARD
VENT - BIOHAZARDVBIO
SAN
VENT
SPRING CHECK VALVES
SOLENOID OPERATED GATE VALVE
S
PNEUMATIC OPERATED GATE VALVE
M
NPHW
NPHWR
BACKFLOW PREVENTION
DOUBLE CHECK VALVE ASSEMBLY
DOUBLE CHECK VALVE ASSEMBLY
WITH OSY GATE VALVES
REDUCED PRESSURE ZONE ASSEMBLY
WITH AIR GAP AND DRAIN
OPEN STEM AND YOKEOSY
FIRST DIMENSION IS
INSIDE DUCT DIMENSION
AIR QUANTITY (CFM)
DIFFUSER SCHEDULE
TYPE REFER TO
DIFFUSER ROUND
TO MATCH DIFFUSER
CONICAL SPIN-IN FITTING
CEILING SUPPLY DIFFUSER
12x12
THE SIDE SHOWN
NECK SIZE
TO MATCH DIFFUSER
26GA SPIRAL DUCT
DIFFUSER DESIGNATION
NECK SIZE
12-A
NECK SIZE
DIMENSION
ROUND DUCT
STANDARD 24GA
FURNACE ELBOW
RETURN PANEL
TYPE B CEILING GRILLES, REGISTERS AND
COORDINATE THE LOCATION OF
DIFFUSERS WITH THE REFLECTED
CEILING PLAN
DIRECTION OF FLOW
PENETRATING FLOOR OR ROOF
NEGATIVE PRESSURE DUCT
PENETRATING FLOOR OR ROOF
POSITIVE PRESSURE DUCT
FIRE-SMOKE DAMPER
MANUAL VOLUME DAMPER
CONICAL SPIN-IN FITTING
FIRE DAMPER
FLEXIBLE DUCTWORK
MITERED ELBOW WITH TURNING VANES
NEGATIVE PRESSURE AIR DUCT UP
POSITIVE PRESSURE DUCT UP
NEGATIVE PRESSURE DUCT DOWN
POSITIVE PRESSURE DUCT DOWN
FLEXIBLE DUCT CONNECTION
RADIUS ELBOW
M
MOTORIZED DAMPER
WITH VOLUME DAMPER
FS
DUCTWORK SYMBOLS
H V
A C
A B
B R
E V
IA
T
IO
N
S A
N D
L E
G E
N D
C o n t r N o
A
B
C
D
1 2 3 4 5
F
IL
E
D A
T E
T
IM
E
D E
S
IG
N F
IL
E
D a t e reference number:
D e s c r i p t i o n D a te
A p p r
M a r k
14024
Sheet
Bldg Nos.
Project No.
DMI No.
W
C
B U
I L
D I N
G
D
IR
E C
T O
R A
T E
O F
P U
B L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G P
L A
N S
A N
D S
E R
V
IC
E S
A
U G
F Y
F
L A
G S
H
IP
P R
O J E
C T
Sheet of 45
D ir ec t or ate of Public
W o rk s
E n g in eering & Servic es D ivi s io n
R E
V
IS
E D
R E
C O
R D
D R
A W
IN
G
C n t r N o
A
B
C
D
1 2 3 4 5
F
IL
E
D A
T E
T
IM
E
D E
S
IG
N F
IL
E
D a t e reference number:
D e s c r i p t i o n D a te
A p p r
M a r k
14024
Sheet
Bldg Nos.
Project No.
DMI No.
W
C
B U
I L
D I N
G
D
IR
E C
T O
R A
T E
O F
P U
B L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G P
L A
N S
A N
D S
E R
V
IC
E S
A
U G
F Y
F
L A
G S
H
IP
P R
O J E
C T
Sheet of 45
D ir ec t or ate of Public
W o rk s
E n g in eering & Servic es D ivi s io n
R E
V
IS
E D
R E
C O
R D
D R
A W
IN
G
S
HVAC DEMOLITION PLAN
BUILDING 14024
SCALE: 1/8" = 1’-0"
8’ 4’ O 8’
N
PLAN NORTH
ROOM
MECHANICAL
1 2 3 4 5 6 7
A
B
C
D
MD101
B U
IL
D
IN
G
M
C H
A N
IC
A
L D
E M
O L
IT
IO
N P
L A
N
1 REMOVE AND DISPOSE OF AIR HANDLING UNIT AND DUCTWORK.
2 REMOVE AND DISPOSE OF HEATING WATER AND
CHILLED WATER PUMPS
3 REMOVE AND DISPOSE OF BOILER AND FLUE
4 REMOVE AND DISPOSE OF ROOF EXHAUST FAN
AND DUCTWORK
5 REMOVE AND DISPOSE OF CHILLER
GENERAL DEMOLITION NOTES
1. REMOVE AND DISPOSE OF ALL MAIN SUPPLY AIR,
RETURN AIR, AND OUTSIDE AIR DUCTWORK ASSOCIATED
WITH THE MULTIZONE AIR HANDLER.
2. REMOVE AND DISPOSE OF ALL BRANCH DUCTS
AND SUPPLY DIFUSERS.
3. REMOVE AND DISPOSE OF ALL ZONE THERMOSTATS
4. REMOVE AND DISPOSE OF ALL RETURN AND EXHAUST
GRILLES AND REGISTERS.
4. REMOVE AND DISPOSE OF ALL HEATING WATER AND
CHILLED WATER PIPING.
5. DRAWINGS OF THE EXISTING HVAC SYSTEM ARE AVAILABLE.
KEY NOTES
6 CAP EXISTING OIL PIPING
7 REMOVE GAS LINE
n t r N o
A
B
C
D
1 2 3 4 5
F
IL
E
D A
T E
T
IM
E
D E
S
IG
N F
IL
E
D a t e reference number:
D e s c r i p t i o n D a te
A p p r
M a r k
14024
Sheet
Bldg Nos.
Project No.
DMI No.
W
C
B U
I L
D I N
G
D
IR
E C
T O
R A
T E
O F
P U
B L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G P
L A
N S
A N
D S
E R
V
IC
E S
A
U G
F Y
F
L A
G S
H
IP
P R
O J E
C T
Sheet of 45
D ir ec t or ate of Public
W o rk s
E n g in eering & Servic es D ivi s io n
R E
V
IS
E D
R E
C O
R D
D R
A W
IN
G
S
M-101
B U
IL
D
IN
G
H
A C
P L
A N
-W E
S T
HVAC PLAN - WEST
R E
F E
R T
O S
H E
E T
M
F O
C H
A N
IC
A
L R
O O
M P
L A
N
N
PLAN NORTH
SCALE: 1/4" = 1’-0"
4’ 2’ O 4’
XXX SUPPLY CFM
XXX EXHAUST CFM
10"x10" OPEN END ABOVE CEILING.
CONDENSING UNIT LOCATED ON ROOF.
GENERAL NOTES
1. BRANCH HW PIPING TO REHEAT COILS SHALL BE
SIZED 1/2" FOR FLOW RATES FROM 0-1 GPM AND
3/4" FOR FLOW RATES FROM 1.1-2.6GPM.
KEYED NOTES
PROVIDE ROOF PLATFORM.
CORRIDOR
OPEN AREA
JAN.
SHWR
OFFICE
CLASSROOM
CORRIDOR
CLERKS
ROOM
CONFERENCE
TOILET
COMMAND
X.O.
C.O.
C.S.M.
S-1
STORAGE
RECEPTION
WORKROOM
NCO
CSM
NCO
XO
NCO
CO
STORAGE
OFFICE
OFFICE
STORAGE
SIPR
NCO
S-1
215 215
VAV-4 VAV-5
VAV-2
14%%c8%%c
10%%c 14%%c
8% %c
8% %c
8% %c c c
6%%c
10%%c
10%%c
6%%c
6%%c c10 c
10%%c
14%%c
8%%c
8%%c
6%%c
8%%c 10%%c 12%%c
EF-2
EF-1
10-A
6-A
8-a
10-a
8-a
12-a 6-a 6-A
8-A
6-A
8%%c
10-A
8-A
8-A
8-A 10-A 8-A
8-a 8-a
8-a 8-a
10-A
10-A 10-A10-A
8-A
8-A 8-A
8-A 8-A
8-A
8-A
8-a8-a
EVAP-1
CU-1
H
W S
H
W R
1/2"
2" HWR
1 1/4" HWS
T
T
T
T
T
T
T
T
T
M A
T C
H L
IN
E
S E
E S
H E
T
-1
F
N T
IN
U
A T
IO
N
A
T C
H L
IN
E
S E
E S
H E
F
N T
IN
U
A T
8x8-D
2"2"
VAV-1
VAV-16
VAV-6
VAV-3
VAV-8
2325 2294
1961 2171
11711
1915 2123
2106 2024 11210
21232202
4 5
1784 1823
185 185 n t r N o
A
B
C
D
1 2 3 4 5
F
IL
E
D A
T E
T
IM
E
D E
S
IG
N F
IL
E
D a t e reference number:
D e s c r i p t i o n D a te
A p p r
M a r k
14024
Sheet
Bldg Nos.
