B3_W9126G19B0007_(Part_3_of_4).pdf

PDF 3 MB Posted

Attached to
FY19 RRAD General Purpose Warehouse
Solicitation number
W9126G19B0007
Issued by

About this file

Solicitation Part 3 of 4

View the file

Other files

File Type Posted
C1_SF_1409_Abstract_of_Offerors.pdf PDF
A7_Amendment_5.pdf PDF
A7_Amendment_4.pdf PDF
Amendment_3.pdf PDF
Site_Visit.pdf PDF
A7_Amendment_2.pdf PDF
A10_FF&E_Package_(GPW)_FINAL.pdf PDF
FFE_Package_(GPW)_FINAL.pdf PDF
B3_Amendment_1.pdf PDF
Drawings_(Part_2_of_9).pdf PDF
Drawings_(Part_5_of_9).pdf PDF
Drawings_(Part_6_of_9).pdf PDF
Drawings_(Part_7_of_9).pdf PDF
Drawings_(Part_1_of_9).pdf PDF
Drawings_(Part_9_of_9).pdf PDF
Drawings_(Part_3_of_9).pdf PDF
Drawings_(Part_8_of_9).pdf PDF
Drawings_(Part_4_of_9).pdf PDF
B3_W9126G19B0007_(Part_1_of_4).pdf PDF
B3_W9126G19B0007_(Part_2_of_4).pdf PDF
B3_W9126G19B0007_(Part_4_of_4).pdf PDF
Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FY19 DLA Gener al Pur pose War ehouse RD19DLA

SECTI ON 08 51 13

ALUMI NUM WI NDOWS

PART 1 GENERAL

1. 1 REFERENCES

The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o wi t hi n t he t ext by t he basi c desi gnat i on onl y.

ALUMI NUM ASSOCI ATI ON ( AA)

AA DAF45 ( 2003; Reaf f i r med 2009) Desi gnat i on Syst em f or Al umi num Fi ni shes

AMERI CAN ARCHI TECTURAL MANUFACTURERS ASSOCI ATI ON ( AAMA)

AAMA 1302. 4 ( 1973) Speci f i cat i ons f or For ced- Ent r y Resi st ant Al umi num Pr i me Wi ndows

AAMA 1503 ( 2009) Vol unt ar y Test Met hod f or Ther mal Tr ansmi t t ance and Condensat i on Resi st ance of Wi ndows, Door s and Gl azed Wal l Sect i ons

AAMA 611 ( 2014) Vol unt ar y Speci f i cat i on f or Anodi zed Ar chi t ect ur al Al umi num

AAMA/ WDMA/ CSA 101/ I . S. 2/ A440 ( 2011; Updat e 1 2014) Nor t h Amer i can Fenest r at i on St andar d/ Speci f i cat i on f or Wi ndows, Door s, and Skyl i ght s

ASTM I NTERNATI ONAL ( ASTM)

ASTM E1300 ( 2016) St andar d Pr act i ce f or Det er mi ni ng Load Resi st ance of Gl ass i n Bui l di ngs

ASTM F1642/ F1642M ( 2017) St andar d Test Met hod f or Gl azi ng and Gl azi ng Syst ems Subj ect t o Ai r bl ast Loadings

ASTM F2248 ( 2012) St andar d Pr act i ce f or Speci f y i ng an Equi val ent 3- Second Dur at i on Desi gn Loadi ng f or Bl ast Resi st ant Gl azi ng Fabr i cat ed wi t h Lami nat ed Gl ass

I NTERNATI ONAL WI NDOW CLEANI NG ASSOCI ATI ON ( I WCA)

I WCA I - 14. 1 ( 2001) Wi ndow Cl eani ng Saf et y St andar d

NATI ONAL FENESTRATI ON RATI NG COUNCI L ( NFRC)

NFRC 100 ( 2014) Pr ocedur e f or Det er mi ni ng Fenest r at i on Pr oduct U- Fact or s

NFRC 200 ( 2014) Pr ocedur e f or Det er mi ni ng

SECTI ON 08 51 13 Page 1

Fenest r at i on Pr oduct Sol ar Heat Gai n Coef f i c i ent and Vi s i bl e Tr ansmi t t ance at Nor mal I nci dence

1. 2 CERTIFICATION

Each pr i me wi ndow uni t must bear t he AAMA Label war r ant i ng t hat t he pr oduct compl i es wi t h AAMA/ WDMA/ CSA 101/ I . S. 2/ A440. Cer t i f i ed t est r epor t s at t est i ng t hat t he pr i me wi ndow uni t s meet t he r equi r ement s of AAMA/ WDMA/ CSA 101/ I . S. 2/ A440, i ncl udi ng t est s i ze, wi l l be accept abl e i n l i eu of pr oduct l abel i ng.

1. 3 SUBMITTALS

Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" desi gnat i on;

submi t t al s not havi ng a " G" desi gnat i on ar e f or i nf or mat i on onl y. When used, a desi gnat i on f ol l owi ng t he " G" desi gnat i on i dent i f i es t he of f i ce t hat wi l l r evi ew t he submi t t al f or t he Gover nment . Submi t t al s wi t h an " S" ar e f or i ncl usi on i n t he Sust ai nabi l i t y eNot ebook, i n conf or mance t o Sect i on 01 33 29 SUSTAI NABI LI TY REPORTI NG. Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00 SUBMI TTAL PROCEDURES:

SD- 02 Shop Dr awi ngs

Wi ndows; G

Fabr i cat i on Dr awi ngs

SD- 03 Pr oduct Dat a

Wi ndows; G

Har dwar e; G

Fast ener s; G

Wi ndow Per f or mance; G

Ther mal - Bar r i er Wi ndows; G

Mul l i ons; G

Weat her st r i ppi ng; G

Accessor i es; G

Adhesives

Submi t manuf act ur er ' s pr oduct dat a, i ndi cat i ng VOC cont ent .

Ther mal Per f or mance; G

SD- 04 Sampl es

Fi ni sh Sampl e

SECTI ON 08 51 13 Page 2

Wi ndow Sampl e

SD- 05 Desi gn Dat a

St r uct ur al Cal cul at i ons f or Def l ect i on; G

Desi gn Anal ysi s; G

Submi t desi gn anal ysi s wi t h cal cul at i ons showi ng t hat t he desi gn of each di f f er ent s i ze and t ype of al umi num wi ndow uni t and i t s anchor age t o t he st r uct ur e meet s t he mi ni mum ant i t er r or i sm st andar ds r equi r ed by par agr aph " Mi ni mum Ant i t er r or i sm Per f or mance" , unl ess conf or mance i s demonst r at ed by St andar d Ai r bl ast Test r esul t s. Cal cul at i ons ver i f y i ng t he st r uct ur al per f or mance of each wi ndow pr oposed f or use, under t he gi ven l oads, must be pr epar ed and si gned by a r egi st er ed Pr of essi onal Engi neer . The wi ndow component s and anchor age devi ces t o t he st r uct ur e, as det er mi ned by t he desi gn anal ysi s, must be r ef l ect ed i n t he shop dr awi ngs.

SD- 06 Test Repor t s

Mi ni mum Condensat i on Resi st ance Fact or

Resi st ance t o For ced Ent r y

St andar d Ai r bl ast Test ; G

For Mi ni mum Ant i t er r or i sm wi ndows, i n l i eu of a Desi gn Anal ysi s, r esul t s of ai r bl ast t est i ng, whet her by ar ena t est or shockt ube, must be i ncl uded i n a t est r epor t , pr ovi di ng i nf or mat i on i n accor dance wi t h ASTM F1642/ F1642M, as pr epar ed by t he i ndependent t est i ng agency per f or mi ng t he t est . The t est r esul t s must demonst r at e t he abi l i t y of each wi ndow pr oposed f or use t o wi t hst and t he ai r bl ast l oadi ng par amet er s and achi eve t he hazar d l evel r at i ng speci f i ed i n par agr aph " St andar d Ai r bl ast Test Method".

SD- 10 Oper at i on and Mai nt enance Dat a

Wi ndows, Dat a Package 1; G

Submi t i n accor dance wi t h Sect i on 01 78 23 OPERATI ON AND

MAI NTENANCE DATA.

