A1.2_Drawings_Part8.pdf
PDF 8 MB Posted
- Attached to
- Fort Hood 69th ADA SSA Warehouse Federal contract opportunity
- Solicitation number
- W9126G19B0029
About this file
This document package contains construction drawings and specifications for electrical work at the Fort Hood 69th ADA SSA Warehouse. The project involves installing new primary distribution systems, pad-mounted and interior transformers, panelboards, lighting, communications cabling, lightning protection, and grounding systems. Drawings show site plans, one-line diagrams, lighting plans by area, and construction details. Specifications identify general scope and coordination requirements for the electrical work. The solicitation number is W9126G19B0029 and was issued by the U.S. Army Corps of Engineers Engineering District Fort Worth for the work.
Part 8 of 10
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| C1_Bid_Abstract_19B0029.pdf | ||
| Amendment_3.pdf | ||
| Amendment_2.pdf | ||
| Amendment_1.pdf | ||
| G2_W9126G19B0029.pdf | ||
| A1.2_Drawings_Part1.pdf | ||
| A1.2_Drawings_Part4.pdf | ||
| A1.2_Drawings_Part10.pdf | ||
| A1.2_Drawings_Part2.pdf | ||
| A1.2_Drawings_Part3.pdf | ||
| A1.2_Drawings_Part9.pdf | ||
| A1.2_Drawings_Part5.pdf | ||
| A1.2_Drawings_Part6.pdf | ||
| A1.2_Drawings_Part7.pdf | ||
| G2.20_W9126G19B0029.pdf |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MI-603
G
W O
O D
A R
D P .E
G
W O
O D
A R
D P .E
K
W
IL
L
IA
M S P .E
LDP AND M&C DISPLAY OVERRIDES ALARMS
LDP
VIEW
REQ’D
M&C
SNVT
NAME
SNVT
TYPE
LDP
OVRD
REQ’D
M&C
OVRD
REQ’D
ALARM CONDITION
(SEE
NOTES)
ALARM
PRIORITY
M&C
ROUTING
BLDG
ROUTING
REQ’D
SETTING
(WITH
UNITS)
RANGE
(WITH
UNITS)
NCI/CPT
NAME
IO
TYPE
DISP
REQ’D
TREND
REQ’D
SNVT
NAME
SNVT
TYPE
ON/OFF BI ~ X [~] <___> <___> ~ ~ ~ ~ SUPPLY FAN PROOF FAILED ~ <___> ~
ON/OFF BI ~ ~ ~ ~ ~ X ~ ~ ~ ~ ~ <___> ~
~ NVI ~ X ~ <___> <___> ~ ~ ~ ~ ~ ~ ~ ~
ON/OFF BO ~ ~ ~ <___> <___> ~ ~ <___> <___> ~ ~ ~ ~
<___> AI X X X <___> <___> ~ ~ ~ ~
** SA-T IS MORE THAN 10 DEG
F (ADJ) ABOVE OR BELOW
SA-T-SP
55 DEG F (ADJ) ~ ~ ~ X ~ <___> <___> ~ X <___> <___> ~ ~ <___> ~
ALM/NORMAL BI ~ ~ ~ <___> <___> ~ ~ ~ ~ DIRTY FILTER <___> <___> ~
<___> NVI X X X <___> <___> ~ X ~ ~ ~ <___> <___> ~
FUNCTION NAME DESCRIPTION
PROOFS
AND
SAFETIES
SF-S SUPPLY FAN STATUS ~
EMERGENCY SHUTDOWN
SWITCH
RST-BUT
SYSTEM RESET BUTTON
(FOR SAFETIES)
START/STOP
SYS-OCC
OCCUPANCY INPUT (FROM
SYSTEM SCHEDULER)
SF-SS SUPPLY FAN START/STOP ~
SUPPLY AIR
TEMPERATURE
SA-T SUPPLY AIR TEMPERATURE ~
SA-T-SP
SUPPLY AIR TEMPERATURE
SET POINT
OTHER
AIR FILTER PRESSURE HIGH
LIMIT SWITCH
DEMAND
DEMAND RESPONSE
COMMAND
NOTES:
1) THE CONTRACTOR SHALL COMPLETE THE POINTS SCHEDULE AS SPECIFIED AND AS DESCRIBED IN THE POINTS SCHEDULE INSTRUCTIONS DRAWING.
2) UNIT MANUFACTURERS PROOFS AND SAFETIES: THE CONTRACTOR SHALL SHOW EACH PROOF AND SAFETY AS A SEPARATE ROW.
3) SYS-OCC: OVERRIDE OF SYS-OCC IS ACCOMPLISHED THROUGH THE SYSTEM SCHEDULER
4) ALARM CONDITION MARKED WITH AN ASTERISK SHALL BE ACTIVE ONLY WHEN THE SYSTEM IS IN OCCUPIED MODE AND HAS BEEN IN OCCUPIED MODE FOR MORE THAN: *=5 MINUTES, **=30 MINUTES
NODE: <DDC##>
NODE LOCATION: <___>
NODE ADDRESS: Domain = <___>, Subnet = <___>, Node = <___>
NODE ID: <___>
EMR-SS
X X X <___> <___> ~ X <___> <___> ~ ~ ~
AIRFLOW
OUTSIDE
OUTSIDE AIR DAMPEROA-D OPEN/CLOSED <___> BO ~
OUTSIDE AIR FLOW SETTING SEE SCHEDULE ~ ~<___> ~ ~ ~ ~
SA-D SUPPLY AIR DAMPER ~ OPEN/CLOSED <___> BO X X X <___> <___> ~ X <___> <___> ~ ~ ~ ~
OA-F
ON/OFF BI ~ X [~] <___> <___> ~ ~ ~ ~ ~ <___> ~EF-S ~
ON/OFF BO ~ ~ ~ <___> <___> ~ ~ <___> <___> ~ ~ ~ ~EF-SS ~
TYPICAL ENERGY RECOVERY UNIT:
EXHAUST FAN STATUS EXHAUST FAN PROOF FAILED
EXHAUST FAN START/STOP
ALM/NORMAL BI ~ ~ ~ <___> <___> ~ ~ ~ ~ DIRTY FILTER <___> <___> ~
AIR FILTER PRESSURE HIGH
LIMIT SWITCH
FLT-P-HL2
FLT-P-HL1 [0.45 WC]
[0.45 WC]
NOT TO SCALE
MI-603
ENERGY RECOVERY UNIT(ERV) POINTS LIST
P O
IN
T S L
IS
T
E N
E R
G Y R
E C
O V
E R
Y V
E N
T
IL
A T
O R
US Army Corps of Engineers
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
$FILEL$
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
$DATE$ $TIME$
S u b m it te d b y
C h e c k e d b y
D ra w n b y
D e s ig n e d b y
P L
O T D
A T
E
P L
O T S
C A
L E
F O
R T H
O O
D T
E X
A S
T
H A
IR
D
E F
E N
S E A
R T
IL
L E
R Y D
IV
IS
IO
N
P N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
T
A Y
L O
R S
T
F O
R T W
O R
T H T
X
S U
P P
L Y S
U P
P O
R T A
C T
IV
IT
Y W
A R
E H
O U
S E
S o li c it a ti o n N o
C o n tr a c t
N o
Is s u e D a te
E N
G
IN
E E
R
IN
G B
R A
N C
H
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G
NUMBER
SHEET
W
G -1
-B -0
C H
IE
F
M E
C H
A N
IC
A L S
E C
T
IO
N G
IL
B E
R T J
V A
L L
A P .E
A U
G U
S T
MI-604
W O
O D
A R
D P .E
G
W O
O D
A R
D P .E
K
W
IL
L
IA
M S P .E
EMERGENCY STOP SWITCH
DDC-##
EF-SS EF-S
EF
DDC
EA-D-C
NC
EXHAUST AIR
THE CONTRACTOR SHALL COMPLETE THE POINTS SCHEDULE AS SPECIFIED AND AS DESCRIBED IN THE POINTS SCHEDULE INSTRUCTIONS DRAWING.1)
NOTES:
SPACE AIR
EMERGENCY STOP SWITCH
DDC-##
EF-SS EF-S
EF
EXHAUST AIR
EA-D-C
NC
DDC
EMR-SS
EMR-SS
NODE: <DDC##>
NODE LOCATION: <___>
NODE ADDRESS: Domain = <___>, Subnet = <___>, Node = <___>
NODE ID: <___>
FUNCTION NAME DESCRIPTION
PROOFS &
SAFETIES
<UNIT MANUFACTURER’S
PROOF> (SEE NOTES)
<___> ALM/NORMAL < ~ > <BI> ~
<UNIT MANUFACTURER’S
SAFETIES> (SEE NOTES>
<___> ALM/NORMAL < ~ > <BI> ~
START/STOP ~ ~ < ~ > BI ~
OTHER POINTS
~ ~ < ~ > BI ~
REQ’D
HOA
TYPE
IO
NAME
nci/CPT
(WITH UNITS)
RANGE
(WITH UNITS)
SETTING
(SEE NOTES)
CONDITION
ALARM
LDP AND M&C DISPLAY OVERRIDES ALARMS
LDP
VIEW
REQ’D
M&C
SNVT
NAME
SNVT
TYPE
LDP
OVRD
REQ’D
M&C
OVRD
REQ’D
ALARM
PRIORITY
M&C
ROUTING
DISP
REQ’D
TREND
REQ’D
SNVT
NAME
SNVT
TYPE
~ ~ ~ ~ ~ ~ ~ ~ ~ ALM [info] [crit] [___]
~ X ~ <___> <___> ~ ~ <___> <___> ~ ~ ~
~ X ~ <___> <___> ~ ~ <___> <___> ~ ~ ~
EXHAUST FAN POINTS SCHEDULE
~ < ~ > AO ~ X X ~ <___> <___> ~ X <___> <___> ~ ~ ~
~ < ~ > BI ~ ~ ~ X ~ ~ ~ ~
EA-D-C
EMERGENCY STOP SWITCH
EXHAUST FAN DAMPER COMMAND 0-100% OPEN
ON/OFF ~ ~ ~ ~ ~EMR-SS
TO: DDC
NOT TO SCALEMI-604
NOT TO SCALEMI-604
& DAMPER
WALL LOUVER
P O
IN
T S L
IS
T
A N
D
E X
H A
U S
T F
A N H
V A
C C
O N
T R
O L S
DDC-##
CF-S
FAN
CIRCULATING
CF-SS
NOT TO SCALEMI-604
EMERGENCY STOP SWITCH
EMR-SS
TO: DDC
EF or CF-SS
EF or CF-S
FAN CONTROL SCHEMATIC (WAREHOUSE)
TYPICAL CEILING MOUNTED CIRCULATOR
EXHAUST/CIRCULATING
FAN START/STOP
EXHAUST /CIRCULATING
FAN STATUS
3 SPEED FAN
AND MANUAL / OFF CONTROL
OPERATE UNDER THERMOSTATIC CONTROL
REF-1,A,B,C, REF -2, A,B,C, REF-3,A,B,C
TYPICAL ROOF MOUNTED EXHAUST FAN CONTROL SCHEMATIC
NC
EA-D-C
DDC
WITH DAMPER
WALL MOUNTED LOUVER
SPACE AIR
AIR
OUTSIDE
DAMPER
REF’S ASSOCIATED
TO: DDC
EMERGENCY STOP SWITCH
DDC-##
EF-SS EF-S
EF
DDC
EA-D-C
NC
EXHAUST AIR
EMR-SS
NOT TO SCALEMI-604
& DAMPER
WALL LOUVER
TO: DDC
EF-2(A,B,&C) AND 3B (MECHANICAL ROOMS)
TYPICAL INLINE EXHAUST FAN CONTROL SCHEMATIC
EF-1(A,B,&C) (REST ROOMS)
TYPICAL INLINE EXHAUST FAN CONTROL SCHEMATIC
SPACE TEMPERATURE CONTROL
THE DDC HARDWARE SHALL CONTROL THE UNIT IN ACCORDANCE WITH ITS
(3) AUTO: WITH THE THERMOSTAT ON- OFF-AUTO SWITCH IN THE AUTO POSITION
AIR DAMPER.