Project No.
DMI No.
W
C
B U
I L
D I N
G
D
IR
E C
T O
R A
T E
O F
P U
B L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G P
L A
N S
A N
D S
E R
V
IC
E S
A
U G
F Y
F
L A
G S
H
IP
P R
O J E
C T
Sheet of 45
D ir ec t or ate of Public
W o rk s
E n g in eering & Servic es D ivi s io n
R E
V
IS
E D
R E
C O
R D
D R
A W
IN
G
S
M-102
B U
IL
D
IN
G
H
A C
P L
A N
E
A S
T
REFER TO SHEET M-401 FOR
MECHANICAL ROOM PLAN
HVAC PLAN - EAST
N
PLAN NORTH
SCALE: 1/4" = 1’-0"
4’ 2’ O 4’
IT
E M
S R
E M
O V
E D
-1
-0
M
A L
RETURN AIR FLOW
THROUGH CMU WALL
RETURN AIR FLOW
THROUGH CMU WALL
xxx SUPPLY CFM xxx EXHAUST CFM
10"x10" OPEN END ABOVE CEILING.
CONDENSING UNIT LOCATED ON ROOF.
GENERAL NOTES
1. BRANCH HW PIPING TO REHEAT COILS SHALL BE
SIZED 1/2" FOR FLOW RATES FROM 0-1 GPM AND
3/4" FOR FLOW RATES FROM 1.1-2.6GPM.
KEYED NOTES
PROVIDE ROOF PLATFORM.
LOBBY
TOILET
TOILET
RECEPTION/
MECHANICAL ROOM
MENS
WOMENS
JAN.
SHWR
ROOM
STORAGE
NCO
S-2134
S-2
S-3
NCO
S-4
S-4
NCO
S-3
OFFICE
STORAGE
GEN.
VAULT
SIPR
BREAK
SHWR
CORRIDOR
CLERKS
CORRIDOR
NIPR
10%%c
220 220
VAV-12
44x22
24x20
8%%c
8%%c
12%%c 12x12
14%%c c
8%%c
14%%c
8% %c
VAV-7
14%%c
14%%c
6% %c
6% %c
12%%c 14%%c c
8%%c
6%%c
6%%c
8%%c
8%%c
8%%c
8% %c
6%%c
6%%c
AHU-1
EF-3
EF-2
EF-4
RA DUCT
OPENING
8-a
6-A
8-a
8-a
8-a 8-a 8-a
8-a
8-a
8-a 8-a
8-A
8-A
8-A
8-A
8-A8-A
8-A
8-A
6-A
6-A
10-a 10-a
10-a
10-a
10-a 10-a
8-A
8-A
8-c
8-c
H W
SHWR
2" HWR
1 1/2"HWS
H W
R
EVAP-1
EVAP-2
CU-1
2"
2"
1 1/4" HWS
T
T
T T
T
T
T
T
T
3"3"
8"
8"
T
1/2"
COND
CU-2
BOILER
UH-1
M A
T C
H L
IN
E
S E
E S
H E
F
N T
IN
U
A T
A
T C
H L
IN
E
S E
E S
H E
F
N T
IN
U
A T
28x20
HWP-1
HWP-2
ET-1
ET-2
SF-1
8x8-D
8x8-D
1"
1"
2" x
44x22
2"
VAV-9
VAV-10
VAV-14 VAV-17
VAV-13
VAV-15VAV-11
VAV-8
1332 1311 1571
2375 2326
24122261
13121461
140 120
160120140 n t r N o
A
B
C
D
1 2 3 4 5
F
IL
E
D A
T E
T
IM
E
D E
S
IG
N F
IL
E
D a t e reference number:
D e s c r i p t i o n D a te
A p p r
M a r k
14024
Sheet
Bldg Nos.
Project No.
DMI No.
W
C
B U
I L
D I N
G
D
IR
E C
T O
R A
T E
O F
P U
B L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G P
L A
N S
A N
D S
E R
V
IC
E S
A
U G
F Y
F
L A
G S
H
IP
P R
O J E
C T
Sheet of 45
D ir ec t or ate of Public
W o rk s
E n g in eering & Servic es D ivi s io n
R E
V
IS
E D
R E
C O
R D
D R
A W
IN
G
S
M-401
B U
IL
D
IN
G
C H
A N
IC
A
L R
O O
M P
L A
N A
N D
S E
C T
IO
N
S
MECHANICAL ROOM PLAN
BUILDING 14024
MECHANICAL ROOM SECTION
BUILDING 14024
N
PLAN NORTH
SCALE: 1/4" = 1’-0"
4’ 2’ O 4’
SCALE: 1/4" = 1’-0"
4’ 2’ O 4’
REFER TO DETAILS
SHEETS M-501
AND M-502
1-1/4" GAS
LINE
ENTER BUILDING
AT APPROX 48"
ABOVE FLOOR
VENT WH THRU
ROOF
4 5 64 5 6
44x22
14%%c
AHU-1
CH-1
RA DUCT
OPENING
6-A 8-c
H W
SHWR
C W
S
C W
R
H W
R
2"
3"3"
8"
8"
BOILER
UH-1
28x20
HWP-1
HWP-2
ET-1
ET-2
BURIED
SF-1
8x8-D
8x8-D
1"
1"
2" x
44x22
2"
FIRE DAMPERS
22x44
20x28
22x46
AHU-1
AIR FLOW
MEASURING
STATION5
EXISTING 84x24 OUTSIDE AIR INTAKE.
PROVIDE SIDEWALL SUPPLY FAN. MOUNT AT LOCATION
OF EXISTING MECHANICAL ROOM SUPPLY FAN.
EXISTING 30"x30" RELIEF AIR DUCT UP THROUGH ROOF.
KEYED NOTES
4 EXISTING 18"X18" DUCT WITH GRAVITY DAMPERS AND GRAVITY
VENTILATOR UP THROUGH CEILING AND ROOF. BOILER ROOM
VENTILATION RELIEF.
5 PROVIDE TRAPPED CONDENSATE DRAIN LINE FROM AHU
TO EXISTING FLOOR DRAIN.
6 REFER TO SHEET M-501 FOR BOILER VENTING
REQUIREMENTS.
7 NEW CHILLER
IL
D
IN
G
M-501
H V
A C
D E
T A
IL
S
C o n t r N o
A
B
C
D
1 2 3 4 5
F
IL
E
D A
T E
T
IM
E
D E
S
IG
N F
IL
E
D a t e reference number:
D e s c r i p t i o n D a te
A p p r
M a r k
14024
Sheet
Bldg Nos.
Project No.
DMI No.
W
C
B U
I L
D I N
G
D
IR
E C
T O
R A
T E
O F
P U
B L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G P
L A
N S
A N
D S
E R
V
IC
E S
A
U G
F Y
F
L A
G S
H
IP
P R
O J E
C T
Sheet of 45
D ir ec t or ate of Public
W o rk s
E n g in eering & Servic es D ivi s io n
R E
V
IS
E D
R E
C O
R D
D R
A W
IN
G
S
COOLING COIL
C
NO
NC
CWR CWS
2 3
1 PRESSURE TEMPERATUR TAP
2 HOSE END BALL VALVE FOR DRAINING
3 STRAINER
4 BALL VALVE-BALANCE TO EQUAL COIL
PRESSURE DROP IN BYPASS MODE
5 3-WAY TEPMEPATURE CONTROL VALVE
6 AIR VENT
7 BALANCING VALVE
8 ISOLATION VALVE-USE BALL VALVE FOR
PIPING 2" AND SMALLER AND BUTTERFLY
VALVE FOR PIPING 2-1/2" AND LARGER
9 PROVIDE FLANGES OR UNIONS TO ALLOW
FOR COIL REMOVAL
AIR HANDLING UNIT CHILLED WATER COIL PIPING
NOT TO SCALE
10 PRESSURE GAUGE AND
THERMOMETER
CHILLER
STRAINER
1 3
4 6
1 PRESSURE GAUGE
2 AIR VENT
3 FLOW SWITCH
4 BRAIDED STAINLESS STEEL
FLEXIBLE PIPE CONNECTOR
BALL VALVE FOR PIPING 2" AND
SMALLER. BUTTERFLY VALVE FOR
PIPING 2-1/2" AND LARGER
(TYPICAL)
7 UNDERGROUND CHILLED
WATER PIPING
CHILLER DETAIL
NOT TO SCALE
8 THERMOMETER
PROVIDE ALUMINUM JACKET ON
INSULATION INSTALL ABOVE
GROUND
16x16
60"
LINE WITH 1-INCH THICK
1.5-POUND DUCTLINER
RADIUS HEEL
ELBOW
TRANSFER BOOT DETAIL
NOT TO SCALE
TRANSFER BOOT DO NOT
REQUIRE DUCT WRAP
VAV HEATING COIL
HWR
HWS
NC C
NO
PRESSURE-TEMPERATURE
2 DRAIN VALVE
AIR VENT
3-WAY TEMPERATURE CONTROL
VALVE IN DIVERTING CONFIGURATION
COMBINATION STRAINER-FULL PORT
TEST PLUG
BALL VALVE WITH UNION END
CALIBRATED MANUAL BALANCING
MODIFIED VENTURI BALL VALVE
UNION END MEMORY STOP
600WOG Cv-0.66
7 FULL PORT BALL VALVE
600WOG MEMORY STOP
AND UNION END
VAV REHEAT COIL PIPING
NOT TO SCALE
RPP BACKFLOW
PREVENTER
3/4" TO DOMESTIC
WATER LINE
HWR FROM SYSTEM
PRESSURE
REDUCING
VALVE
BALL VALVE TYPICAL
PRESSURE
GAUGE
REFER TO HEATING WATER PUMP DETAIL
SHEET M-502
BOILER ET-2
LOW WATER CUTOFF
FLOW SWITCH
4" PVC VENT AND FLUE
THROUGH ROOF. FLASH
AT ROOF PENETRATION.