Pl ast i c I dent i f i cat i on

When not l abel ed, i dent i f y t ypes i n Oper at i on and Mai nt enance Manual.

SD- 11 Cl oseout Submi t t al s

Recycl ed Cont ent of Al umi num Wi ndows; S

SECTI ON 08 51 13 Page 3

1. 4 QUALI TY ASSURANCE

1. 4. 1 Shop Dr awi ng Requi r ement s

Pr ovi de dr awi ngs t hat i ndi cat e el evat i ons of wi ndows, f ul l - s i ze sect i ons, t hi ckness and gages of met al , f ast eni ngs, pr oposed met hod of anchor i ng, s i ze and spaci ng of anchor s, det ai l s of const r uct i on, met hod of gl azi ng, det ai l s of oper at i ng har dwar e, mul l i on det ai l s , met hod and mat er i al s f or weat her st r i ppi ng, mat er i al and met hod of at t achi ng subf r ames, s i l l s , t r i m, i nst al l at i on det ai l s , and ot her r el at ed i t ems.

1. 4. 2 Sampl e Requi r ement s

1. 4. 2. 1 Fi ni sh Sampl e Requi r ement s

Submi t col or char t of st andar d f act or y col or coat i ngs when f act or y- f i ni sh col or coat i ng i s t o be pr ovi ded.

1. 4. 2. 2 Wi ndow Sampl e Requi r ement s

Submi t one f ul l - s i ze cor ner of each wi ndow t ype pr oposed f or use. Wher e scr eens or weat her st r i ppi ng i s r equi r ed, f i t sampl e wi t h such i t ems t hat ar e t o be used.

1. 4. 3 Desi gn Dat a Requi r ement s

Submi t cal cul at i ons t o subst ant i at e compl i ance wi t h def l ect i on r equi r ement s and Mi ni mum Ant i t er r or i sm Per f or mance cr i t er i a. A r egi st er ed Pr of essi onal Engi neer must pr ovi de cal cul at i ons.

Submi t desi gn anal ysi s wi t h cal cul at i ons showi ng t hat t he desi gn of each di f f er ent s i ze and t ype of al umi num wi ndow uni t and i t s anchor age t o t he st r uct ur e meet s t he r equi r ement s of par agr aph " Mi ni mum Ant i t er r or i sm Per f or mance Cr i t er i a" . Cal cul at i ons ver i f y i ng t he st r uct ur al per f or mance of each wi ndow pr oposed f or use, under t he gi ven l oads, must be pr epar ed and si gned by a r egi st er ed pr of essi onal engi neer . Ref l ect t he wi ndow component s and anchor age devi ces t o t he st r uct ur e, as det er mi ned by t he desi gn anal ysi s, i n t he shop dr awi ngs.

1. 4. 4 Test Repor t Requi r ement s

Submi t t est r epor t s f or each t ype of wi ndow at t est i ng t hat i dent i cal wi ndows have been t est ed and meet t he r equi r ement s speci f i ed her ei n f or conf or mance t o AAMA/ WDMA/ CSA 101/ I . S. 2/ A440 i ncl udi ng t est s i ze, and mi ni mum condensat i on r esi st ance f act or ( CRF) , and, f or Mi ni mum Ant i t er r or i sm wi ndows, i n l i eu of a Desi gn Anal ysi s, r esul t s of a St andar d Ai r bl ast Test .

1. 5 DELI VERY AND STORAGE

Del i ver wi ndows t o pr oj ect s i t e i n an undamaged condi t i on. Use car e i n handl i ng and hoi st i ng wi ndows dur i ng t r anspor t at i on and at t he j obsi t e.

St or e wi ndows and component s out of cont act wi t h t he gr ound, under a weat her t i ght cover i ng, so as t o pr event bendi ng, war pi ng, or ot her wi se damagi ng t he wi ndows. Repai r damaged wi ndows t o an " as new" condi t i on as appr oved. I f wi ndows can not be r epai r ed, pr ovi de a new uni t .

SECTI ON 08 51 13 Page 4

1. 6 PROTECTION

Pr ot ect f i ni shed sur f aces dur i ng shi ppi ng and handl i ng usi ng t he manuf act ur er ' s st andar d met hod. Do not appl y coat i ngs or l acquer s t o sur f aces t o whi ch caul k i ng and gl azi ng compounds must adher e.

1. 7 PLASTI C I DENTI FI CATI ON

Label pl ast i c pr oduct s pr ovi ded t o i ndi cat e t hei r pol ymer i c composi t i on accor di ng t o t he f ol l owi ng l i s t . Wher e pr oduct s ar e not l abel ed, pr ovi de pr oduct dat a i ndi cat i ng pol ymer i c i nf or mat i on i n Oper at i on and Mai nt enance Manual.

a. Type 1: Pol yet hyl ene Ter epht hal at e ( PET, PETE) .

b. Type 2: Hi gh Densi t y Pol yet hyl ene ( HDPE) .

c. Type 3: Vi nyl ( Pol yvi nyl Chl or i de or PVC) .

d. Type 4: Low Densi t y Pol yet hyl ene ( LDPE) .

e. Type 5: Pol ypr opyl ene ( PP) .

f . Type 6: Pol yst yr ene ( PS) .

g. Type 7: Ot her . Use of t hi s code i ndi cat es t hat t he package i n quest i on i s made wi t h a r esi n ot her t han t he s i x l i s t ed above, or i s made of mor e t han one r esi n l i s t ed above, and used i n a mul t i - l ayer combi nat i on.

1. 8 FI ELD MEASUREMENTS

Take f i el d measur ement s pr i or t o pr epar at i on of t he dr awi ngs and fabrication.

1. 9 PERFORMANCE REQUI REMENTS

1. 9. 1 Wi nd Loadi ng Desi gn Pr essur e

Desi gn wi ndow component s, i ncl udi ng mul l i ons, har dwar e, and anchor s, t o wi t hst and a wi nd- l oadi ng desi gn pr essur e as r equi r ed on st r uct ur al dr awi ngs.

1. 9. 2 Tests

Test wi ndows pr oposed f or use i n accor dance wi t h AAMA/ WDMA/ CSA 101/ I . S. 2/ A440 f or t he par t i cul ar t ype and qual i t y wi ndow specified.

Per f or m t est s by a nat i onal l y r ecogni zed i ndependent t est i ng l abor at or y equi pped and capabl e of per f or mi ng t he r equi r ed t est s. Submi t t he r esul t s of t he t est s as cer t i f i ed l abor at or y r epor t s r equi r ed her ei n.

Mi ni mum desi gn l oad f or a uni f or m- l oad st r uct ur al t est must be 50 psf .

1. 10 DRAWINGS

Submi t t he Fabr i cat i on Dr awi ngs f or al umi num wi ndow uni t s showi ng compl et e wi ndow assembl y i ncl udi ng har dwar e, weat her st r i ppi ng, and subf r ame assembl y

SECTI ON 08 51 13 Page 5 details.

1. 11 WI NDOW PERFORMANCE

Al umi num wi ndows must meet t he f ol l owi ng per f or mance r equi r ement s. Per f or m t est i ng r equi r ement s by an i ndependent t est i ng l abor at or y or agency.

1. 11. 1 St r uct ur al Per f or mance

St r uct ur al t est pr essur es on wi ndow uni t s must be f or posi t i ve l oad ( i nwar d) and negat i ve l oad ( out war d) . Af t er t est i ng, t her e wi l l be no gl ass br eakage, per manent damage t o f ast ener s, har dwar e par t s, suppor t ar ms or act uat i ng mechani sms or any ot her damage whi ch coul d cause wi ndow t o be i noper abl e. Ther e must be no per manent def or mat i on of any mai n f r ame, sash or vent i l at or member i n excess of t he r equi r ement s est abl i shed by AAMA/ WDMA/ CSA 101/ I . S. 2/ A440 f or t he wi ndow t ypes and cl assi f i cat i on speci f i ed i n t hi s sect i on.

1. 11. 2 Mi ni mum Ant i t er r or i sm Per f or mance

Wi ndows must meet t he mi ni mum ant i t er r or i sm per f or mance as speci f i ed i n t he par agr aphs bel ow. Conf or mance t o t he per f or mance r equi r ement s must be val i dat ed by one of t he f ol l owi ng met hods.