THE DDC HARDWARE SHALL STOP THE EXHAUST FAN AND CLOSE THE OUTSIDE
(2) OFF: WITH THERMOSTAT ON-OFF-AUTO SWITCH IN THE OFF POSITION.
OUTSIDE AIR DAMPER.
THE DDC HARDWARE SHALL ENERGIZE THE EXHAUST FAN AND OPEN THE
(1) ON: WITH THE THERMOSTAT ON -OFF-AUTO SWITCH IN THE ON POSITION.
A. ON-OFF-AUTO SWITCH
POINTS SCHEDULE.
TO PROVIDE SNVT INPUTS AND OUTPUTSAS SPECIFIED AND SHOWN ON THE
INSTALL DDC HARDWARE TO PERFORM THIS SEQUENCE OF OPERATION AND
THERMOSTAT VENTILATION
MOUNTED THERMOSTAT
SET POINT OR AT THE OCCUPANT ADJUSTABLE SETPOINT VIA THE WALL
DAMPER TO MAINTAIN SPACE TEMPERATURE AT THE CONFIGURED
(1) THE DDC HARDWARE SHALL CYCLE THE EXHAUST FAN AND OUTSIDE AIR
B. SPACE TEMPERATURE CONTROL
GRILLE
EXHAUST
MOUNTED
THRU DUCT
SPACE AIR
GRILLE
EXHAUST
MOUNTED
THRU DUCT
SPACE AIR
RUNS CONTINOUSLY OPERATES BASED ON BUILDING OCCUPANY SCHEDULE
US Army Corps of Engineers
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
$FILEL$
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
$DATE$ $TIME$
S u b m it te d b y
C h e c k e d b y
D ra w n b y
D e s ig n e d b y
P L
O T D
A T
E
P L
O T S
C A
L E
F O
R T H
O O
D T
E X
A S
T
H A
IR
D
E F
E N
S E A
R T
IL
L E
R Y D
IV
IS
IO
N
P N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
T
A Y
L O
R S
T
F O
R T W
O R
T H T
X
S U
P P
L Y S
U P
P O
R T A
C T
IV
IT
Y W
A R
E H
O U
S E
S o li c it a ti o n N o
C o n tr a c t
N o
Is s u e D a te
E N
G
IN
E E
R
IN
G B
R A
N C
H
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G
NUMBER
SHEET
W
G -1
-B -0
C H
IE
F
M E
C H
A N
IC
A L S
E C
T
IO
N G
IL
B E
R T J
V A
L L
A P .E
A U
G U
S T
MI-605
W O
O D
A R
D P .E
G
W O
O D
A R
D P .E
K
W
IL
L
IA
M S P .E
P O
IN
T S L
IS
T
A N
D
U N
IT
H
E A
T E
R H
V A
C C
O N
T R
O L S
ALL MODES OF OPERATION:
THE UNIT SHALL BE CONTROLLED BY OFF-AUTO SWITCH AS PART OF THE UNIT
THERMOSTAT.
IN THE AUTO POSITION THE UNIT SHALL OPERATE VIA THE UNIT MOUNTED THERMOSTAT
TO MAINTAIN A SPACE TEMPERATURE OF 50 DEG. F. (ADJUSTABLE). THE SPACE
TEMPERATURE AND UNIT RUN TIME SHALL BE MONITORED AND TRENDED BY THE DDC
SYSTEM.
H
RETURN AIR SUPPLY AIR
DDC
SA-SSSA-S
DDC
THERMOSTAT
SF
NODE: <DDC##>
NODE LOCATION: <___>
NODE ADDRESS: Domain = <___>, Subnet = <___>, Node = <___> LDP AND M&C DISPLAY OVERRIDES ALARMS
NODE ID: <___>
LDP
VIEW
REQ’D
M&C
SNVT
NAME
SNVT
TYPE
LDP
OVRD
REQ’D
M&C
OVRD
REQ’D
ALARM CONDITION
(SEE NOTES)
ALARM
PRIORITY
M&C
ROUTINGFUNCTION NAME DESCRIPTION
SETTING
(WITH UNITS)
RANGE nci/CPT
NAME
IO
TYPE HOA REQ’D
DISP
REQ’D
TREND
REQ’D
SNVT
NAME
SNVT
TYPE
PROOFS &
SAFETIES
<___> <UNIT MANUFACTURER’S
PROOF> (SEE NOTES)
<___> ALM/NORMAL < ~ > <BI> ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ [___]
<___> <UNIT MANUFACTURER’S
SAFETIES> (SEE NOTES>
<___> ALM/NORMAL < ~ > <BI> ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ALM [info] [crit] [___]
START / STOP
OFF / AUTO UNIT OFF / AUTO SWITCH ~ ~ < ~ > BI ~ ~ [ ~ ] [ ~ ] <___> <___> ~ [ ~ ] <___> <___> ~ ~ ~
UNIT STATUS UNIT STATUS (SEE NOTES) ~ HVAC_HEAT/
HVAC_OFF
< ~ > NVO ~ [ ~ ] [ X ] [ ~ ] <___> HVAC_STATUS ~ ~ ~ ~ ~ ~ ~
ZONE
TEMPERATURE
CONTROL
ZN-T ZONE TEMPERATURE ** ~ <___> < ~ > AI ~ [ ~ ] X X <___> TEMP_P ~ ~ ~ ~ [info] [crit] [___]
ZN-T-SP ZONE TEMPERATURE
SETPOINT
55 DEG F
(ADJ)
< ~ > AI ~ [ ~ ] X [ ~ ] <___> <___> [ ~ ] X <___> <___> ~ ~ ~
SF-SS SUPPLY FAN START/STOP ~ [OFF/LO/MED/HI] < ~ > BO ~ [ ~ ] X [ ~ ] <___> <___> ~ ~ ~ ~ ~ ~ ~
HEATING VALVE PID LOOP
SETTINGS
NOTES:
1)THE CONTRACTOR SHALL COMPLETE THE POINTS SCHEDULE AS SPECIFIED AND AS DESCRIBED IN THE POINTS SCHEDULE INSTRUCTIONS DRAWING.
2)UNIT MANUFACTURERS PROOFS AND SAFETIES: THE CONTRACTOR SHALL SHOW EACH PROOF AND SAFETY AS A SEPARATE ROW.
3)SYS-OCC: AS DESCRIBED IN THE POINTS SCHEDULE INSTRUCTIONS, OVERRIDE OF SYS-OCC IS ACCOMPLISHED THROUGH THE SYSTEM SCHEDULER.
4) ALARM CONDITIONS MARKED WITH A DOUBLE ASTERISK (**) SHALL BE ACTIVE ONLY WHEN THE SYSTEM IS IN OCCUPIED MODE AND HAS BEEN IN OCCUPIED MODE FOR MORE THAN 30 MINUTES.
5) UNIT STATUS: SERVES AS A MONITORED POINT AT THE M&C SOFTWARE (FRONT-END) AND AS A HEATING/COOLING REQUEST TO THE BOILER, AND/OR CHILLER SERVING THIS SYSTEM.
UNIT HEATER SEQUENCE OF OPERATION
UNIT HEATER
(WITH UNITS)
OR BELOW 68 DEG F
** ZN-T MORE THAN 77 DEG F
E
NOT TO SCALE
TYPICAL UNIT HEATER SHCEMATIC
MI-605
IN THE OFF POSITION THE UNIT SHALL BE DE- ENERGIZED.
ON MODE: FAN RUNS AND ELECTRIC HEATING COIL OR GAS FIRED HEATING IS OPERATING.
FOR ELECTRIC OR GAS HEATING EQUIPMENT: EUH’S, INFRA RED HEATING UNITS AND GAS FIRED UNIT HEATERS, IRH’S AND GFUH’S
NOT TO SCALEMI-605
TYPICAL UNIT HEATER POINTS LIST
US Army Corps of Engineers
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
$FILEL$
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
$DATE$ $TIME$
S u b m it te d b y
C h e c k e d b y
D ra w n b y
D e s ig n e d b y
P L
O T D
A T
E
P L
O T S
C A
L E
F O
R T H
O O
D T
E X
A S
T
H A
IR
D
E F
E N
S E A
R T
IL
L E
R Y D
IV
IS
IO
N
P N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
T
A Y
L O
R S
T
F O
R T W
O R
T H T
X
S U
P P
L Y S
U P
P O
R T A
C T
IV
IT
Y W
A R
E H
O U
S E
S o li c it a ti o n N o
C o n tr a c t
N o
Is s u e D a te
E N
G
IN
E E
R
IN
G B
R A
N C
H
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G
NUMBER
SHEET
W
G -1
-B -0
C H
IE
F
M E
C H
A N
IC
A L S
E C
T
IO
N G
IL
B E
R T J
V A
L L
A P .E
A U
G U
S T
MI-606
W O
O D
A R
D P .E
G
W O
O D
A R
D P .E
K
W
IL
L
IA
M S P .E
ALL MODES OF OPERATION:
THE UNIT SHALL BE CONTROLLED BY OFF-ON-AUTO SWITCH AS PART OF THE UNIT THERMOSTAT. IN THE AUTO POSITION THE UNIT SHALL OPERATE PER
MANUFACTURER’S CONTROLS TO MAINTAIN THE SPACE AT 72 DEG. F. (ADJUSTABLE). IN THE ON POSITION THE UNIT SHALL BE ENABLED AND IN THE OFF
POSITION THE UNIT SHALL BE DISABLED AND NOT RUN. THE SPACE TEMPERATURE AND UNIT RUN TIME SHALL BE MONITORED AND TRENDED BY THE
DDC SYSTEM.
NODE: <DDC##>
NODE LOCATION: <___>
NODE ADDRESS: Domain = <___>, Subnet = <___>, Node = <___>
LDP AND M&C DISPLAY OVERRIDES ALARMS
NODE ID: <___>
LDP
VIEW
REQ’D
M&C
SNVT
NAME
SNVT
TYPE
LDP
OVRD
REQ’D
M&C
OVRD
REQ’D
ALARM CONDITION
(SEE
NOTES)
ALARM
PRIORITY
M&C
ROUTINGFUNCTION NAME DESCRIPTION
SETTING
(WITH UNITS)
RANGE
(WITH
UNITS)
nci/CPT
NAME
IO
TYPE HOA REQ’D
DISP
REQ’D
TREND
REQ’D
SNVT
NAME
SNVT
TYPE
PROOFS &
SAFETIES
<___> <UNIT MANUFACTURER’S
PROOF> (SEE NOTES)
<___> ALM/NORMAL < ~ > <BI> ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ [___]
<___> <UNIT MANUFACTURER’S
SAFETIES> (SEE NOTES>
<___> ALM/NORMAL < ~ > <BI> ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ALM [info] [crit] [___]
RST-BUT SYSTEM RESET BUTTON ~ ~ <___> <BI> ~ [ ~ ] [ ~ ] [ ~ ] <___> <___> [ ~~~~ ] [ ~~~~ ] <~~~~ > <~~~~ >
START/STOP
<___> OFF-COOL SWITCH INPUT ~ OFF/COOL/
<EMERG>
SF-ON/AUTO SUPPLY FAN ON/AUTO SWITCH ~ ON/AUTO <___> BI ~ ~ ~ ~ <___> <___> ~ ~ ~ ~ ~ ~ ~
UNIT STATUS UNIT STATUS (SEE NOTES) ~ HVAC_COOL/
HVAC_OFF
<___> NVO ~ ~ X ~ <___> HVAC_STATUS ~ ~ ~ ~
ZONE
TEMPERATURE
CONTROL
ZN-T ZONE TEMPERATURE ~ <___> <___> AI ~ X X X <___> TEMP_P ~ ~ ~ ~ ** ZN-T MORE THAN 77 DEG F
OR BELOW 68 DEG F
info ~
ZN-T-SP ZONE TEMPERATURE
SETPOINT
OCCUPANT
ADJUSTABLE
[68-77 DEG F] <___> AI ~ X X X <___> <___> X X <___> <___> ~ ~ ~
SF-SS SUPPLY FAN START/STOP
COMMAND
~ ON/OFF <___> BO [~] [ ~ ] [ ~ ] [ ~ ] <___> <___> [ ~ ] X <___> <___> ~ ~ ~
COMP-SS COMPRESSOR (PKG UNIT)
START/STOP
~ ON/OFF <___> BO [~] [ ~ ] [ ~ ] [ ~ ] <___> <___> [ ~ ] X <___> <___> ~ ~ ~
Notes:
1)THE CONTRACTOR SHALL COMPLETE THE POINTS SCHEDULE AS SPECIFIED AND AS DESCRIBED IN THE POINTS SCHEDULE INSTRUCTIONS DRAWING.