TERMINATE IN ACCORDANCE
WITH BOILER MANUFACTURERS
INSTRUCTIONS
HEATING WATER SYSTEM SCHEMATIC
NOT TO SCALE
TEE TO SECOND
HEATING WATER PUMP
PROVIDE CHEMICAL SHOT FEEDER
CONNECTED TO PUMP SUCTION
PIPING AND PUMP DISCHARGE
PIPING
HEATING COIL
HWR
HWS
NC C
NO
PRESSURE-TEMPERATURE
2 DRAIN VALVE
AIR VENT
3-WAY TEMPERATURE CONTROL
VALVE IN DIVERTING CONFIGURATION
COMBINATION STRAINER-FULL PORT
TEST PLUG
BALL VALVE WITH UNION END
CALIBRATED MANUAL BALANCING
MODIFIED VENTURI BALL VALVE
UNION END MEMORY STOP
600WOG Cv-0.66
7 FULL PORT BALL VALVE
600WOG MEMORY STOP
AND UNION END
AIR HANDLING UNIT HEATING COIL PIPING
NOT TO SCALE
8 PRESSURE GAUGE AND
THERMOMETER
24" MIN
4" MIN SAND BEDDING
COVER
6" MIN 6" MIN (TYP)
CHILLED WATER BURIED PIPE
NOT TO SCALE
METALLIC LOCATOR TAPE
SERVICE PIPE SHALL BE 3� SCHEDULE 40
STEEL. PIPE SHALL BE SURROUNDED BY
1.25� OF RIGID POLYURETHANE INSULATION
WITH AN R-VALUE OF AT LEAST R-7. THE
INSULATION JACKET SHALL BE 6� DIAMETER
DURABLE PVC. INSTALL IN ACCORDANCE
WITH MANUFACTURERS WRITTEN
INSTRUCTIONS.
IL
D
IN
G
M-502
H V
A C
D E
T A
IL
S
C o n t r N o
A
B
C
D
1 2 3 4 5
F
IL
E
D A
T E
T
IM
E
D E
S
IG
N F
IL
E
D a t e reference number:
D e s c r i p t i o n D a te
A p p r
M a r k
14024
Sheet
Bldg Nos.
Project No.
DMI No.
W
C
B U
I L
D I N
G
D
IR
E C
T O
R A
T E
O F
P U
B L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G P
L A
N S
A N
D S
E R
V
IC
E S
A
U G
F Y
F
L A
G S
H
IP
P R
O J E
C T
Sheet of 45
D ir ec t or ate of Public
W o rk s
E n g in eering & Servic es D ivi s io n
R E
V
IS
E D
R E
C O
R D
D R
A W
IN
G
S
1 STAINLESS STEEL BRAIDED CONNECTOR
INCREASER OR DECREASER AS REQUIRED
2 PIPE SUPPORT
3 SPING AND NEOPRENE PIPE HANGER
THESE LOCATIONS ONLY ALL OTHER PIPE
HANGERS MAY BE CLEVIS TYPE (TYPICAL)
4 4 PIPE DIAMETERS IN LENGTH
TO SYSTEM
5 FULL PORT BALL VALVE
6 4-PORT PRESSURE INDICATOR WITH
PRESSURE GAUGE
7 1/4" O.D. COPPER TUBING WITH
COMPRESSION FITTINGS
8 STRAINER WITH HOSE END BLOW
OFF VALVE
9 HEATING WATER PUMP
10 HOSE END DRAIN VALVE TYPICAL
11 IN-LINE AIR ELIMINATION FITTING.
MAXIMUM PRESSURE DROP 2 FEET.
12 HIGH CAPACITY AIR VENT
13 EXPANSION TANK ET-2
14 PRESSURE GAUGE
15 BALL VALVE TYPICAL
16 PRESSURE REDUCING VALVE. SET AT 4
PISG HIGHER THAN THE PRESSURE AT
THE HIGH POINT IN THE SYSTEM.
17 GLOBE VALVE
18 RPP BACKFLOW PREVENTER
19 FILL LINE CONNECT TO
DOMESTIC COLD WATER LINE
CALIBRATED MANUAL BALANCING
MODIFIED VENTURI BALL VALVE
UNION END MEMORY STOP
600WOG Cv-0.66
1 1
WHERE SHOWN
HEATING WATER PUMP DETAIL
NOT TO SCALE
NOT USED21
DO NOT INSULATE22
BOILER ROOM
FLOOR
23 24 25
FIELD FABRICATED SUPPORT FOOT
SUPPORT FOOT MUST BE INSTALLED
IN SUCH A WAY AS NOT TO CREATE
ANY STRESSES ON PUMP COMPONENTS.
SUPPORT FOOT SHALL NOT BE RIGIDLY
MOUNTED TO LIMIT ITS ABILITY TO ALLOW
FOR PIPE EXPANSION MOVEMENT.
CONCRETE HOUSE KEEPING PAD
1-INCH NEOPRENE VIBRATION PAD
TO BOILER
REFER TO HEATING WATER SYSTEM
SCHEMATIC SHEET M-501
TEE TO SECOND
HEATING WATER PUMP
TEE TO SECOND
HEATING WATER PUMP
1 STAINLESS STEEL BRAIDED CONNECTOR
INCREASER OR DECREASER AS REQUIRED
2 PIPE SUPPORT
3 SPING AND NEOPRENE PIPE HANGER
THESE LOCATIONS ONLY ALL OTHER PIPE
HANGERS MAY BE CLEVIS TYPE (TYPICAL)
4 4 PIPE DIAMETERS IN LENGTH
TO SYSTEM
5 FULL PORT BALL VALVE
6 4-PORT PRESSURE INDICATOR WITH
PRESSURE GAUGE
7 1/4" O.D. COPPER TUBING WITH
COMPRESSION FITTINGS
8 STRAINER WITH HOSE END BLOW
OFF VALVE
9 HEATING WATER PUMP
10 HOSE END DRAIN VALVE TYPICAL
11 IN-LINE AIR ELIMINATION FITTING.
MAXIMUM PRESSURE DROP 2 FEET.
12 HIGH CAPACITY AIR VENT
13 EXPANSION TANK ET-2
14 PRESSURE GAUGE
15 BALL VALVE TYPICAL
16 PRESSURE REDUCING VALVE. SET AT 4
PISG HIGHER THAN THE PRESSURE AT
THE HIGH POINT IN THE SYSTEM.
17 GLOBE VALVE
18 RPP BACKFLOW PREVENTER
19 FILL LINE CONNECT TO
DOMESTIC COLD WATER LINE
CALIBRATED MANUAL BALANCING
MODIFIED VENTURI BALL VALVE
UNION END MEMORY STOP
600WOG Cv-0.66
1 1
WHERE SHOWN
HEATING WATER PUMP DETAIL
NOT TO SCALE
NOT USED21
DO NOT INSULATE22
BOILER ROOM
FLOOR
23 24 25
FIELD FABRICATED SUPPORT FOOT
SUPPORT FOOT MUST BE INSTALLED
IN SUCH A WAY AS NOT TO CREATE
ANY STRESSES ON PUMP COMPONENTS.
SUPPORT FOOT SHALL NOT BE RIGIDLY
MOUNTED TO LIMIT ITS ABILITY TO ALLOW
FOR PIPE EXPANSION MOVEMENT.