1. 11. 2. 1 Comput at i onal Desi gn Anal ysi s Met hod

Wi ndow f r ames, mul l i ons, and sashes must be desi gned t o t he cr i t er i a l i s t ed her ei n. Comput at i onal desi gn anal ysi s must i ncl ude cal cul at i ons ver i f y i ng t he st r uct ur al per f or mance of each wi ndow pr oposed f or use, under t he gi ven st at i c equi val ent l oads.

Desi gn ent i r e syst em t o wi t hst and t he i ndi cat ed ant i - t er r or i sm f or ce pr ot ect i on ( ATFP) st andar ds as shown on t he st r uct ur al dr awi ngs.

The gl azi ng f r ame bi t e f or t he wi ndow f r ames must be i n accor dance wi t h

ASTM F2248.

Wi ndow f r ames must be anchor ed t o t he suppor t i ng st r uct ur e wi t h anchor s desi gned t o r esi st t wo t i mes ( 2X) t he gl azi ng r esi st ance i n accor dance wi t h ASTM F2248 and ASTM E1300.

1. 11. 2. 2 Al t er nat e Dynami c Desi gn Anal ysi s Met hod

As an al t er nat i ve t o t he st at i c equi val ent l oad desi gn appr oach descr i bed above, wi ndow f r ami ng member s, anchor s, and gl azi ng may be desi gned usi ng a dynami c anal ysi s t o pr ove t he wi ndow syst em wi l l pr ovi de per f or mance equi val ent t o or bet t er t han a ver y l ow hazar d r at i ng i n accor dance wi t h ASTM F1642/ F1642M associ at ed wi t h t he appl i cabl e l ow l evel of pr ot ect i on f or t he pr oj ect .

1. 11. 2. 3 St andar d Ai r bl ast Test Met hod

As an al t er nat i ve t o ei t her of t he Comput at i onal Desi gn Anal ysi s Met hods, each Mi ni mum Ant i t er r or i sm wi ndow t ype must be t est ed f or eval uat i on of hazar ds gener at ed f r om ai r bl ast l oadi ng i n accor dance wi t h ASTM F1642/ F1642M by an i ndependent t est i ng agency r egul ar l y engaged i n bl ast t est i ng. For pr oposed wi ndow syst ems t hat ar e of t he same t ype as t he t est ed syst em but of di f f er ent s i ze, t he t est r esul t s may be accept ed pr ovi ded t he pr oposed wi ndow si ze i s wi t hi n t he r ange f r om 25 per cent smal l er t o 10 per cent

SECTI ON 08 51 13 Page 6 l ar ger i n ar ea, t han t he t est ed wi ndow. Pr oposed wi ndows of a s i ze out s i de t hi s r ange r equi r e t est i ng t o eval uat e t hei r hazar d r at i ng. Test i ng may be by shockt ube or ar ena t est . The t est must be per f or med on t he ent i r e pr oposed wi ndow syst em, t o i ncl ude, but not be l i mi t ed t o, t he gl azi ng, i t s f r ami ng syst em, oper at i ng devi ces, and al l anchor age devi ces. Anchor age of t he wi ndow f r ame or subf r ame must r epl i cat e t he met hod of i nst al l at i on t o be used f or t he pr oj ect . The mi ni mum ai r bl ast l oadi ng par amet er s f or t he t est must be as f ol l ows: Peak posi t i ve pr essur e of 40 kPa and posi t i ve phase i mpul se of 285 kPa- msec. The hazar d r at i ng f or t he pr oposed wi ndow syst ems, as det er mi ned by t he r at i ng cr i t er i a of ASTM F1642/ F1642M, must not exceed t he " Ver y Low Hazar d" r at i ng ( i . e. t he " No Br eak" , " No Hazar d" , " Mi ni mal Hazar d" and " Ver y Low Hazar d" r at i ngs ar e accept abl e. " Low Hazar d" and " Hi gh Hazar d" r at i ngs ar e unaccept abl e) . Resul t s of wi ndow syst ems pr evi ousl y t est ed by t est pr ot ocol s ot her t han ASTM F1642/ F1642M may be accept ed pr ovi ded t he r equi r ed l oadi ng, hazar d l evel r at i ng, and si ze l i mi t at i ons st at ed her ei n ar e met .

1. 11. 3 Ai r I nf i l t r at i on

Ai r i nf i l t r at i on must not exceed t he amount est abl i shed by AAMA/ WDMA/ CSA 101/ I . S. 2/ A440 f or each wi ndow t ype.

1. 11. 4 Wat er Penet r at i on

Wat er penet r at i on must not exceed t he amount est abl i shed by AAMA/ WDMA/ CSA 101/ I . S. 2/ A440 f or each wi ndow t ype.

1. 11. 5 Ther mal Per f or mance

Non- r esi dent i al al umi num wi ndows ( i ncl udi ng f r ames and gl ass) must be cer t i f i ed by t he Nat i onal Fenest r at i on Rat i ng Counci l wi t h a whol e- wi ndow Sol ar Heat Gai n Coef f i c i ent ( SHGC) maxi mum of . 25 det er mi ned accor di ng t o

NFRC 200 pr ocedur es and a U- f act or maxi mum of . 50 Bt u/ hr - f t 2- F i n accor dance wi t h NFRC 100.

1. 11. 6 Sound At t enuat i on

The wi ndow uni t must have a mi ni mum STC of 34 wi t h t he wi ndow gl azed wi t h 1/ 2 i nch ai r space bet ween t wo pi eces of 1/ 4 i nch t hi ck gl ass when t est ed i n accor dance wi t h AAMA/ WDMA/ CSA 101/ I . S. 2/ A440 acoust i cal per f or mance (optional).

1. 12 QUALIFICATION

Wi ndow manuf act ur er must speci al i ze i n desi gni ng and manuf act ur i ng t he t ype of al umi num wi ndows speci f i ed i n t hi s sect i on, and have a mi ni mum of 5 year s of document ed successf ul exper i ence. Manuf act ur er must have t he f aci l i t i es capabl e of meet i ng cont r act r equi r ement s, s i ngl e- sour ce r esponsi bi l i t y and war r ant y.

1. 13 WARRANTY

Pr ovi de Manuf act ur er ' s st andar d per f or mance guar ant ees or war r ant i es t hat ext end beyond a 1 year per i od.

SECTI ON 08 51 13 Page 7

PART 2 PRODUCTS

2. 1 PRODUCT SUSTAI NABI LI TY CRI TERI A

For pr oduct s i n t hi s sect i on, wher e appl i cabl e and t o ext ent al l owed by per f or mance cr i t er i a, pr ovi de and document t he f ol l owi ng:

2. 1. 1 Recycl ed cont ent of Al umi num Wi ndows

Pr ovi de al umi num wi ndow f r ames meet i ng t he r ecycl ed cont ent r equi r ement s as st at ed wi t hi n t hi s sect i on and pr ovi de document at i on i n accor dance wi t h Sect i on 01 33 29 SUSTAI NABI LI TY REPORTI NG par agr aph RECYCLED CONTENT.

2. 2 WINDOWS

Pr ovi de pr i me wi ndows t hat compl y wi t h AAMA/ WDMA/ CSA 101/ I . S. 2/ A440 and t he r equi r ement s speci f i ed her ei n. I n addi t i on t o compl i ance wi t h AAMA/ WDMA/ CSA 101/ I . S. 2/ A440, wi ndow f r ami ng member s f or each i ndi v i dual l i ght of gl ass must not def l ect t o t he ext ent t hat def l ect i on per pendi cul ar t o t he gl ass l i ght exceeds L/ 175 of t he gl ass edge l engt h when subj ect ed t o uni f or m l oads at speci f i ed desi gn pr essur es. Pr ovi de St r uct ur al cal cul at i ons f or def l ect i on t o subst ant i at e compl i ance wi t h def l ect i on r equi r ement s. Pr ovi de wi ndows of t ypes, per f or mance cl asses, per f or mance gr ades, combi nat i ons, and si zes i ndi cat ed or speci f i ed. Pr ovi de al umi num wi ndow f r ames wi t h a mi ni mum r ecycl ed cont ent of 20 per cent . Desi gn wi ndows t o accommodat e har dwar e, gl ass, weat her st r i ppi ng, scr eens, and accessor i es t o be f ur ni shed. Each wi ndow must be a compl et e f act or y assembl ed uni t wi t h or wi t hout gl ass i nst al l ed. Di mensi ons shown ar e mi ni mum. Pr ovi de wi ndows wi t h i nsul at i ng gl ass and t her mal br eak necessar y t o achi eve a mi ni mum Condensat i on Resi st ance Fact or ( CRF) of 46 t o 50 when t est ed i n accor dance wi t h AAMA 1503.