2)UNIT MANUFACTURERS PROOFS AND SAFETIES: THE CONTRACTOR SHALL SHOW EACH PROOF AND SAFETY AS A SEPARATE ROW.
3) UNIT STATUS: SERVES AS A MONITORED POINT AT THE M&C SOFTWARE (FRONT-END) AND AS A HEATING/COOLING REQUEST TO THE BOILER, AND/OR CHILLER SERVING THIS SYSTEM.
COMPUTER ROOM AIR CONDITIONING UNIT SEQUENCE OF OPERATION
COMPUTER ROOM AIR CONDITIONING UNIT
P O
IN
T S L
IS
T
A N
D
C R
A C U
N
IT
H
V A
C C
O N
T R
O L S
NOT TO SCALE
POINTS LIST (CRAC-1)
COMPUTER ROOM AIR CONDITIONING
MI-606
US Army Corps of Engineers
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
$FILEL$
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
$DATE$ $TIME$
S u b m it te d b y
C h e c k e d b y
D ra w n b y
D e s ig n e d b y
P L
O T D
A T
E
P L
O T S
C A
L E
F O
R T H
O O
D T
E X
A S
T
H A
IR
D
E F
E N
S E A
R T
IL
L E
R Y D
IV
IS
IO
N
P N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
T
A Y
L O
R S
T
F O
R T W
O R
T H T
X
S U
P P
L Y S
U P
P O
R T A
C T
IV
IT
Y W
A R
E H
O U
S E
S o li c it a ti o n N o
C o n tr a c t
N o
Is s u e D a te
E N
G
IN
E E
R
IN
G B
R A
N C
H
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G
NUMBER
SHEET
W
G -1
-B -0
C H
IE
F
M E
C H
A N
IC
A L S
E C
T
IO
N G
IL
B E
R T J
V A
L L
A P .E
A U
G U
S T
MI-607
W O
O D
A R
D P .E
G
W O
O D
A R
D P .E
K
W
IL
L
IA
M S P
METERS
PRIMARY WATER
METER
PRIMARY WATER METER ~ <___> BI ~ X X X <___> <___> ~ ~ ~ ~ ~
SUB WATER
METER(S)
SUB WATER METERS ~ <___> BI ~ X X X <___> <___> ~ ~ ~ ~ ~
SUB ELECT.
METER(S)
SUB ELECTRICAL METERS ~ <___> ~ X X <___> <___> ~ ~ ~ ~
DOM HOT WATER
METER
DOMESTIC HOT WATER
METER
~ <___> BI ~ X X X <___> <___> ~ ~ ~ ~ ~
Notes:
1) THE CONTRACTOR SHALL PROVIDE CONTROL POINTS FOR ALL PRIMARY AND SUB METERS
NODE: <DDC##>
NODE LOCATION: <___>
NODE ADDRESS: Domain = <___>, Subnet = <___>, Node = <___> LDP AND M&C DISPLAY OVERRIDES ALARMS
NODE ID: <___>
LDP
VIEW
REQ’D
M&C
SNVT
NAME
SNVT
TYPE
LDP
OVRD
REQ’D
M&C
OVRD
REQ’D
ALARM CONDITION
(SEE NOTES)
ALARM
PRIORITY
M&C
ROUTINGFUNCTION NAME DESCRIPTION
SETTING
(WITH UNITS)
RANGE
(WITH UNITS)
nci/CPT
NAME
IO
TYPE HOA REQ’D
DISP
REQ’D
TREND
REQ’D
SNVT
NAME
SNVT
TYPE
PRIMARY ELECT.
METER
PRIMARY ELECTRICAL
METER
~ <___> ~ X X <___> <___> ~ ~ ~ ~~
BI
BI
X
X
METER POINTS
NODE: <DDC##>
NODE LOCATION: <___>
NODE ADDRESS: Domain = <___>, Subnet = <___>, Node = <___> LDP AND M&C DISPLAY OVERRIDES ALARMS
NODE ID: <___>
LDP
VIEW
REQ’D
M&C
SNVT
NAME
SNVT
TYPE
LDP
OVRD
REQ’D
M&C
OVRD
REQ’D
ALARM CONDITION
(SEE NOTES)
ALARM
PRIORITY
M&C
ROUTINGFUNCTION NAME DESCRIPTION
SETTING
(WITH UNITS)
RANGE
(WITH UNITS)
nci/CPT
NAME
IO
TYPE HOA REQ’D
DISP
REQ’D
TREND
REQ’D
SNVT
NAME
SNVT
TYPE
PROOFS
SAFETIES
ON/OFF <___> BI ~ X X ~ <___> <___> ~ ~ ~ ~ info ~
~ ON/OFF <___> BO ~ X X ~ <___> <___> ~ X <___> <___> ~ ~ ~START /
STOP
WH-ESS
SHUTDOWN SWITCH
~ ON/OFF BI ~ ~ ~ ~ ~ X ~ ~ X<___> ~ ~ ~ ~
DOMESTIC WATER HEATER LOOP
DOMESTIC HOT WATER SEQUENCE OF OPERATION
ALL MODES OF OPERATION:
THE DOMESTIC HOT WATER SYSTEM SHALL OPERATE THRU THE DDC
WATER HEATER CONTROLLER. THE DDC WATER HEATER CONTROLLER SHALL
HEATER OPERATING STATUS AND ALARMS BY THE DDC SYSTEM. THE DDC
WATER HEATER CONTROLLER SHALL ENABLE AND OPERATE THE WATER
TEMPERATURE LIMIT ALARM:
THE DDC SYSTEM SHALL INITIATE TEMPERATURE ALARMS FOR THE
DOMESTIC HOT WATER SYSTEM WHEN THE TEMPERATURE RISES ABOVE
THE HIGH LIMIT SHOWN IN THE POINTS LIST.
EMERGENCY SHUTDOWN
WH- 1 ##
DDC
WH- 1- SS
WH- 1- S
NOTE1: CONTRACTOR SHALL AFFIX PERMANENT TAGS/LABELS TO ALL DEVICES AS SPECIFIED
NOTE2: CONTRACTOR SHALL LABEL ALL DDC I/O SIGNAL LINES: 4-20 MA, VDC, OR DATA
NOTE3: CONTRACTOR SHALL SHOW A UNIQUE IDENTIFIER FOR EACH DEVICE, WHERE MULTIPLE
IDENTICAL DEVICES ARE SHOWN (FOR EXAMPLE: DDC CONTROLLER, OA SENSOR, OR UP
TRANSDUCER) EACH SHALL BE SEQUENTIALLY NUMBERED. WHERE SEPARATE DDC
CONTROLLER BUBBLES ARE USED TO REPRESENT/SHOW A COMMON (OR SINGLE) IDENTIFIERS
SHALL BE CONSISTENT BETWEEN DRAWINGS.
NOTE4: CONTRACTOR SHALL UNIQUELY NUMBER ALL ANSI 709.1 DEVICES. THIS NUMBERING SHALL BE
CONSISTENT BETWEEN ALL DRAWINGS.
RST-BUT
SAFETY RESET
ELECTRIC
REFER TO ELECTRICAL
DRAWINGS FOR METER
QUANTITIES AND LOCATIONS
METER
DOMESTIC HOT WATER
BLDG PRIMARY DOMESTIC WATER
WH-ESS
STOP SWITCH
TO: DDC
TO SYSTEM
DCW
THE WATER HEATER SHALL CLOSE ALL GAS VALVES AND POWER DOWN WHEN THE
UTILIZE LONWORKS COMMUNICATION INTERFACE FOR MONITORING WATER
HEATER TO MAINTAIN DOMESTIC WATER STORAGE TANK TEMPERATURES.
THE WATER HEATERS SHALL OPERATE PER THE MANUFACTURER�S PACKAGED
BURNERS AND NUMBER OF WATER HEATERS TO MAINTAIN A LEAVING WATER
TEMPERATURE OF 145 DEG. F. (ADJUSTABLE) ALL WATER HEATER SAFETIES
AND ALARMS SHALL BE MONITORED BY THE DDC WATER HEATER CONTROLLER.
CONTROLS. THE PACKAGED CONTROLS SHALL STAGE THE WATER HEATERS
EMERGENCY WATER HEATER GAS SHUTOFF SWITCH IS ACTIVATED.
HOT WATER GAS
WATER HEATER EMERGENCY
HOT WATER HEATER FAILED
THE CONTRACTOR SHALL COMPLETE THE POINTS SCHEDULE AS SPECIFIED AND AS DESCRIBED IN THE POINTS SCHEDULE INSTRUCTIONS DRAWING.
UNIT MANUFACTURERS PROOFS AND SAFETIES: THE CONTRACTOR SHALL SHOW EACH PROOF AND SAFETY AS A SEPARATE ROW.
1)
2)
P O
IN
T S L
IS
T
A N
D
U T
IL
IT
Y S
U B M
E T
E R
S
NOT TO SCALE
DOMESTIC HOT WATER CONTROLS
MI-607
US Army Corps of Engineers
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
$FILEL$
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
$DATE$ $TIME$
S u b m it te d b y
C h e c k e d b y
D ra w n b y
D e s ig n e d b y
P L
O T D
A T
E
P L
O T S
C A
L E
F O
R T H
O O
D T
E X
A S
T
H A
IR
D
E F
E N
S E A
R T
IL
L E
R Y D
IV
IS
IO
N
P N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
T
A Y
L O
R S
T
F O
R T W
O R
T H T
X
S U
P P
L Y S
U P
P O
R T A
C T
IV
IT
Y W
A R
E H
O U
S E
S o li c it a ti o n N o
C o n tr a c t
N o
Is s u e D a te
E N
G
IN
E E
R
IN
G B
R A
N C
H
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G
NUMBER
SHEET
W
G -1
-B -0
C H
IE
F
M E
C H
A N
IC
A L S
E C
T
IO
N G
IL
B E
R T J
V A
L L
A P .E
A U
G U
S T
MI-608
W O
O D
A R
D P .E
G
W O
O D
A R
D P .E
K
W
IL
L
IA
M S P
SWITCH
SHUTOFF
EMERGENCY SMK-01
CONTACT
SA-P-HL
CONTACT
REMOTE SAFETY OVERRIDE
(FAP INTERFACE)
FAP
SAFETIES
HAND
OFF
AUTO
START/STOP
SF-SS
DDC
DDC
SF-S
STATUS (ON/OFF)
SUPPLY FAN
CONTRACTOR WIRING MAY DIFFER
NOTE 1: THIS IS A FUNCTIONAL REPRESENTATION.
FR - 01
LOC: ROOM 123
SWITCH
SHUTOFF
EMERGENCY SMK-01
CONTACT
SA-P-HL
CONTACT
REMOTE SAFETY OVERRIDE
(FAP INTERFACE)
FAP
SAFETIES
HAND
OFF
AUTO
START/STOP
SF-SS
DDC
DDC
SF-S
STATUS (ON/OFF)
SUPPLY FAN
CONTRACTOR WIRING MAY DIFFER
NOTE 1: THIS IS A FUNCTIONAL REPRESENTATION.