CONCRETE HOUSE KEEPING PAD
1-INCH NEOPRENE VIBRATION PAD
TO BOILER
REFER TO HEATING WATER SYSTEM
SCHEMATIC SHEET M-501
TEE TO SECOND
HEATING WATER PUMP
TEE TO SECOND
HEATING WATER PUMP
M-601
B U
IL
D
IN
G
H V
A C
E Q
U
IP
M E
N T
S C
H E
D U
L E
S
TYPE A
PERFORATED CEILING DIFFUSERS SHALL BE STEEL, FLUSH FACE. DIFFUSERS SHALL
HAVE A PERFORATED FACE WITH 3/16-INCH DIAMETER HOLES ON .25-INCH
STAGGERED CENTERS AND NO LESS THAN 51 PERCENT FREE AREA. PERFORATED
FACE SHALL BE STEEL. THE BACKPAN SHALL BE ONE PIECE STAMPED STEEL OF THE
SIZES AND MOUNTING TYPES SHOWN ON THE PLANS AND SCHEDULE. THE DIFFUSER
NECK SHALL HAVE 1 1/8-INCH DEPTH. PATTERN CONTROLLERS SHALL BE MOUNTED
ON THE BACK OF THE PERFORATED FACE AND MUST BE FIELD ADJUSTABLE TO ALLOW
THE DISCHARGED AIR TO ENTER THE ROOM IN EITHER OR ONE, TWO, THREE OR
FOUR WAY HORIZONTAL JETS. THE FINISH SHALL WHITE, ANODIC ACRYLIC PAINT.
THE PAINT MUST PASS A 100-HOUR ASTM B117 CORROSIVE ENVIRONMENTS SALT
SPRAY TEST. PROVIDE WITH R-6 MOLDED, FOIL BACKED, FIBERGLASS INSULATION
BLANKET.
TYPE B
PERFORATED CEILING PANELS FOR RETURN APPLICATIONS SHALL BE STEEL, FLUSH
FACE. PERFORATED FACE PANELS SHALL HAVE 3/16-INCH DIAMETER HOLES ON
.25-INCH STAGGERED CENTERS AND NO LESS THAN 51 PERCENT FREE AREA. THE
RETURN PANELS SHALL MATCH THE SUPPLY MODELS IN APPEARANCE AND SHALL BE
PROVIDED IN THE SIZES AND MOUNTING TYPE SHOWN ON THE PLANS AND SCHEDULE.
THE FINISH SHALL BE WHITE ANODIC ACRYLIC PAINT.
TYPE C
STEEL, LOUVER FACED CEILING DIFFUSER OF THE SIZES AND MOUNTING TYPES
SHOWN ON THE PLANS AND SCHEDULE. DIFFUSERS SHALL HAVE THREE CONES, WHICH
GIVE A UNIFORM MODULE SIZE AND APPEARANCE WITH DIFFERENT NECK SIZES. ALL
CONES SHALL BE ONE PIECE PRECISION DIE-STAMPED; THE BACK CONE SHALL ALSO
INCLUDE AN INTEGRALLY DRAWN INLET. THE TWO INNER CONES SHALL BE
CONSTRUCTED AS A SINGLE, REMOVABLE INNER CONE ASSEMBLY FOR EASY
INSTALLATION AND CLEANING. THE INNER CONE ASSEMBLY MUST HAVE A HOLE WITH
REMOVABLE PLUG IN THE CENTER TO ALLOW QUICK ADJUSTMENT OF AN OPTIONAL
INLET DAMPER WITHOUT REMOVING THE INNER CONE ASSEMBLY. DIFFUSERS SHALL
BE CONSTRUCTED OF 24-GAUGE STEEL. THE FINISH SHALL BE WHITE ANODIC
ACRYLIC PAINT. PAINT MUST PASS A 100-HOUR ASTM B117 CORROSIVE
ENVIRONMENTS SALT SPRAY TEST. DAMPERS WHERE SPECIFIED SHALL BE OPPOSED
BLADE STEEL. DAMPER MUST BE OPERABLE FROM THE FACE OF THE DIFFUSER.
PROVIDE WITH R-6 MOLDED, FOIL BACKED, FIBERGLASS INSULATION BLANKET.
TYPE D
STEEL RETURN GRILLE, 3/4-INCH BLADE SPACING, OF THE SIZES AND MOUNTING
TYPES SHOWN ON THE PLANS AND SCHEDULE. THE FIXED DEFLECTION BLADES
SHALL BE PARALLEL TO THE LONG DIMENSION OF THE GRILLE. CONSTRUCTION
SHALL BE OF STEEL WITH A 1.25-INCH WIDE BORDER ON ALL SIDES. SCREW HOLES
SHALL BE COUNTERSUNK FOR A NEAT APPEARANCE. CORNERS SHALL BE WELDED
WITH FULL PENETRATION RESISTANCE WELDS. BLADE DEFLECTION ANGLE SHALL BE
35 DEGREES. THE GRILLE FINISH SHALL BE WHITE. THE FINISH SHALL BE AN
ANODIC ACRYLIC PAINT. THE PAINT MUST PASS A 100-HOUR ASTM B117 CORROSIVE
ENVIRONMENTS SALT SPRAY TEST.
GRILLE, REGISTER AND DIFFUSER SPECIFICATIONS
PROVIDE MOTOR SPEED CONTROLLER FOR EACH TYPE A FAN
PROVIDE TYPE B FAN WITH WALL HOUSING, CLOSURE ANGLES, FLUSH EXTERIOR
WITH OSHA GUARD, 120-VOLT DAMPER WITH END SWITCH, AND DAMPER GUARD,
INDOOR UNIT SHALL BE COMPLETE WITH COOLING/HEATING COIL, FAN, FAN MOTOR, PIPING CONNECTORS, ELECTRICAL CONTROLS, MICROPROCESSOR CONTROL SYSTEM, AND INTEGRAL TEMPERATURE SENSING. THE UNIT SIZE RANGE SHALL BE 3/4 TO 2 TON NOMINAL
COOLING CAPACITY AND 3/4 TO 2 TON NOMINAL HEATING CAPACITY. THE SYSTEM SHALL HAVE A MINIMUM LISTED SEER (SEASONAL
ENERGY EFFICIENCY RATIO) OF 13 AT ARI CONDITIONS, AND A MINIMUM HSPF OF 7.7. OUTDOOR UNITS SHALL CONSIST OF A
ROTARY COMPRESSOR, AN AIR--COOLED COIL, PROPELLER--TYPE DRAW--THROUGH OUTDOOR FAN, METERING DEVICE(S), AND
CONTROL BOX. UNITS SHALL DISCHARGE AIR HORIZONTALLY.
SPLIT SYSTEM AIR CONDITIONER UNIT SPECIFICATIONS
C o n t r N o
A
B
C
D
1 2 3 4 5
F
IL
E
D A
T E
T
IM
E
D E
S
IG
N F
IL
E
D a t e reference number:
D e s c r i p t i o n D a te
A p p r
M a r k
14024
Sheet
Bldg Nos.
Project No.
DMI No.
W
C
B U
I L
D I N
G
D
IR
E C
T O
R A
T E
O F
P U
B L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G P
L A
N S
A N
D S
E R
V
IC
E S
A
U G
F Y
F
L A
G S
H
IP
P R
O J E
C T
Sheet of 45
D ir ec t or ate of Public
W o rk s
E n g in eering & Servic es D ivi s io n
R E
V
IS
E D
R E
C O
R D
D R
A W
IN
ELECTRICAL LEGEND
SPECIAL PURPOSE OUTLET
MOTOR, HORSEPOWER, FLA, OR KW AS INDICATED
MANUAL MOTOR STARTERSm
J
REFERENCE TO SPECIAL ELECTRICAL NOTE NO. 1
101 ROOM NUMBER
EXIT SIGN, SINGLE FACE, CEILING OR WALL MOUNTED
S
S
PC
F
SD
D
SD
HEAT DETECTOR, CEILING-MOUNTED
SMOKE DETECTOR, CEILING-MOUNTED
SMOKE DETECTOR, DUCT-MOUNTED
R T
R RELAY, FAN SHUTDOWN
FACP
COMBINATION STARTER, SIZE AS NOTED
H L
TRANSFORMER, SIZE & TYPE AS NOTED
C
PANELBOARD
MANUAL PULL STATION, MOUNT AT 48" AFF
HD
STROBE LIGHT, WALL MOUNTED, 80" AFFL
MAGNETIC MOTOR STARTER, SIZE AS NOTED
HORN & LIGHT, WALL MOUNTED, 80" AFF
THE CONTRACTOR; AND AS A PART OF THIS CONTRACT, THE CONTRACTOR SHALL
PROTECTIVE DEVICE IN THE PANEL, SWITCHBOARD, ETC., EXCEPT AS OTHERWISE
ONLY THAT PORTION ASSOCIATED WITH THE DEMOLISHED DEVICE SHALL BE REMOVED
CONDITION.