2. 2. 1 Fi xed Wi ndows ( F)

Type F- AW40.

2. 2. 2 For ced Ent r y Resi st ant Wi ndows

I n addi t i on t o meet i ng t he r equi r ement s of AAMA/ WDMA/ CSA 101/ I . S. 2/ A440, wi ndows desi gnat ed f or r esi st ance t o f or ced ent r y must conf or m t o t he r equi r ement s of AAMA 1302. 4.

2. 2. 3 Gl ass and Gl azi ng

Mat er i al s ar e speci f i ed i n Sect i on 08 81 00 GLAZI NG.

2. 2. 4 Caul k i ng and Seal i ng

Ar e speci f i ed i n Sect i on 07 92 00 JOI NT SEALANTS.

2. 2. 5 Weatherstripping

AAMA/ WDMA/ CSA 101/ I . S. 2/ A440.

2. 3 FABRICATION

Fabr i cat i on of wi ndow uni t s must compl y wi t h AAMA/ WDMA/ CSA 101/ I . S. 2/ A440.

SECTI ON 08 51 13 Page 8

2. 3. 1 Pr ovi s i ons f or Gl azi ng

Desi gn wi ndows and r abbet s sui t abl e f or gl ass t hi ckness as i ndi cat ed on t he dr awi ngs. For mi ni mum ant i t er r or i sm wi ndows, at t ach gl azi ng t o i t s suppor t i ng f r ame usi ng st r uct ur al s i l i cone seal ant or adhesi ve gl azi ng t ape i n accor dance wi t h ASTM F2248. Desi gn sash f or out s i de gl azi ng and f or secur i ng gl ass wi t h met al beads, gl azi ng c l i ps, gl azi ng channel s, or gl azi ng compound.

2. 3. 2 Weatherstripping

Pr ovi de f or vent i l at i ng sect i ons of al l wi ndows t o ensur e a weat her - t i ght seal meet i ng t he i nf i l t r at i on r equi r ement s speci f i ed i n AAMA/ WDMA/ CSA 101/ I . S. 2/ A440. Pr ovi de easi l y r epl aceabl e f act or y- appl i ed weat her st r i ppi ng. Use mol ded vi nyl , mol ded or mol ded- expanded neopr ene or mol ded or expanded Et hyl ene Pr opyl ene Di ene Ter pol ymer ( EPDM) compr essi on- t ype weat her st r i ppi ng f or compr essi on cont act sur f aces. Use t r eat ed woven pi l e or wool , or pol ypr opyl ene or ny l on pi l e bonded t o nyl on f abr i c and met al or pl ast i c backi ng st r i p weat her st r i ppi ng f or s l i di ng sur f aces. Do no use neopr ene or pol yvi nyl chl or i de weat her st r i ppi ng wher e exposed t o di r ect sunl i ght .

2. 3. 3 Fasteners

Use wi ndow manuf act ur er ' s st andar d f or wi ndows, t r i m, and accessor i es.

Sel f - t appi ng sheet - met al scr ews ar e not accept abl e f or mat er i al mor e t han 1/ 16 i nch t hi ck.

2. 3. 4 Adhesives

Pr ovi de j oi nt seal ant s as speci f i ed i n Sect i on 07 92 00 JOI NT SEALANTS.

For i nt er i or appl i cat i on of j oi nt seal ant s, compl y wi t h appl i cabl e r egul at i ons r egar di ng r educed VOC' s, and as speci f i ed i n Sect i on 07 92 00

JOI NT SEALANTS.

2. 3. 5 Dr i ps and Weep Hol es

Pr ovi de cont i nuous dr i ps over heads of t op vent i l at or s. Wher e f i xed wi ndows adj oi n vent i l at or s, dr i ps must be cont i nuous acr oss t ops of f i xed wi ndows. Pr ovi de dr i ps and weep hol es as r equi r ed t o r et ur n wat er t o t he outside.

2. 3. 6 Combi nat i on Wi ndows

Wi ndows used i n combi nat i on must be f act or y assembl ed of t he same cl ass and gr ade. Wher e f act or y assembl y of i ndi v i dual wi ndows i nt o l ar ger uni t s i s l i mi t ed by t r anspor t at i on consi der at i ons, pr ef abr i cat e, mat ch mar k, t r anspor t , and f i el d assembl e.

2. 3. 7 Mul l i ons and Tr ansom Bar s

Pr ovi de mul l i ons bet ween mul t i pl e wi ndow uni t s t o r esi st t wo t i mes ( 2X) gl azi ng r esi st ance i n accor dance wi t h ASTM F2248 and ASTM E1300. Pr ovi de mul l i ons wi t h a t her mal br eak. Secur e mul l i ons and t r ansom bar s t o adj oi ni ng const r uct i on and wi ndow uni t s i n such a manner as t o per mi t expansi on and cont r act i on and t o f or m a weat her t i ght j oi nt . Pr ovi de mul l i on cover s on t he i nt er i or and ext er i or t o compl et el y c l ose exposed j oi nt s and r ecesses bet ween wi ndow uni t s and t o pr esent a neat appear ance.

SECTI ON 08 51 13 Page 9

2. 3. 8 Accessories

Pr ovi de wi ndows compl et e wi t h necessar y har dwar e, f ast eni ngs, c l i ps, f i ns, anchor s, gl azi ng beads, and ot her appur t enances necessar y f or compl et e i nst al l at i on and pr oper oper at i on. Fur ni sh ext r uded al umi num subf r ame r ecept or s and subsi l l wi t h each wi ndow uni t .

2. 3. 8. 1 Hardware

AAMA/ WDMA/ CSA 101/ I . S. 2/ A440. The i t em, t ype, and f unct i onal char act er i st i cs must be t he manuf act ur er ' s st andar d f or t he par t i cul ar wi ndow t ype. Pr ovi de har dwar e of sui t abl e desi gn and of suf f i c i ent st r engt h t o per f or m t he f unct i on f or whi ch i t i s used. Equi p al l oper at i ng vent i l at or s wi t h a l ock or l at chi ng devi ce whi ch can be secur ed f r om t he inside.

2. 3. 8. 2 Fasteners

Pr ovi de conceal ed anchor s of t he t ype r ecommended by t he wi ndow manuf act ur er f or t he speci f i c t ype of const r uct i on. Anchor s and f ast ener s must be compat i bl e wi t h t he wi ndow and t he adj oi ni ng const r uct i on. Pr ovi de a mi ni mum of t hr ee anchor s f or each j amb l ocat ed appr oxi mat el y 6 i nches f r om each end and at mi dpoi nt .

2. 3. 8. 3 Wi ndow Anchor s

Anchor i ng devi ces f or i nst al l i ng wi ndows must be made of al umi num, cadmi um- pl at ed st eel , st ai nl ess st eel , or z i nc- pl at ed st eel conf or mi ng t o

AAMA/ WDMA/ CSA 101/ I . S. 2/ A440.

2. 3. 9 Finishes

Exposed al umi num sur f aces must be f act or y f i ni shed wi t h an anodi c coat i ng.

Col or must be as speci f i f i ed i n 09 06 00 COLOR SCHEDULE. Al l wi ndows must have t he same f i ni sh.

2. 3. 9. 1 Anodi c Coat i ng

Cl ean exposed al umi num sur f aces and pr ovi de an anodi zed f i ni sh conf or mi ng to AA DAF45 and AAMA 611. Fi ni sh must be:

b. Ar chi t ect ur al Cl ass I ( 0. 7 mi l or t hi cker ) , desi gnat i on AA- M10- C22- A41, c l ear ( nat ur al ) anodi zed.