FR - 01
LOC: WAREHOUSE
P A
H U A
N D E
R V
C O
N T
R O
L L
A D
D E
R D
IA
G R
A M
S
NOT TO SCALE
MI-608 NOT TO SCALE
MI-608
(PAHU-1A,1B, & 1C) LADDER DIAGRAM
PACKAGED AIR HANDLING UNIT
(ERV-1A, 1B, & 1C) LADDER DIAGRAM
ENERGY RECOVERY VENTILATOR
US Army Corps of Engineers
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
$FILEL$
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
$DATE$ $TIME$
S u b m it te d b y
C h e c k e d b y
D ra w n b y
D e s ig n e d b y
P L
O T D
A T
E
P L
O T S
C A
L E
F O
R T H
O O
D T
E X
A S
T
H A
IR
D
E F
E N
S E A
R T
IL
L E
R Y D
IV
IS
IO
N
P N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
T
A Y
L O
R S
T
F O
R T W
O R
T H T
X
S U
P P
L Y S
U P
P O
R T A
C T
IV
IT
Y W
A R
E H
O U
S E
S o li c it a ti o n N o
C o n tr a c t
N o
Is s u e D a te
E N
G
IN
E E
R
IN
G B
R A
N C
H
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G
NUMBER
SHEET
W
G -1
-B -0
C H
IE
F
M E
C H
A N
IC
A L S
E C
T
IO
N G
IL
B E
R T J
V A
L L
A P .E
A U
G U
S T
MI-609
W O
O D
A R
D P .E
G
W O
O D
A R
D P .E
K
W
IL
L
IA
M S P .E
H V
A C C
O N
T R
O L S
D E
M A
N D R
E S
P O
N S
E
HVAC EQUIPMENT
DDC SYSTEM WILL SEND A SIGNAL (DR-HVAC) TO HVAC EQUIPMENT AND THE HVAC EQUIPMENT WILL ENTER DEMAND
NORMAL OPERATION. NO MANUAL RESET SHALL BE REQUIRED.
PAHU’’s EQUIPMENT
DEMAND RESPONSE SEQUENSE OF OPERATIONS
LDP AND M&C DISPLAY OVERRIDES ALARMS
LDP
VIEW
REQ’D
M&C
SNVT
NAME
SNVT
TYPE
LDP
OVRD
REQ’D
M&C
OVRD
REQ’D
ALARM CONDITION
(SEE NOTES)
ALARM
PRIORITY
M&C
ROUTING
FUNCTION NAME DESCRIPTION
SETTING
(WITH UNITS)
RANGE (WITH
UNITS)
nci/CPT
NAME
IO
TYPE HOA REQ’D
DISP
REQ’D
TREND
REQ’D
SNVT
NAME
SNVT
TYPE
ACTIVATE /
DEACTIVATE
DR-A
DEMAND RESPONSE ACTIVATE
FROM UMCS
~ ~ ~ <BI> ~ ~ X X <___> <___> ~ X X <___> DEMAND RESPONSE ACTIVE X <___>
DR-DA
DEMAND RESPONSE
DEACTIVATE FROM UMCS
~ ~ ~ <BI> ~ ~ X X <___> <___> ~ X X <___> ~ X <___>
SYSTEMS
DEMAND RESPONSE PAHU
SYSTEMS
~ ~ ~ <BI> ~ ~ X X <___> <___> ~ X X <___> X <___>
NOTES:
1) THE CONTRACTOR SHALL COMPLETE THE POINTS SCHEDULE AS SPECIFIED AND AS DESCRIBED IN THE POINTS SCHEDULE INSTRUCTIONS DRAWING.
NODE: <DDC##>
NODE LOCATION: <___>
NODE ADDRESS: Domain = <___>, Subnet = <___>, Node = <___>
NODE ID: <___>
DEMAND RESPONSE
DEMAND RESPONSE MODE: THE BUILDING SHALL ENTER DEMAND RESPONSE MODE ONCE A SIGNAL FROM THE UMCS
SHALL REMAIN IN DEMAND RESPONSE MODE UNTIL INSTRUCTED BY THE UMCS TO DEACTIVATE DEMAND RESPONSE MODE.
ONCE THE DEMAND RESPONSE SIGNAL FROM THE UMCS IS REMOVED THE DDC SHALL SIGNAL ALL EFFECTED SYSTEMS TO
MANUAL RESET SHALL BE REQUIRED.
DEACTIVATE DEMAND RESPONSE MODE AND ALL EQUIPMENT SHALL AUTOMATICALLY RETURN TO NORMAL OPERATION. NO
~ ~ ~ <BI> ~
&1C
DR-PAHU-1A, 1B,
DR-IRH’s & GFUH’s
EUH’s WAREHOUSE HEATING SYSTEMS
DR-ERV’s
ENERGY RECOVERY VENTILATORS
WAREHOUSE EXHAUST FANS
~ ~ ~ <BI> ~
~ ~ ~ <BI> ~
~ X X <___> <___> ~ X X <___>
~ X X <___> <___> ~ X X <___>
~ X X <___> <___> ~ X X <___>
DEMAND RESPONSE - PAHU’s
WARE HOUSE EXHAUST FANS
DEMAND RESPONSE -
HEATING SYSTEMS
DEMAND RESPONSE - WAREHOUSEDEMAND RESPONSE
DEMAND RESPONSE
DEMAND RESPONSE
VENTILATORS
DEMAND RESPONSE - ENERGY RECOVERY
X <___>
X <___>
X <___>
2)
IS SENT TO THE BUILDING DDC SYSTEM INSTRUCTING THE FACILITY TO ACTIVATE THE DEMAND RESPONSE MODE. THE BUILDING
AND ALL WAREHOUSE EXHAUST FANS.
THE TERM HVAC EQUIPMENT SHALL MEAN: ALL PAHU’s, ALL WARE HOUSE HEATING EQUIPMENT, ALL ENERGY RECOVERY VENTILATORS
WAREHOUSE HEATING EQUIPMENT
COOLING MODE: NA
ENERGY RECOVERY VENTILATORS
COOLING MODE: NA
HEATING MODE: EQUIPMENT SHALL RESET THE HEATING SET POINTS DOWN 5 DEG F. (ADJUSTABLE).
HEATING MODE: EQUIPMENT SHALL RESET THE HEATING SET POINTS DOWN 5 DEG F. (ADJUSTABLE).
HEATING MODE: EQUIPMENT SHALL BE DE-ENERGIZED.
HEATING MODE: EQUIPMENT SHALL BE DE-ENERGIZED.
WAREHOUSE EXHAUST FANS
COOLING MODE: EQUIPMENT SHALL BE DE-ENERGIZED
3C & F-1A,1B, 1C
2A, 2B, 2C & 3A, 3B
DR-REF-1A, 1B, 1C
FUNCTION.
WHEN DEMAND RESPONSE PERIOD IS TERMINATED ALL PAHU’S SHALL RESUME NORMAL OPERATIONAL
3. PAHU-1C SHALL BE DEACTIVATED FOR 15 MINUTES PAHU-1B AND 1A SHALL REMAIN ENERGIZED.
2. PAHU-1B SHALL BE DEACTIVATED FOR 15 MINUTES PAHU-1A AND 1C SHALL REMAIN ENERGIZED.
1. PAHU-1A SHALL BE DEACTIVATED FOR 15 MINUTES PAHU-1B AND 1C SHALL REMAIN ENERGIZED.
DEMAND RESPONSE PERIOD.
COOLING MODE: EQUIPMENT (PAHU-1A, 1B AND 1C ) SHALL DE-ENERGIZED ON A ROTATING BASIS DURING THE LENGHT OF THE
RESPONSE MODE. ONCE THE DDC SIGNAL (DR-HVAC) IS REMOVED THE HVAC SYSTEM SHALL AUTOMATICALLY RETURN TO
US Army Corps of Engineers
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
$FILEL$
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
$DATE$ $TIME$
S u b m it te d b y
C h e c k e d b y
D ra w n b y
D e s ig n e d b y
P L
O T D
A T
E
P L
O T S
C A
L E
F O
R T H
O O
D T
E X
A S
T
H A
IR
D
E F
E N
S E A
R T
IL
L E
R Y D
IV
IS
IO
N
P N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
T
A Y
L O
R S
T
F O
R T W
O R
T H T
X
S U
P P
L Y S
U P
P O
R T A
C T
IV
IT
Y W
A R
E H
O U
S E
S o li c it a ti o n N o
C o n tr a c t
N o
Is s u e D a te
E N
G
IN
E E
R
IN
G B
R A
N C
H
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G
NUMBER
SHEET
W
G -1
-B -0
C H
IE
F
M E
C H
A N
IC
A L S
E C
T
IO
N G
IL
B E
R T J
V A
L L
A P .E
A U
G U
S T
ES001
X T
E R
IO
R E
L E
C T
R
IC
A L L
E G
E N
D
Fort Worth District
US Army Corps of Engineers
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
$FILEL$
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
$DATE$ $TIME$
S u b m it te d b y
C h e c k e d b y
D ra w n b y
D e s ig n e d b y
P L
O T D
A T
E
P L
O T S
C A
L E
F O
R T H
O O
D T
E X
A S
T
H A
IR
D
E F
E N
S E A
R T
IL
L E
R Y D
IV
IS
IO
N
P N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
T
A Y
L O
R S
T
F O
R T W
O R
T H T
X
S U
P P
L Y S
U P
P O
R T A
C T
IV
IT
Y W
A R
E H
O U
S E
S o li c it a ti o n N o
C o n tr a c t
N o
Is s u e D a te
G
C H
O A
T E
G
C H
O A
T E
E N
G
IN
E E
R
IN
G B
R A
N C
H
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G
NUMBER
SHEET
D
B R
O W
N P .E
C H
IE
F E
L E
C T
R
IC
A L S
E C
T
IO
N D
A R
E N A
B R
O W
N P .E
W
G -1
-B -0
J U
N E
EE
P
H
CC
E
P
H
C
1 A
E
C
Ex
Cx
Ex
ES ES ES
x x
S
XXX.XX
E Ex Ex
A
PAD-MOUNTED SWITCH.
SINGLE MODE FIBER OPTIC CABLE
UNDERGROUND COMMUNICATIONS.
POLE. NUMBERS INDICATE HEIGHT AND CLASS OF POLE.
PAD MOUNT TRANSFORMER. NUMBER INDICATES KVA RATING
ELECTRICAL MANHOLE
COMMUNICATIONS MANHOLE
PULLBOX.
HANDHOLE.
TOP OF ELEVATION FOR MANHOLES AND HANDHOLES
DESCRIPTION
UNDERGROUND PRIMARY.
OVERHEAD PRIMARY.
UNDERGROUND SECONDARY.
ELECTRICAL EXTERIOR LEGEND
SYMBOL
NEW
EXISTING TO
REMAIN
EXISTING TO
BE REMOVED
APPEAR ON THE OTHER ELECTRICAL DRAWINGS.
NOT ALL SYMBOLS SHOWN ON THIS SHEET MAY
P
H
SMFOC
Cx
225 225
"3" INDICATES POLE CLASS.
"40" INDICATES POLE HEIGHT IN FEET.
"A" INDICATES POLE TYPE IN DETAIL SHEET.
"1" INDICATES POLE NO.
POLE IDENTIFICATION SYMBOL.
POLE MOUNT TRANSFORMER. NUMBER INDICATES KVA RATING10
of Engineers
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
$FILEL$
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
$DATE$ $TIME$
S u b m it te d b y
C h e c k e d b y
D ra w n b y
D e s ig n e d b y
P L
O T D
A T
E
P L
O T S
C A
L E
F O
R T H
O O
D T
E X
A S
T
H A
IR
D
E F
E N
S E A
R T
IL
L E
R Y D
IV
IS
IO
N
P N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
T
A Y
L O
R S
T
F O
R T W
O R
T H T
X
S U
P P
L Y S
U P
P O
R T A
C T
IV
IT
Y W
A R
E H
O U
S E
S o li c it a ti o n N o
C o n tr a c t
N o
Is s u e D a te
G
C H
O A
T E
G
C H
O A
T E
E N
G
IN
E E
R
IN
G B
R A
N C
H
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G
NUMBER
SHEET
D
B R
O W
N P .E
C H
IE
F E
L E
C T
R
IC
A L S
E C
T
IO
N D
A R
E N A
B R
O W
N P .E
W
G -1
-B -0
J U
N E
W
W
W
W
G
W
MAIN ROAD
A C
C E
S S R
O A
D
ORGANIZATIONAL VEHICLE TRAIL "A"
ORGANIZATIONAL VEHICLE TRAIL "A"ORGANIZATIONAL VEHICLE TRAIL "A"
MAIN ROAD
A C
C E
S S R
O A
D
ORGANIZATIONAL VEHICLE TRAIL "A"
ORGANIZATIONAL VEHICLE TRAIL "A"ORGANIZATIONAL VEHICLE TRAIL "A"
TEDESCO ROAD
(G R
A V
E L
U N
P A
V E
D R
O A
D
W
W
W
W
CCCC
C
C
C
C C
C
C
TEDESCOWAY
C
H
C
0 602060
SCALE: 1" = 60'-0"
ES101
T
E R
IO
R E
L E
C T
R
IC
A L P
L A
GENERAL SHEET NOTES SHEET KEYNOTES
T
H A
D A S
S A W
A R
E H
O U
S E
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
Fort Worth District
SEE SHEET EP601 FOR TRANSFORMER'S SIZE.