TO ITS NEW LOCATION. CONDUIT SHALL BE ROUTED SO AS NOT TO INTERFERE
CONTRACTOR SHALL RELOCATE AND RECONNECT CIRCUITRY ASSOCIATED WITH THE
RELOCATION OF THE ITEM.
NEW LOCATION. PROVIDE CONNECTION OF SUCH RELOCATED ITEMS TO NEW OR
EXTENDED CIRCUITRY AS SHOWN ON THE DRAWINGS.
GENERAL DEMOLITION NOTES:
M
1. REMOVED ELECTRICAL EQUIPMENT AND MATERIALS SHALL BECOME THE PROPERTY OF
2. EACH ITEM OF EQUIPMENT, RECEPTACLES, LIGHT FIXTURES, MOTORS, ETC., SHOWN
D. WHERE SUCH INACCESSIBLE CONDUIT ENDS OR MUST BE TERMINATED IN
3. WHERE ONLY A PORTION OF A CIRCUIT’S LOAD IS SCHEDULED TO BE REMOVED,
4. WHERE EXTENSION OF AN EXISTING CIRCUIT IS REQUIRED, CONDUIT AND WIRE
5. WHERE AN ITEM OF EQUIPMENT IS SCHEDULED TO BE REMOVED AND RELOCATED, ITS
PHOTOELECTRIC CELL, MAST MOUNTED
LIGHTING SENSOR WITH "ON", "OFF" OVERRIDE
REMOVE EQUIPMENT AND MATERIAL OFF THE PROPERTY.
WITH THE USE OR MAR THE AESTHETICS OF THE AREA. WHERE NECESSARY, THE
ALONG WITH ITS ASSOCIATED SWITCHGEAR AND DEVICES, ETC., AND RELOCATED TO THE
ELECTRICAL ABBREVIATIONS
SHALL BE RUN (CONCEALED WHERE POSSIBLE) FROM THE ITEM’S EXISTING LOCATION
AL2-12
F
Q
Z
J
CONCEALED CONDUIT WITH ONE PHASE CONDUCTOR AND
ONE NEUTRAL CONDUCTOR AND A SEPARATE GROUND
CONDUCTOR (GREEN WIRE)
DISCONNECT SWITCH (NON-FUSED, UNLESS
OTHERWISE NOTED), SIZE AS NOTED
JUNCTION BOX (FLUSH-MOUNTED UNLESS OTHERWISE
NOTED), WITH COVER
WALL-MOUNTED FIXTURE; LETTER DENOTES TYPE IN
FIXTURE SCHEDULE
EXIT SIGN, DOUBLE FACE, WITH DIRECTIONAL ARROWS,
CEILING-MOUNTED
WALL SWITCH, SINGLE POLE, 20A, 120/277 VOLT;
WP= WEATHERPROOF, MOUNT AT 48" AFF
REMOTE TEST SWITCH FOR DUCT SMOKE DETECTOR
F
CONDUIT WITH HOMERUN ARROW TO BREAKER NO. 12
IN PANEL "AL2"
DUPLEX RECEPTACLE, WEATHERPROOF,
MOUNT 24" ABOVE FINISHED FLOOR
WALL SWITCH, 3-WAY; 4= 4-WAY; 2= DOUBLE-POLE;
P= PILOT LIGHTED HANDLE, MOUNT AT 48" AFF
FIRE ALARM CONTROL PANEL, SEMI-RECESSED IN
WALL, WITH TOP AT 5’-10" AFF
C. WHERE CONDUIT IS ASSOCIATED WITH AN ITEM SHOWN TO BE REMOVED AND
TO A POINT WHERE THE REMAINING LOAD IS ACTIVE AND IN GOOD OPERATING
ASSOCIATED CIRCUITRY SHALL ALSO BE REMOVED IN ACCORDANCE WITH NOTE 2 ABOVE,
MENTIONED IN NOTES 3 AND 4 BELOW.
DUPLEX RECEPTACLE, 20A, 125V, GROUNDED-TYPE,
MOUNT 18" ABOVE FINISHED FLOOR UNLESS OTHERWISE NOTED.
IG = ISOLATED GROUND TYPE
GFI = GROUND FAULT INTERRUPTER TYPE
EXISTING MANUAL FIRE ALARM STATION TO BE REMOVED
EXISTING MOTOR STARTER TO BE REMOVED
EXISTING INCANDESCENT LIGHT TO BE REMOVED
EXISTING 3-WAY WALL SWITCH TO BE REMOVED
EXISTING WALL SWITCH TO BE REMOVED
EXISTING EXIT LIGHT TO BE REMOVED
EXISTING 1’x 4’ FLUORESCENT FIXTURE TO BE REMOVED
EXISTING 2’x 4’ FLUORESCENT FIXTURE TO BE REMOVED
EXISTING MOTOR TO BE REMOVED
EXISTING DISCONNECT SWITCH TO BE REMOVED
EXISTING PANELBOARD TO BE REMOVED
EXISTING JUNCTION BOX TO BE REMOVED
EXISTING TELEPHONE OUTLET TO BE REMOVED
EXISTING SPECIAL PURPOSE OUTLET TO BE REMOVED
EXISTING DUPLEX RECEPTACLE TO BE REMOVED
ACCESS CONTROL PANEL
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AIR HANDLING UNIT
AMPERE
APPROXIMATE
ARCHITECTURAL
AUTOMATIC
AMERICAN WIRE GAUGE
AUTOMATIC TRANSFER SWITCH
ALUMINUM
ACP
AFF
AFG
AHU
AMP, A
APPROX
ARCH
AUTO
AWG
ATS
ALUM
BELOW FINISHED GRADE
BUILDING
BFG
BLDG
CONDUIT
CABINET
CIRCUIT BREAKER
CLOSE CIRCUIT TELEVISION
CHILLED WATER PUMP
CIRCUIT
CEILING
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
COPPER
C
CAB
CB
CCTV
CHP
CKT
CLG
CMU
COL
CONC
CU
DETAIL
DIAMETER
DIMENSION
DISCONNECT
DOWN
DRAWINGS
DET
DIA
DIM
DISC
DN
DWGS
FIRE ALARM CONTROL PANEL
FAN COIL UNIT
FLOOR
FULL LOAD AMPERES
FLEXIBLE
FLUORESCENT
FOOT: FEET
FACP
FCU
FL, FLR
FLA
FLEX
FLUOR
FT
GAUGE
GALVANIZED
GROUND FAULT INTERRUPTER
GROUND
GA
GALV
GFI
GRND
HANDICAPPED
HIGH INTENSITY DISCHARGE
HAND OFF AUTOMATIC SWITCH
HORSEPOWER
HIGH PRESSURE SODIUM
HEIGHT
HEATER
HOT WATER
HOT WATER PUMP
HC
HID
HOA
HP
HPS
HT
HTR
HW
HWP
IN ACCORDANCE WITH
ISOLATED GROUND
INCANDESCENT
JUNCTION BOX
THOUSAND CIRCULAR MILS
KILOVOLT
KILOVOLT AMPERES
KILOWATT
KILOWATT HOUR
IAW
IG
INCAND
J-BOX
kcmil kV kVA kW kWH
LIGHT EMITTING DIODE
LINEAL FOOT
LOW VOLTAGE
MAXIMUM
MAIN CIRCUIT BREAKER
MOTOR CONTROL CENTER
THOUSAND CIRCULAR MILS
MANUFACTURER
METAL HALIDE
MINIMUM
MAIN LUGS ONLY
MOUNTING
METER
MILLIMETER
LED
LF
LV
MAX
MCB
MCC
MCM
MFR
MH
MIN
MLO
MTG
m mm
NORMALLY CLOSED
NATIONAL ELECTRICAL CODE
NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION
NON-FUSED
NORMALLY OPEN
NOMINAL
NOT TO SCALE
NOT IN CONTRACT
ON CENTER
OPPOSITE HAND OR OVERHEAD
OPPOSITE
POLE
PUSHBUTTON
POWER FACTOR
PHASE
PANEL
PRIMARY
POLYVINYL CHLORIDE
NC
NEC
NEMA
NF
NO
NOM
NTS
NIC
OC
OH
OPP
P
PB
PF
PH, 0
PNL
PRIM
PVC
ELECTRICAL GENERAL NOTES
EACH
EXHAUST FAN
ELECTRICAL
ELEVATION: ELEVATOR
ENCLOSURE
EXPLOSIVE PROOF
EQUAL
EQUIPMENT
ELECTRICAL WATER COOLER
EXHAUST
EXTERIOR
EA
EF
ELEC
ELEV, EL
ENCL
EP
EQ
EQUIP
EWC
EXH
EXT
E-001
A. ASSOCIATED CIRCUITRY SHALL BE DEFINED TO INCLUDE ALL CONDUIT,
CONDUCTORS, BOXES, WIRING DEVICES, COVERPLATES, LAMPS, FIXTURES,
WIREWAYS, SWITCHES, STARTERS, ETC., THAT ARE ASSOCIATED WITH THE
ITEM SHOWN TO BE REMOVED.