2. 4 THERMAL- BARRI ER WI NDOWS

Pr ovi de t her mal - bar r i er wi ndows, compl et e wi t h accessor i es and f i t t i ngs, wher e i ndi cat ed.

Speci f y mat er i al and const r uct i on except as f ol l ows:

a. Al umi num al l oy must be 6063- T6.

b. Fr ame const r uct i on, i ncl udi ng oper abl e sash, must be f act or y- assembl ed and f act or y- seal ed i nner and out er al umi num compl et el y separ at ed f r om met al - t o- met al cont act . Joi n assembl y by a cont i nuous, conceal ed, l ow conduct ance di v i der housed i n an i nt er l ocki ng ext r usi on of t he i nner f r ame. Met al f ast ener s, st r aps, or anchor s must not br i dge t he connect i on bet ween t he i nner and out er f r ame.

SECTI ON 08 51 13 Page 10

c. Oper at i ng har dwar e f or each sash must consi st of spr i ng- l oaded nyl on cushi on bl ocks and pi n l ocks desi gned t o l ock i n pr edet er mi ned locations.

d. Sash must be compl et el y separ at ed f r om met al - t o- met al cont act by means of woven- pi l e weat her st r i ppi ng, pl ast i c, or el ast omer i c separ at i on members.

e. Oper at i ng and st or m sash must be f act or y- gl azed wi t h t he t ype of gl ass i ndi cat ed and of t he qual i t y speci f i ed i n Sect i on 08 81 00 GLAZI NG.

2. 5 MULLIONS

Pr ovi de mul l i ons bet ween mul t i pl e- wi ndow uni t s wher e i ndi cat ed.

Pr ovi de pr of i l es f or mul l i ons and mul l i on cover s, r ei nf or ced as r equi r ed f or t he speci f i ed wi nd l oadi ng, and secur el y anchor ed t o t he adj oi ni ng const r uct i on. Mul l i on ext r usi on wi l l i nc l ude ser r at i ons or pocket s t o r ecei ve weat her st r i ppi ng, seal ant , or t ape at t he poi nt of cont act wi t h each wi ndow f l ange.

Mul l i on assembl y must i ncl ude al umi num wi ndow cl amps or br acket s scr ewed or bol t ed t o t he mul l i on and t he mul l i on cover .

Mul l i on cover must be scr ew- f ast ened t o t he mul l i on unl ess ot her wi se indicated.

Mul l i on r ei nf or c i ng member s must be f abr i cat ed of t he mat er i al s speci f i ed in AAMA/ WDMA/ CSA 101/ I . S. 2/ A440 and meet t he speci f i ed desi gn l oadi ng.

2. 6 WI NDOW CLEANERS' BOLTS

Pr ovi de wi ndow cl eaner s ' bol t s f or al l wi ndows 7 f eet or hi gher above f i ni shed gr ade, except f or wi ndows t hat can be r emoved and cl eaned f r om t he gr ound or f r om a l ower r oof l evel wi t hout t he use of an ext ensi on l adder .

Pr ovi de t wo bol t s f or each si ngl e wi ndow uni t and each f i xed gl ass uni t .

Locat e bol t s 44 i nches above t he wi ndow si l l .

Wi ndow cl eaner s ' bol t s must be doubl e- head t ype, AI SI Ser i es 300 cor r osi on- r esi st ant st eel , s i ze and desi gn compl yi ng wi t h I WCA I - 14. 1.

Cont act s i de of t he bol t s must be gr ound t o f i t f l at agai nst wi ndow j ambs.

Bol t s must be f act or y- or f i el d- at t ached bef or e wi ndows ar e set . Rei nf or ce backs of f r ames t o r ecei ve bol t s wi t h 1/ 4 by 6- i nch cor r osi on- r esi st ant st eel or al umi num pl at es bol t ed or wel ded t o t he f r ames at t he f act or y.

Speci al wal l anchor s must be pr ovi ded on f r ames at t he poi nt of bol t attachment.

PART 3 EXECUTI ON

3. 1 INSTALLATION

3. 1. 1 Met hod of I nst al l at i on

I nst al l i n accor dance wi t h t he wi ndow manuf act ur er ' s pr i nt ed i nst r uct i ons and det ai l s . Bui l d i n wi ndows as t he wor k pr ogr esses or i nst al l wi t hout f or c i ng i nt o pr epar ed wi ndow openi ngs. Set wi ndows at pr oper el evat i on, l ocat i on, and r eveal ; pl umb, squar e, l evel , and i n al i gnment ; and br ace, st r ut , and st ay pr oper l y t o pr event di st or t i on and mi sal i gnment . Pr ot ect

SECTI ON 08 51 13 Page 11 vent i l at or s and oper at i ng par t s agai nst accumul at i on of di r t and bui l di ng mat er i al s by keepi ng vent i l at or s t i ght l y c l osed and l ocked t o f r ame. Bed scr ews or bol t s i n s i l l member s, j oi nt s at mul l i ons, cont act s of wi ndows wi t h s i l l s , bui l t - i n f i ns, and subf r ames i n mast i c seal ant of a t ype r ecommended by t he wi ndow manuf act ur er . I nst al l and caul k wi ndows i n a manner t hat wi l l pr event ent r ance of wat er and wi nd. Fast en i nsect scr eens secur el y i n pl ace.

Any mat er i al s t hat show vi sual ev i dence of bi ol ogi cal gr owt h due t o t he pr esence of moi st ur e must not be i nst al l ed on t he bui l di ng pr oj ect .

3. 1. 2 Di ssi mi l ar Mat er i al s

Wher e al umi num sur f aces ar e i n cont act wi t h, or f ast ened t o masonr y, concr et e, wood, or di ssi mi l ar met al s, except st ai nl ess st eel or z i nc, pr ot ect t he al umi num sur f ace f r om di ssi mi l ar mat er i al s as r ecommended i n t he Appendi x t o AAMA/ WDMA/ CSA 101/ I . S. 2/ A440. Do not coat sur f aces i n cont act wi t h seal ant s af t er i nst al l at i on wi t h any t ype of pr ot ect i ve material.

3. 1. 3 Anchor s and Fast eni ngs

Make pr ovi s i on f or secur i ng uni t s t o each ot her , t o masonr y, and t o ot her adj oi ni ng const r uct i on. Wi ndows i nst al l ed i n masonr y wal l s must have head and j amb member s desi gned t o r ecess i nt o masonr y wal l not l ess t han 7/ 16 inch.

3. 1. 4 Adj ust ment s Af t er I nst al l at i on

Af t er i nst al l at i on of wi ndows and compl et i on of gl azi ng and f i el d pai nt i ng, adj ust al l vent i l at or s and har dwar e t o oper at e smoot hl y and t o pr ovi de weat her t i ght seal i ng when vent i l at or s ar e c l osed and l ocked. Lubr i cat e har dwar e and oper at i ng par t s as necessar y. Ver i f y t hat pr oduct s ar e pr oper l y i nst al l ed, connect ed, and adj ust ed.

3. 2 CLEANING

Cl ean i nt er i or and ext er i or sur f aces of wi ndow uni t s of mor t ar , pl ast er , pai nt spat t er i ng spot s, and ot her f or ei gn mat t er t o pr esent a neat appear ance, t o pr event f oul i ng of weat her i ng sur f aces and weat her - st r i ppi ng, and t o pr event i nt er f er ence wi t h t he oper at i on of har dwar e. Repl ace al l s t ai ned, di scol or ed, or abr aded wi ndows t hat cannot be r est or ed t o t hei r or i gi nal condi t i on wi t h new wi ndows.

- - End of Sect i on - -

SECTI ON 08 51 13 Page 12

SECTI ON 08 71 00

DOOR HARDWARE

PART 1 GENERAL

1. 1 REFERENCES

The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o i n t he t ext by t he basi c desi gnat i on onl y.

ASTM I NTERNATI ONAL ( ASTM)

ASTM E283 ( 2004; R 2012) Det er mi ni ng t he Rat e of Ai r Leakage Thr ough Ext er i or Wi ndows, Cur t ai n Wal l s, and Door s Under Speci f i ed Pr essur e Di f f er ences Acr oss t he Speci men

ASTM F883 ( 2013) Padl ocks

BUI LDERS HARDWARE MANUFACTURERS ASSOCI ATI ON ( BHMA)

ANSI / BHMA A156. 1 ( 2016) But t s and Hi nges

ANSI / BHMA A156. 10 ( 2017) Power Oper at ed Pedest r i an Door s

ANSI / BHMA A156. 13 ( 2017) Mor t i se Locks & Lat ches Ser i es 1000

ANSI / BHMA A156. 14 ( 2013) Sl i di ng and Fol di ng Door Har dwar e

ANSI / BHMA A156. 15 ( 2015) Rel ease Devi ces Cl oser Hol der , El ect r omagnet i c and El ect r omechani cal

ANSI / BHMA A156. 16 ( 2013) Auxi l i ar y Har dwar e

ANSI / BHMA A156. 17 ( 2014) Sel f Cl osi ng Hi nges & Pi vot s

ANSI / BHMA A156. 18 ( 2016) Mat er i al s and Fi ni shes

ANSI / BHMA A156. 19 ( 2013) Power Assi st & Low Ener gy Power Oper at ed Door s

ANSI / BHMA A156. 2 ( 2017) Bor ed and Pr eassembl ed Locks and Latches

ANSI / BHMA A156. 21 ( 2014) Thr eshol ds

ANSI / BHMA A156. 22 ( 2017) Door Gasket i ng and Edge Seal Syst ems

ANSI / BHMA A156. 23 ( 2010) El ect r omagnet i c Locks

ANSI / BHMA A156. 24 ( 2012) Del ayed Egr ess Locki ng Syst ems

ANSI / BHMA A156. 25 ( 2013) El ect r i f i ed Locki ng Devi ces

SECTI ON 08 71 00 Page 1

ANSI / BHMA A156. 26 ( 2012) Cont i nuous Hi nges

ANSI / BHMA A156. 27 ( 2011) Power and Manual Oper at ed Revol v i ng Pedest r i an Door s

ANSI / BHMA A156. 29 ( 2012) Exi t Locks, Exi t Al ar ms, Al ar ms f or Exi t Devi ces

ANSI / BHMA A156. 3 ( 2014) Exi t Devi ces

ANSI / BHMA A156. 31 ( 2013) El ect r i c St r i kes and Fr ame Mount ed Actuators

ANSI / BHMA A156. 36 ( 2010) Auxi l i ar y Locks

ANSI / BHMA A156. 4 ( 2013) Door Cont r ol s - Cl oser s

ANSI / BHMA A156. 5 ( 2014) Cyl i nder and I nput Devi ces f or Locks

ANSI / BHMA A156. 6 ( 2015) Ar chi t ect ur al Door Tr i m

ANSI / BHMA A156. 7 ( 2016) Templ at e Hi nge Di mensi ons

ANSI / BHMA A156. 8 ( 2015) Door Cont r ol s - Over head St ops and Holders

NATI ONAL FI RE PROTECTI ON ASSOCI ATI ON ( NFPA)

NFPA 101 ( 2018; TI A 18- 1) Li f e Saf et y Code

NFPA 252 ( 2017) St andar d Met hods of Fi r e Test s of Door Assembl i es

NFPA 70 ( 2017; ERTA 1- 2 2017; TI A 17- 1; TI A 17- 2;

TI A 17- 3; TI A 17- 4; TI A 17- 5; TI A 17- 6;

TI A 17- 7; TI A 17- 8; TI A 17- 9; TI A 17- 10;

TI A 17- 11; TI A 17- 12; TI A 17- 13; TI A

17- 14) Nat i onal El ect r i cal Code

NFPA 72 ( 2016) Nat i onal Fi r e Al ar m and Si gnal i ng Code

NFPA 80 ( 2016; TI A 16- 1) St andar d f or Fi r e Door s and Ot her Openi ng Pr ot ect i ves

STEEL DOOR I NSTI TUTE ( SDI / DOOR)

SDI / DOOR A250. 8 ( 2003; R2008) Recommended Speci f i cat i ons f or St andar d St eel Door s and Fr ames

U. S. NATI ONAL ARCHI VES AND RECORDS ADMI NI STRATI ON ( NARA)

36 CFR 1191 Amer i cans wi t h Di sabi l i t i es Act ( ADA) Accessi bi l i t y Gui del i nes f or Bui l di ngs and Faci l i t i es; Ar chi t ect ur al Bar r i er s Act ( ABA) Accessi bi l i t y Gui del i nes

SECTI ON 08 71 00 Page 2

UNDERWRI TERS LABORATORI ES ( UL)

UL Bl d Mat Di r ( updat ed cont i nuousl y onl i ne) Bui l di ng Mat er i al s Di r ect or y

1. 2 SUBMITTALS

Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" desi gnat i on;

submi t t al s not havi ng a " G" desi gnat i on ar e f or i nf or mat i on onl y. When used, a desi gnat i on f ol l owi ng t he " G" desi gnat i on i dent i f i es t he of f i ce t hat wi l l r evi ew t he submi t t al f or t he Gover nment . Submi t t al s wi t h an " S" ar e f or i ncl usi on i n t he Sust ai nabi l i t y eNot ebook, i n conf or mance wi t h Sect i on 01 33 29 SUSTAI NABI LI TY REPORTI NG. Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00 SUBMI TTAL PROCEDURES:

SD- 02 Shop Dr awi ngs

Manuf act ur er ' s Det ai l Dr awi ngs; G

Ver i f i cat i on of Exi st i ng Condi t i ons; G

Har dwar e Schedul e; G

Keyi ng Syst em; G

SD- 03 Pr oduct Dat a

Har dwar e I t ems; G

SD- 08 Manuf act ur er ' s I nst r uct i ons

Installation

SD- 10 Oper at i on and Mai nt enance Dat a

Har dwar e Schedul e I t ems, Dat a Package 1; G

SD- 11 Cl oseout Submi t t al s

Key Bi t t i ng

1. 3 SHOP DRAWI NGS

Submi t manuf act ur er ' s det ai l dr awi ngs i ndi cat i ng al l har dwar e assembl y component s and i nt er f ace wi t h adj acent const r uct i on. Base shop dr awi ngs on ver i f i ed f i el d measur ement s and i ncl ude ver i f i cat i on of exi st i ng condi t i ons.

1. 4 PRODUCT DATA

I ndi cat e f i r e- r at i ngs at appl i cabl e component s. Pr ovi de document at i on of ABA/ ADA accessi bi l i t y compl i ance of appl i cabl e component s, as r equi r ed by 36 CFR 1191 Appendi x D - Techni cal .

1. 5 HARDWARE SCHEDULE

Pr epar e and submi t har dwar e schedul e i n t he f ol l owi ng f or m:

SECTI ON 08 71 00 Page 3

Hardware Item

Quantity Size Reference Publi-cation Type No.

Finish Mfr Name and Catalog No.

Key Control Symbols

UL

Mark (If fire-rated and listed)

BHMA

Finish Desig-nation

I n addi t i on, submi t har dwar e schedul e dat a package 1 i n accor dance wi t h Sect i on 01 78 23 OPERATI ON AND MAI NTENANCE DATA.

1. 6 KEY BI TTI NG CHART REQUI REMENTS

1. 6. 1 Requirements

Submi t key bi t t i ng char t s t o t he Cont r act i ng Of f i cer pr i or t o compl et i on of t he wor k. I ncl ude:

a. Compl et e l i s t i ng of al l keys ( e. g. AA1 and AA2) .

b. Compl et e l i s t i ng of al l key cut s ( AA1- 123456, AA2- 123458) .

c. Tabul at i on showi ng whi ch key f i t s whi ch door .

d. Copy of f l oor pl an showi ng door s and door number s.

e. Li st i ng of 20 per cent mor e key cut s t han ar e pr esent l y r equi r ed i n each mast er syst em.

1. 7 QUALI TY ASSURANCE

1. 7. 1 Har dwar e Manuf act ur er s and Modi f i cat i ons

Pr ovi de, as f ar as f easi bl e, l ocks, hi nges, pi vot s, and c l oser s of one l ock, hi nge, pi vot , or c l oser manuf act ur er ' s make. Modi f y har dwar e as necessar y t o pr ovi de f eat ur es i ndi cat ed or speci f i ed.

1. 7. 2 Key Shop Dr awi ngs Coor di nat i on Meet i ng

Pr i or t o t he submi ssi on of t he key shop dr awi ng, t he Cont r act i ng Of f i cer , Cont r act or , Door Har dwar e Subcont r act or , usi ng Act i v i t y and Base Locksmi t h must meet t o di scuss and coor di nat e key r equi r ement s f or t he f aci l i t y .

1. 8 DELI VERY, STORAGE, AND HANDLI NG

Del i ver har dwar e i n or i gi nal i ndi v i dual cont ai ner s, compl et e wi t h necessar y appur t enances i ncl udi ng f ast ener s and i nst r uct i ons. Mar k each i ndi v i dual cont ai ner wi t h i t em number as shown on har dwar e schedul e. Del i ver per manent keys and r emovabl e cor es t o t he Cont r act i ng Of f i cer , ei t her di r ect l y or by cer t i f i ed mai l . Del i ver const r uct i on mast er keys wi t h t he locks.

PART 2 PRODUCTS

2. 1 TEMPLATE HARDWARE

Har dwar e appl i ed t o met al or t o pr ef i ni shed door s must be manuf act ur ed

SECTI ON 08 71 00 Page 4 usi ng a t empl at e. Pr ovi de t empl at es t o door and f r ame manuf act ur er s i n accor dance wi t h ANSI / BHMA A156. 7 f or t empl at e hi nges. Coor di nat e har dwar e i t ems t o pr event i nt er f er ence wi t h ot her har dwar e.

2. 2 HARDWARE FOR FI RE DOORS AND EXI T DOORS

Pr ovi de al l har dwar e necessar y t o meet t he r equi r ement s of NFPA 72 f or door alarms, NFPA 80 f or f i r e door s, NFPA 101 f or exi t door s, NFPA 252 f or f i r e t est s of door assembl i es, ABA/ ADA accessi bi l i t y r equi r ement s, and al l ot her r equi r ement s i ndi cat ed, even i f such har dwar e i s not speci f i cal l y ment i oned i n par agr aph HARDWARE SCHEDULE. Pr ovi de Under wr i t er s Labor at or i es, I nc. l abel s f or such har dwar e i n accor dance wi t h UL Bl d Mat Di r or equi val ent l abel s i n accor dance wi t h anot her t est i ng l abor at or y appr oved i n wr i t i ng by t he Cont r act i ng Of f i cer .

2. 3 HARDWARE I TEMS

Cl ear l y and per manent l y mar k wi t h t he manuf act ur er ' s name or t r ademar k, hi nges, pi vot s, l ocks, l at ches, exi t devi ces, bol t s and cl oser s wher e t he i dent i f y i ng mar k i s v i s i bl e af t er t he i t em i s i nst al l ed. For c l oser s wi t h cover s, t he name or t r ademar k may be beneat h t he cover . Coor di nat e el ect r i f i ed door har dwar e component s wi t h cor r espondi ng component s speci f i ed i n Di v i s i on 28 ELECTRONI C SECURI TY SYSTEMS ( ESS) .

2. 3. 1 Hinges

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 1. Pr ovi de hi nges t hat ar e 4- 1/ 2 by 4- 1/ 2 i nch unl ess ot her wi se i ndi cat ed. Const r uct l oose pi n hi nges f or i nt er i or door s and r ever se- bevel ext er i or door s so t hat pi ns ar e non- r emovabl e when door i s c l osed. Ot her ant i - f r i c t i on bear i ng hi nges may be pr ovi ded i n l i eu of bal l bear i ng hi nges.

2. 3. 2 Cont i nuous Hi nges

Wher e cont i nuous hi nges ar e r equi r ed, pr ovi de i n accor dance wi t h

ANSI / BHMA A156. 26.

2. 3. 3 Pivots

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 17.

2. 3. 4 Spr i ng Hi nges

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 17.

2. 3. 5 Locks and Lat ches

2. 3. 5. 1 Mor t i se Locks and Lat ches

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 13, Ser i es 1000, Oper at i onal Gr ade 1, Secur i t y Gr ade 2. Pr ovi de mor t i se l ocks wi t h escut cheons not l ess t han 7 by 2- 1/ 4 i nch wi t h a bushi ng at l east 1/ 4 i nch l ong. Cut escut cheons t o f i t cy l i nder s and pr ovi de t r i m i t ems wi t h st r ai ght , bevel ed, or smoot hl y r ounded si des, cor ner s, and edges. Pr ovi de knobs and r oses of mor t i se l ocks wi t h scr ewl ess shanks and no exposed scr ews.

2. 3. 5. 2 Bor ed Locks and Lat ches

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 2, Ser i es 4000, Gr ade 1.

SECTI ON 08 71 00 Page 5

2. 3. 5. 3 Hospi t al Lat ches

Push- pul l l at ch set s i mi l ar and equal t o Gl ynn- Johnson HL6, 1/ 2 i nch t hr ow, 2- 3/ 4 i nch backset , t o f i t 161 cut out . Cover appr oxi mat el y 2- 1/ 2 by 5- 1/ 2 i nch, handl e appr oxi mat el y 1- 1/ 2 by 4- 1/ 2 i nch, pr oj ect i on appr oxi mat el y 2- 1/ 2 i nch, cover s and handl es of st ai nl ess st eel , BHMA 630 f i ni sh, engr aved " PUSH" and " PULL" on handl es, push handl e poi nt i ng up, pul l handl e poi nt i ng down.

2. 3. 5. 4 Auxi l i ar y Locks

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 36, Gr ade 1.

2. 3. 5. 5 Combi nat i on Locks

Heavy- dut y, mechani cal combi nat i on l ockset wi t h f i ve push but t ons, st andar d s i zed knobs, 3/ 4 i nch deadl ocki ng l at ch, 2- 3/ 4 i nch backset . Locks t o oper at e by pr essi ng t wo or mor e of t he but t ons i n uni son or i ndi v i dual l y i n t he pr oper sequence. I nsi de knob oper at es t he l at ch. Pr ovi de a keyed cyl i nder on t he i nt er i or t o per mi t set t i ng t he combi nat i on. Pr ovi de a keyed r emovabl e cor e cyl i nder on t he ext er i or t o per mi t bypassi ng t he combi nat i on.

2. 3. 6 Exi t Devi ces

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 3, Gr ade 1. Pr ovi de adj ust abl e st r i kes f or r i m t ype and ver t i cal r od devi ces. Pr ovi de open back st r i kes f or pai r s of door s wi t h mor t i se and ver t i cal r od devi ces. Pr ovi de t ouch bar s i n l i eu of convent i onal cr ossbar s and ar ms. Pr ovi de escut cheons not l ess t han 7 by 2- 1/ 4 i nch.

2. 3. 7 Exi t Locks Wi t h Al ar m

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 3 and ANSI / BHMA A156. 29, Type E0431 ( wi t h f ul l wi dt h hor i zont al act uat i ng bar ) f or s i ngl e door s; Type E0431 ( wi t h act uat i ng bar ) or E0471 ( wi t h act uat i ng bar and t op and bot t om bol t s, bot h l eaves act i ve) f or pai r s of door s, unl ess ot her wi se speci f i ed.

Pr ovi de door al ar ms i nt egr at ed wi t h t he f i r e al ar m syst em i n accor dance with NFPA 72.

2. 3. 8 Cyl i nder s and Cor es

Pr ovi de cyl i nder s and cor es f or new l ocks, i ncl udi ng l ocks pr ovi ded under ot her sect i ons of t hi s speci f i cat i on. Pr ovi de cyl i nder s and cor es wi t h seven pi n t umbl er s. Pr ovi de cyl i nder s f r om t he pr oduct s of one manuf act ur er , and pr ovi de cor es f r om t he pr oduct s of one manuf act ur er . Ri m cyl i nder s, mor t i se cyl i nder s, and knobs of bor ed l ockset s have i nt er changeabl e cor es whi ch ar e r emovabl e by speci al cont r ol keys. St amp each i nt er changeabl e cor e wi t h a key cont r ol symbol i n a conceal ed pl ace on t he cor e.

2. 3. 9 Push But t on Mechani sms

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 5, Gr ade 1.