DETAILS.
TO COVERED HARDSTAND. SEE SHEET EP104 & EL104 FOR
C) SECOND, THIRD AND FOURTH INNER DUCT FOR SPARE.
LIGHTS AT COVERED HARDSTAND, CIRCUIT H1C-28
B) SECOND INNER DUCT: 3#10 & 1#10G IN 1"C FOR
RECEPTACLE AT COVERED HARDSTAND, CIRCUIT L2C-5.
A) FIRST INNER DUCT: 3#10 & 1#10G IN 1"C FOR
1-4" CONCRETE ENCASED DUCTS WITH 4-1" INNER DUCT:
C) THIRD AND FOURTH INNER DUCT FOR SPARE.
LIGHTS AT COVERED HARDSTAND, CIRCUIT H1B-28
B) SECOND INNER DUCT: 3#10 & 1#10G IN 1"C FOR
RECEPTACLE AT COVERED HARDSTAND, CIRCUIT L2B-5.
A) FIRST INNER DUCT: 3#10 & 1#10G IN 1"C FOR
1-4" CONCRETE ENCASED DUCTS WITH 4-1" INNER DUCT:
C) THIRD AND FOURTH INNER DUCT FOR SPARE.
LIGHTS AT COVERED HARDSTAND, CIRCUIT H1A-28
B) SECOND INNER DUCT: 3#10 & 1#10G IN 1"C FOR
RECEPTACLE AT COVERED HARDSTAND, CIRCUIT L2A-5.
A) FIRST INNER DUCT: 3#10 & 1#10G IN 1"C FOR
1-4" CONCRETE ENCASED DUCTS WITH 4-1" INNER DUCT:
NOT USED
NOT USED.
TO MAIN DISTRIBUTION PANEL IN ELECTRICAL RM.
B) THIRD DUCT FOR SPARE.
TRANSFORMER SECONDARY CONDUCTORS.
A) FIRST & SECOND DUCT: SEE EP601 FOR INFORMATION OF
3-4" CONCRETE ENCASED DUCTS:
B) SECOND DUCT FOR SPARE.
A) FIRST DUCT WITH 3 #1-15KV AND 1 #2/0G-600V.
2-4" CONCRETE ENCASED DUCTS:
CONNECT TO THE EXISTING LOOP-FED TRANSFORMER.
MANHOLE/HANDHOLE/TRANSFORMER.
PROVIDED COORDINATE IS AT THE CENTER POINT OF THE
LIGHTING.
MOUNTED TRANSFORMER TO ALL POLE MOUNTED
CONDUCTOR, HANDHOLES FROM A DEDICATED POLE
FIXTURES, POLE BASE AND NECESSARY CONDUIT,
POLE MOUNTED LIGHT FIXTURES, LIGHT POLES, LIGHT
DEDICATE PAD MOUNTED TRANSFORMER TO SERVICE
SECURITY FENCE). THIS WORK ITEM SHALL INCLUDE A
B) ALL POLE MOUNTED LIGHTING (INSIDE AND OUTSIDE THE
EQUIPMENT (PANEL MDP).
SECONDARY SERVICE AT THE SERVICE ENTRANCE
SERVICE TO THE BUILDING AND TERMINATE THE
-MOUNTED TRANSFORMER AND PAD, SECONDARY
A) INSTALLING ALL NEW PRIMARY DISTRIBUTION, PAD
SUBCONTRACTOR, IS RESPONSIBLE FOR:
FEET FROM THE BUILDING. DOMINION ENERGY, AS A
THE SERVICE ENTRANCE EQUIPMENT TO A POSITION FIVE-
THE GENERAL CONTRACTOR IS TO PROVIDE CONDUIT FROM
DOMINION POWER FOR COORDINATION PURPOSE.
(KEVIN.M.MANN@DOM.COM) IS THE POINT CONTACT AT
UNDER THIS CONTRACT. MR. KEVIN MANN
POWER TO ADAPT SCHEDULING AND PERFORMING THE WORK
THE CONTRACTOR SHALL COORDINATE WITH DOMINION
SUBCONTRACTOR, TO PERFORM ALL ASSOCIATED WORKS.
POWER. CONTRACTOR SHALL ENGAGE DOMINION POWER, AS
EXTERIOR ELECTRICAL HAS BEEN PRIVATIZED TO DOMINION
TRAFFIC AREAS SHALL BE DIRECTED BURIES.
CONCRETE ENCASED. ALL NEW DUCTS IN NON-VEHICULAR
ALL NEW DUCTS IN VEHICULAR TRAFFIC AREAS SHALL BE
PROVIDE PULL WIRE FOR SPARE CONDUIT.
SEE SHEET EP601-EP606 FOR PANEL SCHEDULES.
PANEL H2, L3A, L3B, AND L3C.
SEE SHEET EP101-EP103 FOR EXACT MOUNTING LOCATION OF
SEE SHEET EL104 FOR LIGHTING AT COVERED HARDSTAND.
8.
7.
6.
5.
4.
3.
2.
1.
TEDESCOWAY
POWER (CONDUIT 5FT FROM BUILDING).
POINT OF DEMARCATION FOR DOMINION
E=3120549.44
N=10392134.42
E=973060.71
N=8244684.59
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
$FILEL$
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
$DATE$ $TIME$
S u b m it te d b y
C h e c k e d b y
D ra w n b y
D e s ig n e d b y
P L
O T D
A T
E
P L
O T S
C A
L E
F O
R T H
O O
D T
E X
A S
T
H A
IR
D
E F
E N
S E A
R T
IL
L E
R Y D
IV
IS
IO
N
P N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
T
A Y
L O
R S
T
F O
R T W
O R
T H T
X
S U
P P
L Y S
U P
P O
R T A
C T
IV
IT
Y W
A R
E H
O U
S E
S o li c it a ti o n N o
C o n tr a c t
N o
Is s u e D a te
G
C H
O A
T E
G
C H
O A
T E
E N
G
IN
E E
R
IN
G B
R A
N C
H
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G
NUMBER
SHEET
D
B R
O W
N P .E
C H
IE
F E
L E
C T
R
IC
A L S
E C
T
IO
N D
A R
E N A
B R
O W
N P .E
W
G -1
-B -0
A U
G U
S T
TEDESCOWAY
W A
R E
H O
U S
E T
H A
D A S
T T R R
TR
W A
R E
H O
U S
E T
H A
D A S
W
R E
H O
U S
E T
H A
D A S
W
D
B
B
COVERED HARDSTAND
COVERED HARDSTAND
MAIN ROAD
A C
C E
S S R
O A
D
ORGANIZATIONAL VEHICLE TRAIL "A"
ORGANIZATIONAL VEHICLE TRAIL "A"ORGANIZATIONAL VEHICLE TRAIL "A"
P O
L
UAV
LARGE TEMF
SATS, ASLMS, & COMVAN
P O
L
H /Z
H /Z
R R
ORGANIZATIONAL STORAGE BUILDING
MAIN ROAD
A C
C E
S S R
O A
D
ORGANIZATIONAL VEHICLE TRAIL "A"
ORGANIZATIONAL VEHICLE TRAIL "A"ORGANIZATIONAL VEHICLE TRAIL "A"
(COF1E)
COMPANY OPERATIONS FACILITY
(BNHQE)
BATTALION HEADQUARTERS
(EXISTING)
MAIN ROAD
D
D
ORGANIZATIONAL STORAGE BUILDING HARDSTAND
TEDESCO ROAD
L A
K E R
O A
D
F A
C
IL
IT
Y
C O
F E
C O
M P
A N
Y O
P E
R A
T
IO
N S
(G R
A V
E L
U N
P A
V E
D R
O A
D
CCCCCC
C
C
C
C
C
C C
C
C
R4-MH407D
R4-MH407CR4-MH407B
R4-MH407A
R4-MH406A
R4-MH409A
R4-MH409B
R4-MH409C
R4-MH409D
R4-MH404A
R4-MH408
R4-MH407
R4-MH409
R4-MH405
R4-MH404
TEDESCOWAY
C
R4-MH407E
H
C
E=3120607.71
N=10392297.18
E=3120558.89
N=10392163.18
HARDSTAND FINISH GRADE.
ADJUST COMM MANHOLE TO MATCH
0 602060
SCALE: 1" = 60'-0"
ES102
E X
T E
R
IO
R T
E L E
C O
M M
U N
IC
A T
IO
N P
L A
N
2 2 2 2
N
SHEET KEYNOTES
7.
6.
5.
4.
3.
2.
1.
INTO MANHOLE.
CORE DRILL INTO EXISTING MANHOLE AND EXTEND DUCTS
FOR ADDITIONAL INFORMATION.
COMMUNICATION HANDHOLE FOR FUTURE CATV . SEE ET601
4" CONDUIT FROM TELECOMMUNICATION RM TO
TO TELECOMMUNICATION EQUIPMENT RM.
PULL WIRE.
- SECOND AND THIRD INNER DUCT ARE SPARE WITH
R4-MH404.
(R4-FOC10, 145-156). TIE-IN POINT IS IN MANHOLE
- FIRST INNER DUCT SHALL HAVE 12 STRAND SMFOC
DUCTS:
B) SECOND DUCT SHALL HAVE 3-3" FABRIC MESH INNER
R4-MH404.
(R4-06 PAIRS, 1301-1400). TIE-IN POINT IS IN MANHOLE
A) FIRST DUCT IS FOR 100 PAIR COPPER TELEPHONE CABLE
2-4" CONCRETE ENCASED DUCT BANK:
THRU MANHOLE R4-MH407E AND NEW DUCT SYSTEM.
STRAND SMFOC (R4-FOC10, 145-156) TO THE NEW BUILDING
COPPER TELEPHONE CABLE (R4-06 PAIRS, 1301-1400) AND 12
OF MANHOLE R4-MH407D FOR FUTURE USE. BRING IN 100-PAIR
LEAVE 12 STRAND SMFOC (R4-FOC10, 157-168) IN SPLICE CASE
SYSTEM VIA SPARE DUCT AND SPARE INNER DUCT.
MANHOLE R4-MH404 TO R4-MH407D THRU EXISTING DUCT
1301-1400) AND 24 STRAND SMFOC (R4-FOC10, 145-168) FROM
BRING IN 100-PAIR COPPER TELEPHONE CABLE (R4-06 PAIRS,
INSTALLATION AND SPLICING WITH COR.
THE SPLICE CASE IN THE MAINHOLE. COORDINATE
1301-1400) AND 24 STRAND SMFOC (R4-FOC10, 145-168) FROM
SPLICE 100-PAIR COPPER TELEPHONE CABLE (R4-06 PAIRS,
GENERAL SHEET NOTES
MANHOLE/HANDHOLE/TRANSFORMER.
CENTER POINT OF THE
PROVIDED COORDINATE IS AT THE 1.
Fort Worth District
KNOX BOX
8.
MECHANICAL RM 156.