B. THE PROTECTIVE DEVICE SHALL REMAIN AS AN INTEGRAL PART OF THE
EXISTING PANEL, SWITCHBOARD, ETC., AND SHALL BE LABELED AS A SPARE
OR BE USED FOR NEW CIRCUITRY AS SHOWN.
1. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CONFIRM COMPATIBILITY BETWEEN
CEILING TYPE, AS DEFINED ON THE ARCHITECTURAL ROOM FINISH SCHEDULE AND LIGHT FIXTURE
TRIM AS DEFINED ON THE FIXTURE SCHEDULE. HOWEVER, NO CHANGE OR DEVIATION SHALL BE
MADE FROM THE CONTRACT DOCUMENTS WITHOUT PRIOR APPROVAL.
2. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE TO THE PROPER SIDE OF
THE DOOR ANY SWITCH, RECEPTACLE OR DEVICE BEING AFFECTED BY ANY CHANGE IN DIRECTION
OF DOOR SWINGS AS SHOWN ON THE ARCHITECTURAL FLOOR PLANS.
3. LIGHTING IN MECHANICAL ROOMS SHALL BE ADJUSTED IN FIELD FOLLOWING INSTALLATION OF
MECHANICAL AND ELECTRICAL EQUIPMENT TO PROVIDE RELATIVELY UNIFORM LIGHTING AS
GENERALLY OUTLINED ON THE DRAWINGS.
4. REMOTE MOUNTED MOTORS SHALL BE PROVIDED WITH RECEPTACLE AND PLUG OR DISCONNECT
SWITCH TO BE COMPATIBLE WITH TYPE CONSTRUCTION AND N.E.C.
5. EACH MOTOR BEING INSTALLED ON THIS CONTRACT SHALL BE PROVIDED WITH THERMAL OVERLOAD
PROTECTION IN EITHER A MANUAL OR MAGNETIC STARTER. THERMAL ELEMENTS SHALL BE SIZED
AND INSTALLED ACCORDING TO THE FLA OF EACH MOTOR.
6. KILOWATT (kW) RATINGS FOR EQUIPMENT MOTOR LOADS OF 4kW AND LARGER ARE AS DESIGNED
WITH 95% POWER FACTOR RATING ASSUMED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
INCREASING FOR LOADS 4kW AND LARGER, AS REQUIRED OF ALL FEEDERS AND PROTECTIVE
DEVICES SERVING ANY ITEM OF EQUIPMENT SUPPLIED WITH POWER FACTOR RATINGS LESS THAN 95%.
7. IN ALL AREAS THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION BETWEEN THE
ELECTRICAL AND MECHANICAL TRADES TO PROVIDE CLEARANCES ABOVE CEILING BETWEEN RECESSED
LIGHT FIXTURES AND THERMAL INSULATION IN ACCORDANCE WITH N.E.C. PARAGRAPH 410-66.
8. THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF LIGHT FIXTURES WITH
REFLECTED CEILING PLANS FOR EXACT LOCATION OF FIXTURES. IT SHALL ALSO BE THE
CONTRACTOR’S RESPONSIBILITY TO COORDINATE WITH THE MECHANICAL CONTRACTOR AND OTHER
TRADES TO ENSURE THE PROPER INSTALLATION OF LIGHT FIXTURES, AIR DIFFUSERS, FIRE ALARM
DEVICES AND OTHER ITEMS SHOWN ON THE PLANS TO BE INSTALLED IN OR ON THE CEILING.
9. EQUIPMENT SIZES ARE AS DESIGNED. CIRCUIT BREAKERS, CONDUIT, MOTOR STARTERS,
DISCONNECT SWITCHES AND CONDUCTOR SIZES, ETC. SHALL BE ADJUSTED TO THE
EQUIPMENT SUBMITTED AND APPROVED FOR INSTALLATION ON THIS PROJECT.
THIS SHALL INCLUDE THE FOLLOWING:
A. MECHANICAL SYSTEM EQUIPMENT (INCLUDES PLUMBING SYSTEM)
B. AUTOMATIC FIRE ALARM SYSTEM EQUIPMENT
TO BE DEMOLISHED SHALL HAVE ITS ASSOCIATED CIRCUITRY REMOVED BACK TO THE
RECEPTACLE
ROOM
RAPID START
RETURN AIR
SECONDARY
SHEET
SOLID NEUTRAL
STANDARD
STEEL
SWITCH
SYSTEM
SUPPLY AIR
SWITCHBOARD
TELEPHONE
THICK
TELEPHONE TERMINAL BOARD
TYPICAL
UNDERGROUND
UNIT HEATER
UNDERWRITERS LABORATORY
UNINTERRUPTABLE POWER
SUPPLY
VOLTS
VOLT-AMPERE
WATTS: WIDE: OR WIRE
WEATHER PROOF
PHASE
SINGLE PHASE
THREE PHASE
REC
RM
RS
R/A
SEC
SHT
SN
STD
STL
SW
SYS
S/A
SWBD
TEL
THK
TTB
TYP
UG
UH
UL
UPS
VA
W
1 0
3 0
IS IN AN INACCESSIBLE AREA SUCH AS ENCASED IN CONCRETE, ONLY THAT
INACCESSIBLE CONDUIT SHALL BE ABANDONED IN PLACE. ALL CONDUCTORS
SHALL BE REMOVED, THEN CONDUIT SHALL BE SEALED, CAPPED
OR OTHERWISE TERMINATED IN A SAFE MANNER ACCEPTABLE TO THE
CONSTRUCTION MANAGER OR AS OTHERWISE STATED IN ITEM 2D BELOW.
FINISHED SPACE, THE CONDUIT OR J-BOX SHALL BE REMOVED TO BELOW THE
FINISHED SURFACE OF WALL, CEILING OR FLOOR. THEN VOID SHALL BE
FILLED WITH NON-SHRINKING GROUT, RESURFACED, AND REFINISHED TO
MATCH SURROUNDING SURFACES.
FIRE ALARM BELL TO BE REMOVED
COMMUNICATION OUTLET, DUAL RJ-45
B
FLUORESCENT FIXTURE WITH BUILT-IN BATTERY
COMMUNICATION DUAL R.J.-45 OUTLET, 18" AFF, UNLESS
OTHERWISE NOTED
FLUORESCENT FIXTURE; LETTER DENOTES TYPE IN
FIXTURE SCHEDULE
INCANDESCENT COMPACT FLUORESCENT, OR HID FIXTURE,
CEILING-MOUNTED; LETTER DENOTES TYPE IN FIXTURE
SCHEDULE
FLORESENT DIMING SWITCH
COMBINATION POWER COMMUNICATION POLE FOR SYSTEM
FURNITURE WITH 2 OUTLETS AND TWO DUAL
COMMUNICATION OUTLETS.
D
PC
A
B
C
D
1 2 3 4 5
TITLE BLOCK SIZE 34 x 22 reference number:
14024
Sheet
Bldg Nos.
Project No.
DMI No.
Sheet of 45
ED-101
SCALE: 1/8" = 1’-0"
ED-101 ED-101
C
C
S S S
S S S
S S S
S S S
S S S
S S S
F
F
F
F
F
SOUND AMPLIFIER
PANEL LC2
LIGHT
BAR
F
LIGHT
BAR
PANEL LC-1
FACP
PANEL
DP
PANEL
EP1
PANEL
F
EF
EF
B F
B C
F
PANEL
CHILLER
PP
PP
PP
PP
B
F
PP
PP
PP
ELECTRICAL DEMOLITION PLAN (POWER)
0’ 5’12" 10’ 15’ 20’ 25’
SCALE: 1/8 INCH = 1 FOOT
ROOM
MECHANICAL
1 2 3 4 5 6 7
A
B
C
D
A
B
C
D
1 2 3 4 5
TITLE BLOCK SIZE 34 x 22 reference number:
14024
Sheet
Bldg Nos.
Project No.
ED-102
ED-102 ED-102
0’ 5’12" 10’ 15’ 20’ 25’
SCALE: 1/8 INCH = 1 FOOT
ELECTRICAL DEMOLITION PLAN (LIGHTING)
ROOM
MECHANICAL
1 2 3 4 5 6 7
A
B
C
D
A
B
C
D
1 2 3 4 5 reference number:
14024
Sheet
Bldg Nos.
Project No.
