Drawings_(Part_8_of_9).pdf

PDF 11 MB Posted

Attached to
FY19 RRAD General Purpose Warehouse Federal contract opportunity
Solicitation number
W9126G19B0007
Issued by
Department of the Army Corps of Engineers Engineering District Fort Worth

About this file

Drawings Part 8 of 9

View the file

Other files for this federal contract opportunity

Other files attached to FY19 RRAD General Purpose Warehouse, newest first.
File Type Posted
C1_SF_1409_Abstract_of_Offerors.pdf PDF
A7_Amendment_5.pdf PDF
A7_Amendment_4.pdf PDF
Amendment_3.pdf PDF
Site_Visit.pdf PDF
A7_Amendment_2.pdf PDF
A10_FF&E_Package_(GPW)_FINAL.pdf PDF
B3_Amendment_1.pdf PDF
FFE_Package_(GPW)_FINAL.pdf PDF
Drawings_(Part_9_of_9).pdf PDF
Drawings_(Part_3_of_9).pdf PDF
Drawings_(Part_7_of_9).pdf PDF
Drawings_(Part_1_of_9).pdf PDF
Drawings_(Part_2_of_9).pdf PDF
Drawings_(Part_5_of_9).pdf PDF
Drawings_(Part_6_of_9).pdf PDF
Drawings_(Part_4_of_9).pdf PDF
B3_W9126G19B0007_(Part_3_of_4).pdf PDF
B3_W9126G19B0007_(Part_1_of_4).pdf PDF
B3_W9126G19B0007_(Part_2_of_4).pdf PDF
B3_W9126G19B0007_(Part_4_of_4).pdf PDF
Show all 21

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TYPICAL LATERAL BRACING DETAIL FOR SUSPENDED GYPSUM

BOARD CEILING SYSTEM

8 GA. MIN. DIA

STL VERT. WIRE SPACED

48" O.C. MAX.

HANGER WIRE INSIDE OF

COMPRESSION STRUT TO

HAVE 4 TIGHT TURNS.

COMPRESSION STRUT TO

BE A 1/2" CONDUIT.

45 SPLAY STL WIRE

MIN. 10 GA. DIA.

ATTACHED TO 1 1/2" CHANNEL

& SPLAYED IN 4 DIRECTIONS.

(SEE NOTES 1, 2.)

3 TURNS MIN. IN

MAX. 1 1/2" TYP.

16 GA. COLD-ROLLED STL

1 1/2" CHANNELS SPACED

48" O.C. MAX.

20 GA. ROLL-FORMED STL

7/8" HAT CHANNELS SPACED

24" O.C. MAX.2" MAX.

TYPICAL LATERAL BRACING DETAIL FOR SUSPENDED

ACOUSTICAL CEILING SYSTEM

8 GA. MIN. DIA

STL VERT. WIRE SPACED

48" O.C. MAX.

HANGER WIRE INSIDE OF

COMPRESSION STRUT TO

HAVE 4 TIGHT TURNS.

COMPRESSION STRUT TO

BE A 1/2" CONDUIT.

MAIN RUNNER

CROSS TEE

2" MAX.

3 TURNS MIN. IN

MAX. 1 1/2" TYP.

45 SPLAY STL WIRE

MIN 10 GA. DIA.

ATTACHED TO 1 1/2" TEE

& SPLAYED IN 4 DIRECTIONS.

(SEE NOTES 1, 2.)

SUSPENDED ACOUSTICAL CEILING SYSTEM

45 45

6'-0"

MAX.

4"

MAX.

4"

MAX.

SUSP. ACST. CLG TILE

CROSS RUNNER

HANGER WIRE

METAL WALL ANGLE FASTENED

PER SUSP. CLG SYSTEM MFR'S

RECOMMENDATIONS

MAIN RUNNERS

AT 48" O.C.

SE

E

RO

OM

F

IN

IS

H

SC

HE

DU

LE

FO

R

EL

EV

O F

CL

G

A.

F.

F.

LATERAL BRACING

GENERAL NOTES

1. PROVIDE SPLACE BRACING AT 12'-0" OC MAXIMUM IN EACH DIRECTION WITH THE FIRST POINT WITHIN 6'-0" OF EACH

PERIMETER WALL.

2. CEILING AREA OF 144 SQUARE FEET OR LESS SURROUNDED BY WALLS WHICH CONNECT TO THE STRUCTURE SHALL NOT

REQUIRE SPLAYED WIRES.

3. SEALANT SHALL BE A POLYISOBUTYLENE-BASED OR ISOPRENE-ISOBUTYLENE-BASED PRESSURE-SENSITIVE TAPE OR

BEAD.

4. SEISMIC RESTRAINTS SHALL COMPLY WITH INTERNATIONAL BUILDING CODE.

SEE PARTITION TYPES

SUSPENDED GYPSUM BOARD CEILING SYSTEM

45 45

6'-0"

MAX.

4"

MAX.

4"

MAX.

1" 1"

HANGER WIRE

16 GA. COLD-ROLLED STL

1 1/2" CHANNELS SPACED

48" O.C. MAX.

20 GA. ROLL-FORMED STL

7/8" HAT CHANNELS SPACED

24" O.C. MAX.

5/8" TYPE X. GYP. BD.

SE

E

RE

FL

EC

TE

D

CE

ILI

NG

P

LA

N

FO

R

EL

EV

O

F

CL

G A.

F.

F.

13/8" x 7/8" x 22 GA.

GALV. STL ANGLE FASTENED

AT 16" O.C.

SEE WALL TYPES

HANGER WIRE

LATERAL BRACING

5/8" TYPE X. GYP. BD.

3/8" JOINT SEALED W/

SEALANT. ADHERE SEALANT TO

VERTICAL LEG OF EDGE ANGLE

BEFORE GYP. BD. IS INSTALLED.

(SEE NOTE 3)

SUSPENDED GYPSUM BOARD CEILING AT

MECHANICAL GRILLE/REGISTER DETAIL

SUSP. CLG SYSTEM HANGER DUCT (SEE MECH. FOR SIZE

AND SUSPENSION SYSTEM)

1/2" x 16 GA. GALV. STL FRAMING AT BOTH SIDES OF EA. MECH

GRILLE/REGISTER

1/2" x 16 GA. GALV. STL FRAMING AT BOTH SIDES OF EA.

MECH GRILLE/REGISTER

20 GA. ROLL-FORMED STL7/8" HAT CHANNELS SPACED

24" O.C. MAX.

GRILLE/REGISTER

SEE MECH.

5/8" TYPE X. GYP. BD. GYP. BD EDGE TRIM ALL

ROUND OPG.

SUSPENDED GYPSUM BOARD

CEILING AT LIGHTING FIXTURE

DETAIL

SUSP. CLG SYSTEM HANGER

GYP. BD EDGE TRIM ALL

ROUND OPG.

20 GA. ROLL-FORMED STL 7/8" HAT CHANNELS SPACED

24" O.C. MAX.

1/2" x 16 GA. GALV. STL FRAMING AT BOTH SIDES OF EA. LIGHT

FIXTURE

1/2" x 16 GA. GALV. STL FRAMING AT BOTH SIDES OF EA. LIGHT

FIXTURE

5/8" TYPE X. GYP. BD.

RECESSED LIGHTING FIXTURE AT ALL SUSP. CEILING SYSTEMS

SHALL HAVE SEISMIC RESTRAIINTS. (SEE ELEC.)

FINISHED GYP. BD.

CEILING

FLUSH TRIMLESS

ACCESS PANEL

MOUNTING FRAME

PLAN VIEW

CEILING FRAME

CHANNEL

MOUNTING FRAME

ANCHORED SECURELY

TO FRAME

FINISHED GYP. BD.

CEILING

ACCESS PANEL ANCHORED

SECURELY TO ANGLE-PAINT

TO MATCH CEILING

REQUIRED

SIZE AS

SEE PLANS

FOR LOCATIONS AND SIZING SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra wn b y:

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e:

C on tra ct

N o.

So lic ita tio n N o.

U .S

. A R

M Y

EN

G

IN

EE

R D

IS

TR

IC

T, C

O R

PS

O

F

EN

G

IN

EE

R

S

FO

R T

W O

R

TH

, T

EX

AS

R ev ie we d by

US Army Corps of Engineers ®

D

C

B

A

PL

O

T

SC

AL

E:

PL

O

T D

AT

E:

R ev

Sy m bo l

D es cr ip tio n

Tr ac ki ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H As in di ca te d

R E D

RI

VE

R A R

M Y

DE

PO

T, H

O O

KS

, T

EX

A S

FY

D L A

G

EN

ER

A L

P

UR

PO

SE

W

AR

EH

O

U S E

FE

BR

U

AR

Y

W

G

-1 9-

B-

Fort Worth District

S.

W

EI

SS

EN

ST

EI

N

J.

M

ET

O

YE

R

JE

N

N

IF

ER

A

. D

EW

IT

T, R .A

A-550

C E

IL

IN

G

D E T

AI

LS

S.

W

EI

SS

EN

ST

EI

N

C H

IE

F

AR

C

H

IT

EC

TU

R E

SE

C

TI

O

N

1/8" = 1'-0"

CEILING BRACE 1C1 1/8" = 1'-0"

CEILING BRACE 2C2 1/8" = 1'-0"

CEILING CONSTRUCTIONC4

1/8" = 1'-0"

CEILING SUSPENSIONB1 1/8" = 1'-0"

CEILING AT GRILLEB3 1/8" = 1'-0"

CEILING AT LIGHTING FIXTUREB5

1 1/2" = 1'-0"

CEILING ACCESS PANELA1

SCALE : N.T.S. (NOT TO SCALE) SCALE : N.T.S. (NOT TO SCALE) SCALE : N.T.S. (NOT TO SCALE)

SCALE : N.T.S. (NOT TO SCALE)SCALE : N.T.S. (NOT TO SCALE)SCALE : N.T.S. (NOT TO SCALE)

SCALE : N.T.S. (NOT TO SCALE)

1'-0"

'-8

" A .F

.F

8111'- 6"

SIGNAGE TYPE 2

4'-6"

3" 1'

-0

3"

1' -6

4'-6"

3" 4'-0" 3"

12" HIGH PERMANENT TEXT

HELVETICA NEUE - 85 HEAVY.

CENTERED ON SIGN

SIGN COLOR: DARK BRONZE

TEXT COLOR: WHITE

4'- 8"

A .F

.F

1'- 6"

1'-6"

4 7/8"

SIGNAGE TYPE 1

KNOX BOX

AND POWER

SHUT-OFF

Defense Logistics Agency

General Purpose Warehouse

1/

8"

1/ 8"

1' -6

1'-6"

Defense Logistics

General Purpose Warehouse

Agency

3"

1/ 4"

1/

4"

1/ 4"

3/ 4"1 1/

4" 3/

4"1 1/

4" 3/

4"1 1/

4"

7/ 8"

1/

8"

HELVETICA

NEUE

85 HEAVY

HELVETICA

NEUE

75 BOLD

HELVETICA

NEUE

65 MEDIUM

1 1/8" 1 1/8"

7/ 8"

FLOOR MAT LENGTH, SEE PLANS

FLOOR MAT WIDTH, SEE PLANS

FLOOR FINISH AS SCHEDULED

FLOOR FINISH AS SCHEDULED

EXTRUDED VINYL FILLER, PER MFR.

EXTRUDED VINYL HINGH, PER MFR.

ABRASIVE INSERT

METAL TREAD

EXTRUDED METAL FRAME, PER MFR.

7/ 8"

EXTRUDED METAL FRAME, PER MFR.