BOX TO FIRE ALARM PANEL IN
ALARM TAMPER CIRCUIT FROM KNOX
1" CONDUIT WITH WIRING FOR FIRE
ES501
X
T E
R
IO
R E
L E
C T
R
IC
A L D
E T
A
IL
of Engineers
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
$FILEL$
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
$DATE$ $TIME$
S u b m it te d b y
C h e c k e d b y
D ra w n b y
D e s ig n e d b y
P L
O T D
A T
E
P L
O T S
C A
L E
F O
R T H
O O
D T
E X
A S
T
H A
IR
D
E F
E N
S E A
R T
IL
L E
R Y D
IV
IS
IO
N
P N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
T
A Y
L O
R S
T
F O
R T W
O R
T H T
X
S U
P P
L Y S
U P
P O
R T A
C T
IV
IT
Y W
A R
E H
O U
S E
S o li c it a ti o n N o
C o n tr a c t
N o
Is s u e D a te
G
C H
O A
T E
G
C H
O A
T E
E N
G
IN
E E
R
IN
G B
R A
N C
H
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G
NUMBER
SHEET
D
B R
O W
N P .E
C H
IE
F E
L E
C T
R
IC
A L S
E C
T
IO
N D
A R
E N A
B R
O W
N P .E
W
G -1
-B -0
J U
N E
GROUND RING
#1/0 COPPER (TYPICAL OF 4)
GROUND ROD
#1/0 COPPER
X0 TERMINAL
ARRESTOR GROUND
#4 COPPER SURGE
GROUND BUS OR PAD GROUND BUS OR PAD
AS REQURED
NO. OF CONDUITS PRIMARY NEUTRAL GROUND
MIN.
3'
GROUNDING SYSTEM
CONNECT TO BUILDING
COMPARTMENT
LOW VOLTAGE
COMPARTMENT
HIGH VOLTAGE
CHAMFER
EXPOSED
BUSHING
GROUNDING
MIN.
GRAVEL
SUB-BASE
CONCRETE ENCASEMENT
FOR PRIMARY CONDUIT
SECONDARY SERVICE
FINISHED GRADE
TRANSFORMER
METAL ENCLOSED
M
IN
GROUND
#1/0 COPPER
GROUND ROD
EDGES
WALLS.
SHALL OPEN AWAY FROM SCREEN
SO THAT TRANSFORMER DOORS
NOTE: SET TRANSFROMER ON PAD,
4"
"4
2"
4"
" x 10' 4
1" PVC
M
IN
GENERAL NOTES:
WITH COR.
STUB 6" AFG. COORDINATE
WATTMETER IN A BUILDING.
1" C WITH PULLWIRE TO A
CONDUIT
SLEEVE
2.
1.
PAD.
OTHER BOLLARDS. BOLLARDS SHALL ENCIRCLE EACH TRANSFORMER
FROM THE EDGE OF THE CONCRETE PAD, AS WELL A 48" FROM
PADS AS BOLLARDS. BOLLARDS SHALL BE LOCATED 24" AWAY
COOLING TOWERS SHALL HAVE 8" PIPE GUARDS SURROUNDING THE
ALL OF THE TRANSFORMERS AND PADS TO THE BUILDINGS AND THE
FOR DISTRIBUTION CENTERS.
PAD-MOUNTED TRANSFORMERS ARE COVERED BY OTHER DETAILS
VARIOUS BUILDINGS AND THE COOLING TOWERS. ALL OTHER
THIS DETAIL IS SPECIFICALLY FOR TRANSFORMERS TO SERVE THE
ES501ES101
SCALE: N.T.S
PAD MOUNTED TRANSFORMER GROUNDING DETAIL
ES501ES101
SCALE: N.T.S
PAD MOUNTED TRANSFORMER DETAIL
GROUND
#4 COPPER
GROUNDS
CABLE SHIELD
10" OR PAD
GROUND BUS
6" COMPACTED
CONDUIT
STEEL
RIGID
METALLIC TO NON-METALLIC
CONDUIT ADAPTER
ELEVATION
PLAN
ARM FOR HOLD DOWN BOLTING
MARK COVER APPROPRIATELYLIFT HOLES
M
IN
M
IN
MAXIMUM EXTENSION
COVER USED AS AN
PULLBOX WITHOUT
REINFORCING
FABRIC
PROVIDE WIRE
CAPILLARY FILL
MINIMUM REQUIREMENTS: BOX INTERIOR
1/2" DIA. x 3" LONG WITH 2" ARM
2" DUCT 1
2"
M
IN
6" DEEP GRAVEL
THICK WALLS AND 1-7/8" THICK COVER
SIZE 22" LONG x 12" WIDE WITH 1-1/2"
BELOW GRADE.
MUST BE 2'-0" MIN.
TO WHERE CONDUIT
2'-0" MAX. DISTANCE
COVER
ELECTRICAL PLANS.
REQUIRED. SEE EXTERIOR
NO. & SIZE OF DUCTS AS
CONSTR. JT.
OPTIONAL
PULL RING
END BELLS & PLUGS
RACK
CABLE
4 SIDES OF OPNG.
2- #6
M
IN
(SQ. OR O)
CONSTR. JOINT
(DESIGN FOR H2O WHEEL LOAD)
CAST IRON FRAME & COVER
BOLTED ON COVER
SEE NOTE 5
SEE NOTE 3
SEE NOTE 4
SEE NOTE 2
LEAD CONNECTIONS
EXOTHERMIC WELD
UNDERGROUND STRUCTURE
1.
NOTES:
2.
3.
4.
5.
6.
ADDITIONAL TEST LEAD, IF REQUIRED SHALL BE COLOR CODED RED.
FOR TESTING.
LEAVE SUFFICIENT SLACK IN LEADS TO ALLOW REMOVAL OF THE COVER
IF APPROVED BY THE CONTRACTING OFFICER.
OTHER COMMERCIALLY AVAILABLE TEST STATIONS WILL BE ACCEPTABLE
NATURAL GRADE
FINISHED
RECEIVE THE TEST LEADS.
CONTACT TERMINAL STRIP BOLTED TO COVER AND READY TO
CAST IRON OR PLASTIC. THE BOX SHALL BE COMPLETE WITH A TWO
CURB BOX SHALL BE A STANDARD PRODUCT, AND MAY BE MADE OF
7.
& PLUGS (TYP)
4-4" FORMED OPENINGS
E.W. AT CENTER
#6 @ 12" O.C.
8"
48"
8"
30"
12"
M
IN
"4"
M
IN
1"
NEVER MORE THAN 500' FROM THE LAST STATION.
THAN 500' IN LENGTH, BUT THEY SHALL BE SPACED EVENLY AND
LONG. TEST STATIONS SHALL ALSO BE INSTALLED ON PIPES LONGER
A TEST STATION SHALL BE INSTALLED FOR ALL PIPES LESS THAN 500'
PLAN VIEW
SPECIFICATIONS, OR AS DIRECTED BY THE CONTRACTING OFFICER.
THE TYPE OF TEST STATION SHALL BE AS SPECIFIED IN THE
PAINTED YELLOW
24"X24"X12"
CONCRETE BASE
ES501ES101
SCALE: N.T.S
(FOR POTENTIAL MEASUREMENTS)
TEST STATION - FLUSH MOUNTED
LEAD SHALL BE COLOR CODED RED.
CONTRACT DRAWINGS OR IN THE SPECIFICATIONS. THE TEST
PROVIDE ONE TEST LEAD UNLESS OTHERWISE INDICATED ON THE
VOTAGE
LOW
ES501ES102
SCALE: N.T.S
PULL BOX DETAIL
ES501ES102
SCALE: N.T.S
HANDHOLE DETAIL
CONCRETE PAD W/#4 @ 12"
O.C.E.W.
ES502
X
T E
R
IO
R E
L E
C T
R
IC
A L D
E T
A of Engineers
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
$FILEL$
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
$DATE$ $TIME$
S u b m it te d b y
C h e c k e d b y
D ra w n b y
D e s ig n e d b y
P L
O T D
A T
E
P L
O T S
C A
L E
F O
R T H
O O
D T
E X
A S
T
H A
IR
D
E F
E N
S E A
R T
IL
L E
R Y D
IV
IS
IO
N
P N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
T
A Y
L O
R S
T
F O
R T W
O R
T H T
X
S U
P P
L Y S
U P
P O
R T A
C T
IV
IT
Y W
A R
E H
O U
S E
S o li c it a ti o n N o
C o n tr a c t
N o
Is s u e D a te
G
C H
O A
T E
G
C H
O A
T E
E N
G
IN
E E
R
IN
G B
R A
N C
H
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G
NUMBER
SHEET
D
B R
O W
N P .E
C H
IE
F E
L E
C T
R
IC
A L S
E C
T
IO
N D
A R
E N A
B R
O W
N P .E
W
G -1
-B -0
J U
N E
4" CONDUITS
4" CONDUITS
12"
3' MIN. FOR ABOVE 600V
2' MIN. FOR 600V & BELOW.
2' MIN. FOR COMMUNICATIONS
MIN.
6"
S A
N D
B E
D CONDUIT
O.D.
MIN.
4"
TOP OF FINISHED GRADE
COMPACT EACH LAYER TO 95% MAXIMUM DENSITY.
BACKFILL MATERIAL CLASSIFIED SATISFACTORY; PLACE
SANDBEDDING FOR SECONDARY, 3000 PSI CONCRETE
FOR PRIMARY AND COMMUNICATIONS. SEE CONCRETE
ENCASED DETAILS ON THIS SHEET.
MARKING TAPE, RED, WITH IDENTIFYING LETTERING
(1750 PSI LENGTHWISE X 1500 PSI CROSSWISE
MINIMUM STRENGTH).
OPERATED MACHINE COMPACTORS (8" FOR OTHERS).
IN LIFTS NOT EXCEEDING 6" (LOOSE) FOR HAND
5 MIL MINIMUM X 6" WIDE, POLYETHYLENE
12"
2' MIN. FOR 600V & BELOW.
2' MIN. FOR COMMUNICATIONS
3' MIN. FOR ABOVE 600V
TOP OF PAVING
COMPACT EACH LAYER TO 95% MAXIMUM DENSITY.
BACKFILL MATERIAL CLASSIFIED SATISFACTORY; PLACE
3000 PSI CONCRETE. SEE CONCRETE ENCASED DETAILS
ON THIS SHEET. DYE CONCRETE RED FOR PRIMARY.
MARKING TAPE, RED, WITH IDENTIFYING LETTERING
(1750 PSI LENGTHWISE X 1500 PSI CROSSWISE
MINIMUM STRENGTH).
5 MIL MINIMUM X 6" WIDE, POLYETHYLENE
IN LIFTS NOT EXCEEDING 6" (LOOSE) FOR HAND
OPERATED MACHINE COMPACTORS (8" FOR OTHERS).
O.D.
CONDUIT
CONCRETE ENCASED TRENCH.
SEE CONCRETE ENCASED DETAILS ON THIS SHEET FOR
EXISTING BITUMINOUS PAVING
NEW HOT MIX SURFACE COURSE
COAT
TACK
SAWCUT EXISTING PAVING
EXISTING BITUMINOUS PAVING
TOP OF PAVING
12"
3000 PSI CONCRETE.
3' MIN. FOR ABOVE 600V
2' MIN. FOR 600V & BELOW.
2' MIN. FOR COMMUNICATIONS
CONDUIT
O.D.
CONCRETE ENCASED TRENCH.
SEE CONCRETE ENCASED DETAILS ON THIS SHEET FOR
COMPACT EACH LAYER TO 95% MAXIMUM DENSITY.
BACKFILL MATERIAL CLASSIFIED SATISFACTORY; PLACE
3000 PSI CONCRETE. SEE CONCRETE ENCASED DETAILS
ON THIS SHEET. DYE CONCRETE RED FOR PRIMARY.
MARKING TAPE, RED, WITH IDENTIFYING LETTERING
(1750 PSI LENGTHWISE X 1500 PSI CROSSWISE
MINIMUM STRENGTH).
5 MIL MINIMUM X 6" WIDE, POLYETHYLENE
IN LIFTS NOT EXCEEDING 6" (LOOSE) FOR HAND
OPERATED MACHINE COMPACTORS (8" FOR OTHERS).
6-WAY
3"
2" min.
3" min.2"
2" min.