E-101
E-101 E-101
1 ELECTRICAL POWER PLAN
GFI
GFI
WP
GFI
WP
GFI
WP
GFI
ENLARGED PLAN SCALE: 1/4 = 1’-0"
E-101 E-101
11 12
F
J
C-19
PANEL C
C-12,14,16
C-21
F
C-18,20
J
F
J
C-11,13,15
F
B-17
B-13,15
B-19,21
F
A-20,22
J
A-23,25,27
PANEL
"A"
J A-14,16
F
A-19,21
A-13,15,17
13 15
A-18
F
PANEL
"B"
B-14
B-23,25,27
B-26
FOR ENLARGED
PLAN, SEE
E-101 E-101
H L F
HD
WP
GFI
NEW PANEL "M"
FIRE ALARM
TRANSMITTER
NEW FIRE
ALARM CONTROL
PANEL
PANEL
MDP
EXISTING
COMMUNICATION
PANEL BACKBOARD
H L
H L
H L
H L
L
L
H L
H L H L
H L
H L
S S
S
S
S
EF-2
EF-3
EF-4
B-16
B-18
VAV-16
A-7
3VAV-1
VAV-2
EF-1
VAV-3
J
VAV-5
CWP-1
M-20,22,24
1/3
SF-1
UH-1
M-4 M-6
M-14,16,18
AHU
M-13,15,17
M-19,21,23
2 2
HWP-1HWP-2
J
BOILER
M-12
M-11
M-9
0’ 5’12" 10’
SCALE: 1/4 INCH = 1 FOOT
0’ 5’12" 10’ 15’ 20’ 25’
SCALE: 1/8 INCH = 1 FOOT
(MECHANICAL ROOM)
M-8
103 102
135134
142143
132 137
SPECIAL ELECTRICAL NOTES: (SHEET E-101 ONLY)
SDSD
3 ENLARGED PLAN SCALE: 1/4 = 1’-0"
E-101 E-101 (COMMUNICATIONS ROOM)
145124
B-39
CU-1
(14.0 FLD)
EVAP-2
(1.2 A)
B-34 B-28,30
B-37 (1.2A)
B-33,35
EVAP-1
(1.2 A)
CU-2
(14.0 FLD)
B-32
HD
(MECHANICAL ROOM)
J
VAV-14
J
VAV-17
C-22
VAV-13
VAV-12
VAV-11
J
J
VAV-9
J
VAV-10
SEE DETAIL
FOR
ENLARGED
PLAN OF THIS AREA
E-101 E-101
J
VAV-7
B-3812
B-36
U S
US
CH-1 WP
GFI
MDP-13,15,17
A-24
13 20
J
B-20,22
B-36
VAV-8
B-24
3 3
J
J
VAV-4
J
J
VAV-6
J
E L
E C
T R
IC
A
L P
O W
E R
P L
A N
P L
A N
N O
R T
H
P L
A N
N O
R T
H
P L
A N
N O
R T
H
S
23,25
B-29,31
NEW FIREALARM
ANTENNA MONACO
BX-F
S
M-8
MOUNT 48" ABOVE FINISHED FLOOR.
FLUSH MOUNT RECEPTACLES IN LAY-IN CEILING FOR FUTURE
PROJECTOR.
PROVIDE CONNECTION FOR VAV BOX, COORDINATE WITH MECHANICAL
TRADE FOR ROUGH-IN.
MOUNT 24" ABOVE FINISHED GRADE.
CONDUIT ROUGH-IN WITH
RECEPTACLES FOR ELECTRICAL WATER COOLER, COORDINATE ROUGH-IN
WITH COOLER INSTALLATION.
LOCATE RECEPTACLES 48" ABOVE FINISHED FLOOR FOR VENDING
MACHINES.
CONTROL CIRCUIT FOR HOT WATER BOILER.
PROVIDE 30A, 3P, NF, 250 VOLT DISCONNECT SWITCH IN NEMA 1
ENCLOSURE.
PROVIDE NEMA SIZE "0", 3P, 200 VOLT MAGNETIC MOTOR STARTER IN
NEMA 1 ENCLOSURE.
PROVIDE NEMA SIZE "1", 3P, 200 VOLT MAGNETIC MOTOR STARTER IN
NEMA 1 ENCLOSURE.
PROVIDE 120 VOLT NEC DISCONNECT SWITCH.
MOUNT OUTLET 6" ABOVE COUNTER TOP.
COORDINATE LOCATION OF ELECTRICAL CONNECTION WITH MECHANICAL
DRAWINGS.
MOUNT RECEPTACLE ON CHILLER SCREEN WALL.
PROVIDE 200A, 3P, 250V, NF, DISCONNECT SWITCH IN NEMA 3R
ENCLOSURE.
PROVIDE 2 DUPLEX RECEPTICLE IN POWER/COMMUNICATION POLE FOR
FUTURE SYSTEMS FUTURE CONNECTION.
PROVIDE TWO DUAL COMMUNICATION OUTLETS IN POWER/COMMUNICATION
POLE FOR FUTURE SYSTEMS FUTURE CONNECTION.
2 # 10 & 1 #10 GROUND IN 1/2" C
3 #8 & 1 #10 GROUND IN 1" C
MOUNT ELECTRICAL AND COMMUNICATION ABOVE DESKTOP.
GFCI GFCI
GFCI
GFCI
PC
A-26
PC
A-26
PC
B-41
PC
B-41
PC
C-21
PC
A-26
PC
C-23
PC
C-23
IT
E
M R
E M
O V
E D
-1
-0
M
A L
S
1 2 3 4 5 6 7
A
B
C
D
C o n t r N o
A
B
C
D
1 2 3 4 5
TITLE BLOCK SIZE 34 x 22
F
IL
E
D A
T E
T
IM
E
D E
S
IG
N F
IL
D a t e reference number:
D e s c r i p t i o n
D a te
A p p r
M a r k
14024
Sheet
Bldg Nos.
Project No.
DMI No.
W C
B U
I L
D I N
G
D
IR
E C
T O
R A
T E
O F
P U
B L
IC
W
O R
K S
E N
G
IN
E E
R
IN
G P
L A
N S
A N
D S
E R
V
IC
E S
Sheet of 45
F Y
F
L A
G S
H
IP
P R
O J E
C T
A
U G
R E
V
IS
E D
R E
C O
R D
D R
A W
IN
E-102
E-102 E-102
1 ELECTRICAL LIGHTING PLAN
A
AA
A
A
AA
A A
A A A
A
A
B
A
A
A A
A
A A A A
A A A A A A
AAA
A A A
AAA
AAA
A A
AA
B
D
D
D
D
DD
D
AA
A
A A
B
B
A A
AA
A
A
A
B
A
A A
A A
A A
A A
A
BBBEB
BE
B B
BE
B
A
A
A
A
A
AA
A A
AA
AA
A A
AA
B B
B
BE
A
A
A
A BE
BE
A A
C
B
BE
BE
BE
BE
BE
E
E
E
E
E
E
E
S
S
S
S
S
S
S
B
S
D
E
E
A
A
A
A
C
C
C
C
C
C
C
E-102 E-102
2 NIGHT LIGHTING CONTROL SCHEMATIC
NO SCALE
M-1
M-3
M-5
TO
EXTERIOR
LIGHTS
PROVIDE 4 POLE RELAY
20A, 250 VOLT WITH
120 VOLT CONTROL COIL
C
HAND-OFF-AUTO
SWITCH IN NEMA
ENCLOSURE
HI
N
H
A
O
PHOTO ELECTRIC CELL
SPECIAL ELECTRIC
KEYED NOTES: (SHEET E-102 ONLY)
E-102 E-102
H
E
M-1
E E
C-4,6
PANEL C
C-2
C
C-1,3,5
C
H
M-1
H H
M-1
E
B-5
3 1
H P M-3
C
C
H
M-2
H M-3
C
A-1,3,5
H
M-3
A-2
M-2
H
M-3
C
A-4,6
C C
G
G
G
G
CB-3
PANEL M
PANEL A
C
C
B-4
M-7
C C
C
C
C C C
C C
C
C
C
E
BE
B-2
FROM
PANEL
M
110109
135134
142143
140PANEL B
145124
FUTURE
E
A
AA A
AA A
C
B-6
BE
C
E1
B
EC
C
C
B
S3
C
0’ 5’12" 10’ 15’ 20’ 25’
SCALE: 1/8 INCH = 1 FOOT
S
A-9
M-1
S
EMERGENCY LIGHT SCHEMATIC NO SCALE
E-102 E-102
BALLAST
BATTERY
TYPE "BE"
LIGHT
FIXTURE
AUTOMATIC
TRANSFER
SWITCH
OCCUPANCY
SENSOR OR
LIGHT
SWITCH
SENSOR
H1
N
TO CIRCUIT INDICATED THRU NIGHT
LIGHTING CONTROL SYSTEM, SEE
DETAIL .
LIGHT FIXTURE LOCATIONS IN
MECHANICAL ROOM SHALL BE COORDINATED
WITH MECHANICAL EQUIPMENT.
MOUNT 8’-0" ABOVE FINISHED GRADE.