2. 3. 10 El ect r i f i ed Har dwar e

Compl y wi t h t he r equi r ement s of NFPA 70 f or wi r i ng of el ect r i f i ed har dwar e.

SECTI ON 08 71 00 Page 6

2. 3. 10. 1 El ect r i c St r i kes and Fr ame Mount ed Act uat or s

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 31, Gr ade 1. Pr ovi de el ect r i c st r i kes and act uat or s as r equi r ed t o meet oper at i onal r equi r ement s.

Pr ovi de el ect r i c st r i kes t hat r emai n mai nt ai ned dur i ng power f ai l ur e.

Pr ovi de a separ at e power suppl y f or el ect r i c st r i kes, ot her l ocki ng devi ces and anci l l ar y par t s. Pr ovi de bat t er y backup f or cont i nued oper at i on dur i ng power f ai l ur e. Pr ovi de st r i kes and act uat or s wi t h a mi ni mum openi ng f or ce of 2300 pounds.

Pr ovi de f aci l i t y i nt er f ace devi ces t hat use di r ect cur r ent ( dc) power t o ener gi ze t he sol enoi ds. Pr ovi de el ect r i c st r i kes and act uat or s t hat i ncor por at e end- of - l i ne r esi st or s t o f aci l i t at e l i ne super vi s i on by t he syst em. I f not i ncor por at ed i nt o t he el ect r i c st r i ke or l ocal cont r ol l er , pr ovi de met al ox i de r esi st or s ( MOVs) t o pr ot ect t he cont r ol l er f r om r ever se cur r ent sur ges.

2. 3. 10. 1. 1 Solenoid

Pr ovi de act uat i ng sol enoi d f or st r i kes and act uat or s t hat ar e r at ed f or cont i nuous dut y, cannot di ssi pat e mor e t han 12 Wat t s and must oper at e on 12 or 24 Vol t s dc. I nr ush cur r ent cannot exceed 1 amper e and t he hol di ng cur r ent cannot be gr eat er t han 500 mi l l i amper es. Act uat i ng sol enoi d must move f r om f ul l y secur e t o f ul l y open posi t i ons i n l ess t han 500 milliseconds.

2. 3. 10. 1. 2 Si gnal Swi t ches

Pr ovi de st r i kes and act uat or s wi t h s i gnal swi t ches t o i ndi cat e t o t he syst em when t he bol t i s not engaged or t he st r i ke mechani sm i s unl ocked.

Si gnal swi t ches must r epor t a f or ced ent r y t o t he syst em.

2. 3. 10. 1. 3 Tamper Resi st ance

Pr ovi de st r i ke guar ds t hat pr event t amper i ng wi t h t he l at ch bol t of t he l ocki ng har dwar e or t he l at ch bol t keeper of t he el ect r i c st r i ke. St r i ke guar ds t o bol t t hr ough t he door usi ng t amper r esi st ant scr ews. Pr ovi de st r i ke guar ds made of 1/ 8 i nch t hi ck br ass and t hat ar e 11- 1/ 14 i nch hi gh by 1- 5/ 8 i nch wi de, wi t h a mi ni mum 5/ 32 i nch wi de of f set .

2. 3. 10. 1. 4 Coordination

Pr ovi de el ect r i c st r i kes and act uat or s of a s i ze, wei ght and pr of i l e compat i bl e wi t h each speci f i ed door f r ame. Fi el d ver i f y i nst al l at i on c l ear ances pr i or t o pr ocur ement .

2. 3. 10. 1. 5 Mount i ng Met hod

Pr ovi de el ect r i c st r i kes and act uat or s sui t abl e f or use wi t h s i ngl e and doubl e door s, wi t h mor t i se or r i m t ype har dwar e speci f i ed, and f or r i ght or l ef t hand mount i ng as speci f i ed. I n doubl e door i nst al l at i ons, l ocat e t he l ock i n t he act i ve l eaf and moni t or t he f i xed l eaf .

2. 3. 10. 2 El ect r i f i ed Mor t i se Locks

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 25, Gr ade 1. Pr ovi de el ect r i f i ed mor t i se l ocks t hat r emai n mai nt ai ned dur i ng power f ai l ur e. Pr ovi de f aci l i t y i nt er f ace devi ces t hat use dc power t o ener gi ze sol enoi ds.

SECTI ON 08 71 00 Page 7

Pr ovi de sol enoi ds, r esi st er s, and s i gnal swi t ches i n accor dance wi t h par agr aph ELECTRI C STRI KES AND FRAME MOUNTED ACTUATORS. Locks r equi r ed f or f i r e door s shal l be l i s t ed by Under wr i t er s Labor at or i es. Al l l ockset f unct i ons shal l be manuf act ur ed i n a s i ngl e s i zed case f or med f r om 12 gauge st eel mi ni mum. The case shal l be c l osed on al l s i des and back. The l ockset shal l have a f i el d- adj ust abl e, bevel ed ar mor ed f r ont , wi t h a 0. 125” t hi ckness mi ni mum. The l ockset shal l be 2- 3/ 4” backset , st andar d, wi t h a one- pi ece 3/ 4” t hr ow ant i - f r i c t i on st ai nl ess st eel l at chbol t . The deadbol t shal l be a f ul l 1” t hr ow made of st ai nl ess st eel and have 2 har dened st eel r ol l er i nser t s. Al l s t r i kes shal l be non- handed wi t h a cur ved l i p. To i nsur e pr oper al i gnment , al l t r i m, knobs, or l ever s, shal l be t hr u- bol t ed and f ul l y i nt er changeabl e bet ween r ose and escut cheon desi gns.

2. 3. 10. 2. 1 Power Tr ansf er Hi nges

Pr ovi de power t r ansf er hi nges wi t h each el ect r i f i ed l ock t hat r out e power and moni t or i ng s i gnal s f r om t he l ockset t o t he door f r ame. Coor di nat e power t r ansf er hi nges wi t h door f r ames.

2. 3. 10. 3 Car d Reader s and Keypad Access Cont r ol Har dwar e

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 5 and ANSI / BHMA A156. 25, Gr ade 1 component s. Pr ovi de devi ces t hat ar e t amper al ar med, t amper and vandal r esi st ant , sol i d st at e, and do not cont ai n el ect r oni cs whi ch coul d compr omi se t he access cont r ol subsyst em shoul d t he subsyst em be at t acked.

Pr ovi de sur f ace, semi - f l ush, pedest al , or weat her pr oof mount abl e devi ces as speci f i ed f or each i ndi v i dual l ocat i on. Each devi ce t o cont ai n a v i sual di spl ay, ei t her mount ed on t he f ace, or on an i nt egr al par t of t he devi ce, t o i ndi cat e access or exi t r equest pr ocessi ng, r equest appr oval , and r equest deni al . Pr ovi de pr oxi mi t y t ype car d r eader s capabl e of r eadi ng pr oxi mi t y t ype access cont r ol car ds. Pr ovi de keypads t hat cont ai n an i nt egr al 12- di gi t t act i l e keyboar d wi t h di gi t s ar r anged i n numer i cal or der .

Pr ovi de keypads t hat ar e a st andal one devi ce or i nt egr at ed i nt o t he car d r eader . Coor di nat e access cont r ol har dwar e wi t h cor r espondi ng devi ces and syst ems speci f i ed i n Di v i s i on 28 ELECTRONI C SECURI TY SYSTEMS ( ESS) .

2. 3. 10. 4 Power Oper at ed Pedest r i an Door Har dwar e

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 10, Gr ade 1.

2. 3. 10. 5 Rel ease Devi ces

I n accor dance wi t h ANSI / BHMA A156. 15, Gr ade 1.

2. 3. 10. 5. 1 Cl oser Hol der s

Pr ovi de door mount ed c l oser hol der devi ces connect ed by i nt egr al r el easi ng t o f i r e det ect i ng devi ces.

2. 3. 10. 5. 2 Rel ease Devi ces

Pr ovi de wal l or door mount ed El ect r omagnet i c r el ease devi ces connect ed t o f i r e det ect i ng devi ces.

2. 3. 10. 6 Power Assi st and Low Ener gy Power Oper at ed Door s

Pr ovi de i n accor dance wi t h ANSI /…