3"
4-WAY3-WAY
min.3" 3"
1-WAY
3" 3"
3"
3"
3" 2" min. min.
2"
3" min.3"
2-WAY
3" 2" min. 3"
3"
3"
3"
2" min.
3"
3" min.2"
MINIMUM
10' O R C
O N
C R
E T
E D
IT
C H
E D
G E O
F P
A V
E M
E N
T
S E
E N
O T
E
FINISHED GRADE
STEEL PIPE CASING
E D
G E O
F P
A V
E M
E N
T
MINIMUM
10'
CONCRETE
A
A
4" DUCT (TYP)
2"
20" (MIN.) STEEL PIPE CASING
SECTION A-A
COMMUNICATIONS DUCTS.
AND 4" WIDE TRENCH FOR SECONDARY AND
6" WIDE TRENCH FOR PRIMARY ELECTRICAL DUCTS
SHEET FOR CONCRETE ENCASED TRENCH. MINIMUM
TRENCH. SEE CONCRETE ENCASED DETAILS ON THIS
3 TIMES CONDUIT DIAMETER FOR SAND BED CONDUIT
ES502
SCALE: N.T.S
PRIMARY & SECONDARY IN NON-PAVED AREAS
DETAIL FOR UNDERGROUND COMMUNICATIONS, ELECTRICAL
ES102
ES101
ES502
SCALE: N.T.S
ES102
ES101
PRIMARY & SECONDARY UNDER NEW PAVING
DETAIL FOR UNDERGROUND COMMUNICATIONS, ELECTRICAL
ES502
SCALE: N.T.S
ES102
ES101
PRIMARY & SECONDARY UNDER EXISTING PAVING
DETAIL FOR UNDERGROUND COMMUNICATIONS, ELECTRICAL
IN ORDER TO EASILY IDENTIFY LOCATION OF FIBER OPTIC LINES.
TRACER WIRE SHALL BE PLACED ON TOP OF THE DUCT BANK
ADJACENT ELECTRIC POWER AND COMMUNICATION DUCTS.
NOTE: 3" OF CONCRETE SHALL BE PROVIDED BETWEEN
3"
ES502
SCALE: N.T.S
ES102
ES101
CONCRETE ENCASED DUCT DETAILS
4. DISTANCE SHALL BE A MINIMUM OF 4' BELOW STREET LEVEL.
COMPLETION OF BORE.
ATIONS SHALL BE REPAIRED WITH SOLID SOD WITHIN ONE WEEK AFTER
TATIVE BEFORE DIGGING BEGINS. TURFING DISTURBED BY BORING OPER-
LOCATIONS MUST BE APPROVED BY CONTRACTING OFFICER'S REPRESEN-
ATIONS SHALL BE REPAIRED TO THEIR ORIGINAL CONDITION. BORING PIT
3. ANY DEMOLITION OF DITCHES, CONCRETE LINES, ETC. FROM BORING OPER-
OF 10' FROM STREET.
2. STREET OR CONCRETE DITCH SIDE OF BORE PIT SHALL BE A MINIMUM
BE FILLED WITH CONCRETE.
1. STEEL CASING SHALL BE INSTALLED BY DRY BORING JACKING. VOID TO
ES502
SCALE: N.T.S
ROAD BORING DETAIL
ES101
TRACER WIRE.
TRACER WIRE.
TRACER WIRE.
ES503
X
T E
R
IO
R E
L E
C T
R
IC
A L D
E T
A of Engineers
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
$FILEL$
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
$DATE$ $TIME$
S u b m it te d b y
C h e c k e d b y
D ra w n b y
D e s ig n e d b y
P L
O T D
A T
E
P L
O T S
C A
L E
F O
R T H
O O
D T
E X
A S
T
H A
IR
D
E F
E N
S E A
R T
IL
L E
R Y D
IV
IS
IO
N
P N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
T
A Y
L O
R S
T
F O
R T W
O R
T H T
X
S U
P P
L Y S
U P
P O
R T A
C T
IV
IT
Y W
A R
E H
O U
S E
S o li c it a ti o n N o
C o n tr a c t
N o
Is s u e D a te
G
C H
O A
T E
G
C H
O A
T E
E N
G
IN
E E
R
IN
G B
R A
N C
H
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G
NUMBER
SHEET
N
NORTH
TRUE
D
B R
O W
N P .E
C H
IE
F E
L E
C T
R
IC
A L S
E C
T
IO
N D
A R
E N A
B R
O W
N P .E
W
G -1
-B -0
J U
N E
T E
L E
P H
O N
E
E L
E C
T R I C
ELECTRIC
1"
MANHOLE
WALL
3"
SIDE VIEW
0.2"
2" 5" 2"
BOLTS AND
EXPANSION
SHIELDS
OF 2" X 0.4"
PORCELAIN
INSULATOR
2" RADIUS
1"
CABLE RACK
FASTEN BY MEANS
GRADE
FINISHED
APPROX. 0.6"
C.I. FRAME AND COVER
(DESIGN FOR H20 WHEEL
LOAD)
GROUT
2" CLR.
M
IN
CONSTR.
JOINT
O.C.E.W.
AT CENTER
3" CLR.
SUMP COVER
CAST METAL
5"
SECTION
12"
1"
CABLE-PULLING
IRON
8"(TYP.)
DIAGONAL BARS (1 EA.)
CORNER OF SUMP.
PROVIDE 4#4 x 36"
8" MIN.
M
IN
(TYP.)
24"
2" CLR.
1" CLR.
CABLE
RACKS
OPTIONAL
CONSTR.
JOINT
10"
AND FRAME
REQUIRED
DUCTS AS
144"
#4 SPACED AS SHOWN
PLAN
CAST METAL
SUMP COVER
AND FRAME
RACKS
CABLE
CSYM. ABOUT L
CL
ES503
SCALE: N.T.S
COMMUNICATION MANHOLE DETAIL
ES102
0.5" 12"
SUMP FRAME AND COVER
13"
0.4"
15"
MANHOLE
WALL
INSTALL
BEHIND VERTICAL
REINFORCEMENT
BARS.
PLAN VIEW
CABLE-PULLING IRON
.7
3"
3" R.
3.5"
32"
42"
21"
ENTRANCE FRAME
" 2
ENTRANCE COVER
32"
TELEPHONE
COVER
HANDLE
3"
0.4"
ES503
SCALE: N.T.SES101
ELECTRICAL MANHOLE DETAIL
0.5" 12"
15"
SUMP FRAME AND COVER
13"
0.4"
5"2"
0.2"
1"
2"
BOLTS AND
EXPANSION
SHIELDS
OF 2" x 0.4"
FASTEN BY MEANS
PORCELAIN
INSULATOR
2" RADIUS
CABLE RACK
AS REQUIRED BY SPECIFICATIONS.
OF HOOKS AND INSULATORS
NOTE: INSTALL NUMBER
REQUIRED
DUCTS AS
72"
RACKS
CABLE
CAST METAL
SUMP COVER
SYM. ABOUT LC
PLAN C.I. FRAME AND COVER
(DESIGN FOR H20 WHEEL
LOAD)
GROUT
2" CLR.
GRADE
FINISHED
APPROX. 0.6"
M
IN
OPTIONAL
CONSTR.
JOINT
CABLE
RACKS
1" CLR.
2" CLR.
24"
(TYP.)
10"
8" MIN.
CABLE-PULLING
IRON
CAST METAL
AND FRAME
SUMP COVER
JOINT
CONSTR.
O.C.E.W.
AT CENTER
GROUND ROD
0.75" X 10'.
CLR.
3"
5" 12"
SECTION
DIAGONAL BARS (1 EA.)
CORNER OF SUMP.
PROVIDE 4#4 x 36"
AND FRAME
MANHOLE
WALL
SIDE VIEW
3"
REINFORCEMENT
BARS.
WALL
INSTALL
MANHOLE
.7
3"
3.5"
3"
PLAN VIEW
CABLE-PULLING IRON
" 32"
21"
ENTRANCE FRAME
" 2
32"
COVER
HANDLE
ENTRANCE COVER
0.4"
3"
CL
8" (TYP.)
4"
BEHIND VERTICAL
42"
#4 @ 12"
#4 @ 12"
#4 SPACED AS SHOWN
E-001
T E
R
IO
R E
L E
C T
R
IC
A L L
E G
E of Engineers
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
$FILEL$
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
$DATE$ $TIME$
S u b m it te d b y
C h e c k e d b y
D ra w n b y
D e s ig n e d b y
F O
R T H
O O
D T
E X
A S
T
H A
IR
D
E F
E N
S E A
R T
IL
L E
R Y D
IV
IS
IO
N
P N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
T
A Y
L O
R S
T
F O
R T W
O R
T H T
X
S U
P P
L Y S
U P
P O
R T A
C T
IV
IT
Y W
A R
E H
O U
S E
S o li c it a ti o n N o
C o n tr a c t
N o
Is s u e D a te
G
C H
O A
T E
G
C H
O A
T E
E N
G
IN
E E
R
IN
G B
R A
N C
H
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G
NUMBER
SHEET
D
B R
O W
N P .E
C H
IE
F E
L E
C T
R
IC
A L S
E C
T
IO
N D
A R
E N A
B R
O W
N P .E
W
G -1
-B -0
A U
G U
S T
GENERAL SHEET NOTES
E
N
L
XX
/3
P
30/3P
15A
TVSS
C2
APPEAR ON THE OTHER ELECTRICAL DRAWINGS.
NOT ALL SYMBOLS SHOWN ON THIS SHEET MAY
ROUND PENDANT HIGH BAY FIXTURE.
ROUND PENDANT HIGH BAY FIXTURE WITH EMERGENCY BATTERY.
ROUND DOWNLIGHT FIXTURE.
ROUND DOWNLIGHT FIXTURE WITH EMERGENCY BATTERY.
EXTERIOR WALL MOUNTED LIGHT FIXTURE.
HAND-OFF-AUTO SELECTOR SWITCH.
TOGGLE SWITCH.
PUSHBUTTON NORMALLY CLOSED
PUSHBUTTON NORMALLY CLOSED
PUSHBUTTON NORMALLY OPEN
NORMALLY CLOSED CONTACT
NORMALLY OPEN CONTACT
ARRESTOR VALVE
ARRESTOR
TRANSIENT VOLTAGE SURGE SUPPRESSOR
TRANSFER SWITCH. RATINGS AS INDICATED.
TRANSFORMER WITH GROUND. RATINGS AS INDICATED.
THERMAL OVERLOAD DEVICE
IN-LINE POWER FUSE DEVICE
FUSE. TRIP RATING AS INDICATED
30/3P INDICATES 30A 3 POLE.
SWITCH. SIZE AND RATINGS AS LISTED.
60/3 INDICATES 60 AMP RATING, 3 POLE
THERMAL MAGNETIC CIRCUIT BREAKER
CURRENT TRANSFORMER
POTENTIAL TRANSFORMER
DIGITAL MULTI-METER
GROUND
BATTERY
ANTENNA6" ABOVE COUNTER LEVEL
AMP FRAME. USED IN CONJUNCTION WITH "AT"
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AMP TRIP. USED IN CONJUNCTION WITH "AF" OR "NF"
BUILDING AUTOMATION SYSTEM OR SUBCONTRACTOR
BELOW FINISHED GRADE
IN STATEMENT IS ABBREVIATION FOR "CONDUIT"
AT DEVICE INDICATES DEVICE FOR CENTRAL CLOCK SYSTEM
CABLE/TV SYSTEM
AT DEVICE INDICATES DEVICE FOR CLOSED CIRCUIT TV SYSTEM
CIRCUIT
CONTRACTING OFFICER REPRESENTATIVE
DEVICE DEDICATED FOR COPIER
AT DEVICE INDICATES DEVICE FOR DATA SYSTEM
DOUBLE POLE SINGLE THROW SWITCH/MECHANISM
ELECTRICAL CONTRACTOR
EQUIPMENT MANUFACTURER
AT DEVICE INDICATES DEVICE IS EXISTING
AC
AF
AFF
AFG
AT
BAS
BFG
C
C
CATV
CCTV
CKT
C.O.R.