FLOOR FINISH AS SCHEDULED

5'- 0"

M

AX

T O

AF

F

2A:10B:C MULTIPURPOSE

DRY CHEMICAL FIRE EXT.

(GFGI-NIC)

ROLLED EDGE SEMI-

RECESSED FIRE EXTINGUISHER

CABINET AS SPECIFIED

BREAK GLASS

HINGED DOOR

BLOCKING AS REQ'D

SEMI-RECESSED FIRE EXTINGUISHER

CABINET SECTION

AT METAL STUD WALL

TYPICAL SEMI-RECESSED FIRE

EXTINGUISHER CABINET

FRONT ELEVATION

NOTES:

1. CABINETS SHALL BE SIZED TO ACCOMMODATE GFGI FIRE

EXTINGUISHERS, COORDINATE WITH CONTRACTING OFFICER.

2. CABINET SHALL BE LOCKABLE.

3. AT ALL FEC LOCATIONS, BRACKET SHALL BE WALL MOUNTED

AT 5'-0" AFF. FIRE EXTINGUISHER TO BE 2A:10B:C (GFGI, NIC)

METAL STUDS

WITH GYP BD

BLOCKING AS REQ'D

4" MAX PROTRUSION PER ABA 307.24" MAX PROTRUSION PER ABA 307.2

5'- 0"

M

AX

T O

AF

F

SEMI-RECESSED FIRE EXTINGUISHER

CABINET SECTION

AT METAL CMU WALL

8" CMU WALL (NOMINAL)

4" CMU (NOMINAL)

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra wn b y:

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e:

C on tra ct

N o.

So lic ita tio n N o.

U .S

. A R

M Y

EN

G

IN

EE

R D

IS

TR

R

PS

O

F

EN

G

IN

EE

R

S

FO

R T

W O

R

TH

, T

EX

AS

R ev ie we d by

US Army Corps of Engineers ®

D

C

B

A

PL

O

T

SC

AL

E:

PL

O

T D

AT

E:

R ev

Sy m bo l

D es cr ip tio n

Tr ac ki ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H As in di ca te d

R E D

RI

VE

R A R

M Y

DE

PO

T, H

O O

KS

, T

EX

A S

FY

D L A

G

EN

ER

A L

P

UR

PO

SE

W

AR

EH

O

U S E

FE

BR

U

AR

Y

W

G

-1 9-

B-

Fort Worth District

S.

W

EI

SS

EN

ST

EI

N

J.

M

ET

O

YE

R

JE

N

N

IF

ER

A

. D

EW

IT

T, R .A

A-570

M

IS

C .

D

ET

A I

LS

I

S.

W

EI

SS

EN

ST

EI

N

/0

1/

C H

IE

F

AR

C

H

IT

EC

TU

R E

SE

C

TI

O

N

1/2" = 1'-0"

SIGN TYPE 2 PLACEMENTC4 3" = 1'-0"

EXTERIOR SIGNAGE TYPE 2C1 66 04 2 1/2" = 1'-0"

SIGN TYPE 1 PLACEMENTC5

3" = 1'-0"

EXTERIOR SIGNAGE TYPE 1A4 66 04 2

01 2 42 001 2 42 0

6" = 1'-0"

ENTRY CARPET DETAILA1 33 02 1

NTS

FIRE EXTINGUISHER CABINET (FEC)1B1

SOUND RATED PARTITION

NOTE: PROVIDE FIRE SEALANT AT

ALL PENETRATIONS THROUGH RATED

ASSEMBLY

BASE

PLAN

HEADER

BASE,

AS

SCHED.

BLOCKING

WHERE

REQ'D

5/8" GYP. BD.

BATT

INSULATION

3 5/8" METAL STUDS

@ 16" O.C. MAX.

BATT INSULATION

EXTENDED OVER

CEILING @ LAY-IN

CEILINGS

BASE

PLAN

HEADER

CEILING AS

SCHEDULED

BATT INSULATION

EXTENDED OVER

CEILING @ LAY-IN

CEILINGS

CEILING AS

SCHEDULED

BATT INSULATION

3 5/8" METAL

STUDS @ 16"

O.C. MAX.

5/8" GYP.

BD.(PROVIDE

CEMENT BD.

AT WALLS

TO RECEIVE

TILE)

BLOCKING

WHERE

REQ'D

SOUND RATED PARTITION

NOTE: PROVIDE ACOUSTIC SEALANT AT

ALL PENETRATIONS THROUGH RATED

ASSEMBLY

BASE

PLAN

HEADER

SOUND RATED PARTITION

NOTE: PROVIDE CEMENTITIOUS BACKER BOARD

AT WALLS TO RECEIVE TILE

BASE

PLAN

HEADER

8" REIFORCED

CMU

CEILING AS

SCHEDULED

BATT INSULATION

EXTENDED OVER

CEILING @ LAY-IN

CEILINGS

SMOKE RATED PARTITION

NOTE: PROVIDE FIRE SEALANT AT

ALL PENETRATIONS THROUGH RATED

ASSEMBLY

BASE

PLAN

HEADER

3 5/8" METAL STUDS @

16" O.C. MAX.

BATT

INSULATION

5/8" GYP BD.

8" CMU,

FULLY

GROUTED

BASE AS

SCHED.

CEILING AS

SCHEDULED

BATT INSULATION

EXTENDED OVER

CEILING @ LAY-IN

CEILINGS

SMOKE/SOUND RATED PARTITION

NOTE: PROVIDE FIRE SEALANT AT

FIRE RATED PENETRATIONS

BASE

PLAN

HEADER

2 1/2" METAL STUDS @ 16"

O.C. MAX.

BATT

INSULATION

5/8" GYP

BD.

CEILING AS

SCHEDULED

BATT INSULATION

EXTENDED OVER

CEILING @ LAY-IN

CEILINGS

NON RATED PARTITION

NOTE: PROVIDE CEMENTITIOUS GROUT

AT WALLS TO RECEIVE TILE.

BASE

PLAN

HEADER

8" REINFORCED CMU,

FULLY GROUTED

CEILING AS

SCHEDULED

BATT INSULATION

EXTENDED OVER

CEILING @ LAY-IN

CEILINGS

NON RATED PARTITION

NOTE: PROVIDE CEMENTITIOUS GROUT

AT WALLS TO RECEIVE TILE.

SEALANT

DECK

MIN.

1'-0"

SEE PLANS

BASE,

AS

SCHED.

2 1/2" METAL

STUDS @ 16"

O.C. MAX.

5/8" GYP. BD.

BATT INSULATION

EXTENDED OVER

CEILING @ LAY-IN

CEILINGS

CEILING AS

SCHEDULED

BLOCKIN

G

WHERE

REQ'D

BASE,

AS

SCHED.

FIRESTOP AND

FIRE SEALANT

DECK

MIN.

1'-0"

MI

N.6"

FIRESTOP AND

FIRE SEALANT

DECK

SEALANT

OFFICE

SIDE

1'-0" MIN.

MI

N.6"

MIN.

1'-0"

SEALANT SEALANT FIRE

SEALANT

BASE

AS

SCHED.

FIRE

SEALANT

SOUND

SEALANT SOUND

SEALANT

8" REINFORCED CMU,

FULLY GROUTED

SEALANT SEALANT

BASE AS

SCHED.

BASE

PLAN

HEADER

6" METAL STUD

@ 16" O.C. MAX

BATT INSULATION

FIRE SEALANT

BOTH SIDES, TYP.

SMOKE RATED PARTITION

NOTE: PROVIDE FIRE SEALANT AT

ALL PENETRATIONS THROUGH RATED

ASSEMBLY

BASE

AS

SCHED.

FIRE SEALANT

5/8" GYP. BD.

DECK

BASE AS

SCHED.

(UL 425)

DECKDECK

MIN.

1'-0"

BRACING AS

REQ'D

(STC 55)

1'-0" MIN.

SMOKE/SOUND RATED PARTITION

NOTE: PROVIDE FIRE SEALANT AT

ALL PENETRATIONS THROUGH RATED

ASSEMBLY

BASE

PLAN

HEADER

BASE, AS

SCHED. BLOCKING

WHERE

REQ'D

5/8" SOUND

RATED GYP.

BD.

BATT

INSULATION

3 5/8" METAL STUDS

@ 16" O.C. MAX.

BATT INSULATION

EXTENDED OVER

CEILING @ LAY-IN

CEILINGS

CEILING AS

SCHEDULED

SEALANT

DECK

MIN.

1'-0"

(STC 52) UL 465

7 1/4"

METAL

RESILIENT

CHANNEL @

24" O.C. VERT.

5 3/8"

CORRIDOR SIDE

BREAKROOM SIDE

FIRE SEALANT

BOTH SIDES, TYP.

MIN.

1'-0"

5/8" TYPE X

GYP. BD.

1'-1 7/8" 11 7/8"

MIN.

1'-0"

BASE

NON RATED PARTITION

NOTE: PROVIDE CEMENTITIOUS GROUT

AT WALLS TO RECEIVE TILE.

BASE AS

SCHED.

SEALANT SEALANT

HEADER

CEILING AS

SCHEDULED

PLAN

1 2(STC 44) UL 465

BATT INSULATION

EXTENDED OVER

CEILING @ LAY-IN

CEILINGS

BOND BEAM SEE

STRUCTURAL

MIN.

1'-0"

CONCRETE LID, SEE

STRUCT.

4 7/8" 4 1/4"

7 5/8"

(STC 52)

BASE

NON RATED PARTITION

NOTE: PROVIDE CEMENTITIOUS GROUT

AT WALLS TO RECEIVE TILE.

BASE AS SCHED.

SEALANT SEALANT

HEADER

CEILING AS

SCHEDULED

PLAN

BATT INSULATION

EXTENDED OVER

CEILING @ LAY-IN

CEILINGS

BOND BEAM SEE

STRUCTURAL

METAL DECK, SEE

STRUCT.

7 5/8"

CMU

WALL

CMU WALL

'-8

MIN.

1'-0".

METAL FRAMING AS

REQUIRED FOR

CEILING SUPPORT

2"

UL 465

UL 465

FIRESTOP AND

FIRE SEALANT

DECKUL 465

FIRESTOP AND

FIRE SEALANT

DECK

UL 465

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra wn b y:

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e:

C on tra ct

N o.

So lic ita tio n N o.

U .S

. A R

M Y

EN

G

IN

EE

R D

IS

TR

R

PS

O

F

EN

G

IN

EE

R

S

FO

R T

W O

R

TH

, T

EX

AS

R ev ie we d by

US Army Corps of Engineers ®

D

C

B

A

PL

O

T

SC

AL

E:

PL

O

T D

AT

E:

R ev

Sy m bo l

D es cr ip tio n

Tr ac ki ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H

'-0

R E D

RI

VE

R A R

M Y

DE

PO

T, H

O O

KS

, T

EX

A S

FY

D L A

G

EN

ER

A L

P

UR

PO

SE

W

AR

EH

O

U S E

FE

BR

U

AR

Y

W

G

-1 9-

B-

Fort Worth District

S.

W

EI

SS

EN

ST

EI

N

J.

M

ET

O

YE

R

JE

N

N

IF

ER

A

. D

EW

IT

T, R .A

A-601

P A

RT

I T

IO

N T Y

PE

S

S.

W

EI

SS

EN

ST

EI

N

C H

IE

F

AR

C

H

IT

EC

TU

R E

SE

C

TI

O

N

1" = 1'-0"

WALL PARTITIONSA1 01/2 1 21 0

GENERAL PARTITION TYPE NOTES:

1. ALL GYP. BD. WALLS SHALL BE IMPACT RESISTANT TYPE UP TO 8'-0" AFF.

2. ALL METAL STUD FRAMING SHALL BE MINIMUM 20 GA AND MAXIMUM SPACING SHALL BE 16" O.C. UNLESS NOTED OTHERWISE.

3. PROVIDE DEFLECTION TRACK TO ACCOMODATE 1.5" OF VERTICAL MOVEMENT WHERE PARTITION FRAMING IS ATTACHED TO DECK OR STRUCTURE ABOVE.

4. SEE INTERIORS DRAWINGS FOR INTERIOR FINISH SCHEDULE.

5. WHERE TILE FINISH IS USED PER INTERIOR FINISH SCHEDULE, USE 5/8" CEMENT BACKER BOARD IN LIEU OF GYP. BD.

6. PARTITIONS AT RESTROOMS, JANITOR'S CLOSETS AND SHOWERS THAT DO NOT RECEIVE CERAMIC TILE SHALL USE MOISTURE RESISTANT GYP. BD.

7. SEE REFLECTED CEILING PLANS FOR CEILING HEIGHTS AND CEILING TYPES SCHEDULED.

8. SEAL ALL PENETRATIONS WITH FIRE SEALANT WHERE PARTITION IS FIRE RATED OR SMOKE RATED OR BOTH.

AS SCHEDULED

AS

S

CH

ED

UL

ED

A B C

PAIR

D

E

SLIDING FIRE DOOR

F

4"6"

2'- 0"

6"

6" 6"

6" 8"

SEE SCHED.

SE

E

SC

HE

D.

SE

E

SC

HE

D.

2"

1'- 4"

2"

A

D

B C

SE

E

SC

HE

D.

4"

2" SEE SCHED. 2"2" SEE SCHED. 2"

SE

E

SC

HE

D.

2"

SE

E

SC

HE

D.

4"

2" SEE SCHED. 2"

2" SEE SCHED. 2" 4'-6" 2"

2"

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra wn b y:

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e:

C on tra ct

N o.

So lic ita tio n N o.

U .S

. A R

M Y

EN

G

IN

EE

R D

IS

TR

R

PS

O

F

EN

G

IN

EE

R

S

FO

R T

W O

R

TH

, T

EX

AS

R ev ie we d by

US Army Corps of Engineers ®

D

C

B

A

PL

O

T

SC

AL

E:

PL

O

T D

AT

E:

R ev

Sy m bo l

D es cr ip tio n

Tr ac ki ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H

/4

'-0

R E D

RI

VE

R A R

M Y

DE

PO

T, H

O O

KS

, T

EX

A S

FY

D L A

G

EN

ER

A L

P

UR

PO

SE

W

AR

EH

O

U S E

FE

BR

U

AR

Y

W

G

-1 9-

B-

Fort Worth District

S.

W

EI

SS

EN

ST

EI

N

J.

M

ET

O

YE

R

JE

N

N

IF

ER

A

. D

EW

IT

T, R .A

A-602

D O O

R

SC

HE

DU

LE

S.

W

EI

SS

EN

ST

EI

N

C H

IE

F

AR

C

H

IT

EC

TU

R E

SE

C

TI

O

N

USACE DOOR SCHEDULE

DOOR

NUMBER TYPE

DOOR

FIRE

RATING

FRAME

HARDWARE COMMENTS

SIZE

MATERIAL FINISH UNDERCUT TYPE MATERIAL FINISH

DETAILS

WIDTH HEIGHT THICKNESS HEAD JAMB SILL

USACE DOOR SCHEDULE

DOOR

NUMBER TYPE

DOOR

FIRE

RATING

FRAME

HARDWARE COMMENTS

SIZE

MATERIAL FINISH UNDERCUT TYPE MATERIAL FINISH

DETAILS

WIDTH HEIGHT THICKNESS HEAD JAMB SILL

100A A 3'-0" 7'-0" 1 3/4" HM PT 0" A HM PT D3/A-530 C3/A-530 A3/A-530 HW-1

100B F 14'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE 100C F 14'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE 100D F 14'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE

100E A 3'-0" 7'-0" 1 3/4" HM PT 0" A HM PT D3/A-530 C3/A-530 A3/A-530 HW-1

100F E 4'-0" 7'-0" HM PT 0" 3HR SLIDING MTL SEE FINISH

SCHEDULE

D5/A-532 PER MFR. B5/A-532 - FIRE RATED W/ NARROW GLAZING DOOR ON

CENTER WITH WALL

100G F 14'-0" 14'-0" 1" STL PC 0" 3HR OVERHEAD STL PT D3/A-531 C3/A-531 B3/A-531 - FIRE RATED, 1-HP ELEC. MOTOR, 208V/3-PHASE.

100H F 14'-0" 14'-0" 1" STL PC 0" 3HR OVERHEAD STL PT D3/A-531 C3/A-531 B3/A-531 - FIRE RATED, 1-HP ELEC. MOTOR, 208V/3-PHASE.

100I E 4'-0" 7'-0" HM PT 0" 3HR SLIDING MTL SEE FINISH

SCHEDULE

D5/A-532 PER MFR. B5/A-532 - FIRE RATED W/ NARROW GLAZING DOOR ON

CENTER WITH WALL

100J A 3'-0" 7'-0" 1 3/4" HM PT 0" A HM PT D3/A-530 C3/A-530 A3/A-530 HW-1

100K F 9'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE 100L F 9'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE 100M F 9'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE 100N F 14'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE

100P A 3'-0" 7'-0" 1 3/4" HM PT 0" A HM PT D3/A-530 C3/A-530 A3/A-530 HW-1

101A A 3'-0" 7'-0" 1 3/4" HM PT 0" A HM PT D3/A-530 C3/A-530 A3/A-530 HW-1

101B F 14'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE 101C F 14'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE

101E A 3'-0" 7'-0" 1 3/4" HM PT 0" 3HR B HM PT D1/A-531 C1/A-531 A1/A-531 HW-4

101F F 14'-0" 14'-0" 1" STL PC 0" 3HR OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - FIRE RATED, 1-HP ELEC. MOTOR, 208V/3-PHASE.

101G C 6'-0" 7'-0" 2" HM PT 0" 3HR C HM PT D1/A-531 C1/A-531 A1/A-531 HW-3

101H A 3'-0" 7'-0" 1 3/4" HM PT 0" 3HR B HM PT D1/A-531 C1/A-531 A1/A-531 HW-2A

101I A 3'-0" 7'-0" 1 3/4" HM PT 0" 3HR B HM PT D1/A-531 C1/A-531 A1/A-531 HW-2B STC 33

101K E 4'-0" 7'-0" STL PT 0" 3HR SLIDING STL SEE FINISH

SCHEDULE

D5/A-532 PER MFR. B5/A-532 - FIRE RATED W/ NARROW GLAZING DOOR ON

CENTER WITH WALL

101L F 14'-0" 14'-0" 1" STL PC 0" 3HR OVERHEAD STL PT D3/A-531 C3/A-531 B3/A-531 - FIRE RATED, 1-HP ELEC. MOTOR, 208V/3-PHASE.

101M F 14'-0" 14'-0" 1" STL PC 0" 3HR OVERHEAD STL PT D3/A-531 C3/A-531 B3/A-531 - FIRE RATED, 1-HP ELEC. MOTOR, 208V/3-PHASE.

101N E 4'-0" 7'-0" STL PT 0" 3HR SLIDING STL SEE FINISH

SCHEDULE

D5/A-532 PER MFR. B5/A-532 - FIRE RATED W/ NARROW GLAZING DOOR ON

CENTER WITH WALL

101P A 3'-0" 7'-0" 1 3/4" HM PT 0" A HM PT D3/A-530 C3/A-530 A3/A-530 HW-1

101R F 9'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE 101S F 9'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE 101T F 9'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE

101U A 3'-0" 7'-0" 1 3/4" HM PT 0" 3HR A HM PT D5/A-532 C5/A-530 B5/A-532 HW-4

101V F 14'-0" 14'-0" 1" STL PC 0" 3HR OVERHEAD STL PT D3/A-531 C3/A-531 B3/A-531 - FIRE RATED, 1-HP ELEC. MOTOR, 208V/3-PHASE.

101W F 14'-0" 14'-0" 1" STL PC 0" 3HR OVERHEAD STL PT D3/A-531 C3/A-531 B3/A-531 - FIRE RATED, 1-HP ELEC. MOTOR, 208V/3-PHASE.

101X A 3'-0" 7'-0" 1 3/4" HM PT 0" 3HR A HM PT D5/A-532 C3/A-530 B5/A-532 HW-4

101Y A 3'-0" 7'-0" 1 3/4" HM PT 0" A HM PT D3/A-530 C3/A-530 A3/A-530 HW-1

102A A 3'-0" 7'-0" 1 3/4" HM PT 0" A HM PT D3/A-530 C3/A-530 A3/A-530 HW-1

102B F 9'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE 102C F 9'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE 102D F 9'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE

102E A 3'-0" 7'-0" 1 3/4" HM PT 0" A HM PT D3/A-530 C3/A-530 A3/A-530 HW-1

102F E 4'-0" 7'-0" STL PT 0" 3HR SLIDING STL SEE FINISH

SCHEDULE

D5/A-532 PER MFR. B5/A-532 - FIRE RATED W/ NARROW GLAZING DOOR ON

CENTER WITH WALL

102G F 14'-0" 14'-0" 1" STL PC 0" 3HR OVERHEAD STL PT D3/A-531 C3/A-531 B3/A-531 - FIRE RATED, 1-HP ELEC. MOTOR, 208V/3-PHASE.

102H F 14'-0" 14'-0" 1" STL PC 0" 3HR OVERHEAD STL PT D3/A-531 C3/A-531 B3/A-531 - FIRE RATED, 1-HP ELEC. MOTOR, 208V/3-PHASE.

102I E 4'-0" 7'-0" STL PT 0" 3HR SLIDING STL SEE FINISH

SCHEDULE

D5/A-532 PER MFR. B5/A-532 - FIRE RATED W/ NARROW GLAZING DOOR ON

CENTER WITH WALL

102J A 3'-0" 7'-0" 1 3/4" HM PT 0" A HM PT D3/A-530 C3/A-530 A3/A-530 HW-1

102K F 9'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE 102L F 9'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE 102M F 9'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE

102N A 3'-0" 7'-0" 1 3/4" HM PT 0" A HM PT D3/A-530 C3/A-530 A3/A-530 HW-1

102P A 3'-0" 7'-0" 1 3/4" HM PT 0" 3HR A HM PT D5/A-532 C3/A-530 B5/A-532 HW-4

102Q F 14'-0" 14'-0" 1" STL PC 0" 3HR OVERHEAD STL PT D3/A-531 C3/A-531 B3/A-531 - FIRE RATED, 1-HP ELEC. MOTOR, 208V/3-PHASE.

102R F 14'-0" 14'-0" 1" STL PC 0" 3HR OVERHEAD STL PT D3/A-531 C3/A-531 B3/A-531 - FIRE RATED, 1-HP ELEC. MOTOR, 208V/3-PHASE.

102S A 3'-0" 7'-0" 1 3/4" HM PT 0" 3HR A HM PT D5/A-532 C3/A-530 B5/A-532 HW-4

103A A 3'-0" 7'-0" 1 3/4" HM PT 0" A HM PT D3/A-530 C3/A-530 A3/A-530 HW-1

103B F 9'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE 103C F 9'-0" 14'-0" 1" STL PC 0" OVERHEAD STL - C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE 103D F 9'-0" 14'-0" 1" STL PC 0" OVERHEAD STL - C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE 103E F 14'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE

103F A 3'-0" 7'-0" 1 3/4" HM PT 0" A HM PT D3/A-530 C3/A-530 A3/A-530 HW-1

103G A 3'-0" 7'-0" 1 3/4" HM PT 0" A HM PT D3/A-530 C3/A-530 A3/A-530 HW-1

103H F 14'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE 103I F 9'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE 103J F 9'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE 103K F 9'-0" 14'-0" 1" STL PC 0" OVERHEAD STL PT C5/A-531 B5/A-531 A4/531 - 3-HP ELEC. MOTOR., 208V/3-PHASE

103L A 3'-0" 7'-0" 1 3/4" HM PT 0" A HM PT D3/A-530 C3/A-530 A3/A-530 HW-1

103M A 3'-0" 7'-0" 1 3/4" HM PT 0" 3HR A HM PT D5/A-532 C3/A-530 B5/A-532 HW-4

103N F 14'-0" 14'-0" 1" STL PC 0" 3HR OVERHEAD STL PT D3/A-531 C3/A-531 B3/A-531 - FIRE RATED, 1-HP ELEC. MOTOR, 208V/3-PHASE.

103P F 14'-0" 14'-0" 1" STL PC 0" 3HR OVERHEAD STL PT D3/A-531 C3/A-531 B3/A-531 - FIRE RATED, 1-HP ELEC. MOTOR, 208V/3-PHASE.

103Q A 3'-0" 7'-0" 1 3/4" HM PT 0" 3HR A HM PT D5/A-532 C3/A-530 B5/A-532 HW-4

104 A 3'-0" 7'-0" 1 3/4" HM PT A HM PT D3/A-530 C3/A-530 A3/A-530 HW-1

105 A 3'-0" 7'-0" 1 3/4" HM PT 0" A HM PT D3/A-530 C3/A-530 A3/A-530 HW-2A

106 A 3'-0" 7'-0" 1 3/4" HM PT 0" A HM PT D3/A-530 C3/A-530 A3/A-530 HW-1

107 A 3'-0" 7'-0" 1 3/4" HM PT 0" A HM PT D3/A-530 C3/A-530 A3/A-530 HW-2A

108 C 3'-0" 7'-0" 1 3/4" HM PT 0" C HM PT D2/A-530 C2/A-530 A2/A-530 HW-6A

109 C 3'-0" 7'-0" 1 3/4" HM PT 0" C HM PT D2/A-530 C2/A-530 A2/A-530 HW-6

110 B 3'-0" 7'-0" 1 3/4" WD STAIN A HM PT D4/A-530 C4/A-530 A4/A-530 HW-7 STC 33

111 B 3'-0" 7'-0" 1 3/4" WD STAIN A HM PT D4/A-530 C4/A-530 A4/A-530 HW-7 STC 33

115A D 3'-0" 7'-0" 1 3/4" ALUM. CLR. ANOD. 0" D ALUM. CLR.

ANOD.

D1/ A-530 C1/ A-530 A1/ A-530 HW-8A

115B D 3'-0" 7'-0" 1 3/4" ALUM. CLR. ANOD. D ALUM. CLR.

ANOD.

D1/ A-530 C1/ A-530 A1/ A-530 HW-8

116 B 3'-0" 7'-0" 1 3/4" WD STAIN 0" 1HR A HM PT D4/A-530 C4/A-530 A4/A-530 HW-9 STC 33 118 A 3'-0" 7'-0" 1 3/4" WD STAIN 0" A HM PT D4/A-530 C4/A-530 A4/A-530 HW-7 STC 33 119 A 3'-0" 7'-0" 1 3/4" WD STAIN 0" B HM PT A1/A-531 A3/A-531 A4/A-530 HW-10 STC 33

119A A 3'-0" 7'-0" 1 3/4" HM PT 0" B HM PT D3/A-530 C3/A-530 A3/A-530 HW-11 STORM SHELTER DOOR

120 A 3'-0" 7'-0" 1 3/4" WD STAIN 0" B HM PT A1/A-531 A3/A-531 A4/A-530 HW-5

121 A 3'-0" 7'-0" 1 3/4" WD STAIN 0" B HM PT A1/A-531 A3/A-531 A4/A-530 HW-10 STC 33

121A A 3'-0" 7'-0" 1 3/4" HM PT 0" B HM PT D3/A-530 C3/A-530 A3/A-530 HW-11 STORM SHELTER DOOR

122 A 3'-0" 7'-0" 1 3/4" HM PT B HM PT D3/A-530 C3/A-530 A3/A-530 HW-1

122A A 3'-0" 7'-0" 1 3/4" HM PT 0" B HM PT D3/A-530 C3/A-530 A3/A-530 HW-2A

123 A 3'-0" 7'-0" 1 3/4" HM PT 0" A HM PT D3/A-530 C3/A-530 A3/A-530 HW-2A

124 A 3'-0" 7'-0" 1 3/4" HM PT 0" A HM PT D3/A-530 C3/A-530 A3/A-530 HW-1

127 A 3'-0" 7'-0" 1 3/4" HM PT 0" B HM PT D3/A-530 C3/A-530 A3/A-530 HW-2A

128 A 3'-0" 7'-0" 1 3/4" HM PT 0" B HM PT D3/A-530 C3/A-530 A3/A-530 HW-2A

131 A 3'-0" 7'-0" 1 3/4" HM PT 0" B HM PT D3/A-530 C3/A-530 A3/A-530 HW-2A

133 A 3'-0" 7'-0" 1 3/4" HM PT 0" B HM PT D3/A-530 C3/A-530 A3/A-530 HW-2A

135 A 3'-0" 7'-0" 1 3/4" HM PT B HM PT D3/A-530 C3/A-530 A3/A-530 HW-2A

135A A 3'-0" 7'-0" 1 3/4" HM PT B HM PT D3/A-530 C3/A-530 A3/A-530 HW-2A

138 A 3'-0" 7'-0" 1 3/4" HM PT 0" B HM PT D3/A-530 C3/A-530 A3/A-530 HW-2A

139 A 3'-0" 7'-0" 1 3/4" HM PT 0" B HM PT D3/A-530 C3/A-530 A3/A-530 HW-2A

140 A 3'-0" 7'-0" 1 3/4" HM PT B HM PT D3/A-530 C3/A-530 A3/A-530 HW-2A

140A A 3'-0" 7'-0" 1 3/4" HM PT B HM PT D3/A-530 C3/A-530 A3/A-530 HW-2A

1/4" = 1'-0"

DOOR TYPESC3 1/4" = 1'-0"

FRAME TYPESC502 4 8134 02 4 8134

DOOR SCHEDULE NOTES:

1. CONTRACTOR SHALL COORINATE DOOR FRAME WIDTHS WITH SCHEDULED WALL TYPES, CONTRACTOR SHALL COORDINATE MANUFACTURER ROUGH OPENING

REQUIREMENT WITH SCHEDULED WALL TYPES.

2. ALL RATED DOORS SHALL HAVE MATCHING RATED FRAMES.

3. COORDINATE OVERHEAD DOOR MOTOR DEVICES REQUIREMENTS WITH ELECTRICAL DRAWINGS.

4. FOR INTERIOR FRAME FINISH COLORS ( SCHEDULED AS "PT") SEE INTERIOR FINISH SCHEDULE.

5. FOR INTERIOR DOOR FINISH COLORS (SCHEDULED AS "PT") SEE INTERIOR FINISH SCHEDULE. FOR "PT" LABELS NOT FOUND ON INTERIORS FINISH SCHEDULE, PT

REFERS TO "PAINT."

6. FOR STAIN COLORS ON WOOD DOORS SEE INTERIOR FINISH SCHEDULE.

IN

SI

DE

OU

TS

ID

E

1"

1 2 3 4

LOW E COAT ON

2ND SURFACE

CLEAR/VISION FROSTED

IN

SI

DE

1 2

OU

TS

ID

E

3 4

SIMULATED FROSTING PVB

INTERLAYER BETWEEN

SURFACE 2 AND 3

SPANDREL

(ANNEALED LAMINATED, SIMULATED

FROSTING PVB INTERLAYER)

IN

SI

DE

1 2

OU

TS

ID

E

3 4

SIMULATED FROSTING PVB

INTERLAYER BETWEEN

SURFACE 2 AND 3

SEE SCHEDULE

SE

E

SC

HE

DU

LE

SI

LL

H

EI

GH

T

FFE

AA

2" 2"

2" 2"

SI

LL

H

EI

GH

T

2"

SE

E

SC

HE

D.

2"

2" SEE SCHED. 2"

FFE

L----

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra wn b y:

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e:

C on tra ct

N o.

So lic ita tio n N o.

U .S

. A R

M Y

EN

G

IN

EE

R D

IS

TR

R

PS

O

F

EN

G

IN

EE

R

S

FO

R T

W O

R

TH

, T

EX

AS

R ev ie we d by

US Army Corps of Engineers ®

D

C

B

A

PL

O

T

SC

AL

E:

PL

O

T D

AT

E:

R ev

Sy m bo l

D es cr ip tio n

Tr ac ki ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H As in di ca te d

R E D

RI

VE

R A R

M Y

DE

PO

T, H

O O

KS

, T

EX

A S

FY

D L A

G

EN

ER

A L

P

UR

PO

SE

W

AR

EH

O

U S E

FE

BR

U

AR

Y

W

G

-1 9-

B-

Fort Worth District

S.

W

EI

SS

EN

ST

EI

N

J.

M

ET

O

YE

R

JE

N

N

IF

ER

A

. D

EW

IT

T, R .A

A-603

L O

UV

E R /W

IN

DO

W S

CH

ED

UL

E

S.

W

EI

SS

EN

ST

EI

N

C H

IE

F

AR

C

H

IT

EC

TU

R E

SE

C

TI

O

N

6" = 1'-0"

GLAZING SCHEDULE SURFACESD4

USACE WINDOW AND LOUVER SCHEDULE

WINDOW/LOUVER

NO.

ROUGH OPENING

TYPE

FRAME GLAZING DETAILS

SILL HEIGHT COMMENTSWIDTH HEIGHT FINISH MATERIAL TYPE THICKNESS HEAD JAMB SILL

AA 3'-4" 5'-10 1/4" WINDOW FIXED ANOD. ALUM INSULATED 1" D3/ A-540 C3/ A-540 A3/ A-540 2'-9 3/4" SEE SCHEDULES FOR FINISHES FOR ANODIZED

COLOR

L-1 4'-7 1/2" 2'-7 1/2" FIXED LOUVER PT MTL N/A N/A D4/ A-540 C4/A-540 A4/ A-540 10'-0" L-2 2'-7 1/2" 1'-7 1/2" FIXED LOUVER PT MTL N/A N/A D4/ A-540 C4/A-540 A4/ A-540 11'-0" L-3 5'-6" 5'-0" FIXED LOUVER PT MTL N/A N/A D5/ A-540 C5/A-540 A5/ A-540 19'-5 1/4"

L-5 5'-6" 5'-0" FIXED LOUVER PT MTL N/A N/A D5/ A-540 C5/A-540 A5/ A-540 20'-4"

L-6 1'-6" 1'-0" FIXED LOUVER PT MTL N/A N/A D4/ A-540 C4/A-540 A4/ A-540 11'-7"

L-7 1'-6" 1'-0" FIXED LOUVER PT MTL N/A N/A D4/ A-540 C4/A-540 A4/ A-540 10'-3"

L-8 2'-0" 1'-6" FIXED LOUVER PT MTL N/A N/A D5/ A-540 C5/A-540 A5/ A-540 10'-0"

1/2" = 1'-0"

WINDOW TYPESD3 01 2 42 0

WINDOW AND LOUVER SCHEDULE GENERAL NOTES:

1. CONTRACTOR SHALL COORDINATE SCHEDULED OPENING AND FRAME WIDTHS WITH MANUFACTURER REQUIRED ROUGH OPENINGS IN WALLS WHICH LOUVERS, WINDOWS, OR BOTH ARE PLACED.

2. SEE MECHANICAL DRAWINGS AND SCHEDULES FOR MORE LOUVER REQUIREMENTS.

2. WINDOW FRAME SITELINES SHOWN ARE NOMINAL.

4. LOUVER FRAME SITELINES SHOWN ARE NOMINAL.

01 2 42 0

1/2" = 1'-0"

LOUVER TYPESC3 01 2 42 0

DNDN

DN

I-102

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra wn b y:

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e:

C on tra ct

N o.

So lic ita tio n N o.

U .S

. A R

M Y

EN

G

IN

EE

R D

IS

TR

R

PS

O

F

EN

G

IN

EE

R

S

FO

R T

W O

R

TH

, T

EX

AS

R ev ie we d by

US Army Corps of Engineers ®

D

C

B

A

PL

O

T

SC

AL

E:

PL

O

T D

AT

E:

R ev

Sy m bo l

D es cr ip tio n

Tr ac ki ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H

0' -0

R E D

RI

VE

R A R

M Y

DE

PO

T, H

O O

KS

, T

EX

A S

FY

D L A

G

EN

ER

A L

P

UR

PO

SE

W

AR

EH

O

U S E

FE

BR

U

AR

Y

Fort Worth District

H . K

IM

BR

O W

, R .I.

D

H . K

IM

BR

O W

, R .I.

D

JE

N

N

IF

ER

A

. D

EW

IT

T, R .A

I-101

O

VE

RA

LL

F

UR

N I

TU

R E F

LO

O

R P L

AN

B.

TI

N

D

EL

L, R

.A

/2

7/

C H

IE

F, A R

C H

IT

EC

TU

R

E

SE

C

TI

O N

1" = 40'-0"I-101

1 OVERALL FURNITURE FLOOR PLAN KEYPLAN

A

B

C

D

E

F

G

H

I

PLAN

NORTH

600204060

W

G

-1 9-

B-

BATTERY CHARGER

ROOM

MECHANICAL ROOM

TEL. ROOM

OFFICE

OFFICE

OFFICE

D1

D1

C1

C1

D1

D1 D1

C1

C1 C1

C2 C2

C2

T1T1

T1

C2 T1

VESTIBULE

STORAGE ROOM

LOCKER ROOM

121A

MEN

JAN

WOMEN

LOCKER ROOM

119A

BREAKROOM

RECYCLE STORAGE

ELEC. ROOM

A1

CB

M1 M1

VM VM

P1

P1

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra wn b y:

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e:

C on tra ct

N o.

So lic ita tio n N o.

U .S

. A R

M Y

EN

G

IN

EE

R D

IS

TR

R

PS

O

F

EN

G

IN

EE

R

S

FO

R T

W O

R

TH

, T

EX

AS

R ev ie we d by

US Army Corps of Engineers ®

D

C

B

A

PL

O

T

SC

AL

E:

PL

O

T D

AT

E:

R ev

Sy m bo l

D es cr ip tio n

Tr ac ki ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H

/8

'-0

R E D

RI

VE

R A R

M Y

DE

PO

T, H

O O

KS

, T

EX

A S

FY

D L A

G

EN

ER

A L

P

UR

PO

SE

W

AR

EH

O

U S E

FE

BR

U

AR

Y

Fort Worth District

H . K

IM

BR

O W

, R .I.

D

H . K

IM

BR

O W

, R .I.

D

JE

N

N

IF

ER

A

. D

EW

IT

T, R .A

I-102

EN

LA

RG

ED

F

UR

NI

TU

R E F

LO

O

R P L

AN

A R

EA

I

B.

TI

N D

EL

L, R .A

/2

7/

C H

IE

F, A R

C H

IT

EC

TU

R

E

SE

C

TI

O N

KEYPLAN

A

B

C

D

E

F

G

H

I

PLAN

NORTH

0 84 16268

SCALE: 1/8"=1'-0"

1/8" = 1'-0"I-102

1 ENLARGED FURNITURE PLAN AREA I

FURNITURE LEGEND

SYMBOL DESCRIPTION

A1 RECYCLING BIN

C1

C2 BREAKROOM CHAIR

TASK CHAIR

T1

COFFEE BREWERCB

BREAKROOM TABLE

NOTES

1. ALL FURNISHINGS AND EQUIPMENT ON THIS PLAN ARE PROVIDED FOR

COORDINATION AND SPACE PLANNING PURPOSES ONLY AND SHALL BE

CONSIDERED NOT IN CONTRACT (N.I.C.) FOR THE CONSTRUCTION CONTRACT.

2. VISUAL COMMUNICATION ITEMS REQUIRE ADDITIONAL SUPPORT BLOCKING,

PROVIDE SUFFICIENT SUPPORT FOR INSTALLED ITEM.

3. ALL WORKSTATIONS SHALL HAVE INDIVIDUALLY CONTROLLED TASK LIGHTING.

4. RECYCLABLE MATERIAL RECEPTACLES AND STORAGE AREA SHALL INCLUDE AT

A MINIMUM SEPARATE BINS FOR "PAPER", "CARDBOARD", "GLASS", "PLASTICS",

AND "METALS". STATION SHALL ALSO INCLUDE COLLECTION BINS FOR BATTERIES

AND ELECTRONIC WASTE AS DEFINED BY THE LEED VERSION FOR THIS PROJECT.

5. ALL FURNITURE FINISHES SHALL MEET THE FOLLOWING THRESHOLDS FOR

AREA-WEIGHTED AVERAGE SURFACE REFLECTANCE: 45% FOR WORK SURFACES,

AND 50% FOR MOVABLE PARTITIONS.

M1 MICROWAVE

VM VENDING MACHINE

P1 PRINTER

D1 DESK

W

G

-1 9-

B-

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra wn b y:

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e:

C on tra ct

N o.

So lic ita tio n N o.

U .S

. A R

M Y

EN

G

IN

EE

R D

IS

TR

R

PS

O

F

EN

G

IN

EE

R

S

FO

R T

W O

R

TH

, T

EX

AS

R ev ie we d by

US Army Corps of Engineers ®

D

C

B

A

PL

O

T

SC

AL

E:

PL

O

T D

AT

E:

R ev

Sy m bo l

D es cr ip tio n

Tr ac ki ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H

R E D

RI

VE

R A R

M Y

DE

PO

T, H

O O

KS

, T

EX

A S

FY

D L A

G

EN

ER

A L

P

UR

PO

SE

W

AR

EH

O

U S E

FE

BR

U

AR

Y

Fort Worth District

H . K

IM

BR

O W

, R .I.

D

H . K

IM

BR

O W

, R .I.

D

JE

N

N

IF

ER

A

. D

EW

IT

T, R .A

I-601

I N

TE

R I O

R F I

NI

SH

S

CH

E D

UL

E B.

T

IN

D

EL

L, R

.A

/2

7/

C H

IE

F, A R

C H

IT

EC

TU

R

E

SE

C

TI

O N

INTERIOR FINISH SCHEDULE

ESABROOLFEMAN MOOR.ON

WALL FINISH

NORTH EAST SOUTH WEST

1-TP1-TP1-TP1-TP-1-PEESUOHERAW001

1-TP1-TP1-TP1-TP-1-PEESUOHERAW101

1-TP1-TP1-TP1-TP-1-PEESUOHERAW201

1-TP1-TP1-TP1-TP-1-PEESUOHERAW301

1-TP1-TP1-TP1-TP-1-PEMOOR .CELE401

1-TP1-TP1-TP1-TP-1-PESEITILITU501

1-TP1-TP1-TP1-TP-1-PESEITILITU601

1-TP1-TP1-TP1-TP-1-PEMOOR .LET701

1-TP1-TP1-TP1-TP-1-PEMOOR REGRAHC YRETTAB801

1-TP1-TP1-TP1-TP-1-PEMOOR LACINAHCEM901

2-TP2-TP2-TP2-TP1-BR1-TPCECIFFO011

2-TP2-TP2-TP2-TP1-BR1-TPCECIFFO111

1-TP1-TP1-TP1-TP-1-PEMOOR .CELE211

1-TP1-TP1-TP1-TP-1-PEMOOR .LET311

2-TP2-TP2-TP2-TP1-BR1-TPCECIFFO411

P1-BRMRELUBITSEV511 T-2 PT-2 PT-2 PT-2

2-TP2-TP2-TP2-TP1-BR1-FRMOORKAERB611

1-FREGAROTS ELCYCER711 RB-1 PT-2 PT-2 PT-2 PT-2

2-TP2-TP2-TP2-TP1-BR1-FRMOOR EGAROTS811

1-TC1-TC1-TC1-TC1-BTP1-ROPNEMOW911

1-TC1-TC1-TC1-TC1-BTP1-ROPMOOR REKCOLA911

F1-TP/PRF1-BR1-CSNAJ021 RP/PT-1 FRP/PT-1 FRP/PT-1

1-TC1-TC1-TC1-TC1-BTP1-ROPNEM121

1-TC1-TC1-TC1-TC1-BTP1-ROPMOOR REKCOLA121

1-TP1-TP1-TP1-TP-1-PEMOOR .LET221

1-TP1-TP1-TP1-TP-1-PEMOOR .CELEA221

1-TP1-TP1-TP1-TP-1-PESEITILITU321

1-TP1-TP1-TP1-TP-1-PESEITILITU421

1-TP1-TP1-TP1-TP-1-PEMOOR MOCELET721

1-TP1-TP1-TP1-TP-1-PEMOOR .CELE821

1-TP1-TP1-TP1-TP-1-PEMOOR MOCELET131

1-TP1-TP1-TP1-TP-1-PEMOOR .CELE331

1-TP1-TP1-TP1-TP-1-PEMOOR .CELE531

1-TP1-TP1-TP1-TP-1-PEMOOR MOCELETA531

1-TP1-TP1-TP1-TP-1-PEMOOR MOCELET831

1-TP1-TP1-TP1-TP-1-PEMOOR .CELE931

1-TP1-TP1-TP1-TP-1-PEMOOR .CELE041

1-TP1-TP1-TP1-TP-1-PEMOOR MOCELETA041

INTERIOR COLOR FINISH LEGEND

ROLOCREBMUN TCUDORPRERUTCAFUNAMLAIRETAMLOBMYS NOTES

HGIH DERUSSIF ENIFETIHW6571GNORTSMRAELIT GNILIEC CITSUOCA1-TCA NRC; ANGLED TEGULAR 15/16 IN w/PRELUDE XL 15/16" SUSPENSION SYSTEM AUG RENROC LYNIV ELBIXELFYROVI1632MOC.DRAUGLLAWDRAUG RENROC1-GC RD; 2 1/2" x 2 1/2" x 48"

ESUOHNETTIRETIHW CITCRA ETTAM0970ELITLADELIT LLAW NIALECROP1-TC SQUARE, 3" X 6" BRICK-JOINT INSTALLATION ID NON ;mc 05 ;AIRBMACWODAEM555201ECAFRETNIGNIROOLF TEPRAC1-TPC RECTIONAL INSTALLATION

GNIROOLF REGNAH/ECAPSOREAPROC SROOLF PEGNIROOLF YXOPE1-PE CHEMICAL / SLIP RESISTANCE KCED DESOPXE.PXE w/ 1" THICK SPRAY INSULATION

GWB MOISTURE RESISTANT GYPSUM BOARD

YRREHC REVIR87-7397TRANOSLIWETANIMAL1-LP LAMINATE IN FINE GRAIN FINISH

06-0751TRANOSLIWETANIMAL2-LP LAMINATE IN MATTE FINISH

POR-1 PORCELAIN FLOOR TI ACILIS192VAELLIVSSORCEL BASALT; 12" x 24" TILES

I ENROBRETAW CEPS OCEREVOC DUOLC558EROOM NIMAJNEBTNIAP LLAW1-TP NTERIOR LATEX PAINT; EGGSHELL FINISH N374 C ENRUOBRETAWECAL YLLITNAHC56-COEROOM NIMAJNEBTNIAP GNILIEC4-TP EILING PAINT 508; FLAT FINISH

PTB-1 PORCELAIN TILE WA ACILIS192VAELLIVSSORCESAB LL BASALT; 6" x 12" COVE BASE IEH "4 ;ESAB LLAW DETARGETNI-ROLOCNORI2GNORTSMRAESAB REBBUR1-BR GHT WITH STANDARD TOE

ERC LARUTANLARUTAN DOOWTIURF170PTGNORTSMRAELIT LYNIV YRUXUL1-FR ATIONS ARBORART; 6" x 48" PLANKS ROOLF NACIREMATAM DESSECERMR /OSSERPSEELLIRG DESSECER "61/7STAM RG DESSECER "61/7DEZIDONA KCALB ILLE MAT; LEVEL BSE FRAME; CARPET INSERTS w/ BLACK ADONIZED RAIL

ETERCNOC DELAES1-CS WITH EPOXY COATING

AZNOM602MSYSUAH GLECAFRUS DILOS1-SS HI-MACS ACRYLIC SOLID SURFACE

OBRETAW CEPS OCERETWEP EREVER271-CHEROOM NIMAJNEBTNIAP LLAW2-TP RNE INTERIOR LATEX PAINT; EGGSHELL FINISH N374 EPS OCENIATNUOM NORI03-4312EROOM NIMAJNEBTNIAP EMARF & ROOD3-TP C WATERBORNE INTERIOR LATEX PAINT; SEMI-GLOSS FINISH N376

AWBUS 36G 619 AXIRTEMMYSETILRAMCITSALP DECROFNIER SSALGREBIFPRF FFA '4 OT LLATSNIENILEROCS KCALB /W ETIHW ELIT Y

EZNORB KRAD861TCARTNOC FWSSDNILB WODNIWBW

RP NORTNARCSNOITITRAP TELIOTPT EGNARO( ETERCNOCSREDIH YNIHSTCUDO PEEL)

NOTES

1. PROVIDE WALL TILE (CT-1) ON WALLS TO CEILING.

2. MOISTURE RESISTANCE GYPSUM BOARD SHALL BE PROVIDED IN THE RESTROOMS

3. PAINT ALL METAL DOORS AND DOOR FRAMES PT-3.

4. NORTH, SOUTH, EAST, AND WEST AS NOTED ON THE ROOM FINISH SCHEDULE SHALL BE IN ACCORDANCE WITH PLAN

NORTH AS INDICATED ON THE ARCHITECTURAL FLOOR PLANS IN THIS DRAWING SET.

5. PAINT ALL INTERIOR WALL AND CEILING MOUNTED ITEMS SUCH AS VENTS, GRILLE COVERS & FIRE EXTINGUISHER CABINET FACES & FRAMES. LIGHT FIXTURE TRIM RINGS, STC TO MATCH SURFACE COLOR ON WHICH THEY APPEAR.

6. RE: ARCH FOR WALL TYPES AND CONSTRUCTION.

7. PROVIDE CORNER GUARDS (CG) AT ALL EXTERIOR CORNERS IN ADMIN AREA.

8. RE: ARCH FOR CEILING TYPES AND HEIGHTS.

9. PROVIDE WINDOW BLINDS (WB) AT ALL EXTERIOR WINDOWS IN ADMIN AREA.

W

G

-1 9-

B-

5'

- 0

3"

SIGN SIZE

VARIES

REFER TO

DETAILS

5'

- 0

SIGN SIZE

VARIES

REFER TO

DETAILS

3"

1. SIGN SHALL BE INSTALLED ON WALL ADJACENT TO THE LATCH SIDE OF THE DOOR OR TO THE RIGHT OF THE RIGHT HAND DOOR AT DOUBLE DOORS. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE OF A SINGLE DOOR OR TO THE RIGHT SIDE OF DOUBLE DOORS, SIGNS SHOULD BE ON THE NEAREST ADJACENT WALL. CHARACTER. MOUNTING HEIGHT SHALL

BE 48" A.F.F (MIN.) TO 60" A.F.F. (MAX.) UNLESS OTHERWISE NOTED.

2. TACTILE CHARACTERS SHALL BE SANS SERIF AND SHALL BE ACCOMPANIED BY GRADE II BRAILLE. TACTILE CHARACTERS SHALL BE RAISED 1/32" MIN. ABOVE THEIR BACKGROUND. CHARACTERS SHALL BE 5/8" MIN. AND 2" MAX.

3. PICTOGRAMS SHALL HAVE A HEIGHT OF 6". CHARACTERS OR BRAILLE SHALL NOT BE IN THE PICTOGRAM FIELD. WHERE TEXT DISCRIPTORS FOR PICTOGRAMS ARE REQUIRED, THEY SHALL BE DIRECTLY ABOVE OR BELOW THE PICTOGRAM.

4. CHARACTERS AND THEIR BACKGROUNDS SHALL HAVE A NON-GLARE FINISH. CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND, WITH EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT

BACKGROUND.

5. CONTRACTOR TO SUBMIT SIGNAGE TEXT TO GARRISON FOR REVIEW AND APPROVAL PRIOR TO FABRICATION

AND INSTALLATION.

6. ALL SIGNAGE TO BE CONSTRUCTED AND INSTALLED ACCORDING TO DEPARTMENT OF ARMY STANDARDS FOR

SIGNAGE PROVIDED BY DPW.

7. INSTALL EXTERIOR NO SMOKING SIGN WITHIN 10 FEET OF ALL BUILDING ENTRANCES.

SIGN SHALL READ - NO SMOKING WITHIN 50 FEET OF BUILDING.

NOTES

9"

9"

8 1/2"

3" 6"

1 1/2" TACTILE

ROOM NUMBER

WITH BRAILLE

3/4" PRINTED

MESSAGE

HELVETICA NEUE

55 ROMAN

REMOVABLE

END CAPS

9"

9"

3" 6"

1 1/2" TACTILE

ROOM NUMBER

WITH BRAILLE

HELVETICA NEUE

55 ROMAN

PRINTED PAPER

INSERT WITH

ROOM

DESCRIPTION

3/4" PRINTED

MESSAGE

HELVETICA NEUE

55 ROMAN

REMOVABLE

END CAPS

8 1/2"

9"

1' -2

8 1/2"

3"

1 1/2" TACTILE

ROOM NUMBER

WITH BRAILLE

HELVETICA NEUE

55 ROMAN

6" SYMBOL

1" TACTILE ROOM

DESCRIPTION

WITH BRAILLE

HELVETICA NEUE

55 ROMAN

9"

1' -2

8 1/2"

1 1/2" TACTILE

ROOM NUMBER

WITH BRAILLE

HELVETICA NEUE

55 ROMAN

6" SYMBOL

1" TACTILE ROOM

DESCRIPTION

WITH BRAILLE

HELVETICA NEUE

55 ROMAN

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra wn b y:

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e:

C on tra ct

N o.

So lic ita tio n N o.

U .S

. A R

M Y

EN

G

IN

EE

R D

IS

TR

R

PS

O

F

EN

G

IN

EE

R

S

FO

R T

W O

R

TH

, T

EX

AS

R ev ie we d by

US Army Corps of Engineers ®

D

C

B

A

PL

O

T

SC

AL

E:

PL

O

T D

AT

E:

R ev

Sy m bo l

D es cr ip tio n

Tr ac ki ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H As in di ca te d

R E D

RI

VE

R A R

M Y

DE

PO

T, H

O O

KS

, T

EX

A S

FY

D L A

G

EN

ER

A L

P

UR

PO

SE

W

AR

EH

O

U S E

FE

BR

U

AR

Y

Fort Worth District

H . K

IM

BR

O W

, R .I.

D

H . K

IM

BR

O W

, R .I.

D

JE

N

N

IF

ER

A

. D

EW

IT

T, R .A

I-602

SI

G

NA

G

E

SC

H E

DU

L E B.

T

IN

D

EL

L, R

.A

/2

6/

C H

IE

F

AR

C

H

IT

EC

TU

R

AL

S

EC

TI

O

N

INTERIOR SIGNAGE SCHEDULE1

SKRAMEREPYT NGISEMAN MOOR.ON

-ESUOHERAW001

-ESUOHERAW101

-ESUOHERAW201

-ESUOHERAW301

AMOOR .CELE401

ASEITILITU501

ASEITILITU601

AMOOR .LET701

AMOOR REGRAHC YRETTAB801

-MOOR LACINAHCEM901

BECIFFO011

BECIFFO111

AMOOR .CELE211

AMOOR .LET311

AECIFFO411

-ELUBITSEV511

-MOORKAERB611

-EGAROTS ELCYCER711

AMOOR EGAROTS811

2CNEMOW911

AMOOR REKCOLA911

ANAJ021

1CNEM121

AMOOR REKCOLA121

AMOOR .LET221

AMOOR .CELEA221

ASEITILITU321

ASEITILITU421

AMOOR MOCELET721

AMOOR .CELE821

AMOOR MOCELET131

AMOOR .CELE331

AMOOR .CELE531

AMOOR MOCELETA531

AMOOR MOCELET831

AMOOR .CELE931

AMOOR .CELE041

AMOOR MOCELETA041

6" = 1'-0"

SIGN TYPE A1 6" = 1'-0"

SIGN TYPE B2

6" = 1'-0"

SIGN TYPE C13 6" = 1'-0"

SIGN TYPE C24

W

G

-1 9-

B-

1' -6

1'-0"

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra wn b y:

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e:

C on tra ct

N o.

So lic ita tio n N o.

U .S

. A R

M Y

EN

G

IN

EE

R D

IS

TR

R

PS

O

F

EN

G

IN

EE

R

S

FO

R T

W O

R

TH

, T

EX

AS

R ev ie we d by

US Army Corps of Engineers ®

D

C

B

A

PL

O

T

SC

AL

E:

PL

O

T D

AT

E:

R ev

Sy m bo l

D es cr ip tio n

Tr ac ki ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H

'-0

R E D

RI

VE

R A R

M Y

DE

PO

T, H

O O

KS

, T

EX

A S

FY

D L A

G

EN

ER

A L

P

UR

PO

SE

W

AR

EH

O

U S E

FE

BR

U

AR

Y

Fort Worth District

H . K

IM

BR

O W

, R .I.

D

H . K

IM

BR

O W

, R .I.

D

JE

N

N

IF

ER

A

. D

EW

IT

T, R .A

I-603

SI

G

NA

G

E

SC

H E

DU

L E B.

T

IN

D

EL

L, R

.A

/1

1/

C H

IE

F

AR

C

H

IT

EC

TU

R

AL

S

EC

TI

O

N

6" = 1'-0"

SIGN TYPE D1

W

G

-1 9-

B-

P

P P

LO

C

LO

C

LO

C co co co

FS

A

P

A B C D E

GF

WAREHOUSE

WP

WP

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

FA101

R E:

/F

A1

RE: 1/FA102

R E:

/F

A1

RE: 1/FA101

FIRE ALARM AND MASS NOTIFICATION LEGEND

SYMBOL DESCRIPTION

LOC

P

CO

K

FSA

FTR

W

ANTENNA

TAMPER SWITCH

MANUAL PULL STATION. MOUNT AT 48" AFF UNO.

CARBON MONOXIDE DETECTOR. MOUNT AT 16' AFF UNO.

FIRE ALARM/MASS NOTIFICATION TRANSMITTER

FIRE ALARM ANNUNCIATOR PANEL

SMOKE DETECTOR

SMOKE DUCT DETECTOR

WALL MOUNTED COMBINNATION FIRE ALARM & MASS NOTIFICATION

SPEAKER/STROBE. NUMBER INDICATES CANDELA RATING. MOUNT AT 96" AFF

UNO.

LOCAL OPERATING CONSOLE

WALL MOUNTED COMBINNATION FIRE ALARM & MASS NOTIFICATION STROBE.

NUMBER INDICATES CANDELA RATING. MOUNT AT 96" AFF UNO.

KNOX BOX. SEE ACHITECTURAL SHEET.

PENDANT MOUNTED COMBINNATION FIRE ALARM & MASS NOTIFICATION

SPEAKER/STROBE. NUMBER INDICATES CANDELA RATING. PENDANT MOUNT

29'-0" AFF UNO.

D

WP WALL MOUNTED COMBINNATION FIRE ALARM & MASS NOTIFICATION SPEAKER.

WP FOR WEATHERPROOF. MOUNT AT 96" AFF UNO.

COMBINATION FIRE ALARM & MASS NOTIFICATION CONTROL PANELFCP

FLOW SWITCH

POW BOOSTER POWER SUPPLY

TEL. ROOM

ELEC. ROOM

UTILITIES

15cd 15cd

15cd

WW

W

PO

W

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra wn b y:

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e:

C on tra ct

N o.

So lic ita tio n N o.

U .S

. A R

M Y

EN

G

IN

EE

R D

IS

TR

R

PS

O

F

EN

G

IN

EE

R

S

FO

R T

W O

R

TH

, T

EX

AS

R ev ie we d by

US Army Corps of Engineers ®

D

C

B

A

Pl ot

S ca le

Pl ot

D at e:

R ev

Sy m bo l

D es cr ip tio n

Tr ac ki ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H As in di ca te d

2/ 7/

4:

:2

PM

R E D

RI

VE

R A R

M Y

DE

PO

T, H

O O

KS

, T

EX

A S

FY

D L A

G

EN

ER

A L

P

UR

PO

SE

W

AR

EH

O

U S E

FE

BR

U

AR

Y

W

G

-1 9-

B-

Fort Worth District

K.

L

E, P

.E

T.

N

G U

YE

N

D

AR

EN

A

. B R

O W

N , P

.E

FA101

FI

RE

A

LA

RM

M

AS

S

NO

TI

FI

CA

T I

O N

PL

AN

AR

EA

A

Av er y, P

E

Br ow n, P

E

1/16" = 1'-0"1 FIRE ALARM & MASS NOTIFICATION PLAN - AREA A KEYPLAN

A

B

C

D

E

F

G

H

I08 16 3241216

SCALE: 1/16"=1'-0"

1/8" = 1'-0"3 ENLARGED ROOMS 104, 105, 107

04 8 16268

SCALE: 1/8"=1'-0"

GENERAL NOTES:

1. ALL FIRE ALARM DEVICES INSTALLED SHALL BE IN COMPLIANCE WITH NFPA 72, UFC AND ADA

REQUIREMENTS.

2. STROBE INTENSITIES, INDICATED ON THE PLANS, ARE FOR THE CLEAR FIRE ALARM STROBES.

INCREASE CANDELA RATING OF THE AMBER STROBES AS NECESSARY TO MEET NFPA 72

VISIBILITY REQUIREMENTS.

3. SPEAKERS SHALL BE CONNECTED TO TRANSMIT FIRE ALARM NOTIFICATION SIGNALS AND

MASS NOTIFICATION MESSAGES. SPEAKER QUANTITY AND SPACING MAY VARY, PER

MANUFACTURER, TO MEET THE INTELLIGIBILITY REQUIREMENTS.

4. SEE FIRE ALARM MATRIX ON SHEET FA602.

5. SEE FIRE ALARM REMOTE ANNUNCIATOR DETAILS ON SHEET FA604.

6. SEE LOC DETAIL ON SHEET FA603.

7. FIRE ALARM AND MASS NOTIFICATION SYSTEM SHALL BE BE NOTIFIER OR SIMPLEX BRAND

ADDRSSABLE FIRE ALARM & MASS NOTIFICATION PANEL WITH NOTIFIER OR SIMPLEX

COMPATIBLE PERIPHERAL DEVICES.

8. PROVIDE TAMPER SWITCH FOR AUTOMATED EXTERNAL DEFIBRILLATOR (AED). PROVIDE 120V

POWER SUPPLY FOR AED FROM THE NEAREST POWER SOURCE AVAILABLE. SEE ARCH PLAN

FOR AED LOCATION.

PLAN NORTH

P

LO

C

LO

C

LO

C co co co

P

A B C D E

GF

WAREHOUSE

WP

WP

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

FA102

RE: 1/FA102

RE: 1/FA101

R E:

/F

A1

R E:

/F

A1

ELEC. ROOM

TELECOM

ROOM

15cd W W

15cd

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra wn b y:

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e:

C on tra ct

N o.

So lic ita tio n N o.

U .S

. A R

M Y

EN

G

IN

EE

R D

IS

TR

R

PS

O

F

EN

G

IN

EE

R

S

FO

R T

W O

R

TH

, T

EX

AS

R ev ie we d by

US Army Corps of Engineers ®

D

C

B

A

Pl ot

S ca le

Pl ot

D at e:

R ev

Sy m bo l

D es cr ip tio n

Tr ac ki ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H As in di ca te d

2/ 7/

4:

:2

PM

R E D

RI

VE

R A R

M Y

DE

PO

T, H

O O

KS

, T

EX

A S

FY

D L A

G

EN

ER

A L

P

UR

PO

SE

W

AR

EH

O

U S E

FE

BR

U

AR

Y

W

G

-1 9-

B-

Fort Worth District

K.

L

E, P

.E

T.

N

G U

YE

N

D

AR

EN

A

. B R

O W

N , P

.E

FA102

FI

RE

A

LA

RM

M

AS

S

NO

TI

FI

CA

T I

O N

PL

AN

AR

EA

B

Av er y, P

E

Br ow n, P

E

1/16" = 1'-0"1 FIRE ALARM & MASS NOTIFICATION PLAN - AREA B

KEYPLAN

A

B

C

D

E

F

G

H

I

08 16 3241216

SCALE: 1/16"=1'-0"

1/8" = 1'-0"2 ENLARGED ROOMS 127 AND 128

04 8 16268

SCALE: 1/8"=1'-0"

PLAN NORTH

GENERAL NOTES:

1. ALL FIRE ALARM DEVICES INSTALLED SHALL BE IN COMPLIANCE WITH NFPA 72, UFC AND ADA

REQUIREMENTS.

2. STROBE INTENSITIES, INDICATED ON THE PLANS, ARE FOR THE CLEAR FIRE ALARM STROBES.

INCREASE CANDELA RATING OF THE AMBER STROBES AS NECESSARY TO MEET NFPA 72

VISIBILITY REQUIREMENTS.

3. SPEAKERS SHALL BE CONNECTED TO TRANSMIT FIRE ALARM NOTIFICATION SIGNALS AND

MASS NOTIFICATION MESSAGES. SPEAKER QUANTITY AND SPACING MAY VARY, PER

MANUFACTURER, TO MEET THE INTELLIGIBILITY REQUIREMENTS.

4. SEE FIRE ALARM MATRIX ON SHEET FA602.

5. SEE FIRE ALARM REMOTE ANNUNCIATOR DETAILS ON SHEET FA604.

6. SEE LOC DETAIL ON SHEET FA603.

7. FIRE ALARM AND MASS NOTIFICATION SYSTEM SHALL BE BE NOTIFIER OR SIMPLEX BRAND

ADDRSSABLE FIRE ALARM & MASS NOTIFICATION PANEL WITH NOTIFIER OR SIMPLEX

COMPATIBLE PERIPHERAL DEVICES.

8. PROVIDE TAMPER SWITCH FOR AUTOMATED EXTERNAL DEFIBRILLATOR (AED). PROVIDE 120V

POWER SUPPLY FOR AED FROM THE NEAREST POWER SOURCE AVAILABLE. SEE ARCH PLAN

P P P

LO

C

LO

C

LO

C

LOC

co co co co

P

FS

A

P

H J K L M O P

NG

Q

F

L.2 M.8 O.9

WAREHOUSE

WP

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

FA103

RE: 1/FA103

RE: 1/FA104 RE: 1/FA104

RE: 1/FA103

RE: 1/FA109

RE: 1/FA103

UTILITIES

15cd W

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra wn b y:

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e:

C on tra ct

N o.

So lic ita tio n N o.

U .S

. A R

M Y

EN

G

IN

EE

R D

IS

TR

R

PS

O

F

EN

G

IN

EE

R

S

FO

R T

W O

R

TH

, T

EX

AS

R ev ie we d by

US Army Corps of Engineers ®

D

C

B

A

Pl ot

S ca le

Pl ot

D at e:

R ev

Sy m bo l

D es cr ip tio n

Tr ac ki ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H As in di ca te d

2/ 7/

4:

:3

PM

R E D

RI

VE

R A R

M Y

DE

PO

T, H

O O

KS

, T

EX

A S

FY

D L A

G

EN

ER

A L

P

UR

PO

SE

W

AR

EH

O

U S E

FE

BR

U

AR

Y

W

G

-1 9-

B-

Fort Worth District

K.

L

E, P

.E

T.

N

G U

YE

N

D

AR

EN

A

. B R

O W

N , P

.E

FA103

FI

RE

A

LA

RM

M

AS

S

NO

TI

FI

CA

T I

O N

PL

AN

AR

EA

C

Av er y, P

E

Br ow n, P

E

1/16" = 1'-0"1 FIRE ALARM & MASS NOTIFICATION PLAN - AREA C

KEYPLAN

A

B

C

D

E

F

G

H

I

08 16 3241216

SCALE: 1/16"=1'-0"

1/8" = 1'-0"2 ENLARGED ROOM 106

04 8 16268

SCALE: 1/8"=1'-0"

PLAN NORTH

GENERAL NOTES:

1. ALL FIRE ALARM DEVICES INSTALLED SHALL BE IN COMPLIANCE WITH NFPA 72, UFC AND ADA

REQUIREMENTS.

2. STROBE INTENSITIES, INDICATED ON THE PLANS, ARE FOR THE CLEAR FIRE ALARM STROBES.

INCREASE CANDELA RATING OF THE AMBER STROBES AS NECESSARY TO MEET NFPA 72

VISIBILITY REQUIREMENTS.

3. SPEAKERS SHALL BE CONNECTED TO TRANSMIT FIRE ALARM NOTIFICATION SIGNALS AND

MASS NOTIFICATION MESSAGES. SPEAKER QUANTITY AND SPACING MAY VARY, PER

MANUFACTURER, TO MEET THE INTELLIGIBILITY REQUIREMENTS.

4. SEE FIRE ALARM MATRIX ON SHEET FA602.

5. SEE FIRE ALARM REMOTE ANNUNCIATOR DETAILS ON SHEET FA604.

6. SEE LOC DETAIL ON SHEET FA603.

7. FIRE ALARM AND MASS NOTIFICATION SYSTEM SHALL BE BE NOTIFIER OR SIMPLEX BRAND

ADDRSSABLE FIRE ALARM & MASS NOTIFICATION PANEL WITH NOTIFIER OR SIMPLEX

COMPATIBLE PERIPHERAL DEVICES.

8. PROVIDE TAMPER SWITCH FOR AUTOMATED EXTERNAL DEFIBRILLATOR (AED). PROVIDE 120V

PPP

C

LO

C

LO

C

LO

C co co co co

P

H J K L M O P

NG

Q

F

L.2 M.8 O.9

WAREHOUSE

WPWP

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

FA104

RE: 1/FA103

RE: 1/FA104 RE: 1/FA104

RE: 1/FA103

TELECOM

ROOM

ELEC. ROOM

15cd W W 15cd

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra wn b y:

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e:

C on tra ct

N o.

So lic ita tio n N o.

U .S

. A R

M Y

EN

G

IN

EE

R D

IS

TR

R

PS

O

F

EN

G

IN

EE

R

S

FO

R T

W O

R

TH

, T

EX

AS

R ev ie we d by

US Army Corps of Engineers ®

D

C

B

A

Pl ot

S ca le

Pl ot

D at e:

R ev

Sy m bo l

D es cr ip tio n

Tr ac ki ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H As in di ca te d

2/ 7/

4:

:3

PM

R E D

RI

VE

R A R

M Y

DE

PO

T, H

O O

KS

, T

EX

A S

FY

D L A

G

EN

ER

A L

P

UR

PO

SE

W

AR

EH

O

U S E

FE

BR

U

AR

Y

W

G

-1 9-

B-

Fort Worth District

K.

L

E, P

.E

T.

N

G U

YE

N

D

AR

EN

A

. B R

O W

N , P

.E

FA104

FI

RE

A

LA

RM

M

AS

S

NO

TI

FI

CA

T I

O N

PL

AN

AR

EA

D

Av er y, P

E

Br ow n, P

E

1/16" = 1'-0"1 FIRE ALARM & MASS NOTIFICATION PLAN - AREA D

KEYPLAN

A

B

C

D

E

F

G

H

I

08 16 3241216

SCALE: 1/16"=1'-0"

1/8" = 1'-0"2 ENLARGED ROOMS 131 AND 133

04 8 16268

SCALE: 1/8"=1'-0"

PLAN NORTH

GENERAL NOTES:

1. ALL FIRE ALARM DEVICES INSTALLED SHALL BE IN COMPLIANCE WITH NFPA 72, UFC AND ADA

REQUIREMENTS.

2. STROBE INTENSITIES, INDICATED ON THE PLANS, ARE FOR THE CLEAR FIRE ALARM STROBES.

INCREASE CANDELA RATING OF THE AMBER STROBES AS NECESSARY TO MEET NFPA 72

VISIBILITY REQUIREMENTS.

3. SPEAKERS SHALL BE CONNECTED TO TRANSMIT FIRE ALARM NOTIFICATION SIGNALS AND

MASS NOTIFICATION MESSAGES. SPEAKER QUANTITY AND SPACING MAY VARY, PER

MANUFACTURER, TO MEET THE INTELLIGIBILITY REQUIREMENTS.

4. SEE FIRE ALARM MATRIX ON SHEET FA602.

5. SEE FIRE ALARM REMOTE ANNUNCIATOR DETAILS ON SHEET FA604.

6. SEE LOC DETAIL ON SHEET FA603.

7. FIRE ALARM AND MASS NOTIFICATION SYSTEM SHALL BE BE NOTIFIER OR SIMPLEX BRAND

ADDRSSABLE FIRE ALARM & MASS NOTIFICATION PANEL WITH NOTIFIER OR SIMPLEX

COMPATIBLE PERIPHERAL DEVICES.

8. PROVIDE TAMPER SWITCH FOR AUTOMATED EXTERNAL DEFIBRILLATOR (AED). PROVIDE 120V

PP

C

LO

C

LO

C co co co co

P

P

FS

A

P

Q R S T U V W

X Y Z

O.9

WAREHOUSE

WP

WP

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

FA105

RE: 1/FA105

RE: 1/FA106 RE: 1/FA106

RE: 1/FA105

R E:

/F

A1

R E:

/F

A1

TEL. ROOM

122A

ELEC. ROOM

UTILITIES

15cd

W

W

15cd W

15cd PO W

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra wn b y:

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e:

C on tra ct

N o.

So lic ita tio n N o.

U .S

. A R

M Y

EN

G

IN

EE

R D

IS

TR

R

PS

O

F

EN

G

IN

EE

R

S

FO

R T

W O

R

TH

, T

EX

AS

R ev ie we d by

US Army Corps of Engineers ®

D

C

B

A

Pl ot

S ca le

Pl ot

D at e:

R ev

Sy m bo l

D es cr ip tio n

Tr ac ki ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H As in di ca te d

2/ 7/

4:

:3

PM

R E D

RI

VE

R A R

M Y

DE

PO

T, H

O O

KS

, T

EX

A S

FY

D L A

G

EN

ER

A L

P

UR

PO

SE

W

AR

EH

O

U S E

FE

BR

U

AR

Y

W

G

-1 9-

B-

Fort Worth District

K.

L

E, P

.E

T.

N

G U

YE

N

D

AR

EN

A

. B R

O W

N , P

.E

FA105

FI

RE

A

LA

RM

M

AS

S

NO

TI

FI

CA

T I

O N

PL

AN

AR

EA

E

Av er y, P

E

Br ow n, P

E

1/16" = 1'-0"1 FIRE ALARM & MASS NOTIFICATION PLAN - AREA E

KEYPLAN

A

B

C

D

E

F

G

H

I

08 16 3241216

SCALE: 1/16"=1'-0"

1/8" = 1'-0"2 ENLARGED ROOMS 122, 122A, 123

04 8 16268

SCALE: 1/8"=1'-0"

PLAN NORTH

GENERAL NOTES:

1. ALL FIRE ALARM DEVICES INSTALLED SHALL BE IN COMPLIANCE WITH NFPA 72, UFC AND ADA

REQUIREMENTS.

2. STROBE INTENSITIES, INDICATED ON THE PLANS, ARE FOR THE CLEAR FIRE ALARM STROBES.

INCREASE CANDELA RATING OF THE AMBER STROBES AS NECESSARY TO MEET NFPA 72

VISIBILITY REQUIREMENTS.

3. SPEAKERS SHALL BE CONNECTED TO TRANSMIT FIRE ALARM NOTIFICATION SIGNALS AND

MASS NOTIFICATION MESSAGES. SPEAKER QUANTITY AND SPACING MAY VARY, PER

MANUFACTURER, TO MEET THE INTELLIGIBILITY REQUIREMENTS.

4. SEE FIRE ALARM MATRIX ON SHEET FA602.

5. SEE FIRE ALARM REMOTE ANNUNCIATOR DETAILS ON SHEET FA604.

6. SEE LOC DETAIL ON SHEET FA603.

7. FIRE ALARM AND MASS NOTIFICATION SYSTEM SHALL BE BE NOTIFIER OR SIMPLEX BRAND

ADDRSSABLE FIRE ALARM & MASS NOTIFICATION PANEL WITH NOTIFIER OR SIMPLEX

COMPATIBLE PERIPHERAL DEVICES.

8. PROVIDE TAMPER SWITCH FOR AUTOMATED EXTERNAL DEFIBRILLATOR (AED). PROVIDE 120V

PPP

C

LO

C

LO

C

LO

C co co co co

P

PP

P

Q R S T U V W

X Y Z

O.9

WAREHOUSE

WP WP

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

FA106

RE: 1/FA105

RE: 1/FA106 RE: 1/FA106

RE: 1/FA105

R E:

/F

A1

R E:

/F

A1

R E:

/F

A1

R E:

/F

A1

TELECOM

ROOM

ELEC. ROOM

15cd W W

15cd

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra wn b y:

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e:

C on tra ct

N o.

So lic ita tio n N o.

U .S

. A R

M Y

EN

G

IN

EE

R D

IS

TR

R

PS

O

F

EN

G

IN

EE

R

S

FO

R T

W O

R

TH

, T

EX

AS

R ev ie we d by

US Army Corps of Engineers ®

D

C

B

A

Pl ot

S ca le

Pl ot

D at e:

R ev

Sy m bo l

D es cr ip tio n

Tr ac ki ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H As in di ca te d

2/ 7/

4:

:4

PM

R E D

RI

VE

R A R

M Y

DE

PO

T, H

O O

KS

, T

EX

A S

FY

D L A

G

EN

ER

A L

P

UR

PO

SE

W

AR

EH

O

U S E

FE

BR

U

AR

Y

W

G

-1 9-

B-

Fort Worth District

K.

L

E, P

.E

T.

N

G U

YE

N

D

AR

EN

A

. B R

O W

N , P

.E

FA106

FI

RE

A

LA

RM

M

AS

S

NO

TI

FI

CA

T I

O N

PL

AN

AR

EA

F

Av er y, P

E

Br ow n, P

E

1/16" = 1'-0"1 FIRE ALARM & MASS NOTIFICATION PLAN - AREA F

KEYPLAN

A

B

C

D

E

F

G

H

I

08 16 3241216

SCALE: 1/16"=1'-0"

1/8" = 1'-0"2 ENLARGED ROOMS 138 AND 139

04 8 16268

SCALE: 1/8"=1'-0"

PLAN NORTH

GENERAL NOTES:

1. ALL FIRE ALARM DEVICES INSTALLED SHALL BE IN COMPLIANCE WITH NFPA 72, UFC AND ADA

REQUIREMENTS.

2. STROBE INTENSITIES, INDICATED ON THE PLANS, ARE FOR THE CLEAR FIRE ALARM STROBES.

INCREASE CANDELA RATING OF THE AMBER STROBES AS NECESSARY TO MEET NFPA 72

VISIBILITY REQUIREMENTS.

3. SPEAKERS SHALL BE CONNECTED TO TRANSMIT FIRE ALARM NOTIFICATION SIGNALS AND

MASS NOTIFICATION MESSAGES. SPEAKER QUANTITY AND SPACING MAY VARY, PER

MANUFACTURER, TO MEET THE INTELLIGIBILITY REQUIREMENTS.

4. SEE FIRE ALARM MATRIX ON SHEET FA602.

5. SEE FIRE ALARM REMOTE ANNUNCIATOR DETAILS ON SHEET FA604.

6. SEE LOC DETAIL ON SHEET FA603.

7. FIRE ALARM AND MASS NOTIFICATION SYSTEM SHALL BE BE NOTIFIER OR SIMPLEX BRAND

ADDRSSABLE FIRE ALARM & MASS NOTIFICATION PANEL WITH NOTIFIER OR SIMPLEX

COMPATIBLE PERIPHERAL DEVICES.

8. PROVIDE TAMPER SWITCH FOR AUTOMATED EXTERNAL DEFIBRILLATOR (AED). PROVIDE 120V

DNP

LO

C

LO

C

LOCco co co co

P

FS

A

P

Y AAZ BB CC DD EE FF GG HH

WAREHOUSE

WP

WP

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

110cd

FA107

FA107

15cd

RE: 1/FA107

RE: 1/FA108

R E:

/F

A1

R E:

/F

A1

RE: 1/EL107

RE: 1/EL108

W

15cd

UTILITIES PO

W

ELEC. ROOM

W

W

15cd

15cd 135A

TEL. ROOM

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra wn b y:

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e:

C on tra ct

N o.

So lic ita tio n N o.

U .S

. A R

M Y

EN

G

IN

EE

R D

IS

TR

R

PS

O

F

EN

G

IN

EE

R

S

FO

R T

W O

R

TH

, T

EX

AS

R ev ie we d by

US Army Corps of Engineers ®

D

C

B

A

Pl ot

S ca le

Pl ot

D at e:

R ev

Sy m bo l

D es cr ip tio n

Tr ac ki ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H As in di ca te d

2/ 7/

4:

:5

PM

R E D

RI

VE

R A R

M Y

DE

PO

T, H

O O

KS

, T

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.