2 #10 & 1 #10 GROUND IN 1/2" C4
A-10
B-1
P P P P P P
P
P
PP
P
P
PP
PP
S
E1
1 2 3 4 5 6 7
A
B
C
D
A
B
C
D
1 2 3 4 5
TITLE BLOCK SIZE 34 x 22 reference number:
14024
Sheet
Bldg Nos.
Project No.
E-501
NO SCALE1 ELECTRICAL RISER DIAGRAM (DEMOLITION)
E-501 E-501
NO SCALE2 ELECTRICAL RISER DIAGRAM (NEW WORK)
E-501 E-501
PANEL
MDP
PANEL
"M"
PANEL
A
PANEL
B
PANEL
C
SPECIAL ELECTRICAL NOTES: (SHEET E-501 ONLY)
PANEL
MDP
PANEL
"M"
PANEL
A
PANEL
B
PANEL
C
2 2 2 2 2
CH-1
(47 KW)
REFER TO MOTOR SCHEDULE
FOR CONDUIT/WIRE SIZE
REMOVE EXISTING
CHILLER SWITCHGEAR
EXIST 225 KVA PAD
MTD TRANSFORMER
TO REMAIN (208/120V SECONDARY)
EXIST 225 KVA PAD
MTD TRANSFORMER
TO REMAIN (208/120V SECONDARY)
EXISTING PANELBOARD AND FEEDER TO BE REMOVED.
EXISTING PANELBOARD TO BE REMOVED.
REMOVE EXISTING FEEDER WIRING BETWEEN EXISTING PAD-MOUNTED
TRANSFORMER AND PANEL MDP, UTILIZING EXISTING CONDUITS FOR NEW
PANEL MDP FEEDER. NEW FEEDER TO CONSIST OF 2 SETS OF 4 #350
kcmil AND 1 #2 GROUND IN TWO 3" EXISTING CONDUITS.
PROVIDE 1 #4/0 GROUND IN 3/4" CONDUIT.
PROVIDE 3/4" x 10’-0" COPPER CLAD GROUND ROD.
EXISTING PRIMARY TO BE REMOVED AND BE REUSED FOR EXISTING
TRANSFORMER.
EXISTING CONCRETE PAD IS PRESENTLY NOT LEVEL. THE CONTRACTOR
SHALL REMOVE THE EXISTING PAD MOUNTED TRANSFORMER AND REMOVE
EXISTING CONCRETE PAD AND REINSTALL THE EXISTING PAD- MOUNTED
TRANSFORMER ON THE NEW PAD. SEE ELECTRICAL SITE PLAN FOR
DETAILS.
4 #2 AND 1 #8 GROUND IN 1 1/2" C.
NEW KWH METER, REFER TO SITE PLAN FOR
REQUIREMENTS.
PROVIDE 200A, 3P, 250V, NF DISCONNECT SWITCH
FOR NEW CHILLER. (NEMA 3R ENCLOSURE)
FINISHED FLOOR
OR GRADE
A
B
C
D
1 2 3 4 5
TITLE BLOCK SIZE 34 x 22 reference number:
14024
Sheet
Bldg Nos.
Project No.
E-502
NO SCALE
E-502 E-502
NO SCALE3
F F
FINISHED FLOOR
B
BACK-UP
BATTERY
CABINET
TRANSMITTER
ANTENNA
H
L
H
L
H
L
L
FIRE ALARM RISER DIAGRAM
F FFF F F
H
L
H
L
H
L
L
R
SD
NO SCALECOMMUNICATION RISER DIAGRAM
E-502 E-502
COMMUNICATION RISER DIAGRAM (CONT)
SD
D
125 128109 112 127 130 131
H
L
H
L
H
L
132 137 141
H
L
SD
D
AHU FAN
SHUTDOWN
RELAY
NO SCALE
ATTIC SPACE
FINISHED FLOOR
E-502 E-502
109 110 133 135 138
COMMUNICATION RISER DIAGRAM (SIPR)
E-502 E-502
ATTIC SPACE
132 133 134 135 138 139 141 142 143
FINISHED FLOOR
127 130 131 137120109 112 141
SD HD HD
145 127
M-9
FIRE NOTES:
ATTIC SPACE
FINISHED FLOOR
101 102 103 104 113 114105100 111 115 116 118
109 110
116112
RF TRANSMITTER LOCATE ANTENNA ON ROOF (FIELD VERIFY).
MECHANICAL ROOM FR TRANSMITTER SHALL BE MONACO ENTERPRISES
MODEL BT-XF (COORDINATE FREQUENCY AND ANTENNA LENGTH WITH
FORT HOOD FIRE DEPARTMENT) WITH RF TRANSMITTER SUPERVISING
RECEIVING EQUIPMENT.
COORDINATE WITH FORT HOOD FIRE DEPARTMENT TO ESTABLISH A ZONE
SCHEDULE FOR MONACO TRANSMITTER PRIOR TO MAKING SYSTEM
OPERATIONAL.
THE FIRE ALARM SYSTEM SHALL NOT USE PROPRIETARY PROGRAMMING
SOFTWARE. THE FIRE ALARM SYSTEM SHALL BE FULLY PROGRAMMABLE
FROM THE FLAP KEYPAD/DISPLAY.
PULL STATIONS SHALL HAVE A CAT-15 KEY LOCK AND RESET. DO NOT
UTILIZE BREAK GLASS OR RODS, OR SPECIAL TOOLS TO RESET.
FIRE ALARM CONTROL PANEL SHALL BE INSTALLED 1AW
MANUFACTURER’S SPECIFICATIONS AS WELL AS CURRENT NFPA 70 AND
72.
ALL FIRE WIRING TO BE CLASS A.
ALL FIRE DEVICES TO BE INSTALLED AT END OF FROJECT AFTER ALL
PAINTING AND CLEANING IS COMPLEATED.
POWER/COMMUNICATION
POLE
POWER/COMMUNICATION
POLE
POWER/COMMUNICATION
POLE
POWER/COMMUNICATION
POLE
PLYWOOD
BACKBOARD
ROOM 145
FIRE
ALARM
CONTROL
PANEL
PLYWOOD
BACKBOARD
ROOM 124
A
B
C
D
1 2 3 4 5
TITLE BLOCK SIZE 34 x 22 reference number:
14024
Sheet
Bldg Nos.
Project No.
E-503
GENERAL REQUIREMENTS
OUTSIDE PLANT (MECHANICAL ROOM)
BUILDING COMMUNICATIONS WIRING
SIPR COMMUNICATIONS WIRING
CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIAL, AND
EQUIPMENT REQUIRED TO INSTALL COMMUNICATIONS
INFRASTRUCTURE TO MAKE THE FACILITY COMPLETE AND
USABLE PRIOR TO THE SPECIFIED BOD.
CONTRACTOR SHALL FOLLOW ALL TIA/EIA AND RUS
STANDARDS COVERING ALL INSTALLATION ASPECTS OF
COMMUNICATIONS INFRASTRUCTURE. IN ADDITION TO THE
INDUSTRY STANDARDS, THE CONTRACTOR SHALL FOLLOW
THE GUIDANCE PUBLISHED BY THE DIRECTORATE OF
INFORMATION MANAGEMENT (DOIM).
CONTRACTOR SHALL REMOVE ALL CARBON BASED COPPER
PROTECTOR UNITS AND 66 PUNCH DOWN BLOCKS BEING
CAREFUL NOT TO DESTROY THE OSP COPPER.
CONTRACTOR SHALL REMOVE THE METALLIC ENCLOSURE
THAT SURROUNDED THE PROTECTOR UNIT AND 66 PUNCH
DOWN BLOCKS. CONDUITS NO LONGER REQUIRED SHALL BE
REMOVED. (SEE PHOTO)
CONTRACTOR SHALL MOUNT A CIRCA COPPER
PROTECTOR UNIT OF APPROPRIATE SIZE ON A PLYWOOD
BACK BOARD AND RE-TERMINATE THE OSP COPPER PER
DIRECTORATE OF INFORMATION MANAGEMENT IDG. (SEE
PHOTO)
CONTRACTOR SHALL SECURE AN APPROPRIATE GAUGE
GROUND WIRE BETWEEN THE PROTECTOR UNIT AND THE
GROUND BUS BAR. ALL SYSTEMS INSTALLED MUST
CONFORM TO NEC AND ANSI/TIA/EIA-607, COMMERCIAL
BUILDING GROUNDING AND BONDING REQUIREMENTS FOR
TELECOMMUNICATIONS.
CONTRACTOR SHALL REMOVE ALL EXISTING CATEGORY
3 CABLE FROM THE CONDUITS AND DISPOSE OF IT.
CONTRACTOR SHALL RELOCATE THE FIBER OPTIC CABLE
AND LIU ON THE SAME BACK BOARD AS THE COPPER
PROTEC…