CPR
D
DPST
FUSIBLE SWITCH
FIRE PROTECTION TRADE/SUBCONTRACTOR
FULL VOLTAGE NON-REVERSING
GENERAL CONTRACTOR
FIBER OPTIC CABLE
DEVICE DEDICATED FOR MICROWAVEMO
FRACTIONAL HORSEPOWER CONTROLLER
ISEC
MASS NOTIFICATION SYSTEM
INFORMATION SYSTEMS ENGINEERING COMMAND
MANHOLE
HORSEPOWER
JUNCTION BOX
MECHANICAL/TRADES. DIVISION 15.
KITCHEN EQUIPMENT CONTRACTOR
FHC
EX
FPC
FVNR
FS
EM
GFIP
GFCI
MH
EC
JB
MOTOR CONTROL CENTERMCC
GF
HAND-OFF-AUTOHOA
FOC
HP
GC
KEC
MNS
MC
RELAY
NOT IN CONTRACT
SINGLE MODE
RIGID METAL CONDUIT
SINGLE POLE SINGLE THROWSPST
NOT FUSED/NON-FUSIBLE SWITCH
MANUAL STARTING SWITCH
SWITCH
PANELBOARDPNLBD
OUTSIDE PLANT (TELECOMMUNICATIONS)OSP
UNLESS NOTED OTHERWISE
WEATHERPROOF (NEMA 3R)
DEVICE DEDICATED FOR VENDING
SINGLE POLE DOUBLE THROW
UNO
REL
V
UPS
MS
SW
NIC
NF
WP
RFR
ON CENTER
SPDT
DEVICE DEDICATED FOR REFRIGERATOR
SM
RMC
O.C
XP
RATED. SEE LIFE SAFETY PLAN FOR AREA RATINGS.
AT DEVICE INDICATES DEVICE IS EXPLOSION PROOF
GOCO GOVERNMENT OWNER CONTRACTOR OPERATED
GROUND FAULT CIRCUIT INTERRUPT DEVICE
GROUND FAULT CIRCUIT INTERRUPT PROTECTED OUTLET
GROUND FAULT INTERRUPT PROTECTION
UNINTERRUPTED POWER SUPPLY
KEYED NOTE
GROUND LEVEL CONDUCTOR RUN.
ABOVE GRADE CONDUCTOR RUN.
BONDING TO BUILDING STEEL
ALUMINUM AIR TERMINAL. SIZE PER SPECIFICATION.
MECHANICAL EQUIPMENT.
SCHEDULED FEEDER
FOR CLARIFICATION.
SPECIFIC BONDING POINT SHOWN IN PLANS
UNSWITCHED CIRCUIT PHASE CONDUCTOR.
BATTERY. CONNECT EMERGENCY BALLAST TO
RECESS MOUNTED FIXTURE WITH EMERGENCY
CIRCUIT PHASE CONDUCTOR.
BATTERY. CONNECT EMERGENCY BALLAST TO UNSWITCHED
SURFACE/PENDANT MOUNTED FIXTURE WITH EMERGENCY
EMERGENCY BATTERY.
EXTERIOR WALL MOUNTED LIGHT FIXTURE WITH
TYPICAL FOR ALL CONFIGURATIONS
FACE(S). ARROW DENOTES DIRECTIONAL ARROW.
CEILING MOUNTED EXIT SIGN. FILLED AREA INDICATES
MOTOR CONTROL CENTER
STARTER. PART OF PROTECTIVE DEVICE IN
TYPICAL FOR ALL CONFIGURATIONS
FACE(S). ARROW DENOTES DIRECTIONAL ARROW.
WALL MOUNTED EXIT. FILLED AREA INDICATES
A B-12c
B-12cA
A B-12c
B-12cA
A B-12c
B-12cA
"TW" INDICATES TEST WELL.
GROUND ROD/BONDING, 3/4" DIA X 10' COPPER-GLAD STEEL. TW
LIGHTNING PROTECTION SYMBOLS
GENERAL SYMBOLS
ELECTRICAL ABBREVIATIONS ONE-LINE DIAGRAM SYMBOLS
XX-#X
SURFACE/PENDANT/WALL MOUNTED FIXTURE.
a a
ALL FIXTURES.
"B" INDICATES PANEL. "c" PRECEDING CIRCUIT NO. INDICATES SWITCH LEG TYPICAL FOR
FIXTURE TYPE. "a" DONATES SWITCH WITH THE SAME LETTER OPERATES THIS FIXTURE.
RECESS MOUNTED FIXTURE. "A" INDICATES
DM
NATIONAL ELECTRICAL CODE.
16. ALL ELECTRICAL WORK SHALL COMPLY WITH THE
UTILIZED OUTDOORS OR IN WET LOCATIONS.
LIQUID TIGHT FLEXIBLE METAL CONDUIT SHALL BE
OR ANY OTHER EQUIPMENT THAT MAY VIBRATE.
TO ANY MOTOR, COMPRESSOR, TRANSFORMER
MINIMUM OF TWO FEET PRIOR TO THE CONNECTION
15. FLEXIBLE METAL CONDUIT SHALL BE INSTALLED A
ARCHITECTURAL PLANS.
ENVELOPE REQUIREMENTS. SEE DETAILS ON THE
RECOMMENDATIONS, FIRE RATINGS, AND U-FACTOR /
SEALED IN ACCORDANCE WITH ROOF MANUFACTURER
14. ALL CONDUITS THAT PENETRATE THE ROOF SHALL BE
EQUIPMENT LOCATIONS AND FURNITURE LAYOUT.
13. DEVICE LOCATIONS SHALL BE COORDINATED WITH
BE RATED FOR 90 DEGREES C IN WET LOCATIONS.
12. ALL CONDUCTORS INSTALLED BELOW GRADE SHALL
NOTED.
CONDUCTOR SIZE SHALL BE #12 UNLESS OTHERWISE
11. MINIMUM CONDUIT SIZE SHALL BE 1/2 INCH, MINIMUM
SURFACE AND BUILDING FLOOR.
CONDUITS PRIOR TO PENETRATING THE SOIL
CONDUIT WILL BE PROVIDED FOR ALL UNDERGROUND
10. TRANSITION FROM PVC TO PVC-COATED RIGID STEEL
PRIOR TO CONCRETE PLACEMENT.
CONTRACTOR IS TO INSTALL ALL CONDUITS AND SLEEVES
NO PENETRATIONS IN THE BUILDING FOUNDATION WALLS.
BE INSTALLED BELOW THE BUILDING FOUNDATION WITH
9. UNDERGROUND CONDUIT ENTERING THE BUILDING WILL
DETERMINE DEFICIENT DURING TESTING.
AE502 CORRECT ALL PENETRATIONS THAT ARE
WALL PENETRATION REQUIREMENTS REFER TO SHEET
WITH THE BUILDING AIR BARRIER REQUIREMENTS. FOR
8. ELECTRICAL PENETRATION OPENINGS SHALL COMPLY
RECOMMENDATION FOR EACH AREA REQUIRING SENSORS.
AND QUANTITY OF SENSORS PER MANUFACTURER
POSITION AND QUANTITY. PROVIDE PLACEMENT
AND PHOTOCELLS SENSORS IS FOR PROPOSED
7. PLACEMENT OF CEILING MOUNTED OCCUPANCY
FROM THE BRANCH CIRCUIT INDICATED.
SHALL HAVE AN UNSWITCHED PHASE CONDUCTOR
6. ALL LIGHT FIXTURES WITH AN EMERGENCY LED DRIVER
WITH DEDICATED NEUTRALS.
5. ALL 20A/1P BRANCH CIRCUITS SHALL BE PROVIDED
4. NOT USED.
CONDUCTORS PLUS ONE GROUND CONDUCTOR.
REQUIRED NUMBER OF SWITCHED OR TRAVELER
3. EACH SWITCH SHALL BE CONNECTED BY THE
THE MOST DISTANT POINT IN THE CIRCUIT.°
THE DISTANCE SHALL BE MEASURED FROM PANEL TO
BE A MINIMUM #8, PROVIDING A PIGTAIL IF NECESSARY.
BE A MINIMUM #10 AWG. CIRCUITS OVER 85' SHALL
2. 20A/1P, 120 VOLT BRANCH CIRCUITS 55' TO 85' SHALL
MAXIMUM 78" AFF, UNLESS NOTED OTHERWISE.
OF OPERATING HANDLE AT ITS HIGHEST POSITION IS
AND DISCONNECTING SWITCHES MOUNTED SO HEIGHT
ENCLOSED CIRCUIT BREAKERS, MOTOR CONTROLLERS
MOUNTED AT 48" AFF (CENTER), AND PANELBOARDS,
MOUNTED AT 18" AFF (CENTER), LIGHTING SWITCHES
1. RECEPTACLES AND TELECOMMUNICATIONS OUTLETS
A B-12c
B-12cA
A B-12c
B-12cA
A
B-12c
B-12c
A
LIGHTING SYMBOLS
E-002
T E
R
IO
R E
L E
C T
R
IC
A L L
E G
E of Engineers
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
$FILEL$
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
$DATE$ $TIME$
S u b m it te d b y
C h e c k e d b y
D ra w n b y
D e s ig n e d b y
F O
R T H
O O
D T
E X
A S
T
H A
IR
D
E F
E N
S E A
R T
IL
L E
R Y D
IV
IS
IO
N
P N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
T
A Y
L O
R S
T
F O
R T W
O R
T H T
X
S U
P P
L Y S
U P
P O
R T A
C T
IV
IT
Y W
A R
E H
O U
S E
S o li c it a ti o n N o
C o n tr a c t
N o
Is s u e D a te
G
C H
O A
T E
G
C H
O A
T E
E N
G
IN
E E
R
IN
G B
R A
N C
H
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G
NUMBER
SHEET
D
B R
O W
N P .E
C H
IE
F E
L E
C T
R
IC
A L S
E C
T
IO
N D
A R
E N A
B R
O W
N P .E
W
G -1
-B -0
A U
G U
S T
GENERAL SHEET NOTES
FLOOR MOUNTED RECEPTACLE. TYPE AS SHOWN.
PRE-WIRED CONTROL PANEL
L
2 & 3
NOTES
ELECTRIC WATER COOLER. MOUNT BEHIND EQUIPMENT SKIRT.
GFCI DUPLEX RECEPTACLE DEDICATED FOR
SM
GFCI
WP
EWC
PJ
TV
AC
APPEAR ON THE OTHER ELECTRICAL DRAWINGS.
NOT ALL SYMBOLS SHOWN ON THIS SHEET MAY
POWER AND SPECIAL SYSTEMS SYMBOLS
QUADRUPLEX RECEPTACLE. MOUNTED AT 18" AFF U.N.O.
SPLIT WIRED DUPLEX RECEPTACLE. MOUNTED AT 18" AFF U.N.O.
NEMA 5-20 SIMPLEX RECEPTACLE. WALL MOUNTED AT 18" AFF UNO.
WALL MOUNTED AT 18" AFF U.N.O.
NEMA 5-20 DUPLEX RECEPTACLE. TYPICAL FOR ALL RECEPTACLES U.N.O.
WALL MOUNTED AT 18" AFF U.N.O.
GFCI DUPLEX RECEPTACLE WITH WEATHERPROOF IN-USE COVER.
GFCI DUPLEX RECEPTACLE. WALL MOUNTED AT 18" AFF U.N.O.
WALL MOUNTED AT 18" AFF U.N.O.
OCCUPANCY SENSOR CONTROLLED, DUPLEX RECEPTACLE.
TV
POWER WHIP FOR MODULAR FURNITURE.
PWCP
HUBBELL #HBL5235 OR EQUAL
NEMA 5-20 "CLOCK" RECEPTACLE
DIRECT RELATIONSHIP TO NOTED DIAGRAM.
CEILING MOUNTED JUNCTION BOX. "2" SUBSCRIPT INDICATES
FOR ALL SWITCHES.
LETTERS INDICATE SWITCH LEG. TYPICAL
SINGLE POLE SWITCH. LOWER CHARACTER
DOUBLE POLE SWITCH (DPST)
THREE WAY SWITCH…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .